Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
wri, Project Summary Job: : Entire House By. QUICK CALLS, INC. For: THE GRAND:CARLTON.IMPACT, . WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer'Design Conditions Outside db 42 OF Outside db 90. OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF . Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh Central: vent (0 cfm) 0 Btuh (none). (none). Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Rate/swin multipplier Equipmen 0.95 24753 Btuh Infiltration sensibleload Method Simplified Latent Cooling Equipment Load Sizing Construction ,quality Average Fireplaces 0 Structure 3203 Btuh Duds 2318 Btuh Central: vent (0 cfm) 0. Btuh Heatingg Coolingg (none): Area (fF) 1446 .1446 Equipment latent load 5521 Btuh Volume (ft3). 12511 12511 Air changes/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 30274 Btuh Equiv AVF (cfm) 94 .48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536XO30 Cond 25HBC5369030 . AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating input Sensible cooling. 24360. Btuh Heating output 34600 Btuh @47°F Latentcooling 10440 Btuh Temperature. rise 27. OF Total cooling . 34800. Btuh. Actual airflow 1160 cfm . Actual airflow 1160. dm Airflow factor 0.049 cim/Btuh Airflow factor 0.045 drnBtuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 32 OF Backup: Input = 7 kW; Output = 23009 Btuh;100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. - } 09/r��%• ® 2020-Jao-081620.47 . ntn wwisawnnsm.row.�.cs m RigitSute® Uriversa1201919.0.07 RSU08101 Rt.i6i1?4 Page 1 iglboftWACMiEGRAND CARLTON-1446-IMPACT.np Cale =MJ8 Frord Door faces: N a= Right-J® Worksheet Job. Entire House Date: QUICK CALCS, INC. By 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6798 Email: QUICKCALCS@/,OL.COM 1 Room name Entire House BEDROOM 2 . Fed wall. 1562 ft 49.0 ft 3 Room height 8.7 It d 8D ft heatf000l 4 5 Room dimensions Room area 1445.5 iF 1.0. x 297D ft 297.0 IF Ty Construction U-value Or HTM Area Area(ft) Load number (Btuh/fF-°F) (BluhfiF) or perimeter (ft) (Btuh) or perimeter (ft) (Bluh) Heat Cool Gross NOS Heat Cool Gross NIPS Heat Cool 6 W. 13AA=S 0.143, n 4.00 2.55 563 465 . 1862 - 72 72 28Q 183. 4A5=2om 0.770 n' 2156 19.31 : .38 0 . 815 .1184 730 . 0 0 :0 : 0 13A-4ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 1Ac1om 1270 a 35.56 8729 24 2 848 2082 0 0 0 0 D 11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W . -13AAocs. ° 0.143 se. 4.00. . ,2.55 - 34 34 136. .86 :. 0 0 0 0 t-G 13AAocs 0.143 s 4.00 2.55 360 353 1414 899 216 216 865 550 1Aclom 1270 a 35.56 34.77 7 7 247 241 0 0 0 0 13A-21[ocs 0143 ` w 4.00 2.55 ' 310 ' 237 . 945 603 104 : 72 288 '183 1Ac1om.. 1270: w 35.56 5591 .. 32 2 1140 1770 32 .2 1140 1770 :4A5-2om . 0.770 w 21.56 19.31 41.. 41 880 -788 0 0 0 . 0 P 12C-0sw 0.091 2.55 128 192 192 489. 