HomeMy WebLinkAboutTrussA=LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read given special attention by all persons installing trusses. SPAGING NOTE ALL TRUSSES ARE TO BE SET AT 2'-0ON CENTER EXCEPT AS NOTED DON'T LIFT TRUSSES WITH SPANS LONGER THAN 30' BY THE PEAK. MULTIPLE PLY TRUSSES MUST BE -ASTENED TOGETHER PER ENGINEERIN BEFORE SETTING. REFER TO ENGINEERING DRAWING TO DETERMINE A IF MULTIPLE PLY. A 30' Spanlor less Aj 30' to 60' Span 60 degrees Spreader Bar or less T/ 2 log Line P n oPP REFER TO BCSI Truss must be Set this way if crone used. Truss s an example, your truss may not match. Insist crone operatorsets truss this way. 1.9—Approx 2/3 to Line 1/2 of Span REFER TO BCSI iss must be set this way if crone used. This is an example, truss may not match. Insist crone operator sets truss this way. All load bearing walls, headers, beams & lintels must be in place at indicated height before trusses A are installed. A AIIll" HAfV[7:3PI—E=F2 IVIII TE UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS. CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR. Carrying Girder For Truss to Truss Connections see hanger/connectorTNailsbe as shown. Guide tabs oi schedule in engineeringe nails. package. Carried Truss F� AR"a'14eK5 u+E ElE sT.De a. EN6INFERNGWNC. FRGNP a 2� J -n8o 24' o.c. TNRu I. I CORNER UCKa 1 t•.t •L 01 24, CORNER DETAIL OVERHANGS NOT SHOWN FOR CLARITY i PLATES B CHAMBERS I INDICATES LOAD BEARING REQUIRED BY TRUSSES j SUPPLIED BY BUILDER AT A HEIGHT OF 8'-1" ABOVE FINISHED FLOOR I � i 12 4.00 aim 6,-1 « ri I I I = 1 heel 15/ 6" 3 PLUMB CUT END 2 x 4 Top Chord BEARING HEIGHT 8'-l" ` TYPICAL END DETAIL I r-! ® d --- - ----- 35' -- — - - --- - 14' _ _21, -- 2,111166" m m m m -) 11 m m 7 O] 0- W -) W 'J aD � ro 0 C 7 N 7 ' <V J2 fV J2 [O J4.. J6 JRiLt GRC A6 A4 I A3 A2 I Al I I Al `I Al c0 Al 13'-71" 2 /121 IN . I Al I I Al -cNDI At Al I �.: .. Al a.: O A A S A of Wto pO F- N U_ A U ?� :5 Q Q A W-0a 3WU aZ A FrUO W m Q A z F Z_ O A M A T SETBACK BOSTON HIP TRUSS BH7 GRB r` .00 J3'h 1.0 g J1710B 'oll N 77 B o GRA rn - - - - - - - - - - - - - - o JC in Jc o - N - - fN (V I --------------- - - - - -- - - - N -- -- - - �e 4 4 15' 10" 5'-4" 2' 2^ 9' g" 2' 2" - - 35 GA E LEFT c1 c, ENGTH 21 14' _..---- ----- 2' '16" 2-1 N g 0 cc 0 w co aD m 07 07 07 W sa m V N 'm N J2 N J2 J4 ao J4 0 Js J6 GRC s00 A6 A4 I I A3 I I A2 Al I 7 - 71_ I Al 00 Al N 121 IN 13'-72" Al All Al All I Al o� Al A - A i W O�i A u H — UL On U�7-7 j A W III A �WU - `l Z �m0 A r) W - Z3Z A O ioN A CN T SETBACK BOSTON HIP TRJSS BH7 > F, GRB P B J3 s B J1 >110 11in, 110 ljRn B GRA I I o I ��� �✓e i i rn I JC JC _�----1---------------- N I I. CV N IV It ✓e - - - - - - - I - - -- - - - - - - - - - I N Pro 0 )V-84" « REV 2'.2" 9,-6« 2'_ 54-4« 15'-10" CODE 35' GARAGE RIGHT FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT is SIGNED & RETURNED The legal desolation of the property where the trusses will be Installed Is: t: TNssee will bs made In strict accordance with this truss placement diagram layout, which b the sole aumorfi for deternlning.successful fabrication of the trusses, 2.AII dimensions h this layout have been verified by the undersigned .3. Unlas'a wdaen notce le provided by certified mall to Chambers Truss within ten (10) days 01 delivery the undersigned agrees that no backchargas will be egowed,.ln the event such written notice la fumished Chambers Truss shall have three (3) busjness days fn wnlch it una . The undersigned aUm. It iIsummery cheat by'rPI.dallvery.IChambersJTruseob thaa the soluhyeebrmno the cult I Ity of theJobm th job site lsiteis The buyer is rPortion of the Jesponsible ob site for for additlona delWpnses I penalble arefof Trusa has tor del verepusa Job ska le not prepared for dellvot prepared for delof truasas, 0uyar Ia responsible to Chambers TNae for towidue to eke condltlona.8. Price ee shown Iq paragraph 7 below Is subet tchange If any chan0ea ere made hi his layout A $50 per hour fee for revisions may be charged n Chambers Tnges. . menne Is a PURCHASE ORDER to Chambers, Truss of the sum spread to, or If not agreement a reasodabla price, Invoice will be made on delivery and paid wlthln farms of net On dellvary. Invoice may. be made et scheduled date bf dellvary k buyer cannot accept delivery of fabdceled trusses. The undersigned agrees to pay Chambera.Truss reasonable shomay's fee for colledbna In event of payment not timely made. f-12 °h per month serrjce cheige will be added for all soma not paid-wlthln ...... 8. Signature or Inldals anywhere on this sheet constitutes agreement to all terns herein. B+ In conalderatlon of Chambers Truss extending credit for this materiel the undemlgned uneondlUonally guarantees payment when due of any and all Indpbtedness owed to Chambers Truax by.any entlty recalWna material and the undersigned agrees to pay such Indebtedness InUu•Ing ettpmeys fees, If. default in payment for material be made by the recipient �. - 10. In the event of concern or payments refarad to hemin, th partiesiegreesthat the co a venlua for aryl such aUlon will ba Saint Lucie County, Florida. 11. Design respons flities are per"Nedonal Standard And Rdr4mmsnded ouldellnes On Rasponalblllbes For Constructon Using Metal Plate Connected Wood Trusses ANSI/TPIM?CA4-2002" DATED - SIGNED FOR TrTLE,_�_ nsrywvawrrearmayoeregt Weer"BCSI1-U'topro'mr4iry'ury&damage.. Multiple ply trusses must be fastened together per engineering before they are set failure to do so can result In roof collapse, Temporary and permanent bracing are required and can save life and property and Is the responalblllty of the truss erector. Study the contents of the Information packet Included on delivery before setting trusses, Tnrsaes must beaetand braced per design to prevent: 4ury8, damage. Trusses must be set plumb and square Do not set bunks or stack of plywood roofing material or any other co'ficentrated loads on trusses this can cause collapse. DO NOT SET TRUSSES USING THIS LAYOUT ` USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES I CHAMBERS TRUSS INC 3106 oleander Avenue Fort Plante; Florida 34932-6423 800-551-5932 j IPierce 77,2 A�¢.�?�t}1'9crs or Arc Ter .5 �77ry1-465-8711 Vero Beach 772-569-201; drawing �a� rs 19 I "double cheek•• T a Of, the;contracEor... The contractor shall remjin responsible for cheOking field measurements and other construction criteria. ArchitecT's approval covers geriera� Proof shapez. review of truss strapping, and loading; on structure from pre it y and upffft ads and their rasp c 'vo focatio ��J ^ Approved By r� Date: Braden &: Braden A.I P.A. 92.0/93.2 MITEK 4.2 DESIGN CRITERIA County SAINT, LUCIE Building Department ST LUCIE COUNTY Wind Design Criteria ASCE 7-2010 ;� ` Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10 s Roofing Material Metal Roof a 0 Loadingin PSF Roof R.D.L. ' I ° Top Chord Live 20 o c Top Chord Dead 7 4.2 �+ Bottom Chord Live 10 Non -Concurrent w d Bottom Chord Dead 10 3 a TOTAL Load 37 7.2 Duration Factor 1.25 Wind Speed 165mph Top Chord C.B. Sheeting by builder. Bottom Chord C.B. Sheeting by builder. Highest Mean Height 12'-0" Building Type ENCLOSED Building Category II:Non Restrictive Exposure Category _ C Barrier Island No Conforms to FBC 2017 R.D.L.=Restrainin Dead Load C.B.