11.5.20 Brennan Residence Load Calcs
Building Analysis Job: Brennan Residence *'Vr�oCalcs® 9 Date: Oct 29,2020 AHU_ y Digitally signed is Jayvee La u 'Weave the missing piece' �•"I�u�JCdICS" ThomasVPlatania �' y y g ProCalcs LLC CgC815$5111-"''"` Date:2020.10.29 1 1:20:00-04'00' P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 Project • • For: Brennan Residence 12094 NW Harbour Ridge Blvd,Palm City,FL 34990 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl,FL,US Indoor temperature(°F) 70 75 Elevation: 26 ft Design TD(°F) 29 15 Latitude: 280N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 24.4 56.9 Dry bulb(°F) 41 90 Infiltration: Daily range(°F) - 15 ( L ) Method Blower door Wet bulb(°F) - 77 Shielding/stories 3(partial)/1 Wind speed(mph) 15.0 7.5 Pressure/AVF 50Pa/2751 cfm Component Btuh/ft2 Btuh %of load Walls 3.7 7816 24.7 Glazing 12.8 6391 20.2 walls Ducts Doors 11.3 241 0.8 Ceilings 0.9 2447 7.7 Floors 1.3 3021 9.5 Infiltration 2.1 4917 15.5 Ducts 6847 21.6 Piping 0 0 Infiltration Humidification 0 0 Glazing Ventilation 0 0 Adjustments 0 Other Floors Total 31681 100.0 Ceilings • • Component Btuh/ft2 Btuh %of load Walls 3.0 6381 18.4 Internal Gains Glazing 21.2 10599 30.6 Walls Doors 11.4 244 0.7 Ceilings 1.4 3650 10.5 Floors 0 0 0 Ducts Infiltration 0.6 1464 4.2 Ducts 9357 27.0 Ventilation 0 0 Internal gains 2955 8.5 Glazing Blower 0 0 Infiltration Adjustments 0 Total 34649 100.0 Other Ceilings Latent Cooling Load=6523 Btuh Overall U-value=0.089 Btuh/ft2-OF Data entries checked. wrightsoft- 2020-Oct-29 21:27:45 A -- Right-Suite@ Universal 2019 19.0.21 RSU26566 Page rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces: E Building Analysis Job: Brennan Residence *'Vr�oCalcs® 9 Date: Oct 29,2020 'We are the missing piece' AHU- 2 By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 Project • • For: Brennan Residence 12094 NW Harbour Ridge Blvd,Palm City,FL 34990 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl,FL,US Indoor temperature(°F) 70 75 Elevation: 26 ft Design TD(°F) 29 15 Latitude: 280N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 24.4 56.9 Dry bulb(°F) 41 90 Infiltration: Daily range(°F) - 15 ( L ) Method Blower door Wet bulb(°F) - 77 Shielding/stories 3(partial)/1 Wind speed(mph) 15.0 7.5 Pressure/AVF 50Pa/2751 cfm Component Btuh/ft2 Btuh %of load Walls 4.2 5891 34.3 Glazing 12.8 1904 11.1 Ducts Doors 0 0 0 Ceilings 0.9 1052 6.1 Walls Floors 1.9 2177 12.7 Infiltration 2.1 3222 18.8 Infiltration Ducts 2929 17.1 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Glazing rFloors Total 17176 1 100.0 Ceilings Component Btuh/ft2 Btuh %of load Walls 3.5 4936 28.6 Internal Gains Glazing 27.8 4157 24.0 Doors 0 0 0 Walls Ceilings 1.5 1666 9.6 Floors 0 0 0 Ducts Infiltration 0.6 959 5.5 Ducts 3980 23.0 Ventilation 0 0 Internal gains 1590 9.2 Blower 0 0 Infiltration Adjustments 0 Glazing Ceilings Total 17289 100.0 Latent Cooling Load=4064 Btuh Overall U-value=0.099 Btuh/ft2-OF Data entries checked. wrightsoft- 2020-Oct-29 21:27:45 A -- M,.<..,e<.,,.< ,.a_,.<o Right-Suite@ Universal 201919.0.21 RSU26566 Page rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces: E Load Short Form Job: Brennan Residence *-V o)Ca'CS® Date: Oct 29,2020 We are the missing piece' AHU_ y By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Finail:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 Project • • For: Brennan Residence 12094 NW Harbour Ridge Blvd,Palm City,FL 34990 Design Information Htg Clg Infiltration Outside db(°F) 41 90 Method Blower door Inside db(°F) 70 75 Shielding/stories 3(partial)/1 Design TD(°F) 29 15 Pressure/AVF 50 Pa/2751 cfm Daily range - L Inside humidity(%) 50 50 Moisture difference(gr/Ib) 24 57 HEATING EQUIPMENT COOLING EQUIPMENT Make Rheem Make Rheem Trade RHEEM Trade RHEEM Model RBHP-24J11 SH* Cond RAND-048JAZ AHRI ref Coil RBHP-24J11 SHD AHRI ref N/A,Existing Efficiency 100 EFF Efficiency 12.1 EER, 13.5 SEER Heating input 10.0 kW Sensible cooling 48300 Btuh Heating output 34121 Btuh Latent cooling 9200 Btuh Temperature rise 19 OF Total cooling 57500 Btuh Actual air flow 1605 cfm Actual air flow 1605 cfm Airflowfactor 0.051 cfm/Btuh Airflowfactor 0.046 cfm/Btuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.84 ROOM NAME Area Htg load Clg load Htg AVF CIgAVF (ft2) (Btuh) (Btuh) (cfm) (cfm) ATRIUM 403 1350 1293 68 60 BATH 2 72 102 219 5 10 BATH 3 75 1980 1174 100 54 BEDROOM 2 214 2060 1435 104 66 BEDROOM 3 238 3175 1977 161 92 DINING ROOM 189 2658 2623 135 121 FOYER 121 2543 2501 129 116 HALF BATH 45 293 208 15 10 HALL 66 0 0 0 0 GREAT ROOM 773 11496 16889 582 782 LAUNDRY 77 1087 1273 55 59 NEW PANTRY 88 782 518 40 24 OP E N TO B E LOW 112 3556 3992 180 185 WIC 2 22 34 214 2 10 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2020-Oct-29 21:27:45 A-- 1-- ,., "h.w y, _P.., Right-Suite@ Universal 2019 19.0.21 RSU26566 Page 1 ACCA ...rking Drawings\Brennan Residence Load Calcs.rup Cale=MJ8 Front Door faces: E WIC 3 28 565 333 29 15 AHU-1 2521 31681 34649 1605 1605 Other equip loads 0 0 Equip.@ 1.00 RSM 34649 Latent cooling 6523 TOTALS 2521 31681 41172 1605 1605 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2020-Oct-29 21:27:45 "'h'w", _P. Right-Suite@ Universal 2019 19.0.21 RSU26566 Page ACCA ...rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces: E Load Short Form Job: Brennan Residence *--[P o)Ca'CS® Date: Oct 29,2020 We are the missing piece' AHU- 2 By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Finail:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 Project Information For: Brennan Residence 12094 NW Harbour Ridge Blvd,Palm City,FL 34990 Design Information Htg Clg Infiltration Outside db(°F) 41 90 Method Blower door Inside db(°F) 70 75 Shielding/stories 3(partial)/1 Design TD(°F) 29 15 Pressure/AVF 50 Pa/2751 cfm Daily range - L Inside humidity(%) 50 50 Moisture difference(gr/Ib) 24 57 HEATING EQUIPMENT COOLING EQUIPMENT Make Rheem Make Rheem Trade RHEEM Trade RHEEM Model RBHP-17J06SH* Cond RAND-024JAZ AHRI ref Coil RBHP-17J06SHD AHRI ref N/A,Existing Efficiency 100 EFF Efficiency 12.1 EER, 14 SEER Heating input 4.9 kW Sensible cooling 18792 Btuh Heating output 16719 Btuh Latent cooling 4408 Btuh Temperature rise 19 OF Total cooling 23200 Btuh Actual air flow 804 cfm Actual air flow 804 cfm Airflowfactor 0.047 cfm/Btuh Airflowfactor 0.047 cfm/Btuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.81 ROOM NAME Area Htg load Clg load Htg AVF CIgAVF (ft2) (Btuh) (Btuh) (cfm) (cfm) LIVING ROOM 360 4669 7197 219 335 M BATH 208 2933 1871 137 87 M CLOS 61 1533 923 72 43 M TOILET 29 994 587 47 27 M WIC 1 46 879 655 41 30 M W IC 2 58 477 333 22 15 MASTER BEDROOM 373 5692 5722 266 266 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2020-Oct-29 21:27:45 A-- 1-- ,.