Loading...
HomeMy WebLinkAboutProject Information Job:(17HS009)/D5 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) All plates are 2X4 except as noted. Top chord 2x4 SP#1 Dense 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 9.00 ft from roof edge,RISK CAT 11,EXP& Bot chord 2x4 SP#2 N:B3 2x4 SP#1 Dense: wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 7 Webs 2x4 SP 93 Wind loads and reactions based on MW FRS with additional C&C member design. Lumber value set"'I 3B"uses design values approved 1/30/2013 by ALSC Right end vertical not exposed to wind pressure. Left cantilever is exposed to wind Calculated horizontal deflection is 0.12"due to live Toad and 0.1$"due to dead load. (J)Hanger Support Required,by others (a)Continuous lateral restraint equally spaded on member.Or 1x4#3SR6 SPF-S or better"T'reinforcement.804!0 length of Bottom chord checked for 10.00 psf non-concurrent live load. web member.Attached with 8d Box or Gun(0.113"x25',min.)nails @ 6"oc. MWFRS loads based on trusses located at least 7.50 ft.from roof edge. Deflection meets L/360 live and L1240 total load.Creep increase factor for dead load is 1.50. Provide hanger or special connection at right end of truss for 847 lbs. 16'8" –I T2 W8 12 ,8X10 6 P a o (a) m Ti W7 ' W6 -4X1 ,3X6 I4X5 83 1106(R) - N 3X4(B1 Wi_ =3X6 -s - B2 1-1 1,4".111- 164" I �19-3/ 1'8-11k>9jP6i/1G" 11'10" —"II R=1051# U=90# RL=275/-_611# W=8" R=847# U=228# (Rigid Surface) H=H1 DESC.= D5 SEQ= 961686 PLT.TYP:WAVE ++y�DESIGN CRIIIT-FBC2014RES/rPI-2007FT/RT-20%rowy0(0) QTY=4 TOTAL=4 REV. 16.01.01D.0710.12 SCALE=0.2500 RU56h�Kk: UIRE EXTREME CARE IN FABRICATING.REFERNICSHIPPING,INSTALLING 7ND-9RWMG- O§CSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS.UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27"2017 INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING, BC DL 10.0psf DRWG ''IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, INCCONFORMANCSHALL OT BEE WITH TPI OR FABRICATING.HANDLING,SHIPPING,INSTALLINESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;G BRACING NG OFILURE TO BTRUSSES.DESIGN BC LL LD THE TRUSS IN •DpSf CM Rc.+� ?F'•.,"*-..y. J ,,;.,.M:..,,; wCONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR '.e.�.+".. iLV:Z:� PLATES ARE MADE OF 20M 8/16GA(W,WSSIK)ASTM A653 GRADE 4(160 fW,KtH,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.0psf OIA LEN. 160800 `.f'kiS.c VIVA):1:$L-53S4 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY 1•Z� JOB#;17HS009 "RAX%. 4,0b-u9= INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC, 3.1.53 N.V4 1£;#Y17sn.33:fa4t:'..E DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIGN SHOWN,THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24,0" TYPE MONO BUILDING DESIGNER PER ANSifrPt 1 SEC.2. Job:(17HS009)I D6 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:136(Effective 6/112013) All plates are 2X4 except as noted. Top chord 2x4 SP#2 N:T1 2x4 SP#1 Dense: 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 9.00 ft from roof edge,RISK CAT II,EXP B. Bot chord 2x4 SP#2 N 53 2x4 SP#1 Dense: wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCp)(+/-)=0.18 Webs 2x4 SP#3 Wind Toads and reactions based on MWFRS with additional C&C member design. Lumber value set"13B"uses design values approved 1/30/2013 by ALSC c �a Right end vertical not exposed to wind pressure. f Left cantilever is exposed to wind Calculated horizontal deflection is 0.12"due to live toad and 0.19"due to dead load. r (J)Hanger Support Required,by others Bottom chord checked for 10.00 psf non-concurrent live load. Deflection meets U360 live and 1.1240 total load.Creep increase factor for dead load is 1.50. MWFRS loads based on trusses located at(east 7.50 ft.from roof edge. Provide hanger or special connection at right end of truss for 847 lbs. _1,4" 15'4"' _I T3 1113X4(R) 1114X5 R T2 W7 12 07X6 6 (7 Nm T1 W6 04X12 03X5 14X5 63 =3X$1i3X6 iV =3X4(81 111/1- =3X6 6' y B2 1'4" 15'4" X1'9-3/-4' 11'8-11W1 1j$_ 11'10" —moi 16'8" ` R=1051# U=102# RL=2531-56# W=8" R=847# U=217# (Rigid Surface) H=H1 DESC.= D6SEQ= 961689 PLT.TYP:WAVE 'DFSIG�N}`CRrrr=F8C20I4RESRPb2007FTIRT-2WA(O%yNO) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.2500 TRUSSES REQUIRE EXTREME CARE IN FABRICATING.HANDLING.SHIPPING.INSTALLING AND BRACING. r. REFER Tp$CSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL .�{}.O�Sf REQ 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE Y�K•'`:` i �HLN FOR '+t,',a,.,.:�'�S 'N;}� {;,q INDICATED,MADISON. ICHORD SHALL HSAFETY PROPEIRLY ATTACH D S 7RUCTUIRAL PANELSUAND BOTTOM CHORD SNALL�HAVE A TC DL 15'Qps DATE 01-27-2017 7 y7�, PROPERLY ATTACHED RIGID CEILING. BC DL 10.OpSf DRWG "IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, q�.�T�'y y +I,w INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN Q,Q $f GM ;..,vs;,f¢ ,2'.u.S �R CONFORMANCE WITH TAI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRAC NG OF TRUSSES.DESIGN BC LL P -,,.,,,�M! ";,...r-"-..,„,�� t ,.•�X CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20/18116GA(W,WSSIK)ASTM A653 GRADE 40160(W,WH,SS)GALV.STEEL,APPLY PLATES TO TOT.LD. 55.Opsf O!A LEN. 160BaD tfi"I'X.a Vlwl 911-3324 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DURYAC. 1.25 JOB#:17HS009 522.t3 r,.{,zp�?I jj+� n DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT �2,}$:1�Sx'`<.iuolyra�=:.may�f'.:f3ficde4 DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" TYPE COMN BUILDING DESIGNER PER ANSUTPI 1 SEC.2. Job:(17HS009)/D7 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) All plates are 2X4 except as noted. Top chord 2x4 SP#2 N 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 9.00 fl from roof edge,RISK CAT II,EXP B, Bol chord 2x4 SP#2 N:133 2x4 SP#1 Dense: wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Webs 2x4 SP#3 Wind loads and reactions based on MW FRS with additional C&C member design. Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Left cantilever Is exposed to wind Right end vertical not exposed to wind pressure. S , Bottom chord checked for 10.00 psf non-concurrent live load. Calculated horizontal deflection is 0.12"due to live load and 0.18"due to dead load. �h! MWFRS loads based on trusses located at least 7.50 ft.from roof edge. Deflection meets U360 live and U240 total load.Creep Increase factor for dead load is 1.50. f 13'4" 37 \114X5 R T2 =3X4 W7 W \\\5X6(R T1 12 N 6 to iv W7 W6 -4X12 IT iffl 1113X5 B3 =3X8 1113 6 83X5 1114X5 W2 3X4(B1 W1 _ 62 W2 =3X6 iv I T F=1 LJ Ul 1,4„ I_ 157 B1 �—1'9-3/4" -1'8-1/4„1-1 t162-3116"i 11'8" f 16'6” R=1042# U=116# RL=220/-49# W=8" R=837# U=202# W=6" (Rigid Surface) (Rigid Surface) DESC.= D7 SEQ= 961694 PLT.TYP:WAVE ryDyESSIGNN�CRIT-FBC2014RESRPI-2007FTIRT"20%(O%y0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.3750 fix,•^'<:;.,y REFER 7SHIPPING,INSTALLING ANU UKAUNU. 0 SCSI (BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF 11 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA 22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE • 7'' /,�' 1- LN,MADISON,WI 53719 FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS.UNLESS OTHERWISE TC DL 15.Opsf ) DATE 01-27-2017 -;5.;::.••_-••rtx•,�••_ ;t:>,,_„x.,,� .?:kn INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A ;t,yr �Sltit+ PROPERLY ATTACHED RIGID CEILING. 'IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRWG q '*• INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN ir .-t_• .._=.��.'.�,X.J.�rivt5tS7V CONFORMANCE WITH TPI:OR FABRICATING,HANDLING,SHIPPING,INSTALLING 8 BRACING OF TRUSSES. DESIGN BC LL 0.0psf CM '�..�v ! •;�+✓•"€'�*..;,,;�F'� -%" CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20/18/16GA(W,HISSIK)ASTM A653 GRADE 40/60(W,K(H,SS)GALV.STEEL.APPLY PLATES TO X" 119NA)!?7 33.4i•t EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY TOT•LD. 55.Opsf O/A LEN. 160600 -Sul; :,)Inn-SA a INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 5172.4.W,:15 h r2gg,� DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT 110. .ZPL1,NL3.3hj'/`JE4 R '3 BUILIDIN SHOWN.THE SUITABILITYER S AND USC.2E OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THEDESIGSPACING 24.0" ITYPE HIP M Job:(17HS009)/DB THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) All plates are 2X4 except as noted. Top chord 2x4 SP SS:T2 2x4 SP#2 N: 170 mph wind,15.00 ft mean hgt.ASCE 7-10,CLOSED bldg,not located within 4.50 ft from roof edge,RISK CAT 11,EXP B, Bot chord 2x4 SP SS:B2 2x4 SP#2 IN: wind TC DL=5,0 psf.wind BC DL=5.0 psf.GCpi(+/-)=O.18 3 11; 3 2x4 SP#1 Dense: ri Webs 2x4 SP#3 Wind loads and reactions based on MWFRS with additional C&C member design. Lumber value set"It 313"uses design values approved 1/3012013 by ALSO Right end vertical not exposed to wind pressure, b Calculated horizontal deflection Is 0.13"due to live load and 0.19"due to dead load. Left cantilever is exposed to wind Bottom chord checked for 10.00 psf non-concurrent live load. (a)Continuous lateral restraint equally spaced on member.Or 1x4#3SRB SPF-S or better"T"reinforcement.80%length of web member.Attached with 8d Box or Gun(0.1 13"x2.5",min.)nails @ 6"ac. Deflection meets U360 live and L/240 total load.Creep Increase factor for dead load is 1.50. 11'4* 52" 7 X 6 =-3X4 W w 12 T1 a 6 (% W VZ6 W6 Zo go4l= I113X5 (133) ,3X6 1114X5 II13X6 iV E==l 1 W2 —=3X4(BI W1UW2 =4X5T. U U 1-4" 1571 81 -1 31IM-3116-, 11.81, 1'9-3/4" 1'8-1/4"1 m 11 a —I- 16'6" R=1042# U=131# RL=187/-42#W=8" R--837# U=189# W=6" (Rigid Surface) (Rigid Surface) DESC.= D8SEQ= 961697 PLT,TYP.-WAVE DESiGN CRfr=FSC20I4RESn`PI-200?FT/RT-20%(O%Y 0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.3750 TRUSSES REQUIRE EXTREME CARE IN I-ABRICAUNU,HANDLING,SHIPPING,INSTALLINGAND BRACING, Sl(BU(LDING TC LL 30.Opsf REF COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN MADISON,W153719)FOR SAFETY PRACTICES PRIOR To PERFORMING THEE 01-27-2017 E FUNCTIONS.UNLESS OTHERWISE TC DL 15.Opsf DATE INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING, BC DL I O.Opsf DRWG *IIMPORTANrl FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS,I O.Opsf CM BC LL INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS N CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES.DESIGN CONFORMS WITH APPLICABLE PROVISIONS OF NOS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 201181160A(W,WSSIK)ASTM A653 GRADE 40160(W,KJH,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 160600 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS 1.25 JOB#: 17HS009 PAVK.'M;�)=4990 DURYAC. 512G'.4.VZ 26th—12=Af= DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0 ITYPE HIPM BUILDING DESIGNER,PER ANSI/TPI 1 SEC.2. Job:(17HS009)/D9 THIS DING.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) All plates are 3X5 except as noted. Top chord 2x4 SP#1 Dense 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 4.50 ft from roof edge,RISK CAT 11,EXP B. Bot chord 2x4 SP#2 N:B3 2x4 SP#i Dense: wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Webs 2x4 SP 93 Wind loads and reactions based on MWFRS with additional C&C member design. Lumber value set"1313"uses design values approved 1130/2013 by ALSO Right end vertical not exposed to wind pressure. Left cantilever is exposed to Wind Bottom chord checked for 10.00 psf non-concurrent live load. Deflection meets U360 live and L/240 total load.Creep Increase factor for dead load is 1.50. 94" 7-2- 07X6 12 T1 W6 W6 6 ,-4Xi2 1113X6 -7 W2 C11 =3X4(B1) 1112X4 W2 =_3X6 W1 @ T f-I i ul 1112X4 1112X4 1-4 157 1-9-3/4' 1,8_1/4" I- 311612-3/16" 166, R--1042# U=144# RL=154/-34#W=8" R=8374 U=179#W=6" (Rigid Surface) (Rigid Surface) DESC.= D9SEQ= 961703 PLT.TYP.-WAVE_ DESIGN CRrT.F6C20j4RES/TPI.200?FT1RT-?Z%(0%YDI0) QTY=1 TOTAL=1 AN REV. 16.01.01D.0710.12 SCALE=0.5000 ;MR TRUSSE5 RF(JUIR5 EXTREME CARtz IN FABRICATING.HANDLING.SHIPPING.INSTALLING DBRACING. MIKS1(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF 218 NORTH LEE STR,,SUITE 312,ALEXANDRIA,VA.22314)ANDWTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE DATE 0 PERFORMING THESE LN MADISON,W163719)FOR SAFETY PRACTICES PRIOR E FUNCTIONS.UNLESS OTHERWISE TC DL 15.Opsf 01-27-2017 BOTTOM CHORD SHALL HAVE A IN61CATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BO PROPERLY ATTACHED RIGID CEILING. BC DL I O.Opsf DRWG IMpORTANr* FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, Y INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;AN FAILURE TO BLD THE T USSIN CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES.DESIGN BC LL O.Opsf Cm CONFORMS WITH APPLICABLE PROVISIONS OF NOS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20/18/16GA(W,FUSS/K)ASTM A653 GRADE 40160(W,KJH,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf I O/A LEN. 160600 1'103-190)1,17"M. EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY 'Vk' ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. •25 JOB#:17HS009 X INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER Si2a 2q.W.156 T71MAr_`Sr DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT 11_31RI-RAUITO MIAMI.RL 53COA DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" ITYPE HIPM BUILDING DESIGNER,PER ANSIrrPI 1 SEC.2. Job:(17HS009)/EJ3A THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Sot:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT ll,EXP B,wind TC DL=5.0 psf,wind BC DL=6.0 psf.GCpi(+/-)=0.18 Top chord 2x4 SP#2 N Bot chord 2x4 SP#2 N Wind toads and reactions based on MWFRS with additional G&G member design. Webs 2x6 SP SS:W2 2x4 SP#3: :Lt Level Return 2x4 SP#3: Bottom chord checked for 10.00 psf non-concurrent live load. Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Deflection meets 0360 live and L/240 total load.Creep increase factor for dead load is 1.50. 4 Left end vertical exposed to wind pressure.Deflection meets U360. }�---2'5-3/4"-- R=114# U=43# NAILED 12 6 T1 3X6 03X4 =3X4 s M7 W2 N in ob W1 m N 1112X4 B1 \02X4 �—1'4-3/4" r= 211-1/4" R=321# U=41# RL=145/-121# W=7-1/4" (Rigid Surface) R=54# Rw=112# U=111# NAILED DESC.= EJ3ASEQ= 960819 PLT.TYP:WAVE DESIGN CRIT-f=D aRESMIJ-2007Fr1RT-20%(0%Y00) QTY=3 TOTAL=3 REV. 16.01.01D.0710.12 SCALE=0.5000 •' Rf�)N�3•• INSTALLING TC LL 30.Opsf REF R O CSt(BUILDING COMPONENT SAFETY RE IN INFORMATION),I ING,SHED IN ,SHIPPING,(TRUSS PLATE INSTITUTE,218 NORTH LEE p S53 ALEXANDRIA, I AND WTCAMOD TRUSS COUNCIL OAMERICA, ENTERPRISE -27-2017 LNMADISON,W19)FOR SAFETYPRACTICES PRIOR TO PERFORMING THESE FUNCTIONS.UNLESSO OTHERWISE TC DL 15.Opsf DATE 01 INDICATED, TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. BC DL 1O.OpSf DRWG r i . rm.:11-L ••IMPORTANT'• FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, �p'ry, y gm r�y,�r 57{y INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN BC LL O.Opsf CM CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES.DESIGN PLATES ARE ITH NIAD OF PO/18%6GA(VJ,HISSM)ASTM LE PROVISIONS OF NOSA653 GRADE ONATIONAL S 0(W,WH,IGN SSGALVASTEELTPI.ALPINE APPLY PLATES TOCTOR TOT.Lp. 55.Opsf O/A LEN. 21104 L1iii'�zEACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY 1:lt;h$s#qty 9Jt1 INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 " $IY.{i:f.T7d,2•a?:}T?;Eik?r`t'il:;?� DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT a' $�Lc�xhY`TL'Y?��•rd.£:Eir� DESIIBUILGN SHOWN.THE SUITABILITY ANS NPI I SEC. THIS COMPONENT FOR ANY BUILDING IS HE RESPONSIBILITY OF THE SPACING 24.0" TYPE EJACK Job:(17HS009)/D10 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT II,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. Webs 2x4 SP#3 :Rt Bearing Leg 2x8 SP SS: Right end vertical not exposed to wind pressure. r Lumber value set"138"uses design values approved 1/30/2013 by ALSC Left cantilever is exposed to wind Deflection meets U360 live and U240 total load.Creep Increase factor for dead load is 1.50. Bottom chord checked for 10.00 psf non-concurrent live load. 7,4" 9,2„ 1%4X5 R =3X4 T2 113X4(R) M1 _ I 12 T1 t�V 6 F,;- W3 W W iv =3X6 "v 3X4 W4 W2 v =3X4(B1) W1 6' 1112X4 B1 =3X8 1113X5(R) 1'4" 15'2" 15'10-3/4" 7:1/4" f 16'6" R=1019# U=150# RL=121/-27# W=8" R=848# U=176# W=6" (Rigid Surface) (Rigid Surface) DESC.= D10 SEQ= 961709 PLT.TYP:WAVE ryryDyyEppSIGNN��CRIT-FSC2014REWD'(2007FTW-20%(0%v0(0)CARE[N FABRICATINGQTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.5000 REFEFIR$CSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS,PLATE INSTITUTE, TC LL 30.Opsf REF 1°�•'ta'""• 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE p i LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS.UNLESS OTHERWISE INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A TC DL 15.Opsf DATE 01-27-2017 PROPERLY ATTACHED RIGID CEILING. BC DL 10.Opsf•IMPORTANT' . FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, P DRW G . INCd , 7GCbJp� IN CONFORMANCE WITH TPP OR FABRICATING,HANDLING,SHIPP NG,INSTALLING d BRACING OF TRSHALL NOT BE RESONSIBLE FOR ANY DEVIATION FRM THIS DESIGN;ANY FAILURE TOIUSSES.THELD TRUSS DESIGN BC LL 0.0psf CM CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20/18116GA(W,WSS/K)ASTM A653 GRADE 40160(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 160600 'i` xx(51-m) EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY TALKS mit)V7&4."a INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THISDURFAC1.25 JOB#:17HS009 ,jam+"q-p?.1"A ,T,rct]g�� DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT . . h+ c,LFgj �ygsny�-�� 3� DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" SPEC BUILDING DESIGNER PER ANSI/TPI 1 SEC.2. TYPE Job:(17HS009)/D11 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) All plates are 2X4 except as noted. Top chord 2x4 SP#2 N 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT il,EXP B,wind TC Bot chord 2x4 SP#2 N DL=5.0 psf,wind BC DI-65.0 psf.GCpi(+/-)=0.18 Webs 2x4 SP#3 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Wind loads and reactions based on MW FRS with additional C&C member design. j, Left cantilever is exposed to wind Right end vertical not exposed to wind pressure. / Deflection meets L/360 live and U240 total load.Creep Increase factor for dead load is 1.50. Bottom chord checked for 10.00 psf non-concurrent live load. rL' 5'4-1/2" -i 107-3/16" %4X5 R T2 12 6 T1 W2 W2 W2 W2 v 50 W2 W2 W N W1 bi i 1'3-11/16" 14'8" B1 15'11-11/16" R=120plf U=100plf RL=5plf W=14'8" (Rigid Surface) DESC.= D11 SEQ= 961721 PLT.TYP:WAVE DESIGN CRIT•FBC2014RESlrPI.2007FT/RT=20%(0%yCIO) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.5000 N •' R " yyq N� QF EXTREME CARE IN SHIPPING,INSTALLING AND BRACING. t4 REFER 70 BC SI(BUILDING COTRUSS _R�MPONENT SAFETY INFORMATION),PUBLISHED BY TPI (TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A TC DL 15.Opsf DATE 01-27-2017 PROPERLY ATTACHED RIGID CEILING. BC DL 100 Sf —dr "IMPORTANT' . FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, P DRW G sf f �' t•, 57�yu�;— „i INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN .5r.r.