Loading...
HomeMy WebLinkAboutAPPROVED Single HungFlorida Building Code Online https://www.floridabuilding.org/pr/pr_appjtl.aspx?param=wG... Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Custom Window Systems Inc. 1900 SW 44th Avenue Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Jay Lathrop jlathrop@cws.cc Jay Lathrop 1900 SW 44th Ave Ocala, FL 34474 (352) 368-6922 Ext 291 jlathrop@cws.cc Jay Lathrop 1900 SW 44th Ave. Ocala, FL 34474 (352) 368-6922 Ext291 jlathrop@cws.cc Windows Single Hung Certification Mark or Listing Keystone Certifications, Inc. Steven M. Urich, PE ,< Validation Checklist - Hardcopy Received Standard AAMA/W DMA/CSA/101/I.S.2/A440-08 ASTM E1886-05 ASTM E1996-09 PA TAS 201/202/203 Year 2008 2005 2009 1994 1 of 2 6/18/2020, 12:14 PM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wG... Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option A 01/16/2019 01/17/2019 01/22/2019 FL # Model, Number or Name Description 15699.1 SH-3100 SH-3100 (was 3700), Aluminum Single Hung, Single Glazed, Impact Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile Impact, see Installation drawings for DP and sizes. Glass complies with ASTM E1300-04. Certification Agency Certificate FLIS699 R4_C_CAC _138-1003.pdf FL15699 R4_C_CAC_138-1004.pdf FL15699 R4_C_CAC_138-1005.pdf FL15699R4_C_CAC_138-1022.pdf FL15699R4_C_CAC_138-1023.pdf FL15699R4_C_CAC_138-1024.pdf FL15699 R4_C_CAC_138-297.pdf FL15699 R4_C_CAC_138-298.pdf FL15699 R4_C_CAC _138-299.pdf Quality Assurance Contract Expiration Date 12/28/2021 Installation Instructions FL15699 R4_II CWS-726C.pdf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Evaluation Reports FL15699_R4_AE_EvalReport726C.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. S.4R)Lright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want youre-mailaddress released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be madeavailable to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 99 Credit Card Safe 2 of 2 6/18/2020, 12:14 PM URNER ENGINEERING & CONSULTING, INC. 1239 Jabara Ave. North Port, FL 34288 Ph. 941-380-1574 FBPE C.O.A. #29779 Evaluation Report 726C August 28, 2017 Product Description: Series 3100 (previously 3700) Aluminum Single Hung Window, LM Impact, max. unit sizes of 53 1/8" x 84" DP70 Oriel, 53 1/8" x 76" DP70 OX Equal Split, and 37" x 63" DP80 OX Equal Split Manufacturer: Custom Window Systems, Inc. 1900 SW 44`h Ave, Ocala, FL 34474 Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 6`h Edition (2017) Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL 2) Approval drawing CWS-726C, signed and sealed by Lucas A. Turner, P.E. 3) Test Reports NCTL-210-3795-1, -lA, -2, -2A, -3, and -3A, and NCTL-210-4000-01, -1A, - 02, and -2A from National Certified Testing Laboratories, Orlando, FL