Loading...
HomeMy WebLinkAboutEnergy Calcs-Burns Updated 11-2-2020FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BURNS ADDITION Builder Name: Street: 2805 N Al Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types (430.0 sqft.) Insulation Area 2_ Single family or multiple family Single -family a. Frame - Wood, Exterior R=19.0 430.00 ftz 3. Number of units, if multiple family 1 b. NIA R- ft2c. NIA 4. Number of Bedrooms (Bedrms In Addition) 1(0) d. N/A R= ft2 R= ft2 5. Is this a worst case? No 10. Ceiling Types (204.0 sgft.) Insulation Area a. Roof Deck (Unvented) R-20.0 204.00 ft, 6. Conditioned floor area above grade (ft2) 204 b. NIA R= ft2 Conditioned floor area below grade (ftp) 0 c. NIA R= ft2 7. Windows(37.8 sgff.) Description Area 11, Ducts R ftp a. U-Factor: Dbl, default 20.00 ft2 SHGC: Clear, default b. U-Factor; Dbl, default 17.78 ft= 12. Cooling systems kBtulhr Efficiency SHGC: Clear, default a. Central Unit 9.0 SEER:18.00 c. U-Factor: NIA ttz SHGC: d. 13. Heating systems kBtulhr Efficiency SHGCC:: NIA ft2 a. Electric Heat Pump 17.0 HSPF:8.50 SHG Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.488 14. Hot water systems - 8. Floor Types (204.0 sgft.) Insulation Area a. Eiectric Cap: 40 gallons a. Slab-On-Grade Edge Insulation R=0.0 204.00 ftz EF: 0.980 b. Conservation features b. NIA R= ft2 None c. NIA R= ft2 15. Credits None Glass/Floor Area: 0.185 Total Proposed Modified Loads: 9.48 ���� Total Baseline Loads: 11.74 I hereby certify that the plans and specifications covered by Review of the plans and _i1iE S'r this calculation are in Compliance with the Florida Energy specifications covered by this ,q Code. calculation indicates compliance �,, ° X% with the Florida Energy Code. PREPARED Y: -'� Before construction is completed w ` DATE: this building will be inspected for A. compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. 1 bbn wr OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with 8403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). (Exception may apply) 11/212020 9:31 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM 8405-2017 INPUT SUMMARY CHECKLIST REPORT Design Temp Int Design Temp Heating Design Daily Temp PROJECT TMY Site Title: BURNS ADDITION Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 204 Lot # Owner Name: Total Stories: 1 BlocklSubdimsion: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 2805 N A1A Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family NewlExisting: Addition FL Comment: Bedrooms InfilID Finished Cooled Heated 1 BATH CLIMATE / v Design Location Design Temp Int Design Temp Heating Design Daily Temp TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ VERO_BEACH_MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 Entire House 204 2040 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BATH 40 400 No 0 1 Yes Yes Yes 2 WIC 25 250 No 0 1 Yes Yes Yes 3 BEDROOM 139 1390 No 0 7 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R -Value Area Joist R -Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BATH 5 ft 0 40 ft2 -10 _-__ 0 2 Slab -On -Grade Edge Insulation WIC 3 ft 0 25 ftz 1 0 0 3&@b -On -Grade Edge Insulation BEDROOM 35 ft 0 139 ft2 __-_ 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 208 ft2 0 ft2 Light N 0.6 No 0,9 No 20 11.8 ATTIC € Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 204 ft2 N N 111212020 9:31 AM EnergyGaugeC) USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R -Value Ins Type Area Framing Frac Truss Type 1 Under Attie (Unvented) BATH 0 Blown 40 ft' 0.1 Wood 2 Under Attic (Unvented) WIC 0 Blown 25ft2 0.1 Wood 3 Under Attic (Unvented) BEDROOM 0 Blown 139 ft2 0,1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 S Exterior Frame - Wood BATH 19 5 0 10 0 50.0 ft2 0 0.1 0.6 0 2 N Exterior Frame - Woad W IC 19 3 0 10 0 30.0 ft2 0 0.1 0.6 0 3 N Exterior Frame- Wood 13EDROOM 19 11 0 10 0 110.0112 0 01 0.6 0 4 E Exterior Frame - Wood BEDROOM 19 13 0 10 0 130.0 ft2 0 0.1 0.6 0 5 S Exterior Frame - Wood BEDROOM 19 11 0 10 0 110.0 ft2 0 0.1 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. Wall # Ornt ID Frame Panes NFRC U -Factor SHGC Imp Area Overhang Depth Separation Int Shade Screeninc 1 N 3 Metal Low -E Double No 0,8 0.7 N 17.8 ft' 2 rt 0 in 1 ft 4 in None None 2 E 4 Metal Lola.