Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
w rightow, Project Summary Job: : Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone:772-466.6799 Fax 772-466-6796 Email: QUICKCALCS@,4OL.COM For: WYNNE DEVELOPMENT THE STERLING IMPACT, FT. PIERCE, FL Notes: \��/ . F� c9 �, � Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db. 70 OF Inside.db 75 OF Design TD 28 OF Design TD 15 OF Dailyrange L . Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18188 Btuh Structure 17877 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23842 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration . Equipmensensible load 25093 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolin�gg (none) Area (ftz) 1474 1474 Equipment latent load 5277 Btuh Volume (ft3). 12227 12227 Air changes/hour .0.45 0.23 Equipment Total Load (Sen+Lat) 30370 Btuh Equiv AVF (cfm) 92 47 Req. total capadty at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A O30 Cond 251-1130536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating input. Sensible cooling 24360 Btuh Heating output. 34600. Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling _ 34800 Btuh Actual airflow 1160 cfrn Actual airflow .1160 cfrn Airflowfactor 0.049 cfrnBtuh Airflowfactor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 33 OF Backup: Input = 7 kW, Output = 23009 Btuh,100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. A& wright'soft- 2020-Jar>-081624:12 .naw+i,awm..waa.wsocy.ro Right -Sate® Uriversal201919.0.07 RSU08101 Page 1 §NWrigHsoitHVAQWYNNE-THESTERLING-IMPACT.np Calc=MJ8 FraMDoorfaces: N - an►a gtitsow Right-M Worksheet Job: Date: Entire House D QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone:772-466.6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 E)posed wall 1562 ft 52.0 It 3 Room height 8.3 It d 8.0 ft heat/000l 4 5 Room dimensions Room area 1473.5 ft" 1.0 x 329.0 It 329.0 it2 Ty Construction number U-value (Btuh/ftz-°F) Or HTM (BtuhhF) Area or perimeter (ft) Load (Btuh) oorperimeter (ft) (BWh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 w 13A-4ors 1A-clom 13A-4ocs 0.143 1270 0.143 - ne 'ne se 4.00 35:56 4.00 . 2.55. 10.43 2.55 419 -38: 128 442 0 83 1768 1344 331 1124 2662 210 80 0 0 80 .0 0 320. 0 0 204 . 0 0 G 11 IA-clom 11130 .13AAocs 13AAocs 1A-ciom 1270 0.390 0.143 0.143 1270 se se . s sw sw 35.56 10.92 .4.00. 4.00 35.56 34.77 11.31 2.55 2.55 42.91 24 22 34 360 7 24 22 34 353 5 848 236 136. 1414 247 829 244 86 899 298 0 0 0 224 0 0 0 0 224 0 0 0 -.0 897 0 0 0 0 570 0 D >W . T-G 13AAocs 1A-clom 0.143 1270 nw , nw 4.001 35.56 -2.55 : 4524 290 33 .217 0 867 1162 551 1478 112 33 79 0 318 1162. . 202 1478 `4A5.2om _ 12C-Osw 16A30md 22A-tol 0.770 0.091 0.032 0.980 nw - - 21.56 2.55 0.90 27.69 27.54 128 2.32 0.00 41 192 1474 1474 0 192 1474 156 . 880 489 1320 4325 1124 246 . 3419 0 0 0 329 329 0 0 `329 52 0 0 295 1440 . 