Loading...
HomeMy WebLinkAboutJAAR- SPRUCE REVISION- ENERGY CALC (1)EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 610/29/2020 4:43 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY JAAR ENTERPRISES, LLC.JAAR ENTERPRISES LLC- 5809 SPRUCE DR Street: City, State, Zip: FORT PIERCE , FL , 34982 5809 SPRUCE DRIVE Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 1781 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.65 216.33 ft² SHGC=0.25 N/A f t ² N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 1781.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 1499.00 ft² b. Frame - Wood, Adjacent R=11.0 248.00 ft² c. N/A R=f t ² 10. Ceiling Types a. Roof Deck (Unvented)R=20.0 1781.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: Garage 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:1.500 ft. Area Weighted Average SHGC:0.250 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None 3 (216.3 sqft.) (1747.0 sqft.) (1781.0 sqft.) (1781.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 30.0 SEER:16.00 Efficiency k B t u / h r Efficiency 27.0 COP:1.00 f t ² R 6 140 EF: 0.980 Glass/Floor Area: 0.121 Total Proposed Modified Loads: Total Baseline Loads: 62.57 63.20 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 11-3-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY JAAR ENTERPRISES, LLC. 1 JAAR ENTERPRISES LLC- 5 Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 1781 3 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , 34982 FORT PIERCE , St. Lucie 5809 SPRUCE DRIVE Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 1781 19328 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 BEDROOM 2 188 1504 No 0 1 Yes Yes1 Yes 2 CLST 2 20 160 No 0 Yes Yes1 Yes 3 BATH 2 50 400 No 0 Yes Yes1 Yes 4 CLST 3 20 160 No 0 Yes Yes1 Yes 5 BEDROOM 3 169 1352 No 0 1 Yes Yes1 Yes 6 LIVING ROOM 300 4200 No 0 Yes Yes1 Yes 7 FOYER DINING RO 240 3360 No 0 Yes Yes1 Yes 8 NOOK 130 1820 No 0 Yes Yes1 Yes 9 KITCHEN 130 1820 Yes 0 Yes Yes1 No 10 LAUNDRY 70 560 No 0 Yes Yes1 Yes 11 MASTER BEDROO 280 2520 No 0 1 Yes Yes1 Yes 12 M WIC 54 432 No 0 Yes Yes1 No 13 M BATH 109 872 No 0 Yes Yes1 Yes 14 HALL 21 168 No 0 Yes Yes1 No # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 188 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -027 ft BEDROOM 2 2 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 2 3 50 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH 2 4 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 3 10/29/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 5 169 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -026 ft BEDROOM 3 6 300 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -015 ft LIVING ROOM 7 240 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -015 ft FOYER DINING 8 130 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -010 ft NOOK 9 130 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft KITCHEN 10 70 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft LAUNDRY 11 280 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -035 ft MASTER BEDRO 12 54 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M WIC 13 109 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -09 ft M BATH 14 21 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Composition shingles 1992 ft² Medium 0.3 20 26.6______No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 1781 ft² N N0 # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented)0 188 ft² 0.1 Wood______BEDROOM 2 Blown 2 Under Attic (Unvented)0 20 ft² 0.1 Wood______CLST 2 Blown 3 Under Attic (Unvented)0 50 ft² 0.1 Wood______BATH 2 Blown 4 Under Attic (Unvented)0 20 ft² 0.1 Wood______CLST 3 Blown 5 Under Attic (Unvented)0 169 ft² 0.1 Wood______BEDROOM 3 Blown 6 Under Attic (Unvented)0 300 ft² 0.1 Wood______LIVING ROOM Blown 7 Under Attic (Unvented)0 240 ft² 0.1 Wood______FOYER DINING Blown 8 Under Attic (Unvented)0 130 ft² 0.1 Wood______NOOK Blown 9 Under Attic (Unvented)0 130 ft² 0.1 Wood______KITCHEN Blown 10 Under Attic (Unvented)0 70 ft² 0.1 Wood______LAUNDRY Blown 11 Under Attic (Unvented)0 280 ft² 0.1 Wood______MASTER BEDRO Blown 12 Under Attic (Unvented)0 54 ft² 0.1 Wood______M WIC Blown 13 Under Attic (Unvented)0 109 ft² 0.1 Wood______M BATH Blown 14 Under Attic (Unvented)0 21 ft² 0.1 Wood______HALL Blown 10/29/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0BEDROOM 2 00014 8N Concrete Block - Int Insul 0.30Exterior112.0 ft² ____ 2 4.1 0BEDROOM 2 00013 8W Concrete Block - Int Insul 0.30Exterior104.0 ft² ____ 3 4.1 0CLST 2 0002 8N Concrete Block - Int Insul 0.30Exterior16.0 ft² ____ 4 4.1 0BATH 2 0005 8N Concrete Block - Int Insul 0.30Exterior40.0 ft² ____ 5 4.1 0CLST 3 0002 8N Concrete Block - Int Insul 0.30Exterior16.0 ft² ____ 6 4.1 0BEDROOM 3 00013 8E Concrete Block - Int Insul 0.30Exterior104.0 ft² ____ 7 4.1 0BEDROOM 3 00013 8N Concrete Block - Int Insul 0.30Exterior104.0 ft² ____ 8 4.1 0LIVING ROO 00015 14W Concrete Block - Int Insul 0.30Exterior210.0 ft² ____ 9 4.1 0FOYER DINI 00015 14E Concrete Block - Int Insul 0.30Exterior210.0 ft² ____ 10 4.1 0NOOK00010 14W Concrete Block - Int Insul 0.30Exterior140.0 ft² ____ 11 4.1 0LAUNDRY0007 8E Concrete Block - Int Insul 0.30Exterior56.0 ft² ____ 12 4.1 0MASTER BE 00017 9S Concrete Block - Int Insul 0.30Exterior153.0 ft² ____ 13 4.1 0MASTER BE 00018 9W Concrete Block - Int Insul 0.30Exterior162.0 ft² ____ 14 4.1 0M BATH 0009 8S Concrete Block - Int Insul 0.30Exterior72.0 ft² ____ 15 11 0M BATH 021 8E Frame - Wood 0.30.1Garage168.0 ft² ____ 16 11 0LAUNDRY010 8S Frame - Wood 0.30.1Garage80.0 ft² ____ #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Wood .2 .1 ft² None______N BEDROOM 2 .1.1 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 W Low-E Single 0.65 0.25 15.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes2 N 2 N Low-E Single 0.65 0.25 6.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes4 N 3 E Low-E Single 0.65 0.25 15.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes6 N 4 W Low-E Single 0.65 0.25 60.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes8 N 5 E Low-E Single 0.65 0.25 30.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes9 N 6 E Low-E Single 0.65 0.25 6.7 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes9 N 7 E Low-E Single 0.65 0.25 6.7 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes9 N 8 E Low-E Single 0.65 0.25 20.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes9 N 9 W Low-E Single 0.65 0.25 30.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes10 N 10 W Low-E Single 0.65 0.25 15.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes13 N 11 S Low-E Single 0.65 0.25 12.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes14 N 10/29/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 462 ft² 462 ft² 31 ft 8 ft 11______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1610.7 588.42.000345Wholehouse .135166.29Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 30 kBtu/hr 900 cfm 0.8______sys#1Split1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.98 50 gal 60.9 gal 120 deg None______None Attic FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 140 ft² Attic 14 ft² Default Leakage Garage (Default) c______1 1 (Default) c 10/29/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3 Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING ROOM Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER DINING RO Default(8 lbs/sq.ft.f t ² f t 0.3 NOOK Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 HALL 10/29/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������