=Continuous Bracing Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Chambers Truss Inc. Drawing Name: M11324 L.L Scale: 1 /4 1' W 83 total trusses, 27 different trusses. MI 4: SAE ACAD: SAE Reviewed By Date:07/19/12 Revised 03/21/18 E+�R Revised: 3/05/2020 LIAMMNE BUILDING CORP. O CRIPTION: ROYALE PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE 27 TRUS4E3 DRAWINGS ARE ATTACHED TO LAYOUT M 11324 -7& S I /3?-73 (arz-.0I,. - 1 0 • MiTek � RE: ml1324 THE ROYALE Site Information: Customer: WYNNE BUILDING CORPORATION Project Name: ml 1324 Lot/Block: Model: ROYALE Address: UNKNOWN City: ST LUCIE Subdivision: State: FL MiTek USA, Inc. 6904 Parke East Blvd. Tampa, FL 33610-4115 General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 27 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date No. Seal# Truss Name Date 1 T19781776 A 7/7/2020 21 T19781796 JC 7/7/2020 2 T19781777 Al 7/7/2020 22 T19781797 KJ5 7/7/2020 3 T19781778 A2 7/7/2020 23 T19781798 KJ8 7/7/2020 4 T19781779 A3 7/7/2020 24 T19781799 KJA 7/7/2020 5 T19781780 A4 7/7/2020 25 T19781800 KJB . 7/7/2020 6 T19781781 A6 7/7/2020 26 A T19781801 MV2 7/7/2020 7 T19781782 B 7/7/2020 27 T19781802 MV4 7/7/2020 8 T19781783 BH7 7/7/2020 9 10 T19781784 T19781785 GRA GRB 7/7/2020 7/7/2020 FILE COPY 11 T19781786 GRC 7/7/2020 12 T19781787 J1 7/7/2020 13 T19781788 J2 7/7/2020 14 T19781789 J3 7/7/2020 15 T19781790 J4 7/7/2020 16 T19781791 J5 7/7/2020 17 T19781792 J6 7/7/2020 18 T19781793 J8 7/7/2020 19 T19781794 JA 7/7/2020 20 T19781795 JB 7/7/2020 This item has been electronically signed and sealed by ORegan, Philip using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision ,,����� based on the parameters provided by Chambers Truss. ��� �p J • Truss Design Engineer's Name: ORegan, Philip �Q��� �(, My license renewal date for the state of Florida is February 28, 2021. Florida COA: 6634 No 58126 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 3 ,STATE OF 141'iONA%' Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 July 07, 2020 1 of 1 ORegan, Philip A Job Truss Truss Type Ply THE ROYALE T19781776 M11324 A COMMON �Qty 10 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:17 2020 Page 1 ID:_kriGCA6bx7j2Sy1 HDXFw7ye3KX-bdFkwKP1 W Vd5kvh4gXmgUQgkzjKtK4bfmPcjgXzxGq �. �1 0 0 84-0 12-11-0 17 6-0 22-1 0 IUD 35.0-0 a6-0-q -0-0 8 4 0 4-7-0 4-7-0 47-0 47 D 8-4-0 1-0-0' �1 0 Scale = 1:59.3 4.00 12 45 = 6 17 '" 15 "' `" 14 '" 12 4x5 —_ 2x3 II 5x6 WB = 3x8 = 2x3 II 4x5 = 3x8 = 5x6 WB = li a-0 12-11-0 22-1-0 26-8-0 4-7-0 9-2-0 4-7-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Ud TOLL 20.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) 0.33 14-15 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.68 Vert(CT) -0.64 14-15 >652 240 BCLL 0.0 Rep Stress Incr YES WB 0.63 Horz(CT) 0.13 10 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1399/0-8-0.10=1399/0-8-0 Max Horz 2=-223(LC 8) Max Uplift 2=-775(LC 10), 10=-775(LC 10) PLATES GRIP MT20 244/190 Weight: 169 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-1-13 oc pudins. BOT CHORD Rigid ceiling directly applied or 4-10-7 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3404/2226,3-5=-2807/1885,5-6=-2801/1990,6-7=-2801/1990,7-9=-2807/1885, 9-10=-3404/2226 BOT CHORD 2-17=1946/3218, 15-17=-1946/3218, 14-15=-1116/2053, 12-14=-1946/3188, 10-12=-1946/3188 WEBS 6-14=-598/1034, 7-14=-252/246, 9-14=-702/541, 6-15=-598/1035, 5-15=-253/246, 3-15=-701/541 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 12-8-6, Exterior(2) 12-8-6 to 17-6-0, Interior(1) 22-1-0 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) 100.01b AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 775 Ito uplift at joint 2 and 775 lb uplift at joint 10. A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design, Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUiP11 Quality Criteria, DS8.89 and SCSI Building Component Saletylnlormadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldod, MO 20601 This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 MiTek' 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE ROYALE ' T19781777 M11324 Al SPECIAL 9 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:18 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-3gp67gQfHplyL3GGEEHv1 dDr47c73X1 o13LG"jGp r -0 7-8-0 13-7-8 17.6-0 23-11-12 , 26-9-10 , 35-M �1 to 7-8-0 5-11-8 3-10-8 6-5-12 2-9-14 8-2.6 0-0 Scale=1:60.3 �1 5x8 MT18HS = 4.00 12 14 13 3x5 = 2x3 II 5x12 2.00 = 3x12 zz 12 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017frP12014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except' 6-12: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1349/0-8-0, 10=1349/0-8-0 Max Horz 2=-223(LC 8) Max Uplift 2=-825(LC 10). 10=-825(LC 10) 35-M CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TC 0.89 Vert(LL) 0.80 12 >525 360 MT20 244/190 BC 0.94 Vert(CT)-1.3912-13 >302 240 MT18HS 244/190 WB 0.62 Horz(CT) 0.37 10 n/a n/a Matrix -MS Weight: 159 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 6-12 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3309/2433, 3-5=-2581/2012, 5-6=-2548/2113, 6-7=-5337/4002, 7-9=-5302/3868, 9-10=-5702/4143 BOT CHORD 2-14=-2151/3113, 13-14=-2151/3113, 12-13=-145012202, 10-12=-3809/5431 WEBS 3-14=0/265, 3-13=-813/590, 5-13=-269/317, 6-13=-317/567, 6-12=-2362/3388, 7-12=298/368, 9-12=-405/352 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=5011; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 12-8-6, Exterior(2) 12-8-6 to 17-6-0, Interior(1) 22-3-10 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Bearing atjoint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 10. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58128 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd, Tampa FL 33610 Date: March 24,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not �Lee�yj a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall -•Y� building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P11 Quality Criteria, DSB-B9 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply THE ROYALE ' T19781778 M11324 A2 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:19 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-XONULORH26uozDrSoyo8Zd3jXxjoyGyEj5gvQzXjGo �1-0-0 8-0-1 13-7-8 16-0-0 19-0-0 23-11-12 26 9-9 35-0-0 $6-0-q r O 84-1 5-7-7 2-0 8 3-M 4-11-12 2-9-13 8-2-7 1-0-0' 3x5 = 15 2x3 11 4.00 12 5x6 = Sx6 = 4x4 = 2.00 12 3x12 Scale=1:62.3 �l4 IT a 8-0-1 13-7-8 19-0-0 23-11-12 35-0-0 8-0-1 5-7-7 5-4-8 4-11-12 11-0-4 Plate Offsets (X,Y)— [2:0-1-2,Edge], [4:0-2-12,0-3-0], [4:0-0-0,0-1-12], [8:0-3-0,Edae], [8:0-0-0,0-1-12], [9:0-3-2,0-0-0], [10:0-1-15,Edge] LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.70 Vert(LL) 0.75 12 >559 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -1.02 12-21 >412 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.75 Horz(CT) 0.37 10 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 160 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-4-8 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 7-13 REACTIONS. (lb/size) 2=1349/0-8-0, 10=134910-8-0 Max Horz 2=-205(LC 8) Max Uplift 2=-825(LC 10), 10=-825(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3315/2113, 3-5=-2515/1641, 5-6=-2524/1699, 6-7=-2672/1734, 7-9=-5246/3199, 9-10=-5687/3567 BOT CHORD 2-15=-1849/3111, 14-15=-1849/3111, 13-14=-1217/2314, 12-13=-2804/5025, 10-12=-3257/5414 WEBS 3-15=0/300,3-14=-954/692, 5-13=-206/561,6-13=-357/632,7-13=-2796/1678, 7-12=-1082/1957, 9-12=-479/463 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Exterior(2) 31-2-6 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. This item has been 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. electronically signed and 7) Bearing at joint(s) 10 considers parallel to grain value using ANSIIrPI 1 angle to grain formula. Building designer should verify sealed by ORegan, Philip, PE capacity of bearing surface. using a Digital Signature. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at Printed copies of this joint 10. document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd, Tampa FL 33610 Data: March 24,2020 . ......... .... ... ....... ............ . . ®WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII 7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MITek9 connectorsThis design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing • Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MOW IYIOW fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSd7P11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply THE ROYALE T19781779 M11324 A3 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:20 2020 Page 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-7CxsYMSvpQOfbNQfLfJN621EjxHyXPZ5SNgNRs7XjGn 8-0-1 14-0-0 21-0-0 23-11-12 , 26-9-10 35-0-0 36-0-Q -0-0 8-0-1 5-11-15 7-0-0 2.11-12 2-9-14 8-2-6 -0-0 Ann 3x5 = 5x6 = 13 2x3 11 5x6 = 2.00 12 4x6 = 'WA 3x12 Scale=1:61.3 8-0-1 13-7-8 21-0-0 23-11-12 35-0.0 8-0-1 5-7-7 7-4-8 2-11-12 11-0-4 Plate Offsets (X Y)— [2:0-1-2,Edge], [8:0-1-15,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.69 Vert(LL) 0.72 10 >582 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -0.98 10-19 >427 240 MT16HS 2441190 BCLL 0.0 Rep Stress Incr YES WB 0.74 Horz(CT) 0.35 8 n/a n/a BCDL 10.0 Code FBC20171TP12014 Matrix -MS Weight: 158lb FT=0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-5-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1349/0-8-0, 8=1349/0-8-0 Max Horz 2=-181(LC 8) Max Uplift 2=-825(LC 10), 8=-825(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3286/2122, 3-4=-2556/1711, 4-5=-3161/2095, 5-6=-3304/2150, 6-7=-5214/3232, 7-8=5695/3643 BOT CHORD 2-13=1853/3079, 12-13=-1853/3079, 11-12=-133812410, 10-11=-2826/4982, 8-10=3331/5422 WEBS 3-13=0/293, 3-12=-854/595, 4-11=-480/959, 5-11=-360/724, 6-11=2280/1355, 6-1 0=1 118/1934, 7-10=-530/515 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Extedor(2) 31-2-6 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise Indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing atjoint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 8. ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stabllity and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSU7P11 Quality Criteria, DSO-89 and BCSI Building Component SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 MiTek' 6904 Parke East Blvd. Tampa, FL 36610 Jab Truss Truss Type Ply THE ROYALE ' T19781780 MM1324 A4 SPECIAL �Qty 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:22 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-xb2cz2T9L1 GNggalT4MrBTNaQkzc?IfOwhJU WIzXjGI i -1-0-0 6-5-8 12-0-0 17-8-4 23-0-0 23r11-12 26-9-9 35-0-0 -0-0 6-5-8 5.6-8 5-8-4 5-3-12 0111-1 2-9-13 8-2-7 -0-0 Scale = 1:61.3 4.00 12 3x6 = LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 5x6 = 3x4 = 14 13 3x4 3x4 = SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stresslncr YES Code FBC2017/TP12014 REACTIONS. (lb/size) 2=1349/0-8-0, 9=1349/0-8-0 Max Horz 2=157(LC 9) Max Uplift 2=-825(LC 10), 9=-825(LC 10) 5x6 = 2.00 12 5x8 =2x3 II 6 7 35.0-0 3x12 zz CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TC 0.67 Vert(LL) 0.7311-12 >572 360 MT20 244/190 BC 0.96 Vert(CT)-0.9811-20 >429 240 MT18HS 244/190 WB 0.77 Horz(CT) 0.36 9 n/a n/a Matrix -MS Weight: 160 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-5-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3367/2256, 34=3093/2069, 4-5=-2645/1853, 5-6=-3425/2347, 6-7=-5165/3301, 7-8=-5219/3301,8-9=-5704/3714 BOT CHORD 2-14=-2000/3170,13-14=-1488/2537,12-13=-2065/3480,11-12=-2440/4196, 9-11=3399/5431 WEBS 3-14=429/415, 4-14=323/584, 4-13=-142/386, 5-13=-1125/697, 5-12=-141/467, 6-12=861/437, 6-11 =1 145/2016, 8-11=-542/518 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Exterior(2) 31-2-6 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 9. ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, OSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 MiTek' 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE ROYALE T19781781 M11324 A6 HIP 1 1 Job Reference (optional) L.namoers truss, Inc., ron rlerce, rL O. 1Ju 5 IVIdr 1 1 LU 10 1VII I ex I11UU U lUb, II IU. I UV IVIGI LY IL.U9.40 4- rOUC I ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-Pnc?AOUo6LOESg9E1 nt4khwkW8Mmktl Y9L312BzXjGk n1-0-0 6-7-15 10-0-0 13.8-0 21-4-0 25-0-0 I 28-0-1 35-M 0-0 6 7-15 3-0-1 3.8-0 7-8-0 3-8-0 3 4-1 6-7-15 Scale = 1:60.3 n1 0 4.00 12 5x8 = 2x3 II 2x3 II 5x8 = 4 23 24 5 25 26 6 27 28 7 16 15 14 13 t2 11 4x5 — 3x4 = 4x6 = 3x4 = 3x4 = 4x6 = 3x4 = 4x5 35-0-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017lrP12014 CSI. TC 0.71 BC 0.71 WB 0.31 Matrix -MS DEFL. in (]cc) I/deft L/d Vert(LL) 0.60 11-13 >424 360 Vert(CT) -0.78 13 >328 240 Horz(CT) 0.11 9 n/a n/a PLATES GRIP MT20 244/190 Weight: 153 Ib FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-0 cc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-6-3 cc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1118/0-8-0, 14=379/0-8-0, 9=1201/0-8-0 Max Horz 2=-133(LC 8) Max Uplift 2=-692(LC 10), 14=-219(LC 10), 9=-739(LC 10) Max Grav 2=1118(LC 1), 14=454(LC 19), 9=1206(LC 20) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2600/2341, 3-4=-2215/1960, 4-5=-2527/2290, 5-6=-2527/2290, 6-7=-2527/2290, 7-8=2531/2224, 8-9=-2880/2572 BOT CHORD 2-16=2074/2444, 14-16=-1569/2065, 13-14=-1968/2527, 11-13=-1833/2382, 9-11=-2290/2707 WEBS 3-16=495/599, 4-16=-206/347, 4-14=-541/820, 5-14=-526/591, 6-13=-234/311, 7-13=-182/282, 7-11=-355/492, 8-11=-444/551 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 16-9-7, Interior(1) 16-9-7 to 18-2-9, Exterior(2)18-2-9 to 25-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 692 lb uplift at joint 2, 219 lb uplift at joint 14 and 739 lb uplift at joint 9. ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLITP11 Quality Criteria, DSB-89 and BCS/ Building Component Safety Informadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cent 6634 6904 Parke East Blvd. Tampa FL 33610 Data: March 24,2020 MiTek' 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE ROYALE ' T19781782 M11324 B COMMON 3 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 3x4 = 6.13U S Mar 11 LU16 Mel( eK Inaustnes, Inc. I ue Mar L4 1L:b4:24 -LULU rage 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-uzANOjVQtfW53JQaVOJGuT?gYo2TNIhN?oaadzXjGj 6-11-0 13.10-0 , 4x6 = 3 24 11 Scale: 1/2'=1' 3x4 = IA LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/TPI2014 CSI. TC 0.37 BC 0.33 WB 0.12 Matrix -MS DEFL. in Vert(LL) 0.10 Vert(CT) -0.13 Horz(CT) 0.01 (loc) I/deft L/d 5-8 >999 360 5-8 >999 240 4 n/a n/a PLATES GRIP MT20 244/190 Weight: 47 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 7-7-1 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=510/0-8-0, 2=568/0-8-0 Max Horz 2=93(LC 9) Max Uplift 4=-292(LC 10), 2=-377(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-967/954, 3-4=-966/952 BOT CHORD 2-5=785/883, 4-5=-785/883 WEBS 3-5=-84/315 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tail by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 292 lb uplift at joint 4 and 377 lb uplift at joint 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.56126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date; March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not Iva a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Addtional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety In available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply THE ROYALE ' T19781783 M11324 BH7 BOSTON HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:64:25 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-MAkib3W2dyeyh8lc8CvYp6?4vy5bCkwgcfY864zXjGi 15-64) 21-64) 9-0-0 11-6-0 13-6-0 14-041 17.6-0 19"o 21-0-0 23-6-0 25-6-0 2S-0-0 35-0-0 �6-0-0 2$-0 2-0-0 2-0-0 0'-6.01-6-0 2-0-0 2- 1'-6-00=6.0 2-0-0 2-0-0 2.6-0 7-0-0 -0-0 Scale = 1:62.6 3x5 = LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 4.00 12 5x6 = 12 14 16 35 — 33 32 -. 