Loading...
HomeMy WebLinkAboutProject InformationWlrightsoft, Project` Summary -Entire-House QUICK CALCS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 3494.6Phors: 772-466-6799 Fax: 772-.46676796 For. WYNNE DEVELOPMENT THE STERLING IMPACT, FT. PIERCE, FL Notes: Job: Date: By. Design Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside.db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 %. Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 18188 Biuh Structure 17877 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (O cfm) 0 Btuh Central vent (0 cfm) 0. Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23842 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Infiltration . Equipmen1 sensible load 25093 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2958 Btuh Ducts 2319 Btuh Central vent.(O cfm) 0 Btuh Heatingg .Coolingg (none) Area (fiz) 1474 1474 Equipment latent load 5277 Btuh Volume (V). 12227 12227 Airchanges/hour .0.45 0.23 Equipment Total Load (Sen+Lat) 30370 Btuh Equiu AVF (cfm) 92 47 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A" 030 Cond 25HBC536A" 030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 . Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual airflow 1160 cim Actual airflow .1160 cfm Air flow factor 0.049 cfm/Btuh Airflowfactor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 33 OF Backup: Input = 7 kW; Output = 23009 Btuh,100 AFUE Calculations approved byACCA to meet all'requirements of Manual J 8th Ed. -00- wP%2020-JarrOB 1624:12 Fart...is..r.mv.ewe.vas�fonro Right-s it o uriversal 201919.0.07 RSU08101 Page 1 s\WOgWoftFNAC1WYNNE-THESTERLING-IMPACT.tp CaIc=MJB Frorft Door faoes: N -n- wn'gtitsoW Right-M Worksheet Date: Entire House . Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS a,10L.COM 1 Room name Entice House MASTER BEDROOM 2 Exposed wall 1562 ft 52.0 It 3 Room height 8.3 ft d 8.0 It heat/000l 4 5 Room dimensions Room area 1473.5 fF 1.0 x 329.0 ft 329.0 f 2 Ty I Construction number U-value (Btuh/ft{°F) Or HUM (Btuhlft� Area or perimeter (ft) Load (BWh) oorperimeter (ft) (Btlih) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat" Cool 6 yJ ' G' 13AA- 1Ac1om 0143 1270 0.143 ' ne ne se 4.00 355G. 4.00 2.55 70.43.: 2.55 479 38 128 442 : 0 83 1768 1394 331 1124 2662 210 80 0 0 80 0 0 320 0 0 ' 204 0 0 /L13A-4ocs 11 1A-dom 11DO T13AAocs 13A-4ocs 1Ac1om 1270 0.390 0.143 0.143 1270 se se - s sw sir 35.56 10.92 4.00: 4.00 35.56 34.77 11.31 2.55 2.55 42.91 24 22 34 360 7 24 22 ". 34 353 5 848 236 136 1414 247 829 244 . 86 899 298 0 0 0 224 0 0 0 0 224 0 0 0 • 0 897 0 0 0 0 570 0 G D W V�/ --.G G 13A-4ocs 1Aclom 0143 1270 ' nw nw. 4.00, .35.56.1 2.55 A5.24 290 33 .217 0 867 1162 551 1478 112 33 79 0 318 1162 202 1478 `4A5-2om . 12C-0sw 16A30md 0.770 0.091 0.032 nw - - - 21.56 2.55 0.90 27.54 128 2.32 41' 192 1474 ' A 192 1474 880 489 1320 1124 246 . .3419 0 0 329 0 0 " `329 0 0 295 . 0 0 763 P C F 22A-tpl" 0.980 - 27.69 6.00 1474 156 4325 0 329 52 1440 0 fi c) AED excursion 784 680 Envelope loss/gain 15366 13954 4432 3897 12 a) Infiltration 2822 773 909 249 b) Room ventilation 0 0 0 0 13 Internal gains. Occupants@, 230 5 1150 2 460 Applianoesrother 2000 0 Subtotal (lines 6to 13) 18188 17877 5341. 4606 Less extemalload 0 0 0 0 Lesstransfer 0 0 0. 