�.. •K•.i..Y`XaJ' CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES. DESIGN BC LL 0.0psf CM CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20/18/16GA(W,H/SS/K)ASTM A653 GRADE 40/60(W,WH,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 16 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 16DA-Z.ANY 'RA' I:^154)974-4990 INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC, 1.25 JOB#:17HS009 a1YG Zf.W.166 TMFAJ­= DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT iR?8c A `1t)Erb's R r £ 33AY42 DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0 GAE L BUILDING DESIGNER PER ANSIITPI 1 SEC.2. TYPE 0 Job:(17HS009)/D12 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 9.00 ft from roof edge,RISK CAT II,EXP B, Top chord 2x4 SP#2 N wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. Webs 2x4 SP#3:W1,W11 2x6 SP SS: f :Rt Level Return 2x4 SP#3: Right end vertical exposed to wind pressure.Deflection meets L/360. Lumber value set"l 3B"uses design values.approved 1/30/2013 by ALSC Right cantilever is exposed to wind f Deflection meets U360 live and 1-/240 total load.Creep increase factor for dead load is 1.50. Bottom chord checked for 10.00 psf non-concurrent live load. MWFRS loads based on trusses located at least 7.50 ft.from roof edge. { 82-3/4" 7'2-3/4" �I =4X5 12 6 �:;- T1 W � 6 �3X4 ,3X4 T1 C W n 3X6 ,3X6 W4 W5 W2 =6X W =2X4(R) =5X 82 =3X8 =3X4 o W1 W9 W11AIN 04 1 B1 1112X4 1112X4 63 113X6(R) 1113 6 R) I 162-1/4" 3 1/A" 3! " 2'11-1/4" I 1 1'4-3/4"_I �--- —P{+-1' { 6'10" 1' a� 3'8-1/4" � � { 15'5-1/2" R=9109 U=161# RL=192/-161# W=7-1/4" R=1008# U=179# W=4" RI id Surface) (Rigid Surface) DESC._ �2 SEQ= 961751 PLT.TYP:WAVE yDyESSIIGNN�CRIWEIC2014RESRPI.2007 FT/RT"20%(0%Y0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.3750 RUSSFS REQUIRE EXTREME CARE IN,REFER TO SCSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 3O.OpSf REF ;.;r�t-•�'"" 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE I.N.MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 .,�,:z:,,:•.,.,,5�'�..yr.;!y�.•:is„u„c.�,z,.,,,,,.,a INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A p PROPERLY ATTACHED RIGID CEILING. IMPORTANT'- FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRW G INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES.DESIGN BC LL O.Opsf CM CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR ee "”' •�++n PLATES ARE MADE OF 20118116GA(W,HISSIK)ASTM A653 GRADE 40/60(W,IVH,SS)GALV.STEEL.APPLY PLATES TO TOT.LD, 55.Opsf O/A LEN. 150508 TMA M4)`7-,1-5:11 X EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY - lt-*A x;W5:4)1778-:S4 0 INSPECTION OF PLATES FOLLOWED BY(0 SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DU R.FAC. 1.25 JOB#:17HS009 ^ygjr�+. .V1 is&1.r2z .=PADRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT "Z}k3PVL5j3 �1 g� r,A DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0” TYPE COMN BUILDING DESIGNER PER ANSIITPI 1 SEC.2. Job:(17HS009)!D13 THIS DWG,PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:138(Effective 611/2013) 170 mph wind,15.00 It mean hgt,ASCE 7-10,CLOSED bldg,not located within 9.00 ft from roof edge,RISK CAT II,EXP B, wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Top chord 2x4 SP#2 N Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional CBC member design. } Webs 2x4 SP#3:W1,W11 2x6 SP SS: :Rt Level Return 2x4 SP#3: Right end vertical exposed to wind pressure.Deflection meets 1-1360. F ' Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Right cantilever is exposed to wind tlf t Deflection meets U360 live and L1240 total load.Creep Increase factor for dead load is 1.50. Bottom chord checked for 10.00 psf nen-concurrent live load. MW FRS loads based on trusses located at least 7.50 ft,from roof edge. 8'0-314" `14„ 7'0-314" _I =4X5 12 6 T1 W6 '3X4 03X4 W T1 `v o '-'`'3X6 0 W5 3X6 W2 W4 .6X W =2X4(R) )R =5X B2 =3X8 =3X4 v I? W9 W11 (V CJ W1 a tV ri 61 1112X4 1112X4 B3 113X6(R} I113 6 R) " 15'2-1/4" 31 1/1 4 ". �3l1 —711-1/4"— 1' 6'10" --9 jP 1 "^ --'—3'8-1/4" ��1'4-314--oqJ 165-1/2" R=910# U=160# RL=191/-159# W=7-1/4" R=1008# U=178# W=4" ((RI id Surface) (Rigid Surface) SEQ= 961761 DE- = D1�3 REV. 16.01.01D,0710.12 SCALE=0.3750 PLT.TYP:WAVE yDyESSIGNN�CRIIT"FBC2014RESITPI-2007FTIRT-20%(0%y0(0) QTY=1 TOTAL=1 .p, REFER O SCSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TP}(TRUSS PLATE INSTITUTE, TC LL 30Apsf REF SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN N61CATED,DISONTOPICHORD SHALL HAVE PROPERFOR SAFETY LY A7TACHEDPERFORMING STRUCTURAL PANELSFUNCTIONS. AND BOTTOM CHORD SMALL HAVE A ISE TC DL 1 5'Q37Sf DATE 01-27-2017 PROPERLY ATTACHED RIGID CEILING, BC DL 10.OpSf DRWG **IMPORTANT'" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, *� ;'1tcr :S INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN BC LL 0•l�(7Sf CM 's,, d'v�as. _ , CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING 8 BRACING OF TRUSSES.DESIGN %11 CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR150508 CJ CJ Q Sf cX ,�.. PLATES ARE MADE OF 20118116GA(W,H/SS/K)ASTM A653 GRADE 40160(W,K(H,SS)GALV,STEEL.APPLY PLATES TO 70T.LD. p O!A LEN. iYIf A Mn 97-0$383 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z,ANY INSPECTION OF PLATES FOLLOWED BY(I)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 " Sl?X>;4"Tfi'. S,f3.1'T3Yc fi3�`.1'"s" DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIGNS OWN.THE UTAABIRPIISEUSZOFTHISCOMPONENTFORANYBUILDING)STHERESPONSIB)L)TYOFTHE SPACING 24.0° TYPE COMM Job:(17HS009)/D14 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 4.50 ft from roof edge,RISK CAT 11,EXP B, Top chord 2x4 SP#2 N:T2 2x6 SP SS: wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. Webs 2x4 SP#3:W1,W12 2x6 SP SS: :Rt Level Return 2x4 SP#3: Right end vertical exposed to wind pressure.Deflection meets L/360. e Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Bottom chord checked for 10.00 psf non-concurrent live load. MWFRS loads based on trusses located at least 7.50 ft.from roof edge. Deflection meets L/360 live and L/240 total load.Creep increase factor for dead load is 1.50. } 7'8-9116" 4T T T 6'8-9/16" T2 ,5X6 =5X6 12 6 F,- T1 W6 3X4 po3X4T1 W 0zz W6 90 3X6 5o3X6 Wffl4 W5 TW2 W =2X4(R) 6X =5X 62 —3X4 =3X4 NS =3X4 o_ W1 W10 W12 V LW 1 B1 1112X4 1112X4 83 113X6(R) 1113 6(R f 15'5-1/2" 211-1/4" 6'10" 3'8-1/4" 1'4-314" R=910# U=146# RL=185/-153# W=7-1/4" R=1008# U=164# W=7-1/4" (Rigid Surface) (Rigid Surface) DESC.= D14 SEQ= 961756 PLT.TYP:WAVE DESIGN CRIT-FBC2014REMPI-2007FT/RT"20%(0%)/0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.3750 yyyyppRN�.J��NQ .. SHIPPING,INSTALLING AND BRACING. REFERI70 SCSI BUILDING L ING COMPONENT SAFETY INFORMATION).ATION PUBIRE EXTREME CARE IN LISHED BY TPI(TRUSS f''•>a,,, )� (T S PLATE INSTITUTE, TC LL 30.Opsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA 22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE '�'T '1 Ir ••''-�,;� LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS.UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. BC DL 100 Sf "IMPORTANT" . FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, P DRW G yY; +y �wy�p INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN �` "51 3. h ++ >•�+•"•=+i CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING 8 BRACING OF TRUSSES. DESIGN BC LL 0.0psf CM r•�=�»,r,�f-y, •°`F•'^+•",,,�r R -"y CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR i + --+• PLATES ARE MADE OF 20118116GA(W,HISSIK)ASTM A653 GRADE 40/60(W,KIH,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.0psf O/A LEN. 150506 TIFTA°iS�3)r:+.NLaU4 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY n STA0 .12 x95::)I_Xa49 1 INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 .112S.14.V,1.1.66 T;.MV DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIIGNS OWN.THE SUI ANSILITY I PIAN EUS2 OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" TYPE COMN Job:(17HS009)/D15 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 9.00 ft from roof edge,RISK CAT ll,EXP B, Top chord 2x4 SP#2 N wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MW FRS with additional C&C member design. Webs 2x4 SP#3:W1 2x6 SP SS: (J)Hanger Support Required,by others Lumber value set"138"uses design values approved 1/30/2013 by ALSC „a Bottom chord checked for 10.00 psf non-concurrent live load. c Deflection meets U360 live and L/240 total load.Creep increase factor for dead load is 1.50. MWFRS(cads based on trusses located at least 7.50 ft.from roof edge. Provide hanger or special connection at right end of truss for 923 lbs. j� 6'0-3/4" 4'4" 510-1/2" 1114X5 R T2 1114X5(R) 3X4 12 6 T1 W6 3X4 W T3 W6 0 d ,3X6 W4 W5 3X4 W2 _5 W9 T 5X8 W10 cO =3X4 B2 =3X4 ,; C?o W1 W Li _v 1112X4 B3 1113X6(R) 1113X6(R) B1 1112X4 � 16'3-1/4" q 3/4" I� ;:12'11-1/4"-- —1' 6'10" 1 T 4,6„ R=961# U=170# RL=92/-94# W=7-1/4° # U=163# (Rigid Surface) H=R=92323 DESC.= D15 SEQ= 961764 PLT.TYP:WAVE yDyESSIGNHANDLING,SHIPPING,INSTALLING ANDBRACING. �CRIT-FBC2014RESfrF4.2007FT/RT-20%(O%v0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.5000 REFER TO SCSI(BUILDING COMPONENT SAFETY INFORMATION),PUBTRUSSES REQUIRE EX I REME CARE IN LISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA 22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE yyv;� 't•./ `' ;�y7 LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 ,f�r.41..•::•.,-._.._.,_..i;,,.,-,;, ;,,,.,,:;,i+,i,,q INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. ::YYCC "IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRWG yy.. ry+y���1. •� T INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN d ' +� = CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES. DESIGN BC LL O.Opsf CM "`=•°.,,,,T ^{``'+•:..;µ "•`:;�% CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR '^^'^^'�- •^^�- 'r•� PLATES ARE MADE OF 20118/16GA(W,H/SS/K)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT,LD• 55.Opsf O/A LEN. 160304 •IlfS a VIVPI51'a"-3w3 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY 9AXI VZO In -090 INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 317.3 X.W' 66 iP�3 F DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT a. g,•(gt7�y :,� .� ;,;yam DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" TYPE COMN BUILDING DESIGNER PER ANSI/TPI 1 SEC.2. Job:(17HS009)/D16 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) Special loads --(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) Top chord 2x4 SP#2 N TC-From 94 plf at-1.40 to 94 pif at 3.18 Bot chord 2x4 SP SS TC-From 46 plf at 3.18 to 46 plf at 5.93 Webs 2x4 SP#3:W1 2x6 SP SS: TC-From 46 plf at 5.93 to 46 plf at 8.53 3a° :Lt Level Return 2x4 SP#3::Rt Level Return 2x4 SP#3: TC-From 46 pif at 8.53 to 46 pif at 11.28 s fes' TC-From 94 pif at 11.28 to 94 plf at 15.85 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC BC-From 20 pif at 0.00 to 20 plf at 3.08 BC-From 10 pif at 3.08 to 10 plf at 11.38 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 4.50 ft from roof edge,RISK CAT II,EXP B, BC-From 20 plf al 11.38 to 20 pif at 14.46 wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 TC-133.47 Ib Conc.Load at 3.08,11.38. TC-152.54 Ib Conc.Load at 3.70,10.76 Wind loads and reactions based on MWFRS. TC-180.19 ib Conc.Load at 5.92,8.54 TC-191.67 Ib Cone.Load at 6.50,7.96 End verticals exposed to wind pressure.Deflection meets U360. BC-65.89 Ib Conc.Load at 3.08,11.38 BC_73.54 Ib Conc.Load at 3.70,10.76 Bottom chord checked for 10.00 psf non-concurrent live load. BC_108.50 Ib Conc.Load at 5.92,8.54 Deflection meets U360 live and U240 total load.Creep increase factor for dead load is 1.50. BC_102.74 Ib Conc.Load at 6.50,7.96 32-1/8" 2'9-1/16" -27-1/8"- -2'9-1/16" 32-1/8"-s{ 12 3.83 C::--- U T2 %4X5(R) T3 ///4X5(R) T2 12 5X6 5X6 6 T1 JW4 T1 o 4X6 W 3 '4X6 io T `7 Iq r 3X4 W4 3X4 W M1 3X4 W3W2 =3X4 '.�T T f1V W1 W1 Li LW I1 =3X6 1112X4 1112X4 =3X6 13X6 81 1113X f 14'5-1/2" 1 - � R=1720# U=4509 W=7-1/4" R=1720# U=450# W=7-1/4" (Rigid Surface) (Rigid Surface) DESC.= D16 SEQ= 961854 PLT.TYP:WAVE �yDyEpSIIGNN�CRIT-FBC2014RESITPI-2007FTIRT=20%(0%y0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.3750 s an•• REFER 7SHIPPING,INSTALLING A D BRACING. 0$CSI(TRU58FS REQUIRE EXTRFMF CARE IN FABRICATING.BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 3O.OPSf REF """ P.''.o., 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE n�;,;Y� ,•:`IjY/ '"�y LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS.UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A qp,,i•���.� PROPERLY ATTACHED RIGID CEILING. BC DL 1 0.0 Sf aS•`..dSYttt,y.i' IMPORTANT' FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, p DRW G 7k INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN �Q•G;•�'� '0'�•�-• _ CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING 8 BRACING OF TRUSSES.DESIGN BC LL 0.0psf CM �''�� �. ,;�" '+."a•".,...N ,"j1, CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20/18116GA(W,HISS/K)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 140508 ''MIA(954):17?'r3'.?f.4 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY x"AXI;1056.)t7W.990 INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DU R.FAC. 1.25 JOB#:17HS009 -712G_nT-W;3*lh Tr, MA.!=c DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT 1%L1&rLsr�NZ) � '" DESIGN NSHOWN. THE SUITANSUTYANDUSE OFTHIS COMPONENT FOR ANY BUILDING ISTHE RESPONSIBILITY OFTHE SPACING 24.0" N)7E COMN Job:(17HS009)/D17 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value.Set:13B(Effective 6/1/2013) All plates are 3X4 except as noted. Top chord 2x4 SP#2 N:T2 2x4 SP#1 Dense: 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 9.00 ft from roof edge,RISK CAT II,EXP B, Bot chord 2x4 SP#2 N wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Webs 2x4 SP#3:W1 2x6 SP SS: :W5 2x4 SP#1 Dense::W7 2x4 SP#2 N: Wind loads and reactions based on MWFRS with additional C&C member design. N rc x :Lt Level Return 2x4 SP 93: by others Lumber value set"138"uses design values approved 1/30/2013 by ALSC (J)Hanger Support Required, F,r'�• Left end vertical exposed to wind pressure.Deflection meets U360. Bottom chord checked for 10.00 psf non-concurrent live load. least 15.00 it.from roof edge. MWFRS loads based on trusses located as Deflection meets U360 live and L/240 total load.Creep increase factor for dead load is 1.50. )— 8'0-3/4" Pmvodd hanym VO3 I:eciat%+nnection at right end of truss for 861 lbs. 3'0-3/4" 6'6-1/4" 1-r3/L" r 5'6-1/2" T3 ,5X6 T2 i2X4 4X5 12 PZ 6 F7,- T1 1112X4 T4 3X6 c? T W3 W v I � " W7 o T W5 W 4 CO M1 W2 N W1 =6X W N B2 1113X5 1EEEH= Li 1113X6 =3X8 B1 1112X4 L 15'3-1/4" 1'4-3/4" + 12'9-1/4" 1 R=998# U=111# RL=113/-148# W=7-1/4" R=861# U=62# (Rigid Surface) H=H1 DESC.= D17 SEQ= 961773 PLT.TYP:WAVE yDyESSIGNN� F CRIT-FBC2014RESNPI.2007T/RT=20%(0%%0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.5000 REFER7SHIPPING,INSTALLING AND BRACING. 0$CSI(BUILDING COMPONENT SAFETY INFORMATION),PUBUIRE ERM"EML:CARE IN LISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF ? 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE -""'''• LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS.UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A Sr•,y! �», ,.� PROPERLY ATTACHED RIGID CEILING. BC DLI 0.0 Sf TB "�'�t>•�v�a_S= 'a 'IMPORTANT' FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, P DRW G INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES.DESIGN BC LL O.Opsf CM f s•'•"•"^^>..,,a 't CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR �� Ate••'• PLATES ARE MADE OF 20118/16GA(W,WSSM)ASTM A653 GRADE 40!60(W,WH,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 150304 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-7-ANY rt.`I !.11954) INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 i12G Z4.v&16T.fr 22.F313`Aj_" DRAWING IN ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT I13.e?P,c1xN45 Z3F�_e'`a,pS.33W DESIGN GN SHOWN. NERTHE SUITABILITY AND 2USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" ITYPE COM N Job:(17HS009)/D18 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:138(Effective 6/1/2013) Special loads --(Lumber Dur.Fac=1.25/Plate Dur.Fac=1.25) Top chord 2x4 SP#2 N TC-From 94 pif at-1.40 to 94 pif at 1.06 r Bot chord 2x4 SP#2 N TC-From 47 pif at 1.06 to 47 pif at 3.13 /7. Webs 2x4 SP#3:W1 2x6 SP SS::W8 2x4 SP#2 N: TC-From 94 plf at 3.13 to 94 pif at 6.06 :Lt Level Return 2x4 SP#3: TC-From 94 pif at 6.06 to 94 plf at 9.02x, TC-From 94 plf at 9.02 to 94 plf at 15.27 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC BC-From 10 pif at 0.00 to 10 plf at 3.13 ` Left end vertical exposed to wind pressure.Deflection From 20 pif at 3.13 to 20 pif at 13.77on meals L/360. BC-From 20 pif at 13.77 to 20 pif at 15.27 TC--8.38 Ib Conc.Load at 1.09 TC--3.22 Ib Conc.Load at 3.13 BC-31.64 Ib Conc.Load at 1.09 BC-13.80 Ib Conc.Load at 3.13 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT 11,EXP B.wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. (J)Hanger Support Required,by others Page overflow in note placement.(RdNot) 1'0-3/ " 2'11-1/2" 5' E 6'3"12 -� T4 6 T2 T3 1114X5 2 C4 3X4(R) T1 1114X5(SRS)(R) W T 1114X5 R 3X423X6 W6 W8 v T T 23X4 W WS 10 I� 21�. 2'4 6 W3 .,I(L 3X5 8. =3X8 81 =3X8 =bAb 1112X4 B2 1113X5 I n 163-1/4" 1'4-3/4+ 12'9-1/4" _I�1-6yl R=917# U=346# RL=39# W=7-1/4" R=849# U=180# (Rigid Surface) H=H1 DESC.= D18 SEQ= 961785 PLT.TYP:WAVE DESIGN CRR-MC2014RESNP1.2007FT/RT"20%(0%y0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.1875 yyyyppRNN��Np" INSTALLING AND BRACING. REFER TO SCSI BUILDING COMPONENT SAFETY INFORMATION PUBLISHED LISHED BY TPI RUBS PLATE INSTITUTE.), (rTRUSSES RE DIRE EXTREME CARE IN FABRICATING,HANDLING, ur . TC LL 30.Opsf REF ��� i)Y'j'�•�_ 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA 22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A yy�,,rgiry PROPERLY ATTACHED RIGID CEILING. " BC DL 10.0Sf IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, P DRW G ��m ;� INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN �".,-tom' CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING 8 BRACING OF TRUSSES. DESIGN BC LL O.Opsf CM CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20M811603A(W,H/SS/K)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 150304 eXZA VwI 91r?1332-1 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-2.ANY �1'lw<z X54197&. 