Loading...
HomeMy WebLinkAboutcompaction hawkins�ONN•KFA T//// .• �\CENSE •'�.. 2-� No 63;4t y 7 '.Kent, FS. E. CC Pr�ssion&RffFf�flfeer #4� Sfajej, F1odM!o?.''•GN ////'ONAL \\\\\ \ Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 Soil Nuclear Gauge Client: Project: 07-0, Report Date: 11/2/2020 Family Pools Inc 20-2365.00 Test# Test Method: ASTM D 6938 873 SW South Macedo Blvd. Family Pools Inc. 2020-2021 Master Agree Port St. Lucie Optimum Moisture I%) Port St Lucie, FL 34983 North Palm Beach, Martin, Saint Lucie, Indian... FBPE CA # 4930 In Place wet Density (pcf) Probe Depth Percent (in) Compaction FL 607 NW Community Cove 7 10/29/20 1775 - D1557 Port St. Lucie, FL 34986 N/A 11.8 107.7 Phone: 772-924-35751 Fax 772-924-3580 103.5 115.2 12 96 �ONN•KFA T//// .• �\CENSE •'�.. 2-� No 63;4t y 7 '.Kent, FS. E. CC Pr�ssion&RffFf�flfeer #4� Sfajej, F1odM!o?.''•GN ////'ONAL \\\\\ \ Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 Test Results Test# Retest Test Of Date ProctorlD Method Soil Classification Optimum Moisture I%) Maximum Dry Density (pcf) In Place Moisture (% In Place Dry Density (pc In Place wet Density (pcf) Probe Depth Percent (in) Compaction MInlMax Comp. N Remark 7 10/29/20 1775 - D1557 N/A 11.8 107.7 11.3 103.5 115.2 12 96 95/105 Pass 8 10/29/20 1775-D1557 N/A 11.8 107.7 11.4 103.4 115.2 12 96 951105 Pass 9 10/29/20 1775-D1557 N/A 11.8 107.7 11.3 103.1 114.8 12 96 951105 Pass Test Information Test # Test Location Elevation Reference Gauge Make I Model / SN / Calibrated Field Technician 7 Above Bottom of Structure: Northeast comer of Swimming Pool, 257 Bimini Dr, Ft Pierce 0-1 Troxler / T3430 136442 / Rogers, Mark 8 Above Bottom of Structure: Southeast corner of Swimming Pool, 257 Bimini Dr, Ft Pierce 0-1 Troxler / T3430 136442 / Rogers, Mark 9 Above Bottom of Structure: Southside of Swimming Pool, 257 Bimini Dr, Ft Pierce 0-1 Troxler / T3430 / 36442 / Rogers, Mark Remarks Comments Pass: Tests results comply with specifications Tests are 'Direct Transmission" (Method A) unless probe depth is noted as 'Backscaaer'. Gauge calibration data on file with the testing agency. �ONN•KFA T//// .• �\CENSE •'�.. 2-� No 63;4t y 7 '.Kent, FS. E. CC Pr�ssion&RffFf�flfeer #4� Sfajej, F1odM!o?.''•GN ////'ONAL \\\\\ \ Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1