This symbol identifies Life Safety Warnings that should be read
given special attention by all persons installing trusses.
5PAGING NOTE
ALL TRUSSES ARE TO BE SET
AT 2'-0: ON CENTER
EXCEPT AS NOTED
MULTIPLE PLY TRUSSES MUST BE
ASTENED TOGETHER PER ENGINEERING
BEFORE SETTING. REFER TO
ENGINEERING DRAWING TO DETERMINE
IF MULTIPLE PLY.
_i
n
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
_ CONSULT BCSI
30' Span or less & 30' to 60" Span
0 degrees Spreader Bar
or less
1 2
i span approx.
Tg Line
REFER TO BCSI
Truss must be set this way if crane used.
Truss is an example, your truss may not match.
isist crane operator sets truss this way.
11
ag �, Approx 2/3 to
Line 1/2 of Span
REFER TO BCSI
use must be set this way if crane used.
This is an example, truss may not match.
Insist crane operator sets truss this way.
All load bearing walls, headers,
beams & lintels must be in place
at indicated height before trusses
,A are installed. A
AIR HANDLER Na�T"E
UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
U REPRESENTS A HANGER
For Truss to Truss
Connections see
hanger/connector
schedule in engineering
package.
INDICATES LOAD BEARING
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF 9'-0"
ABOVE FINISHED FLOOR
INDICATES LOAD BEARING
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF 14'-11"
ABOVE FINISHED FLOOR
INDICATES LOAD BEARING
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF 18'-5"
ABOVE FINISHED FLOOR
INDICATES LOAD BEARING
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
ATA HEIGHT OF 20'-1'
ABOVE FINISHED FLOOR
Carrying Girder
7
Nails must be as
shown. Guide tabs 0
Dome angle nails.
Do not stand on trusses until they are braced per BCSI &
FLOOR TRUSS NOTES
1. Do not load floor trusses with construction loads such as concrete blocks.
2. Do not install floor trusses upside down, refer to engineering sheets.
3. Install strongbacks per drawing to improve floor truss performance.
4. Apply rigid drywall ceiling directly to bottom chords of floor trusses,
or brace with 2x4 lateral & diagonal bracing spaced per engineering.
5. Chases are shown with dotted lines and may also be placed in other trusses.
Chases must be centered between bearing points, & are not in girder trusses.
6. Review this document to insure mechanicals can pass through floor trusses.
Recommended STRONGBACK for Floor Trusses
Refer to information on truss engineering drawings.
(2) 16d nails @ top & bottom of 2x4 �.
vertical block. W�rO
2x6 (MIN) STRONGBACK restrained at each end. Secure w/(3)16d nails @ each
vertical. Locate STRONGBACK as close to bottom cord as possible.
STRONGBACKS are recommended to MINIMIZE VIBRATION
HANGER SCHEDULE
Use HU52G for 2x4. 5UH4G for 4x2 FX(-.FPT oc, CHr)WM
carried
truss
carrying
truss
han er ID
g
fasteners for
carried truss
fasteners for
carrvinq truss
GIRD
GRA
HUS26
16d
1Dd x 1 1/2"
DA
GRD *
HUS26
16d
10d x 1 1/2"
review Engineering package, for general instructions on installing hangers.
10d=0.148" x 3" 16d=0.162" x 3 1 /2"
10d=0.148" x 1 1 /2"
-------- - - - - --
r
2x6 Bot. Chord L51�= 718„
, I
LOCATION OF HANGER AT "GRD" r
� r
... --------------------------
"A"
I
"r_Rn^ II
SECTION "A-A11
properly nailed to straps & hangers HUS26
FLOOR TRUSS PERFORMANCE CHART
TRUSS ID LENGTH SPAN DEPTH MAX /D LESS
FLA 28- 0- 0 27- 8- 8 2- 1- 0 18 13.3
FLAA 28- 0- 0 27- 8- 8 2- 1- 0 18 13.3
FLB 28- 0- 0 27- 8-12 2- 1- 0 18 13.4
GFA 9-7-1 9-7-1 2-9-8 18 3.5
GFB 9-7-0 9-7-0 2- 9- 8 18 3.5
GFC 1 9-7-0 9-7-0 2-9-8-1 18 3.5
This chart has been included as a tool to help evaluate floor performance. Floor truss performance
is not a safety issue. Bounce and deflection that is acceptable in one building may not be in another.
S/D= SPAN to DEPTH RATIO, shown as a number & graph line. MAX=Maximum S/D recommended.
The higher the S/D and the longer the graph the bouncier the floor will be. The way to improve
performance is for the building designer to reduce the truss span and/or increase truss depth.
Refer to FLOOR PERFORMANCE / REDUCING VIBRATION, attached.
12
upset=11/4" heel=3 718"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 18'-5"
END DETAIL: A
�4'-11"
upset=11/4" heel=4 3/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 14'-11"
END DETAIL: B
12
2x LEDGER BY OTHERS
(TYP.)
END DETAIL: C
END DE.
B A
5
L LL
m
LL
m
LL
--
m
LL
- - -
m
LL
- --
m
LL
--
CO
LL
--
m
J
--
m
J
- - -
m
J
- --
min
LL
--
U.
--
m
LL
--
m
LL
-----
m
LL
m
J
LL
L
LL
GFA GFB GFC
3' 9' 831
3'
RW
2x LEDGER BY OTHERS —�-
U
1 0
U
U
Uil
U
J
U
U
U
U
C)U
U
01
r
32'
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED 8 RETURNED
The legal description of the property where the trusses will be Installed is;
The undersigned acknowledges and agrees;
1. Trusses will be made In strict accordance with this Vuss placement diagram layout,
which is the sole authority for determining successful fabrication of the trusses.2. All
ve been verified
3. Unlesslensions writtenlnotice ilayout Provided by certified mail etile uChamba Truss within an (10)
days of delivery the undersigned agrees that no backcharges will be allowed. In the event
such wrltten notice is fijed, or to Chambers Tetras shall have three (3) bu ness days in which
to begin repairs required, or to substitute other trusses, at Chambers option.
4- The undersigned acknowledges receipt of "BCSI 1-03"summary sheet by 7PI & WTCA.
deliPortion
of them b rs site russ for deli Is to job site s thetsole ahe uthority to datertn ne the sultab8 i of the Job sis site sul te of ale r
portion of the job site for delivery. Chambers Tru$s will be responsible for dump delivery only.
The buyer Is responsible for additional delivery expenses if Chambers Truss has alive
redeliver
because Job site Is not prepared for delivery or buyer le not prepared for delivery oft russes.
Buyer Is responsible to Chambers Truss for towing costs due to site co f or. else.
8. Price as shown in paragraph 7 below is subject to change If any changes are made In
this layout. A SM per hour fee for revisions may be charged n Chambers Trees.
7. This Is r PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no
agreement a reasonable price. Invoice will be made on delivery and paid within terms of net
on delivery. Invoice may be made at scheduled date of delivery if buyer cannot accept
delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss reasonable
attorney's fee for collections In event of payment not timely made. 1-12 % per month service
charge will be added for all sums not paid within terms.
8. Signature
eement to al terms herein.
9. nconsideration'aof Chambers Truss ending tcredit fls anhere on this sheet consitutes orrthis mat hall the undersigned
unoondigonally guarantees payment when due of any and all indebtedness owed to
Chambers Truss by any entity receiving material and the undersigned agrees to pay such
Indebtedness Including atto
recipient. rneys fees, if default in payment for material be made by the _
10. In the event of any
gation
ng
ement
e items furnished
or payments referred to herein, n, the parties lagree ethat the sole v venue for any such action will
be Saint Lucie County, Florida.
