HomeMy WebLinkAboutTruss®=LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read given special attention by all persons installing trusses. SPACING NOTE ALL TRUSSES ARE TO BE SET AT 2'-0; ON CENTER EXCEPT AS NOTED MULTIPLE PLY TRUSSES MUST BE ASTENED TOGETHER PER ENGINEERIN BEFORE SETTING. REFER TO ENGINEERING DRAWING TO DETERMINE A& IF MULTIPLE PLY. i i DON'T LIFT TRUSSES WITH SPANS LONGER THAN it 30' BY THE PEAK. CONSULT BCSI 30' Span or less 30' to 60' Span 60 degrees Spree er Bar { or less _) /2 _10 ail •d Approx 2/3 to Tog Line span approx. Line 1/2 of span, REFER TO BCSI REFER TO BCSI ' Truss must be set this way if: crane used. Truss must be: set this way if crane used. Truss Is an example, your truss may not match. This is on example, truss may not match. Insist crane operator sets truss this way. Insist crone operator sets truss this way. I U REPRESENTS A i1ANGER ra 4 SEAT PLATES BY CHAMBERS INDICATES LOAD BEARING WALL REQUIRED BY TRUSSES SUPPLIED BY BUILDER AT A HEIGHT OF 8'-1" I ABOVE FINISHED FLOOR j 12 4.00 F_ CD 8r"1 e upset=1/4" heel=315/16" PLUMB CUT END 1' 2 x 4 Top Chord WALL HEIGHT V-1„ TYPICAL END DETAIL 12 4.00 I— to s- 2.00 12 " upset=1/4" heel=315/16" PLUMB CUT END 2 x 4 Top Chord WALL HEIGHT 8'-1" I i END DETAIL: A ARRANGE Wl H CRANE �I OPERATOR IN ADVANCE FOR A SPREADER BAR O 17'- 2,.I° IN LENGTH ® Do not stand on trusses until they are braced per BCSI properly nailed to straps & hangers P p Y ,.,I ® INS -------------------------- -------------------------------------\�_ �/ M ®\ '\ �' ®\® ,\ ®/ ®\� `\ sessiamim gqL oil to / 0PERm Milk , ON M --------- --- I�� ®IMIMIMIMIMIMIMIMIMIMIMI I I=I®�■� 1 31 FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED The legal description of the property where the busses will be Installed Is: The undersigned acknowledges and agrees: 1. Trusses will be made In strict accordance with Ihls base plocemenl diagram layout, which is the sole aulhodtyfor determining.successful fabrication of the hu ""S, 2. AN dimensions In this layout have been verified by the undersigned, .3. Unless written notice b provided by as rtlnod all to Chambers Truss within ten (10) days of delivery the undersigned agrees that no backoharges will be allowed..1, the event such written notice Is furnished C=r,6 Truss shall have three P) buaalInnass days In wmlch to begin repolre required, or to oubstitule other Wsses, at Chambsre op6a°n. 4, The undersigned acknowledges receipt of "BCSI 1.03" summary sheet by TPI & WrCA. 5. Delivery Is to job alto. It is the buyees'reaponsiblthy to make the Job alto suitable for delivery, Chambers Truss has the bole authority to determine the suitability of the Job site or 1 portion of the job site for delivery, Chambers Truss will be responsible for dump delhrery only. The buyer Is responsible for additional delivery expenses If Chambers Truss has to redellver bemuse Job she Is not prepared for delivery or buyer Is not prepared for delivery of trusses. Buyer Is responsible to Chambers Truss for towing costs duo to site conditions, 6. Pdoe as shown In paragraph 7 below, is subject to change If any changes are. made In ihli. layout. A $50 per hour fee for revisions may be charged by Chambers Tnlss, 7, This Is a PURCHASE ORDER to Chambers, Truss of the sum agreed to, or If no agreement a reasonable price, Invoice will be made on delivery and paid within terms of net on delivery. Invoice may, be made at scheduled date of delivery H buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers,Tryss ressonablo attorneys fee for collections In event of payment not timely made. 1.12 % per month service charge will be added for all sums not paidwithinterms. a. Signature or Initials anywhere on this sheet constitutes agreement to all terms herein. 9. In consideration of Chambers Truss extending credit for this material the undersigned unwnditionally guarantees payment when due of any and all Indebtedness owed to Chambers Trues by any entity receiving material and the undersigned agrees to pay such Indebtedness Including attorneys fees, If default In payment for material be made by the i recipient. 10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to herein, the. parties agree that the sole venue for any such action will be Saint L•ucle County, Florida. 