30 SPACING- 2-M Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC20171TP12014 REACTIONS. (lb/size) 2=1349/0-8-0, 28=1349/0-8-0 Max Horz 2=-223(LC 8) Max Uplift 2=-825(LC 10), 28=-825(LC 10) 46 = 3x8 = 3x4 = 4x6 = 3x6 = CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TC 0.72 Vert(LL) 0.51 32-33 >826 360 MT20 244/190 BC 0.56 Vert(CT) -0.67 32-33 >628 240 WB 0.48 Horz(CT) 0.14 28 n/a n/a Matrix -MS Weight: 208 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-8-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-6-1 oc bracing. JOINTS 1 Brace at Jt(s): 11, 18, 15, 7, 23 TOP CHORD MUST BE BRACED BY END JACKS, ROOF DIAPHRAGM, OR PROPERLY CONNECTED PURLINS AS SPECIFIED. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=3392/2640, 3-4=1213/956, 4-8=-1157/946, 8-9=-1145/979, 9-12=-112211028, 12-14=-1125/1090,14-16=-1124/1089,16-19=-1121/1028,19-22=-1145/979, 22-26=-1157/946, 26-27=-1214/956, 27-28=-3393/2641, 3-5=-2373/2046, 5-7=-2376/2050, 7-10=-2376/2050, 10-11=-2376/2050, 11-13=-2376/2050, 13-15=-2376/2050, 15-17=-2376/2050, 17-18=-2376/2050, 18-20=-2368/2046, 20-23=-2368/2046, 23-25=-2368/2046, 25-27=-2364/2041 BOT CHORD 2-35=2358/3190, 33-35=-2360/3166, 32-33=-2652/3448, 30-32=-2361/3167, 28-30=-2358/3191 WEBS 3-35=0/284, 27-30=0/285, 3-33=-317/378, 18-33=-466/474, 27-32=-312/353, 14-15=-405/437 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2)-1-0-0 to 3-9-10, Interior(1) 3-9-10 to 10-8-9, Exterior(2)10-8-9 to 17-6-0, Interior(1) 24-3-7 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 Ib uplift at joint 2 and 825 lb uplift at joint 28. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 511912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing • Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, sea ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 MiTek' 6904 Parke East Blvd, Tampa, FL 36610 Job Truss Truss Type city Ply THE ROYALE - T19781784 M11324 GRA SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MITek Industries, Inc. Tue Mar 24 12:54:27 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-IYsVOIX19augwRS?GdxOuX5ZNrvglw73zl FByzXjGg 1-0-0 4-1-8 5-7-3 8-2-13 9-8-8 13-10-0 14-10-0 1-0-0 4-1.8 1-5 11 2-7-9 1-5-11 4-1-8 1 0 0 l�T7ME 3x4 = 2.37 12 4x4 = 4x4 = 4x10 4x10 19 4 20 21 5 22 6 zz 2x3 II 3x4 = 3x4 = 2x3 II 3x4 = Scale=1:26.6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) 0.08 11 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.32 Vert(CT) -0.10 10 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.06 Horz(CT) 0.03 7 file n/a BCDL 10.0 Code FBC2017lrP12014 Matrix -MS Weight: 58 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-4-7 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 7-0-4 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=770/0-8-0, 7=770/0-8-0 Max Horz 2=-65(LC 6) Max Uplift 2=-523(LC 8), 7=523(LC 8) Max Grav 2=787(LC 17), 7=787(LC 18) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1798/1192, 3-4=1761/1197, 4-5=1724/1169, 5-6=1761/1190, 6-7=-1798/1137 BOT CHORD 2-12=1083/1685, 11-12=-1082/1692, 10-11=-1112/1724, 9-10=-1024/1692, 7-9=1028/1685 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 523 lb uplift at joint 2 and 523 lb uplift at joint 7. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 63 lb down and 114 lb up at 4-1-8, 85 lb down and 124 lb up at 5-0-0, 113 lb down and 146 lb up at 5-7-3, 60 lb down and 129 lb up at 5-11-0, 60 lb down and 129 lb up at 7-11-0, 113 lb down and 146 lb up at 8-2-13, and 85 lb down and 124 lb up at 8-10-0, and 63 lb down and 139 lb up at 9-8-8 on top chord, and 6 lb down and 7 lb up at 4-1-8, 18 lb down and 15 lb up at 5-0-0, 33 lb down at 5-7-3, 39lb down at 5-11-0 , 39 lb down at 7-11-0, 33 lb down at 8-2-13, and 18 lb down and 15 lb up at 8-10-0, and 6 lb down and 7 lb up at 9-8-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 34=-54, 4-5=54, 5-6=54, 6-8=-54, 13-16=-20 Concentrated Loads (lb) Vert: 3=7(B) 4=-64(B) 5=-64(B) 6=7(B) 12=-6(B) 11=-35(B) 10=-35(B) 9=-6(B) 19=-28(B) 20=-60(B) 21=-60(B) 22=-28(B) 23=-18(B) 24=-18(B) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd, Tampa FL 33610 Date: March 24,2020 ® WARNING - verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS97P11 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Intormation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Ply THE ROYALE ' T19781785 M11324 GRB SPECIAL �Qty 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:28 2020 Page 1 ID:_k8GCA6bx7j2SylHDXFw7ye3KX-mIQuESYwwtOXYblBpLSFRkdg49ACP4oHldmojOzXjGf 1-0 5 0-0 10-3-0 15-6.0 21-6-0 26-2 O 28-1-0 35-0-0 6-0 -0-0 5-0-0 5 3.0 5-3 0 6-M 4 8 0 1-11-0 6-11-0 0-0 2x3 II - 4.00 12 4x8 = 3z4 = 3x6 = 3 25 26 4 27 28 29 5 630 31 32 Fel �u�Jt �j N1 2 jj6 18 36 37 17 38 16 39 42 2x3 II 5x15 =4041 3x4 = 3x4 = 3x6 = Scale=1:62.4 4x4 = 2x3 11 4x4 = 9 733 34 35 8 N 10 11 0 I� O 14 4313 12 3x4 =3x6 = 3x4 = 3x4 = 5 0-0 3-0 10-3-0 15 6-0 21.6.0 28-1-0 35-0-0 5-0-0 5 5-3.0 6-0-0 6-7-0 6 11-0 Plate Offsets (X,Y)— [3:0-5-4,0-2-0) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udetl Ud TCLL 20.0 Plate Grip DOL 1.25 TIC 0.41 Vert(LL) 0.11 17-18 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.14 17-18 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.53 Horz(CT) 0.03 10 n/a n/a BCDL 10.0 Code FBC2017lrP12014 Matrix -MS PLATES GRIP MT20 244/190 Weight: 146 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-4-6 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 4-15 REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2=96(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 2=536(LC 8), 15=-846(LC 8), 14=-555(LC 8), 10=-014(LC 8) Max Grav All reactions 250 lb or less at joints) except 2=787(LC 17), 15=1322(LC 1), 14=927(LC 1), 10=506(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=11773/1106, 3-4=-1406/944, 4-6=-304/595, 6-7=-304/595, 7-8=-304/595, 8-9=702/344, 9-10=-719/323 BOT CHORD 2-18=-962/1659, 17-18=-958/1675, 15-17=-843/1406, 14-15=-595/429, 12-14=-158/622, 10-12=-196/636 WEBS 3-18=0/331, 3-17=-297/158, 4-17=0/362, 4-15=2076/1313, 6-15=505/480, 7-14=-431/408, 8-14=-1063/625, 8-12=115/265 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 536 lb uplift at joint 2, 846 Ito uplift at joint 15, 555 lb uplift atjoint 14 and 314 lb uplift atjoint 10. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 257 lb down and 341 lb up at 5-0-0. 100 lb down and 129 lb up at 7-0-12, 100 lb down and 129 lb up at 9-0-12, 100 lb down and 129 lb up at 11-0-12. 