911 INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 32`243:4.V4.161h TAIIF„� DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIGN SHOWN. OWN.THE SUITABILITY ANSI PI A 2 NDUSE OFTHIS COMPONENT FOR ANY BUILDING ISTHE RESPONSIBILITY OFTHE BUILDING SPACING 24.0" ITYPE COMN Job:(17HS009)/E1 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,18.54 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT 11,EXP B,wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Top chord 2x4 SP#2 N:T2 2x6 SP SS: Bot chord 2x4 SP#2 N Wind loads and reactions based on MW FRS. Ji Webs 2x4 SP#3 �t! Left and right cantilevers are exposed to wind p - Lumber value set"13B"uses design values approved 1/30/2013 by ALSC #t hip supports 4-2-0 jacks W/2 pane!TC and no end vert. _ Left side jacks have 4-2-0 setback with 1.4-0 cant and 0-0-0 overhang.End jacks have 4-2-0 setback With 1-4.0 cant and 0-0.0 overhang.Right side jacks have 4-2-0 setback with 1-4.0 cant and 0-0-0 overhang. Deflection meets L/360 live and L/240 total load.Creep increase factor for dead load is 1.50. =5X6 T2 =5X6 12 6 T1 T1 W2 1112X4 1112X4 [V W2 3X4(61) W1 W1 =3X4(81) T 1112X4 1112X4 81 1112X4 1112X4 r!l1'4" 7' 114" 12'4" —J R=672# U=1584 W=8" R=396# U=78# W=8" (Rigid Surface) (Rigid Surface) R=483# U=121# W=6" (Rigid Surface) DESC.= E1SEQ= 960969 PLT.TYP:WAVE DESIGN �CR{T-FBC2614RESrM-2007FT/RT-20%(0%v0(0) QTY=2 TOTAL=2 REV. 16.01.01D.0710.12 SCALE=0.5000 R�R 7q EC5S(BUILDING COMPONENT SAFETY INFORMATION),PUBTRUSSES HI--QU EXTREME CARh IN LISHED BY FIANDLINOSPI(TRUSS PLATE INSTtTUTE,AND BRACING. TC LI- 30.Opsf REF r;>'� W'`5@� 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE ISE INDICATED.MADISON, SHALL HAVE PROPEFOR SAFETY ICES PRIOR TO RLY ATTACHED STRUCTURALNG THESE FUNCTIONS,UNLESS PANELSPANELS AND BOTTOM CHORD SHALL A TC DL 15.OPSf DATE 01-2?-2017 PROPERLY ATTACHED RIGID CEILING. BC DL 10.0PSf DRWG "IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, INC CONFORMANCE SHALL aE W TH TPI:OR FABRICATING,HANT BE RESPONSIBLE FOR ANY DEVIDLING,ATION SHIPP NGFROM THIINSTALLING&BRACING OFDESIGN;ANY FAILURE TOBUILD TRUSSES.THETRUSS DESIGN BC LL O.OPSf GM {{ Nv..•y CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR 55.Opsf."".. uiCv-,.-n.� PLATES ARE MADE OF 20/18116GA(W,WSSIK)ASTM A653 GRADE 40/60(W,KlH,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. P O/A LEN. 12oaoo 'i'fff.r V&S)QTr"nl EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z,ANY 1.25 JOB#:17HS009 :FKr)1�1z 1115.4)h"rLMMID INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DU R.FAC. &12G -ys xry �rm,);p.,�yµi,; DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIGN SHOWN.THE SUTABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE S PACING 24.0" TYPE HIPS BUILDING DESIGNER PER AN 11 1 SEC.2. Job:(17HS009)/E2 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,19.04 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 4.50 ft from roof edge,RISK CAT LI,EXP B, wind TC DL=5A psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Top chord 2x4 SP#2 N Sot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. Webs 2x4 SP#3 , Left and right cantilevers are exposed to wind Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Bottom chord checked for 10.00 psf non-concurrent live toad. Deflection meets U360 live and L/240 total load.Creep increase factor for dead load is 1.50. =4X5 T1 12 6 1112X4 102X4 W3 T1 W2 1112X4 1112X4 W2 3X4(B1) W1 W1 =3X4(B1) 6 ri F1 1112X4 1112X4 g1 1112X4 1112X4 1112X4 7, 2,8" 1,4„ 12'4` -) R=622# U=136# RL=92/-92# W=8" R=348# U=63# W=8" (Rigid Surface) (Rigid Surface) R=499# U=106# W=6" (Rigid Surface) DESC,= E2SEQ= 960986 PLT.TYP:WAVE ry4Dy/ESSIIGNCRIT-FOC2014REWM2007FTlRT"20%(0%)/0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.5000 IRLISSn-REMME EXTREME CARE IN f-ABRICATING.HANDLING,s.. REFERN�O BCSt( INSTALLING AND SPACING. BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.OpSf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE NG THESE r INDICATED.TOPICHORD SHALL 14AVE PROPEFOR SAFETY IRLY ATTACHED STRUCTUCES PRIOR TO RAL PANELS UAND BOTTOM CHORD SHALNCTIONS.UNLESS L�HAVE A ISE TC DL S.OpSf DATE 41-27-2017 PROPERLY ATTACHED RIGID CEILING. SC DL 10.4psf DRWG "IMPORTANr* FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, ;),�1 q Sar •y, ,y INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN BC LL O,OpSf CM CONFORMANCE WITH TPI,OR FABRICATING,HANDLING,SHIPPING,INSTALLING&SPACING OF TRUSSES.DESIGN CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR E-� `"�,alu..""• L.T�"'°"yS'C"'� PLATES ARE MADE OF 20/18116GA(W,HISS(K)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL,APPLY PLATES TO TOT.LD. 55Apsf O!A LEN. 120400 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY C-354)1 >;-o 'il INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#;17HS009 XF'6,rTsTf3PAr_S DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" TYPE COMN BUILDING DESIGNER PER ANSI/TPI 1 SEC.2. Job:(17HS009)!G7 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 4.50 ft from roof edge,RISK CAT II,EXP B, wind TC DL=6.0 psf,wind BC DL--5.0 psf.GCp71(+/-)=018 Top chord 2x4 SP#2 N Bot chord 2x4 SP SS Wind toads and reactions basad on MWFRS with additional C&C member design. r it Webs 2x4 SP#3 �gggg End verticals not exposed to wind pressure. Lumber value set"13B"uses design values approved 1/30/2013 by ALSO (J)Hanger Support Required,by others Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. (J)Hanger Support Required,by others Deflection meets U360 live and U240 total load.Creep increase factor for dead load is 1.50. Bottom chord checked for 10.00 psf non-concurrent live load. Provide hanger or special connection at left end of truss for 543 lbs. Provide hanger or special connection at right end of truss for 544 lbs. 0-_„" 0_ 4„ �; 4'4-114" � 44-114" `- 12 =4X5 6p T1 T1 1112X4 W 1112X4 'N 0 n W2 W1 W1 11 M 11 airz Kqlw 1114X5(R) 61 1114X5(R) 8'10" --'i R=543# U=84# RL=63/-63# R=544# U=84# H=H1 H=H2 DESC.= G1SEQ= 960813 PLT.TYP:WAVE DESIGN CRIT-F502014RESM14007 FT/RT-20%(0%N 0(0) QTY=2 TOTAL=2 REV. 16.01.01D.0710.12 SCALE=0.3750 ++ N� t+' --+•w:. R RRONCSI(BUILDING COMPONENT SAFETY RE IN FATtON),PUBLISHED ING.SHIPPING,TPS(TRUSS PLATE INSTALLING AND TC LL 30.0pSf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS.UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 +• .�A t'=(1'y<' L:%' ---7.� INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND a0TTOM CHORD SHALL HAVE A ,��.,......... .:.:: •..-:.w.,,...::�::M...> BC DL 10.0pSf DRWG PROPERLY ATTACHED RIGID CEILING. q,:{.:"�n �� ••IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, c'�s.FT J,fc s. .T.�. � COINCNFORMANSHALL CE WITH TPT BE p00R FABRINSIBLE CATING,HANR ANY DLING,SHIPPING,INSTALLING&BRACING OFATION FROM THIS DESIGN;ANY FAILURE TO TRUSSES.ILD THE TDESIGN $C LL RUSS NO.Opsf CM CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20/18/16GA^R/SS/K)ASTM A653 GRADE 40160(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Ops O/A LEN. 81000 '.t`k,5`xx ip'm"x;+ '3wEACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY RAV_ 4)97P_*1M INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 OB#:17HS009 r,0 mw.7:53:ft T? iP`1'Ll"�' DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT 3L-7rtil::GTt £.3$1Y,1"t DESIGN SHOWN,THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" TYPE COMN BUILDING DESIGNER PER ANSI/TPI Job:(17HS009)/G2 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 It mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT ll,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 ra 17 Bot chard 2x4 SP#2 N Wind loads and reactions based on MW FRS. -' Webs 2x4 SP#3 r` :Lt Level Return 2x4 SP#3::Rt Level Return 2x4 SP#3: End verticals not exposed to wind pressure. Lumber value set"l 3B"uses design values approved 1/30/2013 by ALSC (J)Hanger Support Required,by others tfry �- #1 hip supports 3-0-0 jacks with no webs. (J)Hanger Support Required,by others Left side jacks have 3-0-0 setback with 0-0-0 cant and 1-4-0 overhang.End jacks have 3-0-0 setback with 0-0-0 cant and Deflection meets U360 live and L/240 total load.Creep increase factor for dead load is 1.50. 1-4-0 overhang.Right side jacks have 3-0-0 setback with 0-0-0 cant and 1-4-0 overhang. Provide hanger or special connection at left end of truss for 677 lbs. Provide hanger or special connection at right end of truss for 677 lbs. 1- 3' I" 2-10" r 3- %A4 5 '1114X5 R T2 N4X5(R) 12 6 T1 T1 �i 3X4 @ 3X4 3X4 W3 T: =3X4 =2X4(R) 3X4 -vNi M1 W M2 cO W3 ih W2 W1 W1 N LA 1112X4 =3X4 B1 =3X4 1112X4 0-3/4" 0T„ f 8'10" 1'4"--e R=677# U=128# R=677# U=128# H=H1 H=H2 DESC.= G2 SEQ= 960828 PLT.TYP:WAVE yyDESIGN CR pR=FBC2014RESRPI-2007 FTIRT=20%(0/6y O(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.5000 IRUSSESREFESHIPPING,INSTALLING A RM SCSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 .,.�.= ::,::.•,_xf=�,,,.,r.,�.'.'•;:..w..-'S�.q INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. "IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRW G INCLD THE TRUSS IN CONFORMANCE WITH TPP OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OFSHALL NT BE RESONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TOBTRUSSES.DESIGN BC LL O.Opsf CM "a�.,, �f •-�P'-'•,:,;��`� ,�.;.`-�3 CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR �+^^�+-�+•_-+% PLATES ARE MADE OF 20/18116GA(W,WSSlK)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 81000 10-MCA 01 .9Tr 3a•°!1 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY " nal"554i in-,"go INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 .itZG:Y.'W;3ufr TP.F3P'i9,!,�r DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT $JS'ic�ilLtlt9a�3 t �tPT.492�e& DESIGN GNANSRPI1SE2 SHOWN. THE SUITABILITY USOFTHIS COMPONENT FOR ANY BUILDING ISTHE RESPONSIBILITY OFTHE SPACING 24.0' TYPE HIPS Job:(17HS009)/EJ8 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 4.50 fl from roof edge,RISK CAT II,EXP B, Top chord 2x4 SP SS wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bol chord 2x4 SP#1 Dense Wind loads and reactions based on MWFRS with additional C&C member design. t Webs 2x4 SP#3 Left cantilever is exposed to wind Lumber value set"13B"uses design values approved 1/30/2013 by ALSC , s , Deflection meets U360 live and U240 total load.Creep increase factor for dead load is 1.50. Bottom chord checked for 10.00 psf non-concurrent live load. It r MWFRS loads based on trusses located at least 7.50 ft.from roof edge. r 6'6-1/4" R=273# U=97# NAILED 12 T1 6 N pp C 1112X4 3X4(B1) W1 eT 1 1112X4 B1 —1'4" f 8'4" R=605# U=42# RL=137/-30# W=8" R=120# U=14# NAILED (Rigid Surface) DESC.= EJ8 SEQ= 960800 PLT.TVP:WAVE DESIGN CR1T-FSC2014RES/rPI-2007FT/RT-20%(0%y0(0) QTY=23 TOTAL=23 REV. 16.01.01D.0710.12 SCALE=0.5000 F, SHIPPING,INSTALLING AND BRACING. RN TC (BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TRUSSES RE XTRFME CARE IN FABRiCAl ING, TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF 218 NORTH LEE STIR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE �y; /•'y�I/.�" '�:,,,,� LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. BC DL 1 O.O Sf •`x'�` 3 IMPORTANT' FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, p DRWG INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN ; . Ea^• CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES. DESIGN BC LL O,OPSf CM w,,• i r,;,, -•'M=`'�w,,,,, f• - �''.'q CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20/18116GA(W,H/SS/K)ASTM A653 GRADE 40/60(W,KIH,SS)GALV.STEEL.APPLY PLATES TO TOT.LD, 55.Opsf O/A LEN. 80400 x`f;'T',c��S",Y°5`nas"t :°l.4 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI I-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 512 . '6'r-2MP� DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT FL 35114.-4 DESIIGNS OWN.THE SUIT AABI RPI AND SEUSP OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" TYPE EJABUILCK t , Job:(17HS009)/EJ8B THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:138(Effective 6/1/2013) All plates are 2X4 except as noted. Top chord 2x4 SP#1 Dense 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 4.50 ft from roof edge,RISK CAT II,EXP B, Bot chord 2x4 SP#1 Dense wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/_)=0.18 Webs 2x4 SP#3 i Lumber value set"138"uses design values approved 1/30/2013 by ALSC Wind loads and reactions based on MWFRS with additional C&C member design. ��- Left cantilever is exposed to wind y'*51 Bottom chord checked for 10.00 psf non-concurrent live load. e, F Deflection meets L/360 live and L/240 total load.Creep increase factor for dead load is 1 M. �f MWFRS loads based on trusses located al least 7.50 ft.from roof edge. E R=238# U=79# NAILED I - 12 T1 N 6 p N 1113X6 gD 93X6 v B3 ,3X4 W2 =3X4(B1) B2 W1 W2 =3X4 _ Li 01 �-- 1,4„ B �+—1'9-3/4"—�—1'6-1/4" 3/18"3/16' 4, f8-4- R=591# U=41# RL=137/-30# W=8" R=129# U=32# NAILED (Rigid Surface) DESC.= EJ8B SEQ= 960930 PLT.TYP:WAVE SHIPPING,INSTALLINGAND BRACING. �yDyESSIGNN�CRrr=FSC2074RESrrP1-2007 FT/RT=20%(0%)/0(0) QTY=5 TOTAL=5 REV. 16.01.01D.0710.12 SCALE=0.5000 IRUSSFS RFQUIREI-XIHEME:CARE IN"�•• REFER TO$CSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF Va"+'•, 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE �`' LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE � ?.7'-s- '•• INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A TC DL 15.Opsf DATE 01-27-2017 1F p�1,7y PROPERLY ATTACHED RIGID CEILING. "IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRWG 61ji •; '+y INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN %.dre ��`^ - !%� CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES. DESIGN BC LL O.Opsf CM CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20118116GA(W,H/SS/K)ASTM A653 GRADE 40160(W,KIH,SS)GALV.STEEL.APPLY PLATES TO TOT,LD, 55.Opsf O/A LEN. 80400 01 ' �+ 3•E'S EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY win X' s'V7&4m INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 5?YZ M.W:11,5113'2=Afm DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT l`)!iFiAlVt7 BQ:I,tijaff,pL 31rrA DESIGN SHOWN.THE SUITILITY AND AGNS RPI 1 SEC.2.OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THEILDISPACING 24.0" ITYPE EJACK r, 't Job:(17HS009)/J8 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) Special loads ---(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) Top chord 2x4 SP#1 Dense TC-From 94 plf at 0.00 to 94 plf at 8.33 Bot chord 2x6 SP SS BC-From 20 plf at 0.00 to 20 plf at 3.06 Webs 2x4 SP#3:W2 2x4 SP#1 Dense: BC-From 10 plf at 3.06 to 10 plf at 8.33 / Lumber value set"136"uses design values approved 1/30/2013 by ALSC BC-677.18 Ib Conc.Load at 3.06BC-543.50 Ib Conc.Load at 5.06,7.06 Wind loads and reactions based on MWFRS. 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT II,EXP B,wind TC Left cantilever is exposed to wind DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 (J)Hanger Support Required,by others Right end vertical not exposed to wind pressure. Deflection meets U360 live and L/240 total load.Creep increase factor for dead load Is 1.50. Bottom chord checked for 10.00 psf non-concurrent live load. Provide hanger or special connection at right end of truss for 1194 lbs. 1112X4 12 T1 6 F::—,- W3 zo "v 3X4 W2 =3X4(A1) VV1 T 1113X4 B1 III3X5(R) F 8'4" R=1476# U=278# W=8" R=1194# U=219# (Rigid Surface) H=H1 DESC.= J8 SEQ= 960835 PLT.TYP:WAVE yD�ESSIIGNN�CRIT=FBC2014RES7rPI-2D07 FT/RT=20%(0°6)1CIO) QTY=2 TOTAL=2 REV. 16.01.01D.07.10.12 SCALE=0.5000 REFER TO$CSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.0psf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE •�'"'7`•ti, !�"' '`>. LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE Y�'1 V "'•��,,,,..�..'�i, `t INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A TC DL 15.Opsf DATE 01-27-2017 PROPERLY ATTACHED RIGID CEILING. .S ase "IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRWG INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN "'4,.•- ` •. _ CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES. DESIGN BC LL O.Opsf CM CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR ^7 •-` PLATES ARE MADE OF 20118/16GA(W,H/SSM)ASTM A653 GRADE 40/60(W,WH,SS)GALV.STEEL.APPLY PLATES TO TOT.LD, 55.Opsf O/A LEN. 80400 IINSTA 49'04)r:3IL0&l EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY ,sre;kz'2.°°�i.ti`s 1717N -A' INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 5 Wd3:£1''4. 15TZ211 DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT Er38�Pz+ut1J �, rwd'R£.°3165 BUILDIINSHOWNNERESUIIPERAABILITY AND I/TPI SEUS2OFTHISCOMPONENTFORANYBUILDINGISTHERESPONSIBILITYOFTHE SPACING 24.0" TYPE MONO ii Job:(17HS009)/J5 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 it mean hgt,ASCE 7-10,CLOSED bldg,not located within 4.50 ft from roof edge,RISK CAT II,EXP B, wind TC DL=6A psf,wind BC DL--5.0 psf.GCpi(+/-)=0.18 Top chord 2x4 SP#2 N Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additionat C&C member design, r•- Webs 2x6 SP SS:W2 2x4 SP#3: :Lt Levet Return 2x4 SP#3: Bottom chord checked for 10.00 psf non-concurrent live load. Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Deflection meets U360 live and 0240 total load.Creep increase factor for dead load is 1.50. Left end vertical exposed to wind pressure.Deflection meets 1-1360. MWFRS loads based on trusses located at least 7.50 ft.from roof edge. 7 ---4'5-3/4„ _I R=192# U=64# NAILED 6 � T1 �3X6 0 v =3X4(R T =3X4 6- M1 v W1 W2 NI 1 S 1112X4 B1 2X4 1'4-3/4" 4'11-1/4" 'I R=423# U=19# RL=144/-89# W=7-1/4" R=103# U=51# NAILED (Rigid Surface) DESC.= J5 SEQ= 961819 PLT.TYP.-WAVE DESIGN CRIT-F802014RESRPL2007FTMT=20%(0%vNO) QTY=2 TOTAL=2 REV. 16A1.01D.0710.12 SCALE=0.5000 ..yyp�(N .. . r,:i.wrri REFER 1) $CSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TO LL 30,Opsf REF ;,«:•"� .1 . '^s 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA,22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN.MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS.UNLESS OTHERWISE TO DL 15.Opsf DATE 01-27-2017 INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. BC D(„ I O.Opsf DRWG '"IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES.DESIGN BC LL O.Opsf CM CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI,ALPINE CONNECTOR PLATES ARE MADE OF 20/18116GA(W,WSSIK)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O!A LEN. 47104 'ANSIC.4(RMI 15975-3308'� EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 150A-Z.ANY PPRP.:w0a4,I?74 W90 INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 5111+,3£"S-V`i`X1111(TannAf"'z DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT JACK iAt33txF?AILy5,'_d"� E 31thi�l DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE S PACING 24.0" TYPE BUILDING DESIGNER PER ANSI/TPI 1 SEC.2. Job:(17HS009)/J2 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT II,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. Webs 2x6 SP SS :Lt Level Return 2x4 SP#3: Bottom chord checked for 10.00 psf non-concurrent live load. Lumber value set"1313"uses design values approved 1/30/2013 by ALSC Deflection meets U360 live and L/240 total load.Creep Increase factor for dead load is 1.50. y/ Left end vertical exposed to wind pressure.Deflection meets L/360. R=70# U=69# NAILED 12 6 � T1 1112X4 "3X4 �o?mT =3X4 CN W1 N 1114X5 B1 �—1'4-3/4" h 27 R=288# U=33# RL=98/-79#W=7-1/4" (Rigid Surface) R=39# Rw=40# U=22# NAILED DESC.