0 Redistribution 0 0 0 0 14 Subtotal 18188 17877 5341 4606 15 DUdloadS 1 31% 48% 5654 8536 31% 48%1 1660 2199 Total room load 23842 26413 7001 6805 Air required (dm) 1160 1160 341 299 r8gltits�s°tb Riga-Sute@Uriversal2019l9.0.07.RSU08101 s1WdgNsoftWAC1WYNNE-lHESTERUNG-IMPACT.np Calc=WB Frord Door faces: N 2020-Jan•081624:12 Page 1 -�- wriig asoft- Right J® Worksheet Job: Entire House Date: QUICK CALLS, INC. sy 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phore: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name WIC K BATH 2 Fposed wall 0 ft 8A ft 3 Room height 8.0 it heaUcool 8.0 ft heaftol 4 Room dimensions 7.0 x 9.0 ft 7D x 8D It 5 Room area 63D IF 56D ft= Ty Construction U-value Or HTM Area Load (flz) Load number (Btuhfll-°F) (BtuhAj2) or perimeter (ft) (Btuh) oorperimeter (ft) (Btuh) Heat Cool Grass NIPS Heat Cool Gross NOS Heat Cool 6 y! _ 13A4o6s 0.143 : ne 4.00 2.55 .0 0 0 0 0 0 0 0 ! G 1Ac1om ' _ 1270: ne, _ ' 35.56, 70.43 0 0 0 0' 0" •0 :'0 6 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 IA-c1om 1270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W. 13A4ocs 0.143 s . 4.00 . 2.55 0 0 0. 0 0 0 .0 0 t13A4ocs 0.143 sw 4.00 2.55 0 0 0 0 64 57 228 145 -G 1Aclom 1270 sw 35.56 42.91 0 0 0 0 7 5 247 298 13A46cs 0143 nw 4.09 2.55 0 '0 0 .0 0 0 .0 -'0 G 1A-clom 1270 : n'w.. 3656 4524 0 0 0 0 0 .0 . 0 AA5-2om .0.770; nw. 21:56 27.5.4 0 0 0 .0 0 0 .0 0. 0 P 12C-Osw 0.001 2.55 128 0 0 0 0 0 0 0 0 C ... A6A3(3md OD32 - 0.90 . -2.32 ,. 63 63 56 148 56 - •.56 50 130 F 22A tpl 0.089 - 27.69 0.00 63 0 0 0 56 8 222 0 6 c) AED excursion -2 225 Envelope loss(gain 56 145 747 798 12 a) Infilt mtion 0 0 140 38 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants.@ 230 0 0 0 0 Applianoeslother 1 0 0 Subtotal (lines 6 to 13) 56 145 887 836 Less wbmalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 145 887 836 15 Ductloads 31% 48%1 18 691 31% 48% 276 399 Total mom load, 1 74 214 1 1162 1235 Air required (cfm) 4 9 57 54 Calculations approved byACCAto meet all requirements of Manual J 8th'Ed. Ad- writg tsoT[ 2020-Jan•0816:24:12 . ► Right -SUM) Universal 20191.9.0.07. RSU08101 Page 2 s\WrigftS0It WA CAW YNNE-THE STERLING-IMPACTnp CaIc=MJB.Front Door faces: N - - wtighfsof - Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. ay: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICMALCS@/ OL.COM 1 Room name KrrCHEN BATH 2 EVoseciwall 0 ft 5D A 3 Room height 8.0 ft heaftol 8D It heallcool 4 5 Room dimensions Room area 1.0 x 192.0 ft 192D fl? 9D x 5.0 ft 45D IF Ty Construction number U-value (Btuh/IP-°F) Or HTM (Btuht" Area (ft-) or perimeter (ft) Load .(Btuh) Area or perimeter (ft) Load (Btuh) Heat Cool Gross Wro Heat Cool Gross NIPS Heat Cool 6 W c GI:IA-ddm 93A-flocs 13A-0ocs 0.143 1270 0.143 • ne "ne se 4.00 .'. 35.W 4.00 . 2.55- ' . 70.43 2.55 0 " 0: 0 o 0 0 0 0 0 0 a .0 0 40 0 0 40 0 0 160 :0 0 102 0 LD 11 1A-clom 11DO 1270 0.390 se se 35.56 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W,_. T-G .13A-0acs 13AAocs IA -Glom 0.1.43 0.148 1270 . s., sw sw 4.00 4.00 35.56 2.55 2.55 42.91 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 . . 0 0 0 0 0 0 13A-06cs _ 1Aciom 0.'M 1270 riw riw 4.06 35.56 2.55 4524 0 0 0 -. 0 0 0 0 0 0 0 0 .0 0 0 0 0 F C . • A'Worri:. 12C-Osw 16A-30md 0.770 0.091 0.032 nw - ' - . 21.56: 2.55 . 0.90 27.54 128 2.32 0. 