signed and sealed by Gerard J. Ferrara, P.E., and test reports CWS-004-02-02 and -03 and CWS-005-02-01 and -02 from PRI Construction Materials Technologies, Tampa, FL, with testing Performed: TAS 201/202/203 1994, AAMA/WDMA/CSA 101/I.S.2/A440-2008, ASTM E 1886-2002/2004/2005, and ASTM E 1996-2002/2004/2006/2009 4) Supplemental Calcs. to support CWS-726C, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-726C. Limitations of Use: This product: • May be used up to sizes indicated above in Product Description, with glass types, design pressures, and max. glass daylight sizes as shown in CWS-726C • Is Large Missile Impact Resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • I.G. glass with annealed outboard lite may not be used above 30 ft from grade in HVHZ • Requires Kuraray (Dupont) PVB Interlayer per Miami -Dade N.O.A. 16-1117.02t • Requires 6063-T6 aluminum extrusions per CWS-726C t I have evaluated the material in this NOA and find that it complies with the requirements of the 6`i' Ed. (2017) Florida Building Code for use in this product. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. �0' O RE W `!Ak, F_ IV Sty '���'•+s e Lucas +`';� No 88201 Turner 2017-08-30 :. '; STATE of 1�t �'.,�'; 8/28/2017 16:05+20:00 :';� o a gyp?.`! Lucas A. Turner, P.E. ���►:,s�[iNAt-��`''� FL PE #58201 0 UNIT 30 5/8" SASH SINGLE HUNG - IMPACT -53 1/8" UNIT WIDTH 50" GLASS DLO A 767 A �531/8" UNIT WIDI ---50" GLASS DLO -- - I �I-77 ----- O B 501/4„ I GLASS O GLASS DLO DLO I B I 6 76 UNIT HEIGHT I I I 38 7/8" X 34" X 25.4 SASH GLASS ' ASS HEIGHTI DLO A C 48 1/8" GLASS DLO 48 1/8" GLASS DLO 51 5/8" SASH WIDTH 1 51 5/8" SASH WIDTH ORIEL EQUAL SPLIT 37" UNIT WIDTH 33 7/8" GLASS DLO I% F1'G 2" ss 63" UNIT GENERAL NOTES & ELEVATIONS .......... 1 GLAZING DETAIL......................................2 SECTION VIEWS.......................................3 EXTRUSIONS & B.O.M ..............................4 ANCHOR SCHEDULE & NOTES...............5 INSTALLATION DETAILS, ......................... 6 IR IIII Ll IIII GLASS HE HEIGHTI DLO 27 -32" GLASS DLO -- 351/2" SASH WIDTH EQUAL SPLIT GENERAL NOTES: icom. 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WINDOW SYSTEMS WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE 1900 SW 44TH AVE. HIGH VELOCITY HURRICANE ZONE (HVHZ) AND IS RATED FOR WIND ZONE 4 OCALA, FLORIDA 34474 MISSILE LEVEL D IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC. WWW,CWS.CC 2. GLAZING DETAILS: (SEE SHEET 2) 3. CONFIGURATIONS: "O/X" 3100 ALUM. SINGLE HUNG 4. DESIGN PRESSURES: IMPACT -NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. -POSITIVE DESIGN LOADS BASED ON TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE, AND GLASS TABLES ASTM E-1300-04e01/09. F p w 0 w O d 5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED IN