Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's (2) RECEIVE--D MM FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation- Residential Performance Method Project Name, DAY RESIDENCE Builder Name: STEVEN F DAY Sreet: 7967 PLANTATION LAKES DRIVES Permit Office: ST LUCIE COUNTY City,State,Zip: PORT ST LUCIE,FL,34986 Permit Number: 1701-0381 Owner. STEVEN DAY Jurisdiction: Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2 1. New construction or existing New(From Plans) 9. Wall Types(2933.3 sqft) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 2709.30 f12 b.Frame-Wood,Adjacent R=11.0 224.00 if 3. Number of units,if multiple family 1 c.N/A R= It? 4. Number of Bedrooms 3 d.N/A R= ftz 10.Ceiling Types (2855.0 sqft.) Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=20.0 2855.00 fe 6. Conditioned floor area above grade(W) 2855 b.N/A R= ft2 z Conditioned floor area below grade(ft2) 0 c.N/A R-- ft 11.Ducts R ftz 7. Windows(604.3 sqfL) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 175 a. U-Factor. Dbl,U=0.65 402.33 ft2 b.Sup: Attic,Ret:Alto,AH:Attic 6 125 SHGC: SHGC=0.25 12.Cooling systems kBtu1hr Efficiency b. U-Factor: SgI,U=0.65 202.00 112 a.Central Unit 30.0 SEER:16.00 SHGC: SHGC=0.25 b.Central Unit 18,0 SEER:16.00 c. U-Factor: N/A 112 SHGC: 13.Heating systems k8tuthr Efficiency d. U-Factor. N/A ft2 a.Electric Strip Heat 27.0 COP:1.00 SHGC: b.Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 2.000 ft. 14.Hot water systems Area Weighted Average SHGC: 0.250 a.Natural Gas Tarildess Cap-I gallons 8. Floor Types (2855.0 sqft.) Insulation Area EF:0.590 a.Slab-On-Grade Edge Insulation R=0.0 2855.00 ft2 b. Conservation features b.N/A R= ftz None c.N/A R= ft2 15.Credits None Total Proposed Modified Loads: 94.11 PA-QS Glass/Floor Area: 0.212 Total Baseline Loads: 95.40Awlt%o I hereby certify that the plans and specifications covered by Review of the plans and 0--TIRE S X - this calculation are in compliance with the Florida Energy specifications covered by this Code calculation indicates compliance with the Florida Energy Code. PRL EY.PA D Before construction is completed Ul DATE: this building will be inspected for compliance with Section 553.908 I hev'a'by certify that this building,as designed,is in compliance Florida Statutes. With the Florida Energy Code. OWNER/AGENT' BUILDING OFFICIAL: DATE: I DATE: .J - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 311412017 9:50 AM EnergyGauge@ USA-FlaRes;2014 Section R405.4.1 Compliant Software Page I of 7 FILE CO PY! FORM R405-2014 PROJECT Title: DAY RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2855 Lot# Owner STEVEN DAY Total Stories: 1 Block/SubDMsion: #of Units: 1 Worst Case: No PlatBook: Builder Name: STEVEN F DAY Rotate Angle: 0 Street: 7967 PLANTATION LA Permit Office: ST LUCIE COUNTY Cross Ventilation: No County. St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: PORT ST LUCIE, Family Type: Single-family FL, 34986 New/Eudsting: New(From Plans) • Comment CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO BEACH MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 MAIN 1934 20453.6 2 MASTER 921 10158.