Loading...
HomeMy WebLinkAboutProject Summary1 Florida Energy, Efflciency.Code For Building Construction Florida tbparthient of Community,Affairs EnergyGauge FLA/COM 2004 v3.00 -- Form 40OC-2004 Method C: Prescriptive Compliance for Commercial Buildings Effective December 8, 2006 PROJECT SUMMARY Short Desc: TURNER INDUSTRIAL/4/ M flp7/2Lf 5� Description: TURNER INDUSTRIAL Owner: C571� A) ✓el)r � l Addressl: 55 co /0J1W(9� //� W City: FT. PIERCE Address2: t4/Lf /- / C%�j rli 3 v 7/, 7 State: FLhere Zip: 0 Type: Office Class: Addition to existing Building Jurisdiction: FORT PIERCE, ST LUCIE COUNTY, FL (661100) Cond Area: 130 SF Cond & UnCond Area: 130 SF No of Storeys: 1 Area entered from Plans 0 SF Permit No: 0 Max Tonnage 0.4 If different, write in: 10/8/2007 EnergyGauge FLA/COM 2004 v3.00 1 Compliance Summary 11 Component Design Criteria Result 11 ENVELOPE PRESCRIPTIVE LIGHTING POWER LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? 120.0 PASSES 142.6 PASSES PASSES None Entered PASSES None Entered None Entered None Entered Yes/No/NA RTANT NOTE: An input report of this design building must be submitted with this Compliance Report. 10/8/2007 EnergyGauge FLA/COM 2004 v3.00 2 I hereby certify that the plans Florida Energy Code CERTIFICATIONS this calculation are in compliance with the Prepared By: V Zu/ " Building Official: Date: Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (*) that the system design is in compliance with the FLorida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer: Reg No: 00cd & f� Plumbing Designer: Reg No: (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. Project: TURNER MACHINE Title: TURNER MACHINE Type: Office (WEA File: DAYTONABEACH.TMY) Method C: Prescriptive Envelope Compliance Zone Description Design Limit Meet Req. Glass PrOZol Percent glass Max allowed .000 50.000 Yes NORTH PrOZol Exterior Wall: UValue Max allowed .049 0.089 Yes EAST PrOZol Exterior Wall: UValue Max allowed .049 0.089 Yes Skylights PrOZol Percent Skylight Max allowed .000 5.000 Yes ROOF PrOZol Exterior Roof UValue Max allowed .033 0.034 Yes Meets Prescriptive Envelope Requirements -- PASSES 10/8/2007 EnergyGauge FLA/COM 2004 v3.00 3 External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (VV) (Sgft or ft) None Project: TURNER MACHINE Title: TURNER MACHINE Type: Office (WEA File: DAYTONABEACH.TMY) Lighting Power Compliance Space Ashrae Description ID Area Height No. of Design Effective Allowance (sq.ft) (ft) Spaces (W) (W) (W) OFFICE 17 Office - Enclosed 130 9.0 1 120 120 143 Design 120 (W) Effective: 120 (V) Allowance: 142.56 (W) PASSES Project: TURNER MACHINE Title: TURNER MACHINE Type: Office (WEA File: DAYTONABEACH.TMY) Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance OFFICE 17 Office - Enclosed 130 1 1 1 PASSES PASSES 10/8/2007 EnergyGauge FLA/COM 2004 v3.00 Project: TURNER MACHINE Title: TURNER MACHINE Type: Office (WEA File: DAYTONABEACH.TMY) System Report Compliance PrOSyl System 1 Through the wall No. of Units AirConditioner Single Packau . 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Thru the Wall A/C < 30,000 11.00 10.60 PASSES Btu/h Single Package Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.80 0.90 PASSES System -Supply Constant Volume PASSES 0, Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Water Heater Compliance Design Min Design Max Comp Description Type Category Eff Eff Loss Loss liance None 10/8/2007 EnergyGauge FLA/COM 2004 v3.00 5 Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] .SF.F] None Project: TURNER MACHINE Title: TURNER MACHINE Type: Office (WEA File: DAYTONABEACH.TMY) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ❑ ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge FlaCom attached? 10/8/2007 EnergyGauge FLA/COM 2004 v3.00 EnergyGauge FLAXOM 2004 v3.00 INPUT DATA REPORT Project Name: TURNER INDUSTRIAL Project Title: TURNER INDUSTRIAL Address: State: FLhere Zip: 0 Owner: Project Information Orientation: North Building Type: Office Building Classification: Addition to existing Building No.of Storeys: ] GrossArea: 130 SF Zones No Acronym Description Type Area [sf] Multiplier Total Area [sf] 1 PrOZol Zone 1 CONDITIONED 129.6 1 129.6 ❑ Spaces No Acronym Description Type Depth [ft] Width Height Multi [ft] [ft] plier Total Area [sf] Total Volume [cf] 10/8/2007 EnergyGauge FLA/COM 2004 v3.00 1 In Zone: PrOZol 1 OFFICE Zo0Sp1 Office - Enclosed 8.00 16.20 9.00 1 129.6 1166.4 0] Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: OFFICE 1 Compact Fluorescent General Lighting 2 60 120 Manual On/Off 1 El Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [h.sf.F/Btu] [Btu/sf.F] In Zone: PrOZol 1 PrOZolWal STEEL SIDING, 16.20 8.00 1 129.6 North 0.0489 1.227 13.42 20.5 ❑ 2X4, R-11, GYP. BRD. 2 PrOZo 1 Wa2 STEEL SIDING, 8.00 8.00 1 64.0 North 0.0489 1.227 13.42 20.5 ❑ 2X4, R-11, GYP. BRD. Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [sf] In Zone: In Wall: EJ 10/8/2007 EnergyGauge FLA/COM 2004 v3.00 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.FBtu] In Zone: In Wall: El Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value N [ft] plier [sf] [deg] [Btu/hr. Sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: PrOZol 1 PrOZo1Rfl METAL BLDG. 16.20 8.00 1 129.6 0.00 0.0330 0.81 3.48 30.3 ❑ ROOF, R-19 Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] [ft] A [Sf] [Sf] In Zone: In Roof: El Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: PrOZol 1 PrOZo1F11 1 ft. soil, concrete 16.20 8.00 1 1-29.6 0.1745 54.00 108.00 5.73 ❑ floor, carpet and rubber pad 10/8/2007 EnergyGauge FLA/COM 2004 v3.00 Systems. PrOSyl System 1 Through the wall AirConditioner No. Of Units I Single Package Component Category Capacity Efficiency IPLV 1 Cooling System (Thru the Wall A/C < 30,000 Btu/h Single Package) 2 Heating System (Electric Furnace) 3 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 5000.00 11.00 27000.00 1.00 1500.00 0.80 El Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacit3Cap.Unit I/P Rt. Efficiency Loss Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sVft/No] [W] 10/8/2007 EnergyGauge FLA/COM 2004 v3.00 Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F] [ Btu-in/h.sf.F] [in] [in] K Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.sf.F] Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.F/Btu] [ft] [Btu/h.ft.F] [lb/cf] [Btu/1b.F] 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1/2IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 1001 ApLbMat1001 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/81N 1003 ApLbMat1003 R-30 Generic Insulation No 30.0000 0.6548 0.0218 0.30 0.2000 ❑ 10/8/2007 EnergyGauge FLA/COM 2004 v3.00 5 Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1038 STEEL SIDING, 2X4, R-11, GYP. BRD. No No 0.05 1.23 13.42 20.5 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 23 6 in. Insulation 0.5000 0.000 ❑ 2 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ 3 4 Steel siding 0.0050 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1040 METAL BLDG. ROOF, R-19 No No 0.03 0.81 3.48 30.3 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 1001 BUILT-UP ROOFING, 3/81N 0.0313 0.000 ❑ 2 1003 R-30 Generic Insulation 0.6548 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.17 54.00 108.00 5.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 2.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ 10/8/2007 EnergyGauge FLA/COM 2004 v3.00 6