11. Design responsibilities are per "National Standard And Recommended Guidelines On Responsibilities For Construction Using Metal Plate Connected Wood Trusses ANSVTPIANTCA 4 - 2002— DATEp_ ..... r SIGNED_ FORT_ Aspreaderbarmaybersgt{yWper'B=1-03"bsprarentidEuy&damn ,tie Multiple ply trusses must be fastened togtathar per engineering before they are set failure to do so can result In roof collapse. temporary and permanent bracing are required and can save life and property and Is the responsibility of the truss erector. Study the contents of the Information packet Included on delivery before setting trusses. Trusses mustbe setand braced par design to prevent iNury6 damage, Trusses must be set plumb and square Do not set bunks or stack of plywood, roofing material or any I other cohcentrated loads on trusses, this can cause collapse. Dp NOT SET TRUSSES USING THIS LAYOUT USE LAYOUT DELIVERED WITH TRUSSES' SET TRUSSES CHAMBERS TRUSS INC 3106 Oleander Avenue FortPlerce; Florida 34982-6423 800-551-5932 Fort Pierce 772-06-2012 Fax 772-465.8711 i Vero Beach T72368,e1Tq Stuart 772-2863302 re Stuart or. Archltec}•S representative• shop drawing approvalis NOT a ^double check" of the cantractor.l The. contractor Shelf remain responsible for checking field measrlrements an'd othercons}ruction criteria., Architect's approval covers general roof shape,. review of truss strapping, and loading I, on structure from gravity and uplift loads. and their resp cations. Approved By 92.0/93.2 MITEK 4.2 Date: DESIGN CRIT�f�r7�&gradenA A. County SAINT LUCIE Building Department SAINT LUCIE COUNTY a Wind Design Criteria ASCE 7-2010 .. k) Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10 o' � I p I Roofing Material Shingle or Shake �14 N Loading in PSF Roof R.D.L. H ' .c Top Chord Live 20 r � ; (Top Chord Dead 7 4.2 c ` �? Bottom Chord Live 10 Non -Concurrent Bottom Chord Dead 10 3 TOTAL Load 37 7.2 0.M Duration Factor 1.25 u is Wind Speed 165mph w N Top Chord C.B. Sheeting by builder. IL- Bottom Chord C.B. Sheeting by builder. Highest Mean Height 14'-0" Building Type ENCLOSED Building Category II:Non Restrictive Exposure Category C Barrier Island No Conforms to FBC 2017 R.D.L.=Restrainin Dead Load C.B.=Continuous Bracing Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Building Desi ner and/or En ineer of Record. Chambers Truss Inc. Drawing Name: M11323 LLI Scale: 1 /4 = 1' 72 total trusses, 13 different trusses MI 4: SAE ACAD: SAE Reviewed By - Date: 04/24/12 Revised:02/21118 FOR ��y d: 3/05/2020 REVIEWkWCE ® WYNNE BII�B�lr .� � DESCRIPT — I couluTY GARAC3) E RIGHT CARLTON CC PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE 13 TRUSS IDRAWING0 ARE ATTACHED TO LAYOUT M1 1323 It Ve/,le- Vt s f-Ae. a� MiTeke RE: M11323 M11323 Site Information: Customer: WYNNNE DEVELOPEMENT CORP Project Name: M11323 Lot/Block: Model: CARLTON Address: N/A City: PORT ST LUCIE Subdivision: State: FL MiTek USA, Inc. 6904 Parke East Blvd. Tampa, FL 33610-4115 General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 13 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# 1 T1988459 Truss Name A Date 8/31/2020 2 T19884597 A5 8/31/2020 FILE uupy 3 T19884598 A6 8/31/2020 4 T19884599 A7 8/31/2020 5 T19884600 A8 8/31/2020 6 T19884601 A9 8/31/2020 7 T19884602 GRA 8/31/2020 8 T19884603 10 GRB 8/31/2020 ,�IC R�Ml��f!!G® F�� T19884605 11 T19884606 J4 J6 8/31/2020 8/31/2020 CODE COMPLIANCE 12 T19884607 13 T19884608 J8 KJ8 8/31/2020 8/31/2020 ST. LUCIE COUNTY BCC This item has been electronically signed and sealed by Velez, Joaquin using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision `jtt 1111►1111�, based on the parameters provided by Chambers Truss. ��OPC U I N V,,,-,� Truss Design Engineer's Name: Velez, Joaquin My license renewal date for the state of Florida is February 28, 2021. Florida COA: 6634 97 No 68182 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. �:. STATE OF :BUJ; Iltlt Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 August 31, 2020 1 of 1 Velez, Joaquin Job Truss Truss Type Qty, Ply M11323 T19884596 M11323 A COMMON 9 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:27 2020 Page 1 I D:a3B4PavKnnZweXyJckSFBgyuFUN-bAjL909k_1 