HomeMy WebLinkAboutApproved PlansTABLE 1 BOW/RAFTER FRAA._, END POST, GROUND ANCHOR AND PA..tL FASTENER SPACING SPECIFICATIONS PRODUCT CATEGORY SUB CATEGORY MANUFACTURER APPROVAL P.O. BOX 1263 AVERAGE FASTENER SPACING DOBSON, NORTH CAROLINA 27017 No. & DATE STRUCTURAL COMPONENTS ROOF DECK ON -CENTERS ALONG RAFTERS OR FL20717.1 ENGINEERING AND TESTING, INC. 2BECHTOL G p 26 Gauge AG Panel MAXIMUM PURLINS, AND POSTS OR GIRTS STRUCTURAL WALL WIND ULTIMATE NOMINAL POST I RAFTER (INCHES) P" INTERIOR END EXPOSURE WIND SPEED WIND SPEED SPACING Series 402-14 CATEGORY (MPH) (MPH) (FEET) POSTS/RAFTERS POSTS/RAFTERS B, C, or D 115 TO 150 I 89 TO 116 1 5.0 1 6 1 6 151 TO 180 I 117 TO 139 1 4.0 1 6 1 6 NOTES: 1. Specifications applicable to 26 gauge metal panels fastened directly to 12 or 14 gauge steel tube bow frames. 2. Fasteners consist of 1/4"-14X1" self -drilling screws with control seal washer. 3. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7° to 27' (1.5:12 to 6:12 pitch). Spacing requirements for other roof heights and/or slopes may vary. APPROVED PRODUCTS LIST PRODUCT CATEGORY SUB CATEGORY MANUFACTURER APPROVAL P.O. BOX 1263 (1 DOBSON, NORTH CAROLINA 27017 No. & DATE STRUCTURAL COMPONENTS ROOF DECK CAROLINA CARPORTS, INC, FL20717.1 ENGINEERING AND TESTING, INC. 2BECHTOL G p 26 Gauge AG Panel 10/13/16 STRUCTURAL COMPONENTS STRUCTURAL WALL CAROLINA CARPORTS, INC. FL20727.1 26 Gauge AG Panel 10/13/16 EXTERIOR DOORS SWINGING ELIXIR DOOR AND METAL COMPANY FL17996.3 Series 402-14 09/07/15 EXTERIOR DOORS ROLL -UP ASTA INDUSTRIES INC. FL8888.1 Model 203 05/31/15 WINDOWS SINGLE HUNG POCAHONTAS ALUMINUM COMPANY, INC. FL12940.2 Model 100 VS 01/06/16 GENERAL NOTES: METAL CARPORT INSTALLATION PLANS AND DETAILS AND FRAMING AND FASTENER SPECIFICATIONS 1 D JAN 2 4 2,� FOR CONSTRUCTION IN THE STATE OF FLORIDA o�Yyo NO $nom CONCRETE FOUNDATION DE y�1\ T OMMENDATIONS: CONCRETE SHALL HAVE A MINIMUM & OG Op 1PRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. T COVER OVER REINFORCING STEEL 2C O FOR FOUNDATIONS, MINIMUM CONCRETE C 'EINFROCING BARS SHALL BE: 3 INCHES IN FOUNDATIONS WHERE THE CONIC O(� LP 'AGAINST AND PERMANENTLY IN CONTACT WITH THE EARTH C 'A 0 'O THE EARTH OR WEATHER AND 1-112 INCHES ELSEWHERE. �O REINFORCING STEEL: THE REINFORCING STEEL SHALL BE MINIMUM GRAD, O� �2^ GALVANIZATION: METAL ACCESSORIES FOR USE IN EXTERIOR WALL CON • G ID NOT DIRECTLY EXPOSED TO THE WEATHER SHALL BE GALVAP 2i\ !� RDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTOR: O` ITS AND NAILS EXPOSED DIRECTLY TO THE WEATHER SHALL BE ST/, 2� OR HOT DIPPED GALVANIZED. 