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MUD ROOM 72 676.8 No 0 1 Yes Yes Yes 2 PANTRY 34 319.6 No 0 1 No Yes Yes 3 BEDROOM 2 186 1748A No 0 1 1 Yes Yes Yes 4 BATH 2 60 564 No 0 1 Yes Yes Yes 5 WIC 2 38 357.2 No 0 1 No Yes Yes- 6 CLST 3 18 169.2 No 0 1 No Yes Yes 7 BEDROOM 3 177 1663.8 No 0 1 1 Yes Yes Yes 8 BATH 3 66 620A No 0 1 Yes Yes Yes 9 HALL 46 432.4 No 0 1 Yes Yes Yes 10 GAMEROOM 355 3337 No 0 1 Yes Yes Yes 11 DINING 209 2382.6 No 0 1 Yes Yes Yes 12 KITCHEN 196 2352 Yes 0 1 No Yes Yes 13 GREAT ROOM 396 5068.8 No 0 1 Yes Yes Yes 14 LAUNDRY 81 761.4 No 0 1 Yes Yes Yes 15 M WIC 1 110 1034 No 0 1 Yes Yes Yes 16 MASTER BATH 238 2856 No 0 1 Yes Yes Yes 17 M TOILET 18 169.2 No 0 1 No Yes Yes 18 M ENTRY 70 658 No 0 1 No Yes Yes 19 M LINEN 8 75.2 No 0 1 No Yes Yes 20 M WIC 2 60 564 No 0 1 Yes Yes Yes 21 MASTER SUITE 336 3830.4 No 0 1 1 Yes Yes Yes 3/1412017 9:50 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 7 FORM R405-2014 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 FOYER 81 972 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet I Slab-On-Grade Edge Insulation MUD ROOM 1 It 0 72 ft2 1 0 0 2 Slab-On-Grade Edge Insulation PANTRY 1 ft 0 34 ft2 ___- 1 0 0 3 Slab-On-Grade Edge Insulation BEDROOM 2 14 ft 0 186 ft2 0 0 4 Slab-On-Grade Edge Insulation BATH 2 6 ft 0 60 fl2 ____ 1 0 0 5 Slab-On-Grade Edge Insulation WIC 2 1 ft 0 38 ft2 1 0 0 6 Slab-On-Grade Edge Insulation CLST 3 1 ft 0 18 ft' 1 0 0 7 Slab-On-Grade Edge Insulation BEDROOM 3 13 ft 0 177 ft2 1 0 0 8 Slab-On-Grade Edge Insulation BATH 3 Eft 0 66 ft2 0 0 9 Slab-On-Grade Edge Insulation HALL 4.2 ft 0 46 ft2 1 0 0 10SIab-On-Grade Edge Insulation GAMEROOM 56 ft 0 355 ft2 1 0 0 11SIab-On-Grade Edge Insulation DINING 17 ft 0 209 ft2 1 0 0 12SIab-On-Grade Edge Insulation KITCHEN 1 ft 0 196 ft2 1 0 0 13SIab-On-Grade Edge Insulation GREAT ROOM 18 ft 0 396 ft2 1 0 0 a 14SIab-On-Grade Edge Insulation LAUNDRY 9ft 0 81 ft2 1 0 0 15SIab-On-Grade Edge Insulation M W IC 1 lift 0 110 ft2 ___ 1 0 0 16SIab-On-Grade Edge Insulation MASTER BATH 39.4 it 0 238 ft2 1 0 0 17SIab-On-Grade Edge Insulation M TOILET 1 ft 0 18 ft2 1 0 0 18SIab-On-Grade Edge Insulation M ENTRY 1 ft 0 70 ft2 __ 1 0 0 19SIab-On-Grade Edge Insulation M LINEN 1 ft 0 8 ft2 1 0 0 20SIab-On-Grade Edge Insulation M W IC 2 811 0 60 f12 1 0 0 218Iab-On-Grade Edge Insulation MASTER SUITE 45 ft 0 336 ft2 1 0 0 22SIab-On-Grade Edge Insulation FOYER 911 0 81 ft2 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch. V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 3193 ft2 0 ft2 Light 0.5 No 0.9 No 20 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 2855 ft2 N N FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) MUD ROOM 20 Blown 72 ft' 0.1 Wood 2 Under Attic(Unvented) PANTRY 20 Blown 34 ft2 0.1 Wood 3 Under Attic(Unvented) BEDROOM 2 20 Blown 186 ftZ 0.1 Wood 4 Under Attic(Unvented) BATH 2 20 Blown 60 ftz 0.1 Wood 5 Under Attic(Unvented) WIC 2 20 Blown 38 ft' 0.1 Wood 6 Under Attic(Unvented) CLST 