SCOPE OF WORK:
ESIGNED PER:
INSTALLATION OF A90LM WATER HEATNO
AGI
SYSTEM WITH AZO TOP COLLECTOR
lv
I
7 6
WIND LOA. WIND: RISK CATEGORYII
DESIGNED FuR 200 MPH. EXPOSURE CATEGORY D
il
SDHW (SOLAR DOMESTIC HOT WATER) PLAN
INSTALLATIONS MADE IAW (IN ACCORDANCE WITH) THIS PLAN WILL NOT ADVERSELY
IMPACT THE ABILITY OF THE HOST STRUCTURE TO HANDLE WIND FORCES PREDICTABLE
IAW ASCE 7. IT 15 RECOMMENDED THAT DOMESTIC HOT WATER SOLAR COLLECTORS
BE INSTALLED AT A TILT ANGLE FROM THE HORIZONTAL OF FROM 10 -TO -40 -DEGREES
& FACING WITHIN 45 -DEGREES OF TRUE SOUTH. THIS PLAN SHALL BE ACCOMPANIED
BY AN ALTERNATE PLUMBING DETAIL WHEN CONTRACTOR USES PLUMBING
ARRANGEMENTS SUCH AS DRAIN -BACK, CLOSED-LOOP, ETC, COLLECTOR HEREIN
SPECIFIED HAS A WIND PRESSURE RATING OF -102 PSF. THIS GENERIC PLAN APPLIES
ONLY TO INSTALLATIONS IN ROOF PRESSURE ZONE 1 (PZ1) OR ROOF PRESSURE ZONE 2
(PZ2) - SEE DRAWINGS & WIND CALCULATIONS. INSTALLATIONS IN PZ3 REQUIRE
SITE-SPECIFIC PLANS.THE DETAILS SPECIFIED ON THIS "PAPER" PLAN ARE INTENDED TO
PROVIDE ESSENTIAL INFORMATION NEEDED BY AHJ (AUTHORITY HAVING
JURISDICTION AKA BUILDING DEPARTMENT) & INSTALLERS. USERS ARE ENCOURAGED
TO ACCESS EV (ELECTRONIC VERSION) OF THIS PLAN ON EOR (ENGINEER OF RECORD)
WEEPAGE -LINK/ASSISTANCE WILL BE PROVIDED UPON REQUEST. ACTIVE HYPERLINKS
ON EV PROVIDE EASY ACCESS TO SUPPLEMENTAL INFORMATION. EV ALSO ALLOWS
VIEWER TO STUDY THE PLAN AND OEM (ORIGINAL EQUIPMENT MANUFACTURER)
DETAILS AT MAGNIFICATIONS OF VIEWER CHOICE UP TO 6400%. IF A CONFLICT
SHOULD OCCUR BETWEEN A DRAWING AND/OR SPECIFICATION HEREON AND AN OEM
DETAIL, OEM SHALL PREVAIL, USERS ARE ENCOURAGED TO ACCESS OEM INSTALLATION
MANUAL WHICH SHALL BE PROVIDED BY CONTRACTOR UPON AHJ REQUEST OR CAN BE
VIEWED ONLINE USING ELECTRONIC PLAN VERSION HYPERLINKS. HOLD DOWN
ANCHORS SHALL BE (MINIMUM) 5/16TH INCH DIAMETER CRS (CORROSION RESISTANT
STEEL- VULT 160_ MPH AND UNDER) - LAG MINIMUM DIAMETER INCREASED TO 3/8 -
INCH IN WIND ZONES ABOVE VULT 160 MPH. TILT UP 15 -DEGREES OR GREATER
ABOVE ROOF PLANE AT WIND SPEEDS 160 -MPH OR GREATER REQUIRES SITE-SPECIFIC
ENGINEERING. STANDARD ROOF ATTACHMENT SPECIFICATION: THERE SHALL BE
MINIMUM FOUR ROOF ATTACHMENTS PER COLLECTOR (HVHZ REQUIRES 6). THESE
MAY BE ON SHORT OR LONG SIDE OR BOTH. MINIMUM ATTACHMENT SEPARATION
SHALL BE SIDE/3. ROOF ATTACHMENTS MAY BE LAGS ACHIEVING 3- INCH SOLID
THREAD EMBEDMENT IN ROOF FRAMING OR BLOCKING, OR APPROVED ALTERNATE
ANCHOR. APPROVED ALTERNATIVE ANCHORS INCLUDE: LAGS INTO ROOF FRAMING OR
BLOCKING (MIN 4"X4"X9"), 3/8" DIAMETER J -BOLTS HOOKING FRAMING OR BLOCKING,
OR MIN 3/8" DIAMETER ALL -THREAD ROD THRU SPANNER OR BLOCKING.