11. Design responsibilities are per -National Standard And Recommended Guidelines On
Responsibilities For Construction Using Metal Plate Connected Wood Trusses
ANSI/TPIIWTCA 4-201 _
DATED
SIGNED - - �-
FOR
TIT c � ---'
A maybe 4l...... r"BCSI1-03 7dn
Multiple plytrusses must be fastened togethineeringeforetheyareset;failure to do so can resuollapse.Temporary and permanent bracing are requiresave life
and property and Is the responsibility of tector.Studythecontents of the information packet Idelivery
before setting trusses.
Trusses mustbesetand braced perdesign m Prevent hJury8 damage,
Trusses must be set plumb and square
Do not set bunks or stack of plywood, rooting material or any
other concentrated loads on trusses, this can cause collapse.
DO NOT SET TRUSSES USING THIS LAYOUT
USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 Oleander Avenue
Fort Pierce, Florida 34982-6423
800-551-5932
Fort Pierce 772-465-2012 Fax 772-465-8711
Vero Beach 772569-2012 Stuart 772-2863302
Web Site: CHAMBERSTRUSS.COM
Frnail• MAII 1ACHAMRFRSTRIIRS.COM
92.0/93.2 MITEK 4.2
DESIGN CRITERIA
County
SAINT LUCIE
Building Department
City of PORT ST LUCIE
Wind Design Criteria
ASCE 7-2010
Wind Design Method
Main Wind Force Resisting
Roofing Material
Shingle or Shake
Loading in PSF
Roof R.D.L.
Floor
Top Chord Live
20
40
Top Chord Dead
7 4.2
7
Bottom Chord Live
10 Non -Concurrent
0
Bottom Chord Dead
10 3
5
TOTAL Load
37 7.2
52
Duration Factor
1.25
1
Wind Speed
165mph
Top Chord C.B.
Sheeting by builder.
Bottom Chord C.B.
Sheeting by builder.
Highest Mean Height
22"Aw
Building Type
ENCLOSED
Building Category
II:Non Restrictive
Exposure Category
C
Barrier Island
No
Conforms to FBC 2010
R.D.L.=Restraining Dead Load C.B.=Continuous Bracina
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Chambers Truss Inc. Drawing Name: 71909
Scale: 3/16 = 1'
77 total trusses, 15 different trusses.
MI 4: RAC ACAD: RAC Reviewed By:
Date: 05/29/14
FOR
MAYHEW
to
DESCRIPTION:
MAYHEW DETACHED GARAGE
PAGE 1 Of 1 CUSTOMER INITIALS EACH PAGE
PAUL WELCH INC.
MECH-ELECT-CIVIL ENG
1994 BILTMORE ST. a 114
PAUL WELCH P F A RE34984
G NO 29945
4 t V I t—w 0M L_ j
15 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT
71909
JUL 032014
® Lumber design values are in accordance with ANSI/.TPI 1 section 6.3
These truss designs rely on lumber values established by others.
MiTek®
RE: 71909 - MiTek USA, Inc.
Site Information: 6904 Parke East Blvd.
f�"-Customer Info: Ken Mayhew Project Name: Detached Garage Model: Tampa, FL33610-4115
,Lot/Block: Subdivision:
Address: unknown
City: Port St. Lucie State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City: State:
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2010/TP12007 Design Program: MiTek 20/20 7.3
Wind Code: ASCE 7-10 [All HeighIl Wind Speed: 165 mph
Roof Load: 37.0 psf Floor Load: 52.0 psf
This package includes 15 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No.
I Seal#
Truss Name
Date
1
IT6335469
I A
5/30/014
12
I T6335470
I C
1 5/30/014
13
I T6335471
I D
1 5/30/014
14
I T6335472
I DA
1 5/30/014
15
I T6335473
I FLA
1 5/30/014 1
16
I T6335474
I FLAA
1 5/30/014
17
I T6335475
J FLB
1 5/30/014
18
I T6335476
I G EA
1 5/30/014
19
I T6335477
I GFA
1 5/30/0141
110
I T6335478
I GFB
1 5/30/014
111
I T6335479
I GFC
1 5/30/014
112
I T6335480
I GRA
1 5/30/014
113
I T6335481
I GRD
1 5/30/014
14
IT6335482
I SG D
5/30/014
115
I T6335483
I V4 1
5/30/014
The truss drawing(s) referenced above have been prepared by MiTek
Industries, Inc. under my direct supervision based on the parameters
. provided by Chambers Truss.
Truss Design Engineer's Name: Velez, Joaquin
My license renewal date for the state of Florida is February 28, 2015.
IMPORTANT NOTE: Truss Engineer's responsibility is solely for
design of individual trusses based upon design parameters shown
on referenced truss drawings. Parameters have not been verified
as appropriate for any use. Any location identification specified is
for file reference only and has not been used in preparing design.
Suitability of truss designs for any particular building is the
responsibility of the building designer, not the Truss Engineer,
per ANSI/TPI-1, Chapter 2.
`��.Op,QV I N
:�� S••�GENSF•'���:
8182
=-o * C=
3 STATE OF :�/JJ
00
FL Cert. 6634
May 30,2014
Velez, Joaquin 1 of 1
Job
I russ
Truss Type
aty
Ply
T6335469
71909
A
COMMON
10
1
Job Reference (optional)
unamDers I russ Inc., von coerce r•I. 349a'L 7.350 a Sep 27 2012 MITek IndusMes, Inc. Fri May 30 09:53:23 2014 Page 1
ID: KFrZRBiAGM3E5QG?D_rdQSzltLw-WQzf hxRKb3JOOFaz? Rkgw11 hQ2ft?BMB F?4RTpzBMQg
1-0 0 3-0.12 6-1-8 7-1-8
1-0-0 3-0.12 3-0-12 1-0-0
LOADING (psf)
SPACING
2-0-0
CSI
TCLL
20.0
Plates Increase
1.25
TC 0.05
TCDL
7.0
Lumber Increase
1.25
BC 0.14
BCLL
0.0 '
Rep Stress Incr
YES
WB 0.04
BCDL
10.0
Code FBC2010/rP12007
(Matrix-M)
LUMBER
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP No.3
WEBS 2x4SPNo.3
REACTIONS (lb/size) 2=240/0-1-8 (min. 0-1-8), 4=240/0-1-8 (min. 0-1-8)
Max Horz2=-93(LC 6)
Max Uplift2— 232(LC 8), 4=-232(LC 8)
Max Grav2=281(LC 2), 4=281(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BOT CHORD 2-6=-95/271
Scale = 1:15.8
4x4 =
3x4 =
DEFL in (loc) Vdefl Ud PLATES GRIP
Vert(LL) -0.00 6 >999 360 MT20 244/190
Vert(TL) -0.01 6-12 >999 240
Horz(fL) 0.00 4 n/a n/a
Weight: 25 lb FT = 0%
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc p6dins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuft=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=22ft; B=45ft; L=50ft; eave=6ft; Cat. II;
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2, 4.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 232 lb uplift at joint 2 and 232 lb uplift at
joint 4.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model Was used in the analysis and design of this truss.
LOAD CASE(S) Standard
�`�,,,Qv I N
%C' 1 VF °°11i
.� OP.•
i
N 68182
T F : 1U •
%.
FL Cert. 6634
May 30,2014
© WARWKG - Verify design patmneters and READ NOTES ON THIS AND INCLUDED W7EKREFERENCE PAGE MI-7473 BEFORE USE.
Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction Is the responsibillity, of the
MTek'
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/rPll Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Taus Plate Institute, 781 N. Lee Sheet, Suite 312, Alexandria VA 22314.
its authem Pine (SP} lumber is specif ed, the design values are those effective O6/01/2013 by ALSC
Tampa, FL 33610.4115
Job
Truss
Truss Type
Qty
ply
T6335470
71909
C
MONO TRUSS
17
1
Job Reference (optional)
Chambers Truss Inc., Fort Pierce FI. 34982 7.350 s Sep 27 2012 MiTek Industries, Inc. Fri May 30 09:53:24 2014 Page 1
ID:KFrZRBiAGM3E5QG?D—rdQSzltLw-_d W 1 vHSyMM RseP99Y8G3TEapf R_kdLKTfq_?FzBMQf
2-9-0 TV
2-9.0 1
Scale: V=V
3x5 II
3x4 =
Provide bearing connection(s) to resist
horizontal reaction(s) shown. 3 2x3 II
zs0
- T-
LOADING (psf)
SPACING
2-0-0
CSI
DEFL
in (loc)
Vdefl
Ud
PLATES GRIP
TOLL 20.0
Plates Increase
1.25
TO 0.21
Vert(LL)
-0.00 6
n/r
180
MT20 244/190
TCDL 7.0
Lumber Increase
1.25
BC 0.21
Vert(TL)
-0.01 6
n/r
90
BOLL 0.0 '
Rep Stress Incr
YES
WB 0.06
Horz(rL)
0.00
n/a
n/a
BCDL 10.0
Code FBC2010/rP12007
(Matrix-M)
Weight: 11 lb FT = 0%
LUMBER
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS (lb/size) 3=179/Mechanical, 2=0/Mechanical
Max Horz3=288(LC 8), 2=-199(LC 8)
Max Uplift3=-254(LC 8)
Max Grav3=207(LC 2)
FORCES (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 1-2= 306/272
BOT CHORD 1-3=-224/324
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-10-8 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES
1) Wind: ASCE 7-10; Vuft=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=22ft; B=45ft; L=50ft; eave=6ft; Cat. II;
Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 254 lb uplift at joint 3.
6) "Semi -rigid pftchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
G•ENSF.��'���
i
N 68182
�•
T OF
FL Cert. 6634
May 30,2014
© WARMNG - Verify design parmneters and RFAD NOTES ON THIS AND INCLUDED ivBTEK REFERENCE PAGE b1T1-7473 BEFORE USE.
Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and Is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer -not truss designer. Bracing shown
is forlateral support of individual web members only. Additional temporary bracing to insurestability during construction isthe responsibilllty of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
M iTek•
fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 781 N. Lee Sheet Suite 312, Alexandria, VA 22314.
If southem tine (sP) lumber is specified, the design values are those effective 06/01/2013 byALSC
Tampa, FL 33610-4i 15
Job
Truss
Truss Type
yply
T6335471
71909
D
SPECIAL
9
1
Job Reference (optional)
puma , r m , rrnr Waite n. awaaz /.3bv S Jep z/ zulz MI I eK Inauslnes, Inc. Fn May 3U U9:W:24 ZU14 Page 1
I D:KFrZRBiAG M3E5QG?D_rdQ5zltLw-_dW 1 vHSyMMRseP99Y8G3TEamwRv_kPAKTfq_?FzBMOf
2 0 0 6.11-13 13-11-9 20.11-13 28-0.0 30-0-0
6-11-13 ' 6-11-13 7-0-3 7-0.3 2�-0-0
Scale = 1:54.4
6.00 rl2
4x6 i 3.00112
v
I�
0
O
19
CO
3x6
i 6-11-13 i 14-3-8 20-11-13 28.0.0
6-11-13 7-3-11 6-8-5 7-0.3
LOADING (psf)
SPACING
2-0-0
CSI
DEFL
in (loc)
Vdefl
Ud
PLATES GRIP
TCLL 20.0
Plates Increase
1.25
TC 0.45
Vert(LL)
0.39 11-12
>859
360
MT20 244/190
TCDL 7.0
Lumber Increase
1.25
BC 0.53
Vert(TL)
-0.64 11-12
>521
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.90
Horz(TL)
0.26 8
n/a
n/a
BCDL 10.0
Code FBC2010/TP12007
(Matrix-M)
Weight: 124 lb FT = 0%
LUMBER
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS (lb/size) 2=974/0-3-8 (min. 0-1-8), 8=994/0-3-8 (min. 0-1-8)
Max Horz2=263(LC 8)
Max Upl-Ift2=-824(LC 8), 8=-850(LC 8)
Max Grav2=1133(LC 2), 8=1155(LC 2)
BRACING
TOP CHORD
Structural wood sheathing directly applied or 3-10-12 oc puriins.
BOT CHORD
Rigid ceiling directly applied or 5-2-1 oc bracing.
WEBS
1 Row at midpt 3-11
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
FORCES (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3295/2090, 3-4=-2251/1412, 4-5=-2167/1432, 5-6=-2101/1425, 6-7=-2147/1412,
7-8=-3027/1933
BOT CHORD 2-12= 1968/3144, 11-12=-1976/3151, 10-11=-1760/2898, 8-10= 1760/2898
WEBS 3-12=0/275, 3-11= 1153/802, 5-11=-622/1111, 7-11=-954/617
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuh=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=22ft; 8=45ft; L=50ft; eave=6ft; Cat. II
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4y ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
Td between the bottom chord and any other members.
5) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
6) ,Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 824 lb uplift at joint 2 and 850 lb uplift at
joint 8.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model Was used in the analysis and design of this truss.
LOAD CASE(S) Standard
♦♦�`%0C,U I N "VF
♦''ol
.' \ G•E N S'-.
i
N 1
68182
� 7� • XT�'F .W
FL Cert. 6634
May 30,2014
® WARNING - Verify design Parametem and READ NOTES ON THIS AND INCLUDED WIEKREPERENCE PAGE mn1.7473 BEFORE USE,
Design valid for use only with MTek connectors. This design is based only upon parameters shown, and Is for an individual building component.
Ed'
Applicability of design parameters and proper incorporation of component is responsibility of building designer -not taus designer. Bracing shown
is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
MiTek'
fabricailon, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 781 N. Lee Street Suite 312. Alexandria, VA 22314.
Ifs authem Pine (SP) lumber is specified, the design values are these effective 06/0112013 by ALSC
Tama, FL 33610-4115
P
Job
Truss
Truss TypeCity—
1
T6335472
71909
DA
SPECIAL
4
1
Job Reference (optional)
�namoem , russ inc., ron r,erce r,. 34vtsx 7.350 s Sep 27 2012 MITek Industries, Inc. Fn May 30 09:53:25 2014 Page 1
ID: KFrZRBiAGM3E5QG7D_rd05zltLw-Sp4P6dSa7gZIGZkL6snIOS7z9rIMTrCUiJZYXhzBMQe
4-2-7 11-2-10 18-2-13 20.2-13
4-2-7 7-0-3 7-0-3 2-0 0
6.00 12
5xx
2x3 11
3.00 12
4x5 !�- 3.00112
LOADING (psf)
SPACING
2-0-0
CSI
DEFL
in
(loc)
Vdefl
Ud
TCLL 20.0
Plates Increase
1.25
TC 0.29
Vert(LL)
0.11
7
>999
360
TCDL 7.0
Lumber Increase
1.25
BC 0.33
Vert(TL)
-0.20
7-8
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.98
Horz(rL)
0.05
5
n/a
n/a
BCDL 10.0
Code FBC2010/TPI2007
(Matrix-M)
LUMBER BRACING
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3 BOT CHORD
REACTIONS (lb/size) 9=562/Mechanical, 5=683/0-3-8 (min. 0-1-8)
Max Horz9=-138(LC 8)
Max Uplift9=-427(LC 8), 5=-604(LC 8)
Max Grav9=650(LC 2), 5=797(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-744/455, 2-3=-664/441, 3-4=-714/428, 4-5=-1721/1038, 1-9= 615/406
BOT CHORD 7-8=-896/1636, 5-7=-896/1636
WEBS 2-8= 9/268, 4-8=-1037/713, 4-7=0/274, 1-8=-351/648
Scale = 1:37.0
PLATES GRIP
MT20 244/190
Weight: 86 lb FT = 0%
Structural wood sheathing directly applied or 5-5-2 oc purlins, except
end verticals.
