HomeMy WebLinkAboutBuilding PlansNOTE: Entries to this Plan Review Record that require a field check or inspection of the installation must be coordinated with the inspection phase (R109) of the project. BUILDING PLANNING (Chapter 3) n DESIGN CRITERIA [Table R301.2011 OP /NA P d tZ9_ 4 Floor live load (Table R301.5) ON PLANS psf Y OWRoof live load (Table R301.6) ON PLANS psf�L/ OP/NA OP/NA Ground snow load NA n sf arapets an construction (R302.2.2, R302.2.3) Two-family dwelling separation (R302.3) Dwelling unit penetrations (R302.4) Dwelling/garage opening/penetration protec- tion (R302.5) ON Wind exposure category (R301.2.1.4) ✓ ON PLANE Dwelling/garage fire separation (R302.6) n High wind design criteria applicable INSPEC Under -stair protection R302.7 /,._p`o'.�v\ (R301.2.1.1) ON PLANS . P ( ) ON PLANS Seismic design category (SDC) Wall and ceiling finishes (R302.9) (Figure R301.2(2)) NA SDC C&D provisions (R301.2.2) NA Weathering ON PLANS Frost line depth NA ON PLANS Ultimate design wind speed mph OP/NA ON PLANE Flame spread index (R302.9.1) V ON PLANS Smoke -developed index (R302.9.2) INSPEC Testing (R302.9.3, R302.9.4) Termite area ON PLANS - VERY HEAVY V OP/ECALCInsulation (R302.10) / Decay area N/A ON PLANE Flame spread/smoke-developed V Winter design temperature ENERGY CALCS (R302.10.1, R302.10.2) , Ice barrier underlayment required NA INSPEC Cellulose loose -fill and exposed attic Flood hazards ON PLANS V insulation (R302.10.3, R302.10.4) FIRE-RESISTANT CONSTRUCTION (13302) INSPEC Exterior walls (R302.1, Tables R302.1(1) and R302.1(2)J OP / NA Townhouse separation (R302.2) OP / NA Continuity and structural independence (R302.2.1, R302.2.4) ROOM PLANNING REQUIREMENTS (R303 throuah R305) INSPEC Testing (R302.10.5) ON PLAN Fireblocking (R302.11) 7, ON PLANE Draftstopping (R302.12) ON PLANE Fire protection of floors (R302.13) ON PLANE Combustible insulation clearance (R302.14) Use Area (W) Width Ceiling heights Natural light` Natural ventilation" Living 70 T-0" T0" 8% floor area 4% floor area Dining 70 T-0" 7'-0" 8% floor area 4% floor area itchen N.A. N.A. T0" 8% floor area 4% floor area edroom athroom 70 N.A. 7'-0" N. - 71-0" 61-8" 8% floor area 3 square feet 4% floor area 1 V, square feet See Sections R303.1 & R303.3 for mechanical ventilation and artificial light and R303.4 for required whole -house mechanical ventilation. t 6'-8" min. at plumbing fixtures and for non -habitable basements. ON PLANERequired heating (R303.9)✓ GLAZING (13308) SANITATION (R306 and R307) ON PLANEWater closet 1 Lavatory V t/ I Tub or shower I Kitchen area with sink f I Sanitary sewer (Chapter 30) J V Private disposal (Appendix !) INSPECTC Identification (R308.1) INSPEC Louvered windows or jalousies (R308.2) INSPEC Human impact loads/hazardous locations (R308.3, R308.4) NOA/PA Skylights and sloped glazing (R308.6) -3- BUILDING PLANNING (cont'd.) GARAGES AND CARPORTS (R309) ON PLANEFloor surface noncombustible; sloped floor v (R309.1) ON PLAN Carport: open two sides; noncombustibleWx floors; sloped floor (R309.2) INSPEC Automatic garage door opener (R309.4) OP/NA Fire sprinklers (R309.5) EMERGENCY ESCAPE AND RESCUE OPENINGS (R310) ON PLANE Where required (R310..1) ON PLANEAreas, height, width, operations (R310) OP/NA Window wells (R310.2.3) ON PLANEUnder decks and porches (R310.2.4) IV[/) - ON PLANEBars, grilles, covers and screens (R310.4) n/�� MEANS OF EGRESS (R311) ON PLANEGeneral (R311.1) ON PLANEEgress door (R311..2) k/ INSPEC Landings at exterior doors (R311.3 - R311.3.3) / ON PLANEVertical egress (R311.4) N ON PLANEConstruction and attactnent (R311.5) ON PLANEHallways (R311.6) ON PLANES tairway width, headroom, .vertical' rise, walk - line (R311.7.1. - R311.7.4) ON PLAN -Stairway treads, risers profiles jx/ (R311.7.5 - R311.7.5.4) INSPEC Stairway landings and walking surfaces (R311.7.6, R311.7.7) ON PLANEHandrails required (R311.7.8) 61 ON PLAN Handrail height, continuity, grip -size /✓�� (R311.7.8.1 - R311.7.8.4) ON PLAN Stairway illumination (R303.7, R311.7.9)/ 1(4 ON PLAN -Special stairways (R311.7.10) t1f P" INSPEC Ramp slope, landings, handrails (R311.8) GUARDS AND WINDOW PROTECTION (R312) ON PLANERequired for open -sided surfaces, stairs, 'JAI ramps and landings > 30" above floor/ grade (R312.1.1) ON PLANEHeight - 36" (R312.1.2) N ON PLANEOpening limitations (R312.1.3) N` ON -PLAN-Window fall protection (R312.2) G�y,, ��i° AUTOMATIC FIRE SPRINKLER SYSTEMS (R313) OP/NA Townhouses (R313.1) OP/NA One- and two-family dwellings (R313.2) SMOKE ALARMS (R314) INSPEC Referenced standards (R314.1) ON PLANE Location and interconnection (R314.3, R314.4) ON PLANE Power source (R314.6) . V11, CARBON MONOXIDE ALARMS (R315) ON PLAN.. `New construction (R315.1, R315.2) ON PLANE Existing construction (R315.2.2) INSPEC Referenced standard (R315.6) FOAM PLASTIC (R302.8, R316) INSPEC Labeling (R316.2) ON PLANE Surface burning, thermal barrier, specify approval (R316.3 - R316.8) DECAY AND TERMITE PROTECTION (11317 and R318) ON PLANE Protection required (Table R301.2(1), R317.1, R318.1) INSPEC Quality mark (R317.2 and R318.1.1) .�-- SITE ADDRESS (R319) INSPEC Address numbers (R319.1) ACCESSIBILITY (R320) INSPEC Type B dwelling units applicable (R320.1) ELEVATORS/PLATFORM LIFTS (13321) ON PLANE Referenced'standards (R321.1 - R321.3) FLOOD -RESISTANT CONSTRUCTION (R322) ON PLANE General (R322.1�,/ ON PLANE Hazard area and requirements ' (R301.2.4, R309.3, R322.2, R32Z3) ON PLANE Design professional (R322.3.6) STORM SHELTERS (R323) ON PLANE General/referenced standard (R323.1) SOLAR ENERGY SYSTEMS (R324) ON PLAN System, installation, access (R324.2 - R324.7) MEZZANINES (13325) ON PLAN Area, egress, openness (R325.2 - R325.5) SWIMMING POOLS, SPAS AND HOT TUBS (13326) N/A ISPSC (R326.1) -4- FOUNDATIONS (Chapter 4) MATERIALS (R402) OP / NA Wood foundations (R402.1) ON PLAN Concrete, compressive strength V (R402.2, R402.3) FOOTINGS (R403) ON PLAN Soil bearing value (R401.4, R403.1) T/ ON PLAN Footing width �// (Tables R403.1(1) - R403.1(3)] ON PLAN Footing edge thickness; footing projection 2" minimum, but:_.footing thickness (R403.1.1) NA Footings in SDC and D (R403.1.2 and R403.1.6.1) ON PLAN Depth below (outside) grade = 12" minimum; V but below frost line (R403.1.4, R403.1.4.1) ON PLAN Sill plate bolting in concrete/masonry ='/2" di—y ameter bolts, within 12" but.not less than 7 bolt diameters from ends, 7" embedment (R403.1.6) INSPEC Footings adjacent to slopes (R403.1.7) NA Frost -protected shallow foundations (R403.3) ON PLAN Footings for precast concrete foundations (R403.4) FOUNDATION/RETAINING WALLS (13404 - R406)Vle, ON PLAN Masonry foundation walls (R404.1.2) ON PLAN Wall height, unbalanced backfill, nominal thickness (Tables R404.1.1(1) - R404.1.1(4), R404.1.5.1] N(m, ON PLAN Reinforcement size and spacing (Tables R404.1.1(2) = R404.1.1(4)] ON PLAN Concrete foundation walls (R404.1.3) ON PLAN Wall height, unbalanced backfill, nominal thickness (Tables R404.1.2(1) - R404.1.2(8), R404..1.5.21 ON PLAN Horizontal and vertical reinforcement size and spacing (Tables R404.1.2(1) - R404.1.2(8), R404.1.3.2, R404.1.3.3.7] ON, PLAN Stay -in -place forms (R404.1.3.3.6.1) NA SDC D provisions (R404.1.4) ON PLAN Height above finished grade (R404.1.6) V ON PLAN Sill plate size (R404.3) t/ ON PLAN Precast concrete foundation walls (R404.5) P/k ON PLAN Drains required if habitable or usable spaces are below grade` (R405) <Vk NA - Soil class (Table R405.1) ON PLAN Dampproofing if basements are below grade,14 (R406.1) ON PLAN Waterproofing if high water table` (R406.2)(t� If uninhabitable, see Under -Floor Space (R408) COLUMNS (R407) OP / NA Protection