0 0 763 0 P 'C F 6 c) AED excursion 784 680 Envelope loss/gain 15366 13954 4432 3897 12 a) Infiltration 2822 773 909 249 b) Room ventilation 0 0 0 0 13 Internal gains: Oavpants@_ 230 5 1150 2 460 Appliances(other 2000 0 Subtotal (lines 6 to 13) 18188 17877 5341 4606 Lesse)(temalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18188 17877 5341 4606 15 Ductloads 31% 48% 5664 8536 31% 48% 1660 2199 Total room load 23842 26413 7001 6805 Air required (dm) 1 1160 1160 341 299 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. w Wrig/s spa tta Rig Fk-SiiteO Uriversa1201919.0.07 RSU08101 2020-Jan-081624:12 .a Page 1 .:slWdgtdsoftM/AC\WYNNE-TtiESTERLING-IMPACT.np CaIc=MJB Front Door faces: N - wrighuoft- Right-J® Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 More:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WE M BATH 2 3 4 5 E)posed wall Room height Room dimensions Room area 0 ft 8.0 ft heatlobol 7.0 x 9.0 ft 63.0 W 8.0 ft 8.0 ft heatl000l 7.0 x 8.0 ft 56.0 fe Ty Construclion number U-value (BWhfiF--°F) Or HTM (BWhA11) Area or perimeter (ft) Load (Btuh) orsperimeter (ft) (Bhch) Heat Cool Gross NIPS Heat Cool Gross N/PIS Heat Cool 6 11D G G L 13AAocs AX.dom : - 13A4ocs 1A-clom 11DO :1M4ocs IA-clom 13A-4ocs. IA-c1om 4A5-2om 12C-0sN 16A-30md 22A tDI 0143: 1270 0.143 1270 0.390 0.143 0.143 1270 0143 1270 0.770 0.091 0.032 am ne r` ne.: se se se s sN sw nW nw, nw: - - 4.00. •' 35.56, 4.00 35.56 10.92 4.00 4.00 35.56 . 4.00 . 35.56 2136 2.55 0.90 27.69 2.55 70.43 2.55 34.77 11.31 2.55 2.55 42.91 2.55 4524 27.54 128 2.32 0.00 0 0'. 0 0 0 0 0 0 0 0' 0: 0 •.63 63 0 0 0 0 0 0. 0 0 0 0 0 0 . 63 0 0 0 0 0 0 0. 0 0 0 0 0 0 56 0 0 .0 0 0 0 0 0 0 .0 0 0 0 . 146 0 0 0 0 0 0 0 64 7 0 . 0 0 0 56 56 0 0 0' 0 0 0 57 5 0 0 0 0 ' .56 8 0 0 0 0 0 0 228 247 0 A. 0 0 50 222 0 . 0 0 0 0 0 145 298 0 a 0 0 130 0 W. 'L13A-4ocs -G P C .. F 6 c) AED excursion -2 225 Envelope losslgain 56 145 747 798 12 a) Infiltration 0 0 140 38 b) Room ventilation 0 0 0 0 13 Internal gains: Oocupants.@ 230 0 0 0 0 Appliano Bother 0 0 Subtotal (lines 6 to 13) 56 145 887 836 Lesse:memalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 145 887 836 15 Ducttoads 31% 48% 18 69 31% 48% 276 399 Total room load 74 214 1162 1235 Airrequired (dm) 4 9 57 54 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. - wrigh>rsofC" 2020-Jan-081624:12 Riglt SuteO Uriversal 201919.0.07 RSU08101AWK Page 2 ..slvvdgNsoftHUAC1WYNNE-THESTERLING-IMPACT.np Calc=NUB Front Door faces: N - vwrightsow Right-M Worksheet Jam: Entire House °ate' ` By. QUICK CALLS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772-466.6799 Fax: 772-466.6796 Email: QUICKCALCS@AOL.COM 1 Room name KITCHEN BATH 2 Fx;xosed wall 0 It 5.0 A 3 Room height 8.0 It heaUcool 8D ft heaf/000l 4 5 Room dimensions Room area 1D x 192.0 It 192D fl2 9.0 x 5D It 45D fP Ty Construction U-value Or HTM Area (tt2) Load Area (ft2) Load number (Btuhlft2-9 (Btuhtfl or perimeter (ft) (Stuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 G 13A flocs 0.143 : • ne 4.00 Z55 - .0 0 0 0 40 40 166 102 :1A�1om " 13A4ocs 1270 0.143 >'he se 3556' 4.00 70:43 2.55 0 0 : 0 0 0 0 0 0 0 0 . 0 0 A 0 . ' 0 0 11 IA-clom 11DO 1270 0.390 as se 35.56 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W. W -G .13A-4ocs 13A4ois 1Ac1om 0.143 0.143 1270 s sw suv 4.00 4.00 35.56 2.55 2.55 42.91 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 �{-- G 13A-0oc; 1Xc1om 0.143- 1270 nw • hw 4.06 35.66 ,. 2.55 - "4524 0 0-- 0 ..0 0 0 0 0 0 0 0 .0 0 0 0 0 I . AA5-2om: 12C-Osw 0.770 0.091 nw - . 21.56, 2.55 27.54 128 0. 