= J2 SEQ= 961822 PLT.TYP:WAVE ��1yDyESSIGNN��CRI{T-FBC2014RESrrP1.2007FT/RT=20°%(0%Y0(0) QTY=2 TOTAL=2 REV. 16.01.01D.0710.12 SCALE=0.7500 ,,;,=^`-::,.•„� SHIPPING,INSTALLING AND BRACING. REFERI70BCSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 '' '°:•' �'+% ,._. :,x; INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. "IMPORTANT`• FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.0psf DRWG INC` -T- � �`•'• '!-`r te•' RUSS IN CON ORMAN SHALL CT BE ONSIBLE E WITH TPI;OR FABRICATING HANDLING,SHIPPINGON FROM ,INSTALLING&BRACING OF RS DESIGN;ANY FAILURE TO IUSSES.LD THE TDESIGN BC LL O.Opsf CM �'-""�•,.,,,,�( ;,,,..•"F-°^•."„µr -.;.+ CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC.BY AF&PA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20118/16GA^H/SS/K)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 20200 '00AEACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN.POSITION PER DRAWINGS 160A-Z.ANY V.1.'li-",+ .5 gwWAgg'a INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#: 17HS009 32l'U'Tl,Vd,154913��..F3,FS;t4f�..�5 DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT a^y3k�L V.)7j&%C'ff+FL 33&% DESIGNS OWN.THE SUITABILITY I AND UC.SE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THEU'L SPACING 24.0" TYPE JACK ` n a Job:(17HS009)/J1 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT II,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MW FRS with additional C&C member design. Webs 2x6 SP SS :Lt Level Return 2x4 SP#3: Bottom chord checked for 10.00 psf non-concurrent live load. Lumber value set"139"uses design values approved 1/30/2013 by ALSC Deflection meets L/360 live and L/240 total load.Creep increase factor for dead load is 1.50. Left end vertical not exposed to wind pressure. 7-1/4" R=-10# Rw=13# U=51# NAILED 12 6 T1 1112X4 83X4 =3X4 m io v o M1 ,a (V (V W1 N Li 1112X4 0 �--1'0-3/4" 1'4-3/4" R=265# U=6# RL=40/-30#W=3-1/4" (Rigid Surface) R=14/-9# Rw=16# U=18# NAILED DESC.= J1 SEQ= 961776 PLT.TYP.WAVE ryry(DESIGN CRIT=FBC2014RESfrPI.2C07FT1RT=20%(0% 0(0) QTY=2 TOTAL=2 REV. 16.01.01D.0710.12 SCALE=1.0000 -v: REFERN� HANDLING,SHIPPING,INSTALLING AND 0 SCSI(BUILDING COMPONENT SAFETY INFORMATION),PUBCATINGLISHED BY TPI(TRUSS PLATE INSTITUTE,EME CARE IN FABRI TC LL 30.Opsf REF 218 NORTH LEE STIR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LNND, ICATED,ADISONT I PCHORD PRACTICES PERFORMING THESE FUNCTIONS. SHALL HA E P OPERLY ATTACHEDTRUCTURALPANELS ANDBOTT M CHORD SHALLJT HAVE A C DL 1DATE 01-27-2017 .5.Opsf PROPERLY ATTACHED RIGID CEILING. BC DL 1 OO Sf DRW G "iP.�++� ,L�fh:-✓!.ems "IMPORTANT" . FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, P INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN � �` T� +Y• + '' CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES. DESIGN BC LL O.Opsf CM t"'•=.- t r=':,' CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20/18/16GA(W,H/SS/K)ASTM A653 GRADE 40/60(W,KIH,S5)GALV.STEEL.APPLY PLATES TO TOT.LD, 55.Opsf O/A LEN. 10012 {M1.c e91ov,51JS 3$':: EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY 3`AX%'r 0Z1541 lYf INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 n224>:i,"v'I.:16A7L7MPAJ= DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIGN SHOWN.THE SUITABILITY ANSI/TPI RPI 1 D 2USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE BUILDING SPACING 24.0" TYPE EJACK Job:(17HS009)/J4 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 4.50 ft from roof edge,RISK CAT ll,EXP B, Top chord 2x4 SP#2 N wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. Webs 2x6 SP SS :Lt Level Return 2x4 SP#3: Bottom chord checked for 10.00 psf non-concurrent live load. Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Deflection meets L/360 live and L/240 total toad.Creep increase factor for dead load is 1.50. Left end vertical exposed to wind pressure.Deflection meets L/360. 4'0-5/8" —� R=183# U=85# NAILED 12 5.42 p T1 1112X4 ED io =2X4(R T =3X4 6- M1 Ln V W1 fV 1 1117X6 81 {�1'6-7/16"- f+ 4'6-1/8" R=414# U=33# RL=129/-83# W=7-1/4" R=87# U=18# ,NAILED (Rigid Surface) DESC.= J4 SEQ= 961825 PLT.TYP:WAVE DESIGN CRR-MC2014REMP1-2007 FT/RT"20%0(0%)/0(0) QTY=2 TOTAL=2 REV. 16.01.01D.0710.12 SCALE=0.5000 g�yypp .. REFERNI)O�CSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE TC DL 15.0p sf DATE 01-27-2017 INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. 1 O0 Sf "IMPORTANT' BC DL . FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, p DRW G ���••t3F{ INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN ut ,Yi.p.12.?,f •dt �fiJ6.3'Lt'-SJt• CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES. DESIGN BC LL O.Opsf CM CONFO PLATES RMS RE MITH ADE OF 20/18/16GA(W,FVSS/K)ASTM (NATIONALLE PROVISIONS OF NDS653 GRADE 01 0(W,K/H,SS)GALVBY ASTEELAND?APPY PLATES TOPI.ALPINE CTOR TOT.LD. 55.Opsf O/A LEN. 40602 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY a'=!z izo vu-S`S6 INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DIJR.FAC. 1.25 JOB#: 17HS009 3:2G i.'Gi,?164'.b 3.28E Af.,R, DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIGN SHOWN.THE SUITANSI/TPIABILITY 1 D 2USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" TYPE JACK Job:(17HS009)/J3 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 It mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT II,EXP B,wind TC DL=5.0 psf,wind SG DL=5.0 psf.GCpi(+/-)=0.18 Top chord 2x4 SP#2 N Bot chord 2x4 SP#2 N Wind)Dads and reactions based on MW FRS with additional CBG member design. Webs 2x6 SP SS It Level Return 2x4 SP#3: Bottom chard checked for 10.00 psf non-concurrent live load. ? � Lumber value set"ll 36"uses design values approved 1/30/2013 by ALSG Deflection meets U360 live and U240 total load.Creep increase factor for dead load is 1.50. Left end vertical exposed to wind pressure.Deflection meets U360. h• --- 3'4-7/8" --- R=153# U=78# NAILED 12 T1 5.42 1112X4 a r; :a =2X4(R O1 io M1 4 t N W1 N 1116X6 81 �--16-7/16" 310-3/6" —I R=381# U=35# RL=1191-61#W=7-1/4" R=74# U=18# NAILED (Rigid Surface) SEQ= 961828 DESC.= J3 REV. 16.01.01D.0710.12 SCALE=0.7500 PLT.TYP:WAVE DESiGNCRIT"FBC201CRESRPb200)FT1RT-20%10%yn(u) QTY=2 TOTAL=2 RRN�O$CSi Sit INSTITUTE, COMPONENT SAFETY INFORMATION},PUBLISHED BY HANDLING, {TRUSS PLATE INSTITUTE, TC LL 30Apsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS.UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 3%''t, 4 Vit. -%' u.�ja. INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A gG DL 1�•OPSf DRW G PROPERLY ATTACHED RIGID CEILING. *•IMPORTANrr FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, ++,��� yy'� ;.pi"+�xa - y; INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN BC LL 0.0psf CM _ .#� 9,1cn1. CONFORMANCE WITH TPI:OR FABRICATING.HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES.DESIGN -ra.,,,,-4" "'"• CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20118/160A(W,WSSIK)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 31ao6 160A yi'}??7 33°�J EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY 1.25 JOB#:17HS009 lxx;Q:�+107V.99 0 INSPECTION OF PLATES FOLLOWED BY(I)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DURYAC. " 321.13 nf,W.IEA DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT N 01X a'P,:AN 0 24 v��CU,FL33" DESIGN SHONG WN. THE ER,UITABIANSY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0° TYPE JACK BUIL '. f Job:(17HS009)/BJ6 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) Special loads -----(Lumber Dur.Fac.=1.25/Plate Dur.Fac=1.25) Top chord 2x4 SP#2 N TC-.From 0 plf at-1.64 to 93 plf at 0.00 Bot chord 2x4 SP#2 N TC-From 2 plf at 0.00 to 2 plf at 5.60 a° Webs 2x6 SP SS BC-From 2 plf at 0.00 to 2 plf at 5.60 :Lt Level Return 2x4 SP#3: TC-70.10 lb Conc.Load at 2.52 TC-182.81 Ib Conc.Load at 4.67 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC BC-38.98 Ib Conc.Load at 2.52 1b - Bottom chord checked for 10.00 psf non-concurrent live load. BC-86.72 Ib Conc.Load at 4.67 Deflection meets U360 live and L/240 total load.Creep increase factor for dead load is 1.50. 5'1-3/4" R=180# NAILED 12 5.22 p T1 1112X4SO m o� v =2X4(R TT =3X4 M1 (V W1 1 1 1112X4 81 57-1/4" �1 R=261# W=7-7/8" R=109# NAILED (Rigid Surface) DESC.= BJ6 SEQ= 961845 PLT.TYP.WAVE ryryDyyESSIGN CRIIT-Fec2014RESNPI-2007 FT1RT-20%(0%y0101 QTY=2 TOTAL=2 REV. 16.01.01D.0710.12 SCALE=0.5000 REFERNBSHIPPING,INSTALLING ANU BRACING. CSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, 218 NORTH LEE STIR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE TC LL 30.Opsf REF •"���'t, 1 " ''*n•;- LN,MADISON,WI 53719 FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE 4 TC DL 15.Opsf DATE 01-27-2017 INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A yo.4Jt,.sr••r�..��::.. 'meq 14�t PROPERLY ATTACHED RIGID CEILING. '*IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRW G INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES. DESIGN BC LL 0.0psf CM °` d ,��`k'"+«,;,;- * :•*' CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20118116GA(W,WSSIK)ASTM A653 GRADE 40160(W,K/H,SS)GALV.STEEL.APPLY PLATES TO `4WA VIVA)T.'✓-u'av''�. EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY TOT.LD. 55.Opsf O/A LEN. 50704 PA_':'1:R-1, INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 BUILDING ax?z Z4.1F:.166 TMIP,`�rlm DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIGSHOWN.THE SUITABILITY ABILITY AND SEC. OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0't ITYPE HIP JACK Job:(17HS009)/BJ4 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/112013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT 11,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 n Bot chard 2x4 SP#2 N Wind loads and reactions based on MW FRS with additional C&C member design. Webs 2x6 SP SS 4 :Lt Level Return 2x4 SP#3: Bottom chord checked for 10.00 psf non-concurrent live load. s Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Deflection meets L/360 live and L/240 total load.Creep increase factor for dead load is 1.50. Left end vertical exposed to wind pressure.Deflection meets L/360. 3'0-9/16" R=133# U=73# NAILED 12 5.22 p T1 12 1112X4 r iD in �2X4(R c ch M1 (V W1 N 1 1115X6 B1 3'6-1/16" R=371# U=41# RL=1121-77# W=7-7/8" R=66# U=18# NAILED (Rigid Surface) DESC.= BJ4 SEQ= 961848 PLT.TYP:WAVE DESIGN CRIT=FBC2014RESNPI-2007F7/RT=20%(0%)10(0) QTY=2 TOTAL=2 REV. 16.01.01D.0710.12 SCALE=0.7500 yyyypp pu REFERN�O SCSI(TRUSSES REQUIRE EXTREME URE IN I-ABRiL;AIINU. COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE • ''''+7':}. µ/..�" „ LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A TC DL 15.Opsf DATE 01-27-2017 PROPERLY ATTACHED RIGID CEILING. BCDL 1 0.0 Sf DRW G '*IMPORTANT** FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS,INCp -I: x�+E%��" ` B• 1� CONFORMANSHALL CE WITT BE H RESPONSIBLE FABRICR ANY DEVIATION ATING,NG,HANDLING,SHIPPING,NG,INSTALLING&BM THIS DESIGN;ANY RILURE ACING NGTO BUILD RUSSES.DESIGN BC LL O.Opsf CM L'•_*.,.,, I ";-••""T`"^4I,r`_`'` "r�° CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20118/16GA(W,WSS/K)ASTM A653 GRADE 40160(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 30601 `.a:'(i{S.ci%.;'r••'L•3. EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY :: 44;,184,t3D INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.ASEAL ONTHIS DUR.FAC. 1.25 JOB#:17HS009 $12X5 UT.w lSilr TZMP iS,HT DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIGN NSHOWN. NERTHE SUII SUITABILITY II AND US2 OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0 TYPE HIP JACK Job:(17HS009)/CJ6 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 It mean hgt,ASCE 7-10,CLOSED bldg,not located within 4.50 ft from roof edge,RISK CAT Il,EXP B, Top chord 2x4 SP#2 N wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. ' Webs 2x4 SP#3 Left cantilever is exposed to wind j Lumber value set"1313"uses design values approved 1/30/2013 by ALSC Deflection meets U360 live and U240 total load.Creep increase factor for dead load is 1.50. Bottom chord checked for 10.00 psf non-concurrent live load. Ih�' 4'6-1/4" R=186# U=70# NAILED 12 T1 6 p IV � 'R 1112X4 =3X4(81 W1 4 61 �—1'4" f a 6'4" R=504# U=31# RL=104/-23# W=8" R=76# U=12# NAILED (Rigid Surface) DESC.= CJ6 SEQ= 960797 PLT.TYP:WAVE ryDyEpSIGNN�CRoR=FBC201ARESfPI.2007FTRT=20%(0°/au0(0) QTY=7 TOTAL=7 REV. 16.01.01D.0710.12 SCALE=0.7500 _ *H• REFER 7SHIPPING,INSTALLING AND bRAGINIJ. 0 B•C51(BUILDING COMPONENT SAFETY INFORMATION),PUB-5 REQUIRE EKIRhME CARE IN LISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LNND, ICATED,TOPICHORD SHALL HAVE P OPER Y ATTACH DPERFORMING RAL PANELS AND BOTTOM CHORD SHHALLf HAVE A TC DL 15.0 Sf DATE 01-27-2017 ryt,yp�,y yy,7 PROPERLY ATTACHED RIGID CEILING. . ' BC DL 1 0.0 Sf '+ t'r 'IMPORTANT' FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, P DRW G INCIN CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,HI P NGSHALL NT BE RESPONSIBLE FOR ANY DEVIATION FROM THI,INSTALLING& ILURE BDESIGN;ANYRACING NG OF TRIUSSES.THELD TRUSS DESIGN BC LL O.Opsf CM CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA AND TPI.ALPINE CONNECTOR �— •^"'*"" ' '•b �"' PLATES ARE MADE OF 20/18116GA(W,HISSIK)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 60400 `MAi�`:b3'F:17S 3 °^ EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY ' aF'A*IKZ 00.0 1174-14999 INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DU R.FAC. 1.25 JOB#:17HS009 5172 N.W.lryfi 3'F.FIRkA= DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT lm '.mwo 73.r`�.ca' DESIGN SHOWN.DETHE SUITABILITY S RPI 1 D USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" TYPE JACK Job:(17HS009)/CJ6A THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 4.50 ft from roof edge,RISK CAT II,EXP B, Top chord 2x4 SP#2 N wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MW FRS with additional C&C member design. Webs 2x6 SP SS Bottom chord checked for 10.00 psf non-concurrent live load. Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Deflection meets U360 live and L/240 total load.Creep increase factor for dead load is 1.50. cJ r r 4'6-1/2" R=234# U=35# RL=82# NAILED 12 T1 6 N � C7 V ih gTII 1112X4 I N W1 LL� 1113X5 g1 5' R=284# U=68# W=8" R=100# NAILED (Rigid Surface) DESC.= CJ6A SEQ= 960916 PLT.TYP:WAVE INSTALLING AND BRACING. ryryDyyESSIGNN��CRrr-FeC2014RESrn`I.2007FTIRT=20%(0%)10(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.7500 MR70$CSI(BUILDINGCOMPONENT SAFETY INFORMATION),PUBRUSSIE RhUUIKE EXTREME CARE IN LISHEDBYTPI(TRUSS�PLATE INSTITUTE, TC LL 30.Opsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE J 4•''r LN,MADISON,W 153719 FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS.UNLESS OTHERWISE ..,' ,�' � � ,�� ) TC DL 15.Opsf DATE 01-27-2017 INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. r ' �* 'IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRWG y. �• +•• INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN -r<. �• ���• �*`t' •�!- ' CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING 8 BRACING OF TRUSSES. DESIGN BC LL O.Opsf CM C- _f `;;.,•"'F"M.;,;�` S oma" CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20118/16GA(W,WSS/K)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 5 (R `aW'ZA 199,3.1T:5L-S$°;` EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-2.ANY mn 551)"773-1.980 INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1.2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 312G;K.S7'7-:t:riI:t'M3.F Styr DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT 1"Olv,LPxbd'•70IM?ACIE4 DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 240" JACK BUILDING DESIGNER PER ANSI/TPI 1 SEC.2. . TYPE (� u Job:(17HS009)/CJ66_ THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFRS LAYOUT Value Set:13B(Effective 6/1/2013) All plates are 2X4 except as noted. Top chord 2x4 SP#2 N 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 4.50 ft from roof edge,RISK CAT 11,EXP B, Bot chord 2X4 SP#2 N wind TC DL=6.0 psf,wind BC DL=5.0 psf,GCpi(+/-)=O.18 r R; Webs 2x4 SP#3 Wind loads and reactions based on MW FRS With additional C&C member design. Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Left cantilever is exposed to Wind Bottom chord checked for 10.00 psf non-concurrent live load. Deflection meets U360 live and U240 total load.Creep increase factor for dead load is 1.50. R—*190# U=69# NAILED W 12 6 p Ex I I W2 (8)3 co 3X4 fVH W2 =-3X4(81 W1 iD T F-1 I V4. � 1'9-3/4" 1-6-1/4- 1311 8-3/16"+' V4' R=488# U=30# RL--104/-23#W=8" R=66# U=14# NAILED (Rigid Surface) DESC.= GJ6B SEQ= 960933 PLT,TYP.-WAVE DESIGN CFttT=FSC2014RES1TPI4007 FTIRT­20%0%Y0(0) QTY=2 TOTAL=2 REV. 16.01.01D.0710.12 SCALE=0.7500 "MMrIN —TRUSSES REQUIRE EXTREME CARE IN FABRICATING,HANDLING,SHIPPING,INSTALLING AND BRACING. St(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, R 11 TC LL 30.Opsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA_22314)AND CA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE To PERFORMING THESE 15.Opsf DATE 01-27-2017 if> LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR E FUNCTIONS.UNLESS OTHERWISE TC CIL INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. BC CIL 1 O.Opsf DRWG '!IMPORTANT' FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, m. INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES.DESIGN BC LL O.Opsf Cm .;.qQjp Fr,-.,- -T­;�'r-; CONFORMS WITH APPLICABLE PROVISIONS OF NOS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR 55.Opsf O/A LEN. 60400 PLATES ARE MADE OF 20118116GA(W,FVSS/K)ASTM A653 GRADE 40/60(W,VJH.SS)GALV.STEEL.APPLY PLATES TO TOTID. `i%$TA i9tv.)MLM-01 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY P.AZ:054)127P_z9P'D INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TR 1-2002 SEC.3.A SEAL ON THIS DURYAC. 1.25 JOB#:17HS009 .14.V-4.11,4b Trig,. DRAWINGDRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" TYPE JACK BUILDING DESIGNERPER ANSIfrPI 1 SEC.2. Job:(17HS009)/CJ4 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere In roof,RISK CAT 11,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. Webs 2x4 SP#3 Left cantilever is exposed to wind Lumber value set"'I 3B"uses design values approved 1/30/2013 by ALSC Bottom chord checked for 10.00 psf non-concurrent live load. A Deflection meets U360 live and U240 total load.Creep Increase factor for dead load is 1.50. 2'6-1/4" R=94# U=43# NAILED 12 T1 6 1112X4 90 N v (V =3X4(B1 W1 1112 4 1'4' B1 R=423# U=19# RL=71# W=8" R=25/-10# Rw=25# U=12# NAILED (Rigid Surface) DESC.