from decay or corrosion (R407.1 and R407.2) ON PLAN Structural requirements (R407.3) ON PLAN Anchorage (R407.3) V ON PLAN Wood columns (minimum 4" square) (R407.3) �I ON PLAN Steel columns, (minimum 3" diameter, Sched- ule 40 pipe) (R407.3) UNDER -FLOOR SPACE (R408) (L/'/A OP / NA Ventilation (R408.1 and R408.2) OP / NA Unvented crawl space (R408.3) OP / NA Access (R408.4) INSPEC Removal of debris (R408.5) OP / NA Finished grade (R408.6) OP / NA Flood resistance,(R408.7) -5- FLOORS (Chapter 5) WOOD JOISTS AND GIRDERS (R502) TREATED -WOOD FLOORS (ON GROUND) (R504) OP/NA. Species and grade R502.1 N/A „ 9 p g ( ) Base course: 4 thick with maximum /4 OP / NA Joists —Sleeping areas, LL = 30 psf gravel or'/2" crushed stone (R504.2.1) [Table R502.3.1(1)] N/A Moisture barrier: placed over base course OP / NA Joists—Nonsleeping areas, LL = 40 psf (R504.2.2) [Table R502.3.1(2)] N/A Materials (R504.3) OP / NA Cantilevered joists 1 STEEL FLOOR FRAMING (R505) [Tables R502.3.3(1) and R502.3.3(2)J N/A OP / NA Cold -formed steel; applicability limits; - Girder and header spans in -line framing (R505.1) [Tables R602.7(1) - R602.7(3)] N/A OP / NA Structural framing (R505.2) Joists under bearing partitions (R502.4) N/A INSPEC Material (R505.2.1) Bearing (1.5" minimum on wood or metal; 3" on masonry or concrete) and lapped joists N/A (3") (R502.6, R502.6.1) Corrosion protection (R505.2.2) N/A ON PLAN Identification (R505.2.4) Lateral restraint and bridging N/A (R502.7, R502.7.1) Fastening (R505.2.5) . INSPEC Drilling and notching (R502.8) N/A Floor construction (R505.3) ON PLAN Fastening (R502.9) V/ CONCRETE FLOORS (ON GROUND) (R506) ON PLAN Framing of openings (R502.10) !` ON PLAN Thickness: 31/2" minimum; Concrete strength ON PLAN , J'r (R506.1) Wood trusses (R502.11) ON PLAN INSPEC Support: prepared subgrade; maximum earth Draftstopping (R502.12) fill = 8'; maximum sand or gravel fill = 24" LUMBER FLOOR SHEATHING (R503.1) (R506.2.1) ON PLAN // NA Base course: 4" graded with 2" maximum Allowable span (Table R503.1) I" [ � INSPEC aggregate (R506.2.2) End joints (R503.1.1) ON PLAN Vapor retarder (R506.2.3) N, , � WOOD STRUCTURAL PANEL SHEATHING (R503.2) ON PLAN Reinforcement support (R506.2.4) INSPEC Grade (R503.2. i) EXTERIOR DECKS (R507) ON PLAN Thickness (R503.2.1)V(/- ON PLAN Support, attachment (R507.1 - R507.2.4) ON PLAN Allowable spans p ON PLAN Plastic composite materials (R507.3) [Tables R503.2.1.1(1) and R503.21. i(2)] ON PLAN ON PLAN / Decking/deck joists (R507.4, R507.5) Installation [Table 602.3(1)] ON PLAN" PARTICLEBOARD UNDERLAYMENT (R503.3) Deck beams (R507.6)ON PLAN INSPEC Deck posts, connections, footings Grade (R503.3.1) /f� (R507.7.1, R507.8) ON PLAN Thickness (R503.3.2) /l ON PLAN Installation ()]'� [Table R602.3 1 -6- WALL CONSTRUCTION (Chapter 6) WOOD CONSTRUCTION (R602) NA Material (R603.2.1) ON PLAN Construction NA Corrosion protection (R603.2.2) (Figures R602.3(1) and R602.3(2)] NA -INSPEC Identification (R603.2.4), Stud grade (R602.2) NA ON PLAN Fastening (R603.2.5) Design/construction (R602.3) ON PLAN NA Wall construction (R603.3 - R603.5) Stud spacing [R602.3.1, Table R602.3(5)] NA ON PLAN Headers (R603.6) Interior load-bearing.walls (R602.4) ✓ NA ON PLAN Studs, tracks and structural sheathing Interior•nonbearing walls: 2" x 3" at 24" o.c (R603.7.- R603.9) or 2" x 4" flat at 16" o.c. (R602.5) INSPEC A-eA,01 % SHEATHING (R604 and R605) . Drilling and notching=studs (R602.6) ON PLAN INSPEC Wood structural panels (R604) Drilling and notching —top plate (R602.6.1) ON PLAN ON PLAN Particleboard (R605) Headers (Tables R602J(1) - R6027(3) and v��/ Figure R602.7.21 MASONRY CONSTRUCTION (R606 - R610) INSPEC Rreblocking (R602.8, R30211) INSPEC Cripple walls (R602.9) OP / NA Wall bracing, lines, panels (R602.10.1, R662.10.2) OP / NA Required length of bracing, method (R602.10.3, R602.10.4, Tables R602.10.3(1) and R602.10.3(3)] OP / NA Minimum length, connections, support, joints, cripple walls (R602.10.5 - R602.10.11) OP / NA Wall anchorage (SDC C and D) (17602.11) OP / NA Simplified wall bracing (R602.12) STEEL WALL FRAMING (R603) NA General (13603.1) NA Structural framing (R603.2) ON PLAN General design (R606) NA Seismic requirements (R606.12) -ON PLAN Glass unit masonry (R607) A' (A )-e ON PLAN Exterior concrete wall, construction (R608) ON PLAN Exterior windows/doors (17609) .� OP / NA Glass unit masonry (17610) STRUCTURAL INSULATED PANEL WALYVII CONSTRUCTION (R610) ON PLAN Applicability (R610.2) ON PLAN Materials (R610.3) ON PLAN Wall panels, construction details (R610.4 - R610.10) -7- INTERIOR WALL COVERING (R702) WALL COVERING (Chapter 7) NA , Plaster material (R702.2) NA Plaster support (R702.2.3) ON PLAN Gypsum board materials (R702.3.1) L V INSPEC Gypsum board support, application and fas- tehing (R702.3.2 - R702.3.7) ON PLAN Ceramic tie (R702.4) V"' NA ON PLAN Wood shakes and shingles (� R703.6) NA Exterior plaster (R703.7) ON PLAN Stone & masonry veneer (R703.8 & Figure R703.8); Steel.angle lintels-4" minimum bearing each end (R703.8.3) ON PLAN Veneer ties: #9 U.S, gage wire or #22 Q. gage by 7/8" corrugated metal; horiiontal and vertical. spacing; 2.67'squarefeet maximum area supported (wind > 30 psf Other finishes (R702.5 and R7(2.6) and SDC C or D, maximum area = 2 +� square feet) (R703.8.4.1) ON PLAN Vapor retarders (R702.7) NG INSPEC Flashing' (R703.4 and R703.8.5) EXTERIOR WALL COVERING (R703) ON PLAN Exterior insulation and,finish systems ON PLAN Water-resistivebarrier (R703.2) (R703.9) ON PLAN ON PLAN Fiber cement siding (R703.10) A& Attachment. and minimum thickness ON PLAN [Table R703.3(1)]' Vinyl siding (R703.11) ON PLAN Wood siding (R703.5) NA Other sidings (R703.12 R703.17) ROOF -CEILING CONSTRUCTION (Chapter 8) WOOD ROOF FRAMING (R802) ON PLAN Species and grade NA Fire -retardant -treated wood (R802.1.5) ON PLAN Span ON PLAN Framing details (R802.3)d'p�F46je ON PLAN Size INSPEC Rafter ties (R802.3.1) RAFTERS [Tables R802.5.1(1) - R802.5.1(8)] INSPEC Collar ties (4' o.c., in upper third of attic) (R802.3.1) NA Ground snow load/LL = 20 psf INSPEC x 4" at 4' o.c. minimum) Purlins (2" NA Controlling design (LL or snow) (Figure R802.5.1, R802 ON PLAN ' INSPEC Ceiling not attached/ceiling.attached Bearing (R802.6) INSPEC Spacing INSPEC Cutting and notching (R802.7) INSPEC Species and grade ON PLAN Engineered wood products (R802.7.2) INSPEC Span INSPEC Lateral support and bridging (R802.8) INSPEC Size ON PLAN Framing of openings (R802.9) • INSPEC Hc/HR; Adjustment factor ON PLAN Wood trusses (R802.10) ��• b��L� , ROOF SHEATHING (13803.2) ON PLAN Roof tie -down (R802.11) INSPEC Grade CEILING JOISTS (Tables R802.4(1), R802.4(2)] ON PLAN Thickness ON PLAN Without attic storage, LL = 10psf NA FRTW allowable stresses/grading ON PLAN With attic storage LL = 20psf ON PLAN Allowable spans [Table7- -8- ROOF -CEILING CONSTRUCTION (cont'd.) STEEL ROOF FRAMING (R804) NA General (R804.1) NA Structural framing (R804.2) NA Material (R804.2.1) NA Corrosion protection (R8042.2) NA Identification (R804.2.3) NA Fastening (R804.2.5) NA Roof construction (R804.3) NA Roof tie -down (R804.3.8) ROOF VENTILATION (R806) ON PLAN Ventilation requirements (R806.1 - R806.5) ATTIC ACCESS (R807) � / -� o�Q,,,,�,,; ON PLAN Access requirements (807.1) LOC.67r(6� ROOF ASSEMBLIES (Chapter.9) ROOF CLASSIFICATION (R902) NOA / PA Roof covering materials (R902.1) WEATHER PROTECTION (R903) INSPEC Flashing (R903.2) NA Coping (R903.3) NA Roof drainage (R903.4) MATERIALS (R904) I ON PLAN Compatibility; specifications; physical charac- teristics; identification (R904.2 - R904.4) REQUIREMENTS FOR ROOF COVERINGS (R905) NOA / PA Underlayment (R905.1.1, R905.1.2) NOA / PA Asphalt shingles (R905.2) NOA / PA Clay and concrete tile (R905.3) NOA / PA Metal roof shingles (R905.4) NOA / PA Mineral -surfaced roll roofing (R905.5) NOA / PA Slate shingles (R905.6) NOA / PA Wood shingles (R905.7) NOA / PA Wood shakes (R905.8) NOA / PA guilt -up roofs (R905.9) NOA / PA Metal roof panels (R905.10) NOA / PA Modified bitumen roofing (R905.11) NOA / PA Thermoset single -ply roofing (R905.12) NOA / PA Thermoplastic single -ply roofing (R905.13) NOA / PA Sprayed polyurethane foam roofing (R905.14) NOA / PA Liquid -applied roofing (R905.15) NOA / PA Photovoltaic shingles (R905.16) ROOF INSULATION (13906) NA General (R906.1) ROOFTOP - MOUNTED PHOTOVOLTAIC SYSTEMS (R907) NA Materials and installation (R907.1 - R907.5) REROOFING (R908) NOA / PA Materials and methods (R908.1) NA Structural support (R908.2) NA Replacement/re-covering (R908.3, R908.4) ROOFTOP - MOUNTED -PHOTOVOLTAIC PANEL SYSTEMS (R909) NOA / PA Materials and installation (R909.1- R909.3) CHIMNEYS AND FIREPLACES (Chapter 10) Itj �' MASONRY FIREPLACES (R1001) ON PLAN Hearth extension (R1001.9, R1001.10) ON PLAN Construction ON PLAN Fireplace clearance (R1001.11) (Figure R1001.1 and Table R1001.1) INSPEC Fireblocking (R1001.12) NA SDC D reinforcing/anchorage (R1001.3 and R1001.4) MASONRY CHIMNEYS (R1003) ON PLAN Firebox walls and dimensions INSPEC Construction (Table R1001.1, R1003.2, (R1001.5 and R1001.6) R1003.3, and Figure R1001.1) ON PLAN Steel fireplace units (R1001.5.1) INSPEC Corbeling (R1003.5) ON PLAN Lintel (noncombustible) (R1001.7) In CHIMNEYS AND FIREPLACES (cant'd.) ON PLAN Changes in dimension (R1003.6) ON PLAN Additional load (R1003.8) ON PLAN Termination (R1003.9) ON PLAN Spark arrestors (R1003.9.2) ON PLAN Wall thickness; >_ 4" (R1003.10) ON PLAN Flue lining - material/installation _ (R1003.14 and R1003.12) ON PLAN Multiple flues (R1003.13) INSPEC Flue area (appliance) (R1003.14) ON PLAN Flue area (masonry fireplace) (R1003.15) INSPEC Inlet (R1003.16) INSPEC Cleanout opening (R1003.17) INSPEC Chimney clearance (R1003.18) INSPEC Fireblocking (R1003.19) ON PLAN Chimney crickets (R1003.20) FACTORY -BUILT FIREPLACES (131004) INSPEC Listed and labeled (R1004.1) INSPEC Installation (R1004.2 - R1004.5) FACTORY -BUILT CHIMNEYS (R1005) INSPEC Listed and labeled (R1005.1) INSPEC Installation (R1005.3 and R1005.4) EXTERIOR AIR SUPPLY (111006) INSPEC Intake size (R1006.2, R1006.4) ENERGY EFFICIENCY (Chapter 11) ENERGY, Compliance; information Electrical (N1104) (N1101.5, N1101.13) Simulated performance (N1105) CALLS Climate zone (Table N110i.7) '?�A ERI compliance -alternative (N1106) Building thermal envelope (N11W)y Existing buildings (N1107.- N1111) Systems (N1103) MECHANICAL Phapters 12-23) � Na ON PLAN Appliance labeling (M1302, M1303).;., CgSS -,NA Chimney and vent location and terminations ON PLAN Appliance access (M1305,'M1401) V (Chapters 10 and 18) .�'(� NA Special equipment (Chapter 19) INSPEC Appliance installation (101307) �°" 3 NA Boilers/water heaters (Chapter20) ON PLAN Heating and cooling equipment; load calcula- NA tions •(Chapter 14) � Hydronic piping (Chapter2l) ON PLAN `/ , f NA Special piping and storage systems Exhaust systems (Chapter 15) r (Chapter 22) ON PLAN Duct systems (Chapter 16) NA - Solar thermal energy systems (Chapter23) NA Combustion air (Chapter 17) ON PLAN Application (G2401.1) INSPEC General regulations (G2404) INSPEC Appliance location (G2406) ON PLAN Air requirements (G2407) ON PLAN Installation (G2408) NA Penetrations<of fire -resistance rated assem- blies (R302.4, R302.5) FUEL GAS (Chapter 24) r W INSPEC Clearances (G2409) INSPEC Electrical and electrical bonding (G2410, G2411) ON PLAN pipe sizing (G2413) INSPEC Piping materials (G2414) -10- FUEL GAS cont'd INSPEC Piping installation (G2415 and G2419) INSPEC Venting (G2425 - G2429) INSPEC Piping support (G2418 and G2424) NA Misc appliances INSPEC (G2423, G2430 - G2454) Valves, controls, connections (G2420, G2421 and G2422) PLUMBING (Chapters 25-33) INSPEC Water service location and depth (P2603, P2604) INSPEC Sanitary and storm sewer location and depth (P2603, P2604) INSPEC Piping support (Table P2605.1) INSPEC Listed plastic materials (P2609) ON PLAN plumbing fixtures (Chapter27) V ON PLAN Water heater size and location (Chapter 28) NA Water supply and distribution system -design and calculations (Chapter29) ON PLAN /UT Dwelling unit fire sprinkler systems (P290 ) INSPEC NFPA 13D system (P2904.1) NA Freezing protection (P2904.2.3) ON PLAN Sprinkler coverage (P2904.2.4) 4 (/ J�O INSPEC Piping materials (P2904.3) ON PLAN Flow rates (P2904.4.1, P2904.4.2) ON PLAN Water supply capacity (P2904.5.2) ON PLAN Pipe sizing (P2904.6) INSPEC Drain, waste and vent pipe sizing and riser diagram (P3004, P3005, Chapter 31) INSPEC Sumps and ejectors (P3007) NA Backwater valves (P3008) INSPEC Fixture traps (P3201) INSPEC (Chapter Storm drainage ter33 Temperature rating 9 ( P ) (P2904.2.1, P2904.2.2) INSPEC Penetrations of fire -resistance rated assem- blies (R302.4, R302.5) ELECTRICAL (Chapters 34-43) INSPEC penetrations of fire -resistance rated assem- blies (E3402.2) INSPEC Listed and labeled materials (E3403) ON PLAN Service equipment and Iocationv (E3405, E3601, E3606) ON PLAN Service size and load calculations (E3602) 1l INSPEC Available fault current (E3606) f �r�Dti,i0 ON PLAN System grounding (E3607) Q ON PLAN Required branch circuits (E370_ ("T'&r�1 ON PLAN Feeder requirements and load cai�ations (E3704) INSPEC Wiring methods (Chapter 38) ON PLAN Required lighting and receptacle outlets (E3901, E3903) INSPEC Ground -fault and arc -fault circuit -interrupter protection (E3902) INSPEC Devices and lighting fixtures (Chapter40) ON PLAN Appliance installation (Chapter4i) NA Swimming pools (Chapter42) NA Class 2 remote -control, signaling and power - limited circuits (Chapter43) MANUFACTURED HOUSING USED AS DWELLINGS (Appendix E) (-/ NA Provisions adopted (R102.5) NA Compliance with Appendix E verified -11- RIO PASSIVE RADON GAS CONTROLS (Appendix F) Provisions adopted (R102.5) NA Compliance with Appendix F verified PATIO COVERS (Appendix H) NA NA Provisions adopted (R102.5) Compliance with Appendix H verified PRIVATE SEWAGE DISPOSAL (Appendix 1) HEALTH DEPT Provisions adopted (R102.5) Compliance with Appendix I verified -EXISTING BUILDINGS AND STRUCTURES (Appendix J) NA NA Provisions adopted (R102.5) Compliance with Appendix J verified SOUND TRANSMISSION (Appendix K) NA NA Provisions adopted (R102.5) Compliance with Appendix K verified HOME DAY CARE—R-3 OCCUPANCY (Appendix M) NA NA Provisions adopted (R102.5) Compliance with Appendix M verified AUTOMATIC VEHICULAR GATES (Appendix O) NA NA Provisions adopted (R102.5) Compliance with Appendix O verified SOLAR -READY PROVISIONS (Appendix U) Provisions adopted (R102.5) NOTES - Compliance with Appendix U verified -12- , I L me me L I 1L i ________________________� TEAR ELEVATION � __ ___ _SCALE K -1'-0" 1 LEFT ELEVATION zR—u11111111111M w waw"'_a. an wmwk�l RIDGE VENTING SEE RIGHT ELEVATION cnD niknl7nicin&i 12 5t C&C Vasd Wall Wind Pressures 160 B Risk Cat. II 11<30 Ft. Zone 4 Interior Zone 5 E7derior A) 10 SF = +27.7 / -30.0 E) 10 SF = +273 37.0 B) 20 SF = +26.4 / -28.0 F) 20 SF = +26.4 / -34.0 C) 50 SF = +24.7 / -27.0 G) 50 SF = +24.7 / -31.0 D)100 SF = +23.5 / -25.0 H)100 SF = +23.5 / -28.0 E)500 SF = +20.6 / -22.0 1)500 SF = +20.6 / -22.0 Garage Door (Min. 2'-0" from corner) 7 8'x8' +24.3 / -27.5 16'x8' +23.3 / -26.0 !"'�l1Al�IYT lYrlll n�.t �..