HomeMy WebLinkAboutTANKLESS WATER HEATER SPECS - 11-3-20Rinnai
SENSEI
■ EASE OF INSTALLATION AND
SERVICEABILITY
• Compact Design to Save Space
• Wi-Fi Technology for Remote Monitoring and Management
• Simple Gas Conversion
■ OPTIONAL ACCESSORIES
Condensate Neutralizer, ScaleCutter, Drain Down Kit,
Additional Controllers, Recess Box, Pipe Cover, Recirculation
Pump, DPS/MIS Switch, EZ Connect Cables, Control -R- W I -FI
Module, Wireless Accessories, and many more.
Visit rinnaLus for a complete list of accessories.
RESIDENTIAL
SUPER -HIGH -EFFICIENCY (CONDENSING)
TANKLESS WATER HEATER
Installation Type
External (Outdoor) Residential
• Mobile Home Certified
Applications. Manufactured (Mobile)
• Complies with South Coast
Home Certified
Model Numbers
RU199e (REU-N3237W-US)
District 14 ng/J or 20 ppm
RU180e(REU-N2934W-US)
NOx Emission Levels
RU160e(REU-N2530W-US)
RU130e R EU-N2024W-US)
Approved Gas Types
Natural and Propane
Uniform Energy Factor (UEF)
0.92
Energy Factor (EF)
RU399e, RU180e, RU160e: 0.96
(Canada)
RU130e: 095
High Altitude Approved
Up to 10,200 Ft (3,109 M)
Water Flow Control
Water Flow Sensor, Electronic Water
Control and Bypass Control
Controller
Standard: Integrated Controller
Optional: MC -195T -US, MC -100V -JUS,
BC-100V-1US, MCC-91-2US
Certifications
AHRI, ANSI Z21.10.3, CSA 4.3, and
EnergyStar*
Warranty
• Heat Exchanger: 15 years or 12,000 operation hours, whichever
occurs first
• All Other Parts and Components: 5 Years
• Reasonable Labor: 1 Year
Safety Devices
Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM
Check, Over Current - Glass Fuse, Remaining Flame (OHS) and
Automatic Frost Protection
Included with Purchase
• Tankless Water Heater
• Pressure Relief Valve and Adapter
• Isolation Valve Kit
• Integrated Controller
Additional Features
• Mobile Home Certified
• Complies with South Coast
• Ultra Low NOx
Air Quality Management
• Tankless Rack SystemTM Compatible
District 14 ng/J or 20 ppm
• 1/2 in. (13 mm) Gas Line Compatible
NOx Emission Levels
CIP ca
iy Eo®
Ur SANITATION O
CERTIFIED TO ANSI Z21.10.3 - CSA 4.3
RINNAI.US • 1-800-621-9419
SPECIFICATION
RU139e RU180e RU160e RU130e
Dimensions - w, h, d
18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm)
Minimum Gas
Consumption Btu/h
15,000
Maximum Gas
Consumption Btu/h
199,000
180,000
160,000
130,000
Flow Rate'
0.26-9.8GPM
0.26-9.0GPM
0.26-8.0GPM
0.26-6.6GPM
(Min - Max)
(1.0 - 37 L/min)
(1.0 - 34 L/min)
(1.0 - 30 L/min)
(1.0 - 24 L/min)
Max Flow Rate with
11 GPM
10 GPM
9 GPM
7 GPM
Parameter Adjustment
(42 L/min)
(38 L/min)
(34 L/min)
(26 L/min)
Weight
64 Ib (29 kg)
64 Ib (29 kg)
62 Ib (28 kg)
62 Ib (28 kg)
Sound Level
53 dB
52 dB
52 dB
52 dB
Normal
81 W
62 W
1 49 W
36 W
o
Standby
1.3 W
Freeze Protection
152 W
0)
Zi
Max Current
4 Amps
Fuse
10 Amps
• Minimum: 98" F (37' C) Default
Temperature
• Maximum: 120° F (49° C) Default
140° F (60° C) With Parameter Adjustment
By -Pass Flow Control
Electronic
Gas Supply Pressure
• Natural: 3.5 in. w.c. - 10.5 in. w.c.
• Propane: 8.0 in. w.c. -13.5 in. w.c.
Ignition System
Direct Electronic Ignition
Electronic Connections
• Appliance: AC 120 Volts, 60Hz.
• Temperature Controller: DC 12 Volts (Digital)
Water Supply Pressure
• Minimum: 50 PSI (Recommended 60-80 PSI for max performance)
• Maximum: 150 PSI
Controller Cable
Non -Polarized Two Core Cable (Minimum 22 AWG)
• Gas Supply: 3/4 in. (19 mm) NPT
Service Connections
• Cold Water Inlet: 3/4 in. (19 mm) NPT
• Hot Water Outlet: 3/4 in. (19 mm) NPT
• Condensate Drain: 1/2 in. (13 mm) NPT
• Top: 2 in. (51 mm)* • Back: 0 in.
Clearances
• Bottom/Ground: 12 in. (305 mm) • Sides: 2 in. (51 mm)***
• Front: 0 in.** • Front Exhaust: 24 in. (610 mm)
' 0 in. from vent components
" Clearance for servicing is 24 in. (610 mm) in front of water heater
*** Add 0.25 in. (6.35 mm) for recess box
' Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
Minimum activation flow is 0.4 GPM (1.5 L/min).
2 The maximum gas supply pressure must not exceed the value specified by the manufacturer.
Flow curves apply only to incoming water temperatures of 70" F (21' C) or less.
For incoming water temperatures greater than 70° F (21° C), please contact Rinnai.
1 SIDE
6.50
(165)
18.50__
(470)
in. (mm)
co
12.0
(305)
62
B 1 6.16
T
GAS
E 3.57
91
Cq
( i
E
I
PRV
G 10.391
264
i t
193
i
tV
11.45
(290)
BOTTOM
0 25 50 75 100 125 150
Rinnai America Corporation - 103 International Drive, Peachtree City, GA 30269 - 1-500-621-9419 - rinnai.us
02017 Rinnai America Corporation. Rinnai America Corporation continually updates materials, and as such, content is subject to change without notice.
Local, state, provincial, feeeral and national fuel gas codes must be adhered to prior to and upon installation.
f
F - --1
G --�
- H
COLD F 9.54 242
C 3.56 90
HOT
H
62
B 1 6.16
156
GAS
E 3.57
91
D 2.78
71
PRV
G 10.391
264
A 7.60 1
193
RUe-SP-1
Sensei Residential Outdoor Spec Sheet