„ "h'w", _P. Right-Suite@ Universal 2019 19.0.21 RSU26566 Page 3 ACCA ...rking Drawings\Brennan Residence Load Calcs.rup Cale=MJ8 Front Door faces: E AHU-2 1134 17176 17289 804 804 Other equip loads 0 0 Equip.@ 1.00 RSM 17289 Latent cooling 4064 TOTALS 1134 17176 21353 804 804 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2020-Oct-29 21:27:45 "'h'w", _P. Right-Suite@ Universal 2019 19.0.21 RSU26566 Page ACCP. ...rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces: E Component Constructions Job: Brennan Residence *--W�OCa'CS® Date: Oct 29,2020 'We are the missing piece' AHU- y By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Finail:tom@°procalcs.net Web:www.ProCalcs.Net License:CAC1815254 Project • • For: Brennan Residence 12094 NW Harbour Ridge Blvd,Palm City,FL 34990 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl,FL,US Indoor temperature(°F) 70 75 Elevation: 26 ft Design TD(°F) 29 15 Latitude: 280N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 24.4 56.9 Dry bulb(°F) 41 90 Infiltration: Daily range(°F) - 15 ( L ) Method Blower door Wet bulb(°F) - 77 Shielding/stories 3(partial)/1 Wind speed(mph) 15.0 7.5 Pressure/AVF 50Pa/2751 cfm Construction descriptions Or Area Uwalue Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ft"F ft"F/Btuh Btuh/ft2 Btuh Btuh/ft� Btuh Walls Block Wall R-4.1 n 604 0.155 4.1 4.49 2713 3.77 2273 e 403 0.155 4.1 4.49 1810 3.77 1516 s 213 0.155 4.1 4.49 957 3.77 802 W 345 0.155 4.1 4.49 1551 3.77 1299 all 1564 0.155 4.1 4.49 7031 3.77 5891 Knee Wall R-30 n 63 0.032 30.0 0.93 58 0.78 49 e 73 0.032 30.0 0.93 68 0.78 57 s 63 0.032 30.0 0.93 58 0.78 49 W 115 0.032 30.0 0.93 107 0.78 89 all 314 0.032 30.0 0.93 291 0.78 244 Partitions Frame Wall 2 x 6 R-19 258 0.066 19.0 1.92 494 0.95 245 Windows Double PaneAlum:Double Pane Alum;NFRC rated(SHGC=0.25);50% n 8 0.440 0 12.8 102 10.8 86 blinds 450,medium;foreground=green grass(0.23);3 ft overhang(2.67 ft e 24 0.440 0 12.8 306 13.9 333 Window ht,0 ft sep.); 10 ft head ht s 8 0.440 0 12.8 102 12.8 102 all 40 0.440 0 12.8 510 13.0 521 Double PaneAlum:Double Pane Alum;NFRC rated(SHGC=0.25);50% n 9 0.440 0 12.8 120 10.8 101 blinds 450,medium;foreground=green grass(0.23);3 ft overhang(4.17 ft Window ht,0 ft sep.);8 ft head ht Double PaneAlum:Double Pane Alum;NFRC rated(SHGC=0.25);50% n 24 0.440 0 12.8 301 10.8 254 blinds 450,medium;foreground=green grass(0.23);3 ft overhang(5.25 ft Window ht,0 ft sep.);8 ft head ht Double PaneAlum:Double Pane Alum;NFRC rated(SHGC=0.25);50% n 21 0.440 0 12.8 268 10.8 226 blinds 450,medium;foreground=green grass(0.23);3 ft overhang(5.25 ft Window ht,2.15 ft sep.);8 ft head ht Double PaneAlum:Double Pane Alum;NFRC rated(SHGC=0.25);50% e 25 0.440 0 12.8 319 29.2 729 blinds 450,medium;foreground=green grass(0.23);3 ft overhang(5 ft window ht,2.33 ft sep.);8 ft head ht wrightsoft- 2020-Oct-29 21:27:45 Right-Suite@ Universal 2019 19.0.21 RSU26566 Page 1 ACCP. ...rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces: E Double PaneAlum:Double Pane Alum;NFRC rated(SHGC=0.25);50% a 16 0.440 0 12.8 201 21.7 342 blinds 45°,medium;foreground=green grass(0.23);8 ft overhang(10.5 ft e 17 0.440 0 12.8 212 21.7 361 window ht, 1.67 ft sep.); 10.5 ft head ht a 32 0.440 0 12.8 402 15.8 497 all 64 0.440 0 12.8 815 18.8 1199 Double PaneAlum:Double Pane Alum;NFRC rated(SHGC=0.25);50% s 128 0.440 0 12.8 1633 12.8 1633 blinds 45°,medium;foreground=green grass(0.23);3 ft overhang(8 ft window ht,0 ft sep.);8 ft heed ht Double PaneAlum:Double Pane Alum;NFRC rated(SHGC=0.25);50% w 42 0.440 0 12.8 536 20.7 868 blinds 45°,medium;foreground=green grass(0.23);3 ft overhang(4.67 ft window ht,0 ft sep.); 10 ft heed ht Double PaneAlum:Double Pane Alum;NFRC rated(SHGC=0.25);50% w 82 0.440 0 12.8 1046 22.7 1860 blinds 45°,medium;foreground=green grass(0.23);3 ft overhang(6 ft w 66 0.440 0 12.8 842 22.7 1497 windouu ht,0 ft sep.);8 ft head ht all 148 0.440 0 12.8 1888 22.7 3356 Doors Solid Wood Core n 21 0.390 0 11.3 241 11.4 244 Ceilings Vented Metal Roof R-30 2516 0.032 30.0 0.93 2335 1.37 3446 121 0.032 30.0 0.93 112 1.69 204 all 2637 0.032 30.0 0.93 2447 1.38 3650 Floors Slab on grade 179 0.582 0 16.9 3021 0 0 wrlightsoft® 2020-Oct-292127:45 Right-Suite®Universal 2019 19.0.21 RSU26566 Page ACCP. ...rNng Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces:E Component Constructions Job: Brennan Residence *--W�OCa'CS® Date: Oct 29,2020 'We are the missing piece' AHU- 2 By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Finail:tom@°procalcs.net Web:www.ProCalcs.Net License:CAC1815254 Project Information For: Brennan Residence 12094 NW Harbour Ridge Blvd,Palm City,FL 34990 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl,FL,US Indoor temperature(°F) 70 75 Elevation: 26 ft Design TD(°F) 29 15 Latitude: 280N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 24.4 56.9 Dry bulb(°F) 41 90 Infiltration: Daily range(°F) - 15 ( L ) Method Blower door Wet bulb(°F) - 77 Shielding/stories 3(partial)/1 Wind speed(mph) 15.0 7.5 Pressure/AVF 50Pa/2751 cfm Construction descriptions Or Area Uwalue Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ft"F ft"F/Btuh Btuh/ft2 Btuh Btuh/ft� Btuh Walls Block Wall R-4.1 n 207 0.155 4.1 4.49 930 3.77 780 e 227 0.155 4.1 4.49 1018 3.77 853 s 553 0.155 4.1 4.49 2485 3.77 2082 W 299 0.155 4.1 4.49 1342 3.77 1124 all 1285 0.155 4.1 4.49 5775 3.77 4839 Knee Wall R-30 n 43 0.032 30.0 0.93 40 0.78 33 e 39 0.032 30.0 0.93 36 0.78 30 s 43 0.032 30.0 0.93 40 0.78 33 all 125 0.032 30.0 0.93 116 0.78 97 Partitions (none) Windows Double PaneAlum:Double Pane Alum;NFRC rated(SHGC=0.25);50% s 19 0.440 0 12.8 239 12.8 239 blinds 450,medium;foreground=green grass(0.23);3 ft overhang(3 ft Window ht,0 ft sep.);8 ft head ht Double PaneAlum:Double Pane Alum;NFRC rated(SHGC=0.25);50% s 24 0.440 0 12.8 306 12.8 306 blinds 450,medium;foreground=green grass(0.23);3 ft overhang(6 ft Window ht,2 ft sep.);8 ft head ht Double PaneAlum:Double Pane Alum;NFRC rated(SHGC=0.25);50% W 40 0.440 0 12.8 510 28.6 1143 blinds 450,medium;foreground=green grass(0.23);3 ft overhang(5 ft Window ht,2.15 ft sep.);8 ft head ht Double PaneAlum:Double Pane Alum;NFRC rated(SHGC=0.25);50% W 67 0.440 0 12.8 849 18.6 1236 blinds 450,medium;foreground=green grass(0.23);3 ft overhang(10.5 ft Window ht,0 ft sep.); 12 ft head ht Doors (none) Ceilings Vented Metal Roof R-30 779 0.032 30.0 0.93 723 1.37 1067 355 0.032 30.0 0.93 329 1.69 599 all 1134 0.032 30.0 0.93 1052 1.47 1666 wrightsoft- 2020-Oct-29 21:27:45 Right-Suite@ Universal 2019 19.0.21 RSU26566 Page ACCP. ...rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces: E Floors Slab on grade 129 0.582 0 16.9 2177 0 0 -1141-111- wrightsoft® 2020-Oct-292127:45 Right-Suite(g)Universal 