BUSINESS - 1 148 SQ FT. / 100 = 12 PERSONS
OCCUPANCY CAPACITY: TOTAL 12
MAX. TRAVEL DISTANCE: 24FT
( 100 FEET ALLOWABLE)
PLUMBING FIXT REQ : W/M 1
( 1 PER 50 UNI - SEX)
NUMBER OF EXITS REQ : 1
OCCUP. LESS THAN 49
EGRESS TRAVEL LESS 100
NUMBER OF EXITS PROVIDED: 2
� k e
ELECTRICAL LEGEND
DUPLEX RECPT. 12" A.F.F.
�42"
DUPLEX RECPT. OTHER HGT.
REF.
DEDICATED RECPT. -..�
QUADRAPLEX RECPT
GROUND FAULT INTERUPTED
noG.F.I.
RECPT.
220V RECPT
EX
NEW
NEW
NEW
NEW
EX
EX
EX
-E�'}- SINGLE POLE SWITCH
-Ela co THREE WAY SWITCH
- Ek? - Q DIMMER SWITCH
INTERNET JACK
SD
SMOKE DETECTOR
Tv
TELEVISION COAXIAL
CARBON MONOXIDE
DETECTOR
Code Data:
OCCUPANCY CLASSIFICATION: BUSINESS ( B )
TYPE OF CONSTRUCTION: TYPE V-B
FIRE SPRINKLE SYSTEM: NO
NUMBER OF BUILDING STORIES: 1
PARTY WALL RATING: NA
ALL ELECTRICAL WORK TO COMPLY AND
VERIFY EXIST'G COMPLY WITH 2O14 NEC &
2017 FL BUILDING CODE
EXISTING CARPET FUG TO REMAIN (EXCEPT IN
TOILET - VINYL)
SAP CLG TO REMAIN
EXISTING ELECTRICAL POWER AND LIGHTING TO
REMAIN - REWIRE 6 DEDICATED STATIONS
EXISTING HVAC UNIT, SUPPLY AND RETURN TO
REMAIN
JUNCTION BOX - SURFACE
MOUNTED LIGHT FIXTURE
�84"
WALL MOUNTED LIGHT FIXTURE W/
_ •
MT'G HGT
9wr.
�
SURFACE MT'D BOX FIXTURE -
SLED
LAMP TYPE AS INDICATED
DISCONNECT
O P
SURFACE MOUNTED CL'G
PENDANT LIGHT FIXTURE
ORECESSED
CL'G LIGHT FIXTURE
ELECTRIC PANEL W/ CIRCUIT
BREAKERS (RECESSED)
ELECTRIC METER
ABBREVIATIONS:
V.P.
VAPOR PROOF
ACFI
ARC CURRENT FAULT INTERCEPT
GFI
GROUND FAULT INTERCEPT
LED
LIGHT EMITTING DIODE
ELECTRICAL PANEL
cir description pole' wire cir description pole' wire
AIR HANDLER
50.2
8
2
CONDENSER
40.2
8
3
WASHER / DRYER STACK
30.2
10
6
WATER HEATER
30.2
10
7
8
9
STATION 1 GFI
20.1
12
10
1 STATION 2 GFI
20.1
12
11
STATION 3 GFI
20.1
12
12
1 STATION 4 GFI
20.1
12
13
STATION 5 GFI
20.1
12
14
STA110N 6 GFI
20.1
12
15
LIGHTING INTERIOR
20.1
12
16
RECEPTACLE GFI
20. 1
12
17
LIGHTING INTERIOR
20.1
12
18
RECEPTACLE AFCI
20.1
12
19
j EXT. LIGHTING FRONT
20.1
12
20
ELECTRICAL CALCULATION
1 148 AIR CONDITIONED @ 3 W PER SQ FT x 1.25
4305
6 STATION RECEPTACLES @ 2000 W EA
12,000
12 RECEPTACLES @ 180 W EA
2,160
WATER HEATER
4,500
WASHER DRYER STACKED
6,000
28,965
FIRST 10000 W AT 100%
10,000
REMAINDER AT 50%
9,483
1 HVAC W/ 7KW HEAT STRIP
7,000
26483 W/ 240 V
1 1 1 AMPS
NOTES:
• ALL EXIST'G WIRES NOT USED REMOVE COMPLETELY TO CIRCUIT PANEL
• REUSE ABANDON CIRCUITS FOR NEW EQ USE
* ALL WIRE SHALL BE THWN (WET LOCATIONS) THHN (DRY LOCATIONS)
W1
EX
NEW
NEW
NEW
EX
EX
FUTURE WATER
HEATER
BREAK
ROOM
EXIST'G ELEC
PANEL
NEW INFILL WALL,
FLUSH ONE SIDE -
SHLF THE OHER
7
1 1 /2" DRAIN
AND VENT
VIP ROOM
RECEPTION
EXIST'G EXT LIGHT
AND SWITCH
REMAIN
4" DIA SIDE WALL
DRYER VENT
EXIST'G
C.O.