� wT FIUR ATTIC VENTING CALCULATIONS AS PER SECTION 806 IN THE FBC ztiB44 H EDITION eof7,64 PR( v uvicu mmly =wzua mow. ri. ' p 10.7 SQ.FT. VENTILATION REQUIRED PR(, 40% MINIMUM IN UPPER ROOF = 4.28 SQ. FT. ARC- RIDGE VENTING ACTUAL NET FREE AREA TO WIN OUTSIDE AIR = .139 SQ. FT./L.F. INTE 4.28/.139 = 30.79 L.F. OF RIDGE VENT REQ. Rkfil SEE ELEVATIONS FOR PLACEMENT WlN REMAINING 6.42 SQ. Fr, TO BE ACHIEVED WITH 12"x4" EXF VENT HOLES "W/ BIRD SCREENING IN SOFFIT. 11/10 EA. OPENING ACTUAL OPEN AREA TO OUTSIDE OVE AIR = .333 SQ. Fr. ROC 6.42/.333 = 19.28 REQUIRED NUMBER OF VENTS COP 20 TOTAL VENTS REQUIRED EVENLY SPACED THROUGH OUT SOFFITS RU( FLC w SHL IMP) O� n evAu ADi r rnD Dlnnr kir_nirinin ' _11!::5 I I . r I 7 i 77 i f .-. 57 ADHESIVE APPLIED DECORATIVE LOUVER 6 TEXTURED STUCCO CORBELS SCALE Y4"=1'-0" FD®H in St. Lucie Pounty Environmental Site Plan egmmyod for Cghowtion Supersedes All Pr@Vi@gg Sit@. Plans for OSTDS #51p-5E -1M7-151 & Well # Date- lklb1 '-0" TOP OF TRUSS HEEL — SMOOTH STUCCO FINISH 77 F.F.E. FRONT E' LEVT'IN m SCALE.../4„®,Q„. Revisions: No. Date Description Drawn: Issue Date: J. D. 06,10, 2019 r'r . a I.C.E.D. Services LLC. Independent Coordinators for Engineering & Drafting Services (352) 900-ICED Phone Jdiaz@ICEDServices.com Builder: XXXXX j XXXXXXX XXXX XXXXX XXXXX XXX-XXX-XXXX phone XXX'-XXX-XXXX fax mogamomommmm Project: Single Family Residence 3712 Tanager Place Fort Pierce, FL Jurisdiction: St. Lucie Co. moommimmmommmmmm Sheet Title: Elevations Sheet #:EMEMENINEEMMMUMMOM Engineer: Ed Shinskie, P.E. PE-47515 4707 Wild Turkey Rd. Mims, FL. 32754 (321)', 863-3223 phone TO THE BEST OF MY KNOWLEDGE, THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE W/ SECTION 1609 OF THE 2017 FJRIDA BUILDING CODE 6TH ED, Ici § Ed Shinskie, P.E. FL P.E. No. 47515 Revisions: No, Date Description FOIL BACK -I INSULATION CBS BLOCK WALL & LINTEL 1 "x2" P.T. FURRING STRIP EXTERIOR DRYWALL SIDING 1"x4" FOIL BACK P.T. INSULATION. ---- CBS BLOCK WALL TAPCONS SEE PRODUCT & LINTEL APPROVAL AFFIDAVIT FOR 1"x4" P.T. TYPE AND SPACING WOOD BUCK Ar Window Head EXTERIOR - Y2" DRYWALL SIDING 1 N2 P.T. FURRING 1 "x4" P.T. 1 "x4 P.T. STRIP ��\\WOOD BUCK 1 %2" P.T. FURRING STRIP Y2" DRYWALL - 1 "x4" P.T. 2X6 PT. ANCHOR TO. OLIDGARAGE DOOR TRACK, POUR CMU W/ 318" SI PSON FASTEN PER MFG SPEC. TITEN HD W/ MIN 2V2 .GAR. DOOR TRACK: EMBEDMENT INTO GONG. ROLLER MIN 1,Y4" EDGE DISTANCE HIGH WIND BRACE TO BE MAINTAINED 0 6" (PER MFG SPEC) FROM TOP AND BOT & - 8" O.C. THERE FTER CBS BLOCK - WALL r- GARAGE FOIL BACK INSULATION' t N2" P.T. FURRING STRIP GARAGE DOOR lid-• �I I( PANEL EXTERIOR SIDING DOOR BUCK DETAIL SCALE: 1-1/2" = 1'-0' DOOR THRESHOLD FASTEN 1"x4" P.T. W/ TAPCONS AS PER PRODUCT APPROVAL DOOR PANEL IF 1x P.T. BUCK USED FOIL BACK THAN A"Ox2Y'4" TAPCONS ATTACH P.T. DOOR BUCKS CBS BLOCK INSULATION THRU DOOR FRAME AS IN SUCH AS WALL ATTACH P.T. DOOR BUCKS IN SUCH A 7n PER PRODUCT SPECS MINIMUMR TO AS A MINIMUM COVER MANNER. AS TO AS A MINIMUM COVER THE (SEE PRODUCT APPROVAL THE ENTIRE WIDTH (AS .EXTERIOR ENTIRE WIDTH (AS MEASURED FROM.. INSIDE CBS BLOCK WALL AFFIDAVIT). MEASURED FROM INSIDE SIDING TO OUTSIDE) OF PREHUNG-DOOR JAMB. IF 2X P.T. BUCK USED TO OUTSIDE) OF -PREHUNG IF Ix P.T. BUCK USED THAN Y4"0x2Y4" THAN 36%,3Y4" TAPCONS DOOR JAMB. TAPCONS THIRD DOOR FRAME AS PER SPACED AS PER PRODUCT SPECS (SEE PRODUCT APPROVAL PRODUCT APPROVAL. AFFIDAVIT). CONS SEE PRODUCT TAPAPPROVAL AFFIDAVIT EXTERIOR FOR IF 2X P.T. BUCK USED THAN N6"x2h" SIDING TYPE AND SPACING - i TAPCONS SPACED AS PER PRODUCT APPROVAL. PDoor Window Jamb Door Head Jamb TYPICAL WINDOW AND DOOR BUCK DETAILSSCALE: 1-1/2" = V-0" GENERAL NOTES: R703.8 FLASHING JOB SPECIFIC GENERAL NOTES: -RESISTANT FLASHING SHALL BE APPLIED APPROVED CORROSION ES NG i' THEBUILDER SHALL REVIEW DRAWINGS IN THEIR ENTIRETY BEFORE U SHINGLE -FASHION. IN A MANNER TO PREVENT ENTRY OF WATER INTO THE 1. HOUSE IS IN A NEGLIGIBLE WEATHER AREA L WEA H WORK, THE BUILDER SHALL ACCEPT FULL RESPONSIBILITY FOR ANY ERROR OR WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL OMISSIONS NOT REPORTED IMMEDIATELY IN WRITING TO ENGINEER OF RECORD. FRAMING COMPONENTS. SELF -ADHERED MEMBRANES USED AS FLASHING 2. HOUSE IS IN A VERY- HEAVY TERMITE AREA. BY SUBMITTING THESE PLANS FOR PERMIT THE BUILDER ACCEPTS FULL SHALL COMPLY WITH AAMA 711. THE FLASHING SHALL EXTEND TO THE RESPONSIBILITY FOR THE ACCURACY OF THE INFORMATION DEPICTED WITHIN SURFACE- OF THE EXTERIOR WALL FINISH. APPROVED 3. FLAME SPREAD FOR WALLS AND CEILING AND IT IS ASSUMED THE BUILDER HAS READ AND UNDERSTANDS THE NOTES CORROSION -RESISTANT FLASHING SHALL BE INSTALLED AT ALL OF THE FINISHES SHALL BE LESS THAN 200. BELOW, FOLLOWING LOCATIONS: DESIGN LOADS 1N ACCORDANCE WITH 2O17 FBC 6TH EDITION CHAP. 16 4. FLAME SPREAD FOR INSULATION SHALL BE LESS W OPENINGS. FLASHING AT EXTERIOR 1. EXTERIOR- WINDOW AND DOOR 0 E GS. THAN 25 ASSUMED SOIL BEARING CAPACITY: 2500 PSF WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER 5. SMOKE DEVELOPED INDEX SHALL BE LESS THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB FOR SUBSEQUENT DRAINAGE: FLASHING AT EXTERIOR WINDOW AND 4501 FOR WALL FINISHES, CEILING FINISH AND SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR INSYLATION SITE DRAWINGS MORE OF THE FOLLOWING OR OTHER APPROVED METHOD: 6. GYP UM BOARD SHALL CONFORM TO FBC CONSULT ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER 1.1. THE FENESTRATION `MANUFACTURER'S WRITTEN FLASHING I R70 3 STANDARDS DETAILS .NOT SHOWN ON STRUCTURAL DRAWINGS. INSTRUCTIONS. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE 1.2. THE FLASHING MANUFACTURER'S WRITTEN INSTALLATION 7. i TILE IN SHOWERS MUST BE BACKED BY "DURA TYPICAL AND SHALL BE CONSTRUED TO ANY SIMILAR SITUATION ELSEWHERE ON INSTRUCTIONS. �RodK" CONCRETE BOARD OR EQUAL THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. 1.3, IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, OR FMA/WDMA 250. B. EGRESS WINDOWS COMPLY WITH 2O17 FBCR 6TH ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN FIELD. 1.4. IN ACCORDANCE W H THE FLASHING METHOD OF A REGISTERED EDITION R310.2.1 MIN. NET CLEAR OPENING OF - DESIGN PROFESSIONAL:' 5.0S.F. ', DO NOT .SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. IF ANY DISCREPANCIES ARE DISCOVER THE ENGINEER OF RECORD MUST BE CONTACTED 2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY 9. DRYER VENT TO OUTSIDE BEFORE THE COMMENCEMENT OF CONSTRUCTION. CONSTRUCTION WITH FRAME OR STUCCO: WALLS, WITH PROJECTING THE STRUCTURE IS DESIGNED TO SELF SUPPORTING AND STABLE AFTER LIPS ON BOTH SIDES UNDER STUCCO COPINGS. 10. LOWI FLOW PLUMBING FIXTURES - BUILDING IS COMPLETE. AND AT THE ENDS OF MASONRY WOOD OR METAL COPINGS 3. UNDER i IT IS C THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SILLS. TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. TEMPORARY' BRACING, GUYS OR TIEDOWNS THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND 5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A< WALL SITE PREPARATION REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION; CONSTRUCTION LOADS. 6. AT WALL AND ROOF INTERSECTIONS. THE STRUCTURAL FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER, THE 7 AT BUILT-IN GUTTERS. SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL FLOOR DESIGNERS LAYOUT. PROVIDE SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS F APPROVAL. REVIEW OF SHOP DRAWINGS IS REQUIRED AS THE ENGINEER OR G Q BEAM CHECKS COLUMN AND FOOTING CAPACITIES AGAINST KNOW C WALL 0 LOADING, FAILURE TO PROVIDE SHOP DRAWINGS MAY RESULT IN ADDITIONAL ENGINEERING COSTS DURING CONSTRUCTION. AREA SCHEDULE LIVINGA/C 2,351 Sq Ft. GARAGE 507 Sq Ft. FRONTPORCH 170 Sq Ft. LANAI 111 Sq Ft. TOTAL 3,209 Sq Ft. ST. LUCIE COUNTY PRODUCT APPROVAL AFFIDAVIT BUILDWGPERMIT: BUILDING ADDRESS: See Border ICONTRACTOR: OPENING SCHEDULE`. SWING DOORS; OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS & SKYLIGHTS OPENING & ' GLASS ATTACHMENT METHOD NOA No. & PRODUCT DESIGN PRODUCE MODEL# MANUFACTURER DESCRIPTION TYPE, SIZE, SPACING &EMBEDMENT EXPIRATION PRESSURE DATE All SH Windows 1620 SH FL-21637.5-R3 +50.0/-50:0 Impact MI Windows & Hi -Impact 3/16" Tapcon with min 1-1/4" All Fixed Windows 1620-1630 Doors pentration of conc Thru All Mfg. Holes FL-21639.7-R2 +55.0/-55:0 PW Impact as per Product Approval 9080 Sliding Glass Door 420 Series Temp. - FL-15332.5-R4 +42.9/42.9 1/4" Tapcon with mini 1-1/4" pentration All Swing Man Door with & Fiberglass Therma-Tru Hi -Impact of conc Thru All Mfg: Holes as per FL-15037.3-R3 +50.0/-50:0 without Sidelights Corporation Product Approval ATTACHMENT METHOD NOA No. & PRODUCT DESIGN PRODUCT MODEL# MANUFACTURER TYPE, SIZE, SPACING EMBEDMENT &STIFFENER ETC. EXPIRATION PRESSURE DATE DAB Door 5/16"x15/8" Lag screws thru steel bracket into P.T. 17-0919.11 16080 Garage Door HIM 824/811 Company Buck @ spacing decribed in product approval 3/29/2022 +40.0/ 44:0 Mullions M-2285 Vert. MI Windows &Doors As per Mfg. Specs FL-18504.4-R3 +33.9/-33.9 Roof Shingles Oakridge Owens Coming (6) 8d Mngshank nails ea. Shingle as per mfg. specs. FL-10674.1-R13 N/A Soffit Vent 4"x12" vented opening see typical wall section Shutter Bertha Eastern Metal 1/4" Dia X 1.3/4"-10 Sidewalk bolt embedded 7/8" into FL11964.1 +50.01-50.0 Alum. Supply conc. wall with wing nut @ 12" o.c. 6/22/2017 I have reviewed the above and approve it. (Enigneer of Record) NAME: SIGNATURE: CERTIFICATION NO: DATE: _ 16'-4» 18'-6" 12'-8" 9,_2„ 3'-4' W-10" 4'-2" 4'-2" 6'-2" 2'-4: (2) 3060 d- ----------- ------ -- ----------------------- --- -------- o -- - N `\ ?p 2 ^ ti� ; ' 0 \\ S0 d `° LANAI o, o I 00 ALL EXTERIOR CEILINGS TO i I MASTER ! I BE STUCCO OVER WIRE LATH AS DETAILED ON SHEET S3.0 00l BEDROOM 4'-8 DINING I 9080 S.G.D. M I v i I 0„ 4„ I i N i I in 3 -0„ 5'-10„ 2'-2" NV 3 f 3'00 GREAT ff Q.Ey ROOM„---- 12 1I4 RS ._. „ t2 R&S _ A o KITCHEN z f ' 0,; 3,_8„ 6, 4„ ; �. !� II 0 O N 1 W.I.C. ' i F co Li III 3, 1 0 O as l of I I I !i O D d :`gyp l WLC. _-. N 1 : l I IW�NE IREF�II I L _, 4 i I 3 6 2 t2,R& 2 - i 3 -:10 3 -6 6 -0 3 -6" i , -0 1 - " '- " '-- 8 3 2 3 2 , " of i I REF: ! AH 1 L__ I� If1r�3080 2 _0„ 4„ _ ILn 1 ! BATH #2 4„ � _:- FNIN6 -- (5) 18, ------- - I F 2'- -0» 3'-8o 8'_ ' 9'-4" a 4'-0» 6 -0" -8^ 2„ PANTRY 0 11 _ _. 14 080 4 4" 4" 4„ „ SHELVES B.F. - LAUNDRY 0 _ (5) 16" !I� SHELVES I p-`----- W: --; 4<r SHELVES d11111111 (5) 16" IF d'mw 1 o PO e o SHELVES -- - MASTER "� BATH o II 12" 11'-0" o 0 O il� ; R&s ENTRY 8„ 12' co _I BR #3 oz� $R #1 °� 1 l i ° ! owl , R&S I - „ 4„ _. _ 4„ 4, 4„ 4'4 - - 11'-4" A, 6'-0" 3'-8" 11' Q" TIL LASS TUB ON „ --------- 20" DECK 6 4„ 10" SH o 'S�11 cO i o of II i ow, --- ----- ❑__________________ cv285 jloou>_� 5080 7 1 02 (2) 3060 N FIXED FIXED S.H. BE 12 B.F. - 3-4 7'-4„ o I 20„ 4,-0„ I 14'-0" 4'-0" - 10'-0" FLAT ;- --- - t_.: 0 0 CEILING 123'-8" 5'-0" r I� r ALL EXTERIOR S' OR CEILING TO GUEST BATH 1' I 0 w I BE STUCCO OVER WIRE LATH FRONT PORCH TAILED ON 5 80 B.F. 6„ I ----------AS -DE_S3.0 j3 o --- ro 3 S. t co 12„ _ ,_ - c� __ to . io 12" R&S 1. " 5'-2" 8' 11 o 16" 10'-8" 16" 10'-6" W.H. 6" BEARING -.� WALL " - - 1 g" 4"x6" PSL COL SETT 3080 0 IN SUCH A WAY TO ALLOW 2" CLEARANCE BETWEEN DRYWALL AND POST GARAGE d -0 I M N. N N N N - N - ------------------------------ -- - , 1 1 I DEL. VERT. CELL REQUIR D ON BOTH iI i i g, 4„ 12'-8" 11-10" 3'-4„ SIDES OF GARAGE DO R OPENING 16'-0" 3'-6>, 33'-10" 22'-10" 56'-8,� e. Drawn: Issue Date: J.D. 06.10.2019 I.C.E.D. Services LLC. Independent Coordinators for Engineering & Drafting Services (352) 900-ICED Phone Jdiaz@ICEDServices. com RI ,Ilrip-r a ry �, CUMMINGS�' -CUSTOM FIOME.S - 0.014, i Smart 1 0.... VGI L111VU 1"1GJIl.AG1 ItIQI Contractor FL#: CRC1331434 3310 SW Savona Blvd. Port St. Lucie, FL. 954-353-0836 Office 954-304-3755 Mobile Project: 3712 Tanager Place Fort Pierce, FL Jurisdiction: St. Lucie Co. Sheet Title Floor Plan, Buck Details, & General n SP ecificatiO S Sheet #(: /-l�� . 1J Z .. Ed Shi'i kie, P E. , � PE-47515 4707 Wild Turkey Rd. Mirn% FL. 32754 (321) 863-3223 phone TO THE BEST OF MY KNOWLEDGE, THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE W/ SECTION 1609 OF THE 2017 FLORIDA BUILDING CODE 6TH ED. FLOOR PLAN _ SCALE: Y4"-1'-01' Ed Shinskie, P.E. FL P.E. No. 47515 THICKENED EDGE W/ (1) #5 REBAR & CORNER BENDS GRADEQ •. a .4".4LAB ° #5. FOOTER STEEL W/ k��- 10" BEND IN FOOTER 8„ ° #5 FOOTER STEEL W/ 10 AND MIN 60 BAR (25") BEND IN FOOTER AND MIN n LAP ON VERT. STEEL TJ� 11 60 BAR (25") LAP ON VERT. n I ICE N E I) E D G E STEEL ® 4' 4" sLAe: a S ALE: 3/41,_0" 16"x18" CONT GRADE d. 4. ,SLAff° a ED FIR W/ (2) ° 16"x18" CONT. FOOTER #5 REBAR W/ GRADE a 4°.SLA6'" a' W/ (2) #5 REBAR W/ CORNER BENDS ° d' CORNER BENDS 1'-4" o °I __— T R 16"x14" CONT FOOTER 71�JL' ® TER S 1JA1J °. W/ (2) #5 REBAR W/ 1'-4" CORNER BENDS TYPICAL EXT. E ELECT. CHANGE SCALE: 3/4„=V-0" SCALE: 3/4„_1,_®„ YYP �I CAL PATIO F T SCALE. 3/¢"-1'-0" #5 FOOTER STEEL W/ 10" AV BEND IN FOOTER AND MIN 60 BAR (25") LAP ON VERT. VERT. STUD ® 16" O.C. #5 FOOTER STEEL W/ 10" STEEL BEND IN FOOTER AND MIN o 60 BAR (25")LAP ON VERT ° GARAGE CURB' kz"X6" LONG EXPANSION STEEL BOLT Q 32" O.C. SHOWER RECESS GARAGE FLOOR d 4' SLAB' . GRADE � GRADE � CFOOTER ° ° 4" SLA<4 SLl�B 9U 4' SLAB "06" CONT. 10 W/ (2) :10 REBAR W/ N CORNER BENDS � 16"x14" CONT. FOOTER 1'-4" 16'x12" CONT FOOTER � — —._ - W/ (2) #5 REBAR W/ C(� CORNER BENDS (2) #5 REBAR W/ CORNER BENDS FOOTER Oc INTERIOR CO SDI®�'YE RECESS �X'h" FTR. `GARAGE (7y�� EEAP'�NG TALL SCALE: 3/4„=1,_0„�SCALE: 3/¢ 1—�SCALE: 34"=1'-0„ STRUCTURAL SUPPORT CONCRETE NOTES: SEE INT. BEARING COL SECTION FOR SPECS 4" CONCRETE HAS BEEN PERFORMED IN ACCORDANCE WITH ACI 318-05, BUILDING — CODE REQUIREMENTS FIR STRUCTURAL CONCRETE A 4" SLABa.' ° a40 NORMAL WEIGHT CONCRETE (145 PCF) 28-DAY COMPRESSIVE STRENGTHS. PILING 500 PSI WITH .40 WATER -CEMENT RATIO 4 ° 4 LAB (D SHALLOW FOUNDATIONS 2500 PSI. ° <' PILE SUPPORTED FOUNDATIONS 5000 PSI WITH .40 WATER -CEMENT RATIO COLUMNS, BEAMS, AND ELEVATED SLABS, 3000 PSI. 24"x24"x18" °4 " CONCRETE SLUMP SHALL BE AS FOLLOWS SLUMP IN INCHES $ ISOLATED GONG M4X PAD W/ (3) #5 2 0 ) #5 MASSIVE SECTIONS, PAVEMENTS, AND SLABS YN HEAVY SLABS, BEAMS, WALLS 3" 5" REBAR EA. ,WAY THIN WALLS, COLUMNS 3u2" 6" ISOLATED MINIMUM CONCRETE CLEAR COVER SHALL BE: C O N SLAB PA l� AND BEAMS AND COLUMNS - 1Y2" F 8 TIE COLUMNS - -Y4" SCALE: 3/¢"=1'—�„ EXPOSED UNPROTECTED CONCRETE FORMED CONCRETE BELOW GRADE - 3" UNFORMED CONCRETE BELOW GRADE - 3" PLACING DRAWINGS AND BAR LISTS SHALL CONFORM TO A.C.L'S "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES."(A.C.I. ' 315) #5 FOOTER STEEL EPDXIED DETAILS OF CONCRETE REINFORCEMENT SHALL BE IN ACCORDANCE WITH MIN 6" INTO GONG AND Ml( . "MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION." 60 BAR LAP (25") ON AS PUBLISHED BY THE CONCRETE REINFORCING STEEL INSTITUTE UNLESS VERTICAL REBAR OTHERWISE INDICATED. ° 4 CONCRETE CONSTRUCTION TECHNIQUES SHALL CONFORM TO THE GRADE d 4"..SLAI " "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" (A.C.I. 301) ° FOOTER SEE ADEQUATE VERTICAL AND HORIZONTAL SHORING SHALL BE PROVIDED TO SAFELY ° FOUNDATION SUPPORT ALL CONSTRUCTION LOADS ate:. 4 FOR DETAILS CONCRETE BEAM SIZES MAY BE INCREASED AS REQUIRED FOR ARCHITECTURAL DETAILS OR TO FIT BLOCK COURSING_ MISSED E L D T CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF A.C.I 301 AND ASTM C-94 FOR MEASURING, MIXING, TRANSPORTING, ETC. SCALE: 3/¢"=1'-0" CONCRETE TICKETS SHALL BE TIME -STAMPED WHEN CONCRETE IS BATCHED. 