Loading...
HomeMy WebLinkAboutEnergy Code4. FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 32 Block 2 Waterstone 2265 AGR Builder Name: ADAMS HOMES Street: 8104 Amalfi Circle Permit Office: City, State, Zip: Fort Pierce , FL, 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1994.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1378.30 ft' b. Frame - Wood, Exterior R=13.0 407.83 ft' 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=13.0 208.00 ft' 4. Number of Bedrooms 4 d. N/A R= ft' 10. Ceiling Types (2277.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2277.00 ft' 6. Conditioned floor area above grade (ft') 2277 b. N/A R= ft' Conditioned floor area below grade (ft') 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(273.9 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 456.2 a. U-Factor: Dbl, U=0.33 154.00 ft' SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 66.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.55 35.56 ft' SHGC: SHGC=0.70 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 18.33 ft' a. Electric Heat Pump 34.6 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 5.043 ft. Area Weighted Average SHGC: 0.292 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (2277.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ft' b. Conservation features b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.120 Total Proposed Modified Loads: 65.95 PASS Total Baseline Loads: 71.12 I hereby certify that the plans s ications covered e w of the plans and "le ST,g�A' this calculation are in comp' n the Flori gy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed r DATE: 08-95amo Winn KPnmany this building will be inspected for compliance with Section 553.908 0. *: �' • ` �, I herebycertify that this building, as designed, is in compliance fY 9, 9 p Florida Statutes. with the Florida Energy'pD;: OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 8/25/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT - PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 32 Block 2 Waterstone 22 Bedrooms: 4 User Conditioned Area: 2277 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Lot Information Lot # 32 Block/Subdivision: Waterstone PlatBook: Street: 8104 Amalfi Circle County: St. Lucie City, State, Zip: Fort Pierce , FL , 34951 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2277 20493 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2277 20493 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0 2277 ft2 ---- 0.35 0 0.65 ROOF # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2547 ft2 570 ft2 Medium N 0.85 N 0.85 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2277 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2277 ft2 0.11 Wood 8/25/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 • n FORM R405-2017 INPUT 5UMMAKY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo # Ornt In Wall Typew Space 1 E Exterior Frame - Wood Main 13 10 2 8 0 81.3 ft2 0 0.23 0.6 0 2 E Exterior Concrete Block - Int Insul Main 4.1 38 7 10 0 385.8 ft2 0 0 0.6 0 3 N Exterior Frame - Wood Main 13 4 6 10 0 45.0 ft2 0 0.23 0.6 0 4 N Exterior Concrete Block - Int Insul Main 4.1 28 6 10 0 285.0 ft2 0 0 0.6 0 5 W Exterior Frame - Wood Main 13 6 9 8 0 54.0 ft2 0 0.23 0.6 0 6 W Exterior Concrete Block - Int Insul Main 4.1 50 3 8 0 402.0 ft2 0 0 0.6 0 7 SW Exterior Frame - Wood Main 13 3 10 10 0 38.3 ft' 0 0.23 0.6 0 8 SW Exterior Concrete Block - Int Insul Main 4.1 0 5 10 0 - 4.2 ft2 0 0 0.6 0 9 S Exterior Frame - Wood Main 13 18 11 10 0 189.2 ft2 0 0.23 0.6 0 10 S Exterior Concrete Block - Int Insul Main 4.1 37 8 8 0 301.3 ft2 0 0 0.6 0 _ 11 - Garage Frame - Wood Main 13 26 0 8 0 208.0 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 3 W Insulated Main None .25 2 8 6 8 17.8 ft2 WINDOWS V # Ornt Wall ID Frame Panes NFRC U-Factor SHGC Imp Area Overhang Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 23 ft 0 in 0 ft 9 in Drapes/blinds None 2 E 2 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 3 N 3 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft2 7 ft 8 in 0 ft 6 in None None 4 N 4 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 7 ft 8 in 2 ft 10 in None None 5 N 4 Vinyl Low-E Double Yes 0.33 0.21 N 30.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 6 N 4 Vinyl Law-E Double Yes 0.33 0.21 N 36.0 ft2 1 ft 0 in 2 ft 10 in Drapes/blinds Exterior 5 7 W 6 Vinyl Low-E Double Yes 0.33 0.23 N 9.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 8 W 6 Vinyl Low-E Double Yes 0.33 0.23 N 15.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 9 SW 7 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft2 11 ft 0 in 0 ft 4 in Drapes/blinds Exterior 5 10 S 9 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 9 ft 4 in 0 ft 9 in Drapes/blinds None 11 S 9 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft2 6 ft 8 in 0 ft 4 in Drapes/blinds Exterior 5 12 S 9 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 9 ft 4 in 0 ft 4 in Drapes/blinds Exterior 5 13 S 10 Vinyl Low-E Double Yes 0.33 0.23 N 45.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 8/25/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 i I FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 617ft2 617ft2 64ft 9ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 2390.9 131.25 246.84 .1454 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr 1167 cfm 0.75 1 sys#1 , HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS V # ---- Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 456.2 ft Main 114.05 Default Leakage Main (Default) (Default) 1 1 8/25/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin Jan Heating HJan Feb Feb Mar MarAPr [ ] Apr [ May L May [X Jun L Jun [X Jul L j Jul Au jXjAuSeP rj Se Oct Oct Nov Nov H Dec Dec Ventin Jan Feb X Mar X [X] A r [ Ma [ Jun [ Jul Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 Oft 0.3 Main 8/25/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 �2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2277 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.359 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.292 14. Heating system: Capacity 34.6 c) Area 7c. 273.9 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor: (weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 13.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. I Builder Signat r� Date: Address of New Home: 8104 Amalfi Circle City/FL Zip: Fort Pierce, FL 34951 8/25/2020 4:58:40 PM EnergyGauge@ USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1