CONTRACTOR SHALL USE INSTALLATION HARDWARE & FLASHINGS CONTAINED IN OEM
INSTALLATION KITS. ALTERNATE MEANS & METHODS ACCEPTABLE TO AHJ MAY BE
USED AT CONTRACTOR'S SOLE RISK. EOR PREFERS EMAIL alien@gezelmanpe.es:
LEDCTEND
_Isou I r VALVE ITibT18N4L).
TANK SUPPLY SHUT OW
SOLAR L P-0MIN 10 I NAL)
E PROTECTION.VgLVE (OPTIONAL,)
MPERATURENRE39URE RELIEF VALVE
PRESSNRE RELIEF VALVE
AIR VENT(O TIONAL
MOTORIZED BALL VALVE
ELECTRIC PUMP ACLOC
EXPANSION TANK (OPTIO L
5 I 4 I
SOLAR SYSTEM COLLECTOR: APPLICABLE CODE'
MODEL. AE - N IAER6I AE-26
9 1 8 1 7
ROOF ATTACHMENTS USING OEM
MANUFACTURER) MOUNTING HARDWARE SHOWN IN �(
FIGUREBMAY BEATTACHED TO EITHER THE SIDES OR
ENDS OF THE SOLAR COLLECTOR(S)UR 80TH.
Dx TYPICPL ROOF INSTALLATION.
ALL
THREAD ROD,
J BOLTOR LAG
MaurvnNa
eRACKrr
ALUM. TUBE
PITCH PAN L I
/AE.18/AE$I ]019 (SM EGITION)FLONDA BUI4 NG
Acro rust-z1/Msc-TB/M309z/Macao
ALUM, TUBE
PH.613 9091956
Allen@tiezellnaAPE:com
wWW.GezelmanPE tom
HE
ROD, —
JBOLT OR LAO
TILE ROOF: CUT OUT RECTANGLE FOR PITCH PAN,
INSTALL AND FILL Wl1-PART POURABLE WATER PROOF
CONSTRUCTION SEALANT
ALTERNATE TILE ROOF MOUNTING DETAIL.
=3.
..VV
OS
GIE:3".yp
,,,,, `FRONT ELEVATION.
TWE: F+1'p'
05 FGRAMI�G ATTACHMENT.
'.*4 t'/-20Xj'HEXCAPSCREW
1'x1-xj"ALUMINUM\`—�.i8x6'HEX LPP BCREW
6pWRETUBE ® �O
TRIANGULAR.
MOUNTINGBRACKET\ 16x1-QHEXCAPBOREW
08 TICAL MOUNTING DETAIL &TILT KIT -DECK ANCHOR.
SGLE HR
I F
DECKING
PZ: PRESSURE ZONE
e 6 k
3 I 2 I
VOID WITHOUT RAISED OR ELECTRONIC SEAL, MAY NOT PF USED FOR PLANS ON
FILE, EVERY PERMIT PULLED REQUIRES
COOLIE' CAP
aum RUBBER
SEALED ELECrr PIAN OR SEALED
ORIGINAL PAPER COPY OF THE PLAN.
SDHW COLLECTOR
04 LEE'
LE: L•=po10
PZ 1
FOOT
FILL WN -PART —�
POURABLE
WATERPROOF
CONSTRUCnON
SEALANT
ALUM. TUBE
PITCH PAN J
ALL THREAD
/ \—�RUSSx4
sT. LurIE co(wrY
BUILDING DIVISION
REVIEWED BY
DATE _ /
RACK MOUNT SYSTEM (RMURUUSH MOUNT SYSTEM (FM) STANDARDMOUNTSYSIFEM(RM)
CO
FLASPI
MUST BE KEPT ON JOB OR
NO INliPECTION WILL BE MADE
1
ENGINEER
ALLEN GE2ELMAN
16502 HANNA R0.
LUTZ. FLORIDA 33509 Q
Lm
59180
Io 1§114�
DRAFTSMAN:
ALPER ICELI
alpericeli(OJmaiLusY.etluLL LIJ
Of
wrrv.N"lev"re00e.wm
---RAFTER RgFTER—
APPLY Ill..•'ll —'.QED/RETURN _ ALL ROOFING
SEALANT PLUMBING� TYPES
ALL ROOFIN e
TYPES
1-100 NAIL ORSCREJJ+ `9"x4"SPANNER (IT OC RAFTERS)
ROOF FLASHING DETAIL AT E4Ln RAFTER 7x6'sPANNER (2a^OC R4TER3)
STNNLE589TEEL Tx]"x,,}"STEEL ANGLE SPANNER
APPLY ROOFING SEALANT TO THE UNDERSIDE OF PUT-wgsnER, -e0 rvga oR SCRERv
THE FLASHING BASE PRIOR TO THE INSTALLATION. LOCK WAGNER AND rvuT AT EACH SPACER SLOCrc
AE -P, SPANNER. USE WIN ANV ROOF TYPE.
� .UE
C;
SYSTEM SCHEMATIC
THIS DRAWING SHOWS DIRECT SYSTEM PLUMBING WITH 310 VOLT A/C CONTROL & PUMP.
THERE ARE OTHER VERSIONS
(CLOSED-LOOP GLYCOL, DRAIN -BACK, PV PUMP) WHICH ARE
ALSO COVERED BY THIS SEALED PLAN, BECAUSE THE CRITICAL ELEMENTS, COLLECTOR ROOF
MOUNTING DETAILS, REMAIN THE SAME.
lv
I
COLLECTOR SENSOR
I
I
I
I
- --- --
SOLAR LOOP DRAIN
SOLAR LOOP
DRAIN
ISOLATION VALVE
MOTORIZED
EXPANSION TANK
BALL VALVE
ET DIFFERENTIAL CONTROL
HOT WATER
OUTLET
COLD WATER INLET
BACKUP ELECTRIC
it II 41 : SHUT OFF VALVE
ELEMENT
DIP TUBE
-:
11
STORAGE TANK
JF
1 R U�`
TANKSENSOR
II II,'.
D,
)j
TANK DRAIN
�
3^PWMSwG.
sum:xTs
LEDCTEND
_Isou I r VALVE ITibT18N4L).
TANK SUPPLY SHUT OW
SOLAR L P-0MIN 10 I NAL)
E PROTECTION.VgLVE (OPTIONAL,)
MPERATURENRE39URE RELIEF VALVE
PRESSNRE RELIEF VALVE
AIR VENT(O TIONAL
MOTORIZED BALL VALVE
ELECTRIC PUMP ACLOC
EXPANSION TANK (OPTIO L
5 I 4 I
SOLAR SYSTEM COLLECTOR: APPLICABLE CODE'
MODEL. AE - N IAER6I AE-26
9 1 8 1 7
ROOF ATTACHMENTS USING OEM
MANUFACTURER) MOUNTING HARDWARE SHOWN IN �(
FIGUREBMAY BEATTACHED TO EITHER THE SIDES OR
ENDS OF THE SOLAR COLLECTOR(S)UR 80TH.
Dx TYPICPL ROOF INSTALLATION.
ALL
THREAD ROD,
J BOLTOR LAG
MaurvnNa
eRACKrr
ALUM. TUBE
PITCH PAN L I
/AE.18/AE$I ]019 (SM EGITION)FLONDA BUI4 NG
Acro rust-z1/Msc-TB/M309z/Macao
ALUM, TUBE
PH.613 9091956
Allen@tiezellnaAPE:com
wWW.GezelmanPE tom
HE
ROD, —
JBOLT OR LAO
TILE ROOF: CUT OUT RECTANGLE FOR PITCH PAN,
INSTALL AND FILL Wl1-PART POURABLE WATER PROOF
CONSTRUCTION SEALANT
ALTERNATE TILE ROOF MOUNTING DETAIL.
=3.
..VV
OS
GIE:3".yp
,,,,, `FRONT ELEVATION.
TWE: F+1'p'
05 FGRAMI�G ATTACHMENT.
'.*4 t'/-20Xj'HEXCAPSCREW
1'x1-xj"ALUMINUM\`—�.i8x6'HEX LPP BCREW
6pWRETUBE ® �O
TRIANGULAR.
MOUNTINGBRACKET\ 16x1-QHEXCAPBOREW
08 TICAL MOUNTING DETAIL &TILT KIT -DECK ANCHOR.
SGLE HR
I F
DECKING
PZ: PRESSURE ZONE
e 6 k
3 I 2 I
VOID WITHOUT RAISED OR ELECTRONIC SEAL, MAY NOT PF USED FOR PLANS ON
FILE, EVERY PERMIT PULLED REQUIRES
COOLIE' CAP
aum RUBBER
SEALED ELECrr PIAN OR SEALED
ORIGINAL PAPER COPY OF THE PLAN.
SDHW COLLECTOR
04 LEE'
LE: L•=po10
PZ 1
FOOT
FILL WN -PART —�
POURABLE
WATERPROOF
CONSTRUCnON
SEALANT
ALUM. TUBE
PITCH PAN J
ALL THREAD
/ \—�RUSSx4
sT. LurIE co(wrY
BUILDING DIVISION
REVIEWED BY
DATE _ /
RACK MOUNT SYSTEM (RMURUUSH MOUNT SYSTEM (FM) STANDARDMOUNTSYSIFEM(RM)
CO
FLASPI
MUST BE KEPT ON JOB OR
NO INliPECTION WILL BE MADE
1
ENGINEER
ALLEN GE2ELMAN
16502 HANNA R0.
LUTZ. FLORIDA 33509 Q
Lm
59180
Io 1§114�
DRAFTSMAN:
ALPER ICELI
alpericeli(OJmaiLusY.etluLL LIJ
Of
wrrv.N"lev"re00e.wm
---RAFTER RgFTER—
APPLY Ill..•'ll —'.QED/RETURN _ ALL ROOFING
SEALANT PLUMBING� TYPES
ALL ROOFIN e
TYPES
1-100 NAIL ORSCREJJ+ `9"x4"SPANNER (IT OC RAFTERS)
ROOF FLASHING DETAIL AT E4Ln RAFTER 7x6'sPANNER (2a^OC R4TER3)
STNNLE589TEEL Tx]"x,,}"STEEL ANGLE SPANNER
APPLY ROOFING SEALANT TO THE UNDERSIDE OF PUT-wgsnER, -e0 rvga oR SCRERv
THE FLASHING BASE PRIOR TO THE INSTALLATION. LOCK WAGNER AND rvuT AT EACH SPACER SLOCrc
AE -P, SPANNER. USE WIN ANV ROOF TYPE.
� .UE
C;
NR
10 5 1E, xn
a
Y.
7
SYSTEM:
L E
_—
i BRACKET W3 GUNN HIGHWAY
OOE554]9558
, FL
81310
358 BP
REQUIRED)
1 LDR-DHW
REV 09.15 I F
A
B
C
D
E
F
9 1 8 1 7 1 6 1 5 1 4 6 3 1 2: I 1
9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1
A
B
C
D
E
F
PERIMETER MIN 3-FT=10% LEAST BLDG L/W OR
PZ2 LEFT -RIGHT & UP -DOWN
- -
KOPMASOIAR\
ENEAGVCENTER
Certification Facility,
FSEC/UCF
1679 Clearlake Road
Cocoa, FL. 32922 USA
www:fsec.ucf.edu
II► �i
Supplier:
The LeverEdge
1423 Gunn Highway
Odessa, FL. 33556 USA
www.theleveredRe.com
THESE CALCULATIONS COVER MOS )NDITIONS-CONTACT ENGINEER
FOR DIFFERING. SEE PARAGRAPH`3609 2014 FBC FOR DETAILS NOT
CLEAR
PZ3 IS ROOF INTERIOR SURROUNDED BY PZ2 ROOF
40% EAVE HEIGHT-PZ3 ROOF CORNERS=
Risk II, Exposure B, up -lift pressure, psf, 15 -ft or
less
Exposure C, uplift pressure, psf, 15 -ft or less
Exposure D, uplift pressure, psf, 15 -ft or less
DEGREES
roof slope <7 7< roof slope <27
roof slope<7 7< roof slope <27
roof slope<7
7< roof slope 4277
Design Wind Speed
pZi I PZ2 PZ3 PZ1 PZ2 PZ3
PZ1 PZ2
PZ3 PZ1
PZ2 PZ3
PZ1 PZ2 PZ3
PZ1 PZ2 PZ3
Vult-mph Vasd-mph
psf psf psf psf psf psf
psf psf
psf psf
psf psf
psf psf psf
psf psf psf
110 85.2
11.1 19.9 31.0 10.0 17.7 25.9
13.4 24.1
37.5 12.0
21.4 31.3
16.3 29.3 45.5
14.6 26.0 38.0
115 89.1
12.1 21.8 33.8 10.9 19.3 28.3
14.6 26.3
40.9 13.2
23.4 34.2
17.8 32.0 49.7
16.0 28.4 41.6
120 93.0
13.2 23.7 36.8 11.8 21.1 30.8
15.9 28.7
44.6 14.3
25.5 37.3
19.3 34.8 54.2
17.4 31.0 45.3
