Loading...
HomeMy WebLinkAboutBuilding permit app17 16 15 Egress 14 13 12 11 10 9 8 76 5 4 3 2 Egress 1 Main Door, Egress 2322 21 20 19 18 PAGE: 1 OF 1 PAGE DESCRIPTION: Site Plan DATE: Oct 23, 2020 SCALE: NOT TO SCALE COPYRIGHT E-TEMPEST.COMMarcie Brown5003 El Nueva AvenueFort Pierce, FL 34946Opening Size (W x H) 1.35 x 80X Outswing Door (Series 160) 17-1226.05 2.74 x 58OX Horizontal Rolling Window (Series 3200) FL15814.1 3.74 x 58XO Horizontal Rolling Window (Series 3200) FL15814.1 4.74 x 46OX Horizontal Rolling Window (Series 3200) FL15814.1 5.74 x 46XO Horizontal Rolling Window (Series 3200) FL15814.1 6.44 x 72Single Hung Window (Series 3100) FL15699.1 7.36 x 72Single Hung Window (Series 3100) FL15699.1 8.36 x 72Single Hung Window (Series 3100) FL15699.1 9.44 x 72Single Hung Window (Series 3100) FL15699.1 10.53 x 76Single Hung Window (Series 3100) FL15699.1 11.76 x 53XOX Horizontal Rolling Window (Series 3200) FL15814.1 12.36 x 24XO Horizontal Rolling Window (Series 3200) FL15814.1 13.36 x 24XO Horizontal Rolling Window (Series 3200) FL15814.1 14.36 x 24XO Horizontal Rolling Window (Series 3200) FL15814.1 15.74 x 50XO Horizontal Rolling Window (Series 3200) FL15814.1 16.52 x 50XO Horizontal Rolling Window (Series 3200) FL15814.1 17.74 x 46XO Horizontal Rolling Window (Series 3200) FL15814.1 18.37 x 50Single Hung Window (Series 3100) FL15699.1 19.37 x 77Single Hung Window (Series 3100) FL15699.1 20.37 x 77Single Hung Window (Series 3100) FL15699.1 21.37 x 77Single Hung Window (Series 3100) FL15699.1 22.37 x 73Single Hung Window (Series 3100) FL15699.1 23.29 x 71Fixed Window (Series 3000) FL17162.1 MRH 12' BedroomBathRoom BedroomWindow Matchs existing Window BathRoom Bedroom Living Room Family Room Kitchen Property Information Owner:Marcie Brown Address:5003 El Nueva Avenue Fort Pierce, FL 34946 Building Information Wind Zone:160 MPH. Exposure Category:C Minimum Building Dimension:15 ft. Mean Roof Height:12 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 35 80 7 32.0 -34.9 2 Int 74 58 7 31.1 -33.9 3 Int 74 58 7 31.1 -33.9 4 Int 74 46 7 31.6 -34.4 5 Int 74 46 7 31.6 -34.4 6 Int 44 72 7 31.8 -34.6 7 Int 36 72 7 32.2 -35.0 8 Int 36 72 7 32.2 -35.0 9 Int 44 72 7 31.8 -34.6 10 Int 53 76 7 31.2 -34.1 11 Int 76 53 7 31.2 -34.1 12 Int 36 24 7 33.5 -36.3 13 Int 36 24 7 33.5 -36.3 14 Int 36 24 7 33.5 -36.3 15 Int 74 50 7 31.4 -34.3 16 Int 52 50 7 32.2 -35.0 17 Int 74 46 7 31.6 -34.4 18 Int 37 50 7 32.9 -35.8 19 Int 37 77 7 32.0 -34.8 20 Int 37 77 7 32.0 -34.8 21 Int 37 77 7 32.0 -34.8 22 Int 37 73 7 32.1 -34.9 23 Int 29 71 7 32.7 -35.5 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1