Hpv5SDpc_pEKrtnVLQuvtwTtLrJWzUUjw 1-0-0 6-7-13 12-4-13 17-0-0 21-71 27-4-3 34-0-0 5-0 0-0 6-7-13 5-9-0 4-7-3 4-7-3 5-9-0 6-7-13 0-0 �1 6 4.00 12 4x5 = 27 Scale = 1:57.8 17 '" 15 "" "' 14 '" 12 36 — 2x3 II 4x6 = 3x8 = 3x8 = 4x6 = 2x3 II 3x6 = LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/TPI2014 CSI. TC 0.39 BC 0.58 WB 0.65 Matrix -MS DEFL. in (loc) I/deft L/d Vert(LL) 0.32 14-15 >999 360 Vert(CT) -0.61 14-15 >670 240 Horz(CT) 0.12 10 n/a n/a PLATES GRIP MT20 244/190 Weight: 163 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-7-12 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-11-7 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 8) Max Uplift 2=-832(LC 10), 10=-832(LC 10) Max Grav 2=1362(LC 1), 10=1362(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-3419/2395, 3-5=-2771/2031, 5-6=-2770/2152, 6-7=-2770/2152, 7-9=-2771/2031, 9-10=3419/2395 BOT CHORD 2-17=-2132/3213,15-17=-2132/3213,14-15=-1269/2000,12-14=-2132/3213, 10-12=-2132/3213 WEBS 6-14=-635/983, 7-14=-313/362, 9-14=-689/499, 6-15=-635/983, 5-15=-313/362, 3-15=-689/499 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 13-7-3, Exterior(2)13-7-3 to 20-4-13, Interior(1) 20-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. This item has been 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = IO.Opsf. electronically signed and 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except (jt=lb) sealed by Velez, Joaquin, PE 2=832, 10=832. using a Digital Signature. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 47 lb up at Printed copies of this 15-0-0, and 50 lb down and 47 lb up at 19-0-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. document are not considered 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). signed and sealed and the signature must be verified LOAD CASE(S) Standard on any electronic copies. 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Joaquin Velez PE No.68182 Uniform Loads MiTek USA, Inc. FL Cert6634 =- Vert: 1-6=-54, 6-11=-54, 18-21=-20 Concentrated Loads (lb) 6904 Parke East Blvd. Tampa FL 33610 Vert: 26=-50(F) 27=-50(F) Date: April 3,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectam. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the febdoation, storage, delivery, erection and bracing of trusses and truss systems, see ANS117P/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884597 M11323 A5 SPECIAL 9 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:28 2020 Page 1 ID:2GIScwwyY5hnGhXVARzUkuyuFUM-3MHjMkAMIKQgXE1 PNJV2mXOxRucedNo4iX5oryzUUjv 1-0-0 7-8-5 10-6 4 17-0-0 20-4-8 26 4-0 34-0-0 5-0- -0-0 7-8-5 2-9-15 6-5-12 3-0-8 5-11-8 7-8-0 -0-0 �1 6 3x12 2.00 12 4.00 12 5x8 MT18HS 11 Scale = 1:59.8 13 12 5x12 = 2x3 II 3x6 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.85 Vert(LL) 0.76 14 >539 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -1.18 13-14 >344 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.60 Horz(CT) 0.36 10 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MS Weight: 155 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 1-7-8 oc puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 3-9-12 oc bracing. WEBS 2x4 SP No.3 *Except* WEBS 1 Row at midpt 6-14 6-14: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 8) Max Uplift 2=-803(LC 10), 10=-803(LC 10) Max Grav 2=1312(LC 1), 10=1312(LC 1) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5529/3776,3-5=-5164/3538,5-6=-5209/3667,6-7=-2424/1902,7-9=-2462/1813, 9-10=-3195/2210 BOT CHORD 2-14=-3466/5266, 13-14=-1305/2115, 12-13=-1948/2995, 10-12=-1948/2995 WEBS 3-14=-355/314, 5-14=-293/354, 6-14=-2175/3326, 6-13=-279/534, 7-13=-237/277, 9-13=-786/560, 9-12=0/269 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 13-7-3, Exterior(2) 13-7-3 to 20-6-4, Interior(1) 20-6-4 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=803,10=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MOW is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPli Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply T19884598 M11323 A6 SPECIAL 1 1 �M11323 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:29 2020 Page 1 I D:2GIScwwyY5hnG hXVARzU kuyuFU M-YYr6a4B_WeYX90cbwOOHJlx7ilyP Mm6DxBgy00zU Uju �1-0-0, 