Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building permit app
17 16 15 Egress 14 13 12 11 10 9 8 76 5 4 3 2 Egress 1 Main Door, Egress 2322 21 20 19 18 PAGE: 1 OF 1 PAGE DESCRIPTION: Site Plan DATE: Oct 23, 2020 SCALE: NOT TO SCALE COPYRIGHT E-TEMPEST.COMMarcie Brown5003 El Nueva AvenueFort Pierce, FL 34946Opening Size (W x H) 1.35 x 80X Outswing Door (Series 160) 17-1226.05 2.74 x 58OX Horizontal Rolling Window (Series 3200) FL15814.1 3.74 x 58XO Horizontal Rolling Window (Series 3200) FL15814.1 4.74 x 46OX Horizontal Rolling Window (Series 3200) FL15814.1 5.74 x 46XO Horizontal Rolling Window (Series 3200) FL15814.1 6.44 x 72Single Hung Window (Series 3100) FL15699.1 7.36 x 72Single Hung Window (Series 3100) FL15699.1 8.36 x 72Single Hung Window (Series 3100) FL15699.1 9.44 x 72Single Hung Window (Series 3100) FL15699.1 10.53 x 76Single Hung Window (Series 3100) FL15699.1 11.76 x 53XOX Horizontal Rolling Window (Series 3200) FL15814.1 12.36 x 24XO Horizontal Rolling Window (Series 3200) FL15814.1 13.36 x 24XO Horizontal Rolling Window (Series 3200) FL15814.1 14.36 x 24XO Horizontal Rolling Window (Series 3200) FL15814.1 15.74 x 50XO Horizontal Rolling Window (Series 3200) FL15814.1 16.52 x 50XO Horizontal Rolling Window (Series 3200) FL15814.1 17.74 x 46XO Horizontal Rolling Window (Series 3200) FL15814.1 18.37 x 50Single Hung Window (Series 3100) FL15699.1 19.37 x 77Single Hung Window (Series 3100) FL15699.1 20.37 x 77Single Hung Window (Series 3100) FL15699.1 21.37 x 77Single Hung Window (Series 3100) FL15699.1 22.37 x 73Single Hung Window (Series 3100) FL15699.1 23.29 x 71Fixed Window (Series 3000) FL17162.1 MRH 12' BedroomBathRoom BedroomWindow Matchs existing Window BathRoom Bedroom Living Room Family Room Kitchen Property Information Owner:Marcie Brown Address:5003 El Nueva Avenue Fort Pierce, FL 34946 Building Information Wind Zone:160 MPH. Exposure Category:C Minimum Building Dimension:15 ft. Mean Roof Height:12 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 35 80 7 32.0 -34.9 2 Int 74 58 7 31.1 -33.9 3 Int 74 58 7 31.1 -33.9 4 Int 74 46 7 31.6 -34.4 5 Int 74 46 7 31.6 -34.4 6 Int 44 72 7 31.8 -34.6 7 Int 36 72 7 32.2 -35.0 8 Int 36 72 7 32.2 -35.0 9 Int 44 72 7 31.8 -34.6 10 Int 53 76 7 31.2 -34.1 11 Int 76 53 7 31.2 -34.1 12 Int 36 24 7 33.5 -36.3 13 Int 36 24 7 33.5 -36.3 14 Int 36 24 7 33.5 -36.3 15 Int 74 50 7 31.4 -34.3 16 Int 52 50 7 32.2 -35.0 17 Int 74 46 7 31.6 -34.4 18 Int 37 50 7 32.9 -35.8 19 Int 37 77 7 32.0 -34.8 20 Int 37 77 7 32.0 -34.8 21 Int 37 77 7 32.0 -34.8 22 Int 37 73 7 32.1 -34.9 23 Int 29 71 7 32.7 -35.5 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1