3 20 Blown 18 ftz 0.1 Wood 7 Under Attic(Unvented) BEDROOM 3 20 Blown 177 ftZ 0.1 Wood 8 Under Attic(Unvented) BATH 3 20 Blown 66 ftZ 0.1 Wood 9 Under Attic(Unvented) HALL 20 Blown 46 ftz 0.1 Wood 10 Under Attic(Unvented) GAMEROOM 20 Blown 355 ftz 0.1 Wood 11 Under Attic(Unvented) DINING 20 Blown 209 ftZ 0.1 Wood 12 Under Attic(Unvented) KITCHEN 20 Blown 196 ftz 0.1 Wood 13 Under Attic(Unvented) GREAT ROOM 20 Blown 396 ftz 0.1 Wood 14 Under Attic(Unvented) LAUNDRY 20 Blown 81 ftz 0.1 Wood 15 Under Attic(Unvented) M WIC 1 20 Blown 110 ftZ 0.1 Wood 16 Under Attic(Unvented) MASTER BATH 20 Blown 238 ftz 0.1 Wood 17 Under Attic(Unvented) M TOILET 20 Blown 18 ftZ 0.1 Wood 18 Under Attic(Unvented) M ENTRY 20 Blown 70 ftZ 0.1 Wood 19 Under Attic(Unvented) M LINEN 20 Blown 8 ft, 0.1 Wood 20 Under Attic(Unvented) M WIC 2 20 Blown 60 ftz 0.1 Wood 21 Under Attic(Unvented) MASTER SUITE 20 Blown 336 ftz 0.1 Wood 22 Under Attic(Unvented) FOYER 20 Blown 81 ftz 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 W Exterior Concrete Block-Ed InsLA4UD ROOM 4.1 1 0 9 4 9.3 ftz 0 0 0.5 0 2 N Exterior Concrete Block-Ext Ins8EDROOM 2 4.1 14 0 9 4 130.7 ftz 0 0 0.5 0 3 N Exterior Concrete Block-Ext Insul BATH 2 4.1 6 0 9 4 56.0 ftZ 0 0 0.5 0 4 N Exterior Concrete Block-Ext Ins6EDROOM 3 4.1 13 0 9 4 121.3 ftZ 0 0 0.5 0 5 N Exterior Concrete Block-Ext Insul BATH 3 4.1 6 0 9 4 56.0 ft' 0 0 0.5 0 6 SE Exterior Concrete Block-Ext Insul HALL 4.1 4 3 9 4 39.7 ftZ 0 0 0.5 0 _7 N E tedor Concrete Block-Ext InsGAMEROOM 4.1 21 0 9 4 196.0 ftZ 0 0 0.5 0 8 E Exterior Concrete Block-Ext InstGAMEROOM 4.1 15 10 10 0 158.3 ftZ 0 0 0.5 0 9 S Exterior Concrete Block-Ext InsiSAMEROOM 4.1 18 0 9 4 168.0 ftz 0 0 0.5 0 •10 E Exterior Concrete Block-Ext Insul DINING 4.1 9 0 11 4 102.0 ftZ 0 0 0.5 0 11 S Exterior Concrete Block-Ext Insul DINING 4.1 8 0 11 4 90.7 ftz 0 0 0.5 0 12 E Exterior Concrete Block-Ext InsiGREAT ROO 4.1 18 0 12 8 228.0 ftz 0 0 0.5 0 13 W Exterior Concrete Block-Ext InsuILAUNDRY 4.1 9 0 9 4 84.0 ftz 0 0 0.5 0 14 S Exterior Concrete Block-Ext Insul M WIC 1 4.1 11 0 9 4 102.7 ftZ 0 0 0.5 0 15 N Exterior Concrete Block-Ext InsMASTER BA 4.1 5 0 12 0 60.0 ftZ 0 0 0.5 0 16 E Exterior Concrete Block-Ext InsMASTER BA 4.1 1 0 12 0 12.0 ftz 0 0 0.5 0 17 S Exterior Concrete Block-Ext InsMASTER BA 4.1 15 0 12 0 180.0 ftz 0 0 0.5 0 18 SW Exterior Concrete Block-Ext InsLMASTER BA 4.1 4 3 12 0 51.0 ftz 0 0 0.5 0 3114/2017 9:50 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 7 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below SpaceEt n AreaFraption P-Vnhip _19 W Exterior Concrete Block-Ext InsMASTER BA 4.1 10 0 12 0 120.0 ft2 0 0 0.5 0 20 NW Exterior Concrete Block-Ext InsMASTER BA 4.1 4 3 12 0 51.0 ft2 0 0 0.5 0 21 N Exterior Concrete Block-Ext Insul M W IC 2 4.1 3 0 9 4 28.0 ft2 0 0 0.5 0 22 W Exterior Concrete Block-Ext Insul M WIC 2 4.1 5 0 9 4 46.7 ft2 0 0 0.5 0 23 N Exterior Concrete Block-Ext InsMASTER SUI 4.1 8 0 11 4 90.7 W 0 0 0.5 0 24 E Exterior Concrete Block-Ext Ins06ASTER SUI 4.1 16 0 11 4 181.3 ft2 0 0 0.5 0 25 S Exterior