64 0 64 0 163 .0 82 0 0 0 0 0 0 0 0 P C . ' 16A30md 0.032 - - 0.90 2.32 192 192 172 445 45 -45 40 104 F 22A-tpl 0.989 - 27.69 0.00 192 0 0 0 45 5 138 0 6 c) AED excursion -27 -2 Envelope loselgain 335 501 339 204 12 a) infiltration 0 0 87 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoeslother 2000 0 Subtotal (lines 6 to 13) 335 2501 .426 228 Less eAemal load 0 .0 0 0 Lesslransrer 0 0 0 _ 0 Redistribution 0 0 0 0 14 Subtotal 335 2501 426 228 15 Ductloads 31% 48% 104 1194 31% 48% 133 109 Total room load 439 3695 559 336 Air required (crm) 1 1 211 162 27 15 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wa-igl�tsol l� 2020-Jan-081624:12 RightSute®Uriversal20191.9.0.07RSU08101. Page3 .:.slWrighsoftWAQWYNNE-THE STERLING-IMPACT.rp Calc=W8 Front Door faces: N - wrightwft, Right-J® Worksheet Job: Entire House Date` QUICK CALLS, INC. By- 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 PMre:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM2 ENTRY 2 3 Exposed wall Room height 322 ft 8.0 it heaftol 7.0 It 8D It heaUcool 4 5 Room dimensions Room area 1.0 x 203.5 ft 203B ft' 1.0 x 55.0 ft 55.0 f12 Ty Construction number U-value (Btuh#VF) Or HTM (Btuhlfl=) Area or perimeter r (ft) Load (Btuh) s or perimeter (ft) (Btuh) Heat Cool Gross NOS Heat Cool Gross N/P/S Heat Cool 6 V 13AAocs `.1A�1om 0:143 he 4.00 2.55 128 128 513 . ' 326 0 0 6 .0 13AAocs 1270 0.143 rie se 35.56: 4.00 70.43 2.55 0 80 ` 0 56 .0 225 .0 143 0 48 0 26 :0 106 0 67 V�1 11 1Ao1om 11DO 1.2 0.390 se se 35.56 10.92 34.77 11.31 24 0 24 0 848 0 829 0 0 22 0 22 0 236 0 244 I;_G D W ' Y-G 13A-flocs 13AAocs 1A-c1om 13A IA-c1om 0.143 0.143 1270 . 0143 1270. s sw sw : ' riw nw 4.00 4.00 3556 4.00' 35.56 2.55 2.55 42.91 2.55 '46.24 34 16 0 0 0 34 16 0 0 0 136 64 0 0 p 86 41 0 0 0 0 8 0 0 0 0 8 0 0 p 0 32 0 ' -0 0 0 20 0 0 0 F 0. . F. 4A5-2om . 12C-0sw -16A30rrd 22A tol 0.770 0.091 0.032 0,989 , nw 21.56 2.55 0.90 27.69 27.54 128 '2.32 0.00 0. 0 204 204 0 0 204 32 0 0 182 891 0 0 472 0 0 72 55 55 0 72 55 7 0 183 '49 194 ,. 0 92 .128 0 6 c) AED excursion -24 -6 Envelope loss(gain 2859 1873 800 545 12 a). Infiltration 564 154 122 34 b) Room ventilation 0 0 0 0 13 Internal gains: Oocipants@ 230 1 230 0 0 Applianceeother 0 0 Subtotal (lines 6to 13) 3422 2257 922, 579 Less external load 0 0 0 0 Lesstransfer 0 0 0. 0 Redistribution 0 0 0 0 14 Subtotal 3422 .2257 922 579 15 Ductloads 31% 48% 1064 1078 31% *% 287 276 Total room load 4486 3335 1200 855 Air required (drn) 218 146 59 38 Calculations approved WAWA to meet all requirements of Manual J 8th Ed. wwSgftetScwk- 2020-Jan-081624:12 -7 Right -Sate® Universal 201919.0.07 RSU08101 Page 4 slWdghlsoftWAQWYNNE-THESTERLING-IMPACT.np Calc=MJ8 FrontDoorfaces: N Aj- wright Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. ay: 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 F)posed wall 6D ft 46.0 ft 3 Room height 8.0 ft heaU000l 8.9 ft heaU000l 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 T 1D x 488.0 ft 488D IF Ty Construction U-value Or HTM Area (T) Load Area (ft� Load number (BbjKd2-°F) (BluhfiF) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 L-'G 13446cs " :1Ac1om 0143 . 1270 : ne : ne` 4.00. 35.56. 255 ' 70.43 0 '0- 0 0 0 0 0 0 231 38 194 0 775 M" ' _ 493. 