11% Q OG� 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITi TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2. THESE STRUCTURES ARE DESIGNED AS UTILITY/STORAGE BUILDINGS CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC., SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3. ALL STEEL TUBING SHALL BE 50 KSI STEEL. 4. FASTEN METAL ROOF AND WALL PANELS TO FRAMING WITH #12-14 x 3/4" SELF DRILLING FASTENERS WITH CONTROL SEAL WASHER @ 6" O.C. AVERAGE. 5. ALL FIELD CONNECTIONS SHALL BE #12-14 x 3/4" SELF DRILLING SCREWS. 6. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED. 7. BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6" OF EACH CORNER POST AND ONE WITHIN 6" OF EVERY OTHER INTERIOR P05T LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING AND/OR CONCRETE SLAB CONSTRUCTION. 8. CONCRETE EXPANSION ANCHORS SHALL BE WEJ-IT ANKR-TI'IE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT. 9. POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS AND GABLE ENDS. 10. SLAB FOUNDATION SU13GRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FLORIDA BUILDING CODE FIFTH EDITION (2014) (FBC FE 2014) - RESIDENTIAL, AND SECTION 1816.1 OF THE FBC FE 2014 - BUILDING. CONCEALED FASTENERS OR ATTACHMENTS ARE THE pRESPO"BMYOF THE wn� 1111Y I OR OF 'I'HESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAYBE NECESSARY:IN.ORDER TO COMPLY WITH ALL APPLICABLE CODES. LApu t- n3j CT ST. LT rOUNTY RIT11 T`rNG nIVISION REVIEWED FOR CO LLL.CE REVIEWED RY DATE 7 PLANS AND PERINUT MUST BE KEPT ON JOB OR NO ENSPECT10N WILL BE BLADE. THIS IS TO CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 1609 OF THE FLORIDA BUILDING CODE, FIFTH EDITION (2014). THE PLANS ARE VALID UNTIL THE NEXT REVISION OF THE FLORIDA BUILDING CODE. BECHTOL 605 WEST NE' DELAND, FLO \\\\a 1W I1% nOF . z iii:` •'•., FLOR\0?:• �C9\� CAROLINA CARPORTS, INC. 11/30/16 BECHTOL ENGINEERING RR EX NTs AND TESTING inc. rn ucrzc»xr y m wx„ww ,wo wmws msnxo moxme ­• TB ° G16001 TB SHEET1OF4 PREPARED FOR: CAROLINA CARPORTS, INC. P.O. BOX 1263 (1 DOBSON, NORTH CAROLINA 27017 PREPARED BY. ENGINEERING AND TESTING, INC. 2BECHTOL G p 605 WEST NEW YORK AVENUE ?> DELAND, FLORIDA 32720 —� Certificate of Authorization No. 00005492 o�Yyo NO $nom CONCRETE FOUNDATION DE y�1\ T OMMENDATIONS: CONCRETE SHALL HAVE A MINIMUM & OG Op 1PRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. T COVER OVER REINFORCING STEEL 2C O FOR FOUNDATIONS, MINIMUM CONCRETE C 'EINFROCING BARS SHALL BE: 3 INCHES IN FOUNDATIONS WHERE THE CONIC O(� LP 'AGAINST AND PERMANENTLY IN CONTACT WITH THE EARTH C 'A 0 'O THE EARTH OR WEATHER AND 1-112 INCHES ELSEWHERE. �O REINFORCING STEEL: THE REINFORCING STEEL SHALL BE MINIMUM GRAD, O� �2^ GALVANIZATION: METAL ACCESSORIES FOR USE IN EXTERIOR WALL CON • G ID NOT DIRECTLY EXPOSED TO THE WEATHER SHALL BE GALVAP 2i\ !� RDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTOR: O` ITS AND NAILS EXPOSED DIRECTLY TO THE WEATHER SHALL BE ST/, 2� OR HOT DIPPED GALVANIZED. 11% Q OG� 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITi TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2. THESE STRUCTURES ARE DESIGNED AS UTILITY/STORAGE BUILDINGS CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC., SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3. ALL STEEL TUBING SHALL BE 50 KSI STEEL. 4. FASTEN METAL ROOF AND WALL PANELS TO FRAMING WITH #12-14 x 3/4" SELF DRILLING FASTENERS WITH CONTROL SEAL WASHER @ 6" O.C. AVERAGE. 5. ALL FIELD CONNECTIONS SHALL BE #12-14 x 3/4" SELF DRILLING SCREWS. 6. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED. 7. BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6" OF EACH CORNER POST AND ONE WITHIN 6" OF EVERY OTHER INTERIOR P05T LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING AND/OR CONCRETE SLAB CONSTRUCTION. 8. CONCRETE EXPANSION ANCHORS SHALL BE WEJ-IT ANKR-TI'IE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT. 9. POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS AND GABLE ENDS. 10. SLAB FOUNDATION SU13GRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FLORIDA BUILDING CODE FIFTH EDITION (2014) (FBC FE 2014) - RESIDENTIAL, AND SECTION 1816.1 OF THE FBC FE 2014 - BUILDING. CONCEALED FASTENERS OR ATTACHMENTS ARE THE pRESPO"BMYOF THE wn� 1111Y I OR OF 'I'HESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAYBE NECESSARY:IN.ORDER TO COMPLY WITH ALL APPLICABLE CODES. LApu t- n3j CT ST. LT rOUNTY RIT11 T`rNG nIVISION REVIEWED FOR CO LLL.CE REVIEWED RY DATE 7 PLANS AND PERINUT MUST BE KEPT ON JOB OR NO ENSPECT10N WILL BE BLADE. THIS IS TO CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 1609 OF THE FLORIDA BUILDING CODE, FIFTH EDITION (2014). THE PLANS ARE VALID UNTIL THE NEXT REVISION OF THE FLORIDA BUILDING CODE. BECHTOL 605 WEST NE' DELAND, FLO \\\\a 1W I1% nOF . z iii:` •'•., FLOR\0?:• �C9\� CAROLINA CARPORTS, INC. 11/30/16 BECHTOL ENGINEERING RR EX NTs AND TESTING inc. rn ucrzc»xr y m wx„ww ,wo wmws msnxo moxme ­• TB ° G16001 TB SHEET1OF4 —WELD ALL WES LEAN-TO RAFTER SET LEA CONNECTIONS, \-B- BELOW TOP OF LEO OVERALL LENGTW :SEI WELD ALL SIDES 3 MONOLITHIC SLAB FOUNDATION 6 