1 1 /2" DRAIN
AND VENT
TO OPEN
PUBLIC RO
1E :1
KL 3'-0
SHAMPOO STATION
STATION
5
BOOTHr----------------------
NEW NO —
BRG WD:;
FRAME ALL
SEE 1—A2
/REMOVE NON BR'G
/
NEW WALL AND OPNG
/
3 X 6'8 SC / HEADER
WD DR
/ I
BM ABOV
/
- --------
CH / STATION 4
` REPLACE SINKS
W/ ADA SINK' /
SEE 3—A2 , I /
-- NEW INFILL WALL, I I /
FLUSH ONE SIDE — /
WH 5�_ 7FTHEOTHER
/ # 3
----------------------
STATION 6 h I /
/ L-"y-----STATLON 3-
LO
-
VA
I /
.# 6
/
3'-011 SAWCUT CMU FOR-0/ STATION -2 - - -
3' CLEAR OPN'G
/ #2"
---------------------
II I
/ II
r- - - - - - - - - - -
TYP. SALON
CHAIR AND SHELF
I ' I
I Y I I
STATION 1
N �
co
2" RAIN
HAIR SALON
NOTE:
ALL WALLS, WINDOWS, AND DOORS EXIST UNO.
NO EXTERIOR IMPROVEMENTS OR STRUCTURAL CHANGES
EXIST'G HC ( 1 :12 ) SLOPE W/ HANDRAILS
TO OPEN
PUBLIC ROW
� F I o o r Plan RECEIVED
SCALE: 1/2" = 1'-0" p 1019
HGT S
P® �ktL� ��cqu tl•,nt
0
w
LU
w
LU
w
x
LD
J
J
Q
rn
0
N
1)
D-
o
i
14E
4—
I°
U
00
W
H
E
•a
>7C)
O
LM
O
L
o
O
6
VJ
N
�°
t
�Z
N
O
cn
LU
JOB #
DATE 9/ 16 /19
SHEET
Al
DIVISIONONE-GENERALREQUIREMENTS
Interpretation of plans - the Architects services do not include supeNision of
ACCESSIBLE BATHS
construction. The Architect divests himself of the responsibility of the work, errors or
-Access route to bathroom, door to l
emissions resulting from the interpretation of the plans. If the contractor believes
bathroom and hardware to bathroom
he has discovered errors or omissions in the plans, the contractor shall notify the
door to be accessible. Threshold to be
Architect in writing for clarification before continuing work. i
maximum 1/2" high. Door closer to 5 LB
1-2
Applicable Standards - All work under this contract, or Sub -contracts shall
pressure maximum,
conform the recent edition of local, state and national codes, ordinances and
• Provide clear floor spacer of 60"
regulations pertaining to the work, F.B.C., A.C.I., A.N.S.I, A.S.T.M., O.S.H.A., eta.
diameter circle or a "T" shaped space,
1-3
Scope or Work— Contractor shall furnish or provide for all items, articles, materials,
60" square with 36" legs. The clear space
at fixtures and controls, the accessible
operations or methods listed, mentioned or scheduled on drawings and/or herein
route and the turning space may overlap.
specified, including all labor, materials, equipment, and incidentals necessary and
required to perform and complete work as shown in drawings and/or herein
• Water closets shall be located 18" from
specified or as required for a completed project.
side wall or partition. The height of the
II
1-4
The drawings were design per FBC 2017
toilet seat shall be 17" to 19".
Wind Importance factor (Risk category) - 2
-Provide two grab bars able of restraining
1-5
Verifying Conditions - Before commencing work, Contractor shall verify
300 lb. load. Side wall: 42" long minimum,
measurement and conditions of building site. Any difference between actual
12" from back wall Back wall: 36" long
measurements and those shown on drawings shall be submitted to the Architect
minimum, centered on toilet,.. Grab bars
in writing before proceeding
to be 33" to 36" above finished floor.
1-6
Conflict of Information - if information is contradictory with different instructions for
-Flush control to be 44" high maximum, o
the some aspect, contractor must report to architect. One information must not
side of toilet.
-i
be used as more important as the other, the architect will review and revise for the
correct information.
• Dispensers: toilet paper dispensers shall
b
Z
be on the side wall below the grab bar
12
1-7
Demolition - Contractor to provide shoring for existing structure during
and a maximum of 19" high and 36" from
b
construction. Cuts and patching shall be kept to a minimum and preserve the
the rear wall. Dispensers shall provide
_;
existing finishes as much as possible. Patching locations shall use discretion to cut
continuous paper flow.
in less visible areas instead of highly visible when the work is complete.
