HomeMy WebLinkAboutJAAR- SPRUCE REVISION- ENERGY CALC (1)EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 610/29/2020 4:43 PM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
JAAR ENTERPRISES, LLC.JAAR ENTERPRISES LLC- 5809 SPRUCE DR
Street:
City, State, Zip: FORT PIERCE , FL , 34982
5809 SPRUCE DRIVE
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Single-family
1
No
1781
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.65 216.33 ft²
SHGC=0.25
N/A f t ²
N/A f t ²
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 1781.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 1499.00 ft²
b. Frame - Wood, Adjacent R=11.0 248.00 ft²
c. N/A R=f t ²
10. Ceiling Types
a. Roof Deck (Unvented)R=20.0 1781.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 50 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:1.500 ft.
Area Weighted Average SHGC:0.250
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits None
3
(216.3 sqft.)
(1747.0 sqft.)
(1781.0 sqft.)
(1781.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
30.0 SEER:16.00
Efficiency
k B t u / h r Efficiency
27.0 COP:1.00
f t ² R
6 140
EF: 0.980
Glass/Floor Area: 0.121
Total Proposed Modified Loads:
Total Baseline Loads:
62.57
63.20 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
11-3-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
JAAR ENTERPRISES, LLC.
1
JAAR ENTERPRISES LLC- 5
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
1781
3
New (From Plans)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL , 34982
FORT PIERCE ,
St. Lucie
5809 SPRUCE DRIVE
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 1781 19328
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 BEDROOM 2 188 1504 No 0 1 Yes Yes1 Yes
2 CLST 2 20 160 No 0 Yes Yes1 Yes
3 BATH 2 50 400 No 0 Yes Yes1 Yes
4 CLST 3 20 160 No 0 Yes Yes1 Yes
5 BEDROOM 3 169 1352 No 0 1 Yes Yes1 Yes
6 LIVING ROOM 300 4200 No 0 Yes Yes1 Yes
7 FOYER DINING RO 240 3360 No 0 Yes Yes1 Yes
8 NOOK 130 1820 No 0 Yes Yes1 Yes
9 KITCHEN 130 1820 Yes 0 Yes Yes1 No
10 LAUNDRY 70 560 No 0 Yes Yes1 Yes
11 MASTER BEDROO 280 2520 No 0 1 Yes Yes1 Yes
12 M WIC 54 432 No 0 Yes Yes1 No
13 M BATH 109 872 No 0 Yes Yes1 Yes
14 HALL 21 168 No 0 Yes Yes1 No
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 188 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -027 ft BEDROOM 2
2 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 2
3 50 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH 2
4 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 3
10/29/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
5 169 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -026 ft BEDROOM 3
6 300 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -015 ft LIVING ROOM
7 240 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -015 ft FOYER DINING
8 130 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -010 ft NOOK
9 130 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft KITCHEN
10 70 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft LAUNDRY
11 280 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -035 ft MASTER BEDRO
12 54 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M WIC
13 109 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -09 ft M BATH
14 21 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Composition shingles 1992 ft² Medium 0.3 20 26.6______No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 1781 ft² N N0
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented)0 188 ft² 0.1 Wood______BEDROOM 2 Blown
2 Under Attic (Unvented)0 20 ft² 0.1 Wood______CLST 2 Blown
3 Under Attic (Unvented)0 50 ft² 0.1 Wood______BATH 2 Blown
4 Under Attic (Unvented)0 20 ft² 0.1 Wood______CLST 3 Blown
5 Under Attic (Unvented)0 169 ft² 0.1 Wood______BEDROOM 3 Blown
6 Under Attic (Unvented)0 300 ft² 0.1 Wood______LIVING ROOM Blown
