Loading...
HomeMy WebLinkAboutAPPROVED Design Pressures Florida Window & Door Co. 1 125 N.Dixie Hwy Tel.(561)848-4900 LakeWorth, FL 33460 Floridawindowanddoor.com Property Information Building Information Owner: Marcie Brown Wind Zone: 160 MPH. Address: 5003 El Nueva Avenue Exposure Category: C Fort Pierce,FL 34946 Minimum Building Dimension: 15 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 35 80 7 32.0 -34.9 2 Int 74 58 7 31.1 -33.9 3 Int 74 58 7 31.1 -33.9 4 Int 74 46 7 31.6 -34.4 5 Int 74 46 7 31.6 -34.4 6 Int 44 72 7 31.8 -34.6 7 Int 36 72 7 32.2 -35.0 8 Int 36 72 7 32.2 -35.0 9 Int 44 72 7 31.8 -34.6 10 Int 53 76 7 31.2 -34.1 11 Int 76 53 7 31.2 -34.1 12 Int 36 24 7 33.5 -36.3 13 Int 36 24 7 33.5 -36.3 14 Int 36 24 7 33.5 -36.3 15 Int 74 50 7 31.4 -34.3 16 Int 52 50 7 32.2 -35.0 17 Int 74 46 7 31.6 -34.4 18 Int 37 50 7 32.9 -35.8 19 Int 37 77 7 32.0 -34.8 20 Int 37 77 7 32.0 -34.8 21 Int 37 77 7 32.0 -34.8 22 Int 37 73 7 32.1 -34.9 23 Int 29 71 7 32.7 -35.5 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1