= CJ4 SEQ= 960794 PLT.TYP:WAVE DESIGN CRR-FBC2014RESRPI-2007FTIRT"20%(0%y0(0) QTY=7 TOTAL=7 REV. 16.01.01D.0710.12 SCALE=1.0000 'N51R NQ" SHIPPING,INSTALLING AND BRACING. REFER 70 SCSI(TRUSSES REQUIRE= UAFINU. COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF ie. 218 NORTH LEE STIR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE S`"���•�. ;' LN,MADISON,WI 53719 FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 _ - 'f INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A `� +��� •�,'..,. ..,.. x' PROPERLY ATTACHED RIGID CEILING. "IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRW G W31, INCRUSS IN CON OHRMANCE WITH TPPSHIPPING,NOT BE RESONSIBLE FOR ANY DEVIATION O OR FABRICATING,HANDLING, INSTALLING&BM THIS DESIGN:ANY RACING NG OF RILURE TO IUSSES.LD THE TDESIGN BC LL O.Opsf CM '�^^w�„_I_;;,,;.•''"•'+•..,,,�, „•=' CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR 'r+*-^-� +n �-1• PLATES ARE MADE OF 20118116GA(W,WSSIK)ASTM A653 GRADE 40160(W,KIH,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 40400 'i°IMt Fc ON441')n✓r'r3£: EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY a?•'1,X 2`;%' Q 1/744;95:1 INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DU R.FAC. 1.25 JOB#:17HS009 512.1;M.W.u'6 TM3&St11:3T DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT k";3$�?P.c'�t'•ti{y?:�>J�,n„3,gT4.,y DESIGN GN SHOWN.THE PERSUITABILITY I SEUSC.2E OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THEBUILDISPACING 24.0" TYPE JACK f. ' Job:(17HS009)/CJ4A THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere In roof,RISK CAT II,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. Webs 2x6 SP SS ,.. , Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Bottom chord checked for 10.00 psf non-concurrent live load. r ,� Deflection meets L/360 live and L/240 total load.Creep increase factor for dead load is 1.50. , 2'6-1/2" R=140# U=21# RL=49# NAILED 12 6 p T1 1112X IV E4 N N W1 FM 13 B1 3' R=170# U=39# W=8" R=60# NAILED (Rigid Surface) DESC.= CJ4A SEQ= 960919 PLT.TYP:WAVE yyDESIGN CRIT-FBC2014RES/rP62007FT/RT"20%(0%y0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=1.0000 TRUSSES REQUIRE L:XlRhME:CARE IN FABRICATING,' ,REFEFfN�O bSHIPPING,INSTALLING AND BRACING. 'SI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF "'"�,,i'M."'�•. 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA 22314)ANDWTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 .g=_,:,,.,;,./..,,,.,,,.z...�•..__,�,��.'.LC.,,,,_;.,c; INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A • ;F PROPERLY ATTACHED RIGID CEILING. BC DL 1 O.O Sf "IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, P DRW G ,• T,1 11.4, �p^�y;�j INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN O.OpSf CM �:,.�, Y,.-� .G 9Y•d.S3V CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING 8 BRACING OF TRUSSES. DESIGN BC LL p`K..., k'+•.,,.,wry .,-' CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR �•+<' PLATES ARE MADE OF 20118116GA(W,HISS/K)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 3 'Llk?TA QR&O EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY -ow-'vino INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS aA2G DUR.FAC. 1.25 JOB#:17HS009 q.Ve,.16111�'Fd13SSAf_'R.' DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT x wUa,t N0 Rp?A CEFt Fr,3xrhA DESIGNS OWN.THE SUITABILITY ANSI/TPIA SECS2 OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THEBUILDISPACING 24.0" ITYPE JACK �� r Job:(17HS009)/CJ4B THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT ll,EXP B.wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind toads and reactions based on MWFRS with additional C&C member design. Webs 2x4 SP#3 Left cantilever is exposed to wind Lumber value set"13B"uses design values approved 1/30/2013 by ALSC 3 { Bottom chord checked for 10.00 psf non-concurrent live load, ,;Y' r Deflection meets U360 liv@ and V240 total load.Creep increase factor for dead load is 1.50. r 4'4" ,. R=107/-4# U=57# NAILED 1112X4 12 T1 6 .0 1112X4 iv W2 N � N N (V 3X4(B1 W1 io 1112 4 1112X4 1'4" 3'4" 1' 81 R=400# U=18# RL=71# W=8" (Rigid Surface) DESC.= CJ413 SEQ= 960946 PLT.TYP-WAVE ry�DESIGN ��CRIIT-FBC2014RES/TPI.2007FT/RT"20k(0Yov0(0) QTY=2 TOTAL=2 REV. 16.01.01D.0710.12 SCALE=1.0000 REFER7SH115151ITT,78TALLING AN RACING. 0 SCSI(BUILDING COMPONENT SAFETY INFORMATION),PUBTRUSSES REQUIRE EXTREME CARE IN LISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. �g "IMPORTANT' FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRWG INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN £: CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES. DESIGN BC LL O.Opsf CM CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR 3s°3"sIa>i PLATES ARE MADE OF 20118/16GA(W,WSS/K)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 40400 xkic �?^ EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY ')97T—939 INSPECTION OF PLATES FOLLOWED BY(I)SHALL BEPER ANNEX A3OFTPI 1-2002 SEC.3.ASEAL ONTHIS DUR.FAC. 1.25 JOB#:17HS009 3122 1.1(.W..166 TEMIRArM DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIGN SHOWN. WN.THE SUI ANS RYANDUS2 OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE BUILDINGDESIGNER, SPACING 24.0" TYPE JACK Job:(17HS009)/CJ2 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bidg,Located anywhere in roof,RISK CAT Il,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MW FRS with additional C&C member design. Webs 2x4 SP#3 Lumber value set"1313"uses design values approved 1/30/2013 by ALSC Left cantilever is exposed to wind � p, Bottom chord checked for 10.00 psf non-concurrent live load. ' 1; Deflection meets L/360 live and L1240 total load.Creep increase factor for dead load is 1.50. {f 6-1/4"+{ R=-175# Rw=14# U=116# NAILED 12 1112X4 6 T1 N 3X4(B1 W1 `* T FM in 113 B1 �—1'4" { —9.4— R=593# U=54# RL=38# W=8" (Rigid Surface) R=-169# Rw=22# U=134# NAILED DESC.= CJ2 SEQ= 960791 PLT.TYP:WAVE DESIGN CRIT=F8C2074RES/TPI-2007FT/RT=20%(0%)/0(0) QTY=18 TOTAL=18 REV. 16.01.01D.0710.12 SCALE=1.0000 n R NSu TRUSSES REQUIRE EXTREME C/ SHIPPING,INSTALLIRMAT10=0. REFER 70 CSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF i� 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,5300 ENTERPRISE P Y.r-^'t�'r3`•x (✓.rz'Yy;, LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 ry,^;;,,,;;,,,,;,„,,,,.._,.;,•��.,,,.,.,,,,:,,�,.,,,�,,. �, INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. "IMPORTANT” FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR,ALPINE ENGINEERED PRODUCTS, BC DL 10.0psf DRW G ,'.'S } R�;A ^57(4Y+r'y•i`,*at, INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES. DESIGN BC LL O.Opsf CM r."�~ „•�' CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR �1^^^-^�'--°"- M •�' �'"E' > PLATES ARE MADE OF 20118/16GA(W,H/SS/K)ASTM A653 GRADE 40/60(W,KIH,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 20400 M.,;V ti1r r1:._ZM EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY FAX:054'1 4?ilt-'s` ' INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 $12l3 M,w I&A,TFMPi 47:;': DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT oo.gaav%l{ lke: um'n 13rKyy DESIGN NSHOWN. THE SUIER,PER TABILITY AND USE OFTHIS COMPONENT FOR ANY BUILDING 15THE RESPONSIBILITY OFTHEBUILDISPACING 24.0" TYPE JACK N n Job:(17HS009)/CJ1A THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:,13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT II,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/.)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MW FRS with additional C&C member design. Webs 2x6 SP SS :Lt Level Return 2x4 SP#3: Bottom chord checked for 10.00 psf non-concurrent live load. :d' C1 ✓ Lumber value set"138"uses design values approved 1/30/2013 by ALSC Deflection meets L/360 live and L/240 total load.Creep increase factor for dead load is 1.50. y) Shim all supports to solid bearing. 4 ii -3/4'� R=57# RL=43# NAILED R=36# U=12# NAILED 12 R— # U=39# W=7- 4" 6 (R I� Urface) 1112X4 3X4 __ io io M1 N N O_ (7 W1 to 6 fV cV ' FM 1113X5 81 1'4-3/4" r2-4- R=189 NAILED DESC.= CAA SEQ= 960822 PLT.TYP:WAVE ryryDyyESSIGNN��CRIT-FBC2014RESRPI-2007 FT/RT=20%(0%)/0(0) QTY=4 TOTAL=4 REV. 16.01.01D.0710.12 SCALE=0.7500 TRUSSES REQU RE EX I ,�:^'�.w.•w I BRACING. REFERTO SCSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY RhME CARE IN FAURICATING, TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF Y rot to„�Y 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE „,;r. 3• ti. i(/ ,;�, LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE . !;,.-.., .,,,._„_~�rs., ,,, ,,� INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A TC DL 15.Opsf DATE 01-27-2017 --T�. -�• PROPERLY ATTACHED RIGID CEILING. "�� 'IMPORTANT” FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRWG ? 5-6`• '�•`^ INCJ ULD THE TRUSS IN CONFORMANCE WITH TPSHALL NT BE LOOR FABRICATING,HANIDLIING,HIIPP NGI,INSTALLING&BARAC NGNSIBLE FOR ANY DEVATON FROM THS DESIGN;ANY FILURETOFBTRIUSSES.DESIGN BC LL O.Opsf CM ''•Y:w,,, 6 ,;;,,•^`f"`�•:,;qr CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20118/16GA(W,WSS/K)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT,LD. 55.Opsf O/A LEN. 1104 gvjS 4"YO4)4?,-an% EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY r.'-'x21V.r:r)tii8-emm INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DU R.FAC. 1.25 JOB#:17HS009 Z;71Yj Tiap�r DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT a''fn"R6A-T")n.. Vc-tT HL xj&% BUILDING OWN.THE SUITABILITY ANS RPIA SECS2 OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0' TYPE JACK Job:(17HS009)/HJ8 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT 11,EXP B,wind TC Top chord 2x4 SP#1 Dense DL=5.0 psf,wind BC DL=5.0 psf.GCp1(+/-)=0.18 Bol chord 2x4 SP#1 Dense Wind loads and reactions based on MWFRS. Webs 2x4 SP#3 Lumber value set"138"uses design values approved 1/30/2013 by ALSC Left cantilever is exposed to wind The following members need concentrated loads at the heel:3-0-0 span/setback member on the 1-3-8 cant side requires 16 Sub-fascia beam assumptions:3-0-0 sub-fascia beam on the 1-3-8 cantilever side.3-0-0 sub-fascia beam on the 1-3-6 lbs and the 3-0-0 span/setback member on the 1-3-8 cant side requires 16 lbs. cantilever side. t3 Hlpjack supports 8-3-B setback jacks with 1-3-8 cantilever one face;1-3-8 cantilever opposite face. r Deflection meets U360 live and U240 total load.Creep increase factor for dead load is 1.50. 'oe 9'3-3/8" R=431# U=130# NAILED 12 T1 4.24 p 03X4 `v M r; -v 1112X4 W3 3X4(B1 W T I FE s• =3X4 B1 2X4 1'9-718" F 11'8-11/16" R=671# U=110# W=11-5/16" R=410# U=15# NAILED (Rigid Surface) DESC.= HJ8 SEQ= 960803 PLT.TYP:WAVE HANDLI SHIPPING,INSTALLING AND BRACING. yyDyyESSIGNN��CRrr=FBC20I4RESlrPI-2007FTIRT-20%(0%v0(0) QTY=4 TOTAL=4 REV. 16.01.01D.0710.12 SCALE=0.5000 REFERTO SCSI(BUILDING COMPONENT SAFETY INFORMATION),PUBTRUSSES REQU]RhhXIREMF CARE IN LISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF �_ 'A' y;� 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA 22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE y.:•` �J ,f it 4 y, LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISEDATE 01-27-2017 INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A TC DL 15.Opsf PROPERLY ATTACHED RIGID CEILING. �`�'•"� '^�'+� "IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRWG �����•� 6 H. INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN '�f7.°"�• �'t� "i'• "6 CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING 8 BRACING OF TRUSSES.DESIGN BC LL O.Opsf CM '�+�.., I f,„.-°"I`�•�.;,µ .�",,.�;j CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20118/16GA(W,FUSS/K)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 110811 `£'Ci .c 'Ya}'�S u'E4•l EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY + PAX,M.)17iit-Cm INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 377X1:�3.W,11,91 TA'Fi33Ar DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT k'138Ip,1,1g0 D?3r.`U,M 33,WS DESIIGN SHOWN.THE SUI ANS RPI 1 SEC2. SPACING OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" TYPE HIP JACK Job:(17HS009)/HJ8B THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) All plates are 2X4 except as noted. Top chord 2x4 SP#1 Dense 170 mph wind,15.00 it mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT 11,EXP B,wind TC Bot chord 2x4 SP#2 N:B3 2x4 SP SS: DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 , Webs 2x4 SP#3:W6 2x4 SP#2 N: nC Wind loads and reactions based on MWFRS. Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Left cantilever is exposed to wind �- �• The following members need concentrated loads at the heel:0-0-0 span/setback member on the 1-3-8 cant side requires 16 lbs and the 0-0-0 span/setback member on the 1-3-8 cant side requires 16 lbs. Sub-fascia beam assumptions:0-0-0 sub-fascia beam on the 1-3-8 cantilever side.0-0-0 sub-fascia beam on the 1-3-8 cantilever side. Hipjack supports 8-3-8 setback jacks with 1-3-8 cantilever one face;1-3-8 cantilever opposite face. Deflection meets L/360 live and L/240 total load.Creep Increase factor for dead load is 1.50. r 4'8-1/8" -I R=404# U=123# NAILED M 12 4.24 p N 2 1113X6 W6 ,5X1 l` v 83 =4X8. ;3X5 FIM I W2 3X4(81 B2 JUJW2 1113X4(R) `11 W 1 6 1'9-7/8" B1 2'5-5/16" 2'2-9/16" `.9/1 F" 11-3/8" 57-7/8" rL- 11'8-11/16" R=702# U=108# W=11-5/16" R=446# U=24# NAILED (Rigid Surface) DESC.= HJ8B SEQ= 961507 PLT.TYP:WAVE yyD��IIEppMNN��CR1T=FBC2014RESRP42007FT/RT=20%(0%y0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.5000 1 Ruti�ji_b RE RF EXTREME CARE IN FAbRIGAI ING,HANDLING,SHIPPING,INSTALLING AND BRACING. 4REFERTO$CSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA 22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS.UNLESS OTHERWISE INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A TC DL 15.Opsf DATE 01-27-2017 �(, ��pr••y� �y PROPERLY ATTACHED RIGID CEILING. ����L;�cRg 51�,� "IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRW G _ ,Jb3; - +� COINCN ORMANtSHALL °E WIT BE TH TPP ONSIBLE FOR R FABRICATING HANDLING,SHDEVIATION IPPING,NHGSINSTALLIN BRACING DESIGN;ANY FAILURE TOFB RILD THE USSES.TRUSS IN DESIGN BC LL O.Opsf CM �•^+ +�~•`+'' �e�+'+*�%{' +.> PLATES CONFORMS A EMITH AD OF 2018/ 16GA(W,HISSfK)A TM(NATIONALCABLE PROVISIONS OF NDS653 GRADE 0/0(W,KIH,SS)GALVBY AS EEL.APPLY PLATES TOAND TPI.ALPINE CONNECTOR TOT•LD• 55.Opsf 0/A LEN. 110811 `3.' r c pm)9':5 33°1 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY xTSa::z"954j 17itrwf.'r) INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 SU. 8 N.W Z;16 TZMPACEM DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT �•,) Fa �`y z}sr,� ,53.E DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" HIP JACK BUILDING DESIGNER PER ANSI/TPI 1 SEC.2. TYPE Job:(17HS009)/HJ4 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,18.53 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT ll,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS. Webs 2x4 SP#3 Lumbar value set"138"uses design values approved 1/3012013 by ALSO Left cantilever is exposed to wind The following members need concentrated loads at the heel:3-0-0 span/setback member on the 1-3-8 cant side requires 16 Sub-fascia beam assumptions:3-0-0 sub-fascia beam on the 1-3-8 cantilever side.3-0-0 sub-fascia beam on the 1-3-8 lbs and the 3-0-0 span/setback member on the 1-3-8 cant side requires 16 lbs. cantilever side. Hipjack supports 4-1-8 setbackjacks with 1-3-8 cantilever one face;1-3-8 cantilever opposite face. Deflection meets U360 live and L/240 total load.Creep increase factor for dead load is 1.50. ,# 1' t Y f 34-11/16" R=124# U=29# NAILED 12 T1 4.24 p 1112X4 `v cy N M (V 3X4(81 W1 is 1112 4 f 1'9-7/8" B1 5'9-15/16" R=450# U=65# W=11-5/16" R=20/-12# NAILED (Rigid Surface) DESC.= HJ4 SEQ= 960983 PLT.TYP:WAVE DESIGN CRfr-FBC2014RESMI.200TFT1RT-20%(0%y0(0) QTY=4 TOTAL=4 REV. 16.01.01D.0710.12 SCALE=1.0000 .. R N .. INSTALLING AND BRACING. REFER 70$CSI BUILDING COMPONENT SAFETY INFORMATION PUBLISHED( D BY TPI(TRUSS PLATE INSTITUTE,p w ), (TC ,63 TC LL 30.Opsf REF 216 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE �,?;. ��t�, y INDICATED,TOPICHORD SHALL HAVE PROPEFOR SAFETY ICES PRIOR TO RLY ATTACHED STRUCTURNG THESE AL PANELS AND ONS. UNLESS TTOM CHORD SHALL A ISE TC DL 15.Opsf DATE 01-27-2017 T, ''t'8 PROPERLY ATTACHED RIGID CEILING. 't' 'IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRWG ;,7' 9 X T,•'^'�5�,sq:Sfi,Yx�'ra3 INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN Dun CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING 8 BRACING OF TRUSSES. DESIGN BC LL O.Opsf CM CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20118116GA(W,HISS/K)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 50915 '.e'lc A"VNIRM33&.1 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-7-ANY ' Ir'r9.XI14,4.540 g7b4 . INSPECTION OF PLATES FOLLOWED BY(I)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#: 17HS009 o='1'4.V4?.vgyh Tza*rt}im DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT k"t.1$:fF4$Y7L7�7a`pS F3+FE„f31P ?6 DESIGN SHOWN.THE SUITABILITY ANSI/TPI ISEUSZ OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0° TYPE HIP JACK Job:(17HS009)/HJ3 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 611/2013) Special loads —(Lumber Dur.Fac=1.25/Plate Dur.Fac=1.25) Top chord 2x4 SP#2 N TC-From 0 pif at-1.97 to 92 plf at 0.00 Bot chard 2x4 SP#2 N TC-From 2 pif at 0.00 to 2 plf at 4.09 Webs 2x6 SP SS BC-From 2 plf at 0.00 to 2 pif at 4.09 :Lt Level Return 2x4 SP#3: TC-71.49 Ib Conc.Load at 1.33 BC-36.64 Ib Conc.Load at 1.33 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC 170 mph wind,15.00 It mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT ll,EXP B,wind TC Wind loads and reactions based on MW FRS. DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 1 �r Left end vertical exposed to Wind pressure.Deflection meets L/360. Truss passed check for 20 psf additional bottom chord live load In areas with 42"-high x 24"-wide clearance. Deflection meets U360 live and U240 total load.Creep increase factor for dead load is 1.50. Bottom chord checked for 10.00 psf non-concurrent live load. t 'f j= 37-5/8" �{ R=57# U=16# NAILED 12 4.24 p T1 1112X =2X4(R T =3X4 6' M 1 co o C? io io W1 (V 1112X4 61 �•--1'11-11/16" 41-1/8" j R=220# U=12# RL=74# W=9-1/2" (Rigid Surface) R=76# U=7# NAILED DESC.= HJ3 SEQ= 960825 PLT.TYP:WAVE ry•DyESSIGNN��CRrT-FBC2014RE&RPI-2007FT/RT•20%(0%y0(0) QTY=2 TOTAL=2 REV. 16.01.01D.0710.12 SCALE=0.5000 TRUSSES R_QUII1-EXTREME CARE IN SHIPPING,INSTALLING AND BRACING. REFERTO$'CSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF I 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)ND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE tiw. ) /r'G >>' LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 .,u, 2,� INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. BC DL 10.0 sf DRWG T�� �"��-..