2019 19.0.21 RSU26566 Page ACCP. ...rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces:E Project S Job: Brennan Residence *-a[Pr�o ro ummaCal�s® rY Date: Oct 29,2020 We are the missing piece' AHU- y By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 Proiect Information For: Brennan Residence 12094 NW Harbour Ridge Blvd,Palm City,FL 34990 Notes: A E M&Associattes LLC 3 Ridgewood Circle Jupiter,FL 33469 Desicin Information Weather: St Lucie Co Intl,FL,US Winter Design Conditions Summer Design Conditions Outside db 41 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 29 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 24834 Btuh Structure 25293 Btuh Ducts 6847 Btuh Ducts 9357 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31681 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 34649 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3 All /1 Pressure/AVF 50Pa/All cfm Structure 3543 Btuh Ducts 2980 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 2529 252 Equipment latent load 6523 Btuh Volume(ft3) 27420 27420 Air changes/hour 0.34 0.19 Equipment Total Load(Seiril 41172 Btuh Equiv.AVF(cfm) 154 87 Req.total capacity at 0.84 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make Rheem Make Rheem Trade RHEEM Trade RHEEM Model RBHP-24J11 SH* Cond RAND-048JAZ AHRI ref Coil RBHP-24J11 SHD AHRI ref N/A,Existing Efficiency 100 EFF Efficiency 12.1 EER, 13.5 SEER Heating input 10.0 kW Sensible cooling 48300 Btuh Heating output 34121 Btuh Latent cooling 9200 Btuh Temperature rise 19 OF Total cooling 57500 Btuh Actual air flow 1605 cfm Actual air flow 1605 cfm Airflowfactor 0.051 cfm/Btuh Airflowfactor 0.046 cfm/Btuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrilla"I ft® 2020-Oct-29 21:27:45 —.1 1a -_-!T !- Right-Suite@ Universal 2019 19.0.21 RSU26566 Page 1 ACCP. ...rking Drawings\Brennan Residence Load Calcs.rup Cale=MJ8 Front Door faces: E Project S Job: Brennan Residence *-a[Pr�o ro ummaCal�s® rY Date: Oct 29,2020 We are the missing piece' AHU-2 By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 Proiect Information For: Brennan Residence 12094 NW Harbour Ridge Blvd,Palm City,FL 34990 Notes: A E M&Associattes LLC 3 Ridgewood Circle Jupiter,FL 33469 Desicin Information Weather: St Lucie Co Intl,FL,US Winter Design Conditions Summer Design Conditions Outside db 41 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 29 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 14247 Btuh Structure 13308 Btuh Ducts 2929 Btuh Ducts 3980 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 17176 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17289 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3 All /1 Pressure/AVF 50Pa/All cfm Structure 2791 Btuh Ducts 1274 Btuh Central vent(0 cfm) 0 Btuh Heating cooling (none) Area(ft2) 1134 1134 Equipment latent load 4064 Btuh Volume(ft3) 13027 13027 Air changes/hour 0.47 0.26 Equipment Total Load(Seiril 21353 Btuh Equiv.AVF(cfm) 101 57 Req.total capacity at 0.81 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Rheem Make Rheem Trade RHEEM Trade RHEEM Model RBHP-17J06SH* Cond RAND-024JAZ AHRI ref Coil RBHP-17J06SHD AHRI ref N/A,Existing Efficiency 100 EFF Efficiency 12.1 EER, 14 SEER Heating input 4.9 kW Sensible cooling 18792 Btuh Heating output 16719 Btuh Latent cooling 4408 Btuh Temperature rise 19 OF Total cooling 23200 Btuh Actual air flow 804 cfm Actual air flow 804 cfm Airflowfactor 0.047 cfm/Btuh Airflowfactor 0.047 cfm/Btuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrilla"I ft® 2020-Oct-29 21:27:45 —.1 1a -_-!T !- Right-Suite@ Universal 2019 19.0.21 RSU26566 Page ACCP. ...rking Drawings\Brennan Residence Load Calcs.rup Cale=MJ8 Front Door faces: E '� roCalcs@ Right-JO Worksheet Job: Brennan Residence �� we°rcmemnsingp-e �u� _ Date: Oct 29,2020 n I By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 1 Room name AHU-1 ATRIUM 2 Exposed wall 223.0 It 0 ft 3 Room height 10.9 It 10.7 It heat/cool 4 Room dimensions 1.0 x 403.3 ft 5 Room area 2521.3 ft' 403.3 ft2 Ty Construction U-value Or HTM Area W) Load Area M) Load number (Btuh/> -F) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V Block W all R-4.1 0.155 n 4.49 3.77 666 604 2713 2273 65 65 290 243 Double PaneA unn 0.440 n 12.76 10.76 8 0 102 86 0 0 0 0 Double PaneA unn 0.440 n 12.76 10.76 9 0 120 101 0 0 0 0 Double PaneA unn 0.440 n 12.76 10.76 24 0 301 254 0 0 0 0 11 Double PaneA unn 0.440 n 12.76 10.76 21 0 268 226 0 0 0 0 W Knee W all R-30 0.032 n 0.93 0.78 63 63 58 49 0 0 0 0 Block W all R-4.1 0.155 a 4.49 3.77 516 403 1810 1516 18 18 81 68 Double PaneA unn 0.440 a 12.76 13.88 24 45 306 333 0 0 0 0 Double PaneA urn 0.440 a 12.76 29.18 25 2 319 729 0 0 0 0 Double PaneA urn 0.440 a 12.76 21.69 16 15 201 342 0 0 0 0 Double PaneA urn 0.440 a 12.76 21.69 17 16 212 361 0 0 0 0 Double PaneA unn 0.440 a 12.76 15.78 32 30 402 497 0 0 0 0 W Knee W all R-30 0.032 a 0.93 0.78 73 73 68 57 0 0 0 0 Block W all R-4.1 0.155 s 4.49 3.77 349 213 957 802 26 26 115 96 Double PaneA unn 0.440 s 12.76 12.76 8 16 102 102 0 0 0 0 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 12.76 12.76 128 256 1633 1633 0 0 0 0 W Knee W all R-30 0.032 s 0.93 0.78 63 63 58 49 0 0 0 0 Block W all R-4.1 0.155 w 4.49 3.77 535 345 1551 1299 0 0 0 0 Double PaneA unn 0.440 w 12.76 20.67 42 45 536 868 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 22.68 82 68 1046 1860 0 0 0 0 Double PaneA unn 0.440 w 12.76 22.68 66 55 842 1497 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 w 0.93 0.78 115 115 107 89 0 0 0 0 Frame W all 2 x 6 R-1 0.066 - 1.92 0.95 279 258 494 245 0 0 0 0 D Solid Wood Core 0.390 n 11.31 11.43 21 21 241 244 0 0 0 0 C vented Metal Roof R- 0.032 0.93 1.37 2516 2516 2335 3446 370 370 343 507 C vented Metal Roof R- 0.032 0.93 1.69 121 121 112 204 0 0 0 0 F Slab on grade 0.582 16.88 0.00 2409 179 3021 0 403 0 0 0 6 c)AED excursion 1711 -45 Envelope loss/gain 19917 20874 829 869 12 a) Infiltration 4917 1464 223 66 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 2725 0 Subtotal(lines 6 to 13) 24834 25293 1052 935 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 6 8 14 Subtotal 24834 25293 1058 944 15 Ductloads 289/ 379/ 6847 9357 28°/ 37°/ 292 349 FFTotal room load 31681 34649 1350 1293 Ajr required(cfm) 1 6051 1605 68 60 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -ri- wrigFmtsoTrt® 2020-Oct-2921:27:45 . A -•w-w• Right-Suite®Universal 2019 19.0.21 RSU26566 Pagel rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces:E '� roCalcs@ Right-JO Worksheet Job: Brennan Residence �� we°rcmemnsingp-e �u� _ Date: Oct 29,2020 n I By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAM 815254 1 Room name BATH 2 BATH 3 2 Exposed wall 0 ft 18.5 ft 3 Room height 9.0 ft heaUcool 9.0 ft heat/cool 4 Room dimensions 8.5 x 8.5 ft 6.0 x 12.5 ft 5 Room area 72.3 ft2 75.0 ft2 Ty Construction U-value Or HTM Area M2) Load Area M2) Load number (BtuhA?