Loading...
HomeMy WebLinkAboutTrefelner - Energy (5)EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 610/15/2020 12:35 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: St. Lucie County St. Lucie County Chase Trefelner Trefelner Residence Street: City, State, Zip: Fort Pierce , FL , 34951 Roland Court Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 1425 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.32 162.92 ft² SHGC=0.22 Sgl, U=0.37 12.00 ft² SHGC=0.22 N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 1425.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 1356.00 ft² b. Frame - Wood, Adjacent R=11.0 280.00 ft² c. N/A R=f t ² 10. Ceiling Types a. Roof Deck (Unvented)R=20.0 1425.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:1.583 ft. Area Weighted Average SHGC:0.220 Description Area Insulation Area Insulation Area Insulation Area 15. Credits CF, Pstat 3 (174.9 sqft.) (1636.0 sqft.) (1425.0 sqft.) (1425.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 24.0 SEER:16.00 Efficiency k B t u / h r Efficiency 17.0 COP:1.00 f t ² R 6 85 EF: 0.950 Glass/Floor Area: 0.123 Total Proposed Modified Loads: Total Baseline Loads: 52.94 53.91 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 10-15-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: St. Lucie County St. Lucie County 1 Chase Trefelner Trefelner Residence Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: 0 No 1 1425 3 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , 34951 Fort Pierce , St. Lucie Roland Court Street Address Comment: Building Type: User Cross Ventilation: No Whole House Fan: No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 1425 13395 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 Bedroom 2 146 1372.4 No 1 1 Yes Yes1 Yes 2 Bath 60 564 No 0 Yes Yes1 Yes 3 Bedroom 3 174 1635.6 No 1 1 Yes Yes1 Yes 4 Hall 2 28 263.2 No 0 Yes Yes1 No 5 Dining 110 1034 No 0 Yes Yes1 Yes 6 Kitchen 132 1240.8 Yes 1 Yes Yes1 Yes 7 Living Room 355 3337 No 1 Yes Yes1 Yes 8 WIC 60 564 No 0 Yes Yes1 Yes 9 Master Bedroom 215 2021 No 1 1 Yes Yes1 Yes 10 Master Bath 72 676.8 No 0 Yes Yes1 Yes 11 Laundry 54 507.6 No 0 Yes Yes1 No 12 Hall 1 19 178.6 No 0 Yes Yes1 No # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 146 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -25 ft Bedroom 2 2 60 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft Bath 3 174 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -31 ft Bedroom 3 4 28 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Hall 2 5 110 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -10 ft Dining 10/15/2020 12:35 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 6 132 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -11 ft Kitchen 7 355 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -19 ft Living Room 8 60 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -5 ft WIC 9 215 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -31 ft Master Bedroom 10 72 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft Master Bath 11 54 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Laundry 12 19 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Hall 1 # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Gable or Shed Metal 1502 ft² Medium 0.6 20 18.4______ No238 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 1425 ft² N N0 # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented) 0 146 ft² 0.1 Wood______ Bedroom 2 Blown 2 Under Attic (Unvented) 0 60 ft² 0.1 Wood______ Bath Blown 3 Under Attic (Unvented) 0 174 ft² 0.1 Wood______ Bedroom 3 Blown 4 Under Attic (Unvented) 0 28 ft² 0.1 Wood______ Hall 2 Blown 5 Under Attic (Unvented) 0 110 ft² 0.1 Wood______ Dining Blown 6 Under Attic (Unvented) 0 132 ft² 0.1 Wood______ Kitchen Blown 7 Under Attic (Unvented) 0 355 ft² 0.1 Wood______ Living Room Blown 8 Under Attic (Unvented) 0 60 ft² 0.1 Wood______ WIC Blown 9 Under Attic (Unvented) 0 215 ft² 0.1 Wood______ Master Bedroom Blown 10 Under Attic (Unvented) 0 72 ft² 0.1 Wood______ Master Bath Blown 11 Under Attic (Unvented) 0 54 ft² 0.1 Wood______ Laundry Blown 12 