246 0 0 0 0 C 16A:30md 0.032 =- 0.96:: 2.32 .1446 1440 1295 - • M54 297 " 297 -266 689 F 22A tpl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c) AED excursion 918 627 Envelope loss(gain 14961 .13349 4204 4003 12 a) Infiltration 2687 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 6 1380 3 690 Appliancedother 2000 1 0 Subtotal (lines 6to13) 17848 17520 5053 4925 Less exsmalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Ductloads 32% 49% 5654 8536 .32% 49°/a 1601 2400 Total room load 23503 26056 66M TV5 Air required (dm) 1160 1160 1 1 328 326 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -� -rid- writg)tirso�rV, 2020-JarF081620:47 A Right-SUtaOUniversal 201919.0.07 RSU08101, Page 1 :.ighlsotWACITHEGRANDCARLTON-1446-1MPACT.nip CaJc=,NU8 Fron<Doorfaces: N ALL 91Fti Right-JO Worksheet Entire House QUICK CALLS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: By. 1 Room name WIC KrrCHEN 2 Exposed wall. O ft O It 3 Room height 8.0 ft heafl000l 8.0 ft heaUcool 4 5 . Room dimensions Room area 6.0 x 9.0 ft 54.0 fF 1.0 x 172.0 ft 172.0 fN Ty Construction U-value Or HTM Area (ft') Load Area (ftF Load number (Bluh/RZ-°F) (BlulUft�) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Coal Gross . N/P/S Heat Cool Gross NIPS Heat Cool 6 �G 'LG13A-4ocs 13A ocs .0&26m:" 0143 0.776 0.143 -n n a 4.00 - 21.`.56 4.00 255. :19.31 2.55 b 0..... 0 0 0 0 0 .0 0 0 .0' 0 0 0 0 0 0 0 0 0'. 0 0. 0 0 11 1A-clom 11D0 1270 0.390 a a 35.56 10.92 8729 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D W:1 WL--G 13AAocs 1A-clom 0.143 0.143 1270 se: s s 4.00 4.00 35.56 2.55 2.55 34.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .0 0 0 13A-4as 0.143:` w 4.06 2.55 0 - 0 0 0 0 0 0 0 IA-clom . 1270 w. 35.56 55.21 0 0 0 0 :0 0 0 0 AA5-26m : 07.0 w- 21.56 1931 0 , 0 - 0 .0 0 0 0 . 0 �C P 12C-Osw 0.091 - 2.55 .128 0 0 0 0 64 64 163 82 C , . 16A30md :0.032 0.90 2..32 54 ' 54 48 125 172 -172 154 399 F 22A ttpl 0.989 - 27.69 " 0.00 54 0 0 0 172 0 0 0 6 c)AEDexcursion -9 -170 Envelope losalgain 48 117 317 311 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 AppliancWother 0 2000 Subtotal (lines 6 to 13) 48 11.7 317 2311 Less external load 0 0 0 0 Lesstransfer 0 0 0, 0 Redistribution 0 0 0 0 14 . Subtotal 48 117 317 2311 15 Dud loads 32% 49% 15 57 32% 49% 100 1126 Total room load 1 64 174 418 3437 Air required (dim) 3 8 21 153 Calculations approved WACCA to meet all requirements of Mantaal 'J 8th Ed. - wrlglp so C^ 2020-Jan-0816:20:47 .9Mk RigttSute®Uriversar2019:19.0.OZ RSU08101 Page 2 ig%oftWAC1THEGRAND CARLTON-1446-1MPACT.np Calc=W8 Front Door faces: N . - wrlotsofr, Right-M WOksheet Entire House QUICK CALLS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946.Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job. Date: BY 1 Room name BATH BEDROOM2 2 E)posed wall 6.0 ft 342 ft 3 Room height 8.0 It heat/cool 8.0 ft heat/000l 4 5 Room dimensions Room area 9.0 x 5.0 ft 45.0 W 1.0 x. 2035 It 203.5 ft Ty Construction U-value Or HTM Area Load number (Btuh/it{°F) (BtuhlR� or perimeter (ft) (Btuh) oorperimeetter (ft) (Btuh) Heat Cool Gross Nips Heat Cool Gross NAS Heat Cool 6 13AAocs .4A52om..... _ 0143 0.7,70 n. ri:. 4.00 21`.56' ` 2.55 `.: 19.31 40 ::. . 0 40 0 160 .. 0. 102 0 128 . A 128 0 M 0 326. ;. 0 .'G 13AAocs 0.143 a 4.00 2.55 0 0 0 0 80 56 225 143 11 1Ao1om 11DO 1270 0.390 a a 35.56 10.92 8729 11.31 0 0 0 0 0 0 0 0 24 0 2 0 848 0 2082 0 D W .. yJ G 13AAocs 13AAocs 0.143' 0.143 se s 4.00. 4.00 -2.55 2.55 - 0 0 0 0 . 0 0 0 0 34 32 34 32 136 128 - 86 81 IA-clom 1270 a 35.56 34.77 0 0 0 0 0 0 0 0 13Altois %,Glom 0143: 1270 w w 4.00 35.56 2.55 5521 0 0 0 0 '0 0 0 0. 