8-11-11 16-0-0 18-0-0 , 20-4-8 25-11-15 34-0-0 45.0-q -0-0 8-11-11 7-0-5 2-0-0 2-4-8 5-7-7 8-0-1 -0-0 �1 0 3x12 = 2.00 12 4.00 12 6xl0 MT18HS = 54 = 5x6 = 3x6 = Scale = 1:61.9 10-6-4 15-0-0 16-0- 20-4-8 25-11-15 34-0-0 10-6-4 4-5-12 0-0 4�-8 5-7-7 8-0-1 Plate Offsets (X,Y)— [2:0-1-15,Edge], [3:0-3-0,Edge], [5:0-5-0,0-1-13], [7:0-2-7,Edge], [9:0-0-6,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.81 Vert(LL) 0.69 14 >590 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.93 Vert(CT) -0.92 14-17 >443 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.86 Horz(CT) 0.34 9 file n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 157 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 *Except' TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. 3-5,6-7: 2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 5-14: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-169(LC 8) Max Uplift 2=-803(LC 10), 9=-803(LC 10) Max Grav 2=1312(LC 1), 9=1312(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 2-4=-5491/3336, 4-5=-5095/3071, 5-6=-2314/1551, 6-8=-2398/1533, 8-9=-3199/1981 BOT CHORD 2-14=-3040/5224,13-14=-1195/2361,12-13=-1123/2199,11-12=-1731/3001, 9-11=-1731/3001 WEBS 4-14=-492/513, 5-14=-1707/2959, 5-13=-405/196, 6-13=-179/522, 8-12=-893/660, 8-11=0/303 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This Item has been 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. electronically Signed and 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Sealed by Velez, Joaquin, PE 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide using a Digital Signature. will fit between the bottom chord and any other members. Printed copies of this 7) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. document are not Considered 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) signed and sealed and the 2=803, 9=803. signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc, FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and propedy Incorporate this design into the overall MiTek* building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing IV iTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS117PH quality Criteria, DSB-69 and SCSI Building Component 6904 Parke Fast Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job s Truss Type Ply M11323 T19884599 ]Tru M11323 A7 SPECIAL �Clty 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:30 2020 Page 1 ID: WSJgpGwal Ppeur6hk9UJG5yuFUL-OIPUnOCcHygOmYBnUkXWryTIF1145CtN9gaVwrcUUjt �1-0-0 8-10-10 14-01 20-0-0 25-11-15 34-0-0 a5 0-q -0-0 8-10-10 5-1-6 6-0-0 5-11-15 8.0-1 5x8 = 5x6 = Ann 3x12 = 2.00 12 2x3 11 10-6-4 14-00 204-8 25-11-15 34-0-0 10-6-4 3-5-12 654 8 5-7-7 8-0-1 Plate Offsets (X Y)— [2:0-1-15 Edge] [4:0-4-0 0-2-3] [7:0-0-2 Edge] LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 TCDL 7.0 Lumber DOL 1.25 BC 0.90 BCLL 0.0 Rep Stress Incr YES WB 0.95 BCDL 10.0 Code FBC2017rrP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 4-11: 2x4 SP M 30 REACTIONS. (size) 2=0-8-0, 7=0-8-0 Max Harz 2=-149(LC 8) Max Uplift 2=-803(LC 10), 7=-803(LC 10) Max Grav 2=1312(LC 1), 7=1312(LC 1) Scale=1:60.8 3x6 = DEFL. in (loc) I/deft Lid PLATES GRIP Vert(LL) 0.66 11 >616 360 MT20 244/190 Vert(CT) -1.1010-11 >369 240 MT18HS 244/190 Horz(CT) 0.34 7 n/a n/a Weight: 147 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-0-2 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5484/3370, 3-4=-5116/3126, 4-5=2229/1544, 5-6=-2448/1599, 6-7=-3169/1993 BOT CHORD 2-11=-3071/5219,10-11=-1590/2874,9-10=-173812968,7-9=-1738/2968 WEBS 3-11=-419/443,4-11=-1466/2647,4-10=-812/448,5-10=-205/487, 6-10=-785/575, 6-9=0/272 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=803,7=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 51IM020 BEFORE USE. Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall m p� building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply T19884600 M11323 A8 SPECIAL 1 1 �M`11123 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:31 2020 Page 1 , - I D:WSJgpGwa I Ppeur6 h k9Uj G5yuFU L-Uxzs_mCE2FoFOiI2R2lOAOTj6eKgj EWO UJ2-SHzU Ujs 8-8-4 1322 0-0 15-84 20-4-8 22-0-0 24-8-12 34-5-0 15-0t00-008-8-4 312 3-8-4 1 -0Q -7-8 2-8-12 9-34 -0 Scale=1:60.6 4.00 12 5x6 = 3x4 = 4 21 5 2x3 11 5x8 = 6 22 7 12 11 5x12 = 3x4 = 4x5 = 3x12 - 2.00 12 Plate Offsets (X,Y)— [2:0-1-15,Edge], [7:0-5-8,0-2-8] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (Icc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.78 Vert(LL) 0.65 12-13 >624 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -1.08 12-13 >379 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.69 Horz(CT) 0.33 9 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 154 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puriins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 3-11-11 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-129(LC 8) Max Uplift 2=-803(LC 10), 9=-803(LC 10) Max Grav 2=1312(LC 1). 9=1312(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5488/3444, 34=-5117/3183, 4-5=-3911/2497, 5-6=-2576/1770, 6-7=-2586/1779, 7-8=-2663/1762, 8-9=3021/1971 BOT CHORD 2-13=-3143/5224, 12-13=-1956/3292, 11-12=-1369/2481, 9-11 =-1 705/2827 WEBS 3-13=-396/420,4-13=-1028/1721,5-13=-300/797,5-12=-894/601, 6-12=-265/263, 7-12=-294/391, 7-11=-374/691, 8-11=-535/502 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 24-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ' This item has been 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. electronically Signed and 7) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify sealed by Velez, Joaquin, PE capacity of bearing surface. using a Digital Signature. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) Printed copies of this 2=803, 9=803. document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 511912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall my building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing iVliTe k• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884601 M11323 A9 HIP 1 1 Job Reference (optional) Unamners I cuss, Inc., Fort Pierce, FL 8.240 s Mar a NN MI t ek indusmes, inc. rn Apr 3 07:04:32 LULU rage i ID:_etcl cxC3ixVV?huls?ypJyuFUK-y7XEC6DspZw6OsKAc9Z_xNZ18W4CZ7Mfd83c?jzUUjr i1-0-0 6-7-15 10-0-0 15-2-14 20-4-0 24-0-0 27-4-1 34-0-0 a5-0-q 0-0 6-7-15 3 4-1 5-2-14 5-1-2 3 8-0 3 4-1 6-7-15 Scale = 1:58.6 4x4 = 2x3 II 4x8 = 4.00 12 3x4 = 4 24 525 26 6 27 7 rj1 0 15 t4 13 12 11 3x5 = 3x8 = 3x6 = 6x8 = 3x6 = 3x4 = 3x5 0 !9 IA 6 M LOADING (psf) SPACING- 2-0-0 cSl. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.35 Vert(LL) -0.18 11-21 >917 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.54 Vert(CT) -0.38 11-21 >432 240 BCLL 0.0 Rep Stress Incr YES WB 0.89 Horz(CT) 0.02 13 n/a n/a BCDL 10.0 Cade FBC2017/TPI2014 Matrix -MS Weight: 156 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-11-9 oc puriins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0, 13=0-8-0 Max Horz 2=109(LC 9) Max Uplift 2=-430(LC 10), 9=-249(LC 10), 13=-928(LC 10) Max Grav 2=685(LC 19), 9=386(LC 20), 13=1616(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1275/1025, 3-4=-913/708, 4-5=-829/705, 5-6=-565/807, 6-7=-565/807, 7-8=-104/278,8-9=-341/235 BOT CHORD 2-15=-836/1187, 13-15=-34/309, 11-13=-256/348, 9-11=-124/304 WEBS 3-15=425/501, 5-15=444/665, 5-13=-1215/1079, 6-13=-264/300, 7-11=-255/396, 8-11=461/521, 7-13=-837/703 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 24-13, Interior(1) 24-13 to 5-2-5, Exterior(2) 5-2-5 to 14-9-11, Interior(1) 14-9-11 to 19-2-5, Exterior(2) 19-2-5 to 28-9-11, Interior(1) 28-9-11 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ' This item has been 5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. electronically signed and 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) sealed by Velez, Joaquin, PE 2=430,9=249,13=928. using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884602 M11323 GRA HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 202U MiTek inoustnes, Inc. Fri Apr 3 07:64:33 202U rage i ID:_etCi cxC3ixVV?hu Is?ypJyuFUK-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq 1-0-0 8-0-0 11-1-1 17-0-0 18-6-0 22-2 6-0 -2 2-0 34-0-0 5-0- -0-0 8-0-0 3 1-1 5-10-15 1-6-0 3-8-2 3-9-14 8-0-0 0-0 THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 4x4 = 11 14 Scale = 1:60.6 3x5 — 3x6 II 3x6 = 6x8 = 3x6 = 6x8 = 4x4 = 6x8 = 8-0-0 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2017/TP12014 TRUSS DESIGNED FOR WIND LOADS IN THE PLANE OF THE TRUSS ONLY. FOR STUDS EXPOSED TO WIND (NORMAL TO THE FACE), SEE STANDARD INDUSTRY GABLE END DETAILS AS APPLICABLE, OR CONSULT QUALIFIED BUILDING DESIGNER AS PER ANSI/TPI 1. 