• Urinals shall be stall -type or wall -hung
DIVISION
THREE - CONCRETE
with an elongated rim and 17" maximum
high. Urinals shall have a clear space of
3-1
Concrete - Existing concrete slab shall be a minimum strength of 3000 psi and 5"
30" wide by 48" deep minimum. Flush
with temperature steel. All concrete shall be ready mixed and in
thick p
I be 44" high, .maximum force
control shall g ,
accordance with ASTM C-94. Maximum allowable slump to be 5".
of 5 lb on flush control.
DIVISION
FIVE - METALS
•Lavatories shall extend 17" minimum
from wall. Clearance of 29" minimum sha
I
5-1
Miscellaneous Metals - Contractor shall furnish and install, or furnish for other trades
be provided from finish floor to bottom of
when required, all miscellaneous metal, steel, and metal fabrications including,
apron. knee clearance of27" minimum
but not limited to, hangers, anchors, bolts, plates, supports, lintels, brackets, and
shall extend 8" minimum under the edge
other miscellaneous items necessary to frame or support the Work.
of the lavatory. Toe clearance of 9" shall
be provided for the full length of the
5-2
Coordinate Metals - Metals in contact with each other must be selected to avoid
lavatory. A clear floor space of 30" by 48"
dielectric decomposition or supply adequate separating material between the
shall be provided in front of the lavatory.
two different metals. Metals/fasteners exposed to weather shall be stainless steel
The clear floor space shall adjoin or
unless noted otherwise on the drawings.
overlap an accessible route and shall
extend a maximum of 19" underneath the
lavatory. Hot water and drain pipes shall
b
DIVISION SIX - WOOD AND PLASTICS
be insulated. There shall be no sharp or
co
`O
6-1
Lumber - All lumber permanently incorporated into the structure shall be air or kiln -
abrasive surfaces under lavatories.
dried and shall contain not more than 19% moisture. All lumber and plywood shall
-Sink shall be mounted with rim surface n
be identified by grade stamps.
1. Min allowable flexural ending stress for beams shall be 1500 psi at normal load
higher than 34" provide knee clearance
wood shall be # 1 grade Douglas fir or better.
ration structural9 9 duration,
of 27" high, 30" wide and 19" deep
minimum.Provide other clearances
62
Furring shall be 22 o steel hat channel or 1 X pressure treated wood installed as
g g
insulation as per lavatories..
required using shims, if necessary, to provide a true planer surface for finish
-Faucets shall be operable with one hand
mate als.
with a force no greater than 5 lb.
6-3
Wood in direct contact with concrete, masonry, or soil shall be pressure treated
with the requirements of the standards of the American Wood Preservers
-Mirrors shall be mounted with bottom
Association.
edge 40" high maximum. all other
Alkaline copper (AC Q-C/D) or Copper Azole (CBA-A or CA-B) shall be used for
dispensers shall have Controls at 48" high
exteriro applications,
maximum.
- X-1 Metal fastener materials ,�
Standard (G-901 Create a s maay`De usezY 6r,treated. Chromarea COppP +ew.�.
: 4 15.1 Drinking fountains or water
1 y coolers
required to be accessible b 4.1 shall
Arsenate (CCA-C), or Sodium Borate (SBX) treated wood only.
-",' comply with 4.15.
4.15.2* Spout Height. Spouts shall be no
DIVISION NINE - FINISHES
higher than 36", measured from the floor
or ground surfaces to the spout outlet.
9-2
Gypsum Wallboard w
1. Work shall be done in strict accordance with the standards established in the
U.S.G. Drywall Construction Handbook, latest edition, or comparable publication by
other manufacturer, particularly in regard to fastener spacing and treotment of
oints ancorners
2. Fasten wallboard with 1-1/4" type W bugle head screws. Space screws 4" OC at
perimeter and 8" OC in the field on 24" OC framing min.
DIVISION FIFTEEN - MECHANICAL
tenant.
- II HVA is provided b the landlord and unchanged demands from new I
I 1 A C 5 Y p
I
15-2 Plumbing where
1. Provide plumbing system, complete in place, tested and approved,
shown on the Drawings, as specified herein, and as needed for a complete and
proper job. Existing plumbing lines may be used after inspection of installation is
correct and flow adequate to existing septic system.
2. All plumbing work and materials shall be in accordan
ce with the latest edition of the
Standard Pl
umbing
n Cod
e, loc
al ordinances and in compliance
liance with the Energy
Conservation Code.