100 lb down and 129 lb up at 13-0-12, 100 lb down and 129 lb up at 15-0-12, 100 lb down and 129 lb up at 17-0-12, and 100 lb down and 129 lb up at 19-0-12, and 100 lb down and 129 lb up at 21-1-4 on top chord, and 83 lb down at 5-0-0, 39 lb down at 7-G-12, 39 lb down at 9-0-12. 39 lb down at 11-0-12, 39 lb down at 13-0-12, 39 lb down at 15-0-12, 39 lb down at 17-0-12, and 39 lb down at 19-0-12, and 39 lb down at 21-1.4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard :ontinued on page 2 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5i19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSBTPIf Quality Criteria, DSB-89 and BCS/ Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 Iva MiTek' 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Ply THE ROYALE T19781785 M11324 GRB �Qty SPECIAL 1 1 Job Reference (optional) Chambers Iruss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:28 2020 Page 2 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-mlQuE5YwwtOXYbl BpLSFRkdg49ACP4oHldmojOzXjGf LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-8=-54, 8-9=-54, 9-11=-54, 19-22=-20 Concentrated Loads (lb) Vert: 3=-160(F)18=-45(F) 25=-60(F) 26=-60(F) 27=-60(F) 29=-60(F) 30=-60(F) 31=-60(F) 32=-60(F) 33=60(F) 36=-13(F) 37=-13(F)38=-13(F) 39=-13(F) 40=-13(F) 41=13(F) 42=-13(F) 43=-13(F) ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not �• a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall ii��YY■■ building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Oty Ply THE ROYALE T19781786 M11324 GRC HIP 1 1 Job Reference (optional) —•••-•••-"'••' • ••••"'• ••••'•• •'•• • •"��• • e.IJV 5.—I r r GU 10 rVll IUK rr1UU5Lr1e5, rnu. i ue mar L9-IL:04:au LULU rage 1 ID: kftGCA6bx7j2Sy1HDXFw7ye3KX-i7XeenZBSVGFnvBaxlVjW9jxmzm3tvGamxFvoHzXjGd 1-0-0 8-M 13.8-0 17.6.0 21-4-0 27-0-0 35-0-0 6-0 0-0 8-0-0 5-8.0 3 10-0 3-10 0 5-8-0 8-M 0-0 Scale = 1:60.3 5x8 MT18HS = 5x8 MT18HS = 4.00 12 2x3 II 3x8 = 3x6 = 2x3 II 3 23 24 25 4 26 27 285 6 729 30 31 32 8 Jo w 7 ou 0 0 J1 •'•' 1z JS 3x5 = 2x3 11 3x6 = 6x10 = 6x10 3x6 = 2x3 11 3x5 = 8-M , 13-M 21-4-0 27-0-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress incr NO Code FBC2017/TPI2014 CSI. TC 0.71 BC 0.67 WB 0.79 Matrix -MS DEFL. in (loc) I/deft Ud Vert(LL) 0.22 11-22 >999 360 Vert(CT) -0.31 13-14 >830 240 Horz(CT) . 0.05 9 n/a n/a PLATES MT20 MT18HS Weight: 157 lb GRIP 244/190 244/190 FT = 0% LUMBER. BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-5-6 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-9-3 oc bracing. WEBS 2x4 SP No.3 *Except* WEBS 1 Row at midpt 3-14. 5-14 4-14,7-13: 2x6 SP No.2 REACTIONS. (lb/size) 2=412/0-8-0, 14=3582/0-8-0, 9=1192/0-8-0 Max Horz 2=-109(LC 6) Max Uplift 2=299(LC 8), 14=-2133(LC 8), 9=764(1_C 8) Max Grav 2=423(LC 17), 14=3582(LC 1), 9=1194(LC 18) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=377/225, 34=-109311954, 4-5=-1093/1954, 5-7=-1943/1220, 7-8=-1943/1220, 8-9=2776/1671 BOT CHORD 2-16=154/317, 14-16=-160/350, 11-13=-1475/2624, 9-11=1464/2591 WEBS 3-16=-200/679, 3-14=-2514/1528, 4-14=-641/586, 5-14=-2674/1707, 5-13=-1124/2080, 7-13=-592/548, 8-13=-760/483, 8-11 =-201/684 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide This item has been will fit between the bottom chord and any other members. electronically Signed and 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 299 lb uplift at joint 2, 2133 lb uplift at sealed by ORegan, Philip, PE joint 14 and 764 lb uplift at joint 9. using a Digital Signature. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 182 lb down and 312 lb up at 8-0-0, 107 lb down 173 lb Printed copies of this P and up at 10-0-12, 107 lb down and 173 lb up at 12-0-12, 107 lb down and 173 lb up at 14-0-12, 107 lb down and 173 lb up at 16-0-12, 107 lb down and 173 lb up at 16-11-4, 107 lb down and 173 lb up at 18-11-4, 107 lb down and 173 document are not considered lb up at 20-11-4, 107 lb down and 173 lb up at 22-11-4, and 107 lb down and 173 lb up at 24-11-4, and 182 lb down and 312 lb up signed and sealed and the at 27-0-0 on top chord, and 411 lb down and 242 lb up at 8-0-0, 79 lb down and 1 lb up at 10-0-12, 79 lb down and 1 lb up at signature must be verified 12-0-12, 79 lb down and 1 lb up at 14-0-12, 79 lb down and 1 lb up at 16-0-12, 79 lb down and 1 lb up at 16-11-4, 79 lb down and on an electronic copies. 1 lb up at 18-11-4, 79 lb down and 1 lb up at 20-11.4, 79 lb down and 1 lb up at 22-11-4, and 79 lb down and 1 lb up at 24-11-4, y P and 411 lb down and 242 lb up at 26-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility Philip J. O'Regan PE No.58126 of others. MiTek USA, Inc. FL Cart 6634 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 6904 Parke East Blvd. Tampa FL 33610 Date: LOAD CASE(S) Standard March 24,2020 Continued on page 2 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MTekO connectors. This design Is based only upon parameters shown, and is for an individual building component, not Nat a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSM11 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE ROYALE T19781786 M11324 GRC HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:30 2020 Page 2 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-i7XeenZBSVGFnvBaxlVjW9jxmzm3tvGamxFvoHzXjGd LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-8=-54, 8-10=-54, 17-20=-20 Concentrated Loads (lb) Vert: 3=-126(B)6=-107(B)8=-126(B)15=-50(B)16=-411(B)11=-411(B)12=-50(B)23=-107(B)25=-107(B)26=-107(B)27=-107(B)28=-107(B)29=107(B) 30=-107(B) 32=-107(B) 33=-50(B) 34=-50(B) 35=-50(B)36=-50(B) 37=-50(B) 38=-50(B) 39=-50(B) ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall m mybuilding design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 1 VliTek♦ is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?PH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Infonnadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf. MD 20601 Tampa, FL 36610 Job Truss Type Qty Ply THE ROYALE �Truss T19781787 M11324 A MONO TRUSS 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:31 2020 Page 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-AK5Os7apDoO5P3mmVTOy3NFEuMGVcYtj_a1SKjzXjGc 1-0-0 3x4 = Scale = 1:6.1 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 5 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.02 Vert(CT) -0.00 5 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 5 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc pudins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=9/Mechanical, 2=118/0-8-0, 4=0/Mechanical Max Harz 2=48(LC 10) Max Uplift 3=-4(LC 7), 2=-140(LC 10) Max Grav 3=11(LC 15), 2=118(LC 1), 4=17(LC 10) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at joint 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Data: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Ply THE ROYALE T19781788 J2 MONO TRUSS ToM11324 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:31 2020 Page 1 ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-AK50s7apDoO5P3mmVTOy3NFEuMFhcYtj a?SKjzXjGc i -1-0-0 2-0-0 1-0-0 2-0-0 Scale = 1:7.8 3x4 = 2-0-0 2-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/deft Ltd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.07 Vert(CT) -0.00 7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MP Weight: 8 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=37/Mechanical, 2=141/0-8-0, 4=23/Mechanical Max Horz 2=67(LC 10) Max Uplift 3=-28(LC 10), 2=-136(LC 10), 4=-3(LC 7) Max Grav 3=42(LC 15), 2=141(LC 1), 4=31(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 136 lb uplift at joint 2 and 3 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. ORegan PE No.58128 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Data: March 24,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall r Welk' r� 8 k° building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Mi 1 is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfrPH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job ss Truss Type City Ply THE ROYALE TJ3u ' T19781789 M11324 MONO TRUSS 2 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:32 2020 Page 1 ID:_kflGCA6bx7j2Syl HDXFw7ye3KX-fWfO3TbR_6Wyl DLy2AXBbaoPemaML?7sDEkOsAzXjGb 1-0-0 3-0-0 1-0.0 3-0-0 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) 0.01 4-7 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.17 Vert(CT) -0.01 4-7 >999 . 