18-6-0 26-0-0 7-4-15 7-6-0 [24:0-3-8 0-3-01,[27:0-3-8,0-3-01 CSI. DEFL. in (loc) I/deft Ltd TC 0.91 Vert(LL) 0.20 24-35 >914 360 BC 0.57 Vert(CT) -0.24 29-32 >552 240 WB 0.98 Horz(CT) 0.02 22 n/a n/a Matrix -MS PLATES GRIP MT20 244/190 Weight: 194 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc purlins. BOT CHORD 2x4 SP M 30 Except: WEBS 2x4 SP No.3 1 Row at midpt 8-21 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 7, 8, 19, 17, 14 REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2=-179(LC 6) Max Uplift All uplift 100 lb or less atjoint(s) except 2=-351(LC 8), 27=-1168(LC 8), 26=-1495(LC 8), 22=-625(LC 8) Max Grav All reactions 250 lb or less at joint(s) except 2=487(LC 17), 27=2232(LC 13), 26=2929(LC 14), 22=984(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-621/387, 3-5=-304/838, 5-7=-588/1209, 7-8=-588/1209, 8-12=-588/1209, 12-13=-588/1209, 13-15=-588/1209, 15-16=-588/1209, 16-18=-588/1209, 18-20=-2230/1280, 20-21=-2230/1280, 21-22=-2271/1263, 6-9=-126/305, 9-11 =-1 061363, 11-14=-193/412,14-17=-94/271,19-21=1431272 BOT CHORD 2-29=-247/677, 27-29=-189/540, 26-27=-779/446, 24-26=-411/653, 22-24=-1083/2108 WEBS 3-29=-500/1176,3-27=-1766/911, 5-27=-748/622,5-26=-546/351, 13-26=-946/617, 18-26=-2412/1474, 18-24=-846/1780, 21-24=-35/351, 4-5=-608/514, 19-20=-335/305, 14-15=-556/407, 11-12=-254/54 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. This item has been II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 electronically signed and 3) Provide adequate drainage to prevent water ponding. Sealed by .Velez, Joaquin, PE 4) All plates are 2x3 MT20 unless otherwise indicated, using a Digital Signature. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Printed copies of this 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide document are not Considered will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 351 lb uplift at joint 2, 1168 lb uplift at signed and sealed and the joint 27, 1495lb uplift at joint 26 and 625lb uplift at joint 22. Signature must be Verified 8) Girder carries hip end with 8-0-0 end setback. On any electronic copies. 9) Graphical puffin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Joaquin Velez PE No.68182 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at MiTek USA, Inc. FL Cart 6634 26-0-0, and 967 Ill down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the 6904 Parke East Blvd. Tampa FL 33610 responsibility of others. Date: 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). April 3,2020 andard ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/7P11 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884602 M11323 GRA HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8,240 s Mar 9 2UZU MITEK Industries, Inc. I-n Apr 3 UI:b4:33 2UZU rage z ID:_etC1 cxC3ixVV?huls?ypJyuFUK-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert:1-3=-54, 21-23=-54,29-30=-20,24-29=47(F=-27),24-33=-20, 3-11 =-1 26(F=-72), 11-21 =-1 26(F=-72) Concentrated Loads (lb) Vert: 29=-641(F) 24=-641(F) ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall Ergo building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Mel( is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply M11323 T19884603 M11323 GRB HIP 1 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:34 2020 Page 1 ID:SrRaEyyrgO4M78G4raW BLWyuFUJ-u We?doF7LAApF9UZjacSOoe_iJjP10by4SYi3czUUjp n1-0-0 8-0-0 13-8-0 17-0-0 20A-0 i 26-0-0 34-0-0 35-0-0, -0-0 8-00 5-8-0 3453-4-0 5.8-0 8-0-0 5x12 MT18HS = 4x10 = 4.00 12 2x3 II 4x6 = 2x3 II 3 23 4 5 6 7 24 4x6 = 3x6 II LOADING (psf) SPACING- 2-0-0 TOLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2017/TP12014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 4-14,7-13: 2x6 SP No.2 5x6 = 6x12 = 6x12 = 5x6 = 5x12 MT18HS = 3x6 II Scale = 1:58.6 4x6 = CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TC 0.80 Vert(LL) 0.2216-19 >999 360 MT20 244/190 BC 0.68 Vert(CT)-0.3016-19 >820 240 MT18HS 244/190 WB 0.90 Horz(CT) 0.06 9 n/a n/a Matrix -MS Weight: 153 