64 192 0 64 192 0 163 172 .0 82 • 445 0 0 45 0 0 45 0 0 40 ' 0 0 104 F 22A tpl 0.989 - 27.69 0.00 192 0 0 0 45 5 138 0 6 c) AED exrursion -27 -2 Envelope lossigain 335 501 339 204 12 a) Infiltration 0 0 87 24 b) Room ventilation 0 0 0 0 13 Internal gains: Oocupants@ 230 0 0 0 0 Applianoeslother 2000 0 Subtotal (lines 6 to 13) 335 2501 .426 228 Less eAemalload 0 .0 0 0 Less transfer 0 0 0 _ 0 Redistribution 0 0 0 0 14 Subtotal 335 2501 426 228 15 Ductloads 31% 48% 104 1194 31% 48%1 133 109 FTTotal room load 439 3695 559 336 Alr required (cIm) 21 162 27 15 Calculations aDbroved WACCAto meet all reauirements of Manual J 8th Ed. ACCA Right-Sute®Uriversal 201919.0.07 RSU081012020-Jao-08.1624:12 . ..slWdghtsoftWAQWYNNE-THESTERLING-IMPACT.rnp Calc=MJ8 Front Doorfaces: N Page 3 wrightsoft" Right-M Worksheet Job:' Entire House Date: QUICK CALCS, INC. By 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phore:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name BEDROOM2 ENTRY 2 Exposed wall 322 ft 7.0 It 3 Room height 8.0 ft heaftol 8.0 ft heaV000l 4 5 Room dimensions Room area 1.0 x 203.5 It 203.5 T 1.0 x 55.0 It 55D fP Ty Construction U-value. Or HTM Area (T) Load Area Load number (Bluh/_-F) (BtuhfiF) or perimeter r (ft) (Btuh) or perimeter (ft) (Bfuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yJ 13AAocs 0.143 - he 4.00 2.55 128. 128 '513 326 0 0 6 o :1A,c1om 13A4ocs 1270 0.143 rid se 35.56. 4.00 70.43 2.55 : 0 80 0 56 0 225 0 143 0 48 0 26 :0 106 0 67 11 1Aclom 11DO 1270 0.390 se se 35.56 10.92 34.77 11.31 24 0 24 0 848 0 829 0 0 22 0 22 0 236 0 244 D W t13A4ocs G 13AAocs 1A-c1om 0.143 0.143 1270 `s sw sv 4.00 4.00 35.56 2.55 2.55 42.91 34 16 0 34 16 0 136 64 0 86 41 0 0 8 0 0 8 0 - 0 32 0 0 20 0 13A�ocs 1A-clom 0.143: 1270, riw nw 4.W .35.56 2.55 4524 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 --G c-G' P 0. . `,W-2om : 12C-Osv .16A�Orrd . 0.770 0.091 0.032 nw '- 21.56 2.55 0.90 27:54 128 2.32 0. 0 204 0 0 204 0 0 182 0 0 472 0 72 . 55 0 72 ' 55 0 183 49 . 0 92 . ' F. 22A-tp1 0.989 27.69 0.00 204 32 891 0 55 7 194 . .128 0 ' 6 c) AED e.,a.,, -24 -6 Envelope lossrgain 2859 1873 800 545 12 a) Infiltration 564 154 122 34 b) Roompentilation 0 0 1. 0 0 13 Internal gains: Oavpants@ 230 1 230 0 0 Applianoesrother 0 0 Subtotal (lines 6 to 13) 3422 2257 922, 579 Less exlemal load 0 0 0 0 Less transfer 0 0 0. 0 Redistribution 0 0 0 0 14 Subtotal 3422 .2257 922 579 15 Duct loads 31% 48% 1064 1078 31% 48%1 287 276 Total room load 4486 3335 1209 855 Air required (iim) 218 146 59 . 38 Calculations approved WACCA to meet all requirements of Manual J 8th Ed. -F d- wwrlsfvcsqst 2020-Jarr081624:12 Right-Stite@)Uriversa] 201919.0.07 RSU08101 Page 4 swrIghlsoftWAQWYNNE-THESTERUNG-IMPACTrp Calc=MJ8 Front Door faces: N -� ivdotwW Right:-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. ey 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 .Exposedwall 6D ft 46D ft 3 Room height 8.0 ft heaV000l 8.9 ft heaticool 4 5 Room dimensions Room area 7.0 x 6.0 It 42.0 fi? 1D x 488D ft 488D it2 Ty Constuction U-value or HTM Area Load s Load number (Btuhfft2-°F) (Btuhtflz) or perimeter r (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 13A-0bcs " 0143 ; ne 4.00. 2.55 .0 ' 0 0. 0 231 .194 '775 493. G ':1 Wrn 13A-4ocs 1276 0.143 ;: ne se 35.56: 4.00 ' : 70.43 2.55 ' 0 0 `. 