HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida'Department of Business and Professional Regulation - Residential Performance. Method
ProjectName: WYNNE THE STERLING IMPACT
BuilderName: WYNNE DEVELOPMENT
Street: THE STERLING
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE , FL ,
PermitNumber:
Owner: ��
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Int Insul, Exterior
R=4.1 1250.00 ftz .
b. Frame - Wood, Adjacent
R=11.0 192.00 ftz
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ftz
5. Is this a worst case? Yes
10. Ceiling Types (1504.0 sqft.)
Insulation Area
a. UnderAttic (Vented)
R=30.0 1474.00 ftz
6. Conditioned floor area above grade (ftz) 1474
b. Knee Wall (Vented)
R=19.0 30.00 ftz
Conditioned floorareabelowgrade(ftz) 0
c. N/A
R= ftz
11. Ducts
R ftz
7. Windows(141.3 sqft.) Description Area
a. Sup: Attic, Rat: Attic, AH: Attic
6 175
a. U-Factor: Sgl, U=1.04 101.25 ftz
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ftz'
12. Cooling systems
kBtu/hr - Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ftz
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area. Weighted Average SHGC: 0.284
14. Hot water systems
a. Electric
Cap:50 gallons
8. Floor Types (1473.5 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ftz
9
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
Pstat
Total Proposed Modified Loads: 47.94
Glass/Floor Area: 0.096
PASS
Total Baseline Loads: 48.55
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered. by this
Code. may^
calculation indicates compliance
N
with the Florida Energy Code.
PREPARED Dy: - `
Before construction is completed
DATE: - Z 0= p
this building will be inspected for.
compliance with Section 553.908
hereby certify. that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Co e.��_>'4►?`
OWNER/��I�.
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification -by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection. Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1. 2).
4/20/2020 3:04 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE STERLING IMP Bedrooms: 2
Address Type:
StreetAddress
Building Type: User
ConditionedArea: 1474
Lot#
OwnerName:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
BuilderName: WYNNE DEVELOPMENT RotateAngle: 180
Street:
THE STERLING
Permit Office: ST. LUCIE COUNTY
CrossVentilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyType: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design
DailyTemp
V Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
.1474 11792
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BEDROOM
329 2632 No 0
1
1 Yes
Yes
Yes
2 WIC
63 504 No 0
1 No
Yes
Yes
3 M.BATH
56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN
192 1536 Yes 0
1 No
Yes
Yes
5 BATH
45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2
204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY
55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY,
42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING
488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# FloorType
Space Perimeter PedmeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 52 ft 0
329 ft2
____
0 1
0
2Slab-On-Grade Edge Insulation
WIC 1 ft 0
63ft2
____
0 1
0
3 Slab -On -Grade Edge Insulation
M. BATH 8 ft 0
56 ft2
___-
0 1
0
4Slab-On-Grade Edge Insulation
KITCHEN 1 ft 0
192ft2
_
0 1
0
5 Slab -On -Grade Edge Insulation
BATH 5 ft 0
45 ft2
_
0 1
0
6 Slab -On -Grade Edge Insulation
BEDROOM 2 32.2 ft 0
203.5 ft2
____
0 1
0
7SIab-On-Grade Edgelnsulation
ENTRY 7ft 0
55ft2
____
0 1
0
4/20/2020 3:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# FloorType Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood Carpet
8Slab-On-Grade Edge Insulation LAUNDRY 6ft 0
42ft2
----
0
1
0
9Slab-On-Grade Edge Insulation GREAT/DINING 46ft 0
488ft2
----
0
1
0
ROOF
/ Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 GableorShed Metal 1553 ft2
246 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1.474 ft2
N
N
CEILING
# CeilingType Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 UnderAttic(Vented) BEDROOM
30
Blown
329ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63ft2
0.1
Wood
3 UnderAttic(Vented) M.BATH
30
Blown
56ft2
0.1
Wood
4 UnderAttic(Vented) KITCHEN
30
Blown
192ft2
0.1
Wood
5 UnderAttic(Vented) BATH
30
Blown
45ft2
0.1
Wood
6 UnderAttic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55ft2
0.1
Wood
8 UnderAttic(Vented) LAUNDRY
30
Blown
42ft2
0.1
Wood
9 UnderAttic(Vented) GREAT/DINING
30
Blown
488ft2
0.1
Wood
10 Knee Wall (Vented) BEDROOM
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
Ft n
Ft
In
Aren
1 NE=>SW Exterior Concrete Block- Int Insul BEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
2 SW=>NE Exterior Concrete Block- Int Insul BEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.4
0
3 NW=>SE Exterior Concrete Block - Int Insul BEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
_ 4 SW=>NE Exterior Concrete Block- Int Insul M. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
5 NE=>SW Exterior Concrete Block- Int Insul BATH
4.1 5
0 8
0
40.0 ft2'
0
0
0.4
0
6 NE=>SW Exterior Concrete Block - Int InsuBEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
7 SE=>NW Exterior Concrete Block- Int InsuBEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
8 S=>N Exterior Concrete Block - Int InsuBEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.4
0
9 SW=>NE Exterior Concrete Block= Int InsuBEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
10 8E=>NW Exterior Concrete Block- Int lnsul ENTRY
4.1 6
0 8.
