HomeMy WebLinkAboutBlower door testDate: i Contractor: Job Address: Cons 'ruction: 3 /1 o-i-, 1? Zo Plaii17114119 ir: ©evelopmenel -Services Building & Code iiegulatlon Division 2300 Virginia Ave, lam 201 iFOrt Pierce, Fl. 34982 Phone: 772-462-2165 Fam 772-462-6443 BLOWER DOOR TEST F9W6V� ""se Ora'filltMdon Test Cer�1j;katio[R Prescrup&e and tree°noirsim@lace Method Peerrnit;: Z bC>3— oSa New Construction — Complete r c ft 3 Qti C-fistino s After Aeddi'don House Infiltration Test Results CFM (50) _ �f "1 `1 SLC Climate Zone 2 Volume = I SS/ o Test Da-[ e: J I 3/ Z_J z ACF3 (Sr,,) = CFM (50) 3( GO J Volume =_ Massing results must be AC (50) or less It4echanical Ventilation ragL1it ac' less than -:,, A V?ass ( )Fail FBC, Energy I The building or dwelling unit shall be tested and verified as having an air leakage rate of not eXceedin hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted vt iths pet blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as define Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),;din approved third party. A written report of the results of the test shall be signed by the party condcting the t(estand Provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thernal envelope. FSC, ResideI Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a Pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1 the dwelling unit shall be provided with whole -house mechanical ventilation ion In ac c/ordancel/with ect oCode,nn M1507 � rva`ion i estine n� Company Name: P170-Duct Services Address: '1915 Rio Vista Drive, Ft. Pierce, FL 34949 I hereby certin/ that the above House Infiltration results demonstrate compliance with F6C Energy Conservati requirements in accordance with Section R402.4.1.2 Climate -Zone 2. on Signature; L�- Printed Name: Mai Lin I(Ieln License/Certification #: 5061633 eUN Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 772-462-2165 Fax 772-462-6443 FBC ENERGY CONSERVATION CODE Duct Sealing Certification Prescriptive and Performance Method Date: _ I I �3/�� Z 2, 0 Permit #: _ _ a Lot #: Contractor: (k JV- G- 0) 1�r N o ,� e j Address: `f- �- 0 (� h I ey p r rJ; FL P,C q S Construction: ,Post Construction Test ❑ Rough -in Test / Test Conditions: Date: 11 3� t otio Time: Indoor Temperature (F): '7 Outdoor Temperature (F): Duct Leakage: <Default ❑ Prop. Leak Free Test Pressure: 2 S (Pa) Baseline Duct Pressure (optional) () I I (Pa) Duct Press. (Pa) I Flow Testing Company Company Name: Pro -Duct Services Floor Area (ft2): Primary Location of Supply Ductwork Primary Location of Return Ductwork ❑ Proposed On = Press I Flow (cfm) I Results:ass ❑ Fail l sl a� �. rt 5-3' —1 Total Leakage (cfm): 3 1 Total Leakage per 100 sgft: 2 CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sgft. Address: 3 i 5 r ; r�ti ( ::rc : FLJ"f t = I hereby certify that the above Duct Sealing Leakage results demonstrate compliance with 5th Edition FBC Energy Conservation requirements in accordance with Section R403.2.2. Signature: Printed Name: Martin Klein License/Certificate #: 5061633 BUILDING PERFORMANCE INSTITUTE, INC. 107 Hermes Road, Suite 210 Malta, NY 12020dig�. ry (877) 274-1274 , www.bpi.org i , _ �pl Martin Klein Wsn BPI IN: 5061633 (SEE REVERSE SIDE FOR DESIGNATIONS AND EXPIRATION DATES) CERTIFIED PROFESSIONAL DESIGNATION EXPIRATION DATE Infiltration & Duct Leakage (IDL) 4,2612021 BUILDING PERFORMANCE INSTITUTE, INC.