2662 G 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11 IA-clom 11DO 1270 0.390 se se 35.56 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D W.. 13A4ocs 0.143 s. 4.00 2.55 0 0 0 0 0 0 0 0 Y--G 13AAocs 0.143 sw 4.00 2.65 48 48 192 122 0 0 0 0 1A-clom 1270 sw 35.56 42.91 0 0 0 0 0 0 0 0. G 13A1}ocs ,1A�1orn 0143 1270 `' riw -nw 4`.00 35:56 2.55 4524 0 0. 0 0 0 0 0 0 178 0 137 0 549 0 349 0 AA5-2om 0.710 nw 21.56 27.54 0 0 0 0 41 0 880 1124 P 12C-0sw 0.091 - 2.55 128 56 56 143 72 0 0 0 0 C = .16A30md 0.032 - 0.90 2.32 42 42 38 97 488 ' '488 437 1132 F 22A-tol 0.989 - 27.69 0.00 42 6 166 0 488 46 1274 0 6 c) AED e)mrsion -3 -56 Envelope loss(gain 539 288 5259 5704 12 a) Infiltration 105 29 895 245 b) Roomventilation. 0 0 0 0 13 Internal gains. Occupants@ 230 0 0 2 460 Applianoss(other 1 0 0 Subtotal (lines 6to13) 644 317 6154 6409 Less e)clemal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 644 317 6154 6409 15 Ductloads 31% 48% 200 151 31% 48% 1913 3060 FTTotal room load 844 468 8067 9469 Air required (dm) 41 211 393 416 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. wraghfisewt- 2020-Jan•081624:12 A CCK Pjght-Sute®Uriversal 201919.0.07 RSU08101 Page 5 s\WrightsoftWAMWYNNE-THE STERLING-IMPACTrLp Colo =MJ8 Front Door faces: N - wrightsoft° Duct SystemSummalry o te: Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946Phone: 772-466-6799 Fax.772-466-6796 Email: QUICKCALCS@,10L.COM For: WYNNE DEVELOPMENT THE STERLING IMPACT, FT. PIERCE, FL External static pressure Pressure losses Available static.pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm 176 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250/0.250 in H2O 0.284 in/100ft 1160 cim Name Design (13tuh) Htg (Cfm) Cig (Cfm) Design FR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg:Egv Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 . Ox 0 MFx 18.1 115.0 st1 BEDROOM2 h 4486 218 146 0.374 6.0 Ox0 VIFx 18.6 115.0 st1 EMRY h 1209 59 138 0.510 4.0 OxO VIFx 3.0 95.0 GREAVDINING c 4735 196 208 0.318 7.0 Ox 0 VIFx 22A 135.0 st2 GREAVDINING-B c 4735 196 208 0.307 7.0 Ox 0 VIFx 28.1 135.0 st2 KrrCHEN C 3695 21 162 0.375 7.0 Ox 0 VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6:0 Ox 0 VIFx 21.6 115.0 st1 M. BATH h 1162 57 54 0.366 4.0 Ox 0 VI Fx 21.6 115.0 st1 MASTERBEDR00%A h 3501 170 149 0.207 6.0 Ox0 VIFx 33.1 135.0 st2 MASTERBEDROOM-B h 8501 170 149 0.284 6.0 Ox0 VIFx 41.1 135.0 st2 WIC c 214 4 9 0.310 4.0 Ox 0 VIFx 26.3 135.0 st2 Supply Trunk Detail Table Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (drn) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 737 724 0.284 938 12.0 0 x 0 VinlFlx st1 st1 PeakAVF 1101 1122 0.284 1050 14.0 0 x . 0 VinIFIX .� * wrightsoft® 2020Jan-081624:13 iM a«rtwve.n.w.n.ue.,com,e, Mglt-Sute@)Uriversal20l9l9.O.O7RSU08101 '01 Page 1 slWdgttoftFNACIWYNNE-THESTERLING-IMPACT.np CaIc=MJ8 FrontDoorfaces: N Return Branch Detail Table Name . Grille Size (in) Htg (cfm) . Clg (cfm) TEL (ft) Design FR Veloc (fpm). Diam (in)' H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb1 Ox0 1160 .1160 0 0 .0 0 Ox . 0 MFx -�- wrights—W 2020-Jarr081624:13 RightSute® Uriversal 201919.0.07 RSU08101 Page 2 ...s\wdgWi oftWAQWYNNE-7HESTERLING-IMPACT.rLp Calc=MJ8 FrordDoorfaces: N