Loading...
HomeMy WebLinkAboutReineke_Permit_DrawingsJob: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:1 of 12 CGC1520585 Existing Layout Reineke 8600 S. Ocean Drive (LPH-1) Jensen Beach, FL 34957 All work to conform to FBC 2017 6th Edition Reineke October 13, 2020 Nathan Cooke Cooke Construction, Inc. Renovation Division Firewall Guest Bath See Page 12 for Firewall Detail Half Bath Master Bath Kitchen Laundry Room Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:2 of 12Jensen Beach, FL 34957 8600 S. Ocean Drive (LPH-1) CGC1520585 Reineke October 13, 2020 Kitchen (Electrical)Reineke All work to conform to FBC 2017 6th Edition Nathan Cooke Cooke Construction, Inc. Renovation Division S S S Sink GFIGFI S S GFI Kitchen Recess LED Lights Ceiling Light 3 Recess LED Lights 3 GFI GFI GFI U/C LED Lights Cabinet Interior LED Lights U/C LED Lights 3 Gang S3 = Recess LED S = LED Interior Cabinet Lights S = U/C LED Lights 2 Gang S3 -Recess LED S = Ceiling Light NOTES Install New Light Fixtures All Appliances Remain in Same Locations Check GFI Outlets [Update if Necessary to Code] GFI Recess LED Lights Cooktop Micro/Wall Oven REF D/W Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:3 of 12Jensen Beach, FL 34957 CGC1520585 Reineke Cooke Construction, Inc.Kitchen (Floorplan/Elevations) All work to conform to FBC 2017 6th Edition Reineke October 13, 2020 8600 S. Ocean Drive (LPH-1)Nathan Cooke Renovation Division Kitchen Sink Cooktop D/W Micro/Wall Oven REF 36" Entry 44" Entry Kitchen * Enlarge Pass-Thru Opening * Install New Recess LED Lights * Install New Sink Shut-Off Valves * Relocate Electrical To Code As Needed * Install New Ceiling Light (Same Location) * Plumb New Sink & Faucet * Install New LED Interior Cabinet Lights * Install New LED Under Cabinet Lights A A B B C C D D E E Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:4 of 12 All work to conform to FBC 2017 6th Edition Jensen Beach, FL 34957 CGC1520585 Reineke October 13, 2020 8600 S. Ocean Drive (LPH-1)Nathan Cooke Cooke Construction, Inc.Master Bath (Electrical)Reineke Renovation Division GF I GFI Firewall NOTE No Wall Relocation/No Attachment To Existing Post Tension Slab See Page 12 for Firewall Detail See Page 12 for Firewall Detail S S S S S S Exhaust Fan 6 Gang S = Recess LED (Damp Rated) -Main S = Vanity Lights (Damp Rate) S = Ceiling Light S = Lighted Vanity Mirror S = Recess LED (Damp Rated) -Shower/Tub Area S = LED Under Cabinet Lights 2 Gang S = Exhaust Fan (Damp Rated) -Toilet Area S = Exhaust Fan (Dapet Rated) -Shower/Tub Area NOTES Install New Light Fixtures as Shown Install New Exhaust Fans (Same Locations) Check GFI Outlets [Update if Necessary to Code] Relocate Electrical To Code As Needed S S Exhaust FanRecess LED (Damp Rated) Lighted Mirror Vanity Light Ceiling Light GF I Master Bath Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:5 of 12Jensen Beach, FL 34957 CGC1520585 Reineke October 13, 2020 8600 S. Ocean Drive (LPH-1)Nathan Cooke All work to conform to FBC 2017 6th Edition Cooke Construction, Inc.Master Bath (Floorplan/Elevations)Reineke Renovation Division Shower Enclosure (Safety Glass) Master Bath * Install New Shower Valve * Install New Tub and Tub Valve (Drain Remains in Same Location) * Install New Wedi Shower Pan & Wall Panels (Drain Remains in Same Location) * Install Sink Shut-Off Valves * Plumb New Sinks & Faucets (Same Location) * Install New Toilet (Same Location) * Install New Shower Enclosure (w/ Safety Glass) Shower (Drain Same Location) Toilet Sink NOTE No Wall No Attachment To Existing Post Tension Slab See Page 12 for Firewall Detail Firewall Master Bath Tub (Drain Same Location) Sink Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:6 of 12 CGC1520585 