HomeMy WebLinkAboutProduct Approval 4 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization 119503 �TRINITYJ - 353 CHRISTIAN STREET,UNIT#13 ERD, OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT GAF Evaluation Report 01506.04.08-1112 1Campus Drive FL10626-R12 Parsippany,N1 07054 Date of Issuance:04/25/2008 Revision 12:03/31/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: GAF Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,�then it shall be done in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: t� w - The facsimile seal appearing was authorized by Robert Nieminen, Robert J.M.Nieminen,P.E. '0T' �0rjr��' P.E. n03/31/2015.This signed ,y fis, ..,;..,, v g Florida Registration No.59166,Florida DCA ANE1983 t:,., /p4at -,5•. document.signed,sealed hardcopies have been transmitted to the �, Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. T TTRINITYIERD, ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: GAF Roof Underlayments, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. 'Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2004 1507.2.4,1507.2.9.2,1507.5.3, Physical Properties ASTM D1970 2009 1507.7.3 1507.2.3 Physical Properties ASTM D6757 2007 1507.11.2 Physical Properties ASTM D6164 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012 3. REFERENCES: Entity Examination Reference Date ERD(TST 6049) Physical Properties G12210.06.09 08/03/2009 ERD(TST 6049) Physical Properties G34150.08.11 11/14/2011 ERD(TST 6049) Physical Properties G40630.01.14-2B 01/07/2014 ERD(TST 6049) Physical Properties G46160SC 04/14/2014 PRI(TST 5878) Physical properties GAF-026-02-01 03/26/2002 PRI(TST 5878) Physical properties GAF-027-02-01 03/26/2002 PRI(TST 5878) Physical properties GAF-042-02-02 03/12/2004 PRI(TST 5878) Physical properties GAF-042-02-01 06/03/2005 PRI(TST 5878) Physical properties GAF-154-02-01 02/06/2007 PRI(TST 5878) Physical properties RGM-023-02-01 02/09/2007 PRI(TST5878) Physical properties ELK-311-02-01 09/11/2007 PRI(TST 5878) Physical properties GAF-238-02-01 03/03/2010 PRI(TST 5878) Physical properties GAF-275-02-01 11/11/2010 PRI(TST 5878) Physical properties GAF-349-02-01 06/19/2012 PRI(TST 5878) Wind Uplift GAF-434-02-01 09/16/2013 PRI(TST 5878) Wind Uplift GAF-434-02-03 09/16/2013 PRI(TST 5878) Wind Uplift GAF-434-02-04 09/16/2013 ITS(TST 1509) Physical properties 3077464-002 09/14/2005 ITS(TST 1509) Physical properties 3077464-02 01/09/2006 UL(TST 1740) Physical properties 02NK22569 06/04/2002 UL(TST 1740) Physical properties 10NK11990 05/18/2011 Miami-Dade(CER 1592) HVHZ compliance 13-1104.05 02/20/2014 Miami-Dade(CER 1592) HVHZ compliance 13-1104.11 03/06/2014 Miami-Dade(CER 1592) HVHZ compliance 14-1022.26 02/05/2015 ICC-ES(EVL2396) IBC compliance ESR-1322 01/01/2014 UL,LLC.(QUA 9625) Quality Control Inspect,File R10689,Stockton,CA 11/12/2014 UL,LLC.(QUA 9625) Quality Control Inspect,File R10689,Hickory,NC 03/04/2015 UL,LLC.(QUA 9625) Quality Control Inspect,File R10689,Mt.Vernon,IN 01/16/2015 UL,LLC.(QUA 9625) Quality Control Inspect,File R10689,Pryor,OK 02/05/2015 4. PRODUCT DESCRIPTION: 4.1 Self-Adhering Underlayments: 4.1.1 Liberty-SBS Self-Adhering Base/Ply Sheet is a smooth-surfaced,fiberglass-reinforced,self-adhering SBS modified bitumen roof underlayment. 4.1.2 StormGuard®Film Surfaced Leak Barrier is a film-surfaced,fiberglass-reinforced,self-adhering SBS modified bitumen roof underlayment. StormGuard® Film Surfaced Leak Barrier is also used as a secondary water barrier to seal roof decks. Exterior Research and Design,U.C. Evaluation Report 01506.04.08-1132 Certillcate of Authorization#9503 F1.30626-1132 Revision 12:03/31/2015 Page 2 of 8 TRINITY I ERD 4.1.3 UnderRoof l 2 Polyester-Surfaced Leak Barrier is a spun-band-glass-reinforced-polyester-mat-surfaced,composite- reinforced,SBS self-adhering modified bitumen roof underlayment. 4.1.4 UnderRoof-HT High Temperature Leak Barrier is a polyester-mat-surfaced,fiberglass-reinforced,self-adhering SBS modified bitumen roof underlayment. 4.1.5 WeatherWatch® Mineral Surfaced Leak Barrier is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS modified bitumen roof underlayment. WeatherWatch® Mineral Surfaced Leak Barrier is also used as a secondary water barrier to seal roof decks. 4.1.6 WeatherWatch® XT Mat Surfaced Leak Barrier is a coated-mat-surfaced, fiberglass-reinforced, self-adhering SBS modified bitumen roof underlayment. 4.2 Mechanically Fastened Underlayments: 4.2.1 VersaShield®Fire-Resistant Roof Deck Protection is a non-asphaltic,fiberglass-based roof underlayment and/or fire barrier. . 4.3 Asphalt-Applied Underlayments: 4.3.1 Ruberoid® Mop Granule is a granule-surfaced, polyester-reinforced, asphalt-applied SBS modified bitumen roof underlayment. 