THE Z LU w_ic ¢�-Zw ¢ oo 3 y o o m DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR INSTALLATION DETAIL. WIND D- I- w Z 1,3 2 _ LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR Z O Z = ¢ w w O O OHOV¢=IfW CALCULATIONS. U v u) F- n. PC/) a. 6. PRODUCTS APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT Z O O � z O U - z REQUIRED. } Q� o W O� o 7. ALL FRAMES AND SASHES ARE PROCESSED AND SCREWED TOGETHER. SMALL Lu Op a } 3 O JOINT SEALANT USED AT ALL FRAME JOINTS. r Z cn a w o J tW- 8. SERIES / MODEL DESIGNATION SH-3100. (A.K.A. SH-3700) _ ~ a ww � w a h 0- 9. THE DESIGNATION XAND O STAND FOR THE FOLLOWING: X = OPERABLE SASH, 0 = FIXED SASH ,� . gDREby T r��, 10. SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS. ,`*o '.,GP5.4�G E NSF��T LucasTurne r 2017-09-22 13:22-04:00 CONFIG. MAX. UNIT SIZE DESIGN PRESSURE RATING IMPACT RATING ORIEL 53-1/8" x 84" +/- 70 PSF LARGE MISSILE IMPACT EQUAL 53-1/8" x 76" +/- 70 PSF EQUAL 1 37" x 63" +/_ 80 PSF x"7— 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 SHEET DESCRIPTION: GENERAL NOTES AND ELEVATIONS DRAWN BY: DATE: TEF 05/17/12 DWG#: REV:: CWS-726 C SCALE: SHEET 1:25 1 OF 6 5/16" OVERALL 1/8" ANNEALED .090 DUPONT PVB INTERLAYER 1/8" ANNEALED PURFECT GLAZE "H" 34 OR SIKAFLEX 552 3/4" GLASS BITE GLASS TYPE A - SASH 7/8" OVERALL 1/8" ANNEALED 7/16" AIRSPACE 5/16" LAMINATED 1/8" ANNEALED .090 DUPONT PVB INTERLAYER 1/8" ANNEALED PURFECT GLAZE "H" 34 OR SIKAFLEX 552 BITE U" QUANEX DURASEAL IG SPACER GLASS TYPE C - SASH 5/16" OVERALL 1/8" ANNEALED .090 DUPONT PVB INTERLAYER 1/8" ANNEALED 34 PURFECT GLAZE "H" OR SIKAFLEX 552 3/4" GLASS BITE GLASS TYPE A - FIXED -7/8" OVERALL -1/8" ANNEALED -7/16" AIRSPACE -5/16" LAMINATED -1/8" ANNEALED -.090 DUPONT PVB INTERLAYER - 1/8" ANNEALED 4 PURFECT GLAZE W' OR SIKAFLEX 552 3/4" GLASS BITE -U3" QUANEX DURASEAL 71 IG SPACER GLASS TYPE C - FIXED 7/1 OVERALL 3/16" ANNEALED .105 DUPONT PVB INTERLAYER 3/16" ANNEALED 34 PURFECT GLAZE"H" // wg A /)m �V- (/d+/INDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 www.cws.cc OR SIKAFLEX 552 3100 ALUM. SINGLE HUNG 3/4" GLASS BITE IMPACT 3' a ~ z 3 ¢z3 p w 0 Q FwF O w ZOZ_ w �F�H u- z I-LU ZI-�22 Z2�Q�wp0 O Oto1--Za- coa IQ o Z z—��zF�y OOUVj OU- �?wgpOwZ of W Ow OK�0 Lu Ww GLASS TYPE B- FIXED a = Lu a 0 O_ U wo _~� �cn 3: D. 1 O- D:w d -7/8" OVERALL -3/16" ANNEALED -1/4" AIRSPACE -7/16" LAMINATED -3116" ANNEALED ..105 DUPONT PVB INTERLAYER 3/16" ANNEALED 34 PURFECT GLAZE"H" OR SIKAFLEX 552 1 3/4" GLASS BITE GLASS TYPE D - FIXED QUANEX DURASEAL IG SPACER SETTING BLOCKS PER FBC 2411.3.3.1 TYPE DESIGN PRESSURE (PSF) MAX. SIZE SASH GLASS FIXED GLASS EQUAL +/- 80 37" x 63" A or C A or C +/- 70 53" x 76" A or C 1 A or C ORIEL +/- 70 53" x 84" A or C B or D 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 EET