Concrete Block-Ext InsiMASTER SUI 4.1 21 0 11 4 238.0 ft2 0 0 0.5 0 _26 W Exterior Concrete Block-Ext Insul FOYER 4.1 9 0 12 0 108.0 fl2 0 0 0.5 0 27 W Garage Frame-Wood LAUNDRY 11 24 9 4 224.0 ft2 0 0 0.5 0 WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 2 Metal Low-E Single Yes 0.65 0.25 15.0 ft2 2 ft 0 in 1 ft 4 in None None 2 N 3 Metal Low-E Single Yes 0.65 0.25 9.0 ft2 2 ft 0 in 1 ft 4 in None None 3 N 4 Metal Low-E Double Yes 0.65 0.25 20.0 ft2 2 ft 0 in 1 ft 4 in None None 4 N 5 Metal Low-E Single Yes 0.65 0.25 9.0 f1:2 2 ft 0 in 1 ft 4 in None None 5 SE 6 Metal Low-E Double Yes 0.65 0.25 21.3 1`12 2 ft 0 in 1 ft 4 in None None 6 E 8 Metal Low-E Single Yes 0.65 0.25 20.0 fl' 2 ft 0 in 1 ft 4 in None None. 7 E 6 Metal Low-E Double Yes 0.65 0.25 25.0 ft2 2 ft 0 in 1 ft 4 in None None 8 S 9 Metal Low-E Double Yes 0.65 0.25 48.0 ft2 2 ft 0 in 1 ft 4 in None None 9 E 10 Metal Double(Clear) Yes 0.65 0.25 12.0 ft2 2 ft 0 in 1 ft 4 in None None 10 E 10 Metal Lav-E Single Yes 0.65 0.25 36.0 ft2 2 ft 0 in 1 ft 4 in None None 11 S 11 Metal Double(Clear) Yes 0.65 0.25 12.0 ft2 2 ft 0 in 1 ft 4 in None None 12 S 11 Metal Low-E Single Yes 0.65 0.25 36.0 W 2 ft 0 in 1 ft 4 in None None 13 E 12 Metal Low-E Double Yes 0.65 0.25 160.0 ft2 2 ft 0.in 1 ft 4 in None None 14 W 13 Metal Double(Clear) Yes 0.65 0.25 3.0 ft2 2 ft 0 in 1 ft 4 in None None 15 W 13 Metal Low-E Single Yes 0.65 0.25 9.0 ft2 2 ft 0 in 1 ft 4 in None None 16 S 17 Metal Double(Clear) Yes 0.65 0.25 4.0 ft2 2 ft 0 in 1 ft 4 in None None 17 S 17 Metal Low-E Single Yes 0.65 0.25 16.0 ft2 2 ft 0 in 1 ft 4 in None None 18 W 19 Metal Low-E Single Yes 0.65 0.25 12.0 ft2 2 ft0 in 1 ft 4 in None None 19 N 23 Metal Low-E Double Yes' 0.65 0.25 24.0 ft2 2 ft 0 in 1 ft4l in None None 20 E 24 Metal Low-E Single Yes 0.65 0.25 20.0 ft2 2 ft 0 in 1 ft 4 in None None 21 E 24 Metal Low-E Double Yes 0.65 0.25 25.0 ft2 2 ft 0 in 1 ft 4 in None None 22 S 25 Metal Low-E Single Yes 0.65 0.25 20.0 ft2 2 ft 0 in 1 ft 4 in None None 23 W 26 Metal Low-E Double Yes 0.65 0.25 48.0 ft2 2 ft 0 in 1 ft 4 in None None 3/14/2017 9:50 AM EnergyGauge@)USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 7 FORM R405-2014 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 792 ft2 792 ft' 24 ft 9 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 •Wholehouse ProposedACH(50) 000477 3571.4 196.07 368.73 .3481 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 27 kBtu/hr 1 sys#1 2 Electric Strip Heat None COPA 17 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity AIr Flow SHR Block Ducts 1 Central Unit Split SEER:16 30 kBtu/hr 900 cfm 0.8 1 sys#1 2 Central Unit Split SEER:16 18 kBtu/hr 540 cfm 0.8 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless F)derior 0.59 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft' DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool: 1 Attic 6 175 ft' Attic 17 ft= Default Leakage Attic (Default)c(Default)c 1 1 2 Attic 6 125 ftZ Attic 12 ft' Default Leakage Attic (Default)c(Default)c 2 2 3/14/2017 9:50 AMEnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 