-°F) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V Block W all R-4.1 0.155 n 4.49 3.77 0 0 0 0 113 103 464 388 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 9 0 120 101 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 11 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 n 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 a 4.49 3.77 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 e 12.76 13.88 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 12.76 29.18 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 12.76 21.69 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 12.76 21.69 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 e 12.76 15.78 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 a 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 s 4.49 3.77 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 s 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 w 4.49 3.77 0 0 0 0 54 54 243 203 Double PaneA unn 0.440 w 12.76 20.67 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 22.68 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 22.68 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 w 0.93 0.78 0 0 0 0 0 0 0 0 Frame W all 2 x 6 R-1 0.066 - 1.92 0.95 0 0 0 0 0 0 0 0 D Solid Wood Core 0.390 n 11.31 11.43 0 0 0 0 0 0 0 0 C vented Metal Roof R- 0.032 0.93 1.37 72 72 67 99 75 75 70 103 C vented Metal Roof R- 0.032 0.93 1.69 0 0 0 0 0 0 0 0 F Slab on grade 0.582 16.88 0.00 72 0 0 0 75 19 312 0 6 c)AED excursion -7 -41 Envelope loss/gain 67 92 1208 754 12 a) Infiltration 0 0 344 102 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 50 0 Subtotal(lines 6 to 13) 67 142 1552 857 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 13 18 0 0 14 Subtotal 80 160 1552 857 15 Duct loads 289/ 379/ 22 59 28% 379/ 428 317 Total room load 102 219 1980 1174 Air required(cfm) 5 10 100 54 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -ri- wrigFmtsoTrt® 2020-Oct-2921:27:45 . A -•w-w• Right-Suite®Universal 2019 19.0.21 RSU26566 Page rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces:E '� roCalcs@ Right-JO Worksheet Job: Brennan Residence �� we°rcmemnsingp-e �u� _ Date: Oct 29,2020 n I By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAM 815254 1 Room name BEDROOM2 BEDROOMS 2 Exposed wall 16.0 ft 31.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 214.0 ft 17.0 x 14.0 ft 5 Room area 214.0 ft' 238.0 ft2 Ty Construction U-value Or HTM Area M2) Load Area M) Load number (BtuhA?-°F) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V Block W all R-4.1 0.155 n 4.49 3.77 144 120 541 453 126 105 472 395 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 n 12.76 10.76 24 0 301 254 0 0 0 0 11 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 21 0 268 226 W Knee W all R-30 0.032 n 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 a 4.49 3.77 0 0 0 0 95 95 425 356 Double PaneA unn 0.440 e 12.76 13.88 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 12.76 29.18 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 12.76 21.69 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 12.76 21.69 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 e 12.76 15.78 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 a 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 s 4.49 3.77 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 s 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 w 4.49 3.77 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 20.67 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 22.68 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 22.68 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 w 0.93 0.78 0 0 0 0 0 0 0 0 Frame W all 2 x 6 R-1 0.066 - 1.92 0.95 0 0 0 0 59 59 112 56 D Solid Wood Core 0.390 n 11.31 11.43 0 0 0 0 0 0 0 0 C vented Metal Roof R- 0.032 0.93 1.37 214 214 199 293 238 238 221 326 C vented Metal Roof R- 0.032 0.93 1.69 0 0 0 0 0 0 0 0 F Slab on grade 0.582 16.88 0.00 214 16 270 0 238 31 523 0 6 c)AED excursion -50 -68 Envelope loss/gain 1311 951 2021 1291 12 a) Infiltration 298 89 456 136 b) Room ventilation 0 0 1 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1609 1039 2477 1426 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 8 12 17 14 Subtotal 1615 1048 2489 1443 15 Duct loads 28% 37% 445 388 28% 37%1 686 534 Total room load 2060 1435 3175 1977 Air required(cfm) 104 66 161 92 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -ri- wrigFmtsoTrt® 2020-Oct-2921:27:45 . A -•w-w• Right-Suite®Universal 2019 19.0.21 RSU26566 Page rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces:E '� roCalcs@ Right-JO Worksheet Job: Brennan Residence �� we°rcmemnsingp-e �u� _ Date: Oct 29,2020 n I By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAM 815254 1 Room name DINING ROOM FOYER 2 Exposed wall 16.0 ft 10.0 ft 3 Room height 12.0 ft heat/cool 14.0 ft heat/cool 4 Room dimensions 14.5 x 13.0 ft 10.5 x 11.5 ft 5 Room area 188.5 it2 120.8 it2 Ty Construction U-value Or HTM Area M2) Load Area M) Load number (BtuhA?-°F) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V Block W all R-4.1 0.155 n 4.49 3.77 39 39 175 147 0 0 0 0 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 11 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 n 0.93 0.78 0 0 0 0 23 23 21 18 Block W all R-4.1 0.155 a 4.49 3.77 156 131 589 493 143 79 353 296 Double PaneA unn 0.440 a 12.76 13.88 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 a 12.76 29.18 25 1 319 729 0 0 0 0 Double PaneA urn 0.440 a 12.76 21.69 0 0 0 0 16 7 201 342 Double PaneA urn 0.440 a 12.76 21.69 0 0 0 0 17 8 212 361 Double PaneA unn 0.440 a 12.76 15.78 0 0 0 0 32 15 402 497 W Knee W all R-30 0.032 a 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 s 4.49 3.77 18 18 81 68 8 8 34 28 Double PaneA unn 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 s 0.93 0.78 0 0 0 0 23 23 21 18 Block W all R-4.1 0.155 w 4.49 3.77 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 20.67 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 22.68 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 22.68 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 w 0.93 0.78 0 0 0 0 21 21 19 16 Frame W all 2 x 6 R-1 0.066 - 1.92 0.95 18 18 35 17 0 0 0 0 D Solid Wood Core 0.390 n 11.31 11.43 0 0 0 0 0 0 0 0 C vented Metal Roof R- 0.032 0.93 1.37 189 189 175 258 0 0 0 0 C vented Metal Roof R- 0.032 0.93 1.69 0 0 0 0 121 121 112 204 F Slab on grade 0.582 16.88 0.00 189 16 270 0 121 10 169 0 6 c)AED excursion 70 -87 Envelope loss/gain 1644 1783 1545 1692 12 a) Infiltration 