OVERALL LENGTH VARIES BOTH SIDES DEPENDS ON NUMBERA - - AI 26 GGALVANIZED METAL ROOF PAN, A —� DEPENDS ON NUMBER AND SPACING OF BOWS 30'-0" FASTENED TO RAFTER WITH #13.14 x SO' SOPS R SI RAFTER SI ANLHORS NOT REQUIRED WITH 6 SIDE EXTENSION WISH GRADE MONOLITHIC SLAS FOUNDATON OR TOP OF CONCRETE CONTINUOUS CONCRETE SLAB WITH CONTROL SEAL WASHER. (OPEN CARPORTS ONLY) --40'-0" MAX. RAFTER SPA TRUSSED BOW SECTION (SEE TAKE 1 FOR FASTENER SPACING) 12 (SEE DETAIL I OR 2 SHEET OF 4) Q3 4 8 BO%EAVE OPTION S 3 6"TYP. GA.RPAI- TIE REND 26GA. ROOFING -J—D $IpEEMENSION 24.18 GA BM SIDE ENOSFASTENED H TORAFTERWITH TO RAF E Z LS PANELSSCBE x FATBLLING(4PEWSAEACH SA14 EACH END(4PERBMCE 21 O� SEE TABLE 1 SEE TABLE 1 SEE TABLE 1 SEE TABLE 1 NUMCUDRSPAN"12L'T 1 OF 4 SHEET 1 OF 4 SHEET 1 OF 4 SHEET t OF 4 WISH GRADE 0 S• 8" MONOLITHIC SUBFOUNDATION CONCRETE 2 E DOWN ENGINEERING, 30" LONG WITH 3 CONTINUOUSCONCRETESIAB (OPEN CARPORTS ONLV) 5/6" R00 AND DBL 4" HELIX EYE ANCHOR (SEE DETNL 3, SHEET 3 OF 4) 30'-0" MAX. RAFTER SPAN 3 ANCHORS HOT MOORED WITH GROUND ANCHORS @ EACH END TYPICAL BOW RAFTER SECTION CONCRETE EEM A IOR2 SSHEET30F4j SIDE ELEVATION RAFTER TERIORPOST AND EVERY OTHER ATIO INTERIOR MFT LOCATION SIDE OPENINGS ANCHORS SILASCREQUIRED NSTRUITN Not To Soak SILAS CONSEST Not TO Scale 2` SHIEST , L-0^1 0( 9, SHEET30F 4) (j7\ Not TO Emla 3 OF 4) (SEE OETAILI DR 3.BXEET90F4) SEE DETAIL l. -Q! 26 GA GALVANIZED METAL ROOF PANELS FASTENED TO METER WRH 2-14x 34° SDFS WITH CONTROL SEAL WASHER 12 (SEE TABLE I FOR FASTENER SPACING) 3 Inc•.n+ictn^.�I�S•-n^,�F'll'�I�.'-TI'++"E'.fl•�-1'-0 6EETABLEI.SHEET101`4 :..v Ma Ms MAX MAX MAX MA —WELD ALL WES LEAN-TO RAFTER SET LEA CONNECTIONS, \-B- BELOW TOP OF LEO WELD ALL SIDES 3 MONOLITHIC SLAB FOUNDATION 6 3 BOTH SIDES Z4 CONTINUOUS CONCRETE SLAB 6 BOX EAVE OPTION 30'-0" 3 R SI RAFTER SI ANLHORS NOT REQUIRED WITH 6 SIDE EXTENSION WISH GRADE MONOLITHIC SLAS FOUNDATON OR TOP OF CONCRETE CONTINUOUS CONCRETE SLAB (SEE DETAIL 1 OR2, SHGT30F4j (OPEN CARPORTS ONLY) --40'-0" MAX. RAFTER SPA TRUSSED BOW SECTION Not To Stele ANCHORS NOT REQUIRED WITH CONCRETE SVB LONSTRRCOQN. (SEE DETAIL I OR 2 SHEET OF 4) #12-14 x 314" SDFS WITH Cot (SEE TABLE 1 FOR BOX EAVE OPTION 3 LEAN-TO RAFTER SET LEA 3 BELOW TOP OF LEO (BOW FRAME OR BD%EAVE) 3 MONOLITHIC SLAB FOUNDATION 6 3 Z4 CONTINUOUS CONCRETE SLAB 3 (OPEN CARPORTS ONLY) 30'-0" 14'-W MAX. SP R SI RAFTER SI ANLHORS NOT REQUIRED WITH CONCRETE STAB CONSTRUCTION (SEE DETAIL 1 OR2, SHGT30F4j TYPICAL SIDE/LEAN-TO EXTENTION SECTION Not To Scale (BOW FRAME LEAN-TO TO BOXE EAVE RAFTER) 26 