•�u. �gy� --IMPORTANT-- FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, p atdyni Evt _^w- IN COINCN RMANCE WITH TPPSHALL NOT BE RESONSIBLE OR FABRICATING, ON HANFOR ANYDLING,SHIPPING,INSTALLING 8 ILURE BFROM THIS DESIGN;ANYRACING OFT RILD USSES.THETRUSS DESIGN BC LL O.Opsf CM '`-��_! ;n..` ..;,; �,;.,•%�' CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20118/16GA(W,HISS/K)ASTM A653 GRADE 40160(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 40102 iYiS c �4?S3E3 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY PA.91"ZO 9744999 INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DU R.FAC. 1.25 JOB#:17HS009 31211 M.G3:166 T=,Af= DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT ;iR3gtpzul�yer±,jr;�+��y3�� DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" HIP JACK BUILDING DESIGNER PER ANSIITPI 1 SEC.2. TYPE u I� Job:(17HS009)/HJ1 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT II,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Bottom chord checked for 10.00 psf non-concurrent live load. Webs 2x6 SP SS :Lt Level Return 2x4 SP#3: Deflection meets U360 live and L/240 total load.Creep increase factor for dead load is 1.50. by i .t Lumber value set"1313"uses design values approved 1/30/2013 by ALSC w" Wind loads and reactions based on MWFRS with additional C&C member design. Ste' Left end vertical not exposed to wind pressure. 11-13/16" R=-29# U=35# NAILED 12 4.24 p T1 1112X4 =2X4(R T -3x4 N a °o iV o, M 1 N v (V W1 FMN 13 81 1'5-5/16" �{ t= 1'111-11/16" )j R=151# Rw=224# U=62# RL=39/-27# W=9-1/2" (Rigid Surface) R=18/-9# U=9# NAILED DESC.= HJ1 SEQ= 961779 PLT.TYP:WAVE ryDESIGNCRIT"FSC2014REWPI-2007FT/RT"20k(O%y0(0)CARE IN FABRICATINGQTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=1.0000 �+ REFER 70 SCSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF �'"�j•�''jF., 218 NORTH LEE STIR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE y;1•x`4 J7'� !f`�•"15>,a LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE �t TC DL 15.Opsf DATE o1-27-zot7 INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURE PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. 'IMPORTANT" FURNISH COPY OF THIS DESIGN TO_INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRWG INC. F�3_k�+ `? '• -t � IN CON ORMANCE WITH TPPSHALL NOT BE RESONSIBLE OR FABRICATING,HANDLING,SHFOR ANY DEVIATIONO PING,INSTALLI G&BRACING OFTHIS DESIGN;ANY FAILURE TOT RILD USSES.THETRUSS DESIGN BC LL O.Opsf CM CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR y`°'+1 PLATES ARE MADE OF 20118/16GA(W,WSS/K)ASTM A653 GRADE 40160(W,KIH,SS)GLV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 10505 IMLA 1964-�T:+-�5^s°v3, EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY ^ 'a'r,iz2,°"'sf-.j 0744.i'A INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#: 17HS009 51l.G;!T,L-0j,26Y14 TAT3.Fi9S= DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIDR 1 2 OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE BUILDING DESIGNER,PER ANS fTPISEC. SPACING 24.0" TYPE HIP JACK Job:(17HS009)/P1 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,21.48 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT Il,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psi.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. Lumber value set"l 3B"uses design values approved 1/30/2013 by ALSC Bottom chord checked for 10.00 psf non-concurrent live load. See DWG VAL180101014 for valley details. Deflection meets L/360 live and L/240 total load.Creep increase factor for dead load is 1.50. MWFRS loads based on trusses located at least 21.48 ft.from roof edge. _=3X4 12 6 T1 T1 i+1 2X4(D8R @ 2X4(D8R) 3T 3'10" B1 R=127pif U=100p1f RL=7/-7pif W=3'10" (Rigid Surface) DESC.= P1 SEQ= PLT.TYP:WAVE DESIGN CRR8 =FBC2014RES/rP1-2007 QTY=9 TOTAL=9--TMMF,5 REDONE REV. 16.01.01D.0710.12 SCALE 9=1.0000 R N '• I=XFREME CARE IN FABMD=.TTANDLING,SHIPPING,INSTALLING AND BRAGINU. REFER 70�CSI BUILDING COMPONENT SAFETY TY INFORMATION PUB LISHED BY TPI T ). (TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF 218 NORTH LEE NTR.,SUITE SA ALEXANDRIA,VA.PRIOR AND WTCAPERFORMING (WOOD TRUSS COUNCIL OF AMERICA,ER ENTERPRISE TC DL 15.Opsf .:4 r N T 't/, -�'f•�: LN,MADISON,WI 53779)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE DATE 01-27-2017 t INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. 317W ?A '*IMPORTANT'* FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRWG INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN O.Opsf CM 1''f'' '�_z '�_"^`• ✓•) CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES. DESIGN BC LL CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20118/16GA(W,WSS/K)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 31000 t�. c s�Sai'4 7r30v" EACH FACE OF TRUSSAND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY "954j 974;91+'a INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 .7'YZ W.W. 3k'rMAr.-S DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT 1*?')kt6FAa-'•ILS2 DESIGN N SHOWN.THE AS R 2 SUITABILITY ANDUSOF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" TYPE VAL Job:(17HS009)/P2 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,21.38 ft mean hgl,ASCE 7-10,CLOSED bldg,Located anywhere In roof,RISK CAT II,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional CBC member design. Lumber value set"l3B"uses design values approved 1/30/2013 by ALSC Bottom chord checked for 10.00 psf non-concurrent live load. See DWG VAL180101014 for valley details. Deflection meets L/360 live and L/240 total load.Creep increase factor for dead load is 1.50. f MWFRS loads based on trusses located at least 21.38 ft.from roof edge. r 1'6" 10" T 12 =3X4 1 6F,- T1 T1 1 @ 2X4(D8R) 0 JL 3-112* 8R) 3'10" B1 R=127plf U=100plf RL=6/-6plf W=3'10" (Rigid Surface) DESC.= P2 SEQ= 961813 PLT.TYP.WAVE ryDyEpSIGNCRIIT-FBC2014RESITPI-2007FTIRT"20%(0%y0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=1.0000 Y,�>.•,.,y�� REFERNbESRE IRE EXIHEME CARE IN FABRICATING,HANDLING,SHI PPING,INSTALLING AND BRACING. SCSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF r 218 NORTH LEE STIR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE N,MADISON,WI FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE I .�=�.,.-...;r_.,.,,..,.�__:.-._•,.�%:����.?;.., NDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A TC DL 15.Opsf DATE 01-27-2017 5�.yp 3r-ti� PROPERLY ATTACHED RIGID CEILING, BC DL 1 O.0 Sf IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, p DRWG ,;'i,j ¢s INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN O.Opsf CM " 1^� •x'+ ' ✓y �'R' CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING 8 BRACING OF TRUSSES.DESIGN BC LL -`w.,,-.. -„�•%•F'•••.,�,SF � %” CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20/18/16GA(W,FUSS/K)ASTM A653 GRADE 40/60(W,N/H,SS)GALV.STEEL.APPLY PLATES TO TOT-LD. 55.Opsf O/A LEN. 31000 ':tV X c EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A•Z.ANY r3+E i1,954)9i>+-iC967fi INSPECTION OF PLATES FOLLOWED BY(I)SHALL BE PER ANNEX A3 OF TPI 1.2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 a12G:`f.VJ 3,*ii:fj!t ,g,jq,p�a DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT n� 8.4P ti ty 2W' �i "�R DESIGN SHOWN. THE SUITABILITY A SEC.2. OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" TYPE VAL i Job:(17HS009)/V8 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.31 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 4.50 ft from roof edge,RISK CAT ll,EXP B, Top chord 2x4 SP#2 N wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bol chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. Webs 2x4 SP#3 Lumber value set"136"uses design values approved 1/30/2013 by ALSC Bottom chord checked for 10.00 psf non-concurrent live load. See DWG VAL180101014 for valley details. Deflection meets L/360 live and L/240 total load.Creep increase factor for dead load is 1.50. t_ 4 4' _I =4X5 12 6 T1 N T1 W1 2X4(D8R) 0 8R) 1112 4 8' B1 R=113pif U=100plf RL=-6plf W=8' (Rigid Surface) DESC.= V8 SEQ= 960992 PLT.TYP:WAVE yyDyyESSIGNCRIIT=FBC2014RES7rPI.2007FTIRT=20%(0%y0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=1.0000 TRUSSES HE UIRE E REFERN�O SCSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY XIREMt CARE:IN FABRICATING, TPI(TRUSS PLATE INSTITUTE,SHIPPING,INSTALLING AND TC LL 30.Opsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE j;;Y a;9`•y,}��r�,sr'"i}"`'�,,,. LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE TC DL 15.Opsf DATE 01-27-2017 f?;1..,...,•.:r.,....., ,,,.,,,, ..,�„,,:,^T,;: a INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A 1N yP PROPERLY ATTACHED RIGID CEILING. BC DL 1 O.O Sf "IMPORTANT” FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, P DRW G 'S3'S•t+,Ll �v�^aa' Yh ..C'#:t INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN O.Opsf CM CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES. DESIGN BC LL CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20118116GA(W,H/SS/K)ASTM A653 GRADE 40/60(W,KIH,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 8 EACH FACE OF TRUSS AND,UNLESS 1rA'�i a:95Q�b-'d."o INSPECTION OF PLATES FOLLOWED BYT(1)SHALL BE PER ERWISE EANNEX A3 OF TPD ON THIS GN2002 SEC. PER SEAL OIN THIS NGS OA-Z.ANY aDRAWINGINDICATES ACCEPTANCE OFPROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DUR.FAC. 1.25 JOB#:17HS009 yY�1l� ���.111133'iD:iF DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE 3 !8<4IVLYZ??c'•�.A`fiT+�1c f�1R1�L BUILDING DESIGNER PER ANSI/TPIISEC.2. SPACING 24.0 TYPE VAL Job:(17HS009)/V4 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.81 fl mean hgt,ASCE 7-10,CLOSED bidg,Located anywhere in roof,RISK CAT Il,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bol chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. Lumber value set"l 3B"uses design values approved 1/30/2013 by ALSC Bottom chord checked for 10.00 psf non-concurrent live load. /n See DWG VAL180101014 for valley details. Deflection meets L/360 live and L/240 total load.Creep increase factor for dead load is 1.50. f 2' —2- 12 =3X4 6 T1 T1 i 2X4(D8R @ 2X4(D8R) 4' 81 R=113plf U=100plf W=4' (Rigid Surface) DESC.= V4 SEQ= 960995 PLT.TYP.WAVE EXTREME CARE IN FABRICATING,HA SHIPPING,, NST LUNG AND BRACING. yDyESSIGNCRIT-FBC2014REMP1-2007FT/RT-20%(0%y0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=1.0000 REFEM$CSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 3O.OpSf REF 218 NORTH LEE.a 4, �r ay LN,MADISON,WI 53719)OR SASUITE FETY PRACTICE PRIOR TO PERFOAND WTCARMING NGOTHESE FUNCTIONS. UNLESSD TRUSS COUNCIL OF IOTHERW OT6300 HERWISE :..„.,:,,q7,�y'r.,;;, ���,,;,�,L^ a,+k,q INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A TC DL 15.Opsf DATE 01-27-2017 gtr �7,P;�ti PROPERLY ATTACHED RIGID CEILING. BC DL 1 OO Sf x�f' s,r e. "IMPORTANT'* FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, . P DRW G _y +5 �7�,y�•�. INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN _�^-7: +• � +�= %� CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES.DESIGN BC LL O.Opsf CM •=..y ( `,M•-° "�:;,,, ” CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20118116GA(W,HISS/K)ASTM A653 GRADE 40160(W,KIH,SS)GALV.STEEL.APPLY PLATES TO TOT-LD. 55.Opsf O/A LEN. 4 t1 i!c 9: 3 A°ik EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY ^ in'Fxxz Vis:)0742.M INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 5:2Ci:i.1Fd..li?hTMP 1gT;tiR DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT �vgg,�1a ryty agg���n 3it5� DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" VAL BUILDING DESIGNER PER ANSI/TPI 1 SEC.2. TYPE Job:(17HS009)/MV12 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,16.35 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 9.00 ft from roof edge,RISK CAT II,EXP B. Top chord 2x4 SP#2 N wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. Webs 2x4 SP#3 Right end vertical not exposed to wind pressure. f Lumber value set"136"uses design values approved 1130/2013 by ALSC C' Bottom chord checked for 10.00 psf non-concurrent live toad. Deflection meets U360 live and U240 total toad.Creep Increase factor for dead load is 1.50. 4(j MWFRS loads based on trusses located at least 16.35 ft.from root edge. See DWG VAL180101014 for valley details. 1112X4 T1 12 6 W2 1112X4 io W1 p 2X4(DBR) I X4 114 12' B1 R=113plf U=100plf RL=11/-3pif W=12' (Rigid Surface) DESC.= MV12 SEQ= 960862 PLT.TYP:WAVE yOrSIGNN�CRIT-FBC2014RESrrPI-2007FT/RT=20%(0%v0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.5000 SHIPPING.INSTALLING AND BRACING. REFER TO SCSI(BUILDING COTRUSSRFONENT SAFETY INFORMATION),PUBLISHED BY MPTPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF y, 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE ,�.=.,:,•,.; •..�.,,,;`,C�r,;,, {5, ",',any INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A TC DL 15.Opsf DATE 01-27-2017 gl:;yp��� ,yTv�l PROPERLY ATTACHED RIGID CEILING. + rUO s.tlnec •IMPORTANT• FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRW G i" '"`j INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES.DESIGN BC LL O.Opsf CM ""••+�,1_ ,',,, CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20/1811 GGA(W,WSS/K)ASTM A653 GRADE 40/60(W,K H,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Opsf O/A LEN. 12 i %'t c i9'�33 S+7✓-a'43°3 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY • FArci'.k Q M-1,199*9 INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17 S009 5 V^.W,,366 TMP DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT �• 8i1 a�TtY� '' � '�� `� DESIIGNS OWN.THE PER SUITABILITY I1SE2 USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THEBUILDISPACING 24.0" ITYPE VAL G i• t" • Job:(17HS009)/MV10 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,16.85 ft mean hgt,ASCE 7-10,CLOSED bldg,not located within 9.00 ft from roof edge,RISK CAT Il,EXP B, Top chord 2x4 SP#2 N wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/_)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. Webs 2x4 SP#3 Right end vertical not exposed to wind pressure. ri Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Bottom chord checked for 10.00 psf non-concurrent live load. i J Deflection meets U360 live and L/240 total load.Creep increase factor for dead load is 1.50. MWFRS loads based on trusses located at least 16.85 ft.from roof edge. See DWG VAL180101014 for valley details. 1112X4 T1 6 � 1112X4 W2 in W1 v 2X4(D8R) I X4 1112X4 10' 81 R=113plf U=100plf RL=11/-3plf W=10' (Rigid Surface) DESC.= MV10 SEQ= 960859 PLT.TYP:WAVE ry(DyESSIIGN�CRIr-FBC2014RESRPI-2007 FT/RT-20%(0%y 0(0) QTY=1 TOTAL=1 REV. 16.01.01D.0710.12 SCALE=0.5000 `,,�,="'�•-,� REFER TSHIPPING,INSIALLING AND URAGINU. O SCSI(BUILDING COMPONENT SAFETY INFORMATION),PUBTRUSSES REQUIRE EXTREME CARE IN LISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.Opsf REF ( 1�•� 218 NORTH LEE STIR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISE TC DL 15.Opsf INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A P DATE 01-27-2017 PROPERLY ATTACHED RIGID CEILING. _11` `11 "IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.0psf DRWG INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES. DESIGN BC LL 0.0psf CM ""_•"•.,,., ,,,,,,w^"``"+�w;,,,,, "„r°' CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR ^+• PLATES ARE MADE OF 20/18116GA(W,H/SS/K)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO I'CiLc POO°?�at'3✓1 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY TOT•LD. 55.Opsf O/A LEN. 10 ?7YriAa:3 INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 alyz P4"Trd,IEdh TZPF'3,fm DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT 1-33"FiAN4)i3::'S.�atfi' "�D `• DESIGNS DESIGNER, ERITABILITY AND ANSI/TPI 1 SEC2USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THEBUILDISPACING 24.0" ITYPE VAL t� I - Job:(17HS009)/MV8 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 611/2013) 170 mph wind,15.00 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT ll,EXP B,wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCp)(+/-)=0.18 Top chord 2x4 SP#2 N Bot chord 2x4 SP 92 N Wind toads and reactions based on MWFRS with additional C&C member design. Webs 2x4 SP#3 Right end vertical not exposed to wind pressure. } Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Bottom chord checked for 10.00 psi non-concurrent live load. �L` Deflection meets U360 live and U240 total load.Creep Increase factor for dead load is 1.50. 1 See DWG VAL180101014 for valley details. MWFRS loads based on trusses located at least 15.00 ft.from roof edge. 1112X4 T1 12 6 P sr W1 8R) 4 8' B1 R=113plf U=100pif RL=10/-3pif W=8' (Rigid Surface) DESC.= MV8 SEQ= 960856 PLT.TYP:WAVE yyOFpSSIGNNN��CRIT=F8G20I4R£SrrP6 )< 2007FT/RT-20%(0% 0i0) QTY=2 TOTAL=2 REV. 16.01.01D.0710.12 SCALE=0.7500 REFER 70 BCSI(I FtUbbE5 REWIRE EXTREME CARE IN FABRICATING,HANDLING,SHIPPINQ.INS IALLINU AND BRACING. BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30•apstREF yr sp 218 NORTH LEE STR.,SUITE 312,ALEXANDRA,VA 22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN,MADISON,W153719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS.UNLESS OTHERWISE INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A TC DL 15ApS DATE 01-27-2017 ;s:....•u: �.•�.'.�•.>._.:• v BC DL 10.Qpsf DRWG W��r�, ��+� PROPERLY ATTACHED RIGID CEILING. IT 'rM -124 -IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, rp ,p*�«; r, —,y7� •.� a. INC„SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN ,r iS _ .� CONFORMANCE WITH TPI;OR FABRICATING.HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES.DESIGN BC LL 0.0ps CM CONFORMS t .•-^'`t"""-�.,,,,,,,�, PLATES ARE MIADE OF TH 20181 6GA(W,WSS/K)A TM(NATIONALBLE PROVISIONS OF NOS653 GRADE 40/0(W,KIH,SS)GALV.6 EEL.APPLY PLATES TOAND TPI.ALPINE CTOR TOT.LD. 55.Opsf O/A LEN. e R � "VIA, 1�;075--'3^38'3 EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY ,n :b`.2;iso 074'S'. I.3 INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 ri .7�3it TaSBFtat a aA26:'I 1; DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT 9,.4:r.�4"Qd'Y a3 4c DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" TYPE VAL BUILDING DESIGNER PER ANSIITPI 1 SEC.2. iF Job:(17HS009)/MV6 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.23 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT 11,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/_)=0.18 Bot chord 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. Webs 2x4 SP#3 Lumber value set"13B"uses design values approved 1/30/2013 byALSC Right end vertical not exposed to wind pressure. Deflection meets U360 live and U240 total load.Creep Increase factor for dead load is 1.50. Bottom chord checked for 10.00 psf non-concurrent live load. MWFRS loads based on trusses located at least 15.23 ft.from roof edge. See DWG VAL180101014 for valley details. 