440 131 448 134 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2084 1914 1994 1826 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2084 1914 1994 1826 15 Duct loads 289/ 379/ 575 708 28/ 37% 550 675 Total room load 2658 2623 2543 2501 Air required(cfm) 1351 121 129 116 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -ri- wrigFmtsoTrt® 2020-Oct-2921:27:45 . A -•w-w• Right-Suite®Universal 2019 19.0.21 RSU26566 Page rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces:E '� roCalcs@ Right-JO Worksheet Job: Brennan Residence �� we°rcmemnsingp-e �u� _ Date: Oct 29,2020 n I By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAM 815254 1 Room name HALF BATH HALL 2 Exposed wall 5.5 ft 0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 45.3 ft 16.5 x 4.0 ft 5 Room area 45.3 ft' 66.0 ft2 Ty Construction U-value Or HTM Area M2) Load Area M2) Load number (Btuh/> -F) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V Block W all R-4.1 0.155 n 4.49 3.77 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 11 Double PaneAlUm 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 n 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 a 4.49 3.77 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 e 12.76 13.88 0 0 0 0 0 0 0 0 Double PaneAlum 0.440 e 12.76 29.18 0 0 0 0 0 0 0 0 Double PaneAlum 0.440 e 12.76 21.69 0 0 0 0 0 0 0 0 Double PaneAlum 0.440 e 12.76 21.69 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 e 12.76 15.78 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 a 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 s 4.49 3.77 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 s 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 w 4.49 3.77 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 w 12.76 20.67 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlum 0.440 w 12.76 22.68 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 w 12.76 22.68 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 w 0.93 0.78 0 0 0 0 0 0 0 0 Frame W all 2 x 6 R-1 0.066 - 1.92 0.95 50 50 95 47 0 0 0 0 D Solid Wood Core 0.390 n 11.31 11.43 0 0 0 0 0 0 0 0 C vented Metal Roof R- 0.032 0.93 1.37 45 45 42 62 66 66 61 90 C vented Metal Roof R- 0.032 0.93 1.69 0 0 0 0 0 0 0 0 F Slab on grade 0.582 16.88 0.00 45 6 93 0 66 0 0 0 6 c)AED excursion -7 -4 Envelope loss/gain 230 102 61 86 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 50 0 Subtotal(lines 6 to 13) 230 152 61 86 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 -61 -86 14 Subtotal 230 152 0 0 15 Duct loads 28% 37% 63 56 28% 37%1 0 0 FFTotal room load 293 208 0 0 Air required(cfm) 15 10 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -ri- 2020-Oct-2921:27:45 . A -•w-w• Right-Suite®Universal 2019 19.0.21 RSU26566 Page rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces:E '� roCalcs@ Right-JO Worksheet Job: Brennan Residence �� we°rcmemnsingp-e �u� _ Date: Oct 29,2020 n I By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAM 815254 1 Room name GREAT ROOM LAUNDRY 2 Exposed wall 52.5 ft 17.0 ft 3 Room height 12.6 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 772.8 ft 9.0 x 8.5 ft 5 Room area 772.8 ft' 76.5 ft2 Ty Construction U-value Or HTM Area M2) Load Area M2) Load number (BtuhA?-°F) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V Block W all R-4.1 0.155 n 4.49 3.77 90 90 405 339 0 0 0 0 Double PaneAlUm 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 11 Double PaneAlUm 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 n 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 a 4.49 3.77 38 38 169 141 0 0 0 0 Double PaneAlUm 0.440 e 12.76 13.88 0 0 0 0 0 0 0 0 Double PaneAlum 0.440 e 12.76 29.18 0 0 0 0 0 0 0 0 Double PaneAlum 0.440 e 12.76 21.69 0 0 0 0 0 0 0 0 Double PaneAlum 0.440 e 12.76 21.69 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 e 12.76 15.78 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 a 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 s 4.49 3.77 258 130 584 490 0 0 0 0 Double PaneAlUm 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 s 12.76 12.76 128 128 1633 1633 0 0 0 0 W Knee W all R-30 0.032 s 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 w 4.49 3.77 372 224 1007 844 0 0 0 0 Double PaneAlUm 0.440 w 12.76 20.67 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlum 0.440 w 12.76 22.68 82 34 1046 1860 0 0 0 0 Double PaneAlUm 0.440 w 12.76 22.68 66 27 842 1497 0 0 0 0 Double PaneAlUm 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 w 0.93 0.78 0 0 0 0 0 0 0 0 Frame W all 2 x 6 R-1 0.066 - 1.92 0.95 0 0 0 0 153 132 253 125 D Solid Wood Core 0.390 n 11.31 11.43 0 0 0 0 21 21 241 244 C vented Metal Roof R- 0.032 0.93 1.37 922 922 855 1262 77 77 71 105 C vented Metal Roof R- 0.032 0.93 1.69 0 0 0 0 0 0 0 0 F Slab on grade 0.582 16.88 0.00 773 53 886 0 77 17 287 0 6 c)AED excursion 1541 -45 Envelope loss/gain 7427 9606 852 429 12 a) Infiltration 1566 466 0 0 b) Room ventilation 0 0 1 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 2000 500 Subtotal(lines 6 to 13) 8993 12302 852 929 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 19 26 0 0 14 Subtotal 9012 12328 852 929 15 Ductloads 289/ 379/ 2485 4561 289/ 379/ 235 344 FTotal room load 11496 16889 1087 1273 Air required(cfm) 582 782 55 59 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -ri- wrigFmtsoTrt® 2020-Oct-2921:27:45 . A -•w-w• Right-Suite®Universal 2019 19.0.21 RSU26566 Page rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces:E '� roCalcs@ Right-JO Worksheet Job: Brennan Residence �� we°rcmemnsingp-e �u� _ Date: Oct 29,2020 n I By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAM 815254 1 Room name NEW PANTRY OPEN TO BELOW 2 Exposed wall 7.0 ft 44.0 ft 3 Room height 9.0 ft heaUcool 10.0 ft heat/cool 4 Room dimensions 7.0 x 12.5 ft 14.0 x 8.0 ft 5 Room area 87.5 ft' 112.0 its Ty Construction U-value Or HTM Area M2) Load Area M) Load number (BtuhA?