GA GALVANIZED METAL SIDE PANELS. SECURE WALL PANELS TO RAFTER POSTS AND END POSTS WITH #12-14 x W4' SELF -DRILLING SCREWS W/ CONTROL SEAL WASHER (SEE TABLE 1 FOR FASTENER SPACING) ENDWALL TS POST ANCXORa IM? REQUIRED WITH END WALL OPENING CONCRETE SLAB CnNSTMNcraN (SEE DETAIL t OR 2. SHEET 3 OF 4) Not To Scab GABLED OPEN END WALL SECTION Not To Scale 6 4 4 4 ANCHORS NOT REQUIRED WITH CONCRETE SIAB CON3TRUCMN. (SEE DETAIL T OR 2' SHEET S OF d) END WALL SECTION Not To Smla 26 GA GALVANIZED METAL ROOF PANELS FASTENED TO AFTER WITH #12-14 x XV SOPS WITH CONTROL SEAL WASHER (SEE TABLE 1 FOR FASTENER SPACING) TABLE 1, SHEET 1 OF 4 iA. GALVANIZED fAL ROOF PANELS BOX EAVE OPTION T I MONOUTHIC SLAB FOUNDATION 3 S 4 3 CONTINUOUS CONCRETE SLAB (OPEN CARPORTS ONLY) 14'-0" MAX. SPA ANCHORS NOT REOU IREO WTN CONCRETE BLAB CONSTWCTON. (SEE DETAIL 1 OR 2, SHEET 3 OF 4) I6' x 3D' WITH DBL 4- HELIX WITHIN V OF EACH RAFTER WITH EXTENSIONS (SEE DETAIL 3, SHEET 3 OF 4) TYPICAL FREESTANDING LEAN-TO Not To Scale ANCHORS NOT REWIRED WITH CONCRETE SLAS CONSTRUCTIWI. (SEE DETAIL I OR Z SHEET 3 O 4) TABLE I. SHEET I OF 26 GA. GALVANIZED METAL ROOF PANELS ENDWALL POST METAL SIDE PANELS ROUND ANCHORS @ EACH END RAFTER POST AND EVERY OTHER END POST LOCATION (SEE DETAIL 3 ON SHEET 3 OF 4) NOTE: 14 GA FRAMING IS 2-1/2" X 2-1/2" TUBE STEEL (TEL 12 GA FRAMING IS 2-1/4' x 24/4" TS. NIPPLES ARE 2-1/4" x 2-1/4" 14 GA TS FOR 14 GA FRAMING NIPPLES ARE T x 2" 12 GA TS FOR 12 GA FRAMING. BECHTOL ENGINEERINJ R#W irt$" IF, INC. 605 WEST NEW VORKAVE �y�ryj • I CerBBceteof AUIDA QQ NoN2atict '� Fbrida LfmnsalaOYE � I r F F P F FIIEI,IT )TAT®®OP T�L,�tf�: 10 CAROLINA CARPOIRLITT 'JNC. 1212116 BECHTOL ENGINEERING = "^L' RR 4wT: NTS AND TESTING, Inc 4MaW�42Dnc MV . oNwaMmma, Mo NNonNs TRoNRSN. `°"` TS "°' G16001 ""E°'TB SHEET 2 OF 45TALL 1/2' x MINIMUM 5- EXPANSION ANCHOR THROUCHBASE RAIL WITHIN 6" OF EACH RAFTER/BOW POSTS ALONG SIDES OR INSIDE EVERY OTHER END WALL POST ALONG END WALL SECTIONS MINIMUM Y MINIMUM - MINIMUM 2-112' EMBEDMENT MONOLITHIC CONIC. FOOTING (2500 PSI MIN.) REINFORCED WITH 2 MS'S CONTINUOUS CONCRETE BASE RAIL ANCHORAGE Na To Scale (OPTIONAL) DRILL 5/e' HOLE THROUGH THE r2' WASHERS BASE RAIL AND SECURE TO /I ANCHOR EYE WITH 1/2" DIAMETER TS CONTINUOUS /-SASE BASE RAIL CONTINUOUS 4' CONCRETE PAVEMEWT EYE ANCHOR 5/8" ROD 30" LONG HELIXWITH DBL 4* ALTERNATE CONCRETE BASE RAIL ANCHORAGE Not To Scale (WHERE SLAB IS TOO NARROW TO USE CONCRETE EXPANSION ANCHOR BOLTS) TS RAFTER POST 2'X4' 16 GA PLATE (ONE REQUIRED) SECURE TO EITHER SIDE OF POST/RAFTER CONNECTION WITH (4) 114'. 