2" FLU THE MAXIMUM TIME ALLOWED FROM WHEN WATER IS ADDED TO THE MIX UNTIL VENT DQl IT -1S DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES. IF SINK . FOR ANY REASON THERE IS A DELAY SUCH THAT A BATCH IS HELD FOR LONGER THE 90 MINUTES, THE CONCRETE SHALL NOT BE PLACED. 2" 2" V.T.R. BRUSH CONCRETE SURFACE V CONCRETEQ L t R ER HOLE THAN ALL THREAD ROD DRILOR /B" LA G)NYLON REBAR. CLEAN OUT WITH BLOWOUT BULB. COMPLETE HOLE PREPARATION WITH USE OF A J BRUSH (DO NOT USE WIRE BRUSH) EPDXY TUBE CONCRETE SURFACE. Q EPDXY Q CONCRETE 4 PRIOR TO INJECTION, DISCHARGE ONE FLUID OUNCE OF EPDXY OR UNTIL UNIFORM IN COLOR. 2 FILL THE HOLE TO 1/2 THE. HOLE DEPTH. EMBEDDED BOLT CONCRETE SURFACE OR REBAR o A R 6" MIN. Q 1/ Q j QCONCRETE i 7 INSERT ALLTHREAD ROD OR REBAR SLOWLY BY HAND INTO THE HOLE TO THE END USING A SLOW TWISTING MOTION. HARDENING WILL BEGIN IN 7 3 MINUTES AT ROOM TEMPERATURE. IMPORTANT DO NOT LOAD FOR 3 DAYS. EPDXY INSTALLATION PROCEDURES CALCIUM CHLORIDES SHALL NOT BE UTILIZED IN THE WORK. _1 OTHER ADMIXTURES MAY BE USED ONLY WITH THE APPROVAL OF THE ENGINEER. , ' I i 2" V.T.R. FBC PROVIDES AN EXCEPTION FOR RESIDENTIALCONSTRUCTIONWHERE CONTROL 1' 2 iII Jl` JOINTS ARE NOT REQUIRED. HOWEVER, IN THAT EXCEPTION, IT SAYS THAT THE i �0�.1 EXCEPTION IS ALLOWED WHERE THE OWNER ACKNOWLEDGES THAT CRACKS ARE ACCEPTABLE AND UNDERSTOOD. ^ram__-_-_- _2r'� i 2, FORMWORK: i V I FORMWORK SHORING AND BRACING FOR ALL CONCRETE BEAMS,. COLUMNS e 2" V.T.R WALLS AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE I WITH A.C.I 347, "RECOMMENDED PRACTICE FOR CONCRETE FORMWORK". l LAV. z„ ANY AND ALL PLUMBING PIPE PENETRATIONS THROUGH FORMED WORK SHOULD 3° a -AV. BE DONE SO THAT REINFORCING STEEL IS NOT DISRUPTED AND COVER FOR 2 ` .• I Z„ 2 TUB STEEL IS NOT AFFECTED 3° P. I W.C. 2" W.C. " 0 �0. �LAV ANY UTILITY PIPES PENETRATING FOOTERS TO BE PROPERLY SLEEVED TO AVOID v �E�T' PIPED UTILITIES FROM BEING SHEARED DURING SETTLEMENT OF STRUCTURE i 3 TUB: ELECTRICAL PIPES INSIDE OF THE POURED COLUMNS SO THAT THEY DO NOT TAKE UP MORE THAN 10% OF THE CROSS -SECTIONAL AREA OF THE COLUMNS W'C' '� 3f AND THEY DO NOT AFFECT THE COVER ON THE REINFORCING STEEL ' WELDED WIRE MESH: 2 LAV. i 4" Co. WELDED WIRE MESH SHALL BE ASTM A185, GRADE 65, FREE FROM OIL, SCALE, TUB AND RUST AND SHALL BE PLACED IN ACCORDANCE WITH ACI TYPICAL DETAILS. 2 T 2' 4" TO APPROVED MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. SANITARY SYSTEM 2 16'-4" 12'-2" 4'-2" i 18'. 56'-8" 12'-8" — 8,-6„ �... ' ----- - ------------------.------ �° --- 1 F I512 ZI/ 1 I 1 I 00 • I S1 0 cc I I d 4" I j • I : S1 I I____________________ 47'-6" I ' I I 1; I; .I I 1. I; 1 I_ o I 1 1 1 .I 1 1 ; I I: .I 1, I • � :I j4" I 2500 PSI CONC SLAB W/ FIBERMESH REINFORCEMENT OVER 6 MIL VISQUEN I I. 1 I I 1 1 - LAPPED 6" OVER CLEAN, TERMITE TREATED FILL COMPACTED, TO 95% ENSIiY IN MAX 6" LIFTS I I F.F.E. a I , O'_0" Ell L, Fg S1 1 :I I. 0 I 1 q» -01 2'-N3" •I (" 18' 6" I I I� r 2 F8 1 14„ S1 1 1 C,4 1 S r^ — 26'—B" N ) S 123'-8" -4'* I 2 o i, 1 I ; 5'-0" S 19'-4" rn ° 1 F6 I 2 S I S 1 I S r----- - F8 1 --------- -------0 F6---- ---� I S1 1 S1 --- — 1 1 I c S1 5'-2" ' L- � I �� o I T-4" 12'-8" 11'-10„ I 12'-1 2'-0" 8'-0" I d -2" 4„ 12' 4„ --- -1----- 1 0 S -4'* I I L f � 4'-0„ I o Ld I 5 I N I S o 1 N N I 1 I N i I I I I: I , I I L N I--- S --J SLOPED 1 " + SHOWER Z" I 3'-4"16' 0" S-6„ Revisions: No. Date Description Drawn: Issue Date: J.D. 06.12.2019 I.C.E.D. Services LLC. Independent Coordinators for Engineering & Drafting Services (352) 900-ICED Phone Jdiaz@ICEDServices.com mmmommommommmmmm UMMIMTG °CUSTOM 1HOME$ L16htYry (S%atS (Bran¢ 3712 Tanager Place Fort Pierce, FL Jurisdiction: St. Lucie Co. 111111111111111 Sheet Title: Foundation Plan Sheet #: ' S1'.Q Engineer: Y Ed Shinskie, P. E PE-47515 4707 Wild Turkey Rd. Mims, FL. 32754 (321) 863-3223 phone TO THE BEST OF MY KNOWLEDGE, THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE W/ SECTION 1609 OF THE 2017 FLORIDA BUILDING CODE 6TH ED. SANITARY RISER 33'-10" 22'-10" FOUNDATION PLAN SCALE. Y,4„_1,-0" SCALE: N.T.S. Ed Sh inskie; P.E. FL P.E. No. 47515 MASONARY NOTES: STRUCTURAL DESIGN IS IN ACCORDANCE WITH A.C.1530-05/ASCE 5-02/TMS 402-02, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY ON BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES. CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.1530 05/ASCE 6 02/TMS 602-02, SPECIFICATIONS FOR MASONRY STRUCTURES AND THE COMMENTARY ON SPECIFICATIONS FOR MASONRY STRUCTURES. ALL BLOCK WALLS SHALL BE TWO CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK MANUFACTURED iN CONFORMANCE WITH ASTM C 90, GRADE, F'm=1500 P.S.I. BLOCK SHALL BE PLACED IN RUNNING BOND UNLESS OTHERWISE NOTED. LAY UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE PLACING CONCRETE FOR IN WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH ASTM C-476 AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 P.S.I AT 28 DAYS. THE GROUT MIX SHALL HAVE A MAXIMUM 3/8" COURSE AGGREGATE AND SHALL BE PLACED WITH A SLUMP OF 8" TO 10". USE MECHANICAL VIBRATION TO CONSOLIDATEGROUT. TYPE S MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270 HORIZONTAL AND VERTICALMORTAR JOINTS SHALL BE 3/8":: THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO THE CELLS TO BE FILLED. ALLOW A MINIMUM OF 24 HOURS FOR; MORTAR TO CURE PRIOR TO GROUTING CELLS. TENSION AND COMPRESSION LAPS = .002 X BAR DIAMETER X Fs (NOTE THAT Fs= 24 KSI MAXIMUM (.4 X Fy)) (THIS EQUATES TO 48 X BAR DIAMETER) MASONRY CONSTRUCTION SHALL BE PERFORMED UNDER THE DIRECT SUPERVISION OF A "CERTIFIED STRUCTURAL MASONRY CONTRACTOR". THE SUPERVISOR OF THE MASONRY PORTION OF THE PROJECT SHALL BE A "CERTIFIED STRUCTURAL MASONRY CONTRACTOR" OF A CERTIFIED STRUCTURAL MASON" AS RECOGNIZED BY THE FLORIDA CONCRETE AND PRODUCTS ASSOCIATION (FC&PA). THE SENIOR MASONRY SUPERVISOR WILL BE RESPONSIBLE TO ASSURE THAT THE WORK IS ACCOMPLISHED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. THE MASONRY CONTRACTOR SHALL SUBMIT CREDENTIALS FOR THE FC&PA TO THE ENGINEER FOR REVIEW AND APPROVAL PRIOR TO BIDDING. REINFORCING BAR SHALLBEIN ALL WALL INTERSECTIONS AND AT EACH SIDE OF ALL OPENINGS. , POURED DOWNCELL TO BE AT EVERY GIRDER LOCATION AND REINFORCING BARS SHALL BE AT ALL DBL. GIRDER TRUSSES REINFORCING STEEL NOTES: REBAR SHALL BE ASTM A615 GRADE 60 DEFORMED BARS, FREE FROM OIL, ANCE WITH THE TYPICAL BENDING CASTCRETE RECAST LINTEL SCHEDULE i- x C9 w x z IELD ADDED REBAR AT TOP 1-v , :MU. BOND BEAM BLOCK Roar FIELD ADDED REBAR AT BOTTOM BUI IOM KHWOKUNG PROVIDED IN LINTEL F = FILLED WITH GROUT / U = UNFILLED / S = SOLID QUANTITY OF FIELD ADDED R63ARATBOTrOM OF LINTEL CAVITY 8F16 - 1B/1T r NOMINAL WIDhLI 1 NOMINAL HBGFrr--lI QUA NTTTY OF FIELD ADDED REBAR AT TOP • '- • � I NDMA"I MARK LENGTH COMPOSITE BEAM SAFE GRAVI LOAD Y APPLIED GRAVITY LOAD SAFE UPLIFT LOAD APPLIED UPLIFT LOAD LB-1 1T4" 8F281B/1T 1849 <200 754 <200 LB-2 4'-6" 8RF221B/1T 6639 478 4224 266 LB-3 4'-6" 8F241B/1T- 8672 <200 4043 <200 LB-4 4'-6" SF241B/1T 8672 <200 4043 <200 LB-5 5'-4" 8F241B/1T 7342 <200 3607 <200 LB-6 5'-4" 8F241B/1T 7342 1040 3607 515 LB-7 10'-6" 8F241B/1T !, 2781 678 1458 292 LB-8 64' 8F24 1B/1T 7342 1155 3607 541 LB 9` 28'-0" teeLintel251 PSbox8-16" 2B/2T 103 298 190 LB-10 7'-6" 8F241B/1T 5681 1786 2571 846 LB-11 3'-6" 8F241B/1T 8974 <200 5591 <200 LB-12 T-6" 8F24IWIT 8974 <200 5591 <200 LB-13 T-6" 8F24IWIT 8974 <200 5591 <200 LB-14 3'-6" 8F241B/1T 8974 <200 5591 <200 LB-15 T-6" 8F241B/1T !, 8974 1809 5591 892 LB-16 T-6" 8F241B/1T 5681 793 2571 346, LB-17 4'-6" 8RF221B/1T 6639 629 4224 266 LB-18 4'-6" - 8F24 1B/1T 8672 <200 4043 <200 LB-19 6O 8F16 0B/1T I 2632 <200 2724 <200 LB-20 TWO 8F16 0B/1T 1254 <200 724 <200 LB-21 TWO 8F16 0B/1T 1254 358 724 303 SCALE, AND RUST AND PLACED IN ACCORD EL TO BE SUPPORTED ATY3 OF DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND SPECIFICATIONS. DISTANCE OR A M N MU#12 TO BE RS STEEL LINTEL. STEEL M OF 72 HOURS AFTER CONC,! POUR HORIZONTAL AND VERTICAL BARS SHALL LAP 60x BAR NO. SEE LAP SPLICE SCHEDULE UNSCHEDULED FIELD LAPS ARE SUBJECT TO ENGINEERS REVIEW.r '� I I' CELL TO BE TENSION LAP SPLICE SCHEDULE: i L_j FILLED AS PER TYP WALL SECTION PLAIN REINFORCEMENT BAR NO MASONRY SPLICE LENGTH OTHER THAN TOP BARS TOP BARS 3000 PSI 4000 PSI 3000 PSI 4000 PSI 3 - 16" 16" 21" 18" 4 24" 22" 19" 28" 24" 6 30' 27" 28" 3S' 30" 6 38" 35" 31" 46' 40" 7 42" 48". 