Reineke October 13, 2020 8600 S. Ocean Drive (LPH-1)Nathan Cooke All work to conform to FBC 2017 6th Edition Cooke Construction, Inc.Guest Bath (Electrical)Reineke Renovation Division Jensen Beach, FL 34957 4 Gang S3 = Recess LED (Damp Rated) -Main S = Lighted Vanity Mirror S = Recess LED (Damp Rated) -Shower Area S = Exhaust Fan (Damp Rated) Single S3 = Recess LED (Damp Rated) -Main NOTES Install New Light Fixtures as Shown Install New Exhaust Fan (Same Locations) Check GFI Outlets [Update if Necessary to Code] Relocate Electrical To Code As Needed GFI S S S S S Guest BathExhaust Fan Lighted Vanity Mirror 3 3 Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:7 of 12 Renovation Division CGC1520585 Reineke October 13, 2020 All work to conform to FBC 2017 6th Edition Cooke Construction, Inc.Guest Bath (Floorplan/Elevations)Reineke 8600 S. Ocean Drive (LPH-1)Nathan Cooke Jensen Beach, FL 34957 NOTE No Wall Relocation/No Attachment To Existing Post Tension Slab A A Guest Bath Guest Bath * Install New Shower Valve * Covert Tub To Shower (Drain Remains in Same Location) * Install New Wedi Shower Pan & Wall Panels (Drain Remains in Same Location) * Install Sink Shut-Off Valves * Plumb New Sink & Faucet (Same Location) * Install New Toilet (Same Location) * Install New Shower Enclosure (w/ Safety Glass) Shower Enclosure (Safety Glass) Toilet Sink Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:8 of 12 Renovation Division CGC1520585 Reineke October 13, 2020 All work to conform to FBC 2017 6th Edition Cooke Construction, Inc.Half Bath (Electrical)Reineke 8600 S. Ocean Drive (LPH-1)Nathan Cooke Jensen Beach, FL 34957 Half Bath 3 Gang S = Recess LED (Damp Rated) -Main S = Vanity Light S = Exhaust Fan (Damp Rated) NOTES Install New Light Fixtures as Shown Install New Exhaust Fan (Same Locations) Check GFI Outlets [Update if Necessary to Code] Relocate Electrical To Code As Needed S S S GFI Va n i t y L i g h t ( D a m p R a t e d ) Exhaust Fan (Damp Rated) Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:9 of 12 Renovation Division CGC1520585 Reineke October 13, 2020 All work to conform to FBC 2017 6th Edition Cooke Construction, Inc.Half Bath (Floorplan/Elevations)Reineke 8600 S. Ocean Drive (LPH-1)Nathan Cooke Jensen Beach, FL 34957 Half Bath Half Bath * Install Sink Shut-Off Valves * Plumb New Sink & Faucet (Same Location) * Install New Toilet (Same Location) A A Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:10 of 12 Renovation Division CGC1520585 Reineke October 13, 2020 All work to conform to FBC 2017 6th Edition Cooke Construction, Inc.Laundry Room (Electrical)Reineke 8600 S. Ocean Drive (LPH-1)Nathan Cooke Jensen Beach, FL 34957 Single S = Ceiling Light NOTES Install New Light Fixture as Shown Check GFI Outlets [Update if Necessary to Code] Relocate Electrical To Code As NeededS GFI See Page 12 for Firewall Detail Firewall Ceiling Light Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:11 of 12 8600 S. Ocean Drive (LPH-1)Nathan Cooke Jensen Beach, FL 34957 Renovation Division CGC1520585 Reineke October 13, 2020 All work to conform to FBC 2017 6th Edition Cooke Construction, Inc.Laundry Room (Floorplan/Elevations)Reineke A A B B Laundry Room * Install Sink Shut-Off Valves * Plumb New Sink & Faucet (Same Location) Firewall 27"Washer 27" Dryer See Page 12 for Firewall Detail Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:12 of 12 8600 S. Ocean Drive (LPH-1)Nathan Cooke Jensen Beach, FL 34957 All work to conform to FBC 2017 6th Edition Cooke Construction, Inc.Firewall Detail Reineke Renovation Division CGC1520585 Reineke October 13, 2020 Firewall Detail NOTE: There is no plan to penetrate a rated wall assembly but if needed, see detail abv. or match existing.