-°F) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V Block W all R-4.1 0.155 n 4.49 3.77 0 0 0 0 40 32 144 121 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 8 0 102 86 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 11 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 n 0.93 0.78 0 0 0 0 40 40 37 31 Block W all R-4.1 0.155 a 4.49 3.77 0 0 0 0 67 43 193 162 Double PaneA unn 0.440 e 12.76 13.88 0 0 0 0 24 22 306 333 Double PaneA urn 0.440 e 12.76 29.18 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 12.76 21.69 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 12.76 21.69 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 e 12.76 15.78 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 a 0.93 0.78 0 0 0 0 73 73 68 57 Block W all R-4.1 0.155 s 4.49 3.77 0 0 0 0 40 32 144 121 Double PaneA unn 0.440 s 12.76 12.76 0 0 0 0 8 8 102 102 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 s 0.93 0.78 0 0 0 0 40 40 37 31 Block W all R-4.1 0.155 w 4.49 3.77 63 63 283 237 46 4 18 15 Double PaneA unn 0.440 w 12.76 20.67 0 0 0 0 42 22 536 868 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 22.68 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 22.68 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 w 0.93 0.78 0 0 0 0 94 94 87 73 Frame W all 2 x 6 R-1 0.066 - 1.92 0.95 0 0 0 0 0 0 0 0 D Solid Wood Core 0.390 n 11.31 11.43 0 0 0 0 0 0 0 0 C vented Metal Roof R- 0.032 0.93 1.37 88 88 81 120 112 112 104 153 C vented Metal Roof R- 0.032 0.93 1.69 0 0 0 0 0 0 0 0 F Slab on grade 0.582 16.88 0.00 88 7 118 0 0 0 0 0 6 c)AED excursion -18 491 Envelope loss/gain 483 339 1878 2644 12 a) Infiltration 130 39 909 271 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 613 378 2788 2914 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 613 378 2788 2914 15 Duct loads 289/ 379/ 169 140 28%1 379/ 769 1078 Total room load 782 518 3556 3992 Air required(cfm) 40 24 180 185 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -ri- wrigFmtsoTrt® 2020-Oct-2921:27:45 . A -•w-w• Right-Suite®Universal 2019 19.0.21 RSU26566 Page rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces:E '� roCalcs@ Right-JO Worksheet Job: Brennan Residence �� we°rcmemnsingp-e �u� _ Date: Oct 29,2020 n I By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAM 815254 1 Room name WIC 2 WIC 3 2 Exposed wall 0 ft 5.5 ft 3 Room height 9.0 ft heaUcool 9.0 ft heat/cool 4 Room dimensions 4.0 x 5.5 ft 5.0 x 5.5 ft 5 Room area 22.0 ft2 27.5 ft2 Ty Construction U-value Or HTM Area M2) Load Area M2) Load number (BtuhA?-°F) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V Block W all R-4.1 0.155 n 4.49 3.77 0 0 0 0 50 50 223 186 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 11 Double PaneA unn 0.440 n 12.76 10.76 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 n 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 a 4.49 3.77 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 e 12.76 13.88 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 12.76 29.18 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 12.76 21.69 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 12.76 21.69 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 e 12.76 15.78 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 a 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 s 4.49 3.77 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 s 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 w 4.49 3.77 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 20.67 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 22.68 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 22.68 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 w 0.93 0.78 0 0 0 0 0 0 0 0 Frame W all 2 x 6 R-1 0.066 - 1.92 0.95 0 0 0 0 0 0 0 0 D Solid Wood Core 0.390 n 11.31 11.43 0 0 01 0 0 0 0 0 C vented Metal Roof R- 0.032 0.93 1.37 22 22 20 30 28 28 26 38 C vented Metal Roof R- 0.032 0.93 1.69 0 0 0 0 0 0 0 0 F Slab on grade 0.582 16.88 0.00 22 0 0 0 28 6 93 0 6 c)AED excursion -7 -12 Envelope loss/gain 20 23 341 212 12 a) Infiltration 0 0 102 30 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 125 0 Subtotal(lines 6 to 13) 20 148 443 243 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 8 0 0 14 Subtotal 26 156 443 243 15 Duct loads 28% 37%1 7 58 28% 37%1 122 90 Total room load 34 214 565 333 Air required(cfm) 2 10 29 15 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -ri- wrigFttsoT*- 2020-Oct-2921:27:45 . A -•w-w• Right-Suite®Universal 2019 19.0.21 RSU26566 Page rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces:E '� roCalcs@ Right-JO Worksheet Job: Brennan Residence �� we°rcmemnsingp-e �u� _ L n Date: Oct 29,2020 n By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAM 815254 1 Room name AHU-2 LIVING ROOM 2 Exposed wall 129.0 ft 26.0 ft 3 Room height 11.5 ft 14.0 ft heat/cool 4 Room dimensions 1.0 x 359.8 ft 5 Room area 1133.8 ft2 359.8 ft2 Ty Construction U-value Or HTM Area M) Load Area M) Load number (Btuh/i -F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V Block W all R-4.1 0.155 n 4.49 3.77 207 207 930 780 0 0 0 0 Double PaneA unn 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 11 Double PaneA unn 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 n 0.93 0.78 43 43 40 33 43 43 40 33 Block W all R-4.1 0.155 a 4.49 3.77 227 227 1018 853 0 0 0 0 Double PaneA unn 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 a 0.93 0.78 39 39 36 30 33 33 30 26 Block W all R-4.1 0.155 s 4.49 3.77 596 553 2485 2082 120 120 539 452 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 12.76 12.76 19 38 239 239 0 0 0 0 Double PaneA unn 0.440 s 12.76 12.76 24 48 306 306 0 0 0 0 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 s 0.93 0.78 43 43 40 33 20 20 19 16 Block W all R-4.1 0.155 w 4.49 3.77 405 299 1342 1124 225 159 712 597 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 28.57 40 5 510 1143 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 18.59 67 32 849 1236 67 16 849 1236 W Knee W all R-30 0.032 w 0.00 0.00 0 0 0 0 0 0 0 0 Frame W all 2 x 6 R-1 0.066 - 0.00 0.00 0 0 0 0 0 0 0 0 D Solid Wood Core 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 C vented Metal Roof R- 0.032 0.93 1.37 779 779 723 1067 6 6 6 8 C vented Metal Roof R- 0.032 0.93 1.69 355 355 329 599 354 354 328 598 F Slab on grade 0.582 16.88 0.00 1134 129 2177 0 360 26 439 0 6 c)AED excursion 1233 714 Envelope loss/gain 11025 10759 2962 3679 12 a) Infiltration 3222 959 911 271 b) Room ventilation 0 0 1 0 0 13 Internal gains: Occupants @ 230 3 690 3 690 Appliances/other 900 900 Subtotal(lines 6 to 13) 14247 13308 3873 5540 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 14247 13308 3873 5540 15 Duct loads 21% 30°/ 2929 3980 21% 30°/ 7976 1657 Total room load 17176 17289 4669 7197 Air required(cfm) 804 804 219 335 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -ri- wrigFmtsoTrt® 2020-Oct-2921:27:45 . A -•w-w• Right-Suite®Universal 2019 19.0.21 RSU26566 Page rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces:E '� roCalcs@ Right-JO Worksheet Job: Brennan Residence �� we°rcmemnsingp-e �u� _ L n Date: Oct 29,2020 n By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAM 815254 1 Room name M BATH M CLOS 2 Exposed wall 29.5 ft 16.0 ft 3 Room height 9.0 ft heaUcool 9.0 ft heat/cool 4 Room dimensions 1.0 x 207.5 ft 1.0 x 60.8 ft 5 Room area 207.5 ft' 60.8 ft2 Ty Construction U-value Or HTM Area (ft) Load Area M2) Load number (BtuhA?