4.3.2 Ruberoid® Mop Granule FR (formerly Ruberoid°Mop 170 FR) is a granule-surfaced, polyester-reinforced, asphalt- applied SBS modified bitumen roof underlayment. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert-Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory or test report from accredited testing agency for fire ratings of this product. 5.4 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop GAF Roof Underlayments are follows: TABLE 1:ROOF COVER OPTIONS Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes& Slate or Shingles Shingles Simulated Slate VersaShield°Fire-Resistant yes No No No No No Roof Deck Protection Liberty-SBSSelf-Adhering Yes No No No No No Base/Ply Sheet StormGuard®Film Surfaced Yes No No Yes No No Leak Barrier UnderRoof'"2 Polyester- Yes Yes Yes No No Yes Surfaced Leak Barrier See 5.5.1 UnderRoof'HT High Yes No No Yes No No Temperature Leak Barrier WeatherWatch®Mineral Yes No No No No No Surfaced Leak Barrier WeatherWatch®XT Mat Surfaced Leak Barrier Yes No No No No No Ruberoid®Mop Granule Yes Yes Yes No Yes Yes See 5.5.1 Yes Ruberoid®Mop Granule FR Yes Yes See 5.5.1 No Yes Yes Exterior Research and Design,LLC. Evaluation Report 01506.04.08-R12 Certificate of Authorization#9503 FL10626-R12 Revision 12:03/31/2015 Page 3 of 8 r Q0TR1N1W_JERb 5.5.1 "Foam-On Tile"is limited to use of the following unless tensile adhesion/long term aging data from an accredited testing laboratory is provided. Underlayment(s) Adhesive Option(s) UnderRoofTM'2 Polyester-Surfaced Leak Barrier 3M-2-Component Roof Tile Adhesive AH-160(FL6332) Ruberoid®Mop Granule;Ruberoid®Mop Granule FR Dow TileBond(FL717) 5.6 Allowable substrates are noted below: 5.6.1 Liberty'"' SBS Self Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; UnderRoof- 2 Polyester- Surfaced Leak Barrier; UnderRoof' HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced Leak Barrier and WeatherWatch®XT Mat Surfaced Leak Barrier.Self-Adhered to Deck: ➢ New untreated plywood; ➢ Existing untreated ASTM D41 primed plywood. Ruberoid®Mop Granule and Ruberoid®Mop Granule FR.Asphalt-Applied to Deck: ➢ ASTM D41 primed structural concrete. 5.6.2 Liberty- SBS Self-Adhering Base/Ply Sheet StormGuard" Film Surfaced Leak Barrier; UnderRoof- 2 Polyester- Surfaced Leak Barrier; UnderRoof- HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced Leak Barrier and WeatherWatch® XT Mat Surfaced Leak Barrier Self-Adhered to Mechanically Attached Base Underlavment: ➢ ASTM D226,Type II felt. ➢ StormSafe-Anchor Sheet Ruberoid® Mop Granule and Ruberoid® Mop Granule FR Asphalt-Applied to Mechanically Attached Base Underlavment: ➢ GAFGLAS®#80 Ultima-Base Sheet; ➢ Ruberoid®20 Smooth. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum . requirements of FRSA/TRI April 2012(04-12)or as detailed below. 5.6.3 Bond to Other Substrate Types: ➢ ASTM D41 primed metal(flashing metal,valley metal,etc.) 5.6.4 Wind Resistance for Underlavment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 5.6.4.1 Maximum Design Pressure=-45 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional)ASTM D41 Underlayment: UnderRoofTM'2 Polyester-Surfaced Leak Barrier,self-adhered 5.6.4.2 Maximum Design Pressure=-45 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: GAFGLAS®#80 Ultima'"'Base Sheet or Ruberoid®20 Smooth mechanically attached with 12 ga.,min. 1.25-inch long ring shank nails through 32 ga.,1-5/8 inch diameter tin caps spaced 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at two(2),equally spaced,staggered center in the field of the sheet. Top Layer: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 lbs/square. Exterior Research and Design,LLC. Evaluation Report 01506.04.08-1112 Certificate of Authorization#9503 F1.30626-1112 Revision 12:03/31/2015 Page 4 of 8 R 1 Q0TmN1WJERb, 5.6.4.3 Maximum Design Pressure=-45 psf. ' Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: GAFGLAS®#80 Ultima'"'Base Sheet or Ruberoid®20 Smooth mechanically attached with 12 ga.,min. 1.25-inch long ring shank nails through 32 ga.,1-5/8 inch diameter tin caps spaced 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3),equally spaced,staggered center in the field of the sheet. Top Layer: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 lbs/square. 5.7 Exposure Limitations: 5.7.1 Liberty- SBS Self-Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; UnderRoof- HT High Temperature Leak Barrier;WeatherWatch®Mineral Surfaced Leak Barrier and WeatherWatch®XT Mat Surfaced Leak Barrier shall not be left exposed for longer than 30-days after installation. 