1112X4 T1 12 6 t7 W1 8R) 1113X5 6' B1 R=113plf U=100plf RL=10plf W=6' (Rigid Surface) DESC.= MV6 SEQ= 960853 PLT.TYP:WAVE �yDESIGN CRR=F8C20I4RESRPI-2007FT/RT=20%(0%y0(0) QTY=2 TOTAL=2 REV. 16.01.01D.0710.12 SCALE=1.0000 Rt�(N TRUSSES HL:QU1I F EXTREME CAREIWMRICATING,HANDLING,SHIPPING,INSTALLING AND BRACING. x�,..-..w":-.•.,�• R " SI(OgCBUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, TC LL 30.0psf REF 218 NORTH LEE STIR.,SUITE 312,ALEXANDRIA,VA 22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE NDICAT DISCED. LL SHALL HAVE P OPERLY ATTACHED STRUOCTUIRALFOR SAFETY PRACTICES PRIOR TO NG TPANELS ANDHESE TBOTT MNCHORD SHALESS LwHAVE A ISE TC DL 15.Opsf DATE 01-27-2017 PROPERLY ATTACHED RIGID CEILING. '*IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.0psf DRWG ,p?. y.�*'� l,, n H ^AgNt INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN ' ; 167MC" TRIM'S''ISI` CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES. DESIGN BC LL O.Opsf CM f "";�«°"'� "•"=�' CONFORMS WITH APPLICABLE PROVISIONS OF NDS NATIONAL DESIGN SPEC,BY AF&PA AND TPI.ALPINE CONNECTOR �,�~"` 7"� ��•�""v '" -1 PLATES ARE MADE OF 20118116GA(W,HISSIK)ASTM A653 GRADE 40/60 (W,KIH,SS)GALV.STEEL.APPLY PLATES TO TOT,LD. 55.Opsf O/A LEN. 6 10.ffA 6T1+4; f' K EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#:17HS009 al?X;3 tv;:1:>?:tr TkT.ki.P.ta31 DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIGN SHOWN. OWN.THE SUITABILITY AND ANSI PI 1 SE2USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE BUILDING SPACING 24.0" ITYPE. VAL Job:(17HS009)/MVA THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/1/2013) 170 mph wind,15.73 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT II,EXP B,wind TC DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Top chord 2x4 SP#2 N Bot chord 2x4 SP#2 N Wind toads and reactions based on MWFRS with additional C&C member design. Webs 2x4 SP#3 Bottom chord checked for 10.00 psf non-concurrent live load. � Lumber value set"136"uses design values approved 1/30/2013 by ALSC ` Deflection meets L/360 live and U240 total load.Creep Increase factor for dead load is 1.50. (( See DWG VAL180101014 for valley details. MWFRS loads basad on trusses located at least 15.73 ft.from roof edge, 1112X4 12 T1 6 (% N W1 y 8R) 1112X4 B1 R=113ptf U=100plf RL=9plf W=4' (Rigid Surface) DESC.= MV4SEQ= 960850 PLT.IYP.-WAVE yyDESIGN CRIIIT-FOC2014RESFTPI-2007FT1RT"20%(0%YCIO) QTY=3 TOTAL=3 REV. 16.01.01D,0710.12 SCALE=1.0000 SES,a�,•• REFERN7`O BOSi(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI( TRUSS PLATE INSTITUTE, TC LI-SHIPPTNG,INSTALLING AND BRACING. 3O'OPSf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA.22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS.UNLESS OTHERWISE TC DL 1 S.O�}Sf DATE 01-27-2017 INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING. BC DL 1O.OpSf DRWG ••IMPORTANT" FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, m• �1, +� 1. INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN BG LL 5QPSf CM t4;.tces.�j .fS 7M CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING 8 BRACING OF TRUSSES.DESIGN CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AFBPA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20118116GA(W,H/SS/K)ASTM A653 GRADE 40/60(W,KIH,SS)GALV.STEEL.APPLY PLATES TO TOT.LD. 55.Q[JSf O/A LEN. 4 't ldyA%AVI�yI;�? ••3'�F33r EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY F'e'A.'1:454)V74.4�'D INSPECTION OF PLATES FOLLOWED BY(1)SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR,FAC, 1.25 JOB#:17HS009 Ydb N.W.1:1611RUtP'ttJ"m DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT .�'t S8•.gFc"i�T;�ZF.T,-'ati�'ciw �3t#i� DESIGN SHOWN.THE SUITABILITY AND USE OF THIS COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE SPACING 24.0" TYPE VAL BUILDING DESIGNER PER ANSUTPI 1 SEC,2. a Job:(17HS009)/MV2 THIS DWG.PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Value Set:13B(Effective 6/112013) 170 mph wind,16.23 ft mean hgt,ASCE 7-10,CLOSED bldg,Located anywhere in roof,RISK CAT II,EXP B,wind TC Top chord 2x4 SP#2 N DL=5.0 psf,wind BC DL=5.0 psf.GCpi(+/-)=0.18 Bot chard 2x4 SP#2 N Wind loads and reactions based on MWFRS with additional C&C member design. f j Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Bottom chord checked for 10.00 psf non-concurrent live load. See DWG VAL180101014 for valley details. Deflection meets U360 live and L/240 total load.Creep increase factor for dead load is 1.50. MWFRS loads based on trusses located at least 8.11 ft.from roof edge. 12 6 T1 g2X4(DBR 1 2' B1 R=113pif U=100p1f RL=11plf W=2' (Rigid Surface) DESC.= MV2 = PLT.TYP:WAVE ��OEgqSIGNCRIT=FBC2014RESRPI$007FTRT=20°k(0°hv0(0) QTY=4 TOTAL=4 REV160101D.0710.12 SEQ 960847 . . . SCALE=1.0000 REFETRUSSES REQUfRE_EXI RPME CARE IN FABRICA1 ING,HANDLING,SHIPPING,INSTALLING AND BRA ING. RNBCSI(BUILDING COMPONENT SAFETY INFORMATION),PUBLISHED BY TPI(TRUSS PLATE INSTITUTE, C TC LL 30.Opsf REF 218 NORTH LEE STR.,SUITE 312,ALEXANDRIA,VA 22314)AND WTCA(WOOD TRUSS COUNCIL OF AMERICA,6300 ENTERPRISE Us` 7 i;t;f,F. �. 7.;�,• LN,MADISON,WI 53719)FOR SAFETY PRACTICES PRIOR TO PERFORMING THESE FUNCTIONS. UNLESS OTHERWISEDATE 01-27-2017 ;a= :••,��..'•.�,..•,:..=.. ,,.r;;.tti,.i:'�,.,.:';.=,�,a INDICATED,TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL PANELS AND BOTTOM CHORD SHALL HAVE A TC DL 15.Opsf 'it �a'�.•y),g14r;� PROPERLY ATTACHED RIGID CEILING. - .S '+.F..Y+,•=Geoc+ "IMPORTANT' FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR.ALPINE ENGINEERED PRODUCTS, BC DL 10.Opsf DRWG INC.,SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN;ANY FAILURE TO BUILD THE TRUSS IN BC LL O.Opsf CM �""� �• _-'4^ �'••r'3' CONFORMANCE WITH TPI;OR FABRICATING,HANDLING,SHIPPING,INSTALLING&BRACING OF TRUSSES. DESIGN CONFORMS WITH APPLICABLE PROVISIONS OF NDS(NATIONAL DESIGN SPEC,BY AF&PA)AND TPI.ALPINE CONNECTOR PLATES ARE MADE OF 20118/16GA(W,H/SSIK)ASTM A653 GRADE 40/60(W,K/H,SS)GALV.STEEL.APPLY PLATES TO TOT,LD. 55.Opsf O/A LEN. 2 3"f3SF i a7�i 3.�$% EACH FACE OF TRUSS AND,UNLESS OTHERWISE LOCATED ON THIS DESIGN,POSITION PER DRAWINGS 160A-Z.ANY avlXz$?454)v7P'Mo INSPECTION OF PLATES FOLLOWED BY(q SHALL BE PER ANNEX A3 OF TPI 1-2002 SEC.3.A SEAL ON THIS DUR.FAC. 1.25 JOB#: 17HS009 .11156�'.cZIMAT—m DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT 11M'aFA`,L"T')UUAAME4FLXM514 DESIGNSHOWNNERESUIIANSRPI�ECS2OFTHISCOMPONENTFORANYBUILDINGISTHERESPONSIBILITYOFTHE SPACING 24.0" TYPE VAL ANCHORAGE AND RESTRAINT OF LATERAL BRACING THIS IS A DANGEROUS CONDITION THE DRAWING BELOW (FIG. 3B) SHOWS HOW TO RESTRAIN THE CONTINUOUS LATERAL BRACING (CLB —M), WHEN ANCHORAGE SHEATHING FIG. 1 IS NOT AVAILABLE AS SHOWN IN FIG. 2 THE DIAGONAL COMPRESSION WEBS, TO PREVENT THIS BRACE RESTRAINT (DBR — ) MEMBERS ARE 2X4'S, 1 1 BEFORE AND AFTER FAILURE, ANCHOR THE ENDS OF WHICH ARE ATTACHED TO TOP & BOTTOM 1 1 BUCKLING. OR RESTRAIN THE CHORDS. THE DIAGONAL BRACE MAY BE ATTACHED.DIRECTLY TO 1 I I 1 I LATERAL B AIN-1 THE CLB OR TO THE WEB OPPOSITE THE CLB. USE THE SAME NAILING SHOWN IN FIG. 3A. II II II CONTINUOUS LATERAL BRACING I 1 I (CLB) MAINTAINS SPACING, BUT USE METHOD SHOWN IN I / I PERMITS LATERAL BUCKLING FIG. 2, 3A & 3B, OR OF ALL WEB MEMBERS AT ANOTHER STRUCTURALLY THE SAME TIME. SOUND METHOD SPECIFIED BY PROFESSIONAL FIG. 3B BEARING FOR TRUSSES ENGINEER OR ARCHITECT, FIG. 2 FIG. 3A ANCHORAGE BY BUBUILDINGT.ING DESIGNER DIAGONAL BRACE RESTRAINT ATNT (MjF) EXAMPLE TRUSSES (OTHER ANCHORAGE PROVISIONS WITHIN THE UNIT A & 3Bl FOR OTHER TYPES OF WALLS). SHEATHING SHEATHING $ & COMPRE93ION WEB, ANCHORAGE (BY BUILDING SLOPING OR VERTICAL DESIGNER) INTO SOLID END < OR WEB NEEDING 7 APP WALL — RESTRAINS LATERAL 480\ BRACING. U BRACING, THEREBY PREVENTING WEB BUCKLING. CLB CUB COMPRESSION WEB 2X4 X13 OR STUD GRADE DBR NAMED CEIdNG TO OPPOSITE SIDE OF WEB AND REPEATED AT APPROXIMATELY 20 FOOT CEILINGINTERVALS TO RESIST LATERAL MOVEMENT. DBR MAY TRAVERSE MORE THAN TWO ATTACH TO WEBS WITH TRUSSES, DEPENDING ON TRUSS HEIGHT. (2) 16d COMMON (0.182' X 3.6',MIN) NAILS. »WAVXING"MD AND rouoT All XOTM ON TMS MMM Tr requtm e:lreme Dare In fabrf-Un&h-d1loz-Wppb3&tn-laMns ead brady. My to sad fon— REF BRACE RESTRAINT D=(B.Maj C—Pao-t aafet feta—tfea,by 1'rt.nd TTCA)for-fair pa+dfoaa per to p f rte¢ .L°bee.D �m°'LL`mef wnb,t� a�ev b.e ayothat'edtop,+d°a'd DATE 1/1/09 . ■B3:D'f �tbb..Zro�b +fe�PW -ebfnf�t=�'ODed p`D� DRWG BRCLBANCO109 -wbmm- r==copy or ams mtmaN m,=uuA% q,FOR1RAMz PfT DuDdla,Compoaaata Oroup Tae.UMBCO)shall mt be bId fm d"ti—from thL dedso, . Building Components Group Inc. Myt-Dme}a bv0d the truce to ooafornaaw wMh TPL m fa Ums,hand!!y ahtppW,foatambg k bmdog of in—r. rraW oonua t=pfatn ere—A of m/1a/jWA(W,D/a/X)ASTM Anal v.%37/40/80 FVIUXasf )C.aWt Appjr p4tr to—14-141a of bvm podtforud u shown abon sad=)dat Dowin. ' A —LLL drawing ar omv pye bud.tm aoowt—a sad pr f-e nd etglna..tug reaponznmty ea* far the tm.a oompoaeat dadg--Lown. The aaftablfiir-�—e--f tl f oomp—t,for aqr buW1.1 V the tdDir o!the Ehdldlai Deal�aer per AN37hP[1 BM IL Earth City,MO 63045 — 'wwrStwbos.oma;TP1.rww.lpla-t.oam;%'ml www.-bdnduatrr•o=M.w A oaefe..V GENEI(®®��{{`t0 L NOTES NOT AS GENERALES HOISTING RECOMMENDATIONS FOR TRUSS BUNDLES Trusses are not marked in any way to identify Los trusses no erten marcados de ningtin modo que RECOMENDACIONES PARA LEVANTAR PAQUETES DE TRUSSES. the frequency or location of temporary lateral idendfique la frecuencia o localizaci6n de restricci6n lateral &Warning!Don't overload the sane. restraint and diagonal bracing.Follow the y arriostre diagonal temporales.Use las remmendaciones iAdvertencia![No sobrecarga la gr6a! recommendations for handling,installing and de manejo,instalaci6n,restriod6n y arriostre temporal de Never use banding alone to lift a bundle. temporary restraining and bracing of trusses. los trusses.Vea el folleto BCSI Guia de Buena PraLtica Do not lift a group of individually banded bundles. Refer to BCSI Guide to Good Practice for para el MariInstalad6n Restriod6n y Arriostre de los Handling Installing Restraining&Bracing of Trusses de Madera Conectados con Placas de Metal para Nunca use s6lo los empaques para levantar un paquell Metal Plate Connected Wood Trusses for more informad6n mos detallada. No levante un grupo de empaques individuates. detailed information. Los dibujos de dise"no de los trusses pueden especifimr las A single lift point may be used for bundles Truss Design Drawings may specify locations of localizaciones de restricci6n lateral permanente o refuerzo with trusses up to 45. ." permanent lateral restraint or reinforcement for en los miembros individuales del truss. Vea la hoja Two lift points may be used for bundles with individual truss members.Refer to the BCSI-133 resumen BMEB3-Restricd6n/Arriostre Permanente cle trusses up to 60'. 16 Warning!Do not over load suppottinc Summary Sheet-Penman n R train/Bra'ng Cuerdas v Miembros Secundarios para mer informad6n. Use at least 3 lift points for bundles with structure with truss bundle. of Chords&Web Members for more information. EI resto de los dise"nos de arriostres permanentes son la trusses greater than 60'. iAdvertencia!No sobrecargue la este All other permanent bracing design is the responsabilidad del Dise5ador del Edificio. responsibility of the Building Designer. Puede usar un solo lugar de levantar para apoyada con el paquete de trusses. paquetes de trusses hasta 45 pies. �j Ai, The consequences of improper handling,erect- ,gyp a Puede usar dos puntos dara e levantar pL{ Place truss bundles in stable position. mg,installing,restraining and bracing can resultpaquetes mos de 60 pies. Puse paquetes de trusses en una pos in a collapse of the structure,or worse,serious k 4 Use por to menos tres puntos de levantar para astable. personal injury or death. ,; paquetes ni de 60 pies. El resultado de un manejo,levantamiento, L��E JG "` �,, - INSTALLATION OF SINGLE TRUSSES BY HAND instalad6n,restricd6n y arrisotre incorredo puede f 1yb>� INSTALACI6N POR LA MANO DE TRUSSES INDIVIDUALES ser la caida de la estructura o a6n peor,heridos o l/l Trusses 20' - W Trusses 30'or t a W, or less,sup- less,support at t ' ort at eek. P P quarter points. 0 Banding and truss plates have sharp edges.Wear *r Levante Levante de gloves when handling and safety glasses when �"rr cutting banding. / f del pica los los cuartos trusses de de tramo los Empaques y placas de metal t enen border r 20 les o all Use uantes lentes rotectores cuando n I Trusses up to 20' -y I trusses de 30 I Trusses up to 30' 9 Y P �t _ menos. Trusses haste 20 pies pips o menos. Trusses hasty 30 pie torte IDS empaques. HOISTING OF SINGLE TRUSSES—LEVANTAMIENTO DE TRUSSES INDIVIDL HANDLING E1 P1�ii®E�1 1 �i Hold each truss in position with the erection equipment until top chord temporary lateral rest ®�C 9� .8 Lz'_I Is installed and the truss is fastened to the bearing points. Avoid lateral bending.—Evite la Flexion lateral. Sostenga cada truss en posid6n con equipo de gnia hasta que la restricci6n lateral temporal !� Use special care in Udlice cuidado cuerda superior este instalado y el truss este asegurado en IDS soportes. P•` windy weather or especial en dials near power lines ventos is o cerca de r Warning!Using a single pick-point at the peak and airports. cables electricos o de can damage the truss. aeropuertos. iAdvertencia!EI use de un solo lugar para levantar en el pito puede hater dano al truss. Spre54Z for t HOISTING RECOMMENDATIONS FOR SINGLE TRUSSES 60'or less The contractor is responsible for properly RECOMENDACIONES PARA LEVANTAR TRUSSES receiving,unloading and storing the trusses O O INDIVIDUALES at the jobsite. EI contratista tiene la responsabilidad de !._✓,{Use proper rig- Use equipo apropiado npPr° vz recibir,descar ar almacenar adecuada- gin and hoisting Tagline truss length g y g g para levantar e mente IDS trusses en la obra. equipment. im rovisar. TRussEsupro3o' p Preatler bar TRUSSES Hl 30 PIES llmi • � .e..,..1........,_.,....__ Tae-in —in Asch y? 7 ` ;� �, r „u Locate Spreader bar 10'D.C. ,\ ;: •' <'`" `� Spreader her l/2 to above or sGrfhack max. :�... •iii.s.`';."r' \; � y:a. " ..:; 2/3 truss length � mid-height :` n. ,�••.:., ;...fY-t r c c4r.^x,T Tagline �.� � •,):�;:- ''• TRUSSES UP TO TRUSSES HASTA 60. r '•',}h,�' �=-��� t '- - r t- Spreads r bar 2/3 to 3l4 Wss length V, Tagline !�If trusses are to be stored horizontally,place TRUSSES UP TO AND OVER 60' — blocking of sufficient height beneath the `7 TRUSSES HASTA Y SOORE 60 PIES stack of trusses at So to 10'on center. ® un ve not store almacene troTEMPORARY RESTRAINT & BRACING For trusses stored for more than one week, unbraced bundles verticalmente los ® �!!- ,p. �g p®p� cover bundles to prevent moisture gain but upright. trusses sueltos. ODES 13 RICCIO N Y A'9IORIOSTRE TEMPORAL L allow for ventilation. Refer to @CSI Guide to Good Practice for - r Refer to BCSI-62 Summer Sheet-Truss H nd ing Installing,Restraining&Bracing Installation&Temporary Restraint/Bracing for -<---jTop Chord Teml Of Metal Plat no ed Wood Trussed " ° more information. �� " 'ti t'✓ iteral Restrain for more detailed information pertaining to Vea el resumen BCSI B2-Restricd6nl : 2x4 min. handling and Iobsite storage of trusses. y Arriostre Temporal y Instalaci6n de IDS / i �� c" Trusses para mos informad6n. Si los trusses estaran guardados horizon- Locate ground braces for first truss directly in �i talmente,ponga bloqueando de allure line with all rows of top chord temporary lat- suhdente detras de la pila de los trusses. eral restraint(see table in the next column). =90' ® Do not store on No almacene en Coloque los arriostres de tierra para el primer Para trusses guardados por mos de Una uneven ground. tierra desigual. truss directamente en linea con cada Una de Brace first truss semana,cubra IDS paquetes para prevenir, a* _ las filas de restriction lateral temporal de la I ag--securely before aumento de humedad perp permita venti- cuerda superior(vea la table en la pr6xima erection of addi' laci6n. columna). I' trusses. Vea el folleto BCSI Guia de Buena Pr6ctica ; Do not walk on unbraced amara el Manejo.Instalaci6n Restriction kAr 'r'o tres de IDS Trusses de Madera Conectados - _-.__ trusses. con Placas de Metal para informaci6n m6s r _ No camine en trusses detallada sobre el manejo y almacenado de #' -I sueltos. IDS trusses en area de trabal s CLB WEB BRACE SUBSTITUTION T-BRACING THIS DETAIL IS TO BE USED WHEN CONTINUOUS LATERAL BRACING (CLB) OR T—BRACE IS SPECIFIED ON A TRUSS DESIGN BUT AN ALTERNATIVE 'WEB L-BRACING: OR BRACING METHOD IS DESIRED. L—BRACE APPLY TO EITHER SIDE OF WEB NARROW FACE. ATTACH WITH 10d BOX OR GUN (0.128"x 3.-,MIN) NAILS. NOTES: AT 6" O.C. BRACE IS A THIS DETAIL IS ONLY APPLICABLE FOR CHANGING THE SPECIFIED MINIMUM WEB CLB SHOWN ON SINGLE PLY SEALED DESIGNS TO T—BRACING OR SCAB MEMBER LENGTH BRACING. ALTERNATIVE BRACING SPECIFIED IN CHART BELOW MAY BE CONSERVATIVE. FOR MINIMUM ALTERNATIVE BRACING, RE—RUN DESIGN WITH APPROPRIATE BRACING. T—BRACE L—BRACE WEB MEMBER SPECIFIED CLB ALTERNATIVE BRACING SCAB BRACING: SIZE BRACING T OR L—BRACE SCAB BRACE 2X3 OR 2X4 1 ROW 2X4 1-2X4 APPLY SCAB(S) TO WIDE FACE OF WEB. 2X3 OR 2X4 2 ROWS 2X8 2-2X4 NO MORE THAN (1) SCAB PER FACE. 2X8 1 ROW 2X4 1-2X8 ATTACH WITH 10d BOX OR GUN 2 (0.128"x 3.",MIN) NAILS. X8 2 ROWS 2X8 2_2%4(#) AT 6" O.C. 2X8 1 ROW 2X6 1-2X8 BRACE IS A MINIMUM 2X8 2 ROWS 2X8 2-2X8(*) 809 OF WEB MEMBER LENGTH SCAB BRACE T—BRACE, L—BRACE AND SCAB BRACE TO BE SAME SPECIES AND GRADE OR BETTER THAN WEB MEMBER UNLESS SPECIFIED OTHERWISE ON ENGINEER'S SEALED DESIGN. (#) CENTER SCAB ON WIDE FACE OF WEB. APPLY (1) SCAB TO EACH FACE OF WEB. »WAiamiti»RW AND MUM AM Stared ON TWI tin TC LL PSF REF CLB SUBST. rrtu—rrgebe.atnone oar.1.Lbrlo.ttor.baadH-&ahIPa1W,mstam g dad br+dal• Bdrr to.ad!Dame ncSl"dta9 compon-t B+td7 b�tor Uaa,by epi ead,WrCA)ter retry ya.ottor Prior to periarmtat ITYtb.rr faeatks= bwt&Uas duIl ted•tam ta.dat Bar. aaiv WW othertdw.top abord TC DL PSF DATE I f i j09 .be8 hoe proparb ettaebai rlraatoral P+anN eaa bottom shoed.hes bei.r Pxopeab rthoLod rldd ena#on.% :By.�ibb jahr enez.iiomctor pav for��t bA"°r`0 4d p°' IStb1 BC DL PSF DRWG BRCLBSUB0109 «D@aer M- rams copy or rim Butt TO DMAUAriaN COMACM BC LL PSF SSW BaBdfa.t�ayanea{.asap fad,ttliBCp)aba8 dot b etas ay dedatlaa txom this de.ip. SuOding Components Group Inc. ay tabor+b band th.tror m ormto�m+ao+'rftl+'fP1.or t+rlaava�.naamtnit,+htpptar.lvLlBatt k TOT. LD. PSF braom;at trow.. ?IT=aomawsor phw are made of as/te/tocA(W.B/a/s)Aszu Aaea R•d:sr/ao/eo (1(1WU®n�eh}r .ted. A"pUtw to"ab Lee of b podttoaad u.hotm abs"dad oa telat Dettll& ihle dream;or sorer p.