HomeMy WebLinkAboutBuilding PlansBusiness - Hair Solan BUSINESS - 1 148 SQ FT. / 100 = 12 PERSONS OCCUPANCY CAPACITY: TOTAL 12 MAX. TRAVEL DISTANCE: 24FT ( 100 FEET ALLOWABLE) PLUMBING FIXT REQ : W/M 1 ( 1 PER 50 UNI - SEX) NUMBER OF EXITS REQ : 1 OCCUP. LESS THAN 49 EGRESS TRAVEL LESS 100 NUMBER OF EXITS PROVIDED: 2 � k e ELECTRICAL LEGEND DUPLEX RECPT. 12" A.F.F. �42" DUPLEX RECPT. OTHER HGT. REF. DEDICATED RECPT. -..� QUADRAPLEX RECPT GROUND FAULT INTERUPTED noG.F.I. RECPT. 220V RECPT EX NEW NEW NEW NEW EX EX EX -E�'}- SINGLE POLE SWITCH -Ela co THREE WAY SWITCH - Ek? - Q DIMMER SWITCH INTERNET JACK SD SMOKE DETECTOR Tv TELEVISION COAXIAL CARBON MONOXIDE DETECTOR Code Data: OCCUPANCY CLASSIFICATION: BUSINESS ( B ) TYPE OF CONSTRUCTION: TYPE V-B FIRE SPRINKLE SYSTEM: NO NUMBER OF BUILDING STORIES: 1 PARTY WALL RATING: NA ALL ELECTRICAL WORK TO COMPLY AND VERIFY EXIST'G COMPLY WITH 2O14 NEC & 2017 FL BUILDING CODE EXISTING CARPET FUG TO REMAIN (EXCEPT IN TOILET - VINYL) SAP CLG TO REMAIN EXISTING ELECTRICAL POWER AND LIGHTING TO REMAIN - REWIRE 6 DEDICATED STATIONS EXISTING HVAC UNIT, SUPPLY AND RETURN TO REMAIN JUNCTION BOX - SURFACE MOUNTED LIGHT FIXTURE �84" WALL MOUNTED LIGHT FIXTURE W/ _ • MT'G HGT 9wr. � SURFACE MT'D BOX FIXTURE - SLED LAMP TYPE AS INDICATED DISCONNECT O P SURFACE MOUNTED CL'G PENDANT LIGHT FIXTURE ORECESSED CL'G LIGHT FIXTURE ELECTRIC PANEL W/ CIRCUIT BREAKERS (RECESSED) ELECTRIC METER ABBREVIATIONS: V.P. VAPOR PROOF ACFI ARC CURRENT FAULT INTERCEPT GFI GROUND FAULT INTERCEPT LED LIGHT EMITTING DIODE ELECTRICAL PANEL cir description pole' wire cir description pole' wire AIR HANDLER 50.2 8 2 CONDENSER 40.2 8 3 WASHER / DRYER STACK 30.2 10 6 WATER HEATER 30.2 10 7 8 9 STATION 1 GFI 20.1 12 10 1 STATION 2 GFI 20.1 12 11 STATION 3 GFI 20.1 12 12 1 STATION 4 GFI 20.1 12 13 STATION 5 GFI 20.1 12 14 STA110N 6 GFI 20.1 12 15 LIGHTING INTERIOR 20.1 12 16 RECEPTACLE GFI 20. 1 12 17 LIGHTING INTERIOR 20.1 12 18 RECEPTACLE AFCI 20.1 12 19 j EXT. LIGHTING FRONT 20.1 12 20 ELECTRICAL CALCULATION 1 148 AIR CONDITIONED @ 3 W PER SQ FT x 1.25 4305 6 STATION RECEPTACLES @ 2000 W EA 12,000 12 RECEPTACLES @ 180 W EA 2,160 WATER HEATER 4,500 WASHER DRYER STACKED 6,000 28,965 FIRST 10000 W AT 100% 10,000 REMAINDER AT 50% 9,483 1 HVAC W/ 7KW HEAT STRIP 7,000 26483 W/ 240 V 1 1 1 AMPS NOTES: • ALL EXIST'G WIRES NOT USED REMOVE COMPLETELY TO CIRCUIT PANEL • REUSE ABANDON CIRCUITS FOR NEW EQ USE * ALL WIRE SHALL BE THWN (WET LOCATIONS) THHN (DRY LOCATIONS) W1 EX NEW NEW NEW EX EX FUTURE WATER HEATER BREAK ROOM EXIST'G ELEC PANEL NEW INFILL WALL, FLUSH ONE SIDE - SHLF THE OHER 7 1 1 /2" DRAIN AND VENT VIP ROOM RECEPTION EXIST'G EXT LIGHT AND SWITCH REMAIN 4" DIA SIDE WALL DRYER VENT EXIST'G C.O. 1 1 /2" DRAIN AND VENT TO OPEN PUBLIC RO 1E :1 KL 3'-0 SHAMPOO STATION STATION 5 BOOTHr---------------------- NEW NO — BRG WD:; FRAME ALL SEE 1—A2 /REMOVE NON BR'G / NEW WALL AND OPNG / 3 X 6'8 SC / HEADER WD DR / I BM ABOV / - -------- CH / STATION 4 ` REPLACE SINKS W/ ADA SINK' / SEE 3—A2 , I / -- NEW INFILL WALL, I I / FLUSH ONE SIDE — / WH 5�_ 7FTHEOTHER / # 3 ---------------------- STATION 6 h I / / L-"y-----STATLON 3- LO - VA I / .