0
48.0 ft2
0
0
0.4
0
11 SW=>NE Exterior Concrete Block- IntInsul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.4
0
12 SW=>NE Exterior Concrete Block- Int Insul LAUNDRY
4.1 6
0 8
0
48.0.ft2
0
0
0.4
0
13 NE=>SW Exterior Concrete Block-IntlnsulGREAT/DINI
4.1 26
0 8
0
208.0ft2
0
0
0.4
0
14 NW=>SE Exterior Concrete Block- Int InsuIGREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.4
0
4/20/2020 3:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
v FORM R405-2017 INPUT SUMMARY: CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width
Height Sheathing Framing Solar Below
15 N=>S Garage Frame -Wood
KITCHEN 11 24 8
192.0ft2 0.23 0.4
0
DOORS
# Omt
DoorType
Space Storms
U-Value Width Height
Ft In Ft In
Area
1 SE=>NW
Insulated
ENTRY None
.39 3 1 6 8
20.6 ftz
WINDOWS
Orientation shown is the entered.orientation => changed to Worst Case.
Wall
# Ornt ID Frame
Panes
NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation IntShade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
. Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Yes 1.04 0.29 N
Yes 1.04 0.29 N
Yes 1.04 0.29 N
Yes 1.04 0.29 N
Yes 1.11 0.27 N
32.9 ft' 1 ft 0 in- 1 ft 5 in Drapes/blinds
6.9 ft' 1 ft 0 in 1 ft 5 in None
24.0 ft' 6 ft 0 in 1 ft 5 in None
37.5 ftz 1 ft 0 in 1 ft 5 in None
40.0 ftz 8 ft 0 in 1 ft 5 in Drapes/blinds
Exterior5
None
None
None
Exterior5
GARAGE
# FloorArea
CeilingArea Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1 315 ftz
315 ftz 24 ft
8 ft 11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50)
.000350 1375.7 75.53 142.04 .1233 7
HEATING SYSTEM
# System Type
Subtype Speed Efficiency
Capacity Block
Ducts
1 Electric Heat Pump/
Split Single HSPF:8.5
34.8kBtu/hr 1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1 CentralUnit/
Split Single SEER:15
34.8 kBtu/hr ch 0.85 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location EF Cap
Use SetPnt Conservation
1 Electric
None
Garage 0.97 50 gal 60.9 gal 120 deg None
4/20/2020 3:04 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
~ 'FORM R405-2017 INPUT SUMMARY. CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # CompanyName
System Model#
Collector Model# Area Volume
FEF
None None
ft2
DUCTS
— Supply—
-- Return —
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area
LeakageType
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic 6
175 ft2
Attic
65 ft2
DefaultLeakage .
Attic
(Default) c(Default) c
1 1
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
Jan H Feb
CoolingH.Jan
HeatinJan Feb
[[ ]] Mar
(X] Mar
Apr
May
Jun
Jul
n.AugSe
Oct
M'Nov
Nov
Dec
H
Venting Feb
[[XX]] Mar .
Apr
May
Jun
Jul
Aug
Sep
Oct
Dec
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78,
78
78
78
78
78
78 78
78
78
Cooling(WEH) AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating(WD) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68'
68
68
68
68 68
66
66
Heating(WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68.
.68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8lbs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(81bs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(81bs/sq.ft.
ft2
ft
0.3
BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8lbs/sq.ft.
ft2
ft
0.3
ENTRY
Default(8lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default Sibs/s .ff
ft2
ft
0.3
GREAT/DINING
4/20/2020 3:04 PM EnergyGauge® USA 6.0.02 (Rev: 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
y 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE:STERLING Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
U
Owner: Jurisdiction:
w
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any. dropped ceiling/soffit shall. be aligned with
The insulation in an dropped ceiling/soffit
/soffit
.
Y PP9
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access. openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of.the foundation and sill:plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment withthe air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of.floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Ds.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers. and tubs.
be insulated.
Electricaliphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers. shall only be
sprinklers
sealed. in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants. shall not be used to fill voids
between fire snrinkler cover olates and walls or cemlonns,
a. in addition, inspection of log walls shall be in accordance with the provisions of [CC-400.
4/20/2020 3:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
'" ' ' 2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts
R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts
R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system:
Capacity
34.8
a). Split system
SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package
SEER .
c) Ground/water source SEER/COP .
6. Conditioned floor area (sq. ft.)
6.
1474
d) Room unit/PTAC
EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient-(SHGC)
7b.
0.284
14. Heating system:
Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump
. HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance
COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas
AFUE
- b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace;. LPG
AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1: Wood frame (Insulation R-value)
2..Masonry.(Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a.' 0.0
9b.
9c.
10A1.
10A2. 4.1
10B1. 11.0
10B2.
15. Water heating system.
a) Electric resistance EF 0.97
b). Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 30.0 b) Cross ventilation No
11 b. c)-Whole house fan No
11c. 19.0 d) Multizone cooling credit
11d. No e) Multizone heating credit
0 Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
'certify that this home has complied with the Florida Building Code, Energy Conservation, through the 'above energy
saving features which :wi.11 be installed (or exceeded) in this. home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: THE STERLING\a �� v �� City/FL Zip: FT. PIERCE. FL
4l5ll�
4/20/2020 3:05:01 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1