Under Attic (Unvented) 0 19 ft² 0.1 Wood______ Hall 1 Blown WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0Bedroom 2 05013 9N Concrete Block - Int Insul 0.40Exterior 122.4 ft² ____ 2 4.1 0Bedroom 2 05012 9E Concrete Block - Int Insul 0.40Exterior 113.0 ft² ____ 3 4.1 0Bath 0506 9N Concrete Block - Int Insul 0.40Exterior 56.5 ft² ____ 4 4.1 0Bedroom 3 05015 9N Concrete Block - Int Insul 0.40Exterior 141.3 ft² ____ 10/15/2020 12:35 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 5 4.1 0Bedroom 3 0504 9S Concrete Block - Int Insul 0.40Exterior 37.7 ft² ____ 6 4.1 0Bedroom 3 05012 9W Concrete Block - Int Insul 0.40Exterior 113.0 ft² ____ 7 4.1 0Dining 05010 9E Concrete Block - Int Insul 0.40Exterior 94.2 ft² ____ 8 4.1 0Kitchen 05011 9E Concrete Block - Int Insul 0.40Exterior 103.6 ft² ____ 9 4.1 0Living Room 05019 9W Concrete Block - Int Insul 0.40Exterior 178.9 ft² ____ 10 4.1 0WIC 0505 9E Concrete Block - Int Insul 0.40Exterior 47.1 ft² ____ 11 4.1 0Master Bedro 05015 9E Concrete Block - Int Insul 0.40Exterior 141.3 ft² ____ 12 4.1 0Master Bedro 05015 9S Concrete Block - Int Insul 0.40Exterior 141.3 ft² ____ 13 4.1 0Master Bedro 0501 9W Concrete Block - Int Insul 0.40Exterior 9.4 ft² ____ 14 4.1 0Master Bath 0506 9S Concrete Block - Int Insul 0.40Exterior 56.5 ft² ____ 15 11 0Master Bath 412 9W Frame - Wood 0.40.23Garage 112.0 ft² ____ 16 11 0Laundry 49 9W Frame - Wood 0.40.23Garage 84.0 ft² ____ 17 11 0Living Room 49 9S Frame - Wood 0.40.23Garage 84.0 ft² ____ # Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .39 24 ft² None______ W Living Room 83 2 Insulated .46 17.8 ft² None______ W Laundry 8682 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 E Low-E Single 0.32 0.22 15.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes2 Y 2 N Low-E Single 0.37 0.22 6.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes3 Y 3 W Low-E Single 0.32 0.22 18.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes6 Y 4 E Low-E Single 0.32 0.22 48.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes7 Y 5 E Low-E Single 0.32 0.22 12.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes8 Y 6 W Low-E Single 0.32 0.22 36.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes9 Y 7 W Low-E Single 0.32 0.22 18.5 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes9 Y 8 E Low-E Single 0.32 0.22 15.4 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes11 Y 9 S Low-E Single 0.37 0.22 6.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes14 Y # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 441 ft² 441 ft² 30 ft 9.4 ft 11______ 10/15/2020 12:35 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1116.2 561.28.000299Wholehouse .1104115.25Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtype BlockSpeed 1 Electric Strip Heat/ COP:1 17 kBtu/hr ______ sys#1None 1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtype BlockSubtype 1 Central Unit/ SEER: 16 24 kBtu/hr c f m 0.7______ sys#1Split 1 Singl # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.95 50 gal 60.9 gal 120 deg None______ None Garage FSEC Company Name System Model # Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert # Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply ---- ---- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 85 ft² Attic 20 ft² Default Leakage Attic ( D e f a u l t ) ______ 1 1 ( D e f a u l t ) TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting 10/15/2020 12:35 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078 Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 Bedroom 2 Default(8 lbs/sq.ft. f t ² f t 0.3 Bath Default(8 lbs/sq.ft. f t ² f t 0.3 Bedroom 3 Default(8 lbs/sq.ft. f t ² f t 0.3 Hall 2 Default(8 lbs/sq.ft. f t ² f t 0.3 Dining Default(8 lbs/sq.ft. f t ² f t 0.3 Kitchen Default(8 lbs/sq.ft. f t ² f t 0.3 Living Room Default(8 lbs/sq.ft. f t ² f t 0.3 WIC Default(8 lbs/sq.ft. f t ² f t 0.3 Master Bedroom Default(8 lbs/sq.ft. f t ² f t 0.3 Master Bath Default(8 lbs/sq.ft. f t ² f t 0.3 Laundry Default(8 lbs/sq.ft. f t ² f t 0.3 Hall 1 10/15/2020 12:35 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT