Loading...
HomeMy WebLinkAboutProject InformationRight -Suite Commercial Short Form wAh 1 Project Information For: TURNER INDUSTRIAL 5000 ORANGE AVE., FT. PIERCE, FLORIDA, Htg Clg Htg Clg Outside db (OF) 42 89 Inside db (OF) 70 75 Outside RH (%) - 62 Inside RH (%) - 50 Outside wb (OF) - 78 Inside wb (OF) - 63 Daily range (OF) - 15 Design TD (OF) 28 14 Moisture dill. (gr/lb) - 61 Heating Equipment Make Model Type Efficiency / HSPF Heating Input Heating Output Humidifier Leaving Air Temp Actual Heating Fan 0.0 0.0 MBtuh 0.0 MBtuh 0.0 gpd 70.0 OF 1544 cfm Equipment Location System Type Fan Motor Heat Type Fan & Motor Combined Efficiency Static Pressure Across Fan Cooling Equipment Make Model Type COP/EER/SEER Sensible Cooling Latent Cooling Total Cooling Leaving Air Temp Actual Cooling Fan Ahl PEAKCV BLOWTHRU 0.0 % 0.0 in H2O GOLDSTAR GWHD6507R 10.0 4603.0 MBtuh 490.0 MBtuh 5093.0 MBtuh 55.0 OF 1544 cfm NAME Area Heat Sensible Latent Htg Clg Time T Loss Gain Gain cfm cfm NEW SPACE 128 4618 4603 490 243 209 Jul 1700 EXISTING SPACE 1063 25058 29326 2408 1300. 1334 Jul 1700 Ah1 1191 j 29675 j 33929 j 2898 j 1544 j 1544 Jul 1700 wng htsoft Right -Suite Commercial 5.8.13 RSC51450 2007-Oct-0B 11:30:47 C:\Program Files\Wrightsoft HVAC\TURNER MACHINE-GRIMES.rsc Page 1 Right -Suite Commercial Load Summary �Ah 1 Project Information For: TURNER INDUSTRIAL 5000 ORANGE AVE., FT. PIERCE, FLORIDA, 1. DESIGN CONDITIONS at Jul 1700 Inside: 75 OF Outside: 89 OF RH: 50 % Moisture: 61.5 gr/lb 2. SOLAR RADIATION THROUGH GLASS 3. TRANSMISSION GAINS Sensible Walls: 21160 Glass: 0 Doors: 0 Partitions: 0 Floors: 0 Roofs/Ceilings: 3263 Return Air Ceiling: 0 4. INTERNAL HEAT GAIN Sensible Occupants: 250 Lights: 7325 Motors: 0 Appliances: 0 5. INFILTRATION: Outside air cfm: 6. SUBTOTAL: Space load 7. SUPPLY DUCT 8. SUBTOTAL: Bldg comp's and supply duct Actual cfm: 1544 at Supply TD: 9. VENTILATION: Make-up air cfm: 10. RETURN AIR LOAD: Lighting & roof (net) 11. RETURN DUCT 12. TOTAL LOADS ON EQUIPMENT Peak load at Jul 1700 TD: 14 OF Mult: 1.0 Ins.wb Sensible 0 24424 Latent 7575 200 - 0 - 64 942 32941 988 33929 20 - 0 0 0 0 33929 -----.—HEATING. LOAD 13. DESIGN CONDITIONS Mult: Inside: 70 OF Outside: 42 OF TD: 14. TRANSMISSION LOSSES Walls: 20160 Glass: 0 Doors: 0 Partitions: 0 Floors: 3266 Roofs/Ceilings: 1334 Return Air Roof: 0 15. INFILTRATION: Outside air cfm: 16. SUBTOTAL: Building components 17. SUPPLY DUCT: 18. VENTILATION: Make-up air cfm: 19. HUMIDIFICATION 20. RETURN DUCT 21. TOTAL HEATING LOAD ON EQUIPMENT 95 0 1.0 28 OF 24760 2932 27692 831 0 1153 0 29675 63 OF Latent 200 2698 2898 0 2898 wr1ghtsoft Right -Suite Commercial 5.8.13 RSC51450 2007-Oct-08 11:30:47 CAProgram Files\Wrightsoft HVAC\TURNER MACHINE-GRIMES.rsc Page 1