Rigid ceiling directly applied or 7-9-2 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuft=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=22ft; B--45ft; L=50ft; eave=6ft; Cat. II;
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
*fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 427 lb uplift at joint 9 and 604 lb uplift at
joint 5.
7) :Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
,011111Mill 'r
.�` Qv _1 N V.
♦♦♦ QP;
•GENS4'
i
N 68182
7tC
9 T F : !L
C?
fill
III
FL Cert. 6634
May 30,2014
Q WARNING - Verify design pim ameteis and READ NOTES ONTHIS AND INCLUDED M EKREFERENCE PAGE b7II-7473 BEFORE USE.
Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer -not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability, during construction is the responsibillity of the
erector. Additional bracing the is the the building designer. For
MiTek°
permanent of overall structure responsibility of general guidance regarding
fabrication quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 781 N. Lee Street Suite 312 Alexandria, VA 22314.
Ifsauthem Pine (SP) lumberis specified, the design values are those effective Ofi/01,/2013 byALSC
Tampa, FL 33610-4f 15
Job
Truss
Truss Type
city
ply
T6335473
71909
FLA
FLOOR
2
1
Job Reference (optional)
•__ �-� _�_ • ��_�� r.00u s aep zr Zu ie mu eK mcumnes, inc. rn may su as:aa:Zn Zuiq rage i
ID: KFrZRBiAGM3E5QG?D_rdQ5zltLw-w?enKzTDu_hatjJYgZIXYff4uFU ECL?dxzJ537zBMQd
4-7-8 8-9-3 8- 12 13-0 0 14-0-0 15-0-0 19-2-4 23-4-8 28-D-0
4-7-8 4.1-11 0 -9 4-2-4 1.0-0 1-0-0 4-2-4 4-2-4 4-7-8
14x12 =
2x3 II 3x10 = 2x3 11 2x3 II 3x8 = 3x10 =
2 3 4 5 6 7
Scale: 1/4'=1'
2x3 II 4x12 =
8 9
m R_
rn
N
18 17 16 15 14 13 12 11 10
3x4 = 6x10 = 2x3 11 5x8 MT18HS WB = 3x5 = 2x3 11 6x10 = 3x4 =
3x5 =
LOADING (psi)
TCLL 40.0
TCDL 7.0
BCLL 0.0
BCDL 5.0
SPACING 2-0-0
Plates Increase 1.00
Lumber Increase 1.00
Rep Stress Incr YES
Code FBC2010/TPI2007
CSI
TC 0.55
BC 0.99
WB 0.82
(Matrix-M)
DEFL in (loc) Vdefl Ud
Vert(LL) -0.62 13-14 >540 480
Vert(TL) -0.89 13-14 >372 360
Horz(rL) 0.14 10 n/a n/a
PLATES GRIP
MT20 244/190
MT18HS 244/190
Weight: 142 lb FT = 0%
LUMBER
BRACING
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-6-11 oc p6dins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3 *Except*
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
1-17,9-11: 2x4 SP M 30
2-2-0 oc bracing: 13-14.
MiTek recommends that Stabilizers and required cross bracing
Lie installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 18=1441/0-3-8 (min. 0-1-11), 10=1441/0-3-8 (min. 0-1-11)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-18= 1403/0, 1-2= 3076/0, 2-3=-3076/0, 3-4=-5540/0, 4-5=-5540/0,
5-6=-5540/01
6-7=-5540/0, 7-8= 3076/0, 8-9=-3076/0, 9-10= 1403/0
BOT CHORD 16-17=0/4828, 15-16=0/4828, 14-15=0/4828, 13-14=0/5540, 12-13=0/4828, 11-12=0/4828
WEBS 1-17=0/3217, 2-17=-416/0, 3-17= 1906/0, 3-14=-27/1186, 7-13= 27/1186, 7-11=-1906/0,
8-11=-416/0, 9-11=0/3217, 4-14=-277/0, 5-13=-277/0
NOTES
1) Unbalanced floor live loads have been considered for this design.
2) All plates are MT20 plates unless otherwise indicated.
3) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
4) Required 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be
attached to walls at their outer ends or restrained by other means.
LOAD CASE(S) Standard
QV l N00
N 68182
53 aT F /U •
O'• w:
fill III
FL Cent. 6634
May 30,2014
Q WARM* - Verify design parameters and READ NOTES ON THIS AAID INCLUDED 11177EKREPERENCE PAGE 1717-7473 BEPORE USE.
Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an Individual budding component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer -not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the
erector. Additional bracing the Is the the
MiTek"
permanent of overall structure responsibility of building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/rPll (duality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safey Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
itS�uthern Pine (SP) lumber is specified, the design values are those effective 06101/2013 by ALSC
Tampa, FL 33610-4115
Job
Truss
Truss Type
City
ply
T6335474
71909
FLAA
GABLE
2
1
Job Reference (optional)
`����^�`•��� �"„ ^`••, . �.. �.c.oc .-.• •�+�o� r.JDa 5 —P Zr 4V 14 mil I eK maus[nes, mc. rn may JU uv;mi:eo zul4 rage l
I D: KFrZRB iA G M3E5Q G?D_rdQ5zltLw-w?enKzTD u_hatjJ YgZ IXYftCIFj eCX2dxzJ537zBMQd
28-0-0
28-0-0
Scale= 1:46.8
5x6 =
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
m q
N
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
5x6 =
date clltsets (X,Y): 19:D-3-D,0-3-01,124:0-3-0,0-3-01
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in
(loc) Vdefl Ud
PLATES GRIP
TCLL 40.0
Plates Increase 1.00
TC 0.04
Vert(LL) n/a
n/a 999
MT20 244/190
TCDL 7.0
Lumber Increase 1.00
BC 0.01
Vert(TL) n/a
n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.05
Horz(TL) 0.00
16 n/a n/a
BCDL 5.0
Code FBC2010/TP12007
(Matrix)
Weight: 116 lb FT = 0%
LUMBER BRACING
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc pudins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3 BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 28-0-0.
(lb) - Max Grav All reactions 250 lb or less at joint(s) 30, 16, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20,
19, 18, 17
FORCES (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) All plates are 2x3 MT20 unless otherwise indicated.
2) Gable requires continuous bottom chord bearing.
3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4) Gable studs spaced at 2-0-0 oc.
5) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means. ��,11 1111111
�I111,I
LOAD CASE(S) Standard wOP,QU I N
N( 68182
T OF�•
i��',ss' •.N ALES ;C� �.
/11111111
FL Cert. 6634
May 30,2014
© WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MIT EKREFERENCE PAGE b?II-7473 BEPORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown. and Is for an individual building component,
Not
Applicability of design parameters and proper Incorporation of component is responsibility of building designer -not truss designer. Bracing shown
is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during conshuction is the responsibillity of the
erector. Additional bracing the is the the building designer.
M iTek'
permanent of overall structure responsibility of For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/rPll Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Parkeass Blv
Safety Information available from Taus Plate Institute, 781 N. Lee Sheet, Suite 312, Alexandria, VA 22374.
It Southern pine (SP) lumber is specified, the design values are those effective 06/01/2013 by ALSC
.