7 Under Attic (Unvented)0 240 ft² 0.1 Wood______FOYER DINING Blown
8 Under Attic (Unvented)0 130 ft² 0.1 Wood______NOOK Blown
9 Under Attic (Unvented)0 130 ft² 0.1 Wood______KITCHEN Blown
10 Under Attic (Unvented)0 70 ft² 0.1 Wood______LAUNDRY Blown
11 Under Attic (Unvented)0 280 ft² 0.1 Wood______MASTER BEDRO Blown
12 Under Attic (Unvented)0 54 ft² 0.1 Wood______M WIC Blown
13 Under Attic (Unvented)0 109 ft² 0.1 Wood______M BATH Blown
14 Under Attic (Unvented)0 21 ft² 0.1 Wood______HALL Blown
10/29/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0BEDROOM 2 00014 8N Concrete Block - Int Insul 0.30Exterior112.0 ft² ____
2 4.1 0BEDROOM 2 00013 8W Concrete Block - Int Insul 0.30Exterior104.0 ft² ____
3 4.1 0CLST 2 0002 8N Concrete Block - Int Insul 0.30Exterior16.0 ft² ____
4 4.1 0BATH 2 0005 8N Concrete Block - Int Insul 0.30Exterior40.0 ft² ____
5 4.1 0CLST 3 0002 8N Concrete Block - Int Insul 0.30Exterior16.0 ft² ____
6 4.1 0BEDROOM 3 00013 8E Concrete Block - Int Insul 0.30Exterior104.0 ft² ____
7 4.1 0BEDROOM 3 00013 8N Concrete Block - Int Insul 0.30Exterior104.0 ft² ____
8 4.1 0LIVING ROO 00015 14W Concrete Block - Int Insul 0.30Exterior210.0 ft² ____
9 4.1 0FOYER DINI 00015 14E Concrete Block - Int Insul 0.30Exterior210.0 ft² ____
10 4.1 0NOOK00010 14W Concrete Block - Int Insul 0.30Exterior140.0 ft² ____
11 4.1 0LAUNDRY0007 8E Concrete Block - Int Insul 0.30Exterior56.0 ft² ____
12 4.1 0MASTER BE 00017 9S Concrete Block - Int Insul 0.30Exterior153.0 ft² ____
13 4.1 0MASTER BE 00018 9W Concrete Block - Int Insul 0.30Exterior162.0 ft² ____
14 4.1 0M BATH 0009 8S Concrete Block - Int Insul 0.30Exterior72.0 ft² ____
15 11 0M BATH 021 8E Frame - Wood 0.30.1Garage168.0 ft² ____
16 11 0LAUNDRY010 8S Frame - Wood 0.30.1Garage80.0 ft² ____
#Door Type U-Value AreaStorms
DOORS
Ornt Space Width
Ft In Ft In
Height
1 Wood .2 .1 ft² None______N BEDROOM 2 .1.1
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 W Low-E Single 0.65 0.25 15.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes2 N
2 N Low-E Single 0.65 0.25 6.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes4 N
3 E Low-E Single 0.65 0.25 15.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes6 N
4 W Low-E Single 0.65 0.25 60.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes8 N
5 E Low-E Single 0.65 0.25 30.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes9 N
6 E Low-E Single 0.65 0.25 6.7 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes9 N
7 E Low-E Single 0.65 0.25 6.7 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes9 N
8 E Low-E Single 0.65 0.25 20.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes9 N
9 W Low-E Single 0.65 0.25 30.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes10 N
10 W Low-E Single 0.65 0.25 15.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes13 N
11 S Low-E Single 0.65 0.25 12.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes14 N
10/29/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 462 ft² 462 ft² 31 ft 8 ft 11______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
1610.7 588.42.000345Wholehouse .135166.29Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 16 30 kBtu/hr 900 cfm 0.8______sys#1Split1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.98 50 gal 60.9 gal 120 deg None______None Attic
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 140 ft² Attic 14 ft² Default Leakage Garage (Default) c______1 1 (Default) c
10/29/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3
Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING ROOM
Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER DINING RO
Default(8 lbs/sq.ft.f t ² f t 0.3 NOOK
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY
Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC
Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 HALL
10/29/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������