1"SDPs, 2 ON POST, 2 ON RAFTER TS INSTALL 1YC x MINIMUM 5" EXPANSION ANCHOR THROUGH BASE RAIL WITHIN W OF EACH RAFTER POST ALONG SIDES AND INSIDE EVERY OTHER END WALL POST ALONG END WALL SECTIONS NO SCREWS REQUIRED F�-1-MIN. 6- IN BOW BEND 2-1/2" EMBEDMENT CONTINUOUS 4" CONCRETE PAVEMENT r„�CONCRETE BASE RAIL ANCHORAGE � Na To 6cale (OPTIONAL -OPEN CARPORTS ONLY) DRILL S/8' HOLE THROUGH THE BASE RAIL AND SECURE TO ANCHOR EYE WITH 112" DIAMETER THROUGH -BOLT TOP OF ASPHALT PAVEMENT OR STABLE GROUND SURFACE, EYEANCHOR u 5/8' ROD 30'LONG WITH DBL4'HELM TS CONTINUOUS BASE RAIL s BASE RAIL ANCHORAGE Na ro s6.r RAFTER 24' 16 GA U -CHANNEL BRAC -E0 7' POST)1 1 48" 16 GA U -CHANNEL BRACE (S O 14' POST) E BRACE ANGLE SHALL: BE MIN. 45' a� N� TO MAX. 60' FROM HORIZONTAL 1 � W 24.16 GA U -CHANNEL BRACE (5' TO 7' POST) 48' 16 GA U -CHANNEL BRACE (8' TO 1W POST) BRACE ANGLE SHALL BE MIN. 45' TO MAX. 60' FROM HORIZONTAL SECURE RAFTER AND POST TO NIPPLE WITH (4) 114"x 1" POST SELF -DRILLING FASTENERS BOW RAFTER/POST DETAIL 2 NM To Scale RAFTER 6" LONG TS NIPPLE SECURE POST TO NIPPLE WITH (4)1/4"x 1• SDPs POST %1 BOX EAVE RAFTER/POST DETAIL � Na To Scale NIPPLE TO 3/18' 6" LONG TS NIPPLE RAFTER SECURE WITH (4) 1/4-x1• SDF's 12" LONG TS NIPPLE. SECURE POST TO NIPPLE WITH 14)1/4' x P SDF'S, - 1-1/2"x 1-1/2" x 2" 16 GA CUP ANGLE SECURE TO RAFTER AND GABLE RAIL W/ 41/4"x1" SDPs, 2 ON TOP, 2 ON BOTTOM o 1-1/2' x 1-1/2' x Z'16 GA 6" CLIP ANGLE SECURE TO RAFTER POST AND GABLE RAIL WITH (4)1/4"x1' SOPS 2 ON TOP, 2 ON SIDE TS GABLE RAIL 24.16 GA U -CHANNEL BRACE (5' TO T POST) 48' 16 GA U -CHANNEL BRACE (8' TO 14' POST) TS RAFTER POST BRACE ANGLE SHALL BE MIN. 45' TO MAX. 60' FROM HORIZONTAL TS RAFTER POST SIDE EXTENSION sRAFTER/POST DETAIL Na To 8,816 1-1/T 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) 3/18" x 1" SELF -DRILLING FASTENER SPACED NOT MORE THAN 48" O.C. METAL ROOF PANEL GABLE RAIL TO RAFTER POST CONNECTION DETAIL / Not TO Scale NOTE: 14 GA FRAMING IS 2-1/2' x 2 -IW TUBE STEEL (TSJ 12 GA FRAMING IS 2-1/4"x 24/4" TS. NIPPLES ARE 2-1/4" x 2.1/4.14 GA TS FOR 14 CA FRAMING. NIPPLES ARE 2" x 2" 12 GA TS FOR 12 GA FRAMING. / GAF FOR 14 GA FRAMING 18 STNGAUGE U -CHANNEL BRACE O ••, .