Tampa, 3
Job
Truss
Truss Type
yly
T6335475
71909
FLB
FLOOR
15
1
Job Reference (optional)
s truss inc., Fort Pierce Fi. 349BZ 7.350 s Sep 27 2012 MiTek Industries, Inc. Fri May 30 09:53:27 2014 Page 1
ID: KFrZRBiAGM3E5QG?D_rdQ5zitLW-OBC9XJUrf HpRVitkEHpm5tCFbfgbmbn9d2ecazBMQc
4-7-8 8-9-12 13 0.0 14-0-015-0-0 19-3 7 23 6-13 28-0-0
4-7-8 4-2-4 4-2.4 1-0-0 1-0-0 4-3-7 4-3 6 4-5-3
6x8 =
2x3 11
3x10 =
2x3 11
2x3 11 3x6 = 3x10 =
4 5 6 7
2x3 11
Scale = 1:49.2
5x8 =
18 17 16 15 14 13 12 11 10
2x3 II
6x10 =
Ol
5x8 WB= 3x5 = 2x3 II
3x5 =
6x10 =
LOADING (psf)
TCLL 40.0
TCDL 7.0
BCLL 0.0
BCDL 5.0
SPACING 2-0-0
Plates Increase 1.00
Lumber Increase 1.00
Rep Stress Incr YES
Code FBC20101TP12007
CSI
TC 0.55
BC 0.97
WB 0.86
(Matrix-M)
DEFL in (loc) Vdefl Ud
Vert(LL) -0.59 13-14 >557 480
Vert(TL) -0.86 13-14 >384 360
Horz(rL) -0.02 10 n/a n/a
PLATES GRIP
MT20 244/196
Weight: 140 lb FT = 0%
LUMBER
BRACING
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-7-0 oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3 *Except*
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
1-17,9-11: 2x4 SP M 30
2-2-0 oc bracing: 13-14.
OTHERS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 10=1426/0-3-8 (min. 0-1-11), 1=1426/0-3-8 (min. 0-1-11)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2898/0, 2-3=-2898/0, 3-4=-5426/014-5= 5426/0, 5-6=-5426/0,
6-7=-5426/0,
7-8= 2939/0, 8-9=-2939/0, 9-10=-1391/0
BOT CHORD 16-17=0/4662, 15-16=0/4662, 14-15=0/4662, 13-14=0/5426, 12-13=0/4732, 11-12=0/4732
WEBS 1-17=0/3152, 2-17=-439/013-17=-1919/0, 3-14=0/1214, 7-13= 33/1165, 7-11=-1945/0,
8-11=-420/0, 9-11=0/3117, 4-14=-286/0, 5-13= 272/0
NOTES
1) Unbalanced floor live loads have been considered for this design.
2) The solid section of the plate is required to be placed over the splice line at joint(s) 15.
3) Plate(s) at joint(s) 15 checked for a plus or minus 3 degree rotation about its center. %0 001 N
4) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. o,% p.Q• ...... F� °i°
5) Required 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be �� O G E • • • • ��
-attached to walls at their outer ends or restrained by other means. ee .•• �,� S�`•• ? �i
6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. i
N 68182
LOAD CASE(S) Standard
'�. T OF
001
�N
nnilll►
FL Cert. 6634
May 30,2014
0 WARWATG - Verify design parmneters and READ N07ES ONTHIS AND INCLUDED 1U7EKJZEFERENCE PAGE bB1-7473 BEFORE USE.
"
Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an individual bolding component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibillity of the
Additional bracing the is the
MiTek*
erector. permanent of overall structure responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/IPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
Ifs outhern Pine (SP) lumber is specified, the design values are timse effective 06/01/2013 by ALSO
Tama FL 33610-4115
P
Job
Truss
Truss Type
City
Fly
T6335476
71909
GEA
COMMON
2
1
Job Reference (optional)
unamoers , ruse inc., Fon Fierce N. U4aar 7.350 is Sep 27 2012 MTek Indusines, Inc. Fri May 30 09:53:28 2014 Page 1
ID:KFrZRBiAGM3E5QG?D_rdQ5zitLW-sOmXkfVTPbxl71 Swn_K?d4lY93M2gRbwOHoCBOzBMQb
1-0 0 3-0.12 6-1-8
1-0.0 3-0.12 3-0-12
4x4 =
3x4 =
Scale = 1:15.8
LOADING (psf)
SPACING
2-0-0
CSI
DEFL in
(loc) Vdefl Ud
PLATES GRIP
TCLL 20.0
Plates Increase
1.25
TC 0.05
Vert(LL) -0.00
6 >999 360
MT20 244/190
TCDL 7.0
Lumber Increase
1.25
BC 0.14
Vert(TL) -0.01
6-12 >999 240
BCLL 0.0 "
Rep Stress Incr
YES
WB 0.04
Horz(fL) 0.00
4 n/a n/a
BCDL 10.0
Code FBC2010/TPI2007
(Matrix-M)
Weight: 25 lb FT = 0
LUMBER
BRACING
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation auide.
REACTIONS (lb/size) 2=240/0-1-8 (min. 0-1-8), 4=240/0-1-8 (min. 0-1-8)
Max Horz2=-93(LC 6)
Max Upl'Ift2=-232(LC 8), 4= 232(LC 8)
Max Grav2=281(LC 2), 4=281(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BOT CHORD 2-6=-95/271
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=22ft; B=45ft; L=50ft; eave=6ft; Cat. II
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2, 4.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 232 lb uplift at joint 2 and 232 lb uplift at
joint 4.
7)+'Semi-rigid pitchbreaks including heels' Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
N 68182
T 'O F
%
� N A1.E�C? �
11JI11 11
FL Cert. 6634
May 30,2014
Q WARNING - Verify design parameters and READ NOTES ON7711S AND INCL UDED MIT PSREPEREINCE PAGE 161-7473 BEFORE USE.
Design valid for use only with MTek connectors. This design Is based only upon parameters shown and Is for an Individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
�a
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction Is the responsibility of the
Additional bracing the is the
M iTek'
erector. permanent of overall structure responsibility of the building designer. For general guidance regarding
fabrication quality control, storage, delivery, erection and bracing, consult ANSI1rP11 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safefy Informal n available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
If Southern Pine (SP) lumber is specified, the design values;fre those effective 0�6/01/2019 by ALSO
Tama FL 33610-4i 15
P
Job
Truss
Truss Type
Qty
Ply
T6335477
71909
GFA
FLOOR
1
2
Job Reference (optional)
unamoers I russ Inc., I -on Pierce r-I. 34982 7.350 s Sep 27 2012 MiTek Industries, Inc. Fri May 30 09:53:28 2014 Page 1
ID:KFrZRBiAGM3E50G?D_fdQ5ZItLW-sOmXkfVTPbxl71 Swn_K?d41JM3H4glJwOHoC80zBMQb
i 3-2-7 6-6-9 9-9-0
3-2-7 3.4-3 3-2-7
Scale = 1:18.6
3x4 11 3x10 = 30 11
1 7x8 = 9 2 10 3 11 4
5x8 MT18HS I I
5x8 MT18HS=
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in
(loc) Vdefl L/d
PLATES
GRIP
TCLL 40.0
Plates Increase 1.00
TC 1.00
Vert(LL) -0.03
6-7 >999 480
MT20
244/190
TCDL 7.0
Lumber Increase 1.00
BC 0.46
Vert(TL) -0.08
6-7 >999 360
MT18HS
244/190
BCLL 0.0
Rep Stress Incr NO
WB 0.64
Horz(TL) 0.02
5 n/a n/a
BCDL 5.0
Code FBC2010/TP12007
(Matrix-M)
Weight: 130 lb
FT = 0%
LUMBER
BRACING
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 1-11-14 oc pudins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3 "Except'
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
1-7: 2x4 SP M 30
REACTIONS (lb/size) 8=5322/0-4-8 (min. 0-3-2), 5=6687/0-4-8 (min. 0-3-15)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-8=-5243/0, 1-9= 5098/0, 2-9= 5098/0, 2-10=-5098/0, 3-10=-5098/0, 4-5=-3520/0
BOT CHORD 6-7=0/4003, 5-6=0/4003
WEBS 1-7=0/6334, 2-7=-4771/0, 3-7=0/1351, 3-5= 5036/0
NOTES
1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x4 -1 row at 0-9-0 oc.
