Loading...
HomeMy WebLinkAboutTANKLESS WATER HEATER SPECS - 11-3-20Rinnai SENSEI ■ EASE OF INSTALLATION AND SERVICEABILITY • Compact Design to Save Space • Wi-Fi Technology for Remote Monitoring and Management • Simple Gas Conversion ■ OPTIONAL ACCESSORIES Condensate Neutralizer, ScaleCutter, Drain Down Kit, Additional Controllers, Recess Box, Pipe Cover, Recirculation Pump, DPS/MIS Switch, EZ Connect Cables, Control -R- W I -FI Module, Wireless Accessories, and many more. Visit rinnaLus for a complete list of accessories. RESIDENTIAL SUPER -HIGH -EFFICIENCY (CONDENSING) TANKLESS WATER HEATER Installation Type External (Outdoor) Residential • Mobile Home Certified Applications. Manufactured (Mobile) • Complies with South Coast Home Certified Model Numbers RU199e (REU-N3237W-US) District 14 ng/J or 20 ppm RU180e(REU-N2934W-US) NOx Emission Levels RU160e(REU-N2530W-US) RU130e R EU-N2024W-US) Approved Gas Types Natural and Propane Uniform Energy Factor (UEF) 0.92 Energy Factor (EF) RU399e, RU180e, RU160e: 0.96 (Canada) RU130e: 095 High Altitude Approved Up to 10,200 Ft (3,109 M) Water Flow Control Water Flow Sensor, Electronic Water Control and Bypass Control Controller Standard: Integrated Controller Optional: MC -195T -US, MC -100V -JUS, BC-100V-1US, MCC-91-2US Certifications AHRI, ANSI Z21.10.3, CSA 4.3, and EnergyStar* Warranty • Heat Exchanger: 15 years or 12,000 operation hours, whichever occurs first • All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Included with Purchase • Tankless Water Heater • Pressure Relief Valve and Adapter • Isolation Valve Kit • Integrated Controller Additional Features • Mobile Home Certified • Complies with South Coast • Ultra Low NOx Air Quality Management • Tankless Rack SystemTM Compatible District 14 ng/J or 20 ppm • 1/2 in. (13 mm) Gas Line Compatible NOx Emission Levels CIP ca iy Eo® Ur SANITATION O CERTIFIED TO ANSI Z21.10.3 - CSA 4.3 RINNAI.US • 1-800-621-9419 SPECIFICATION RU139e RU180e RU160e RU130e Dimensions - w, h, d 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm) Minimum Gas Consumption Btu/h 15,000 Maximum Gas Consumption Btu/h 199,000 180,000 160,000 130,000 Flow Rate' 0.26-9.8GPM 0.26-9.0GPM 0.26-8.0GPM 0.26-6.6GPM (Min - Max) (1.0 - 37 L/min) (1.0 - 34 L/min) (1.0 - 30 L/min) (1.0 - 24 L/min) Max Flow Rate with 11 GPM 10 GPM 9 GPM 7 GPM Parameter Adjustment (42 L/min) (38 L/min) (34 L/min) (26 L/min) Weight 64 Ib (29 kg) 64 Ib (29 kg) 62 Ib (28 kg) 62 Ib (28 kg) Sound Level 53 dB 52 dB 52 dB 52 dB Normal 81 W 62 W 1 49 W 36 W o Standby 1.3 W Freeze Protection 152 W 0) Zi Max Current 4 Amps Fuse 10 Amps • Minimum: 98" F (37' C) Default Temperature • Maximum: 120° F (49° C) Default 140° F (60° C) With Parameter Adjustment By -Pass Flow Control Electronic Gas Supply Pressure • Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. -13.5 in. w.c. Ignition System Direct Electronic Ignition Electronic Connections • Appliance: AC 120 Volts, 60Hz. • Temperature Controller: DC 12 Volts (Digital) Water Supply Pressure • Minimum: 50 PSI (Recommended 60-80 PSI for max performance) • Maximum: 150 PSI Controller Cable Non -Polarized Two Core Cable (Minimum 22 AWG) • Gas Supply: 3/4 in. (19 mm) NPT Service Connections • Cold Water Inlet: 3/4 in. (19 mm) NPT • Hot Water Outlet: 3/4 in. (19 mm) NPT • Condensate Drain: 1/2 in. (13 mm) NPT • Top: 2 in. (51 mm)* • Back: 0 in. Clearances • Bottom/Ground: 12 in. (305 mm) • Sides: 2 in. (51 mm)*** • Front: 0 in.** • Front Exhaust: 24 in. (610 mm) ' 0 in. from vent components " Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box ' Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). 2 The maximum gas supply pressure must not exceed the value specified by the manufacturer. Flow curves apply only to incoming water temperatures of 70" F (21' C) or less. For incoming water temperatures greater than 70° F (21° C), please contact Rinnai. 1 SIDE 6.50 (165) 18.50__ (470) in. (mm) co 12.0 (305) 62 B 1 6.16 T GAS E 3.57 91 Cq ( i E I PRV G 10.391 264 i t 193 i tV 11.45 (290) BOTTOM 0 25 50 75 100 125 150 Rinnai America Corporation - 103 International Drive, Peachtree City, GA 30269 - 1-500-621-9419 - rinnai.us 02017 Rinnai America Corporation. Rinnai America Corporation continually updates materials, and as such, content is subject to change without notice. Local, state, provincial, feeeral and national fuel gas codes must be adhered to prior to and upon installation. f F - --1 G --� - H COLD F 9.54 242 C 3.56 90 HOT H 62 B 1 6.16 156 GAS E 3.57 91 D 2.78 71 PRV G 10.391 264 A 7.60 1 193 RUe-SP-1 Sensei Residential Outdoor Spec Sheet