7 FORM R405-2014 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb Mar Apr May Jun Jul [X]Auge Oct Nov Dec HeatinJan Feb Mar f Apr f May Jun 4 Jul E )Au4 Sep f Oct f X}Nov f X�Dec Venfin Jan Feb Mar [X]Apr [ May Jun [ Jul ]Aug [ 5e [X]Oct [X]Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours " Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 • PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 6B 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 3/14/2017 9:50 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 7 of 7 r FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: DAY RESIDENCE Builder Name: STEVEN F DAY Street: 7967 PLANTATION LAKES DRIVES Permit Office: ST LUCIE COUNTY City,State,Zip: PORT ST LUCIE,FL,34986 Permit Number. 1701-0381 Owner. STEVEN DAY Jurisdiction: Design Location: FL,Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks orjoints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows,skylights and doors The space between window/door jambs and framing and skylights and Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. " The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity Wages. Garage separation. Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight,IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls.Fireplaces shall have gasketed doors 3/14/2017 9:51 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 r FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index,the more efficient the home. • 7967 PLANTATION LAKES DRIVES, PORT ST LUCIE, FL, 34986 f 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 2709.30 ft2 b.Frame-Wood,Adjacent R=11.0 224.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft' 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Roof Deck(Unvented) R=20.0 2855.00 ft2 6. Conditioned floor area(ft2) 2855 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft211.Ducts R ft2 a. U-Factor: Dbl,U=0.65 402.33 fie a.Sup:Attic,Ret:Attic,AH:Attic 6 175 SHGC: SHGC=025 b.Sup: Attic,Ret:Attic,AH:Attic 6 125 b. U-Factor. Sgl,U=0.65 202.00 ft2 SHGC: SHGC=025 12.Cooling systems kBtuthr Efficiency c. U-Factor. N/A ft2 a.Central Unit 30.0 SEER:16.00 SHGC: b.Central Unit 18.0 SEER:16.00 d. U-Factor. NIA ft2 13.Heating systems kBtulhr Efficiency SHGC: a.Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 2.000 ft. b.Electric Strip Heat 17.0 COP:1.00 Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2855.00 ft2 a.Natural Gas EF:0.59 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits None 1 certify that this home has complied with the Florida Energy Efficiency Code for Building TtiE w Construction through the above energy saving features which will be installed(or exceeded) in this home before final inspection. Otherwise,a new EPL Display Card will be completed based on installed Code compliant features. W Buildl3r Signature: Date: t a Address of New Home: City/FL Zip: CSD WE�O *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/14/20179:51 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1