Webs connected as follows: 2x4 -1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) All plates are MT20 plates unless otherwise indicated.
4) "Semi -rigid pitchbreaks including heels" Member end fairy model was used in the analysis and design of this truss.
5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
LOAD CASE(S) Standard
1) Floor: Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (plf)
Vert: 1-4=-72, 5-8=-10
Concentrated Loads (lb)
Vert: 4=-3198 2=-3198 9=-2175 10= 133211=-1332
I N'
-EV F< �� ♦♦
i
NS�.F� a,
i
N 68182
*
r �
T F
.00
FL Cert. 6634
May 30,2014
A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED 1UT KREFERENCE PAGE WI.7473 BEFORE USE.
�
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
�'
is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the
Additional bracing the is the
MiTek`
erector. permanent of overall structure responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult ANSIAPll Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information ovalable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria VA 22314.
if Southern Pine [SP) lumber is specified, the design values are those effective 06/03/2013 by ALSC
Tampa, FL 33610.4t 15
Job
Truss
Truss Typ
Qty
Ply
T6335478
71909
GFB
FLOOR
1
2
Job Reference (optional)
unamoers i russ inc., Ton Tierce FI. 349a2 7.350 s Sep 27 2012 MiTek Industries, Inc. Fri May 30 09:53:29 2014 Page 1
ID:KFrZRBiAGM3E5QG?D_rdQ5zltLw-KaKwytV5Au39kA17LhrEAIHY PSct Pi F4dxxlgSzBMQa
3.2-7 6.6-9 9-9-0
3-2-7 3-4-3 3-2-7
Scale = 1:18.6
3x6 11 4x8 = US 11
1 10xio = 9 2 10 3 11 12 4
5x8 MT18HS II 5x8 MT18HS=
'
--- - -- 3-2-7
3-4-3
13-2-7
LOADING (psf)
SPACING
2-0-0
CSI
DEFL
in
(loc)
Vdefl
Ud
PLATES
GRIP
TCLL 40:0
Plates Increase
1.00
TC 0.72
Vert(LL)
-0.05
6-7
>999
480
MT20
244/196
TCDL 7.0
Lumber Increase
1.00
BC 0.55
Vert(TL)
-0.08
6-7
>999
360
MT18HS
244/190
BCLL 0.0
Rep Stress Incr
NO
W B 0.79
Horz(TL)
0.02
5
n/a
n/a
BCDL 5.0
Code FBC2010/TPI2007
(Matrix-M)
Weight: 142 lb
FT = 0%
LUMBER BRACING
TOP CHORD 2x8 SP 240OF 2.0E TOP CHORD
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3 *Except* BOT CHORD
1-7: 2x4 SP M 30
REACTIONS (lb/size) 8=5520/0-4-8 (min. 0-3-4), 5=5814/0-4-8 (min. 0-3-7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-8=-5463/0, 1-9=-5028/0, 2-9=-5028/0, 2-10=-5028/0, 3-10=-5028/0, 4-5= 1938/0
BOT CHORD 6-7=0/505115-6=0/5051
WEBS 1-7=0/6229, 2-7=-3775/0, 3-5=-6258/0
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES
1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x4 -1 row at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) All plates are MT20 plates unless otherwise indicated.
4) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
LOAD CASE(S) Standard
1) Floor: Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (plf)
Vert: 1-4=-72, 5-8=-10
Concentrated Loads (lb)
Vert: 2=-2112 9=-2112 10=-2112 11=-2112 12=-2112
.%J ? J001 N
N 68182
T OF �/•'
FL Cert. 6634
May 30,2014
Q WARNING - Verify design parameters and READ NOTES ONTHIS ANI) INCLUDED WTEKREFERENCE PAGE AYU-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters showa and is for an individual building component.
Wit
Applicability of design parameters and proper incorporation of component Is responsibility of building designer -not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the
erector. Additional bracing the Is the the building designer. For
MiTek
permanent of overall structure responsibility of general guidance regarding
fabrication quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and SCSI Building Component
safety Information available from Truss Plate Institute, 781 N. Lee Street Suite 312, Alexandria, VA 22314.
If Southern Pine (SP} lumber is specified, the design values are those effective OS/01/'2013 by ALSC
6904 Parke East Blvd.
Tampa, FL 33610-4115
Job
Truss
Truss Type
Qty
y
T6335479
71909
GFC
FLOOR
1
2
Job Reference o tional
unamuers I russ Inc., I-ort Pierce 1-1. 349B2 7.350 s Sep 27 2012 MiTek Industries, Inc. Fri May 30 09:53:29 2014 Page 1
ID:KFrZRBiAGM3E5QG7D_rdQ5zltLw-KaKW.V5Au39kA17LhrEA1HW1SchPi 4dxXIgSzBMQa
r 3-2-7 , 6.6.9 9-9-0
3-2-7 3-4-3 3-2-7
Scale= 1:18.6
2x3 11 4x10 = 3x4 11
1 7x8 =
5x8 MT18HS II V^ V^V 5x8 MT18HS=
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in
(loc) Vdefl Ud
PLATES
GRIP
TCLL 40.0
Plates Increase 1.00
TC 0.87
Vert(LL) -0.03
6-7 >999 480
MT20
244/190
TCDL 7.0
Lumber Increase 1.00
BC 0.56
Vert(TL) -0.09
6-7 >999 360
MT18HS
244/190
BCLL 0.0
Rep Stress Incr NO
WB 0.80
Horz(rL) 0.03
5 n/a n/a
BCDL 5.0
Code FBC2010frP12007
(Matrix-M)
Weight: 130 lb
FT = 0%
LUMBER
BRACING
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3 `Except'
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
1-7: 2x4 SP M 30
REACTIONS (lb/size) 8=6623/0-4-8 (min. 0-3-15), 5=5386/0-4-8 (min. 0-3-3)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-8=-6576/0, 1-9=-3946/0, 2-9=-3946/0, 2-10= 3946/0, 3-10=-3946/0, 4-5=-1371/0
BOT CHORD 6-7=0/5100, 5-6=0/5100
WEBS 1-7=0/4955, 2-7=-2220/0, 3-7= 1423/0, 3-5=-6346/0
NOTES
1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 -1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x4 -1 row at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) All plates are MT20 plates unless otherwise indicated. ,+ 111/1111 f /� ,'
4) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. �� LOIN VF �I
5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means. ,, OP`• • �� /,
WAD CASE(S) Standard
1) Floor: Lumber Increase=1.00, Plate Increase=1.00 N 68182
Uniform Loads (plf)
Vert: 1-4=-72, 5-8— 10
Concentrated Loads (lb)
Vert: 1= 3198 3=-3198 9=-1332 10=-1332 11� 2175
T F :•I(/
lo
,•,joss,, �� N A� E�C7 �.
