HomeMy WebLinkAboutTrefelner(5) signed printsElectrical Load Calculations 1425 Living S.F. at 3 VA 4275 watts Two 20 Amp Appliance Ckts. 3000 watts One Laundry Cir. @ 1500 watts 1500 watts One Range 8000 watts One Dishwasher & One Disposal @ 1500 watts each 3000 watts One Microwave @ 2000 watts 2000 watts One Water Heater @ 4.5 kw 4500 watts One Dryer @ 5 kw 5000 watts One Ref. @ 1500 watts 1500 watts Two Baths @ 1500 watts each 3000 watts Total First 10 KVA at 100% Remainder at 40% 35,775 watts 10,000 watts 10,310 watts Total 20,310 watts One AC Heat at 100% 10,000 watts Total 30,310 watts 30,310 W / 240 V = 126.3 Amps Use 200A Service Smoke detectors wired to 120V Bathroom lights Non Switchable, Non GFI Electrical contractor to verify all equipment loads prior to start of construction. Electrical contractor to recalculate electrical schedule if loads are to be modified (3) #2/0 (THW) copper and (1) #4 ground (THW) copper in 2 gals. conduit Panel: 200 A.M.C.B. 1200 Amp 1,6, 3W 40 Circuit Panel 120/240 Volt a.c disc. 5/8" dia. x 10'-0"--1long ground rod 3/4" copper water pipe U F4 L%_/J b 3 i 8'-0 Wall 0 (3) #2/0 (THW) copper and (1) #4 ground (THW) copper in 2" galy. conduit F.P.L. service (if overhead service) (3) #2/0 (THW) copper and (1) #4 ground (THW) copper in 2 gals. conduit F.P.L. service (if underground service) Ktie ground wire to footing rebars Electrical Riser Diagram ELECTRICAL LEDGEND RECESSED LIGHT WITH LENS C4 EXTERIOR & WET LOCATIONS SURFACE MOUNTED LIGHT FIXTURE SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE UNDER CABINET FLUORESCENT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN CEILING FAN EXHAUST FAN OUTLET THERMOSTAT DUPLEX OUTLET - SWITCHED DUPLEX OUTLET 220 V OUTLET SWITCH THREE WAY SWITCH DOOR CHIMES SD SMOKE & CARBON MONOXIDE DETECTOR -[+ TELEVISION -Q TELEPHONE [j] PUSH BUTTON -U DIMMER SWITCH D NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46" A.F.F. ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFCI MUST BE AFCI. Electrical Notes 1. All loads to be checked by a Florida Licensed Electrician 2. All work to meet the National Electrical Code 3. Calculations and panels below are for sizing conduit and overall building load requirements only 4. All conductors to be copper; all insulation to be THHN. Conduit as follows: PVC below ground, Rigid from underground to service box for exterior lights on building; AC, MC, or EMT conduit elsewhere. 5. Ensure min. 36" clear between equipent and disconnects, Typical. 6. Protective ratings shall comply with NEC 110-9 & NEC 110-10 7. Ensure panels have main disconnect at meter pack per NEC 230-70-A-1 TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS U W ~ > —U CU LU Qr- LU ~ ��� LO .0 N o = UoZ N F--� W O N co Q L �R �J LU Z It M 00 nolo C� ..� LL �n CD O N i UJ � I 00 LL J LCL 04 ;+- Q N r` Z U W D ° J 0 w r o a� ct Q) '4-) V ) L!J W ~ > —U CU LU Qr- LU ~ ��� LO .0 N o = UoZ O CD ,- 00 F--� W � N — Q W r` � cu -- 00 nolo � T L!J U Z LU (V o U F--� W C: co W O -- LL � � J O Q � U LL J LI ;+- 4i cn J 1 Z drawn s.l. checked s.l. date 10/26!2020 scale as noted job number 20052 sheet A-5