5.7.2 VersaShield® Fire-Resistant Roof Deck Protection, UnderRoof- 2 Polyester-Surfaced Leak Barrier, Ruberoid® Mop Granule and Ruberoid®Mop Granule FR shall not be left exposed for longer than 180-days after installation. 6. INSTALLATION: 6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Install self-adhering underlayments when ambient temperatures are minimum 45°F and rising. 6.4 All metal surfaces shall be primed with Matrix`""307 Premium Asphalt Primer or alternate GAF accepted ASTM D41 primer prior to application of self-adhering membranes. 6.5 VersaShield®Fire-Resistant Roof Deck Protection: 6.5.1 Install VersaShield® Fire-Resistant Roof Deck Protection in compliance with manufacturer's published installation instructions and the requirements for ASTM D6757 underlayment in FBC Section 1507.2.3 for the type of prepared roof covering to be installed. A double layer is required for 2:12<roof slope<4:12. No hammer tacks or staples are permitted 6.5.2 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty— SBS Self-Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; UnderRoofl 2 Polyester-Surfaced Leak Barrier; UnderRoof- HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced or WeatherWatch® XT Mat Surfaced Leak Barrier at vulnerable leak areas, including but.not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At other areas,install the leak barrier over the underlayment. 6.6 Libertv-SBS Self-Adhering Base/Ply Sheet: 6.6.1 Install Liberty— SBS Self-Adhering Base/Ply Sheet in compliance with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.6.2 The minimum and maximum roof slopes are''/z:12 and 6:12,respectively. Back-nailing is required when slope is 1:12 or greater. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 18"o.c.within 3-inch side laps. 6.6.3 For non-tile applications,direct to deck: For direct-bond to deck applications plywood shall be primed with Matrix—307 Premium Asphalt Primer or alternate GAF accepted ASTM D41 primer at''/:to%gallon per square. Prior to removal of release film,align sheets properly starting at the low-point of the roof(eave)with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes.Roll out sheet and allow to'relax'for min.30 minutes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of Matrix-201 Premium SBS Flashing Cement over drip edge. Exterior Research and Design,LLC. Evaluation Report 01506.04.08-1132 [ertiJlcate of Authorization#9503 FL10626-1112 Revision 12:03/31/2015 Page 5 of 8 TRINITY(ERO Continue upslope in a similar manner,maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Ensure all end laps are staggered at least 18-inch apart. Use a weighted lawn or linoleum roller to ensure complete adhesion to the substrate. Use a hand roller to firmly bond side and end laps. 6.6.4 For non-tile applications to mechanically attached anchor sheet: Install ASTM D226,Type II felt in accordance with codified requirements or StormSafe'"Anchor Sheet in accordance with Section 6.6. Install Liberty'""SBS Self-Adhering Base/Ply Sheet over the mechanically attached anchor sheet as noted above. 6.7 StormGuard®Film Surfaced Leak Barrier: 6.7.1 Install StormGuard®Film Surfaced Leak Barrier in compliance with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.7.2 Back-nailing is required. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c. within 3-inch side laps. 6.7.3 For non-tile applications,direct to deck: Prior to removal of release film,align sheets properly starting at the low-point of the roof(eave)with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of Matrix-201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner,maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Ensure all end laps are staggered at least 18-inch apart. Use a hand roller to firmly bond side and end laps. 6.7.4 For non-tile applications to mechanically attached anchor sheet: Install ASTM D226,Type II felt in accordance with codified requirements or StormSafe-Anchor Sheet in accordance with Section 6.6. Install StormGuard®Film Surfaced Leak Barrier over the mechanically attached anchor sheet as noted above. 6.8 UnderRoof-2 Polyester-Surfaced Leak Barrier: 6.8.1 Install UnderRoof"" 2 Polyester-Surfaced Leak Barrier in compliance with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.8.2 The minimum and maximum roof slopes are 2:12 and 12:12,respectively. Back-nailing is required when slope is 4:12 or greater. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 12"o.c.within 4-inch side laps. 6.8.3 For tile roof installations: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted herein as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 6.8.4 For non-tile applications,direct to deck: Prior to removal of release film,align sheets properly starting at the low-point of the roof(eave)with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of Matrix"201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner,maintaining minimum 4-inch side-laps and'minimum 6-inch end-laps. Ensure all end laps are staggered at least 3-feet apart. End laps shall be sealed with a 1/16 'to 1/8`h inch thick trowel application of Matrix-201 Premium SBS Flashing Cement. Use a hand roller to firmly bond side and end laps. Exterior Research and Design,I.I.C. Evaluation Report 01506.04.08-1112 Certificate of Authorization#9503 FL10626-1112 Revision 12:03/31/2015 Page 6 of 8 • F F w� TRINITY I ERD 6.8.5 For non-tile applications to mechanically attached anchor sheet: Install ASTM D226,Type II felt in accordance with codified requirements or StormSafe'""Anchor Sheet in accordance with Section 6.6. Install UnderRoof"'2 Polyester-Surfaced Leak Barrier over the mechanically attached anchor sheet as noted above. 6.9 UnderRoof"HT High Temperature Leak Barrier: 6.9.1 Install UnderRoof"" HT High Temperature Leak Barrier in compliance with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.9.2 The minimum and maximum roof slopes are 1:12 and 12:12,respectively. Back-nailing is required when slope is 4:12 or greater. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 12"o.c.within 4-inch side laps. 6.9.3 For non-tile applications,direct to deck: Prior to removal of release film,align sheets properly starting at the low-point of the,roof(eave)with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of TopCoat®FlexSeal'""Caulk Grade over drip edge. Continue upslope in a similar manner,maintaining minimum 4-inch side-laps and minimum 6-inch end-laps. Ensure all end laps are staggered at least 3-feet apart. Use a hand roller to firmly bond side and end laps. 6.9.4 For non-tile applications,to mechanically attached anchor sheet: Install ASTM D226,Type II felt in accordance with codified requirements or StormSafe—Anchor Sheet in accordance with Section 6.7. Install UnderRoof"HT High Temperature Leak Barrier over the mechanically attached anchor sheet as noted above. 6.10 WeatherWatch®Mineral Surfaced Leak Barrier or WeatherWatch®XT Mat Surfaced Leak Barrier: 6.10.1 Install WeatherWatch®Mineral Surfaced Leak Barrier or WeatherWatch®XT Mat Surfaced Leak Barrier in compliance with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.10.2 WeatherWatch®Mineral Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system. 6.10.3 Back-nailing is required. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c. within 4-inch side laps. 6.10.4 For non-tile applications,direct to deck: Prior to removal of release film,align sheets properly starting at the low-point of the roof(eave)with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of Matrix-201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner,maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Ensure all end laps are staggered at least 18-feet apart. Use a hand roller to firmly bond side and end laps. 6.10.5 For non-tile applications,to mechanically attached anchor sheet: Install ASTM D226,Type II felt in accordance with codified requirements or StormSafe""Anchor Sheet in accordance with Section 6.6. Install WeatherWatch" Mineral Surfaced Leak Barrier or WeatherWatch® XT Mat Surfaced Leak Barrier over the mechanically attached anchor sheet as noted.above. Exterior Research and Design,LLC. Evaluation Report 01506.04.08-1112 Certificate of Authorization#9503 FL10626-R12 Revision 12:03/31/2015 Page 7 of 8 TRINITY I ERD. 6 1 Ruberoid®Mop Granule:Ruberoid®Mop Granule FR: 6.11.1 Shall be installed in compliance with current GAF published installation requirements, subject to the limitations herein. 6.11.2 Non-Tile Applications: 6.11.2.1 Fully adhere in ASTM D312,Type IV hot-asphalt to the substrates noted in Section 5.5. Side laps shall be minimum 4- inch and end-laps minimum 6-inch wide,and offset end-laps minimum 3-feet from course to course. Side and end- laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. Consult GAF instructions regarding back-nailing requirements. 6.11.3 Tile Applications: 6.11.3.1 Refer to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein. 6.11.3.2 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the manufacturer or the named CIA entity for information on plants covered under Rule 61G20-3 CIA requirements. 9. QUALITY ASSURANCE ENTITY: U L,LLC.—QUA9625;(847)664-3281 -END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report 01506.04.08-1112 Certificate ojAuthorization#9503 FL10626-1112 Revision 12:03/31/2015 Page 8 of 8