111
FL Cert. 6634
May 30,2014
Q WARMNG - Verify design parameters and READ NOTES ONTXIS AND INCLUDED M IEKREPERENCE PAGE )61-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design parameters and proper incorporation of component Is responsibility of building designer -not truss designer. Bracing shown
is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the
Additional bracing the is the the building
MiTek"
erector. permanent of overall structure responsibility of designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/rPll Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
scmTampa,
m Pine (SP) lumber is specified, the design values am those effective 06/01/2013 by ALSC
FL 33610.4i 15
Job
Truss
Truss Type
Qty
ply
T6335480
71909
GRA
SPECIAL
4
1
Job Reference (optional)
chambers Truss Inc., Fort Pierce Ff. 34982 7.350 s Sep 27 2012 MiTek Industries, Inc. Fri May 30 09:53:30 2014 Page 1
ID:KFrZRBiAGM3E5QG?D_rdQ5zitLW-om ul9LWjxCBOMKcJVPNTjVgkZsww8AxDsbHJ DvzBMQZ
4-9-13 9-7-11 13-11-9 18-7-12 23-3-14 28 0 0 30-0 0
4-9-13 4-9-13 4-3.15 4-8-2 4-8-2 4.8-2 2-0-0
3.00112
3x10 II
5x6 i 3.00112
6.00 12
LOADING (psf)
SPACING
2-0-0
CSI
DEFL
in (loc)
Udefl
Ud
TCLL 20.0
Plates Increase
1.25
TC 0.69
Vert(LL)
0.45 12-13
>747
360
TCDL 7.0
Lumber Increase
1.25
BC 0.69
Vert(Q
-0.75 12-13
>447
240
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.76
Horz(FL)
0.31 8
n/a
n/a
BCDL 10.0
Code FBC2010frP12007
(Matrix-M)
LUMBER
BRACING
TOP CHORD 2x4 SP M 30 *Except'
TOP CHORD
1-3: 2x6 SP No.2
BOT CHORD 2x6 SP 240OF 2.0E 'Except'
BOT CHORD
8-12: 2x4 SP M 31
WEBS
WEBS 2x4 SP No.3 *Except*
1-14,2-13,4-12: 2x4 SP M 30
REACTIONS (Ib/size) 15=2157/0-3-8 (min. 0-2-0), 8=1454/0-3-8 (min. 0-1-8)
Max Horz15=-126(LC 8)
Max Upliftl5= 1451(LC 8), 8=-1087(LC 8)
Max Grav 15=2498(LC 2), 8=1690(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-15=-2459/1429, 1-19=-2942/1648, 19-20=-2942/1648, 2-20=-2942/1648,
2-21=-6282/3354, 21-22=-6277/3353, 22-23=-6273/3351, 3-23=-6269/3349,
3-4=-4299/2367, 4-5=-4212/2345, 5-6=-4769/2682, 6-7=-4784/2675, 7-8=-4865/2722
BOT CHORD 13-14=- 1 562/3025,12-13= 3385/6566, 11-12=-2447/4627, 10-11= 2534/4677,
8-10— 2534/4677
WEBS 1-14= 2062/3682, 2-14=-2795/1659, 2-13=-1912/3747, 3-13=-1682/1088,
3-12=-2683/1433, 4-12= 1400/2696, 5-12= 673/464
Scale = 1:54.5
PLATES GRIP
MT20 244/190
MT18HS 244/190
Weight: 168 lb FT = 0%
Structural wood sheathing directly applied or 2-4-6 oc pudins, except
end verticals.
Rigid ceiling directly applied or 4-9-15 oc bracing.
1 Row at midpt 1-15, 3-12
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES
1) Unbalanced roof live loads have been considered for this design:
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=22ft; B=45ft; L=50ft; eave=6ft; Cat. 11;
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) Bearing at joint(s) 15 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1451 lb uplift at joint 15 and 1087 lb uplift at
joint 8.
9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 266 lb down and 154 lb up at
2-0-12, 266 lb down and 154 lb up at 4-0-12, 266 lb down and 154 lb up at 6-0-12, and 266 lb down and 154 lb up at 8-0-12, and 266
lb down and 154 lb up at 9-4-0 on top chord, and 817 lb down and 285 lb up at 9-8-7 on bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
Continued on page 2
,oIIIIIII1r1I
a�®�� QU 1 N V�` I � ,
N 68182
?� • T F
,•���s`S; � N
1111111111001
FL Cert. 6634
Mav 30,2014
© WARNING- Verify design parameters and READ NOTES OK INIS AND INCLUDED rMEKREFERENCE PAGE br/1.7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design parameters and proper Incorporation of component Is responsibility of building designer -not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity, of the
erector. Additional bracing the is the the building designer. For
MiTek'
permanent of overall structure responsibility of general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/iPll Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
If Southern Pine (SP) lumber is specified, the design values are those effective O6/01/2013 by ALSC
Tampa, FL 33610.4i 15
Job
Truss
runs Type
City
ply
T6335480
71909
GRA
SPECIAL
4
1
Job Reference (optional)
ram,. r,o,w r,, eY�oc (.3cu a bep L/ zui z MI I eK Inausines, Inc. F5:6 n May 30 03:39 2014 Page 2
ID: KFrZRBiAGM3E5QG7D_rdQ5zltLw-omul9LWjxCBOMKcJvPNTjVgkZsww8AxDsbHJDvzBMQZ
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plo
Vert: 1-3=-44, 3-4=-44, 4-9=-44, 12-15=-20, 12-16=-20
Concentrated Loads (lb)
Vert: 13=-701(F) 19=-208 20=-208 21=-208 22= 208 23=-208
PQ' v IN�J#'�.
:o� ,� • �� G•E IV g�C•�c� �i��
N 68182
�-10 :rcz
O:• T O F ::44/11111111
FL Cert. 6634
May 30,2014
O WARMNG - Verify design parameters and READ NOTES ON THIS AND INCLUDED MWBKREFERENCE RAGE MI-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer -not truss designer. Bracing shown
is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the
erector. Additional bracing of the Is the the building designer. For
M iTek`
permanent overall structure responsibility of general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult ANSKI'll Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria VA 22314.
If Southem Pine (SP} lumber is specified, the design values ate those effective 06/O1j2013 by ALSO
6904 Parke East Blvd.
Tampa, FL 33610-4115
Job
Truss
russ ype
QtyPly
T6335481
71909
GRD
SPECIAL
2
1
Job Reference (optional)
_�_ �• �Y�o� i.aou s aep zi evi z mi i eK inausines, ine. rn may aU Ue:0U:31 Z014 rage i
ID:KFrZRBiAGM3E5QG7D_rdQ5zltLw-HzRgNhXL WJt_UBVT6uiFjjNl7GMktjUM4FOsILzBMQY
2-11-4 5-10-8
2-11-4 2-11-4
1 5x6 =
2x3 [I
2
5x6 =
3
3x4 11
LOADING (psf)
SPACING
2-0-0
CSI
DEFL
in
(loc)
Udefl
Ud
TCLL 20.0
Plates Increase
1.25
TC 0.14
Vert(LL)
-0.01
4-5
>999
360
TCDL 7.0
Lumber Increase
1.25
BC 0.27
Vert(TL)
-0.02
4-5
>999
240
BCLL 0.0
Rep Stresslncr
NO
WB 0.35
Horz(TL)
0.00
4
n/a
n/a
BCDL 10.0
Code FBC2010/TP12007
(Matrix-M)
LUMBER BRACING
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 BOT CHORD
REACTIONS (lb/size) 6=721/Mechanical, 4=721/Mechanical
Max Uplift6=-336(LC 4), 4=-337(LC 4)
Max Grav6=836(LC 2), 4=837(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-6=-674/29411-2=-700/270, 2-3=-700/270, 3-4=-674/294
WEBS 1-5— 358/927, 3-5=-358/927
Scale = 1:19.6
PLATES GRIP
MT20 244/190
Weight: 41 lb FT = 0%
Structural wood sheathing directly applied or 5-10-8 oc purlins, except
end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=22ft; B=45ft; L=50ft; eave=6ft; Cat. II;
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 336 lb uplift at joint 6 and 337 lb uplift at
joint 4.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 630 lb down and 218 lb up at
1-11-4, and 630 lb down and 218 lb up at 3-11-4 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-44, 4-6=-20
Concentrated Loads (lb)
Vert: 7=-542(B) 8=-542(6)
��eeee,Ql7 I N
�` OP: • '
N 68182
�'.. T OF :�1JJ�
off, .•� `OQ;,:\_,,�
�i�� SS • ... • • �C? Vie`
ri N p11 E eeee
FL Cert. 6634
May 30,2014
a WARWNG - Verify design parameters and READ NOTES ONTHIS AND INCLUDED IMUKREFERENCE PAGE b9fI-7473 BEPORE USE.