42" 63" 64" PROVIDE CORNER BARS LAPPED AND TIED TO EACH BEAM REBAR, TYPICAL AT ALL CORNERS, THESE CORNER BARS SHALL BE THE SAME SIZE AS LONGITUDINAL BEAM BARS, SEE DETAILS FOR ADDITIONAL INFORMATION. REINFORCEMENT SHALL BE CAREFULLY PLACED, RIGIDLY SUPPORTED AND, WELL TIED WITH BAR SUPPORTS AND SPACERS. REINFORCING STEEL IN FOOTINGS SHALL BE ASSEMBLED AS MATS WITH BARS EQUALLY SPACED AND WIRED TOGETHER AT EACH INTERSECTION BEFORE - CONCRETE IS PLACED. DOWEL COLUMN AND WALL REINFORCING TO FOOTING WITH SAME SIZE AND ....NUMBER OE DOWELS AS. -VERTICAL BARS. ABOVE.:... DOWEL SHALL BE HOOKED "L" AT BOTTOM AND SHALL BE LAPPED 36 BAR DIAMETER WITH THE COLUMN OR WALL REINFORCING ABOVE. Powers11 i Ul DESII WDICAUS HERMOF GROUT HIOGHT017GOMPOSITIEUN 11 VARIES, SEE PLW AND BCHEAULM MASONRY WALL JY4"00" SEE FLOOR PLAN INTERIOR BEARING FOR DETAILS WALL SEE WALL SECTION FOR DETAILS TAPCONS 6" rPnkA Tr1P 4I'ln 1: f T Rr I O.U. IHLKL AFILK INT. BEARING WALL T� ASPHALT ROOFING ATTACHED CONNECTION MFG. SPECS AS PER MFG.'SPECS OVER (1) LAYER OF 30 LB FELT OVER OVER 1%2" PLYWOOD INSTALLED CBS "e ' _ es W/ 8d R O PRE—ENGINEERED STAGGERED AND 2 CBS WALL DETAIL FASTENED TO PRE-ENGINEERED TRUSSES 5 ANK NAILS @ 4" O.C. @ SCALE: 3/4 - 1 0 EDGES AND 6" ON CENTER IN FIELD R-30 BATT. INSULATION SEE TYPICALI WA SECTION MTL. DRIP- FOR ROOF ASS DETAILS EDGE Y2" ANTI -SAGGING OR 5/s" STANDARD DRYWALL MTL. STRAP SEE STRAP SCHEDULE FOR DETAILS DBL. 2"x6" TOP PLATE Y2 DRYWALL ZxIS" FIREBLOCK SET @ MIDPOINT OF WALL 2"x6" VERT. STUDS @ 16" O.C. Y2" ANTI -SAGGING OR %" STANDARD DRYWALL SIMPSON STRAP SP6 FASTENED W/ (6) 10dx1Y2" NAILS - DOOR AND WINDOW HEADERS TO BE 1/2" CDX PLYWOOD BETWEEN (2) NO. 2 2x12's AND JAMB STUDS W/ 16d FACE NAILS @ 12" O.C. (1) STUD FOR OPENINGS <6' (2) STUDS FOR OPENINGS 6' TO 10' (3) STUDS FOR OPENINGS 10' TO 16' SEE NOTES FOR OPENINGS >16' Y2" DRYWALL R-19 BATT INSUL. J 2"x6" SOLE PLATE SIMPSON STRAP SP6 FASTENED W/ (6) [IF Y2"x10" TITEN 10dx%" NAILS H.D. ANCHOR @ 32" O.C. WOOD BASE BOARD FLOOR COVERING TO BE FOUNDATION SEE DETERMINED IN FIELD SHEET S1 FOR DETAILS a a_ c ' �. am' a INT. BEARING ALL DETAIL SCALE: 3/4"_V--0" 2"x6" FASCIA 2'-0" 4"x12" VENT OPENING W/ RODENT SCREENING - @ 6' O.C. MAX STUCCO SOFFIT STUCCO SIDING- Y2" ANTI -SAGGING OR 5/s" STANDARD DRYWALL MTL STRAP SEE STRAP SCHEDULE FOR DETAILS d DBL. COURSE OF BEAM BLOCK W/ (1) #5 CONT. REBAR W/ CORNER BENDS FILLED W/ 3000 a o PSI CONC EA. COURSE a 0 Y2" DRYWALL #5 REBAR W/ 10" BEND IN BEAM IN FILLED CELL W/ 3000 PSI CONC. @ 6'-0" O.C. MAX` 3'4" FUR STRIPS ON 1" RIGID BOARD. GLUED TAPE AND SEAMED TO BLOCK SEE SHEET S1.0 FOR FOOTER STEEL DETAILS WOOD BASE BOARD, FLOOR COVERING TO BE DETERMINED IN FIELD a`,� =mwziw. SEE SHEET S1 FOR FOOTER DETAILS G PCAL; WALL SECTION SCALE: 3/4-1'-0" CEILING BEAMPLAN SCALE Y4,5_1,_0„ Revisions: No. Date Description Drawn: Issue Date: J.D. 06,11 .2019 I.C.E.D. Services LLC. Independent Coordinators for Engineering & Drafting Services , (352) 900-ICED Phone Jdiaz@ICEDServices.com Immummommommmmmm Pi iNHr r gp,. NX C M I G ' -CUSTOM HOMES^°. Q..Isly I S.." I W... Certified Residential Contractor FL#: CRC1331434 3310 SW Savona Blvd. Port St. Lucie, FL. 954-353-0836 Office 954-304-3755 Mobile Project: 3712 Tanager Place Fort Pierce, FL Jurisdiction: St. Lucie CO Sheet Title: Cieli'ng/Beam Plan Sheet #: S2._0 Engineer: l v , Ed Shinskib, P.E '.- . PE-47515 4707 Wild Turkey Rd. Mims, FL. 32754 (321) 863-3223 phone TO THE BEST OF MY KNOWLEDGE, THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE W1 SECTION 1609 OF THE 2017 FLORIDA BUILDING CODE 6TH ED. Ed Shinskie, P.E. FL P.E. No. 47515 SEE TYR WALL SECTIONS FOR ROOFING SPECIFICATIONS 8D RINGSHANK NAILS @ 4" O.C. METAL DRIP EDGE I" X 6" CEDAR FASCIA 2" X 4" LADDER @ 24" O.C. ATTACHED @ BOTH ENDS WITH (2) 16D NAILS EACH END CONT. 2 X 4" SYP.OR BETTER 12" 0.H. 3/8" PLYWOOD ATTACHED W/ (3) 8D NAILS EVENLY SPACED @ EACH LADDER GABLE END TRUSS "LADDERED" SOFFIT DETAIL SCALE: 2"= I' DGE BOARD TO ACCEPT HIP CATS (2 X 12 MAY NEED TO IE CUT T MATCH SLOPE. NAILI WITH 3-16d NAILS PER END CATS SHALL BE EHIP CONTINUOUS TO RIDGE W/ 2 16d AILS P R ENO T. HIP GIRD R TRUSS ---- u. _... :S 2"X4" CONTINUOUS BLOCKING REQUIRED 4' UP FROM ROOF EDGE, NAILED W/ 2-16d ® EACH END. 1st SHEET ROW FROM EDGES SHALL BE FULL 4'X 8' SHEETS. ROOF SHEATHING NAILED 0 3"O.C. ON SUSFASCIA AND ® 4" O.C. ON THE REMAINING EDGES.(BLOCKING MAY BE INSTALLED ON THE FLAT OR ON EDGE.) -81D NAILS @ 6" O.C. -CONT. 2" X 4" SYR OR BETTER I WALL SUPPORT i HIP TRUSSES NAIL HIP JACK TRUSSES W/ --TOP CHORD 2- #10 COMMON BOTTOM CHORD 2-#10 COMMON —SUB-FASCIA BOARD ROOF SHEATHING TO BE CARRIED OVER 2 SPANS MINIMUM ® ALL LOCATIONS WOOD TRUSSES: ROOF / IRUSSES 2X'4DIAGONAL . BRACING 0 4'0.C. NAILED TO EACH TRUSS - W/2 416 4"X4" RATRUN FOR DIAGONAL BRACING 112" MIN GYPSUM EXTENDING BACK 8' DRYWALL GABLE END BRACING ATTACH SHEATHING @ 6" O.C. FIRST 3 TRUSSES SEE LADDER SOFFIT DETAIL 27 L-BRACE AS PER SCHEDULE 2-2' X 6" HEADER PER SCHEDULE 2"X4 BLOCKING @ 4 O.C. NAILED TO EACH TRUSS W/2-16D EXTEND BACK 8' '.GABLE END SHEATHING TO BE 112" CDX MIN. W'/ 8D RINGSHANK NAILS 6" O.C. EDGES AND 12" O.C. FIELD TYR. TRUSS ANCHOR SFF SCHEDULE GABLE END TRUSS BRACING CHART TRUSS HEIGHT TYPICAL 2X4 L—BRACE NAILED TO 2X4 'VERTICALS—W/16D NAILS 8' O.C. VERTICAL STUD ON TRUSS STUD 2'x6' HEADER / L-BRACE 2' X 4' DIAGONAL BRACE TOE -NAILED W/4-#16 TO HEADER L—BRACE NOT REQUIRED 0 T❑ 4'1' L—BRACE REQUIRED 4'2' TO T8' L—BRACE WITH HEADER 7'8' TO 14' GABLE HEADER SPACING L-BRACE WITH 2 HEADERS 14' TO 20' 1 HEADER PLACED AT CENTER OF TRUSS HEIGHT 2 HEADERS PLACED AT 1/3 AND 2/3 OF TRUSS HEIGHT NAIL END OF JACK TRUSSES W I TOP CHORD 3-16d COMMON '/ WOOD TRUSSES TO BE DESIGNEDAND FABRICATED IN ACCORDANCE WITH THE "NATIONAL BOTTOM CHORD 3-16d COMMON 16d NAIL HAS A MAXIMUM DESIGN SPECIFICATIONS FOR 'SDTRES§-GRADE LUMBER AND IT FASTENINGS"' BY NFPA LATERAL RESISTANCE OF 101 lbs. TRUSS DESIGN SHALL COMPLY WITH TPI/WTCABCSI 1-03 "BUILDING COMPONENT SAFETY INFORMATION GUIDE TO GOOD PRACTICE FOR HANDLING, INSTALLING, &` BRACING OF METAL JACK TRUSS CONNECTION PLATE CONNECTED` WOOD TRUSSES" AND TPI 1 02 "NATIONAL DESIGN STANDARD FOR ' HIP AND GIRDER TRUSSES 2"X4" CONTINUOUS BLOCKING REQUIRED 4' UP FROM ROOF .EDGE, NAILED W/ 2-16D @ EACI-I END IST SHEETS FROM EDGES SHALL BE FULL 4'X 8' SHEETS. ROOF SHEATHING NAILED @ 3"O.C. ON SUBFASCIA AND AT 4" O.C. ON THE REMAINING EDGES.