�j$ QR �' \ 2A FRA I FASTENED TO THE POST AND ��'•, ••p�OR)aP•°••• �� 2'x2'x2" 16 GA ANGLE CUP 12 GA FRAMING RAFTER WITH (2)114"x T' CE) TS RAFTER / \` RAFTER WITH (4SECURE TO �4- x D Al EACH END (4 PER BRACE) //S'ONA1. O' \\�`\\ SDF's, 2 ON RAFTER, 1,4 2 O POST ROOF PANEL ATTACHMENT (ALTERNATE FOR VERTICAL ROOF PANELS) CAROLINA CARPORTS INC. OST / LEAN-TO RAFTER CONN. DETAIL/ LEAN-TO RAFTER CONN. DETAIL Not To Scale S g Na T. scale BRACE SECTION 11/30)16 Nal To Sa I6 ANE58ECHTOL ENGINEERING e.....ce..w_ .ti RR NTS NIPPLE TC DBL. HDR. 2 6' LONG TS NIPPLE SECURE EACH WITH (4)1/4'x1" SELF -DRILLING FASTENERS RAFTER POST/DBL. HEADER DETAIL Not To Scale 2"x2'x2" 16 CA ANGLE CLIP SECURE TO POST AND RAFTER WITH (4) 1/4" x 1" SDP's, (2) ON BOTTOM, (2) ON SIDE END POST END POST/RAFTER CONN. DETAIL ' Not To Scale 1/4"x 1" SDF a 12" O.C. 3A. ROLL -UP DOOR GUIDE TO POST CONNECTION DETAIL Not To Scale CURTAIN: 26 GA, galvanlzed steel with baked on epoxy primer & polyester top coat. RAFTER POST 6' LONG TS NIPPLE SECURE WITH (4) 1/4"x 1" SELF -DRILLING FASTENERS TS HEADER NIPPLE TO DBL. HDR. RAFTER POST/HEADER DETAIL Not To Scale TS RAFTER POST 1-12" x 1.112"x 2"16 GA CLIP ANGLE SECURE TO POST AND BASE RAIL WITH (4) 1/4'x1" SDF's, (2) ON TOP, (2) ON SIDE "—TS CONTINUOUS BASE RAIL END POST/BASE RAIL CONN. �,Not To Scale TS NONSTRUCTURAL HEADER SWINGING DOOR (Size vanes, see plan) TS POST on 6" LONG TS NIPPLE SECURE EACH WITH (4)1/4'x 1" SELF -DRILLING FASTENERS - QTS POST CONTINUOUS BASE RAIL TO RAFTER POST/BASE BASE RAIL CONNECTION DETAIL Not To Scats POST 2"x 2"x 2' 16 GA ANGLE CLIP SECURE TO POST AND TOP OF HEADER, OR BOTTOM OF WINDOW RAIL/GIRT WITH (4) 1/4'x 1"SDP's (2) ON TOP OR BOTTOM, (2) ON SIDE TS NON-STRUCTURAL HEADER TS WINDOW RAIL (OR GIRT FOR VERTICAL SIDING OPTION) NON-STRUCTURAL HEADER, WINDOW RAIL, OR GIRT TO POST CONN. DETAIL �� Not To Scale A SECTION Not To Scale 114'x 1' SDF 12" O.C. �1= TS TRUSSED RAFTER CHORD, OR NON-STRUCTURAL HEADER TS END POST OR DOOR/ WINDOW FRAME POST TS BASEANINDOW RAIL OR NON-STRUCTURAL HEADER 2'x2'x2' 16 GA ANGLE CLIP SECURE TO POST (EACH SIDE) AND RAFTER CHORDIRAIL WITH (4) 1/4'x1" SDF's, (2) ON TOP OR BOTTOM, (2) ON SIDE NOTE: AT ROLL -UP DOOR OPENINGS, POST SHOULD BE FLUSH WITH RAIL END. CLIP POST TO RAIL ONLY ON SIDE OPPOSITE THE OPENING. POST TO RAIL, TRUSS CHORD, OR NON-STRUCTURAL HEADER CONN. DETAIL Y Not To Scale 6" LONG TSNIPPLE SECURE POST TO NIPPLE WITH (4)1/4'x 1' SDF's NIPPLE TO 3/16" BASE RAIL TS CONTINUOUS BASE RAIL Is POST/BASE RAIL CONN. DETAIL � Not Ta Scale NOTE: 14 GA FRAMING IS 2-1/2" x 2-1a' TUBE STEEL ITS). 12 GA FRAMING IS 2-1/4" x 2-1/4" TS. NIPPLES ARE 2.1/4' x 2.1/4" 14 GA TS FOR 14 GA FRAMING. NIPPLES ARE 2' x 2' 12 GA IS O 1 (If ft FRAMING. "\``e� R 11u11 BECHTOL ENO 1N"* tr 665 WEST NEW y'B 1 NUE d r DELAND, FLORIq)l O ••, 0� ' Cer66cateot Au6lpn r N7, 8 Thomas Be tol;7.F Florida Licei ee.NQ,3 STATE OF FG0Rk O, c /ONA%,