Design for MTek
valid use only with connectors. This design is based only upon parameters shown, and is for an individual building component.
of design parameters and proper incorporation of component is responsibility of building designer -not truss designer. Bracing shown
WitAppilcability
is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the resporzibillity of the
erector. Additional bracing the is the the building designer. For
M iTek•
permanent of overall structure responsibility of general guidance regarding
fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPll Quality Criteria, DSB-89 and BCSI Building Component
Safety Informalion available from Taus Plate Institute, 781 N. Lee Street Suite 312, Alexandria, VA 22314.
If Southern 4?ine fSP} lumber is specified, the design values are those effective 06/0112013 by ALSC
6904 Parke East Bivd.
Tampa, FL 33610-4115
o
Job
Tru
Truss
russ ype
Qty
ply
T6335482
GABLE
2
1
Job Reference (optional)
I
of
u.em , , rvu rwu n. 54wo< "bu s Sep 2t 2u12 MI I eK industries, Inc. Fn May 30 09:53:32 2014 Page 1
ID:KFrZRBiAGM3E5QG?D_rdQ5zltLw-19?2aOYzTpRkbemhOgPxowv8vgescl9WJvm PHnzBMQX
6-11-13 13.11-9 20.11-13 28-0-0 300-0 ,
6-11-13 6-11-13 ' 7-0.3 7-0-3 250-O
3x6
6.00 12
4x6 i 3.00112
Scale = 1:54.4
LOADING (psfl
TCLL 20.0
TCDL 7.0
BCLL 0.0 '
BCDL 10.0
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Incr YES
Code FBC2010/TPI2007
CSI
TC 0.45
BC 0.53
WB 0.90
(Matrix-M)
DEFL in (loc) Vdefl Ud
Vert(LL) 0.39 11-12 >859 360
Vert(TL) -0.64 11-12 >521 240
Horz(TL) 0.26 8 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 146 lb FT = 0%
LUMBER
BRACING
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-10-12 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 5-2-1 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row at midpt 3-11
OTHERS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 2=974/0-3-8 (min. 0-1-8), 8=994/0-3-8 (min. 0-1-8)
Max Horz2=263(LC 8)
Max Uplift2=-824(LC 8), 8=-850(LC 8)
Max Grav2=1133(LC 2), 8=1155(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3295/2090, 3-4=-2251/1412, 4-5=-2167/1432, 5-6=-2101/1425, 6-7=-2147/1412,
7-8=-3027/1933
BOT CHORD 2-12=-1968/3144, 11-12=-1976/3151, 10-11=-1760/2898, 8-10— 1760/2898
WEBS 3-12=0/275, 3-11=-1153/802, 5-11=-622/1111, 7-11=-954/617
NOTES
1) Unbalanced roof live loads have been considered for this design.
,IIv
111111 ,�I��
2) Wind: ASCE 7-10; Vuft=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=22ft; B=45ft; L=50ft; eave=6ft; Cat. II;
Exp
N
C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
��, p` ..... �4
• - *ENS' • • `� �I
Gable End Details as applicable, or consult qualified building designer as per ANSUTPI 1.
,e4 ,0 �.
�, 4'
4) All plates are 2x3 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for 10.0 bottom live
.•
n .'
N( 68182 10
•�
a psf chord load nonconcurrent with any other live loads.
7) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
"
fit between the bottom chord and any other members.
-10
8) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
�3 •� T F
of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 824 lb uplift at joint 2 and 850 lb uplift at
8.
.'
�i • •, �<` ��
10i� P •� \`�
joint
10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
�j� ss • • ��%
LOAD CASE(S) Standard
N
�sl� n 11111
FL Cert. 6634
May 30,2014
Q W®!WING - Verify design parameters and READ NOTES ONTEIS AND INCLUDED WfEK REFERENCE PAGE au1.7473 BEFORE USE.
Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an individual building component.
�
Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction is the responslUdlity of the
erector. Additional permanent bracing of the overall structure is the responsiblf y of the building designer. For general guidance regarding
MiTek"
fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/rPll Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Sheet Suite 312 Alexandria, VA 22314.
6904 Parke East BWd.
if Southern Pine (513) lumberis specified, the design values aie those effective 06/01/2013 by ALSC
Tampa, FL 33610-4115
o
russ
russ ype
ty
ply
T6335483
71909
V4
VALLEY
2
1
Job Reference (optional)
— In.., — C'i... I. .q—g
3x4
/.35U s 5eP Z1 2U1'L MI I eK Incustnes, Inc. Fn May 30 09:53:32 2014 Pagel
ID:KFrZRBiAGM3E5QG?D_rdQ5zltLw-19?2aOYzTpRkbemhOq PxowvDugklcFFWJvm PHnzBMQX
4-0-0
2-0-0
US =
2
3x4
LOADING (psf)
SPACING
2-0-0
CSI
DEFL
in (loc)
Vdefl
Ud
TCLL 20.0
Plates Increase
1.25
TC 0.06
Vert(LL)
n/a
n/a
999
TCDL 7.0
Lumber Increase
1.25
BC 0.15
Vert(TL)
n/a
n/a
999
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(rL)
0.00 3
n/a
n/a
BCDL 10.0
Code FBC2010lrP12007
(Matrix)
LUMBER
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS (Ib/size) 1=88/4-0-0 (min. 0-1-8), 3=88/4-0-0 (min. 0-1-8)
Max Horz1= 32(LC 6)
Max Upliftl=-66(LC 8), 3= 66(LC 8)
Max Grav 1=102(LC 2), 3=102(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
Scale= 1:7.8
PLATES GRIP
MT20 244/190
Weight: 11 lb FT = 0%
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=22ft; 13=45ft; L=50ft; eave=6ft; Cat. II;
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 66 lb uplift at joint 1 and 66 lb uplift at joint
3.
7) ';Semi -rigid pftchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
toll 11111®/I
QU IN
.•��C.E NSF•. �.:
N( 68182
T F �1U+
���'�SS •.N ALE�G ��
111111/11
FL Cert. 6634
May 30,2014
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED 1DDTEKREFERENCE PAGE 1617473 BEFORE USE.
�'
Design valid for use only with Mffek connectors. This design is based only upon parameters shown, and Is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members oNy. Additional temporary bracing to Insure stability during construction is the responslbillity of the
Additional bracing the is the
Mffek°
erector. permanent of overall structure responsibility of the building designer. For general guidance regarding
fabrication quality control, storage, delivery, erection and bracing, consult ANSI/fP11 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East BNd,
Safety InformaFion avaI able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
If Southem Pine fSP) lumber is specified, the design values are those effective 06/01/2013 by ALSO
Tampa, FL 33610-4115
Symbols Numbering System J& General Safety Notes
PLATE LOCATION AND ORIENTATION
3/4 Center plate on joint unless x, y
offsets are indicated.
Dimensions.are in ff-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
0-'/1d'
For 4 x 2 orientation, locate
plates 0-IQ' from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
' Plate location details available in MiTek 20/20
software or upon request.
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Industry Standards:
ANSI/TPI1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
T
ly
M
6-4-8 dimensions shown in ff-in-sixteenths
(Drawings not to scale)
2
TOP CHORDS
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
[CC -ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Southern Pine lumber designations are as follows:
SYP represents values as published
by AWC in the 2005/2012 NDS
SP represents ALSC approved/new values
with effective date of June 1, 2013
© 2012 MiTekO All Rights Reserved
W1
MiTek"
MiTek Engineering Reference Sheet: MII-7473 rev. 02/26/2013
Failure to Follow Could Cause Property
Damage or Personal Injury
l . Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI,
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane atjoint
locations are regulated by ANSI/TPI 1,
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10, Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purlins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft, spacing,
or less, If no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless Indicated otherwise,
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture in accordance with
ANSI/TPI 1 Quality Criteria,