DESCRIPTION: GLAZING DETAILS AWN BY: DATE: TEF 05/17/12 IG#: REV.: CWS-726 C ALE: SHEET 1:1 2 0F 6 INTERIOR WIPIISOdV SYSTEMS 4 32 19 31 9 33 31 32 1900 SW 44TH AVE. OCALA, FLORIDA34474 WvvW.CWs.Cc 4 _ 11 3100 ALUM. SINGLE HUNG 10 or 36 or 37 1, IMPACT Q H- Z 3: ¢Z� 0Wp NLD0O WO ZOZ OR�m �ZI—i>.22 33 LL I¢—W 25 s 20 10 or 36 or 37 30 33 SECTIONB-B24 8 Z 0 U Z=0¢<wpo ¢ OwwZa wa 28 Z OZ ZU(6z 0 n ¢ F=ZI.mpOLI -Z ¢�Ow—=O— 1 - - INTERIOR w Ooxu owv�w 11�1w 0JInI- D 19 _~of ul3L�il`}" 7 7 n o quuud� TGrr4 .......... F 17 C ;'00EAl 2 No 58201 *c c*= 30 9pz STATE OF .4.0 15 irrT� �R4 O R rrrr+sslONA�� 12 33 3 24 10 X 9/22/2017 1s LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. 19 NORTH PORT, FL 34288 PH. 941-380-1574 SHEET DESCRIPTION: 35 SECTION C-C SECTION VIEWS ALT. SILL LATCH DRAWN BY: DATE: NOTE: MONOLITHIC LAM] SHOWN. IG AVAILABLE, SEE SHEET 2. TEF 05/17/12 5 30 13 DWG#: REV.: ITEMS NOT SHOWN FOR CLARITY: CWS-726 C SECTION A -A 14, 16, 18, 21, 22, 26, 27 SCALE: SHEET 1:1.33 3 OF 6 x. .270 x . .210 x . 36 1 S-1949 Or x 5/8" x 2" VENDOR MATERIAL I-23/4"� 21,16" 4 Ins" FRAME HEAD - S-1931 Keymark Aluminum Keymark Aluminum Keymark Aluminum Keymark Aluminum Keymark Aluminum Keymark Aluminum Keymark Aluminum Keymark ,re,.,.,,,,, Aluminum —._:_.. Lawrence LINE ITEMS NOT USED: I NOTE: ALUMINUM PROFILES ARE 6063-T6 UNLES OTHERWISE NOTED. 29 SASH CORNER CONSTRUCTION FRAME CORNER CONSTRUCTION 2 FIXED MTG RAIL CONSTRUCTION SMALL JOINT SEAM SEALANT USED AT ALL FRAME JOINTS 3 FRAME SILL - S-1932 2 5!8" 6 2 3/16" FRAME JAMB - S-1933 13/16" 1 1/4" 12 1/16" SILL LATCH - S-1956 2 WINDOW SYSTEMS 1 1900 SW 44TH AVE. 2 5/16" OCALA, FLORIDA 34474 W W W.CWS.CC 1/16" 7/8" 7 L 1/6" 3100 ALUM. REINFORCEMENT -S-1935 SINGLE HUNG SASH MTG RAIL - H-1946 IMPACT z 3: az� I- aw0 QwOpo o zOz O�zm_ 1v6^ u PW Zz -�i= Z z=2¢xwp0 O O�OZa H5a U Z-U-2F.Oy 9 z OU`Uc �U- IIII-r-_O-_n��_I 1I Q P - , 200u-0 2 1/2" I.JUI� 1 3/4" x ¢ O w E- H O Z F- U 1/16" 1� 1/16" w 00 LU(0 0 w rn w zLL 0 -j U) I- L0 Wr0 a0of 2r SASH SIDE RAIL- S-1939 a I=- FIXED MTG RAIL - H-1934 2 2 1/16" SASH BTM RAIL - H-1947 15/16, 9/16" 8 1/16" SCREEN ADAPTOR - S-1936 F T— 11 13/16" V 16" SASH STOP - S-1954 3/4" 1/2" 36 GLAZING BEAD, 7/16" - S-1949 3/4" 3/4" 3/1'T6 5/8" T 37 10 7/8" 1/16" 1„ 1/16„ PVC GLAZING BEAD, 7/8" IG - P-5523 GLAZING BEAD, 5/16" - S-1941 ;;—�' ;:f— 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 BOM AND EXTRUSIONS TEF 05/17/12 VG#: REV.: CWS-726 C ALE. SHEET 1:2 4 OF 6 6" MAX. (TYP.). -... 14" MAX. O.C. (TYPJ �Ltw u MLV SEE NOTE 2 WINDOW SYSTEMS III( I.I 6" MAX. (TYP.) 14" MAX. O.C. (TYP.) 6" MAX. (TYP.) 1900 SW 44TH AVE. SEE NOTE 2 — — — — — — OCALA. FLORIDA 34474 6" MAX. (TYP.) I WWW.CWS.CC 6" MAX. (TYP.) 1/2" MAX. O.C. (TYR) — — — — — — 3100 ALUM. 7712 SEE NOTE 2 / � 13 1l2" MAX, O.C. 6" MAX (TYPO — — 13 1/2' — — — — — MAX. O.C. INSTALLATION RYP.) L ANCHORS (TYP.) I SINGLE HUNG � (TM (I IMPACT 1 O INSTALLATION ANCHORS (TYP.) O Q Z ?