(BLOCKING MAY BE PRE—ENG. WIRE LATH GABLE TRUSS BLOCKING REQUIREMENTS WIRE LATH SHALL BE ATTACHED ACCORDING TO ONE OF THE FOLLOWING METHODS (FINAL METHOD TO BE DETERMINED IN FIELD): 1. DIAMOND —MESH EXPANDED METAL LATH, FLAT —RIB EXPANDED METAL LATH AND WIRE LATH SHALL BE ATTACHED TO HORIZONTAL WOOD FRAMING MEMBERS WITH U¢" ROOFING NAILS DRIVEN FLUSH WITH PLASTER BASE. (ASTM 7.10.2.2) 2. EXPANDED %" RIB LATH SHALL BE ATTACHED TO HORIZONTAL WOOD FRAMING MEMBERS WITH NAILS OR STAPLES TO PROVIDE NOT LESS THAN 1-Y4" PENETRATION INTO WOOD FRAMING (ASTM 7.10.2.3) WITH EITHER METHOD THE SPACING OF FASTENERS TO BE 7" O.C. ALONG SUPPORTS AS PER ASTM 7.10.2.1 AS PER ASTM 7.10.2.4IF COMMON NAILS ARE USED THEY SHALL BE BENT OVER TO ENGAGE NOT LESS THE `THREE STRANDS OF LATH, OR BE BENT_ OVER A RIB IF RIB LATH IS INSTALLED METAL- P{ATE-CONNECTED W00 CONSTRUCTION TRUSS DESIGNS SHALL BE SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTES FOR SHOP DRAWING6. CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.036" AND BE MANUFACTURED FROM STEEL MEETING THE REQUIREMENTS OF ASTM A446, GRADE A, AND SHALL BE HOT -DIPPED GALVANIZED. \�WALLSUPPORj IN HIGHLY CORROSIVE ENVIRONMENTS, CONNECTOR PLATE-ASWELL AS THE HURRICANE STRAPS AND ALL THE NAILS, SHALL BE HOT DIPPED GALVANIZED, TRIPLE ZINC S 185 COATED OR MADE OF STAINLESS STEEL \ SUB FASCIA BOARD HANDLING, ERECTION, AND BRACING QF TRUSSES SHALL BE IN ACCORDANCE WITH TRUSS PLATE INSTITUTE RECOMMENDATIONS. HURRICANE STRAPS' SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. CONNECTORS OR STRAPS THAT DO NOT MATCH EXACTLY THE ONES' SPECIFIED IN THE ROOF SHEATHING TO BE DRAWINGS REGARDING STEEL YIELD OR ULTIMATE STRENGTH, STEEL GRADE, DIMENSIONS CARRIED BY 3 MEMBERS (LENGTH AND WIDTH), NUMBER AND DIAMETER OF HOLES FOR THE SAME SIZES OF NAILS MINIMUM OR BOLTS. AND/OR DONUT HAVE THE SAME GENERAL SHAPE, WILL NOT: BE ACCEPTABLE. THE CONTRACTOR WILL BE RESPONSIBLE FOR KEEPING THE ROOF SAFELY IN PLACE IN PLACE IN THE EVENT OF HIGH WINDS TRANSIENT LOADING CONDITIONS DURING CONSTRUCTION ***FAILURE TO COMPLY WITH THESE PARAMETER WILL MAKE THE CONTRACTOR ALL VALLEY TRUSSES SET OVER ROOF SHEATHING AND SHALL BE ATTACHED TO THE TRUSS BELOW W/ A SIMPSON STRAP AS 'LISTED 1N THE STRAPSCHEDULE IF NOT SPECIFIED BY TRUSS COMPANY VALLEY CONNECTION DETAIL SCALE: N.T.S. SOLELY RESPONSIBLE FOR ANY AND ALL CONSEQUENTIAL DAMAGES CAUSED BIT THE HORIZONTAL THRUST DEVELOPED BY THE ROOF FRAMING DUE TO SUPERIMPOSED LOADING AND TRANSFERRED INTO THE EAMS' WALLS, AND COLUMNS. CONTRACTOR SHALL SUBMIT SIG ED SEALED DRAWINGS OF ALTERNATE CONNECTION DETAILS AT TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL. THE ENGINEER AND ITS CONSULTANTS OR DESIGN PROFESSIONALS WILL NOT BE RESPONSIBLE FOR ANY DAMAGE CAUSED AS A CONSEQUENCE OF TERMITE INFESTATION THE LOCATIONS OF GIRDERS AND TRI SSES SHOWN ON THE ROOF FRAMING PLAN WERE USED TO FACILITATE DESIGN OF FOUNDATIONS, WALLS, AND BEAMS. THE CONTRACTOR SHALL SUBMIT TRUSS SHOP DRAWINGS FOR REVIEW BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO FABRICATION. THE TRUSS FABRICATOR SHALL ROV�DE ENGINEERED SHOP DRAWINGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED E ECTION PLAN SHOWING COMPONENT LAYOUT. 1� TS TRAPPING T n SCALE %g„-1,_�„ Revisions: j No. Date Description Drawn: Issue Date: v . D. 06,11 , 2019 �t I 1 i.C.E.D. Services LLC. Independent Coordinators for Engineering & Drafting Services (352) 900-ICED Phone JdiazglCEDServices.com Builder. lder. XXXXX XXXXXXX XXXX XXXXX XXXXX XXX-XXX-XXXX phone XXX-XXX-XXXX fax Project: Single Family Residence 3712 Tanager Place Fort Pierce, FL Jurisdiction: St. Lucie Co. Sheet Title: Truss Strapping Layout, Roof Framing Details, & Specifications Sheet #: S3.0 Engineer: Ed Shmskie, P.E. PE-4�515 4707 Wild Turkey Rd. Mims, FL. 32754 (321) 863-3223 phone TO THE BEST OF MY KNOWLEDGE, THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE W/ SECTION 1609 OF THE 2017 FRIDA BUILDING CODE 6TH ED. 1 e` �t Ed Shinskie, P.E. FL P.E. No. 47515 E Revisions: No. Date Description ELEGTRIGAL PLAN ELECTRICAL NOTES: 1. PROVIDE AND WIRE ALL REQUIRED SMOKE DETECTORS 2. CONTRACTOR TO VERIFY LOCATION OF ELECTRICAL SERVICE AND PROVIDER 3. ALL PADDLE FANS SHALL BE ON A RHE05TA7 4. RECE55ED CANS TO BE INSTALLED PER NFPA REQUIREMENTS 5. ALL ELEGTRIGAL DEVICES, APPLIANCES, A/C EQUIPMENT, PANELS, ETC... TO BE INSTALLED ABOVE THE MINIMUM FLOOD ZONE HEIGHT REQUIREMENT b. ALL BRANCH CIRCUITS THAT SUPPLY 125V SINGLE PHASE 15 AMP OR 20 AMP OUTLETS SHALL BE PROTECTED BY AN ARG-FAULT CIRCUIT BREAKER -7. TAMPER RESISTANT AFGI RECEPTACLES TO BE 6FI PROTECTED 9. ALL EXTERIOR OUTLETS TO BE HPI&H PROTECTED 10. A/G RETURN AIR BALANCE MUST COMPLY WITH F.B.G. MECHANICAL 2011 ED. AND CURRENT VERSION OF ANY SUPPLEMENTS TO THE 2011 EA II. AIG REFRIGERANT LINES THAT ARE RUN THRU 5LAB5 MUST BE SLEEVED IN PVC, 12. ALL A/C EQUIPMENT SHALL BE 15 SEER 13. PROVIDE DISCONNECTS AT ALL APPLIANCES (HATER HEATER, A/C UNITS, AND ALL OTHER EQUIPMENT AS REQUIRED BY N.E.C) 14."DUCTS IN GARAGE SHALL BE METAL OR I" THICK MINIMUM RIGID NONMETALLIC CLA55 O OR GLA55 I DUCT OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS IN THE 6ARA6E 15. SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOGATION5: A) IN EACH 5LEEPIN6 ROOM B) OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VIGINITY OF THE BEDROOMS 'G) ON EACH ADDITIONAL STORY OF THE DHELLIN6 ** ALL SMOKE ALARMS SHALL BE INTERCONNECTED AND HARDWIRED ** PER F.B.G. R3132.1 HHEN ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, HHEN A 5LEEPIN& ROOM 15 ADDED OR CREATED IN EXI5TIN6 DWELLINGS THE UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS A5 REQUIRED FOR NEH DWELLIN65. THE SMOKE ALARMS SHALL BE HARD HIRED AND INTERCONNECTED. 16. GARAGE 6FGI AND ALL EXTERIOR WIC7FGI TO BE ON SEPARATED CIRCUITS 17. ELECTRICAL SYSTEM TO INCLUDE THE INTERSYSTEM BONDING TERMINATION POINT (TWIST LOCK) PER FBC-R 201-7 E36O9.3 15. NEC, 210.12(3) -"ALL BRANCH CIRCUIT IN KITCHENS, FAMLY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOM5, 5UNROOM5, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS OR SIMILAR ROOMS SHALL BE PROTECTED BY A LISTED ARG-FAULT CIRCUIT INTERRUPTER, COMBINATION -TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH GIRGUIT." IN ADDITION TO AFGI PROTECTION NOTED ABOVE KITGHEN, AND GARAGE CIRCUITS SHALL BE 6FGI PROTECTED 1/U A/C DISCONNECT JLXN BREAKER PANEL #1 200 AMP 200 AMPS . METER ® Em Em 2" UG W/PARALLEL IN 2" CONDUIT LUGS 4/0 LYCONDUJIT COPPER TO FP&L TRANS. (2) 1/0 Cu + (1) 2/0 NEUT. SCHEDULE 80 (2) 4/0 TO METER LEGS RCOPPER RISER (1) 3/0 COPPER GRND #2 COPPER SERVICE ENTRY AND PANEL N TS ELECTRICAL SCHEDULE SYMBOL DESCRIPTION � 1 SINGLE POLE SWITCH $3 3 WAY SWITCH i S 4 WAY SWITCH i $D M DIMER SWITCH ' Q I i 110V OUTLET Vf �1� 110V HALF HOT OUTLET $220V 220V OUTLET \` t it WALL/ COUNTERTOP OUTLET d) DEDICATED OUTLET T PHONE OUTLET 4 CABLE OUTLET CEILING MOUNT FIXTURE WALL MOUNT FIXTURE 0 RECESSED CAN FIXTURE ® AIMABLE RECESSED CAN FIXTURE ® EXHAUST FAN EXHAUST FAN WITH LIGHT FLUORESCENT FIXTURE I---r OVER OR UNDER COUNTER LIGHT i I a GARBAGE DISPOSAL 4G GARAGE DOOR OPENER r i 4DB DOOR BELL ® DOOR CHIME SQ SMOKE DETECTOR i r® MOTION DETECTOR LJ DISCONNECT SWITCH i 1=� Ott I ® STEP LIGHT I+ ELECTRICAL METER p ELECTRICAL PANEL CEILING FAN CEILING FAN W/ LIGHT NOTES/ ABBREVIATIONS° r VP VAPOR PROOF WP WATERPROOF GFI GROUND FAULT INTERCEPTOR GD GARBAGE DISPOSAL 1) ALL OUTLETS IN KITCHEN; GARAGE, AND BATHS TO BE G.F.I. 2) BEDROOM OUTLETS TO BE ARC FAULT PROTECTED (AFCI) 3) ALL RECESSED CANS TO BE INSULATED 4) ALL LIGHTING TO BE LED OR COMPACT FLUORESCENT(CFL) —11 Drawn: Issue Date: J.D. 06.12.2019 I.C.E.D. Services LLC. Independent Coordinators for Engineering & Drafting Services (352) 900-ICED Phone Jd i az@ rC E D Servi ces. co m ,-,.. ,-,.__. %' UMMINGS' CUSTOM HOMES°-- Q'i"ip € $..It 1 01.. Certified Residential Contractor FL#: CRC1331434 3712 Tanager Place Fort Pierce, FL Jurisdiction: St. Lucie Co mommommmmommmmm Sheet Title: Electrical Layout Sheet #: E1.0 Engineer: