Ri g ht-S ui te® Uni ve rsa l 2 019 19 .0 .0 1 RS U0 81 01 Page 1
...cuments\Wrightsoft HVAC\Trefelner Residence.rup Calc = MJ8 Front Door faces: W
Job:Project Summary Date:Entire House By:
Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com
Project Information
Chase TrefelnerFor:Roland Court, Fort Pierce, FL 34951
Notes:
Design Information
Fort Pierce, FL, USWeather:
Winter Design Conditions Summer Design Conditions
Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75
Design TD °F28 Design TD °F15Daily range M
Relative humidity %50Moisture difference gr/lb61
Heating Summary Sensible Cooling Equipment Load Sizing
Structure Btuh20979 Structure Btuh17162
Ducts Btuh2368 Ducts Btuh1604Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0
(none)(none)Humidification Btuh0 Blower Btuh0
Piping Btuh0Equipment load Btuh23347 Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load Btuh17828
Method Latent Cooling Equipment Load SizingSimplified
Construction quality Average0Fireplaces Structure Btuh2744
Ducts Btuh1223Central vent (0 cfm)Btuh0
CoolingHeating (none)14251425Area (ft²)Equipment latent load Btuh3968
1339013390Volume (ft³)Air changes/hour 0.230.45 Equipment Total Load (Sen+Lat)Btuh21795
Equiv. AVF (cfm)51100 Req. total capacity at 0.70 SHR ton2.1
Heating Equipment Summary Cooling Equipment Summary
Make Make TraneTradeTradeTRANE
Model Cond 4TTR4025L1AHRI ref Coil TEM6A0B30H21++TDR
AHRI ref 7567541Efficiency100 EFF Efficiency 13.0 EER, 16 SEER
Heating input kW7.0 Sensible cooling Btuh16800Heating output Btuh23783 Latent cooling Btuh7200
Temperature rise °F27 Total cooling Btuh24000Actual air flow cfm800 Actual air flow cfm800
Air flow factor cfm/Btuh0.034 Air flow factor cfm/Btuh0.043Static pressure in H2O0.50 Static pressure in H2O0.50
Space thermostat Load sensible heat ratio 0.83
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Oct-14 18:28:03Right-S ui te® Uni ve rsa l 2 019 19 .0 .0 1 RS U0 81 01 Page 1...cuments\Wrightsoft HVAC\Trefelner Residence.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com
1 Room name Entire House Bedroom 2
2 Exposed wall 144.0 ft 25.0 ft
3 Room height 9.4 ft 9.4 heat/coolft
4 Room dimensions ft146.0x1.0
5 Room area 1424.5 ft²146.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 320 314 1256 686 122 122 489 267
.GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 6 0 213 158 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 498 408 1633 892 113 98 392 214
.GG 10A-m10A-m 1.6701.670 ee 46.7646.76 53.0953.09 48 0 2244 2548 0 0 0 0
1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5052.50 12 0 427 630 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5352.53 15 0 533 788 15 0 533 788
GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5352.53 15 0 548 810 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 235 229 917 501 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 6 6 213 158 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 301 204 818 447 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 52.5652.56 54 0 1920 2838 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 52.5652.56 19 0 658 972 0 0 0 0
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 24 24 262 248 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 1424 1424 2258 1948 146 146 231 200
FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 1424 144 3988 0 146 25 692 0
6 c) AED excursion 0 -149
Envelope loss/gain 17889 13626 2338 1320
12 a)Infiltration 3090 846 537 147
b)Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 3 690 1 230
Appliances/other 2000 0
Subtotal (lines 6 to 13)20979 17162 2875 1697
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 12 9
14 Subtotal 20979 17162 2887 1706
15 Duct loads 11%9%2368 1604 11%9%326 159
Total room load 23347 18766 3212 1866
Air required (cfm)Air required (cfm)800 800 110 80
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Oct-14 18:28:03Right-S ui te® Uni ve rsa l 2 019 19 .0 .0 1 RS U0 81 01 Page 2...cuments\Wrightsoft HVAC\Trefelner Residence.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com
1 Room name Bath Bedroom 3
2 Exposed wall 6.0 ft 31.0 ft
3 Room height 9.4 heat/coolft 9.4 heat/coolft
4 Room dimensions ft60.0x1.0 ft174.0x1.0
5 Room area 60.0 ft²174.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 56 50 202 110 141 141 565 308
.GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 6 0 213 158 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 10A-m10A-m 1.6701.670 ee 46.7646.76 53.0953.09 0 0 0 0 0 0 0 0
1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5052.50 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5352.53 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5352.53 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 38 38 151 82
GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 113 95 380 207
GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 52.5652.56 0 0 0 0 18 0 640 946
GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 52.5652.56 0 0 0 0 0 0 0 0
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 60 60 95 82 174 174 276 238
FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 60 6 166 0 174 31 858 0
6 c) AED excursion -31 157
Envelope loss/gain 676 319 2869 1939
12 a)Infiltration 129 35 665 182
b)Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 1 230
Appliances/other 0 0
Subtotal (lines 6 to 13)805 355 3534 2351
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 14 11 5 4
14 Subtotal 819 366 3540 2355
15 Duct loads 11%9%92 34 11%9%399 220
Total room load 911 400 3939 2576
Air required (cfm)Air required (cfm)31 17 135 110
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Oct-14 18:28:03Right-S ui te® Uni ve rsa l 2 019 19 .0 .0 1 RS U0 81 01 Page 3...cuments\Wrightsoft HVAC\Trefelner Residence.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com
1 Room name Hall 2 Dining
2 Exposed wall 0 ft 10.0 ft
3 Room height 9.4 heat/coolft 9.4 heat/coolft
4 Room dimensions ft28.0x1.0 ft11.0x10.0
5 Room area 28.0 ft²110.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 94 46 184 101
.GG 10A-m10A-m 1.6701.670 ee 46.7646.76 53.0953.09 0 0 0 0 48 0 2244 2548
1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5052.50 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5352.53 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5352.53 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 52.5652.56 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 52.5652.56 0 0 0 0 0 0 0 0
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 28 28 44 38 110 110 174 150
FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 28 0 0 0 110 10 277 0
6 c) AED excursion -3 -190
Envelope loss/gain 44 35 2880 2609
12 a)Infiltration 0 0 215 59
b)Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)44 35 3095 2668
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution -44 -35 0 0
14 Subtotal 0 0 3095 2668
15 Duct loads 11%9%0 0 11%9%349 249
Total room load 0 0 3444 2917
Air required (cfm)Air required (cfm)0 0 118 124
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Oct-14 18:28:03Right-S ui te® Uni ve rsa l 2 019 19 .0 .0 1 RS U0 81 01 Page 4...cuments\Wrightsoft HVAC\Trefelner Residence.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com
1 Room name Kitchen Living Room
2 Exposed wall 11.0 ft 19.0 ft
3 Room height 9.4 heat/coolft 9.4 heat/coolft
4 Room dimensions ft12.0x11.0 ft355.0x1.0
5 Room area 132.0 ft²355.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 103 91 366 200 0 0 0 0
.GG 10A-m10A-m 1.6701.670 ee 46.7646.76 53.0953.09 0 0 0 0 0 0 0 0
1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5052.50 12 0 427 630 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5352.53 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5352.53 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 179 100 401 219
GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 52.5652.56 0 0 0 0 36 0 1280 1892
GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 52.5652.56 0 0 0 0 19 0 658 972
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 24 24 262 248
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 132 132 209 181 355 355 563 486
FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 132 11 305 0 355 19 526 0
6 c) AED excursion -249 676
Envelope loss/gain 1307 762 3690 4494
12 a)Infiltration 236 65 408 112
b)Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 1 230
Appliances/other 2000 0
Subtotal (lines 6 to 13)1543 2826 4098 4835
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 2 1 18 15
14 Subtotal 1544 2828 4116 4850
15 Duct loads 11%9%174 264 11%9%465 453
Total room load 1719 3092 4581 5303
Air required (cfm)Air required (cfm)59 132 157 226
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Oct-14 18:28:03Right-S ui te® Uni ve rsa l 2 019 19 .0 .0 1 RS U0 81 01 Page 5...cuments\Wrightsoft HVAC\Trefelner Residence.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com
1 Room name WIC Master Bedroom
2 Exposed wall 5.0 ft 31.0 ft
3 Room height 9.4 heat/coolft 9.4 heat/coolft
4 Room dimensions ft12.0x5.0 ft215.0x1.0
5 Room area 60.0 ft²215.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 47 47 188 103 141 126 503 275
.GG 10A-m10A-m 1.6701.670 ee 46.7646.76 53.0953.09 0 0 0 0 0 0 0 0
1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5052.50 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5352.53 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5352.53 0 0 0 0 15 0 548 810
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 141 141 565 308
GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 9 9 38 21
GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 52.5652.56 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 52.5652.56 0 0 0 0 0 0 0 0
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 60 60 95 82 215 215 341 294
FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 60 5 138 0 215 31 858 0
6 c) AED excursion -17 -153
Envelope loss/gain 422 168 2853 1555
12 a)Infiltration 107 29 665 182
b)Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)529 197 3518 1737
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 8 6 5 4
14 Subtotal 537 203 3523 1741
15 Duct loads 11%9%61 19 11%9%398 163
Total room load 598 222 3920 1904
Air required (cfm)Air required (cfm)20 9 134 81
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Oct-14 18:28:03Right-S ui te® Uni ve rsa l 2 019 19 .0 .0 1 RS U0 81 01 Page 6...cuments\Wrightsoft HVAC\Trefelner Residence.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com
1 Room name Master Bath Laundry
2 Exposed wall 6.0 ft 0 ft
3 Room height 9.4 heat/coolft 9.4 heat/coolft
4 Room dimensions ft6.0x12.1 ft6.0x9.0
5 Room area 72.5 ft²54.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 10A-m10A-m 1.6701.670 ee 46.7646.76 53.0953.09 0 0 0 0 0 0 0 0
1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5052.50 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5352.53 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 52.5352.53 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 56 50 202 110 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 6 6 213 158 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 52.5652.56 0 0 0 0 0 0 0 0
GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 52.5652.56 0 0 0 0 0 0 0 0
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 72 72 114 99 54 54 86 74
FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 72 6 166 0 54 0 0 0
6 c) AED excursion -33 -6
Envelope loss/gain 695 335 86 68
12 a)Infiltration 129 35 0 0
b)Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)824 370 86 68
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 10 8
14 Subtotal 824 370 95 75
15 Duct loads 11%9%93 35 11%9%11 7
Total room load 917 404 106 83
Air required (cfm)Air required (cfm)31 17 4 4
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Oct-14 18:28:03Right-S ui te® Uni ve rsa l 2 019 19 .0 .0 1 RS U0 81 01 Page 7...cuments\Wrightsoft HVAC\Trefelner Residence.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com
1 Room name Hall 1
2 Exposed wall 0 ft
3 Room height 9.4 heat/coolft
4 Room dimensions ft3.0x6.0
5 Room area 18.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area Load
number (Btuh /ft²-°F)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0
.G 1A-r1om 1.270 n 35.56 26.39 0 0 0 0
.W 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0
.G 10A-m 1.670 e 46.76 53.09 0 0 0 0
1 1 G 1A-r1om 1.270 e 35.56 52.50 0 0 0 0
G 1A-r1om 1.270 e 35.56 52.53 0 0 0 0
G 1A-r1om 1.270 e 35.56 52.53 0 0 0 0
W 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0
G 1A-r1om 1.270 s 35.56 26.39 0 0 0 0
W 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0
G 1A-r1om 1.270 w 35.56 52.56 0 0 0 0
G 1A-r1om 1.270 w 35.56 52.56 0 0 0 0
D 11D0 0.390 w 10.92 10.34 0 0 0 0
C 16X19-0md 0.408 -1.59 1.37 18 18 29 25
F 22A-tpl 0.989 -27.69 0.00 18 0 0 0
6 c) AED excursion -2
Envelope loss/gain 29 23
12 a)Infiltration 0 0
b)Room ventilation 0 0
13 Internal gains:Occupants @ 230 0 0
Appliances/other 0
Subtotal (lines 6 to 13)29 23
Less external load 0 0
Less transfer 0 0
Redistribution -29 -23
14 Subtotal 0 0
15 Duct loads 11%9%0 0
Total room load 0 0
Air required (cfm)0 0
2020-Oct-14 18:28:04
Ri g ht-S ui te® Uni ve rsa l 2 019 19 .0 .0 1 RS U0 81 01 Page 1
...cuments\Wrightsoft HVAC\Trefelner Residence.rup Calc = MJ8 Front Door faces: W
Job:Duct System Summary Date:Entire House By:
Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com
Project Information
Chase TrefelnerFor:
Roland Court, Fort Pierce, FL 34951
CoolingHeating
External static pressure in H2O0.50in H2O0.50
Pressure losses in H2O0in H2O0
Available static pressure in H2O0.50in H2O0.50
Supply / return available pressure 0.250 / 0.250 in H2O in H2O0.250 / 0.250
Lowest friction rate in/100ft0.301in/100ft0.301
Actual air flow cfm800cfm800
Total effective length (TEL)ft166
Supply Branch Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv
Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk
st3115.036.9VlFx0x04.00.3291731911hBath
st3115.044.6VlFx0x07.00.313801103212hBedroom 2
st3115.034.9VlFx0x07.00.3341101353939hBedroom 3
st4135.031.2VlFx0x07.00.3011241182917cDining
st4135.029.0VlFx0x07.00.305132593092cKitchen
st2115.017.9VlFx0x04.00.37644106hLaundry
st1115.027.3VlFx0x07.00.351113782652cLiving Room
st1115.021.9VlFx0x07.00.365113782652cLiving Room-A
st2115.017.1VlFx0x04.00.3781731917hMaster Bath
st2115.015.0VlFx0x07.00.384811343920hMaster Bedroom
st2115.018.7VlFx0x04.00.374920598hWIC
Supply Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk
st3 Peak AVF 276 206 0.313 507 10.0 0x0 VinlFlx
st4 Peak AVF 177 256 0.301 580 9.0 0x0 VinlFlx st1
st1 Peak AVF 334 482 0.301 614 12.0 0x0 VinlFlx
st2 Peak AVF 190 111 0.374 544 8.0 0x0 VinlFlx
2020-Oct-14 18:28:04
Ri g ht-S ui te® Uni ve rsa l 2 019 19 .0 .0 1 RS U0 81 01 Page 2
...cuments\Wrightsoft HVAC\Trefelner Residence.rup Calc = MJ8 Front Door faces: W
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk
rb1 0x 8000 800 0 0 0 0 x0 0 VlFx