-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V Block W all R-4.1 0.155 n 4.49 3.77 86 86 384 322 41 41 182 153 Double PaneA unn 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 11 Double PaneA unn 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 n 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 a 4.49 3.77 54 54 243 203 63 63 283 237 Double PaneA unn 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 a 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 s 4.49 3.77 126 126 566 475 41 41 182 153 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 s 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 w 4.49 3.77 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 28.57 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 18.59 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 w 0.00 0.00 0 0 0 0 0 0 0 0 Frame W all 2 x 6 R-1 0.066 - 0.00 0.00 0 0 0 0 0 0 0 0 D Solid Wood Core 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 C vented Metal Roof R- 0.032 0.93 1.37 208 208 193 284 61 61 56 83 C vented Metal Roof R- 0.032 0.93 1.69 0 0 0 0 0 00 0 F Slab on grade 0.582 16.88 0.00 208 30 498 0 61 16 270 0 6 c)AED excursion -7 -3 Envelope loss/gain 1884 1277 974 622 12 a) Infiltration 549 163 298 89 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1 0 Subtotal(lines 6 to 13) 2433 1441 1271 711 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2433 1441 1271 711 15 Duct loads 21% 300/6 500 431 21% 30-/ol 261 213 Total room load 2933 1871 1533 923 Air required(cfm) 137 87 72 43 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -ri- wrigFmtsoTrt® 2020-Oct-2921:27:45 . A -•w-w• Right-Suite®Universal 2019 19.0.21 RSU26566 Page10 rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces:E '� roCalcs@ Right-JO Worksheet Job: Brennan Residence �� we°rcmemnsingp-e �u� _ L n Date: Oct 29,2020 n By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAM 815254 1 Room name MTOILET M W IC 1 2 Exposed wall 10.5 ft 7.0 ft 3 Room height 9.0 ft heaUcool 9.0 ft heat/cool 4 Room dimensions 6.5 x 4.5 ft 6.5 x 7.0 ft 5 Room area 29.3 ft2 45.5 ft2 Ty Construction U-value Or HTM Area M2) Load Area M) Load number (BtuhA?-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V Block W all R-4.1 0.155 n 4.49 3.77 41 41 182 153 0 0 0 0 Double PaneA unn 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 11 Double PaneA unn 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 n 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 a 4.49 3.77 54 54 243 203 0 0 0 0 Double PaneA unn 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA urn 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 a 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 s 4.49 3.77 0 0 0 0 63 44 199 167 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 12.76 12.76 0 0 0 0 19 19 239 239 Double PaneA unn 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 s 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 w 4.49 3.77 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 28.57 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneA unn 0.440 w 12.76 18.59 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 w 0.00 0.00 0 0 0 0 0 0 0 0 Frame W all 2 x 6 R-1 0.066 - 0.00 0.00 0 0 0 0 0 0 0 0 D Solid Wood Core 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 C vented Metal Roof R- 0.032 0.93 1.37 29 29 27 40 46 46 42 62 C vented Metal Roof R- 0.032 0.93 1.69 0 0 0 0 0 0 0 0 F Slab on grade 0.582 16.88 0.00 29 11 177 0 46 7 118 0 6 c)AED excursion -2 -2 Envelope loss/gain 629 394 599 466 12 a) Infiltration 195 58 130 39 b) Room ventilation 0 0 1 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 824 452 729 504 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 824 452 729 504 15 Duct loads 21% 300/. 1701 135 21% 30%1 150 151 Total room load 994 587 879 655 Air required(cim) 47 27 41 30 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -ri- wrigFmtsoTrt® 2020-Oct-2921:27:45 . A -•w-w• Right-Suite®Universal 2019 19.0.21 RSU26566 Page11 rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces:E '� roCalcs@ Right-JO Worksheet Job: Brennan Residence �� we°rcmemnsingp-e �u� _ L n Date: Oct 29,2020 n By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 1 Room name M W IC 2 MASTER BEDROOM 2 Exposed wall 4.5 ft 35.5 ft 3 Room height 9.0 ft heat/cool 11.8 ft heat/cool 4 Room dimensions 1.0 x 58.3 ft 1.0 x 372.8 ft 5 Room area 58.3 ft2 372.8 ft2 Ty Construction U-value Or HTM Area W) Load Area M) Load number (BtuhA?-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V Block W all R-4.1 0.155 n 4.49 3.77 41 41 182 153 0 0 0 0 Double PaneAlUm 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 11 Double PaneAlUm 0.440 n 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 n 0.93 0.78 0 0 0 0 0 0 0 0 Block W all R-4.1 0.155 a 4.49 3.77 0 0 0 0 56 56 249 209 Double PaneAlUm 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlum 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlum 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlum 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 e 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 a 0.93 0.78 0 0 0 0 6 6 6 5 Block W all R-4.1 0.155 s 4.49 3.77 0 0 0 0 246 222 998 836 Double PaneAlUm 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 s 12.76 12.76 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 s 12.76 12.76 0 0 0 0 24 24 306 306 Double PaneAlUm 0.440 s 0.00 0.00 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 s 0.93 0.78 0 0 0 0 23 23 21 18 Block W all R-4.1 0.155 w 4.49 3.77 0 0 0 0 180 140 629 527 Double PaneAlUm 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 w 12.76 28.57 0 0 0 0 40 3 510 1143 Double PaneAlum 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 w 0.00 0.00 0 0 0 0 0 0 0 0 Double PaneAlUm 0.440 w 12.76 18.59 0 0 0 0 0 0 0 0 W Knee W all R-30 0.032 w 0.00 0.00 0 0 0 0 0 0 0 0 Frame W all 2 x 6 R-1 0.066 - 0.00 0.00 0 0 0 0 0 0 0 0 D Solid Wood Core 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 C vented Metal Roof R- 0.032 0.93 1.37 58 58 54 80 372 372 345 509 C vented Metal Roof R- 0.032 0.93 1.69 0 0 0 0 1 1 1 2 F Slab on grade 0.582 16.88 0.00 58 5 76 0 373 36 599 0 6 c)AED excursion -1 535 Envelope loss/gain 312 231 3665 4090 12 a) Infiltration 84 25 1055 314 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 396 256 4721 4404 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 396 256 4721 4404 15 Duct loads 21% 30%1 81 77 21% 30%1 971 1317 Total room load 477 333 5692 5722 Air required(cfm) 22 15 266 266 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -ri- wrigFmtsoTrt® 2020-Oct-2921:27:45 . A -•w-w• Right-Suite®Universal 2019 19.0.21 RSU26566 Page12 rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces:E Duct System Summary Job: Brennan Residence *-V o)Ca'CS® Date: Oct 29,2020 We