HomeMy WebLinkAboutEnergy Code4.
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 32 Block 2 Waterstone 2265 AGR
Builder Name: ADAMS HOMES
Street: 8104 Amalfi Circle
Permit Office:
City, State, Zip: Fort Pierce , FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1994.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1378.30 ft'
b. Frame - Wood, Exterior
R=13.0 407.83 ft'
3. Number of units, if multiple family 1
c. Frame - Wood, Adjacent
R=13.0 208.00 ft'
4. Number of Bedrooms 4
d. N/A
R= ft'
10. Ceiling Types (2277.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 2277.00 ft'
6. Conditioned floor area above grade (ft') 2277
b. N/A
R= ft'
Conditioned floor area below grade (ft') 0
c. N/A
R= ft'
11. Ducts
R ft'
7. Windows(273.9 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 456.2
a. U-Factor: Dbl, U=0.33 154.00 ft'
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 66.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.55 35.56 ft'
SHGC: SHGC=0.70
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 18.33 ft'
a. Electric Heat Pump
34.6 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 5.043 ft.
Area Weighted Average SHGC: 0.292
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (2277.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ft'
b. Conservation features
b. N/A R= ft'
None
c. N/A R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.120 Total Proposed Modified Loads: 65.95
PASS
Total Baseline Loads: 71.12
I hereby certify that the plans s ications covered
e w of the plans and
"le ST,g�A'
this calculation are in comp' n the Flori gy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
r
DATE: 08-95amo Winn KPnmany
this building will be inspected for
compliance with Section 553.908
0.
*: �' • ` �,
I herebycertify that this building, as designed, is in compliance
fY 9, 9 p
Florida Statutes.
with the Florida Energy'pD;:
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
8/25/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
- PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 32 Block 2 Waterstone 22 Bedrooms: 4
User Conditioned Area: 2277
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Lot Information
Lot # 32
Block/Subdivision: Waterstone
PlatBook:
Street: 8104 Amalfi Circle
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL , 34951
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2277 20493
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2277 20493 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0
2277 ft2 ---- 0.35 0 0.65
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2547 ft2 570 ft2 Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2277 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2277 ft2 0.11 Wood
8/25/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
•
n
FORM R405-2017
INPUT 5UMMAKY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar Belo
#
Ornt
In
Wall Typew
Space
1
E
Exterior
Frame - Wood
Main
13
10
2
8
0
81.3 ft2
0
0.23
0.6
0
2
E
Exterior
Concrete Block - Int Insul
Main
4.1
38
7
10
0
385.8 ft2
0
0
0.6
0
3
N
Exterior
Frame - Wood
Main
13
4
6
10
0
45.0 ft2
0
0.23
0.6
0
4
N
Exterior
Concrete Block - Int Insul
Main
4.1
28
6
10
0
285.0 ft2
0
0
0.6
0
5
W
Exterior
Frame - Wood
Main
13
6
9
8
0
54.0 ft2
0
0.23
0.6
0
6
W
Exterior
Concrete Block - Int Insul
Main
4.1
50
3
8
0
402.0 ft2
0
0
0.6
0
7
SW
Exterior
Frame - Wood
Main
13
3
10
10
0
38.3 ft'
0
0.23
0.6
0
8
SW
Exterior
Concrete Block - Int Insul
Main
4.1
0
5
10
0 -
4.2 ft2
0
0
0.6
0
9
S
Exterior
Frame - Wood
Main
13
18
11
10
0
189.2 ft2
0
0.23
0.6
0
10
S
Exterior
Concrete Block - Int Insul
Main
4.1
37
8
8
0
301.3 ft2
0
0
0.6
0
_ 11
-
Garage
Frame - Wood
Main
13
26
0
8
0
208.0 ft2
0
0.23
0.01
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ft2
3
W
Insulated
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
V #
Ornt
Wall
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Overhang
Depth Separation
Int Shade
Screening
1
E
1
Vinyl
Low-E Double
Yes
0.55
0.7
N
17.8 ft2
23 ft 0 in
0 ft 9 in
Drapes/blinds
None
2
E
2
Vinyl
Low-E Double
Yes
0.33
0.23
N
30.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
3
N
3
Vinyl
Low-E Double
Yes
0.33
0.31
N
5.0 ft2
7 ft 8 in
0 ft 6 in
None
None
4
N
4
Vinyl
Low-E Double
Yes
0.33
0.31
N
13.3 ft2
7 ft 8 in
2 ft 10 in
None
None
5
N
4
Vinyl
Low-E Double
Yes
0.33
0.21
N
30.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
6
N
4
Vinyl
Law-E Double
Yes
0.33
0.21
N
36.0 ft2
1 ft 0 in
2 ft 10 in
Drapes/blinds
Exterior 5
7
W
6
Vinyl
Low-E Double
Yes
0.33
0.23
N
9.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
8
W
6
Vinyl
Low-E Double
Yes
0.33
0.23
N
15.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
9
SW
7
Vinyl
Low-E Double
Yes
0.33
0.23
N
12.5 ft2
11 ft 0 in
0 ft 4 in
Drapes/blinds
Exterior 5
10
S
9
Vinyl
Low-E Double
Yes
0.55
0.7
N
17.8 ft2
9 ft 4 in
0 ft 9 in
Drapes/blinds
None
11
S
9
Vinyl
Low-E Double
Yes
0.33
0.23
N
12.5 ft2
6 ft 8 in
0 ft 4 in
Drapes/blinds
Exterior 5
12
S
9
Vinyl
Low-E Double
Yes
0.33
0.23
N
30.0 ft2
9 ft 4 in
0 ft 4 in
Drapes/blinds
Exterior 5
13
S
10
Vinyl
Low-E Double
Yes
0.33
0.23
N
45.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
8/25/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
i I
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
617ft2
617ft2
64ft 9ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.0004
2390.9 131.25 246.84 .1454 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Heat Pump/
Split
Singl HSPF:8.5 34.6 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 16 35 kBtu/hr 1167 cfm 0.75 1
sys#1 ,
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft'
DUCTS
V #
---- Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
Attic 6 456.2 ft
Main
114.05 Default Leakage Main (Default) (Default)
1 1
8/25/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin Jan
Heating HJan
Feb
Feb
Mar
MarAPr
[ ] Apr
[ May
L May
[X Jun
L Jun
[X Jul
L j Jul
Au
jXjAuSeP
rj Se
Oct
Oct
Nov
Nov
H
Dec
Dec
Ventin Jan
Feb
X Mar
X
[X] A r
[ Ma
[ Jun
[ Jul
Aug
Se
[X] Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
Oft
0.3
Main
8/25/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
�2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
35.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2277
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.359
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.292
14. Heating system: Capacity
34.6
c) Area
7c.
273.9
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor: (weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
13.0
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
13.0
2. Masonry (Insulation R-value)
1062.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11 a. 30.0 b) Cross ventilation No
b) Single assembly 11 b. c) Whole house fan No
c) Knee walls/skylight walls 11 c. d) Multizone cooling credit
d) Radiant barrier installed 11 d. No e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
I
Builder Signat r� Date:
Address of New Home: 8104 Amalfi Circle City/FL Zip: Fort Pierce, FL 34951
8/25/2020 4:58:40 PM EnergyGauge@ USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1