0 0 0 0 0 0 0 0 G �-G 4A5.2om 0.776 >' , w 21.56 19;31 0. 0:-. 0 .0 0 0 0 _ 0 P G . . ', 12C-Osw 16A36md. '. 0.091 0.032 - - 2.55 0.90 128 232 0 45 0 45 0 40 0 104 0 204 0 204 0 182 0 472 F 22A tpl 0.989 - 27.69 0.00 45 5 138 0 204 34 946 0 6 c) AED excursion -16 -85 Envelope loselgain 339 190 2978 3106 12 a) Infiltration 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Oocupants@ 230 0 0 1 230 Appliances(other 0 0 Subtotal (lines 6 to 13) 425 214 3571 . 3498 Lesse)temalload' 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal' 425 214 3571 3498 15 Ductloads 32% 49% 135 104 -32% 49% 1131 1704 Total room load 560 318 4702 5203 Air required ((*m) 28 141 232 232 Calculations aDDroved bvACCAto meet all reauirements of Manual J 8th Ed. wrilgMtsof!` . 2020-Jan-0816:20:47 Right-Sute®Uriversal 201919.0.07 RSU08101 Page 3 ...igWoftHVAC)THEGRAND CARLTON-1446-1MPACT.np Calc=W8 FrontDoorfaces: N rr vlr jhtsofr Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 Exposed wall 6.0 ft 47.0 It 3 Room height 8.0 It heaV000l SIB It heaftol 4, 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ftz 1.0 x 526.0 ft 526.0 ft2 Ty Construction U-value Or HTM Area (fl Load Area (it2) Load number (Btuh/P--°FF) (6luh/ilz) or , perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NP/S Heat Cool Gross N/P/S Heat Cool 6 W. 1--G 13AAocs 0.143 . n 4.00 2.55.. .0 0 0 0 255 217 -869 ' 552. :*4A5-26m- * . 0.770 '-' n - 21.56. ' 19:31 ' 0 :.' 0 -0 .0- 38 .. 0 .. -.815 . " 730 13AAocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 11 1A-c1om 11DO 1270 0.390 a a 35.56 10.92 8729 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D W: Y--G .13A-4ocs _ 13AAocs 0.143 0.143 se s ..4.00 4.00 -2.55 2.56 0 48 0 48 0 192 0 122 0 0 0 0 0• 0 0 0 1A-c1om 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 G 13A�as IA-clom 0143 1270 w w 4.00 36.56 2.55 5521 0 0 0 0 0 0 0 0. 206 0. 165 0 661. 0.• 420 0 4A5-2om . 12C-Osry 16A-30md 0.770 0.091 0.032 w . - - 21.56 2.65 - 0.90 19.31 128 :2.32 .0- 56 42; 0 56 42 0 143 38 0 72 - 97 41 0 526 41 0 526 880 0 471 : 788 0 1220 P C . F 22A-tpl 0.989 27.69 0.00 42 6 166 0 526 47 1302 0 6 c) AED excursion -22 668 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Intemalgains: Occupants@ 230 0 0 2 460 Appliancesvother 1 0 0 Subtotal(lines 6to13) 643 298 5994 5112 Less external load 0 0 0 0 Less transfer 0 0 0 0. Redistribution 0 0 0 0 14 Subtotal 643 -298 5994 5112 15 Duct loads 32% 49% 204 145 32% 49% 1899 2490 Total room load 846 443 1 1 7892 7602 Air required (dm) .42 20 390 338 Calculations approved byACCAto meet all requirements of Manual J 8thEd. -*j&- wragtatsalt- 2020-Jan-0816z0:47 Right-SuteO Uriversal 201919.0.07 RSU08101 Page 4 IghtsoltFNAMTHEGRAND CARLTON-1446-1MPACT.ap Calc=W8 Front Doorfaoes: N 'IrFwr gtattseft° Rights-M Works'heet Jove Entire House Date: QUICK CALCS, INC. sy. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@!AOL.COM 1 Room name FOYER M BATH. 2 ,EVosedwall 7.0 It 8.0 ft 3 Room height 8.0 ft heat/000l 8.0 it heaV000l 4 5 Room dimensions Room area. 1.0 x 60.0 ft 50.0 ftx 7.0 x 8.0 ft 56.0 ft= Ty Construction U-value Or HTM Area (1K) Load Area Load number (Bluh/ft=-°F) (Btuhfll�) or perimeter (ft) (BWh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs :'4A5-tom ` . 13A4o s 0.143 0.770 0.143 - n n a 4.00 2156. 4.00 2.55 .: 19:31 2.55 .8 . 0 48 8 ` 0 27 32. 0 108 20 . 0 69 0 0. 0 0 .0 0 0 :0 0 ' 0. . 0. 0 V�1 11A-clom 11 11DO 1270 0.390 a a 35.56 1022 8729 11.31 0 21 0 21 0 229 0 238 0 0 0 0 0 0 0 0 L--D W, L-G 13AAocs 13AAoos 1A-tom 0.143 0.143 1270 se s s ..4.00 4.00 35.56 2.55 2.55 34.77 0 0 0 0 0 0 . 0 0 0 0. 0 0 0 64 7 - 0 57 7 0 228 247 0 145 241 G 13A-46m 1Ac1om .0.143, 1270 w w 4.00 35.56 2.55 5521 0 , 0'. 0 0 0 0 0 0 0 0 0 0 .0 0 0 0 :4A5-26m; 12C-Osw .0.770 0.0.91 w 21.56 2.55 19.31 1.28 % 72 0 72 0 183 .0 92 0 0 0 0 0 0 0 0 P C 16A-30md 0.032 - 0.90 2.32 = 50 50 45 116 56 56 •50 .136 F 22A tpl 0.989 27.69 0.00 50 7 194 0 56 8 222 0 6 c) Am excursion -39 -38 Envelope lossigain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Ooaipants@ 230 0 0 0 0 Applianoes/other 0 0 Subtotal (lines 6 to 13) 913 529 885 516 Less exdamalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 S85 516 15 Duct loads 1 32% 49% 289 258 32% 49% 280 251 Total room load 1 1202 787 1166 768 Air required{dm) 59 35 58 34 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. -Fk- wrightsDftw 2020-Jan-081620.47 .4 A Right-Sdte@ Uriversal 2019 l9.0.07 RSU08101 Page 5 IgWoftHVAC1THEGRAND CARLTON-1446-IMPACT.np Calc = WS. Front Door faces: N . . Wrightsoft® Duct System Sll.immary o te: Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM P�roject intormation For: THE GRAND CARLTON IMPACT WYNNE DEVELOPMENT, FT. PIERCE, FL Extemal.static pressure Pressurelosses Available static pressure Supply/return available pressure Lowestfriction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 ih1100ft 1160 C(m 176 Supply Branch Detail Table Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cIrn Name Design (Btuh) Htg (din) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mati Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 OxO VIFx 22.4 115.0 st1 BEDROOM2 h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 . 0.300 6.0 Ox 0 VIFx 31.8 135.0 st2 BEDROOM•B h 3327 164 163 0.285 6.0 OxO VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 Ox 0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300. 7.0 Ox 0 VIFx 31.8 135.0 st2 GREAVDINING-A h 3946 195 169 0.300 7.0 OxO VIFx 31.8 135:0 st2 KrrCHEN c 3437 21 153 0.379 6.0 Ox 0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 Ox 0 VIFx 23.3 115.0 SO M. BATI+A h 768 58 34 .0 0 Ox 0 VIFx 0 0 WIC c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135A st2 Trunk Htg Clg Design Veloc Diam H x W . Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 721 672 . 0.285 918 12.0 0 x 0 VInIFIX st1 st1 PeakAVF 1043 1091 0.285 1020 14.0 0 x 0 vnIFIX wrightsof - 2620-Jan-081620:48 WgttSute®Uriversa1201919.0.07RSU08101 Pagel ...ightsoftHVACITHEGRAND CARLTON-1446-IMPACT.np Calc=MJ8 FrordDoorfaces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Cig (C11m) TEL (ft).. Design FR Veloc . (fpm) Diam (in) H x W (in) Stud/Joist .. Opening (in) Duct Mat Trunk rb1 Ox0 1160 1160 0 0 0 0. Ox 0 VIFx 4j1- wrighrSoft® 2020-Jarr081620:48 /4VC� —.1 un� wn4 m, RIgtt-Sate® Universal 201919.0.07 RSU08101. Page 2 IghtsoftWAMTHEGRAND CARLTON-1446=IMPACT.np Calc=MJ8 Front Door faces: N