0 0 0 0 0 0 38 0 ... ....0 0 1344 0 2662 0 11 1A-clom 11DO 1270 0.390 se se 35.56 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D W .. �13A-4ocs 13A-4ors 0.1.43 0.143 ` s sw 4.00 4.00 2.55 2.55 0 48 0 48 0 192 0 122 0 0 0 0 .0 0 0 0 G 1Aclom 1270 sN 35.56 42.91 0 0 0 0 0 0 0 0 -G �- 13A.46cs 1Ao1om 0143 12M `'riw nw 4.0 , 35.56 2.55 45.24 0 0: 0 0 0 0 0 0 178 0 137 0 549 0 , 349 0 '4AS2om 12C-Osw 16A-30md 0.770 0.091 0.032 nw - 21.56 2.55 0.90 27.64 128 '2.32 0 56 .42 0 56 42 0 143 38 0 72 97 41 0 488 0 0 '488 880 0 437 1124 0 1132 G P �C F 22A tpl 0.989 27.69 0.00 42 6 166 0 488 46 1274 0 6 c) AED excursion -3 -56 Envelope loss/gain 539 288 5259 5704 12 a) Infiltration 105 29 895 245 b) Room%entilation 0 0 0 0 13 Internal gains Occupants@ 230 0 0 2 460 Applianceslother 0 0 Subtotal (lines 6 to 13) 644 317 6154 6409 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 644 317 6154 6409 151 Dud loads 1 31% 48% 200 151 31% 48% 1913 3060 Total mom load 844 468 8067 9469 Air rouired (dm) 41 21 3931. 416 Calculations approved bVACCAto meet all requirements of Manual J 8th Ed. A -FW wrallan ol'r 2020-Jair081624:12 Aeek . " ° Riglt-Su*teO Uriversal 201919.0.07 RSU08101 Page 5 slWdgksoftHVAC1WYNNE-THESTERLING-IMPACT.np Calc=MJB Front Door faces: N ® Duct System-SummaryJob: - wrightsoft Date: Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799. Fax_772-466-6796 Email: QUICKCALCS ,AOL.COM f-roject Intormation For. WYNNE DEVELOPMENT THE STERLING IMPACT, FT. PIERCE, FL Extemal static pressure Pressurelosses Available static pressure Supply/return available pressure Lowestfricdon rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 'in H2O 0.284 in/10011 1160 cfm 176 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm Name Design (Btuh) Htg (cfm) Clg (drn) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 . Ox 0 VIFx 18.1 115.0 st1 BEDROOM2 h 4486 218 146 0.374 6.0 OxO VIFx 18.6 115.0 st1 ENTRY h 1209 59 38 0.510 4.0 Ox 0 VIFx 3.0 95.0 GREATIDINING c 4735 196 208 0.318 7.0 Ox 0 VIFx 22A 135.0 st2 GREAVDINING-B c 4735 196 208 0.307 7.0 OxO VIFx 28.1 135:0 st2 KITCHEN c 3695 21 162 0.375 7.0 OxO VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 Ox 0 VIFx 21.6 115.0 st1 M. BATH h 1162 57 54 0.366 4.0 OxO VI Fx 21.6 115.0 st1 MASTERBEDROOM-A h 3501 170 149 0.207 6.0 Ox0 VIFx 33.1 135.0 s12 MASTER BEDROOM-B h 8501 170 149 0.284 6.0 Ox0 VIFx 41.1 135.0 st2 WIC c 214 4 9 0.310 4.0 Ox 0 VIFx 26.3 135.0 st2 Supply Trunk Detail Table Trunk Htg. Clg Design, Veloc Diam H x W Duct Name Type (cfm) (drn) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 737 724 _ 0.284 938 12.0 0 x 0 VinlFlx st1 st1 PeakAVF 1101 1122 0.284 1050 14.0 0 X.0 VinIFIX Wrigh tso 2020-Jarr081624:13 jti <«urimn,e�.wm�r�•wnn Right-Sute®Uriversa1201919:0.07RSU08101 Pagel /�� ...slWrigHsoftWAMWYNNE-THE STERLING-IMPACT.nip Calc=MJ8 FrordDoorlaoes: N Return Branch Detail Table Name . Grille Size (in). Htg (ch) . Clg (cfm) TEL (ft) Design FR Veloc (fpm). Diam (in) H x W (in) Stud/Joist Opening (in) . Duct Mai Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 MFx wrightsoft, 2020-Jar-081824:13 .eerta•rwuea«.�.,�m,.•, MgttSUte® Uriversal 201919.0.07 RSU08101 Page 2 ACM ...s d&tsoftWAMWYNNE-1HESTERLING•IMPACT.np Calc=MJ8 FrontDoortaces: N