# 6 / 3'-011 SAWCUT CMU FOR-0/ STATION -2 - - - 3' CLEAR OPN'G / #2" --------------------- II I / II r- - - - - - - - - - - TYP. SALON CHAIR AND SHELF I ' I I Y I I STATION 1 N � co 2" RAIN HAIR SALON NOTE: ALL WALLS, WINDOWS, AND DOORS EXIST UNO. NO EXTERIOR IMPROVEMENTS OR STRUCTURAL CHANGES EXIST'G HC ( 1 :12 ) SLOPE W/ HANDRAILS TO OPEN PUBLIC ROW � F I o o r Plan RECEIVED SCALE: 1/2" = 1'-0" p 1019 HGT S P® �ktL� ��cqu tl•,nt 0 w LU w LU w x LD J J Q rn 0 N 1) D- o i 14E 4— I° U 00 W H E •a >7C) O LM O L o O 6 VJ N �° t �Z N O cn LU JOB # DATE 9/ 16 /19 SHEET Al DIVISIONONE-GENERALREQUIREMENTS Interpretation of plans - the Architects services do not include supeNision of ACCESSIBLE BATHS construction. The Architect divests himself of the responsibility of the work, errors or -Access route to bathroom, door to l emissions resulting from the interpretation of the plans. If the contractor believes bathroom and hardware to bathroom he has discovered errors or omissions in the plans, the contractor shall notify the door to be accessible. Threshold to be Architect in writing for clarification before continuing work. i maximum 1/2" high. Door closer to 5 LB 1-2 Applicable Standards - All work under this contract, or Sub -contracts shall pressure maximum, conform the recent edition of local, state and national codes, ordinances and • Provide clear floor spacer of 60" regulations pertaining to the work, F.B.C., A.C.I., A.N.S.I, A.S.T.M., O.S.H.A., eta. diameter circle or a "T" shaped space, 1-3 Scope or Work— Contractor shall furnish or provide for all items, articles, materials, 60" square with 36" legs. The clear space at fixtures and controls, the accessible operations or methods listed, mentioned or scheduled on drawings and/or herein route and the turning space may overlap. specified, including all labor, materials, equipment, and incidentals necessary and required to perform and complete work as shown in drawings and/or herein • Water closets shall be located 18" from specified or as required for a completed project. side wall or partition. The height of the II 1-4 The drawings were design per FBC 2017 toilet seat shall be 17" to 19". Wind Importance factor (Risk category) - 2 -Provide two grab bars able of restraining 1-5 Verifying Conditions - Before commencing work, Contractor shall verify 300 lb. load. Side wall: 42" long minimum, measurement and conditions of building site. Any difference between actual 12" from back wall Back wall: 36" long measurements and those shown on drawings shall be submitted to the Architect minimum, centered on toilet,.. Grab bars in writing before proceeding to be 33" to 36" above finished floor. 1-6 Conflict of Information - if information is contradictory with different instructions for -Flush control to be 44" high maximum, o the some aspect, contractor must report to architect. One information must not side of toilet. -i be used as more important as the other, the architect will review and revise for the correct information. • Dispensers: toilet paper dispensers shall b Z be on the side wall below the grab bar 12 1-7 Demolition - Contractor to provide shoring for existing structure during and a maximum of 19" high and 36" from b construction. Cuts and patching shall be kept to a minimum and preserve the the rear wall. Dispensers shall provide _; existing finishes as much as possible. Patching locations shall use discretion to cut continuous paper flow. in less visible areas instead of highly visible when the work is complete. • Urinals shall be stall -type or wall -hung DIVISION THREE - CONCRETE with an elongated rim and 17" maximum high. Urinals shall have a clear space of 3-1 Concrete - Existing concrete slab shall be a minimum strength of 3000 psi and 5" 30" wide by 48" deep minimum. Flush with temperature steel. All concrete shall be ready mixed and in thick p I be 44" high, .maximum force control shall g , accordance with ASTM C-94. Maximum allowable slump to be 5". of 5 lb on flush control. DIVISION FIVE - METALS •Lavatories shall extend 17" minimum from wall. Clearance of 29" minimum sha I 5-1 Miscellaneous Metals - Contractor shall furnish and install, or furnish for other trades be provided from finish floor to bottom of when