HomeMy WebLinkAboutProject Summary1
Florida Energy, Efflciency.Code For Building Construction
Florida tbparthient of Community,Affairs
EnergyGauge FLA/COM 2004 v3.00 -- Form 40OC-2004
Method C: Prescriptive Compliance for Commercial Buildings
Effective December 8, 2006
PROJECT SUMMARY
Short Desc: TURNER INDUSTRIAL/4/ M flp7/2Lf 5� Description: TURNER INDUSTRIAL
Owner: C571� A) ✓el)r � l
Addressl: 55 co /0J1W(9� //� W City: FT. PIERCE
Address2: t4/Lf /- / C%�j rli 3 v 7/, 7 State: FLhere
Zip: 0
Type: Office Class: Addition to existing Building
Jurisdiction: FORT PIERCE, ST LUCIE COUNTY, FL (661100)
Cond Area: 130 SF Cond & UnCond Area: 130 SF
No of Storeys: 1 Area entered from Plans 0 SF
Permit No: 0 Max Tonnage 0.4
If different, write in:
10/8/2007 EnergyGauge FLA/COM 2004 v3.00 1
Compliance Summary
11 Component Design Criteria Result 11
ENVELOPE PRESCRIPTIVE
LIGHTING POWER
LIGHTING CONTROLS
EXTERNAL LIGHTING
HVAC SYSTEM
PLANT
WATER HEATING SYSTEMS
PIPING SYSTEMS
Met all required compliance from Check List?
120.0
PASSES
142.6 PASSES
PASSES
None Entered
PASSES
None Entered
None Entered
None Entered
Yes/No/NA
RTANT NOTE: An input report of this design building must be submitted
with this Compliance Report.
10/8/2007 EnergyGauge FLA/COM 2004 v3.00 2
I hereby certify that the plans
Florida Energy Code
CERTIFICATIONS
this calculation are in compliance with the
Prepared By: V Zu/ " Building Official:
Date: Date:
I certify that this building is in compliance with the FLorida Energy Efficiency Code
Owner Agent: Date:
If Required by Florida law, I hereby certify (*) that the system design is in compliance with the FLorida
Energy Efficiency Code
Architect: Reg No:
Electrical Designer: Reg No:
Lighting Designer: Reg No:
Mechanical Designer: Reg No: 00cd & f�
Plumbing Designer: Reg No:
(*) Signature is required where Florida Law requires design to be performed by registered design
professionals. Typed names and registration numbers may be used where all relevant information is
contained on signed/sealed plans.
Project: TURNER MACHINE
Title: TURNER MACHINE
Type: Office
(WEA File: DAYTONABEACH.TMY)
Method C: Prescriptive Envelope Compliance
Zone Description Design Limit Meet Req.
Glass
PrOZol
Percent glass Max allowed
.000
50.000 Yes
NORTH
PrOZol
Exterior Wall: UValue Max allowed
.049
0.089 Yes
EAST
PrOZol
Exterior Wall: UValue Max allowed
.049
0.089 Yes
Skylights
PrOZol
Percent Skylight Max allowed
.000
5.000 Yes
ROOF
PrOZol
Exterior Roof UValue Max allowed
.033
0.034 Yes
Meets Prescriptive Envelope Requirements -- PASSES
10/8/2007 EnergyGauge FLA/COM 2004 v3.00 3
External Lighting Compliance
Description
Category Allowance Area or Length ELPA CLP
(W/Unit) or No. of Units (W) (VV)
(Sgft or ft)
None
Project: TURNER MACHINE
Title: TURNER MACHINE
Type: Office
(WEA File: DAYTONABEACH.TMY)
Lighting Power Compliance
Space Ashrae Description
ID
Area Height No. of Design Effective Allowance
(sq.ft) (ft) Spaces (W) (W) (W)
OFFICE 17 Office - Enclosed 130 9.0 1 120 120 143
Design 120 (W)
Effective: 120 (V)
Allowance: 142.56 (W)
PASSES
Project: TURNER MACHINE
Title: TURNER MACHINE
Type: Office
(WEA File: DAYTONABEACH.TMY)
Lighting Controls Compliance
Acronym Ashrae Description
Area No. of Design Min Compli-
ID
(sq.ft) Tasks CP CP ance
OFFICE 17 Office - Enclosed
130 1 1 1 PASSES
PASSES
10/8/2007 EnergyGauge FLA/COM 2004 v3.00
Project: TURNER MACHINE
Title: TURNER MACHINE
Type: Office
(WEA File: DAYTONABEACH.TMY)
System Report Compliance
PrOSyl System 1
Through the wall
No. of Units
AirConditioner Single
Packau .
1
Component Category
Capacity Design Eff Design
IPLV Comp-
Eff Criteria IPLV
Criteria liance
Cooling System Thru the Wall A/C < 30,000
11.00 10.60
PASSES
Btu/h Single Package
Heating System Electric Furnace
1.00 1.00
PASSES
Air Handling Air Handler (Supply) -
0.80 0.90
PASSES
System -Supply Constant Volume
PASSES
0,
Plant Compliance
Description Installed Size Design Min Design Min Category Comp
No Eff Eff IPLV IPLV liance
None
Water Heater Compliance
Design Min Design Max Comp
Description Type Category Eff Eff Loss Loss liance
None
10/8/2007 EnergyGauge FLA/COM 2004 v3.00 5
Piping System Compliance
Category
Pipe Dia Is Operating Ins Cond Ins Req Ins
Compliance
[inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in]
[F] .SF.F]
None
Project: TURNER MACHINE
Title: TURNER MACHINE
Type: Office
(WEA File: DAYTONABEACH.TMY)
Other Required Compliance
Category
Section
Requirement (write N/A in box if not applicable)
Check
Infiltration
406.1
Infiltration Criteria have been met
System
407.1
HVAC Load sizing has been performed
Ventilation
409.1
Ventilation criteria have been met
❑
ADS
410.1
Duct sizing and Design have been performed
T & B
410.1
Testing and Balancing will be performed
Motors
414.1
Motor efficiency criteria have been met
Lighting
415.1
Lighting criteria have been met
O & M
102.1
Operation/maintenance manual will be provided to owner
Roof/Ceil
404.1
R-19 for Roof Deck with supply plenums beneath it
Report
101
Input Report Print -Out from EnergyGauge FlaCom attached?
10/8/2007 EnergyGauge FLA/COM 2004 v3.00
EnergyGauge FLAXOM 2004 v3.00
INPUT DATA REPORT
Project Name: TURNER INDUSTRIAL
Project Title: TURNER INDUSTRIAL
Address:
State: FLhere
Zip: 0
Owner:
Project Information
Orientation: North
Building Type: Office
Building Classification: Addition to existing Building
No.of Storeys: ]
GrossArea: 130 SF
Zones
No Acronym Description Type
Area
[sf]
Multiplier
Total Area
[sf]
1 PrOZol Zone 1 CONDITIONED
129.6
1
129.6 ❑
Spaces
No Acronym Description Type Depth
[ft]
Width Height Multi
[ft] [ft] plier
Total Area
[sf]
Total Volume
[cf]
10/8/2007 EnergyGauge FLA/COM 2004 v3.00 1
In Zone: PrOZol
1 OFFICE
Zo0Sp1 Office - Enclosed
8.00
16.20
9.00
1
129.6
1166.4 0]
Lighting
No
Type Category
No. of
Watts per
Power
Control Type
No.of
Luminaires
Luminaire
[W]
Ctrl pts
In Zone: PrOZol
In Space: OFFICE
1
Compact Fluorescent General Lighting
2
60
120
Manual On/Off
1 El
Walls
No Description
Type Width H (Effec) Multi
Area DirectionConductance
Heat
Dens. R-Value
[ft]
[ft] plier
[sf]
[Btu/hr. sf. F]
Capacity
[lb/cf] [h.sf.F/Btu]
[Btu/sf.F]
In Zone: PrOZol
1 PrOZolWal
STEEL SIDING, 16.20
8.00 1
129.6
North
0.0489
1.227
13.42 20.5 ❑
2X4, R-11, GYP.
BRD.
2 PrOZo 1 Wa2
STEEL SIDING, 8.00
8.00 1
64.0
North
0.0489
1.227
13.42 20.5 ❑
2X4, R-11, GYP.
BRD.
Windows
No
Description Type Shaded
U SHGC Vis.Tra
W
H (Effec)
Multi
Total Area
[Btu/hr sf F]
IN
[ft]
plier
[sf]
In Zone:
In Wall:
EJ
10/8/2007 EnergyGauge FLA/COM 2004 v3.00
Doors
No Description
Type
Shaded? Width H (Effec) Multi
Area
Cond. Dens. Heat Cap. R-Value
[ft] [ft]
plier
[sf]
[Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.FBtu]
In Zone:
In Wall:
El
Roofs
No Description
Type
Width H (Effec) Multi
Area
Tilt
Cond. Heat Cap Dens. R-Value
N [ft] plier
[sf]
[deg]
[Btu/hr. Sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu]
In Zone: PrOZol
1 PrOZo1Rfl
METAL BLDG.
16.20 8.00 1
129.6
0.00
0.0330 0.81 3.48 30.3
❑
ROOF, R-19
Skylights
No Description Type
U SHGC Vis.Trans
W
H (Effec) Multiplier Area Total Area
[Btu/hr sf F]
[ft]
A [Sf] [Sf]
In Zone:
In Roof:
El
Floors
No Description
Type
Width H (Effec) Multi
Area
Cond. Heat Cap. Dens. R-Value
[ft] [ft] plier
[sf]
[Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu]
In Zone: PrOZol
1 PrOZo1F11
1 ft. soil, concrete
16.20 8.00 1
1-29.6 0.1745 54.00 108.00 5.73
❑
floor, carpet and
rubber pad
10/8/2007 EnergyGauge FLA/COM 2004 v3.00
Systems.
PrOSyl System 1
Through the wall AirConditioner No. Of Units I
Single Package
Component Category
Capacity Efficiency IPLV
1 Cooling System (Thru the Wall A/C < 30,000 Btu/h
Single Package)
2 Heating System (Electric Furnace)
3 Air Handling System -Supply (Air Handler (Supply) -
Constant Volume)
5000.00 11.00
27000.00 1.00
1500.00 0.80
El
Plant
Equipment Category
Size Inst.No Eff. IPLV
Water Heaters
W-Heater Description Capacit3Cap.Unit
I/P Rt. Efficiency Loss
Ext-Lighting
Description Category No. of Watts per Area/Len/No. of units Control Type Wattage
Luminaires Luminaire [sVft/No] [W]
10/8/2007 EnergyGauge FLA/COM 2004 v3.00
Piping
No Type Operating Insulation Nomonal pipe Insulation Is Runout?
Temperature Conductivity Diameter Thickness
[F] [ Btu-in/h.sf.F] [in] [in]
K
Fenestration Used
Name Glass Type No. of Glass SHGC VLT
Panes Conductance
[Btu/h.sf.F]
Materials Used
Mat No
Acronym
Description
Only R-Value
RValue
Thickness
Conductivity
Density
SpecificHeat
Used
[h.sf.F/Btu]
[ft]
[Btu/h.ft.F]
[lb/cf]
[Btu/1b.F]
187
Mat1187
GYP OR PLAS
No
0.4533
0.0417
0.0920
50.00
0.2000
❑
BOARD,1/2IN
178
Mat1178
CARPET W/RUBBER PAD
Yes
1.2300
❑
265
Mat1265
Soil, 1 ft
No
2.0000
1.0000
0.5000
100.00
0.2000
❑
48
Mat148
6 in. Heavyweight concrete
No
0.5000
0.5000
1.0000
140.00
0.2000
❑
23
Mat123
6 in. Insulation
No
20.0000
0.5000
0.0250
5.70
0.2000
❑
4
Mat14
Steel siding
No
0.0002
0.0050
26.0000
480.00
0.1000
❑
1001
ApLbMat1001
BUILT-UP ROOFING,
No
0.3366
0.0313
0.0930
70.00
0.3500
❑
3/81N
1003
ApLbMat1003
R-30 Generic Insulation
No
30.0000
0.6548
0.0218
0.30
0.2000
❑
10/8/2007 EnergyGauge FLA/COM 2004 v3.00 5
Constructs Used
No Name Simple Massless Conductance Heat Capacity Density RValue
Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu]
1038 STEEL SIDING, 2X4, R-11, GYP. BRD. No No 0.05 1.23 13.42 20.5 ❑
Layer
Material Material
Thickness
Framing
No.
[ft]
Factor
1
23 6 in. Insulation
0.5000
0.000
❑
2
187 GYP OR PLAS BOARD,1/21N
0.0417
0.000
❑
3
4 Steel siding
0.0050
0.000
❑
No Name
Simple
Massless Conductance Heat Capacity
Density RValue
Construct
Construct [Btu/h.sf.F]
[Btu/sf.F]
[lb/cf] [h.sf.FBtu]
1040 METAL BLDG.
ROOF, R-19 No
No 0.03
0.81
3.48 30.3 ❑
Layer
Material
Material
Thickness
Framing
No.
[ft]
Factor
1
1001
BUILT-UP ROOFING, 3/81N
0.0313
0.000
❑
2
1003
R-30 Generic Insulation
0.6548
0.000
❑
No Name
Simple
Massless Conductance Heat Capacity
Density RValue
Construct
Construct [Btu/h.sf.F]
[Btu/sf.F]
[lb/cf] [h.sf.FBtu]
1057 1 ft. soil, concrete floor, carpet and rubber pad No
No 0.17
54.00
108.00 5.7 ❑
Layer
Material
Material
Thickness
Framing
No.
[ft]
Factor
1
265
Soil, 1 ft
2.0000
0.000
❑
2
48
6 in. Heavyweight concrete
0.5000
0.000
❑
3
178
CARPET W/RUBBER PAD
0.000
❑
10/8/2007 EnergyGauge FLA/COM 2004 v3.00 6