Soil Nuclear Gauge
Client:
Project:
07-0,
Report Date: 11/2/2020
Family Pools Inc
20-2365.00
Test#
Test Method: ASTM D 6938
873 SW South Macedo Blvd.
Family Pools Inc. 2020-2021 Master Agree
Port St. Lucie
Optimum
Moisture
I%)
Port St Lucie, FL 34983
North Palm Beach, Martin, Saint Lucie, Indian...
FBPE CA # 4930
In Place
wet
Density
(pcf)
Probe
Depth Percent
(in) Compaction
FL
607 NW Community Cove
7
10/29/20
1775 - D1557
Port St. Lucie, FL 34986
N/A
11.8
107.7
Phone: 772-924-35751 Fax 772-924-3580
103.5
115.2
12 96
�ONN•KFA T////
.• �\CENSE •'�..
2-� No 63;4t y
7 '.Kent, FS. E. CC
Pr�ssion&RffFf�flfeer #4�
Sfajej, F1odM!o?.''•GN
////'ONAL \\\\\ \
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Page 1 of 1
Test Results
Test#
Retest Test
Of Date
ProctorlD
Method
Soil
Classification
Optimum
Moisture
I%)
Maximum
Dry Density
(pcf)
In Place
Moisture
(%
In Place
Dry
Density
(pc
In Place
wet
Density
(pcf)
Probe
Depth Percent
(in) Compaction
MInlMax
Comp.
N
Remark
7
10/29/20
1775 - D1557
N/A
11.8
107.7
11.3
103.5
115.2
12 96
95/105
Pass
8
10/29/20
1775-D1557
N/A
11.8
107.7
11.4
103.4
115.2
12 96
951105
Pass
9
10/29/20
1775-D1557
N/A
11.8
107.7
11.3
103.1
114.8
12 96
951105
Pass
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make I Model / SN / Calibrated
Field Technician
7
Above Bottom of Structure: Northeast comer of Swimming Pool, 257 Bimini Dr, Ft
Pierce
0-1
Troxler / T3430 136442 /
Rogers, Mark
8
Above Bottom of Structure: Southeast corner of Swimming Pool, 257 Bimini Dr, Ft
Pierce
0-1
Troxler / T3430 136442 /
Rogers, Mark
9
Above Bottom of Structure: Southside of Swimming Pool, 257 Bimini Dr, Ft Pierce
0-1
Troxler / T3430 / 36442 /
Rogers, Mark
Remarks Comments
Pass: Tests results comply with specifications Tests are 'Direct Transmission" (Method A) unless probe depth is noted as
'Backscaaer'. Gauge calibration data on file with the testing agency.
�ONN•KFA T////
.• �\CENSE •'�..
2-� No 63;4t y
7 '.Kent, FS. E. CC
Pr�ssion&RffFf�flfeer #4�
Sfajej, F1odM!o?.''•GN
////'ONAL \\\\\ \
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Page 1 of 1