required, all miscellaneous metal, steel, and metal fabrications including, apron. knee clearance of27" minimum but not limited to, hangers, anchors, bolts, plates, supports, lintels, brackets, and shall extend 8" minimum under the edge other miscellaneous items necessary to frame or support the Work. of the lavatory. Toe clearance of 9" shall be provided for the full length of the 5-2 Coordinate Metals - Metals in contact with each other must be selected to avoid lavatory. A clear floor space of 30" by 48" dielectric decomposition or supply adequate separating material between the shall be provided in front of the lavatory. two different metals. Metals/fasteners exposed to weather shall be stainless steel The clear floor space shall adjoin or unless noted otherwise on the drawings. overlap an accessible route and shall extend a maximum of 19" underneath the lavatory. Hot water and drain pipes shall b DIVISION SIX - WOOD AND PLASTICS be insulated. There shall be no sharp or co `O 6-1 Lumber - All lumber permanently incorporated into the structure shall be air or kiln - abrasive surfaces under lavatories. dried and shall contain not more than 19% moisture. All lumber and plywood shall -Sink shall be mounted with rim surface n be identified by grade stamps. 1. Min allowable flexural ending stress for beams shall be 1500 psi at normal load higher than 34" provide knee clearance wood shall be # 1 grade Douglas fir or better. ration structural9 9 duration, of 27" high, 30" wide and 19" deep minimum.Provide other clearances 62 Furring shall be 22 o steel hat channel or 1 X pressure treated wood installed as g g insulation as per lavatories.. required using shims, if necessary, to provide a true planer surface for finish -Faucets shall be operable with one hand mate als. with a force no greater than 5 lb. 6-3 Wood in direct contact with concrete, masonry, or soil shall be pressure treated with the requirements of the standards of the American Wood Preservers -Mirrors shall be mounted with bottom Association. edge 40" high maximum. all other Alkaline copper (AC Q-C/D) or Copper Azole (CBA-A or CA-B) shall be used for dispensers shall have Controls at 48" high exteriro applications, maximum. - X-1 Metal fastener materials ,� Standard (G-901 Create a s maay`De usezY 6r,treated. Chromarea COppP +ew.�. : 4 15.1 Drinking fountains or water 1 y coolers required to be accessible b 4.1 shall Arsenate (CCA-C), or Sodium Borate (SBX) treated wood only. -",' comply with 4.15. 4.15.2* Spout Height. Spouts shall be no DIVISION NINE - FINISHES higher than 36", measured from the floor or ground surfaces to the spout outlet. 9-2 Gypsum Wallboard w 1. Work shall be done in strict accordance with the standards established in the U.S.G. Drywall Construction Handbook, latest edition, or comparable publication by other manufacturer, particularly in regard to fastener spacing and treotment of oints ancorners 2. Fasten wallboard with 1-1/4" type W bugle head screws. Space screws 4" OC at perimeter and 8" OC in the field on 24" OC framing min. DIVISION FIFTEEN - MECHANICAL tenant. - II HVA is provided b the landlord and unchanged demands from new I I 1 A C 5 Y p I 15-2 Plumbing where 1. Provide plumbing system, complete in place, tested and approved, shown on the Drawings, as specified herein, and as needed for a complete and proper job. Existing plumbing lines may be used after inspection of installation is correct and flow adequate to existing septic system. 2. All plumbing work and materials shall be in accordan ce with the latest edition of the Standard Pl umbing n Cod e, loc al ordinances and in compliance liance with the Energy Conservation Code. 4. Fixtures shall be protected against water hammer with air chambers when required. 