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-1-14 oc pudins. BOT CHORD Rigid ceiling directly applied or 5-3-14 oc bracing. WEBS 1 Row at midpt 3-14, 8-13, 6-13 REACTIONS. (size) 2=0-8-0, 13=0-8-0, 9=0-8-0 Max Horz 2=90(LC 7) Max Uplift 2=-853(LC 8), 13=-2590(LC 8), 9=-345(LC 8) Max Grav 2=1451(LC 13), 13=4743(LC 15), 9=528(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3625/1950, 3-4=-2080/1236, 4-6=-2080/1236, 6-7=-1296/2589, 7-8=-1296/2589, 8-9=-751 /370 BOT CHORD 2-16=1729/3460, 14-16=-1753/3525, 11-13=-262/733, 9-11=-241/668 WEBS 3-16=-435/1209,3-14=-1552/774,4-14=-837/691,7-13=-878/713,8-13=-3635/1919, 8-1 1=-432/1204,6-14=-1453/2814, 6-13=-3198/1807 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise Indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 853 lb uplift atjoint 2, 2590 lb uplift at joint 13 and 345 lb uplift at joint 9. 8) Girder carries hip end with 8-0-0 end setback. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at 26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-8=-131(F=-77), 8-10=-54, 16-17=-20, 11-16=49(F=-29), 11-20=-20 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MITektall connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall MiTek* building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the " fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS/?P/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply M11323 T19884603 M11323 GRB HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fart Pierce, FL LOAD CASE(S) Standard Concentrated Loads (Ib) Vert: 16=-641 (F) 11=-641(F) 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 2 ID:SrRaEyyrg04M78G4raW BLWyuFUJ-MiCNg7Gl6UIgtJ31HH7hYOB9Sj3emSr6J6HGb2zUUjo A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5ff912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall Sat building design. Bracing Indicated is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSBTPH Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Ply M11323 T19884604 M11323 J2 �Qty MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 1 ID:x1?zSlzTbJCDI IrGPH1 QukyuFUI-MiCNg7Gl6UIgtJ31HH7hYOBJ7jCDmgz6J6HGb2zUUjo -1-0-0 2-0-0 1-0-0 2-0-0 3x4 = 2-0-0 Scale = 1:7.8 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.07 Vert(CT) -0.00 7 >999 240 BCLL 0:0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MP Weight: 8 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc pudins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=67(LC 10) Max Uplift 3=-28(LC 10), 2=-136(LC 10), 4=-3(LC 7) Max Grav 3=39(LC 15). 2=141(LC 1), 4=31(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28lb uplift at joint 3, 136 lb uplift at joint 2 and 3 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date; April 3,2020 ®WARNING - Verlfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall Inv 11' building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-69 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply �M11323 T19884605 M11323 J4 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1 ID:PDYLfd_5MdK4MSQTz7ZfRxyuFUH-gvml2TGNtoQXUTexr7ew5DjQW7UmV7DFYm1 p8UzUUjn -1-0-0 4-0-0 1-0-0 4-0-0 Scale = 1:11.1 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.02 4-7 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MP Weight: 14 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc pudins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=104(LC 10) Max Uplift 3=-80(LC 10), 2=-161(LC 10), 4=-7(LC 10) Max Grav 3=90(LC 1), 2=207(LC 1), 4=69(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 3, 161 lb uplift at joint 2 and 7 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verily the applicability of design parameters and properly incorporate this design Into the overall Nat building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, OSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Ply T19884606 M11323 J6 MONO TRUSS �Qty 8 1 �1011323 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 1-0-0 3x4 = 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 01:54:36 2020 Page 1 ID:tP6jtzj7xSx_c fXi4uz9yuFUG-gvml2TGNtoQXUTexRew5DjR?7MUV7DFYm1p8UzUUjn Scale = 1:14.6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.36 Vert(LL) 0.11 4-7 >629 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.83 Vert(CT) -0.12 4-7 >617 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 20 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=142(LC 10) Max Uplift 3=-131(LC 10). 