4. Fixtures shall be protected against water hammer with air chambers when required.
5. Provide shut off Valves to all mains entering the building and each piece of
equipment.
6. Install dielectric union at inlet and outlet of water heater. Install water heater in
approved pan and provide drain line as required.
7. Building sewers, vents, and all underground drainage lines shall be schedule 40 PVC.
8. Water piping to be soft Type L. Copper, under slab, Pex above slab.
9. Water service is existing.
10. Insulation -Provide pipe insulation on refrigerant lines and domestic water lines
weather shall be protected as
Insulation exposed to p
as per Indust standards. p
p industry
required.
I I .Gather vents in attic as allowed and vent toward rear of house.
6-3 Wood in direct contact with concrete, masonry, or soil shall be pressure treated
with the requirements of the standards of the American Wood Preservers
Association.
Alkaline copper (AC Q-C/D) or Copper Azole (CBA-A or CA-B) shall be used for
extedro applications.
6-11 Metal fastener materials
Standard (G-90) treated metals may be used untreated. Chromated Copper
Arsenate (CCA-C), or Sodium Borate (SBX) treated wood only.
DIVISION SIXTEEN - ELECTRICAL
16-1 Scope: Furnish all equipment and materials and perform all labor and services
necessary to installation for a complete system for lighting and power. Each system
shall be complete in all respects and shall be turned over to Owner in a first-class
operating condition and fully tested and complete with all devices which are
normal for intended systems and those required for their safe operation.
16-2 Materials and manner of installation of electrical system shall be in strict
accordance with the requirements of the local governing authorities having
jurisdiction, and the standards set forth by NFPA, NEC, U.L., or other recognized
testing laboratories. The installation shall conform to the latest edition of the NEC
and FBC,. -
16-7 Panel Schedule: Panel shall be clearly marked as to all circuits.
16-9 All wiring shall be THWN or THHN dry locaton copper.
16-12 General duty receptacles shall be 20 amp specification grade, 125 volt AC, NEMA
5-20 configuration. white.
16-13 Panel Schedule: Panel shall be clearly marked as to all circuits.
16-14 All receptacles shall be arc -fault circuit interrupter type or gfci as required per 2008
NEC 210.12 and provided on similar circuit branch
16-15 All receptacles shall be tamper -resistant receptacles
16-16 Switches shall be specification grade 125-277 volt 20 amp. White, rocker.
16-18 Cover plates shall be hard plastic white or as directed by owner
16-19 Provide junction boxes as required and feed all lighting circuits through appropriate
junction boxes.
CL'G W/ SOUND INSUL
--WALLS W/ SOUND INSUL
NOTE:
5/8" M.R.
PROVIDE
GYPBD
TEMPER
VALVE AT
HOT WATER
C.T.
LAV
i MIRROR
3'-0"Xl 1/2" DIA.
GRAB BAR
TP
MIN
INSULATE
WATER PIPE
Z
rn
SEE FLOOR PLAN FOR
ACTUAL SIZES
DIMENSIONS ARE CLEAR SPACE
AND MINIMUM U.N.O.
EXIST'G SUSPENDED
ACOUSTICAL CLG TO REMAIN
EXIST'G AC SUPPLY AND RETURN
TO REMAIN
EXIST'G 2' X 4' LIGHT / SWITCH TO
REMAIN U.N.O.
LEGEND
NL NIGHT LIGHT
ZRETURN
ZSUPPLY
EMERGENCY LIGHT
EXIT SIGN
INT
EX
0
NNo
U
TOP PLATE TO FASTEN
<
TO TRUSS OR 2X4
BLK'G 24"OC AS
NECESSARY
U
G
u
a
m
INT
1/2" GYPBD
`g
2 x 4 WD STUDS 24" O.C.
a
NAIL TOP & BOTT PLATES AT
o
7" OC STAGGER ALL JOINTS
`o
24" MIN
"
1 /2" GYPBD
4)
2 X 4 BK'G AT 1/2 SPAN
2 X 4 P.T. PLATE W/ 1/4' DIA X 3
1/4" MAS SCREW AND WASHER
@24'OC
O
0
c
EXIST'G CONIC. SLAB
,
U
N
U
TYP NON -BEARING WALL
GYP CLG
Reflected Ceiling Plan
NL
EX
e
a
IF
U
J
N
/
s_
IL
U
.J
F�
00
.�
a
E/
'Ta
W
i
O
r
o
0)
U_
E
L
�
}
c
U
N
�
J
a
3
0
V)
r
4-
F-
Z
V,
Lu
w
w
L
w
w
r-
cD JOB #
DATE 9/ 16 /19
Q
SHEET
0
ry
A2
-C
T
Q_
O
0