^ -E Double No 1.01 (1.3 N 20.0 ft' 2 ft e in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 238 13.07 24.57 .1685 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Purnp/Supplemen Split Single HSPF:8.5 17 kBVhr 1 Ductless COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Su pplernental for a Split Single SPF -R, 18 9 kBtLlhr 270 efm 0.8 1 Ductless HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Exterior 0.98 40 gal 55.1 gal 120 deg None 111212020 9.31 AEN EnergyGnugeCR) USA 8.0.02 (Rev. 1) - FlaRes2017 FBG 6th Edition (2017) Compliant software Page 3 of 4 FORM 8405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Coltector Model # Area Volume FEF None None ft2 TEMPERATURES Programable Thermostat: N Ceiling Fans: c a' o Ing Jan Heating Jan Venting H Feb Feb Mar Mar A r Appr Ma May Jun Jun Jul Jul rj X AugSe r i AuSep Oct Oct Nov Nov Dec Dec Jan Feb lXl [X] rV1ar A r I [ Ma Jun Jul Aug Se Oct Nov j Dec Thermostat Schecule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 8o 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 80 80 80 80 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM PM 65 68 65 68 65 65 65 65 65 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM PM 65 65 65 65 65 65 65 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibslsq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 lbslsq.ft. ft= ft 0.3 M WIC 'I Default(8 Ibs/sq.ft. P2 ft 0.3 M WIC 2 Default(8 lbs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8 Ibslsq.ft. ft, ft 0.3 FOYER Default(8lbs/sq.ft. ft2 ft 0.3 DINING ROOM Default(8 Ibslsq.ft. ft2 ft 0.3 LIVING ROOM Default(8 lbslsq.ft. ftz ft 0.3 KITCHEN Default(8 Ibslsq.ft. ft, ft 0.3 LAUNDRY ROOM Default(8 lbs/sq.ft. ftz ft 0.3 HALL Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibstsq.ft. ft2 ft 0.3 CLST 2 Default(8 lWsq.ft. ft2 tt 0.3 BATH 2 Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 lbs/sq.ft. 1t, ft 0.3 CLST 4 Default(8 lbs/sq.ft. ft= ft 0.3 CLST 3 Default(8 Ibslsq.ft. W ft 0.3 BEDROOM 4 Default(8 lbslsq.ft, ft2 ft 0.3 BATH 3 Default(8 lbs/sq.ft. ft2 ft 0.3 NOOK Default(8Ibs/sq.ft. ft2 ft 0.3 AHU CLST Default(8 lbs/sq.ft. 0 ftz Oft 0.3 M TOILET 11/2/2020 9'31 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 This document was created with Win2PDF available at http://Www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or noxi-cornrnercial use only. This page will not be added after purchasing Win2PD . 2417 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: BURNS ADDITION Builder Name: Street: 2805 N AllA Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y Owner: Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce = t� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the air barrier shall be sealed. not be used as a sealing material. Ceiiinglattic The air barrier in any dropped ceilinglsoffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed, shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be seated. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shat} be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including above -garage maintain permanent contact with the underside of and cantilevered floors) subfloor decking, or floor framing cavity insulation shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the dryWall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Dipina and wirin . Showerttub The air barrier Installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be seated sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used tofill voids between fire sprinkler cover lates and walls or ceilin s. a_ In additinn incnarfinn of I vv ur�llc chnSl ha n 1 .� .__�___..... _.. ...y ..-"— ,a., W — ­­­ -11? L- F11 M1VI1S Vd jt u-4uu. 11/212020 9:31 AM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th 'Edition (2017) Compliant 5ottware Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX` = 81 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R 2. Single-family or multiple -family 2. _ Single-family b) Return ducts R c) AHU location 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 1 13. Cooling system: Capacity 9.0 5. Is this a worst case? (yes/no) 5. No a) Split system SEER b) Single package SEER 18.0 c) Ground/water source SEER/COP- 6. Conditioned floor area (sq. ft.) 6. 204 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a, 0.911 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.488 14. Heating system: Capacity 17.0 c) Area 7c. 37.8 a) Spirt system heat pump HSPF 8.5 b) Single package heat pump HSPF B. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b, NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R -value) ga. 0.0 b) Wood, raised (R -value) 9b. 15. Water heating system c) Concrete, raised (R -value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A, Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R -value) 10A1. 19.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R -value) 10A2. f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R -value) 1081. 2. Masonry (Insulation R -value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c, d) Multizone cooling credit d) Radiant barrier installed 11d. e) Multizone heating credit f) Programmable thermostat No 'Label required by Section R303.1,3 of the Florida Building Code, Energy Conservation, if not DEFAULT. certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signatu Address of New Home: 2805 N AIA CitylFL Zip: FORT PIERCE FL 11!212020 9.31!39 AM EnergyGauge(D USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1