2=-194(LC 10), 4=-8(LC 10) Max Grav 3=145(LC 1), 2=279(LC 1), 4=102(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 3, 194 lb uplift at joint 2 and 8 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chard members only. Additional temporary and permanent bracing MiTek♦ I s always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPH Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply M11323 T19884607 M11323 J8 MONO TRUSS 20 1 Job Reference (optional) Chambers Truss, Inc., Fart Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:37 2020 Page 1 ID:tP6jtz_j7xSx_c fXi4uz9yuFUG-J5K7FpH7d5YO6dD8Oi99eRGYgXquEaTPmQmNgxzUUjm 1-0-0 8-0-0 1-0-0 8-0-0 Scale=1:17.4 3x5 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.62 Vert(LL) 0.26 4-7 >367 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.30 4-7 >319 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MP Weight: 26 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD 2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=180(LC 10) Max Uplift 3=-175(LC 10), 2=-228(LC 10), 4=-15(LC 10) Max Grav 3=188(LC 1), 2=352(LC 1), 4=145(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 24-13, Interior(1) 2-4-13 to 3-1-13, Exterior(2) 3-1-13 to 7-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 175 lb uplift at joint 3, 228 lb uplift at joint 2 and 15 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6834 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 6/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not • a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall ■•Y■ building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Ply T19884608 M11323 KJ8 MONO TRUSS �Qty 4 1 �M`11323 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:38 2020 Page 1 ID: Lcg54J?Lu Ea ncmZr4Qb7 W Myu FU F-n HuVT9ldOPg Fkno KyPgOAeooawBGzwZY?4 WwC NzU Uj I -1-SO 7-3-4 i 11-3-0 7-3-4 3-11-12 Scale = 1:20.3 3x4 = 5 3x4 = LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 SPACING- 2-0-0 CSI. Plate Grip DOL 1.25 TC 0.29 Lumber DOL 1.25 BC 0.30 Rep Stress Incr NO WB 0.46 Code FBC2017/TPI2014 Matrix -MS REACTIONS. (size) 4=Mechanical, 2=0-11-5, 6=Mechanical Max Horz 2=244(LC 8) Max Uplift 4=-205(LC 8), 2=-305(LC 8), 6=-286(LC 8) Max Grav 4=245(LC 13), 2=466(LC 1), 6=590(LC 13) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1151/523 BOT CHORD 2-7=687/1126, 6-7=-687/1126 WEBS 3-7=0/330, 3-6=-12361755 DEFL. in (loc) I/deft Lid Vert(LL) 0.07 7-10 >999 360 Vert(CT) -0.12 7-10 >999 240 Horz(CT) 0.02 6 n/a n/a 11-3-0 3-11-12 PLATES GRIP MT20 244/190 Weight: 44 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 8-9-6 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 205 lb uplift at joint 4, 305 lb uplift at joint 2 and 286 lb uplift at joint 6. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54 Trapezoidal Loads (plf) Vert: 2=0(F=27, B=27)-to-4=-152(F=-49, B=-49), 8=0(F=10. B=1 0)-to-5=-56(F=-1 8, B=-18) This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall lag' building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iVliTe k• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 quality Criteria, DSB-99 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Symbols PLATE LOCATION AND ORIENTATION Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. Ole For 4 x 2 orientation, locate plates 0- ti+s' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. " Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TP11: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 2 3 TOP CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MiTek@ All Rights Reserved MiTek � MiTek Engineering Reference Sheet: Mll-7473 rev. 5/19/2020 ® General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSIfrPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSVTPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20, Design assumes manufacture in accordance with ANSIrFPI 1 Quality Criteria. 21.The design does not take into account any dynamic or other loads other than those expressly stated.