� mdioal.r gad pradedmsd enCtnerrlN rrrpoadtdBy eal+y fm•th.tees ooaipoma t dedpt ahmra. rae.att"a�"pi caeca a.a or snt.oampon�t for.mar baamas L the DUR. FAC. �et the De.1�er per AN3i i flee.W. Earth City,MG 63045 st•••u bq.00m 'c r�i:..espsaet.omal •.....bch%d=try.00m:M wwAomale.on SPACING STEPS TO SETTING TRUSSES RESTRAINT&BRACING FOR 3x2 AND 4x2 PARALLEL CHORD TRUSSES LAS MEDIDAS DE LA INSTALLACI®N DE LOS TRUSSES LA RESTRICCION Y EL ARRIOSTRE PARA TRUSSES DE CUERDAS PARALELAS 3X2 Y 4X2 ,/ 1)Install ground bracing.2)Set first truss and attach securely to ground bracing.3)Set next 4 Refer to (B I-B7 Diagonal Bracing trusses with short member temporary lateral restraint(see below).4)Install top chord diagonal Summary Sheet 10'or 15" Repeat Diagonal Bracing bracing(see below).5)Install web member plane diagonal bracing to stabilize the first five trusses Te orary&Per- every 15 truss spaces(30') oment Restrain[/ anes (see below).6)Install bottom chord temporary lateral restraint and diagonal bracing(see below). mmfor Parallel ! 7)Repeat process on groups of four trusses until all trusses are set Chord Trusses for 1)Instate los arriostres de tiers.2)Instale el primero truss y ate seguramente at arriostre de more information. 1 i tierra.3)Instale los pr6ximos cuatro trusses con restricci6n lateral temporal de miembro torte Vea el resumen (vea abajo).4)Instale el arriostre diagonal de to cuerda superior(vea abajo).5)Instale arriostre _ Apply Diagonal Brace to CSI-B7-RRstrir- diagonal para los pianos de los miembros secundarios para estable los primeros circa trusses vertical webs at end of � ci6n y Amiostre (vea abajo).65 Instate la restricci6n lateral temporal y arriostre diagonal para la cuerda inferior cantilever and at bearing All Lateral Restraints Temporal v (vea abajo).7)Repita este procedimiento en gropes de cuatro trusses hasty que lodes los trusses Permanente de locations. lapped at least two trusses. ester las oracles. T Mssea de Cu rdas *Tap chord Temporary Lateral Restraint spacing shall be Refer to BCSI-82 Summary Sheet Truss Installation&Temporary Restraint/Bracing for more Parelelas Para m6s 10'o.c.max for 3x2 chords and 15'D.c.for 4x2 chords. Information! informad6n. Vea el resumer BCSI-B2-Inctala ion de Tmsses y Arrioshe Temporal para mayor INSTALLING I�lSTALACI®N informad6n. `Out RE ,piano Tolerances FOR ALL PLANES OF TRUSSES Tolerances for Out-of-Plane. EL RESTRICCION/ARRIOSTRE EN TODOS PLANOS DE TRUSSES. (� '&Ldo P'ruw Max. Truss i LJ Tolerancias para Fuera-de-Plano. Bow Length This restraint&bracing method is for all trusses except 3x2 and 4x2 parallel chord trusses. D/5o D(ft.) Length--n- Marc Bow 3/4' 12.5' Este metddo de restricci6n y arriostre es para todo trusses excepto trusses de cuerdas paraletas 114• 1' 4X2. Max.B---- Length— L 12" 2' 7/8' 14.6' 1)TOI CHORD—CUERDA SUPERIOR Max Bow 1" 16.7' Zi Truss Span Top Chord Temporary Lateral Restraint(TCTLR)Spacing _-_-__-_ ; 3/4' 3' Ldngitud del Tramo Espaciamiento del Arriostre Temporal de la Cuerda Superior �� Leng h r 1-1/8" 18.8' Up to 30' 10'o.c.max. 1° 4 = 1-1/4" 20.8' Hasta 30 pies 10 pies maximo m I Plumb 1-1/4• 5' ' 1-3/8' 22.9' 30'to 45' 8'o.c.max. f „ Tolerances for �bob 1-112• 6' 30 a 45 pies 8 pies maximoLl Out-of-Plumb. 1-1/2" 25.0' 1-3/4' 7' 45'to 60' 6'o.c.max. Tolerancias para D/5o max 1-3/4W292'45 a 60 pies 6 pies maximo Fuera-de-Plomada. 2' z8' 60'to80'* 4'O.C.max. t 60 a 80 pies* 4 pies maximo CONSTRUCTION LOADING—CARGA DE CONSTRUCCION } *Consult a Professional Engineer for trusses longer than 60'. Do not proceed with construction until all lateral restraint and I _ R ,-patimum Stack Holgfit�• 'Consulte a un ingeniero para trusses de m is de 60 pies. �._._ _.— \y bracing is securely and properly in place. r- 4_„','fdr hUlorlal an�7russob _E_�`- i See BCSI-B2 for TCTLR options. y / No proceda con la construcci6n hasta que todas las restric- Material Height I L-I Vea el BCSI-B2 para las opciones de TCTLR. '.=_--.,��� clones laterales y los arriostres esten colocados en forma — Refer to SCSI-B3 Sum- \�� aproplada y Segura. Gypsum Board 12• i r �__—_—- \� mary Sheet-Permanent _-\�_ \`\ �� Do not exceed maximum stack heights.Refer to SCSI-B4 Plywood or OSB 16• 1 Restraint/Bracing of Chords ® Summary Sheet-Coo==a LoadinQ for more information. Asphalt shingles 2 bundles j &Web Members for Gable End Frame restraint/bradng/ ) �! \ No exceda las maximas alturas recomendadas. Vea el resumen Concrete Block s reinforcement information. i BCSI-B4 Caraa de Construcdo5n para mayor informad6n. Para informad6n sabre clay ne 3-4 files high restricci6n/arriostre/refuerzo F,/j Repeat diagonal Para armaz6n de hastial vea LL��!!braces for each set of el resumen BCST-B3-Re- 4 trusses. a� strimaneArride C Ground bracing not shown for clarity. Repita los arrisotres ® Do not overload small groups or single trusses. / Permanente de C arias. x diagonales para cada No sobrecargue pequefios grupos o trusses individuales. Miembros secundarios. grupo de 4 trusses. 2)WEB MEMBER PLANE—PLANO DE LOS MIEMBROS SECUNDARIOS ® Never stack materials near a peak. Nunca amontone material cerca del pini. ,,)L lit Place loads over as many trusses as possible. iagonal Coloque las cargas sobre tantos trusses tomo sea posible. /<:+ �'F)=;:c• LATERAL RESTRAINT Bracing �a•:i�f` d Web Members L.• ii Position loads over load bearing walls. it;s &DIAGONAL BRACING .�' \�( Coloque las cargos sobre las paredes soportantes. f ARE VERY IMPORTANT -\� Truss bracing not ` \.� ALTERATIONS—ALTERACIONES shown for clarity. LLA RESTRICCI®N `' `�-• I Refer to BCSI-B5 Summary Sheet-Truss Damage Jobsite Modifications&Installation Errors. LATERAL Y EL y Vea el resumen BCSI-B5 Dafios de trusses Modificaciones en to Obra Emotes de Instalad6n ARRIOSTRE Do not cut,alter,or drill any structural member of a truss unless DIAGONAL ® specifically permitted b the Truss Design Drawing. SON MUY � �` Bottom Chords Y 9 t No torte,allele o perfore ningun miembro estructural de los IMPORTANTEST Diagonal Braces every 10 trusses,a menos que este especificamente permiticio en el dibujo ------ ® truss spaces(20'max.) del dise"no del truss. 9 10'-15'max.Same spacing as bottom chord Lateral Restraint Some chord and web members Trusses that have been overloaded during construction altered without the Truss Manufacturers ! prior approval may render the Truss Manufacturers limited warranty null and void. not shown for clarity. 3)BOTTOM CHORD—CUERDA INFERIOR Trusses que se han sobrecargado durdnte to construcd6n o han sido alterados sin Una autorizaci6n previa del Fabricante de Trusses,pueden reducir o eliminar la garantia del Fabricante de Trusses. Lateral Restraints-2x4x12'Of NOTE:The Truss Manufacturer and Tnum ss Designer rely on the presumption that the Contractor and crane operator(B applicable)are ' `-� .` `'I professionals with the capability to undertake the work they have agreed to do on any given project.If the Contractor believes it needs greater lapped over two trusses. �\ ��-�\ assls ed in to some aspect m the construction project,a should seek assistance from a competed party.The methods in and procedures �� �� -���• outlined In this document are Intended to ensure that the overall construction techniques employed will put the trusses into place SAFELY. These remmmendatons for handling,installing,restraining and bracing trusses are based upon the collective experience or leading Bottom \�_ - �� ���,' personnel imrolved with truss design,manufacture and installation,but must,due to the nature of respon4bilities involved,be presented chords \� `\ \\` only as a(VIDE for use by a qualified Building Designer or Contractor.Itis not intended that these recommend ons be interpreted as _ superior to the Building Designer's design specification for handling,installing,restraining and bracing trusses and it does not preclude the `\\ 1"� �`•`� ' use of other equivalent methods for resNelning/bacing and providing stability for the walls,columns,gears,roofs and all the Interrelated 7 structural building components as determined by the Contractor.Thus,WTCA and TPI expressly disclaim any responsibility for damages arising from the use,application,or reliance on the recommendations and information contained herein. Diagonal Braces every PU ER Y' 10 truss spaces(20'max.) In 1. TRUSS PLATE INSTITUTE 10'-15' Some chord and web members 6300 Enterprise lane•Madison,wt 53719 218 N.Lee St,Ste.312•Alexandira,VA 22314 608/2744849•www.stxindustry.com 703/683-1010•www.tpinstorg max. not shown for clarity. { - BIWARNllx17 20061115 WU IN .. 1 AM.r, iEN 060Few. -P MORON '■' . .. ._ - . _ STEPDOWN HIP CORNER SET DETAIL HIP GIRDER (3) 16d (0.162"x3.5") TOE-NAILS (2) 16d (0.162"x3.5") TOE-NAILS NOTE: CJ5 10d (0.146"x3.0) GUN NAILS MAY BE SUBSTITUTED r N IN PLACE OF 16d TOE—NAILS UP TO THE MAXIMUM N v �) REACTIONS SHOWN BELOW. 0 _I CJ3 JP (2) NAILS: R=260# U=345# w �\ Q (3) NAILS: R=390# U=520# 0 z o CJ1 �z W 0 n LO oe W CORNER JACKS WEBS VARY Li- 2'2'-0' -0e 2'-0" 2'-0" 2'-0" _ �k NOTES: ` CJ1 CJ3 CJ5 1. DESIGN BASED ON SOUTHERN PINE LUMBER. HIP JACK 2. TRUSS TO BEARING CONNECTION BY OTHERS. TRUSS PLATES AND LUMBER AS SHOWN, OR PER w 3. WIND LOADING BASED ON ASCE 7-10 MEAN INDIVIDUAL TRUSS DESIGNS. 0 ROOF HEIGHT 30', EXP C ENCLOSED, RISK 0 CATAGORY II a_ 4. APPLICATION OF TOENAILS PER NDS-2005 ** END JACK "IfARRlRG"READ AAD F'OLLOIf eLt RDL�09 t� TC LL 20-30 PSF REF 17usaea segalre eilretaa care In febrloattos,hendRn�,ablppin`,lnatellbu and breolna. Rater to end follow >l�(DnDdlnp Componeat tlafety 'a' 4701=41-211 loa by 1Pl end*1-211 for safety preoticea ptlor to performfnR TC DL 7-20 PSF DATE 3/21/12 these t�motloaa. InataDen ahaII petnlde temporary breoln�Der'HIS. Unlea.aotad othmwLe,top chord aMD Dsn p ettmhed attaattaal peaeL end bottmn chord sball have a properly ettnohed d m a a .�s thts�p�.mi a Pre.t+ tnt >�mn�b"emII mwued Per`''ms BC DL — PSF DRWG STEPDOWN HIP "nG=T Nr" yO11=COPY OF 1619 DffiIOR TO DWALLAt10R CORS WTM. lrlr 9etidwt campea�to Oinap Ica(II1fDC0).ha�not ba r. sidle for an davletlon tram tht,da BC LL 10.00 PSF b�d of Dram. �"I=roon eeote plat" made of or itet'°a(<mv/1 MesnimAM undo ;/n�o/aO TOT. LD. 37-55 PSF Ajp PLtae mob feoe of tnvr.Podtloaed a.chows above and on hint DetafL. A Gael en Lida daewhu or Dore:palndloatea eeoeptaaoe and taolnat�el eaatneerta=raapoaatldl!!y solely for the train comp®en!dadQa ab.'. The ralt.un"y cad we o!thL oompoaml.[or any bufldfo�L the rerponidbility e!the Bo1Wfa��East=er par Ax9r/�fpf t sea.a DUR. FAC. 1.25 Ply HCO wwwwdtwbod.oem; www.tpiaat.00m;Y'IYA www.abofndaatry Dom;1CC:wwwlooaafe.ord SPACING 2-0-0 Valley Detail - ASCE 7-101 180 mph, 30' Mean Height, Partially Enclosed, Exp. C, Kzt=1.00 Top Chord 2x4 SP #2N, SPF #1/#2, DF-L #2 or better, Unless specified on engineer's seated design, apply 1x4 'T' brace, 80% Bot Chord 2x4 SP #2N or SPF #1/#2 or better, length of web, sane species and SRB grade or better, attached Webs 2x4 SP #3, SPF #1/#2, DF-L #2 or better, with 8d box (0,113' x 2,5') nails at 6' o,c„ or continuous lateral bracing, equally spaced, for vertical valley webs greater than 7'-9', Attach each vane to ever supporting truss wlthl For verticals over 10'-0' tall, apply (2) 1x4 'T' braces, 807 length of y y pP web, same species and SRB grade or better, attached with 8d box 560# connection or with (1) ITWBCG HA4 (0.113' x 2.5') nails @ 6' oz, or HA2,5 connector or equivalent for Top chord of truss beneath valley set must be braced with) ASCE 7-10 180 mph, 30' Mean Height, Part, Enc, property attached, rated sheathing applied prior to valley truss Building, Exp, C, Wind TC DL=5 psf, Kzt = 1.00 Or Installation. ❑r ASCE 7-10 160 mph, 30' Mean Height, Part, Enc. = 1,00 Purlins at 24' o,c, or as otherwise specified on Engineer's sealed design, Building, Exp, D, Wind TC DL=5 psf, Kzt Or By valley trusses used In lieu of purlln spacing as specified on Engineer's sealed design. Cut from 2x6 or Larger as req'd � xxx Note that the purlln spacing for bracing the top chord of the truss 4-0-0 beneath the valley Is measured along the slope of the top chord, 12 ���W2 ++ Larger spans may be bulli as long as the vertical height does 12 Max, ' not exceed 14'-0'. W2X4 X4 Bottom chord may be square or pitched cut as shown, ,----- 8-0-0 W2X4 W4X4 12 Valle 12 Max. I 4X Spacing WIX3 6-0-0 WIX3 Pitched Cut Square Cut Stubbed Valley Optional Hip (Max S acln > W2X4 Bottom Chord Bottom Chord End Detail Joint Detail WlX3 WSX3 Valley Valley 16-0-0 W1X3 ** f o m n T u e 12 t 2 o,(--. 4; WlX3 4X4 W1X3 ll S t 114a 4 6-0-0 Q`1 ���3 W X4/SPL (Max Spacing> WIX3 W2X4 , Common T asses Partlai Framing at 21, o.c, Plan 20-0-0 (++) Supporting trusses at 24' o,c, maximum spacing, ■WARNINGise READ AND r2LOV ALL NOTES EPI THIS DRAVDiGI TC LL 30 30 40PSF REF VALLEY DETAIL eeINPORTANTse FURNISH THIS DRAVING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. Trusses requMe extreme care to fabricating,handift,shipp{Gn�,pp,imstalttn and bracing} Refer to and TC DL 20 15 7 PSF DATE 2/16/12 follow the latest edition of SCSI®u"d Component Safety Infornation,by TP1 and VTCA'for oft fety ppracticts prhr to perfarmkap theca functions. Instniters shall provide temparorY bracwp par BCSL Unless noted othentse,tap c»ora shxitl have property ottacfied structural sheathing and bottom BC DL 10 10 10 PSF DRWG VAL1801 0 chord sinll have n pproperly attached r{pk!ceNing Loeatbrfs shown for permanent laternl restraint of webs sfintt haw brnetrg hstattad per HCSI sertbns H3,HT Vim as nppticnble. Apply ptatea to BC LL 0 0 0 PSF each face U,truss and poaklon ns shorn above and on the hint Detalis,unless noted oiherrlse. Building Components Group Inc. Refer to dra.4.16GA-2 for atnrdard plate posltlons. TOT, LD, 60 55 57PSF ITV Melfi Components Group Inc shall not be responsible for any deviation from this drawing,any falurs to build the truss in conformanea with ANSI/TPI 1,or for harAing,shfppinp,InstnOotlon 0 bracft of trusses. A seat on this drawing or cover page tktbv this drawing,InMcates accept an w of professlaml onelneerhp responslbillty solely for the design shown The sultabAlty and use of this DUR,FAC.1.25/1.33 1,15 1,15 drawing for arty structure is the respons6Aity of the Building Designer per ANSI/TPI I See& Earth City,M063046 For more imfornntlon see this�'s(general notes page and these web eltaS, SPACING 24,0' ITVHCG+wwv,ltwbcl}no")TPli vw,pinst,orgl VTCAi www.sbcWlustry.orgi IM www,kcsafe.org t • e r' # = Bul" 1di-AgOdmpon 933 hem Pine(9.55 Spectffc&avi y) HAlU', -DaURS10[.._ -.EPi!�$tHSi�=:. ALUKUMDOWMARDLUDS AUDWLEUPWOLUR PfiDP mr, smoffm Pmbodf 3 - JOIST JOIST HE$gEA; . dfltST .:.,tw-_ UE�1li1t l iECT1}R i�AD li1RAT 1�1C 08- com 1iMf-R O{UGE WIDTH REGIff DEPTH- - - 4I7 Sii!E� QPf .. . : . _• i.•: �.�. a�5 s :: ..- .- : :!:i..a.... 1?5 -1.6 AIAM 1112 18 19!16 5112 2 3/4 0.148'x1.5' 8 0.16254.5' 24 3350 3350 3350 3350 1025 1175 1280 130; AHU28 1112 18 19/16 6112 2314 0.148'x1.5' 12 - 0.162'703.5' 24 1 3655 4095 4250 4375 1535 1765 1915 209 AHU210 1.1/2 18 19116 81/2 2314 I 0.148'x1.5' 16 0.162'x3.5' 24 3655 4200 4565 5605 2045 235D 2555 3271 AHU26-2 3 18 37/16 51/2 2314 0.148"x3.0" 8 0.162'x3.5" 24 3350 335D 3350 3350 1025 1175 1280 130 AH028-2 3 '18 37/16 51/2 2314 0.14B-.,C.Q' 8 0.162-Y3.5' 24 3655 4200 4375 4375 1535 1765 1915 2-W AH0210-2 3 18 37/16 5112 2314 0.148'x3.0' 8 0.162'x3.5' 24 3655 4200 4565 5845 2645 2350 2555 3271 AHU46 3112 [la 18 39116 5112 23/4 (.148 x3.0' 8 0.16253.5' 24 3350 33150 3350 3350 1025 1175 1280 130 AHU48 311218 39116 5112 2314 0.148'x3.0' 8 416254.5' 24 3655 4200 4375 4375 1535 1765 1915 209 AHU410' 31/2 39116 51/2 233(4 1,414854.0' 8 0.162545' 24 3655 4200 4555 5845 2045 2350 2555 3271 SoOthem Pine(0.55 Speciac GravKj) HANGER DIMENSION COMMON HAI-Tv.PE FAMIEf1S 14MYVABLEBMWARDLMM ALLOWABLE UPWARD LOADS PRODUCT SUPPORTED PRODUCT CLEAR OVERALL OVERALL JOIST FEUER LOAD DURATION FACTOR LOAD DURATION FACTOR CODE MEMBER GAUGE WIDTH HEIGHT DEPTH (m� (m) (e) SIZE QTY SIZE QTY 1 1.15 1.25 1.6 1 1.15 125 1.6 AGUS26 11/2 i2 1518 57115 4114 Q.1485ct_5- 24 0.762"x3.5' 30 4975 5035 5035 5035 2749 2700 270D 2700 AGUS28 11/2 12 1 518 615/16 4114 0.148'X1.5' 30 0.162't3.S- 40 6555 7410 7410 7410 3485 3485 3485 3485 ASUS210 1112 12 1 518 815716 41/4 6.1485x1.5° 38 0.162'x3.5' 50 8210 8865 8865 8865 5035 5035 5035 5035 AGUS212 11/2 12 1 518 10 15116 4114 0.148x1.5' 46 0.162"x3.5" 60 9240 9240 9240 9240 64S:•S 6475 6475 6475 AGUS26-2 ;3 12 31/8 57116 41M 0.148'x3.0' 24 4162'35` 30 4925 5035 5035 5035 2700 2700 2700 2700 AGIIS20-2 3 12 3118 615/16 4114 0.1485Ci_0' 30 0.162'"..3.5' 40 6565 7410 7410 7410 3485 3485 3485 3485 AGUS210-2 3 12 31/8 815116 41/4 4148'x3.0' 38 4162545" 50 8210 8865 8865 8865 5035 5035 5035 5035 AGU5212 2 3 12 31/8 1015/16 44114 414854.0' 46 0.16253.5' 60 9240 9240 9240 9240 64555 6475 6475 647; AGUS26-2T -3 12 37116 57116 4114 4148'X31?' 24 0-162a5'- 30 4925 503.5 5035 50-35 2700 2700 2700 2700 . ' AGUS28 2T3 12 3 7116 615116 4114 0.14854.0` 30 0-_#62 .5' 40 6565 7410 7410- 7410 3485 3485 3485 3485 AGUSMU-2T 3 12 37116 815116 4114 0.14854.0' 38 0.162'3.5" 50 8210 8865 8865 8865 5035 5D35 5035 5035 AGUS212-2T 3 12 1 37116 1015/16 4114 0.14854.0' 46 4162'x3.5' 60 9240 9240 9240 9240 6455 1 6475 6475 6475 AGUS46 3112 12 35/8 5 7176 41/4 4148X3.0` 24 0.16254.5" 30 4925 5035 5D35 5035 2700. 2700 2709 2700 AGUS48 3112 12 3 5/8 615116 4114 0.148X3.0" 30 4162545' 40 6565 7410 741D 7410 3485 3485 3485 3485 AGUS410 3112 12 3 518 815/16 4114 41485.0' 38 416253.5' SD 8210 8865 8865 8855 5035 5035 5935 5035 AGUS412 31/2 12 3 518 1015/16 4114 0.14854.0" ,46 0.162"x33.5" 60 9240 9240 9240 9240 6455 6475 6475 6475 AGUS26-3 4112 12 4 518 57/16 4114 4148x3.0' 24 0.16254.5' 30 4925 5035 5035 5033 2700 2700 2700 27UU AGUS28-3 41/2 12 1 45/8 61S116 4114 0.14854.0" 30 0.162'x3.5' 40 6565 7410 7410 7410 3485 3485 -3485 13495 AGUS210-3 4112 12 45/8 815116 4114 0.148'x3.0' 38 0.16253.5' 50 8210 8865 8865 8855 5035 5(35 5035 5035 AGUS212-3 4112 12 45/8 1015116 4114 0.148'x3.0' 46 0.16254.5" 60 9240 9240 9240 9240 6455 6475 6475 6475 AGUS26-3T 4112 12 5 57116 4114 0.148'x3.0' 24 0_162'x3.5' 30 4925 5035 M35 5035 2700 2700 2700 2700 AGUS28-3T 41/2 12 5 675/16 41/4 0.148'x3.0" 30 0:16254.5' 40 6555 7410 7410 1 7410 3485 3485 3485 3485 AGUS21G-3T 41/2 12- 5 815116 . 41/4 41485:3-o, 38 0.762'53.5' 50 8210 805 8865 8865 5035 5035 5035 5035 AGUS212--3T 4112 12 5 1 101-✓16 F 41/4 414854.0' 46 0.162'x35' 60 9240 19240 9240 9240 6455 1 6475 1 6475 1 6475 21. ✓ ! ° �••� 1 #0d Ccrosncn Wis am 0-146'x a z 168 Common Nags a:e 0-162 x EVALUAMON OR • .r 3'Iv[ v -1�?�'-�J's tYtf.Tts§it�s'fY rLARDI1?L u s <2413' is 4. AGUS 28-]T p-REP PORED iOR AHU26 1` �C j4G 1 S L1O'+ _ �• <�.i 1 J ' I I y� �5� klrte, �3._�dE•.I'a;=a;=C;:s� �:�:% PG Buffi•..i ig v2iEeEC-.�Z3nsf-Tis r`F-amp c'•. . e Die1St �s .�_ ¢� ra .�das it o�Vis-aiaa i-�ar y�� S'S?Ta 77f€ m'3Ude !ents S aha i;0148 Buffi'kagg;Code and foi29?3'er-3 [:i ampfiarce-.�s1e