� Q Z MAXO.C. I INSTALLATION (TYP.)O ANCHORS (TYP Z W w 0 ¢ Lu Z W W ZOZ m_—F Z Z=2<mwoo o 4" (TYP.) z 0cnI-vaPv~)a. o(D0U)ZE)5—' 4" (TYP.) 4„ (TVP.) �[ 4„ (TYP-) Q > F- Z LL 2 0 O LL Z Q 3 0 W — = 0 _ 4" (TYP.) X. ' ` P5 1 I I I (TYP.) 1 X I w 0 o�0:cn0W(nw Z= a CL p vtn ~) L m _~� W wo 1 CL a — — — — — — — — — — _ — ANCHOR LAYOUT EQUAL SPLIT 37" X 63" ANCHOR LAYOUT EQUAL SPLIT 53.125" X 76" ANCHOR LAYOUT ORIEL 53.125" X.84" NOTES: 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT, LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 6. 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 4" FOR MASONRY, 1" FOR WOOD AND METAL. 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMAANDMA 250(BOX WINDOWS), FMA/AAMA/WDMA 300(EXTERIOR DOORS) r� 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH.941-380-1574 ANCHOR SCHEDULE AND NOTES TEF 05/17/12 VG#: REV.: CWS-726 C ALE: SHEET 1:20 5 OF 6 TYPICAL HEAD ANCHORAGE INTERIOR �� MIN. EDGE DIST. _ WINDOW SYSTEMS SEE TABLE 1 1900 SW 44TH AVE. MIN. EMBEDMENT OCALA, FLORIDA 34474 SUBSTRATE BY OTHERS SEE TABLE 1 W W W.CWS.CC SEE TABLE 1 1/4" MAX. SHIM PERIMETER SEALANT MIN. EMBEDMENT 3100 ALUM. BY INSTALLER INSIDE AND OUT SEE TABLE 1 MIN.DGE DIST. SINGLpE HUNG SEALANT BEHIND FLANGE INSTALLATION ANCHOR IMPACT BYINSTALLER MAX. SHIM SEE TABLET1/4" Q Z 3 ¢Z�H- 0 w 0 U)WI-00 0' w zOzZW--SEALANT OF INTERIOR BEHIND FLANGE ATE BY OTHERS Ia. Lu Z _ BY INSTALLER SEE TABLE 1 Z O Z= 2 Q Q. W 0 p 01-0o<=FW INSTALLATION ANCHOR SEE TABLE 1 PERIMETER SEALANT O O 0 O � Z D' H to O. Z - U` Z BYINSTALLER Z Q p U = U - - INSIDE AND OUT Z O 0 L' Z 8 HORIZONTAL SECTION '< wO } j 3: O S TYPICAL JAMB ANCHORAGE W Q u- W O FW- 0 ~ 4�1/4" MAX. SHIM OL �wBYINSTALLER SEALANT BEHIND FLANGE glOR WPERIMETER SEALANTtiC BY INSTALLERMIN. EMBEDMENTINSIDE AND OUTSEE TABLE 1 S� C No 58201 SUBSTRATE BY OTHERS SEE TABLE 1 :� 13 STATE OF .'w EDIST. SEE TABLE VERTICAL SECTION TYPICAL SILL ANCHORAGE z� 9/22/2017 LUCAS A. TURNER, P.E. TABLE 1: APPROVED INSTALLATION FASTENERS SUBSTRATE TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH.941-380-1574 SHEET DESCRIPTION: INSTALLATION DETAILS DRAWN BY: DATE: TEF 05/17/12 CWS-726 C SCALE: SHEET 1:2 6OF6 CONCRETE (2.0 KSI MIN.) 3/16" ITW TAPCON 1-1/2" 1-1/8" HOLLOW OR GROUT -FILLED CMU (117.PCF MIN.) 3/16" ITW TAPCON 1" 4" CONCRETE (2.85 KSI MIN.) 3/16" ELCO ULTRACON GROUT -FILLED CMU (ASTM C-90) 3/16" ELCO ULTRACON 2-1/4" 2-1/2" 2X MIN. SOUTHERN PINE (G=0:55) 3/16" ITW TAPCON OR ELCO ULTRACON 1-3/8" 7/8" 2X MIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 1-3/8" 7/8" 16 GAUGE (0.060") MIN. STEEL STUD #10-16 HILT[ KWIK-FLEXOR ITW FULL THREAD. 7/16"