Loading...
HomeMy WebLinkAboutLetter; Respomses to Comments11A..0F_` `Archit¢ctonic Inc St. Lucie County Building Department Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982 December 5, 2019 RE: 8631 S US Hwy 1 Permit # 19 �61[ 9 To Whom It My Concern ItECENEo DEC :0 8 1019 Pe St. L gie counLmVent Please accept the following responses to the comments dated 2/7/2019 from your agency. Response shown on plans corresponding (if required) to these comments are noted. *PLEASE PROVIDE A COMPLETE SET OF PLANS TO START PLAN REVIEW. THERE MAY BE ADDITIONAL COMMENTS WHEN A COMPLETE SET IS RECEIVED. ([A] 107.2.1) Response: SEE ATTACHED *DRAWINGS MUST BE SIGNED AND SEALED BY A DESIGN PROFESSIONAL. ([A] 107.1) Response: SEE ATTACHED *FLOOR PLAN -PLEASE SHOW THE LOCATION OF THE PLUMBING FIXTURES AND GRAB BARS IN THE RESTROOMS. SHOW ACCESSIBILITY TO THE RECEPTION DESK. SHOW THE SPACE REQUIRED FOR THE DOOR MANEUVERING CLEARANCE AT THE FRONT DOOR. ([A] 107.2.10 Response: SHOWN ON SHEET A-1 *CEILING PLAN REQUIRED -SHOW LOCATION OF NEW AND EXISTING LIGHTS, DUCTS AND CEILING MATERIAL. SHOW EXIT SIGNS AND EMERGENCY LIGHTIG. ([A] 107.2.1) Response: ALL LIGHTING INCLUDING EXIT AND EMERGENCY LIGHTING ARE EXISTING TO REMAIN ALONG WITH CEILING AND HVAC DUCT WORK SINCE WALLS ARE BELOW CEILING *UPDATE THE BUILDING CODE INFORMATION INCLUDING THE CORRECT GROUP/OCCUPANCY AND OCCUPANT COUNT. ([A] 107.2.1) Response: SEE BUILDING INFORMATION SHEET A-1 *PROVIDE AN UPDATED SPRINKLER LAYOUT. ([A] 107.2.1) Response: NO SPRINKLER MODIFICATION REQUIRED SINCE THE WALLS ARE 210" BELOW CEILING 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 2 " Architectonic Inc *PROVIDE AN ELECTRICAL PLAN, SHOW NEW AND RELOCATED CIRCUITS, SHOW POWER SOURCE FOR ALL EQUIPMENT AND APPLIANCES. ([A] 107.2.1) Response: SEE PLAN FOR LOCATION OF NEW OUTLETS *PROVIDE A MECHANICAL PLAN WITH RELOCATED DUCTS. ([A] 107.2.1) Response: NO DUCTS BEING ADDED JUST A TRANSFER GRILL *PLEASE PROVIDE THE REQUIRED FIRE PERFORMANCE AND SMOKE DEVELOPMENT INDEXES FOR ALL FINISHES. (801.1) Response: SEE SHEET A-1 *PLEASE PROVIDE FRAMING DETAILS FOR INTERIOR WALLS. INCLUDE FASTENERS REQUIRED AT TOP TRACK, AND FASTENERS REQUIREMENTS TO ATTACH GYP. BD. TO FRAMING (2501.1) Response: SEE WALL SECTION A-1 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 2 of 2