HomeMy WebLinkAboutTrefelner - Energy (5)EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 610/15/2020 12:35 PM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: St. Lucie County
St. Lucie County
Chase Trefelner
Trefelner Residence
Street:
City, State, Zip: Fort Pierce , FL , 34951
Roland Court
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Single-family
1
No
1425
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.32 162.92 ft²
SHGC=0.22
Sgl, U=0.37 12.00 ft²
SHGC=0.22
N/A f t ²
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 1425.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 1356.00 ft²
b. Frame - Wood, Adjacent R=11.0 280.00 ft²
c. N/A R=f t ²
10. Ceiling Types
a. Roof Deck (Unvented)R=20.0 1425.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 50 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:1.583 ft.
Area Weighted Average SHGC:0.220
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits CF, Pstat
3
(174.9 sqft.)
(1636.0 sqft.)
(1425.0 sqft.)
(1425.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
24.0 SEER:16.00
Efficiency
k B t u / h r Efficiency
17.0 COP:1.00
f t ² R
6 85
EF: 0.950
Glass/Floor Area: 0.123
Total Proposed Modified Loads:
Total Baseline Loads:
52.94
53.91 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
10-15-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: St. Lucie County
St. Lucie County
1
Chase Trefelner
Trefelner Residence
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle: 0
No
1
1425
3
New (From Plans)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL , 34951
Fort Pierce ,
St. Lucie
Roland Court
Street Address
Comment:
Building Type: User
Cross Ventilation: No
Whole House Fan: No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 1425 13395
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 Bedroom 2 146 1372.4 No 1 1 Yes Yes1 Yes
2 Bath 60 564 No 0 Yes Yes1 Yes
3 Bedroom 3 174 1635.6 No 1 1 Yes Yes1 Yes
4 Hall 2 28 263.2 No 0 Yes Yes1 No
5 Dining 110 1034 No 0 Yes Yes1 Yes
6 Kitchen 132 1240.8 Yes 1 Yes Yes1 Yes
7 Living Room 355 3337 No 1 Yes Yes1 Yes
8 WIC 60 564 No 0 Yes Yes1 Yes
9 Master Bedroom 215 2021 No 1 1 Yes Yes1 Yes
10 Master Bath 72 676.8 No 0 Yes Yes1 Yes
11 Laundry 54 507.6 No 0 Yes Yes1 No
12 Hall 1 19 178.6 No 0 Yes Yes1 No
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 146 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -25 ft Bedroom 2
2 60 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft Bath
3 174 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -31 ft Bedroom 3
4 28 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Hall 2
5 110 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -10 ft Dining
10/15/2020 12:35 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
6 132 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -11 ft Kitchen
7 355 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -19 ft Living Room
8 60 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -5 ft WIC
9 215 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -31 ft Master Bedroom
10 72 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft Master Bath
11 54 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Laundry
12 19 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Hall 1
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Gable or Shed Metal 1502 ft² Medium 0.6 20 18.4______ No238 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 1425 ft² N N0
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented) 0 146 ft² 0.1 Wood______ Bedroom 2 Blown
2 Under Attic (Unvented) 0 60 ft² 0.1 Wood______ Bath Blown
3 Under Attic (Unvented) 0 174 ft² 0.1 Wood______ Bedroom 3 Blown
4 Under Attic (Unvented) 0 28 ft² 0.1 Wood______ Hall 2 Blown
5 Under Attic (Unvented) 0 110 ft² 0.1 Wood______ Dining Blown
6 Under Attic (Unvented) 0 132 ft² 0.1 Wood______ Kitchen Blown
7 Under Attic (Unvented) 0 355 ft² 0.1 Wood______ Living Room Blown
8 Under Attic (Unvented) 0 60 ft² 0.1 Wood______ WIC Blown
9 Under Attic (Unvented) 0 215 ft² 0.1 Wood______ Master Bedroom Blown
10 Under Attic (Unvented) 0 72 ft² 0.1 Wood______ Master Bath Blown
11 Under Attic (Unvented) 0 54 ft² 0.1 Wood______ Laundry Blown
12 Under Attic (Unvented) 0 19 ft² 0.1 Wood______ Hall 1 Blown
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0Bedroom 2 05013 9N Concrete Block - Int Insul 0.40Exterior 122.4 ft² ____
2 4.1 0Bedroom 2 05012 9E Concrete Block - Int Insul 0.40Exterior 113.0 ft² ____
3 4.1 0Bath 0506 9N Concrete Block - Int Insul 0.40Exterior 56.5 ft² ____
4 4.1 0Bedroom 3 05015 9N Concrete Block - Int Insul 0.40Exterior 141.3 ft² ____
10/15/2020 12:35 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
5 4.1 0Bedroom 3 0504 9S Concrete Block - Int Insul 0.40Exterior 37.7 ft² ____
6 4.1 0Bedroom 3 05012 9W Concrete Block - Int Insul 0.40Exterior 113.0 ft² ____
7 4.1 0Dining 05010 9E Concrete Block - Int Insul 0.40Exterior 94.2 ft² ____
8 4.1 0Kitchen 05011 9E Concrete Block - Int Insul 0.40Exterior 103.6 ft² ____
9 4.1 0Living Room 05019 9W Concrete Block - Int Insul 0.40Exterior 178.9 ft² ____
10 4.1 0WIC 0505 9E Concrete Block - Int Insul 0.40Exterior 47.1 ft² ____
11 4.1 0Master Bedro 05015 9E Concrete Block - Int Insul 0.40Exterior 141.3 ft² ____
12 4.1 0Master Bedro 05015 9S Concrete Block - Int Insul 0.40Exterior 141.3 ft² ____
13 4.1 0Master Bedro 0501 9W Concrete Block - Int Insul 0.40Exterior 9.4 ft² ____
14 4.1 0Master Bath 0506 9S Concrete Block - Int Insul 0.40Exterior 56.5 ft² ____
15 11 0Master Bath 412 9W Frame - Wood 0.40.23Garage 112.0 ft² ____
16 11 0Laundry 49 9W Frame - Wood 0.40.23Garage 84.0 ft² ____
17 11 0Living Room 49 9S Frame - Wood 0.40.23Garage 84.0 ft² ____
# Door Type U-Value AreaStorms
DOORS
Ornt Space
Width
Ft In Ft In
Height
1 Insulated .39 24 ft² None______ W Living Room 83
2 Insulated .46 17.8 ft² None______ W Laundry 8682
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 E Low-E Single 0.32 0.22 15.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes2 Y
2 N Low-E Single 0.37 0.22 6.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes3 Y
3 W Low-E Single 0.32 0.22 18.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes6 Y
4 E Low-E Single 0.32 0.22 48.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes7 Y
5 E Low-E Single 0.32 0.22 12.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes8 Y
6 W Low-E Single 0.32 0.22 36.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes9 Y
7 W Low-E Single 0.32 0.22 18.5 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes9 Y
8 E Low-E Single 0.32 0.22 15.4 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes11 Y
9 S Low-E Single 0.37 0.22 6.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes14 Y
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 441 ft² 441 ft² 30 ft 9.4 ft 11______
10/15/2020 12:35 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
1116.2 561.28.000299Wholehouse .1104115.25Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtype BlockSpeed
1 Electric Strip Heat/ COP:1 17 kBtu/hr ______ sys#1None 1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtype BlockSubtype
1 Central Unit/ SEER: 16 24 kBtu/hr c f m 0.7______ sys#1Split 1 Singl
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.95 50 gal 60.9 gal 120 deg None______ None Garage
FSEC
Company Name System Model # Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert # Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply ---- ---- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 85 ft² Attic 20 ft² Default Leakage Attic ( D e f a u l t ) ______ 1 1 ( D e f a u l t )
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting
10/15/2020 12:35 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078
Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878
Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 Bedroom 2
Default(8 lbs/sq.ft. f t ² f t 0.3 Bath
Default(8 lbs/sq.ft. f t ² f t 0.3 Bedroom 3
Default(8 lbs/sq.ft. f t ² f t 0.3 Hall 2
Default(8 lbs/sq.ft. f t ² f t 0.3 Dining
Default(8 lbs/sq.ft. f t ² f t 0.3 Kitchen
Default(8 lbs/sq.ft. f t ² f t 0.3 Living Room
Default(8 lbs/sq.ft. f t ² f t 0.3 WIC
Default(8 lbs/sq.ft. f t ² f t 0.3 Master Bedroom
Default(8 lbs/sq.ft. f t ² f t 0.3 Master Bath
Default(8 lbs/sq.ft. f t ² f t 0.3 Laundry
Default(8 lbs/sq.ft. f t ² f t 0.3 Hall 1
10/15/2020 12:35 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT