Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED Design Pressures
Florida Window & Door Co. 1 125 N.Dixie Hwy Tel.(561)848-4900 LakeWorth, FL 33460 Floridawindowanddoor.com Property Information Building Information Owner: Michael Bonville Wind Zone: 160 MPH. Address: 4102 Sunrise Blvd Exposure Category: C Fort Pierce,FL 34982 Minimum Building Dimension: 30 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 End 111 63 7 30.0 -38.0 2 End 74 63 7 30.9 -39.7 3 End 37 38 7 33.5 -44.8 4 End 37 38 7 33.5 -44.8 5 End 74 38 7 32.0 -41.9 6 End 37 38 7 33.5 -44.8 7 End 74 38 7 32.0 -41.9 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1