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017TrPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=64/Mechanical, 2=173/0-8-0, 4=37/Mechanical Max Horz 2=85(LC 10) Max Uplift 3=-54(LC 10), 2=147(LC 10), 4=-4(LC 10) Max Grav 3=70(LC 15), 2=173(LC 1), 4=50(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:9.4 PLATES GRIP MT20 2441190 Weight: 11 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint 2 and 4 Ito uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 511912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply THE ROYALE • rls7anso M11324 J4 MONO TRUSS 4 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL -1-M 3x4 = 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:64:33 2020 Page 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-7iDnHoc3lQepfMv9cu2Q8oLW4AtR4SNOSuUZOczXjGa 4-0-0 4-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deb Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.02 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017lrP12014 Matrix -MP Weight: 14 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=89/Mechanical, 2=206/0-8-0, 4=50/Mechanical Max Horz 2=104(LC 10) Max Uplift 3=-79(LC 10), 2=-161(LC 10), 4=8(1_C 10) Max Grav 3=97(LC 15), 2=206(LC 1), 4=67(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 3, 161 lb uplift at joint 2 and 8 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J.O'Regan PE No.58128 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIVTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply THE ROYALE T19781791 M11324 J5 MONO TRUSS 11 1 Job Reference (optional) Chambers I cuss, Inc., Fort Pierce, t-L 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:33 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-7iDnHoc3lQepfMv9cu2Q8oLSAApH4SNOSuUZOczXjGa 1-0-0 5-0-0 Scale = 1:12.7 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Ildefl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.70 Vert(LL) 0.06 4-7 >939 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.64 Vert(CT) -0.06 4-7 >964 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a rile BCDL 10.0 Code FBC2017frP12014 Matrix -MP Weight: 17 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=115/Mechanical, 2=243/0-8-0, 4=63/Mechanical Max Horz 2=123(LC 10) Max Uplift 3=-104(LC 10), 2=-177(LC 10), 4=9(LC 10) Max Grav 3=125(LC 15), 2=243(LC 1), 4=87(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tail by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at joint 2 and 9 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Data: March 24,2020 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE. -- Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall q� building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the IYIiTek• fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS117P/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply THE ROYALE T19781792 M11324 J6 MONO TRUSS 4 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:34 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-bvn9UBdhWjmgGWULAbZfg?UWa6ypvd9hYD6x2zXjGZ 1-0-0 6.0-0 1.0.0 6-0-0 3x4 = LOADING (psg SPACING- 2-0-0 CSI. DEFL. in (loc) I/de0 Ud TCLL 20.0 Plate Grip DOL 1.25 TIC 0.34 Vert(LL) 0.11 4-7 >664 360 TCDL 7.0 Lumber DOL 1.25 BC 0.80 Vert(CT) -0.11 4-7 >652 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=142/Mechanical, 2=275/0-8-0, 4=70/Mechanical Max Horz 2=140(LC 10) Max Uplift 3=-129(LC 10), 2=-192(LC 10), 4=-8(LC 10) Max Grav 3=155(LC 15), 2=276(LC 15), 4=100(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:14.3 PLATES GRIP MT20 244/190 Weight: 20 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 129 lb uplift at joint 3, 192 lb uplift at joint 2 and 8 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Data: March 24,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall MiTek* k•• building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the iVl fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11rPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type city Ply THE ROYALE ];MONO T19781793 IA11324 J8 TRUSS 11 1 Job Reference (optional) L;nambers truss, Inc., Fort Pierce, FL 1-0-0 3x4 7.0-0 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:35 2020 Page 1 ID:kFvnsnOwY419ZhO_nM3lc6ylJ9g-35LXiUdJH 1 vXug3XkJ4uDDQp7_XMYMtJvCzgTVzXjGY 8.0-0 Scale=1:17.5 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.61 Vert(LL) -0.14 4-7 >676 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.47 Vert(CT) -0.30 4-7 >310 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Wind(LL) 0.26 4-7 >368 240 Weight: 26 lb FT = 20% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 REACTIONS. (lb/size) 3=188/Mechanical, 2=348/0-8-0, 4=99/Mechanical Max Horz 2=178(LC 12) Max Uplift 3=-174(LC 12), 2=-226(LC 12), 4=-13(LC 12) Max Grav 3=195(LC 17), 2=348(LC 1). 4=141(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Interior(1) 2-7-3 to 7-10-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 3, 226 lb uplift at joint 2 and 13 lb uplift atjoint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33810 Date: March 24,2020 ®WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not ® my a truss system. Before use, the building designer must verify the applicability of design parameters and propedy Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MI'�'®k' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information avallabie from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply THE ROYALE T19781794 M11324 JA MONO TRUSS 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:36 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-XHuvvgex2L1 OWgekHOc7mCiz5eNyVHp7SBsiD7xzxjGX 2-4-3 1-0-0 2-4-3 Scale = 1:8.3 3x4 = LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.09 Vert(CT) -0.00 7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC20171TPI2014 Matrix -MP Weight: 9 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-4-3 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=45/Mechanical, 2=150/0-8-0, 4=28/Mechanical Max Horz 2=73(LC 10) Max Uplift 3=-37(LC 10), 2=139(LC 10), 4=-4(LC 7) Max Grav 3=50(LC 15), 2=150(LC 1), 4=37(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; 13=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0,18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 37 lb uplift at joint 3, 139 lb uplift at joint 2 and 4 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.56126 MiTek USA, Inc. FL Cart 6634 6904 Parka East Blvd. Tampa FL 33610 Data: March 24,2020 ®WARNING -Verify design parameters end READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall p p� building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Ib1 