5. Provide shut off Valves to all mains entering the building and each piece of equipment. 6. Install dielectric union at inlet and outlet of water heater. Install water heater in approved pan and provide drain line as required. 7. Building sewers, vents, and all underground drainage lines shall be schedule 40 PVC. 8. Water piping to be soft Type L. Copper, under slab, Pex above slab. 9. Water service is existing. 10. Insulation -Provide pipe insulation on refrigerant lines and domestic water lines weather shall be protected as Insulation exposed to p as per Indust standards. p p industry required. I I .Gather vents in attic as allowed and vent toward rear of house. 6-3 Wood in direct contact with concrete, masonry, or soil shall be pressure treated with the requirements of the standards of the American Wood Preservers Association. Alkaline copper (AC Q-C/D) or Copper Azole (CBA-A or CA-B) shall be used for extedro applications. 6-11 Metal fastener materials Standard (G-90) treated metals may be used untreated. Chromated Copper Arsenate (CCA-C), or Sodium Borate (SBX) treated wood only. DIVISION SIXTEEN - ELECTRICAL 16-1 Scope: Furnish all equipment and materials and perform all labor and services necessary to installation for a complete system for lighting and power. Each system shall be complete in all respects and shall be turned over to Owner in a first-class operating condition and fully tested and complete with all devices which are normal for intended systems and those required for their safe operation. 16-2 Materials and manner of installation of electrical system shall be in strict accordance with the requirements of the local governing authorities having jurisdiction, and the standards set forth by NFPA, NEC, U.L., or other recognized testing laboratories. The installation shall conform to the latest edition of the NEC and FBC,. - 16-7 Panel Schedule: Panel shall be clearly marked as to all circuits. 16-9 All wiring shall be THWN or THHN dry locaton copper. 16-12 General duty receptacles shall be 20 amp specification grade, 125 volt AC, NEMA 5-20 configuration. white. 16-13 Panel Schedule: Panel shall be clearly marked as to all circuits. 16-14 All receptacles shall be arc -fault circuit interrupter type or gfci as required per 2008 NEC 210.12 and provided on similar circuit branch 16-15 All receptacles shall be tamper -resistant receptacles 16-16 Switches shall be specification grade 125-277 volt 20 amp. White, rocker. 16-18 Cover plates shall be hard plastic white or as directed by owner 16-19 Provide junction boxes as required and feed all lighting circuits through appropriate junction boxes. CL'G W/ SOUND INSUL --WALLS W/ SOUND INSUL NOTE: 5/8" M.R. PROVIDE GYPBD TEMPER VALVE AT HOT WATER C.T. LAV i MIRROR 3'-0"Xl 1/2" DIA. GRAB BAR TP MIN INSULATE WATER PIPE Z rn SEE FLOOR PLAN FOR ACTUAL SIZES DIMENSIONS ARE CLEAR SPACE AND MINIMUM U.N.O. EXIST'G SUSPENDED ACOUSTICAL CLG TO REMAIN EXIST'G AC SUPPLY AND RETURN TO REMAIN EXIST'G 2' X 4' LIGHT / SWITCH TO REMAIN U.N.O. LEGEND NL NIGHT LIGHT ZRETURN ZSUPPLY EMERGENCY LIGHT EXIT SIGN INT EX 0 NNo U TOP PLATE TO FASTEN < TO TRUSS OR 2X4 BLK'G 24"OC AS NECESSARY U G u a m INT 1/2" GYPBD `g 2 x 4 WD STUDS 24" O.C. a NAIL TOP & BOTT PLATES AT o 7" OC STAGGER ALL JOINTS `o 24" MIN " 1 /2" GYPBD 4) 2 X 4 BK'G AT 1/2 SPAN 2 X 4 P.T. PLATE W/ 1/4' DIA X 3 1/4" MAS SCREW AND WASHER @24'OC O 0 c EXIST'G CONIC. SLAB , U N U TYP NON -BEARING WALL GYP CLG Reflected Ceiling Plan NL EX e a IF U J N / s_ IL U .J F� 00 .� a E/ 'Ta W i O r o 0) U_ E L � } c U N � J a 3 0 V) r 4- F- Z V, Lu w w L w w r- cD JOB # DATE 9/ 16 /19 Q SHEET 0 ry A2 -C T Q_ O 0