125 96.8
14.3 25.7 40.0 12.9 22.8 33.4
17.3 31.1
48.4 15.6
27.6 40.4
21.0 37.8 58.8
18.9 33.6 49.1
130
100.7
15.4 27.8 43.2
13.9
24.7
36.1
18.7
33.6
52.3
16.8
29.9
43.7
22.7 40.9
63.6
20.4
36.3
53.1
Certified
Solar Thermal
Systems
135 104.6
16.7 30.0 46.6 15.0 26.6 39.0
20.2 36.3
56.4 18.1
32.2 47.2
24.5 44.1 68.6
22.0 39.2 57.3
140 108.4
17.9 32.2 50.2 16.1 28.7 41.9
21.7 39.0
60.7 19.5
34.7 50.7
26.3 47.4 73.7
23.7 42.1 61.6
145 112.3
19.2 34.6 53.8 17.3 30.7 45.0
23.3 41.9
65.1 20.9
37.2 54.4
28.2 50.8 79.1
25.4 45.2 66.1
Model
Thermal System
Type
Certification #Expiration
Date
FEF
North
FEF
Central
FEF
South
150 116.2
20.6 37.0 57.6 18.5 32.9 48.1
24.9 44.8
69.7 22.4
39.8 58.2
30.2 54.4 84.6
27.2 48.4 70.7
155 120.1
22.0 39.5 61.5 19.8 35.1 51.4
26.6 47.8
74.4 23.9
42.5 62.2
32.3 58.1 90.4
29.0 51.6 75.5
160 123.9
23.4 42.1 65.5 21.1 37.4 54.7
28.3 51.0
79.3 25.5
45.3 66.2
34.4 61.9 96.3
31.0 55.0 80.5
0-50-21
Pumped, Direct
300511
9/22/2034
1.70
1.70
1.70
165 127.8
24.9 44.8 69.7 22.4 39.8 58.2
30.1 54.2
84.3 27.1
48.2 70.4
36.6 65.8 102.4
32.9 58.5 85.6
170 131.7
26.4 47.5 74.0 23.8 42.3 61.8
32.0 57.5
89.5 28.8
51.1 74.8
38.8 69.9 108.7
34.9 62.1 90.9
175 135.6
28.0 50.4 78.4 25.2 44.8 65.5
33.9 61.0
94;8 30.5 -
54.2 79.2
41.1 74.1 115.2
37.0 65.8 96.3
0-66-32
Pumped, Direct
300512
9/22/2034
1.70
1.80
1.80
180 139.4
29.6 53.3 82.9 26.6 47.4 69.3
35.8 64.5
100.3 32.2
57.3 83.8
43.5 78.4 121.9
39.2 1 69.6 101.9
185 143.3
31.3 56.3 87.6 28.2 50.0 73.2
37.8 68.1
106.0 34.1
60.6 88.6
46.0 82.8 128.7
41.4 73.6 107.6
190 147.2
33.0 59.4 92.4 29.7 52.8 77.2
39.9 71.9
111.8 35.9
63.9 93.4
48.5 87.3 135.8
43.6 77.6 113.5
0-80-40
Pumped, Direct
300510
9/22/2034
2.10
2.20
2.20
195 151.0
34.8 62.6 97.3 31.3 55.6 81.3
42.0 75.7
117.7 37.8
67.3 98.4
51.1 92.0 143.0
46.0 81.7 119.5
200 154.9
36.6 65.8 102.4 32.9 58.5 85.5
44.2 79.6
123.9 39.8
70.8 103.5
53.7 96.7 150.5
48.4 86.0 125.7
Risk II, Exposure B, up -lift pressure, psf, 30 -ft or
less
Exposure C, uplift
pressure, psf,
30 -ft or less
Exposure D, uplift pressure,
psf, 30 -ft or less
0-120-64
Pumped, Direct
300504
9/22/2034
4.40
4.40
4.40
DEGREES
roof slope <7 7< roof slope <27
roof slope<7
7< roof
slope <27
roof slope<7
7< roof slope <27
Design Wind Speed
PZ3
PZ2
PZ3
PZ1
PZ2
PZ3
PZ1
PZ2
PZ3
PZ1
PZ2
PZ3
PZ1
PZ2
PZ3
PZ1
PZ2
PZ3
0-120-80
Pumped, Direct
300505
9/22/2034
4.40
4.40
4.40
110 85.2
11.1 19.9 31.0 10.0
17.7 25.9
15.5 27.9 43.3 13.9
24.8 36.2
18.4
33.0
51.4 16.5
29.4
43.0
115 89.1
12.1 21.8 33.8 10.9
19.3 28.3
16.9 30.5 47.4 15.2
27.1 39.6
20.1
36.1
56.2 18.1
32.1
46.9
120 93.0
13.2 23.7 36.8 11.8
21.1 30.8
18.4 33.2 51.6 16.6
29.5 43.1
21.8
39.3
61.2 19.7
35.0
51.1
OPV -66-32
Pumped, Direct
300509
9/22/2034
2.40
2.60
2.60
125 96.8
14.3 25.7 40.0 12.9
22.8 33.4
20.0 36.0 56.0 18.0
32.0 46.8
23.7
42.7
66.4 21.3
37.9
55.5
130 100.7
15.4 27.8 43.2 13.9
24.7 36.1
21.6 38.9 60.5 19.5
34.6 50.6
25.6
46.2
71.8 23.1
41.0
60.0
135
104.6
16.7
30.0
46.6
15.0
26.6
39.0
23.3
42.0
65.3
21.0
37.3
54.6
27.6
1 49.8
77.4
24.9
44.2
64.7
OPV -80-40
Pumped, Direct
300506
9/22/2034
3.20
3.50
3.50
140 108.4
17.9 32.2 50.2 16.1
28.7 41.9
25.1 45.1 70.2 22.6
40.1 58.7
29.7
53.5
83.3 26.8
47.6
69.6
145 112.3
19.2 34.6 53.8 17.3
30.7 45.0
26.9 48.4 75.3 24.2
43.0 62.9
31.9
57.4
89.3 28.7
51.0
74.6
150 116.2
20.6 37.0 57.6 18.5
32.9 48.1
28.8 51.8 80.6 25.9
46.1 67.4
34.1
61.4
95.6 30.7
54.6
79.9
OPV -120-64
Pumped, Direct
300507
9/22/2034
6.30
7.20
7.20
155 120.1
22.0 39.5 61.5 19.8
35.1 51.4
30.7 55.3 86.1 27.7
49.2 71.9
36.4
65.6
102.1 32.8
58.3
85.3
160 123.9
23.4 42.1 65.5 21.1
37.4 54.7
32.8 59.0 91.7 29.5
52.4 76.6
38.8
69.9
108.7 35.0
62.1
90.9
165 127.8
24.9 44.8 69.7 22.4
39.8 58.2
34.8 62.7 97.5 31.4
55.7 81.5
41.3
74.3
115.6 37.2
66.1
96.6
OPV -120-80
Pumped, Direct
300508
9/22/2034
6.30
7.20
7.20
170 131.7
26.4 47.5 74.0 23.8
42.3 61.8
37.0 66.6 103.5 33.3
59.2 86.5
43.8
78.9
122.8 39.5
70.2
102.6
175 135.6
28.0 50.4 78.4 25.2
44.8 65.5
39.2 70.5 109.7 35.3
62.7 91.7
46.5
83.6
130.1 41.8
743
108.7
180 139.4
29.6 1 53.3 82.9 26.6
47.4 69.3
41.5 74.6 116.1 37.3
66.3 97.0
49.2
88.5
137.6 44.2
78.6
115.0
185 143.3
31.3 56.3 87.6 28.2
50.0 73.2
43.8 78.8 122.6 39.4
70.1 102.5
51.9
93.5
145.4 46.7
83.1
121.5
128.2
These systems were evaluated by the Florida Solar Energy Center (FSEC) in accordance with
the Standards Program for Solar Domestic Water and Pool Heating Systems (FSEC Standard
104-10) and were found to meet the minimum standards established by FSEC.
190 147.2
33.0 59.4 92.4 29.7
52.8
46.2 83.1 129.3 41.6
73.9 108.1
54.8 ,
98.6
153.3 49.3
87.6
195 151.0
34.8 62.6 97.3 31.3
55.6
t85.5
48.7 87.6 136.2 43.8
77.8 113.8
57.7
103.8
161.5 51.9
92.3
135.0
200 154.9
36.6 65.8 102.4 32.9
58.5
51.2 92.1 143.3 46.1
81.9 119.8
60.7
109.2
169.9 54.6
97.1
142.0
9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1
A
B
C
D
E
F