iTe k• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-99 and BCSI Building Component 6904 Parke East Blvd. Safety Intormafion available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job ss Truss Type Qty Ply THE ROYALE TJB T19781795 a111324 MONO TRUSS 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 3x4 = 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:36 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-XHuvvgex2L1 OWgekHOc7mOz10Nm?Hp7S8siD?xzXjGX Scale = 1:12.5 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.38 Vert(LL) 0.10 4-7 >645 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.89 Vert(CT) -0.07 4-7 >898 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC20171TPI2014 Matrix -MP Weight: 19 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-5-11 oc pudins. BOT CHORD 2x4 SIP No.3 BOT CHORD Rigid ceiling directly applied or 5-0-0 oc bracing. REACTIONS. (lb/size) 3=127/Mechanical, 2=269/0-8-0, 4=63/Mechanical Max Horz 2=114(LC 10) Max Uplift 3=-109(LC 10), 2=-206(LC 10), 4=-6(LC 10) Max Grav 3=127(LC 15), 2=269(LC 1), 4=90(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 109 lb uplift at joint 3, 206 lb uplift at joint 2 and 6 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. G'Regan PE No.58126 MiTek USA, Inc. FL Cent 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MirekO connectors. This design Is based only upon parameters shown, and is for an individual building component, not ® a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall p Nat building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MOW k• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Job Truss Truss Type City Ply THE ROYALE ' T19781796 JC MONO TRUSS 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:37 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-?USH6Afape9F7_Dwrk7MIeVGNnJvOGNbNWSmXNzXjGW 1-0-0 1-1-4 1-0-0 1-1-4 Scale = 1:6.2 3x4 = LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Udefi L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 5 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.02 Vert(CT) -0.00 5 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MP Weight: 5 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 1-1-4 oc pudins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=11/Mechanical, 2=119/0-8-0, 4=4/Mechanical Max Horz 2=50(LC 10) Max Uplift 3=-6(LC 7), 2=-138(LC 10) Max Grav 3=14(LC 15), 2=119(LC 1), 4=14(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 6 lb uplift at joint 3 and 138 lb uplift at joint 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not �a a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIMPH Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety lnformatfon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job s Truss Type City Ply THE ROYALE TK'Ju5s T19781797 y111324 MONO TRUSS 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MITek Industries, Inc. Tue Mar 24 12:54:38 2020 Page 1 ID:_kflGCA6bx7j2Sy1 HDXFw7ye3KX-TgOgKWgCayH618o6PRebr2OYBbJljclbABK4pzXjGV -1-5-0 3-11-0 7-0-2 r 1-5-0 3-11-0 3-1-2 2.83 12 3x4 = Scale = 1:15.7 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deb Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.34 Vert(LL) 0.09 4-7 >923 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.26 Vert(CT) -0.15 4-7 >563 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MP Weight: 23 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=194/Mechanical, 2=233/0-11-5, 4=94/Mechanical Max Horz 2=109(LC 8) Max Uplift 3=-174(LC 8), 2=-191(LC 8) Max Grav 3=198(LC 13), 2=233(LC 1), 4=133(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 3 and 191 lb uplift at joint 2. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54 Trapezoidal Loads (plf) Vert: 2=0(F=27, B=27)-to-3=-95(F=-20, B=-20), 5=0(F=10, B=10)-to-4=-35(F=-8, B=-8) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MITek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33810 Date: March 24,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 101II-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component not a truss system. Before use, the building designer must verily the applicability of design parameters and property incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7fPl1 Quality Criteria, DSB-89 and BCSI Bulld/ng Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply THE ROYALS ' T19781798 10111324 KJ8 MONO TRUSS 2 1 Job Reference (optional) chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:39 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-xsa2XsggKGPzNHNlz89gN3bblbyjU50ugqxtcGzXjGU 1-5-0 7-2-7 11-3-0 1-5.0 7-2-7 4-0-9 3x4 = 3x4 = 7-2-7 13-10-5 0-2 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (too) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.21 Vert(LL) 0.08 6-9 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.25 Vert(CT) -0.10 6-9 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.35 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 44 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 9-10-15 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=90/Mechanical, 2=465/0-11-5, 5=409/Mechanical Max Horz 2=178(LC 8) Max Uplift 4=-91(LC 8), 2=332(LC 8), 5=223(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-875/541 BOT CHORD 2-6=535/842, 5-6=-535/842 WEBS 3-6=1/287, 3-5=-923/587 NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf, h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 91 lb uplift at joint 4, 332 lb uplift at joint 2 and 223 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 38 lb down and 61 lb up at 2-11-0, 38 lb down and 61 lb up at 2-11-0, 8 lb down and 106 lb up at 5-8-15, 8 lb down and 106lb up at 5-8-15, and 42 lb down and 145 lb up at 8-6-14, and 42 lb down and 145 lb up at 8-6-14 on top chord, and 31 lb up at 2-11-0, 31 lb up at 2-11-0, 11 lb This item has been down and 31 lb up at 5-8-15, 11 lb down and 31 lb up at 5-8-15, and 31 lb down and 14 lb up at 8-6-14, and 31 lb down and 14 lb up at 8-6-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. electronically Signed and 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Sealed by ORegan, Philip, PE LOAD CASE(S) Standard using a Digital Signature. 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Printed copies of this Uniform Loads (plf) document are not considered Vert: 1-4=-54, 5-7=-20 signed and sealed and the Concentrated Loads (Ib) signature must be verified Vert: 10=80(F=40, B=40) 11=-5(F=-3, B=-3) 12=-83(F=-42, B=-42) 13=14(F=7, B=7) 14=-21(F=-11, B=-11) 15=-50(F=-25, on an electronic copies. B=-25) Y P Philip J. O Regan PE No.58128 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MTekO connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall �a building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUfPH Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply THE ROYALE • T19781799 M11324 KJA MONO TRUSS 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL -1-2-9 3x4 = 8.130 s Mar 112018 MITek Industries, Inc. Tue Mar 24 12:54:39 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-xsa2XsggKGPzNHNlz89gN3bbNbzyUAsuqqxtcGzXjGU Scale = 1:13.6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.21 Vert(LL) 0.04 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.17 Vert(CT) -0.07 4-7 >974 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017(rPI2014 Matrix -MP Weight: 20 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=142/Mechanical, 2=181/0-9-11, 4=69/Mechanical Max Horz 2=97(LC 8) Max Uplift 3=-129(LC 8), 2=-150(LC 8) Max Grav 3=145(LC 13), 2=181(LC 1), 4=104(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; 8=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 129 Ito uplift at joint 3 and 150 lb uplift at joint 2. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-64 Trapezoidal Loads (plf) Vert: 2=0(F=27, 13=27}to-3=-81(F=-14, B=-14), 5=0(F=10, B=10}to-4=-30(F=-5, B=5) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.56126 MITek USA, Inc. FL Cart 6034 6904 Parke East Blvd. Tampa FL 33610 Data: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE. ° Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M!Te k° Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP11 Quality Criteria, DSS-69 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa. FL 36610 Job Truss Truss Type Qty Ply THE ROYALE ' T19781800 M11324 KJB MONO TRUSS 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:40 2020 Page 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-Q28QIChS5ZXq_RyV Wsg3wG7oh?KKDd623UgR8izXjGT 1-2-9 4-11-9 1-2-9 4-11-9 3x4 = 4-11-9 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Lid TCLL 20.0 Plate Grip DOL 1.25 TC 0.11 Vert(LL) -0.02 4-7 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.10 Vert(CT) -0.03 4-7 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 REACTIONS. (lb/size) 3=95/Mechanlcal, 2=148/0-9-11, 4=46/Mechanical Max Horz 2=75(LC 8) Max Uplift 3=-84(LC 8), 2=-136(LC 8) Max Grav 3=95(LC 1), 2=148(LC 1), 4=77(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. 1_=178RilIIN PLATES GRIP MT20 244/190 Weight: 17 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 4-11-9 oc purfins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 84 lb uplift at joint 3 and 136 lb uplift at joint 2. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard. 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54 Trapezoidal Loads (plf) Vert: 2=0(F=27, 13=27}1to-3=-67(F=-7, 13=7), 5=0(F=10, 1]11=10}to4=-25(F=2, 8=2) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-B9 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Type Ply THE ROYALE • T19781801 M11324 JTruss MV2 VALLEY �Qty 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.04 TCDL 7.0 Lumber DOL 1.25 BC 0.02 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017/TPI2014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 1=41/2-0-0, 2=30/2-0-0, 3=11/2-0-0 Max Horz 1=21(LC 10) Max Uplift 1=-20(LC 10), 2=-30(LC 10) Max Grav 1=42(LC 15), 2=32(LC 15), 3=22(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:41 2020 Page 1 ID:_kflGCA6bx7j2Syl HDXFw7ye3KX-uFioyXl4stfhcbXh4ZBITUg_ROhoy4MB18Q_h8zXjGS 2-0-0 4.00 12 3x4 DEFL. in (loc) Udefl Ud PLATES GRIP Vert(LL) n/a n/a 999 MT20 244/190 Vert(CT) n/a n/a 999 Horz(CT) -0.00 2 n/a n/a Scale = 1:6.1 Weight: 5 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 20 lb uplift at joint 1 and 30 lb uplift at joint 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58128 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/192020 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not HT BE a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabdcatlon, storage, delivery, erection and bracing of trusses and truss systems, see ANSITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Ply THE ROYALE • T19781802 M11324 MV4 VALLEY �Qty 1 1 Job Reference (optional) cnamoers I fuss, Inc., r•ort rierce, t•L t" Ju s Its mar i i zu mi I eK inausmes. Inc. i ue mar z4 i z:ov:v I du du rage , ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-uFioyXi4stfhcbXh4ZBITUgvHOfUy4MB18Q_h8zXjGS 4-0-0 4-0-0 Scale = 1:9.4 3 3x4 3x4 II I LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) We n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.17 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix-P Weight: 12 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BOT CHORD REACTIONS. (lb/size) 1=109/4-0-0, 3=109/4-0-0 Max Horz 1=56(LC 10) Max Uplift 1=-54(LC 10), 3=72(LC 10) Max Grav 1=112(LC 15), 3=117(LC 15) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Structural wood sheathing directly applied or 4-0-0 oc puriins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10: Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 1 and 72 lb uplift at joint 3. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.66126 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Data: March 24,2020 A WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component. not a thus system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall r building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M'i'®k* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfrP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Symbols PLATE LOCATION AND ORIENTATION Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0-116rr For 4 x 2 orientation, locate plates 0- yie" from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. O of O 2 U o- O H Numbering System 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 O of O 2 U EL O F— JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS [CC -ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MiTek@ All Rights Reserved Nil MiTek � MiTek Engineering Reference Sheet: Mll-7473 rev. 5/19/2020 ® General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSUTPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or puriins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSVTPI 1 Quality Criteria. 21.The design does not take into account any dynamic or other loads other than those expressly stated. ', JANUARY 20, 2020 TYPICAL HIP/ KING JACK CONNECTION STDTL CORNERSET GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 175 mph, ASCE 7-10, Exp. B, C up to 60' Mean Roof Height and Exposure D up to 30' Mean Roof Height. i Attach End J ck's w/ (4) 16d Toe ails @ TC & (3) 16d Toe ails @ BC Q 2E CD I O CD \ \ Attach King Jack w/ (3) 16d Toe Nails @ TC & BC 1 Attach Corne'Jack's w/ (2) 16d To Nails @ TC & BC (Typical) p .. "•j`j� •r p r Chambers Truss, Inc. PAUL WELCH INC. MECH-ELECT-CIVIL ENG 3105 Oleander Ave. r, 1984 BILTMORE ST.:14 PORT ST. LUCIE FL 34984 Ft. Pierce FI. 34982 - :PAUL.WELCH, P.E. FLR REG NO29M Ph: 772-465-2012 X :a AUGUST 1, 2016 0 00 0 00 LU T-11:1 MiTek USA, Inc. ftT �f j'�I j7 IARUMAINato LATERAL TOE -NAIL DETAIL MII-TOENAIL SP MTek USA, Inc. NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45 DEGREES WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT. (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. THIS DETAIL APPLICABLE TO THE THREE END DETAILS SHOWN BELOW OE -NAIL SINGLE SHEAR VALUES PER NDS 2001 (lb/nail) DIAM. SP DF HF SPF SPF-S .131 88.0 80.6 69.9 68.4 59.7 Fz .135 93.5 85.6 74.2 72.6 63.4 in .162 108.8 99.6 86.4 I 84.5 73.8 6 z Z .128 74.2 67.9 58.9 57.6 50.3 .131 75.9 69.5 60.3 59.0 51.1 tn 148 81.4 74.5 64.6 63.2 52.5 VALUES SHOWN ARE CAPACITY PER TOE -NAIL APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY SIDE VIEW (2x3) . 2 NAILS XNEAR SIDE NEAR SIDE Page 1 of 1 EXAMPLE: SIDE VIEW SIDE VIEW (3) -16d (0.162" X 3.51 NAILS WITH SPF SPECIES BOTTOM CHORD N4 NAILS ILS 3 NA For load duration increase of 1.15: NEAR SIDE NEAR SIDE 3 (nails) X 84.5 (lb/nail) X 1.15 (DOL) = 291.5 lb Maximum Capacity 1 NEAR SIDE NEAR SIDE A E NEAR SIDE NEAR SIDE NEAR SIDE ANGLE MAY ANGLE MAY \VARY FROM VGLE MAY VARY FROM 0° TO 60 ° RYFROM30° TO 60°45.00°° TO 60 ° 45.000 �' 45.00 ° E