are the missing piece' AHU_ y By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Finail:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 Project • • For: Brennan Residence 12094 NW Harbour Ridge Blvd,Palm City,FL 34990 Heating Cooling External static pressure 0.60 in H2O 0.60 in H2O Pressure losses 0.24 in H2O 0.24 in H2O Available static pressure 0.36 in H2O 0.36 in H2O Supply/return available pressure 0.203/0.157 in H2O 0.203/0.157 in H2O Lowest friction rate 0.066 in/100ft 0.066 in/100ft Actual air flow 1605 cfm 1605 cfm Total effective length(TEL) 545 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk ATRIUM c 1293 0 60 0.097 5.0 Ox 0 VIFx 34.5 175.0 st8 BATH 2 c 219 0 10 0.110 4.0 Ox 0 VIFx 20.0 165.0 st8 BATH 3 c 1174 0 54 0.066 4.0 Ox 0 VIFx 58.1 250.0 st8 BEDROOM 2 c 1435 0 66 0.079 5.0 Ox 0 VIFx 44.0 215.0 st8 BEDROOM 3 c 1977 0 92 0.152 6.0 Ox 0 VIFx 18.5 115.0 st8 DINING ROOM-A c 1311 0 61 0.148 5.0 Ox 0 VIFx 32.5 105.0 st11 DINING ROOM-B c 1311 0 61 0.148 5.0 Ox 0 VIFx 27.0 110.0 st11 FOYER c 2501 0 116 0.143 7.0 Ox 0 VIFx 36.9 105.0 st11 GREATROOM c 4222 0 196 0.084 9.0 Ox0 VIFx 36.5 205.0 st8 GREATROOM-A c 4222 0 196 0.071 9.0 Ox0 VIFx 52.1 235.0 st8 GREATROOM-B c 4222 0 196 0.081 9.0 Ox0 VIFx 45.0 205.0 st8 GREATROOM-C c 4222 0 196 0.074 9.0 Ox0 VIFx 46.5 230.0 st8 HALF BATH c 208 0 10 0.163 4.0 Ox 0 VIFx 9.5 115.0 st8 LAUNDRY c 1273 0 59 0.159 5.0 Ox 0 VIFx 13.0 115.0 st11 NEW PANTRY c 518 0 24 0.068 4.0 Ox 0 VIFx 52.0 245.0 st8 OPEN TO BELOW c 3992 0 185 0.124 9.0 Ox 0 VIFx 34.5 129.0 st8 WIC2 c 214 0 10 0.097 4.0 Ox0 VIFx 39.0 170.0 st8 WIC3 c 333 0 15 0.091 4.0 Ox0 VIFx 39.5 185.0 st8 wrightsoft- 2020-Oct-29 21:34:11 """y......, Right-Suite@ Universal 2019 19.0.21 RSU26566 Pagel ACCA ...rking Drawings\Brennan Residence Load Calcs.rup Cale=MJ8 Front Door faces: E Supply Trunk Detail • - Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st8 PeakAVF 0 1309 0.066 785 16.3 12 x 20 RectFbg st2 st2 PeakAVF 0 1605 0.066 917 19.4 14 x 18 RectFbg st11 PeakAVF 0 296 0.143 667 8.6 8 x 8 RectFbg st2 TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb1 Ox 0 0 577 237.3 0.066 539 14.0 Ox 0 VIFx rt3 rb4 Ox 0 0 131 115.5 0.136 489 7.0 Ox 0 VIFx rt3 rb3 Ox 0 0 117 224.3 0.070 336 8.0 Ox 0 VIFx rt3 rsb2 Ox 0 0 121 114.4 0.137 455 7.0 Ox 0 VIFx rt3 rb6 Ox 0 0 659 99.0 0.158 616 14.0 Ox 0 VIFx rt3 TableReturn Trunk Detail Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt3 PeakAVF 0 1605 0.066 657 16.6 16 x 22 RectFbg rt2 rt2 PeakAVF 0 1605 0.066 419 14.8 24 x 23 RectFbg wrightsoft- 2020-Oct-29 21:34:11 ....rw„......, Right-Suite@ Universal 2019 19.0.21 RSU26566 Page ACCP. ...rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces: E Duct System Summary Job: Brennan Residence *-V o)Ca'CS® Date: Oct 29,2020 We are the missing piece' AHU- 2 By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Finail:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 Project Information For: Brennan Residence 12094 NW Harbour Ridge Blvd,Palm City,FL 34990 Heating Cooling External static pressure 0.60 in H2O 0.60 in H2O Pressure losses 0.24 in H2O 0.24 in H2O Available static pressure 0.36 in H2O 0.36 in H2O Supply/return available pressure 0.224/0.136 in H2O 0.224/0.136 in H2O Lowest friction rate 0.151 in/100ft 0.151 in/100ft Actual air flow 804 cfm 804 cfm Total effective length(TEL) 239 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk LIVING ROOM c 3599 0 167 0.153 8.0 Ox 0 VIFx 36.9 110.0 st3 LIVING ROOM-A c 3599 0 167 0.165 8.0 Ox 0 VIFx 30.5 105.0 st3 M BATH c 936 0 44 0.174 4.0 Ox 0 VIFx 19.0 110.0 st5 M BATH-A c 936 0 44 0.164 4.0 Ox 0 VIFx 17.0 120.0 st5 •CLOS c 923 0 43 0.153 4.0 Ox 0 VIFx 26.2 120.0 st5 •TOILET c 587 0 27 0.151 4.0 Ox0 VIFx 23.6 125.0 st5 M WIC 1 c 655 0 30 0.165 4.0 Ox 0 VIFx 6.0 130.0 st5 MWIC2 c 333 0 15 0.159 4.0 Ox0 VIFx 11.0 130.0 st5 MASTER BEDROOM c 2861 0 133 0.198 7.0 Ox 0 VIFx 23.0 90.0 st3 MASTER BEDROOM-A c 2861 0 133 0.187 7.0 Ox 0 VIFx 15.0 105.0 st3 • • Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 PeakAVF 0 601 0.153 772 10.9 8 x 14 RectFbg st1 st5 PeakAVF 0 203 0.151 610 7.4 8 x 6 RectFbg st4 st4 PeakAVF 0 203 0.151 203 7.6 8 x 18 RectFbg st1 st1 PeakAVF 0 804 0.151 804 13.0 8 x 18 RectFbg wrightsoft- 2020-Oct-29 21:34:11 ,....rw„......, Right-Suite@ Universal 2019 19.0.21 RSU26566 Page ACCA ...rking Drawings\Brennan Residence Load Calcs.rup Cale=MJ8 Front Door faces: E TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb7 Ox 0 0 335 90.2 0.151 426 12.0 Ox 0 VIFx rt1 rb2 Ox 0 0 469 77.5 0.175 598 12.0 Ox 0 VIFx rt1 TableReturn Trunk Detail Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 PeakAVF 0 804 0.151 280 13.0 18 x 23 RectFbg wrightsoft- 2020-Oct-29 21:34:11 ,....rw„......, Right-Suite@ Universal 2019 19.0.21 RSU26566 Page ACCP. ...rking Drawings\Brennan Residence Load Calcs.rup Calc=MJ8 Front Door faces: E Static Pressure and Friction Rate Job: Brennan Residence *-V o)Ca'CS® Date: Oct 29,2020 We are the missing piece' AHU_ y By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Finail:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 Project • • For: Brennan Residence 12094 NW Harbour Ridge Blvd,Palm City,FL 34990 AvailablePressure Heating Cooling (in H2O) (in H2O) External static pressure 0.60 0.60 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.15 0.15 Humidifier 0 0 Balancing damper 0.03 0.03 Other device 0 0 Available static pressure 0.36 0.36 Total • Supply Return (ft) (ft) Measured length of run-out 23 21 Measured length of trunk 36 7 Equivalent length of fittings 250 210 Total length 308 237 Total effective length 545 Friction Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.066 OK 0.066 OK Return Ducts 0.066 OK 0.066 OK Fitting Equivalent LengthDetails Supply 4W=35,2B2=35, 11 G=5, 11 G=5,2B3=40,2B5=50,2B5=50,9L=20, 1 D=10:TotalEL=250 Return 60=10,6C5=115, 11 G=5, 11 G=5, 11 G=5,6C1=10, 10B=10,6CA=10,5A=40:TotalE L=210 wrightsoft- 2020-Oct-29 21:34:12 ""'Y......, Right-Suite@ Universal 2019 19.0.21 RSU26566 Page 1 ACCA ...rking Drawings\Brennan Residence Load Calcs.rup Cale=MJ8 Front Door faces: E Static Pressure and Friction Rate Job: Brennan Residence *-V o)Ca'CS® Date: Oct 29,2020 We are the missing piece' AHU- 2 By: Jayvee Layug ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Finail:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 Project • • For: Brennan Residence 12094 NW Harbour Ridge Blvd,Palm City,FL 34990 AvailablePressure Heating Cooling (in H2O) (in H2O) External static pressure 0.60 0.60 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.15 0.15 Humidifier 0 0 Balancing damper 0.03 0.03 Other device 0 0 Available static pressure 0.36 0.36 Total • Supply Return (ft) (ft) Measured length of run-out 13 13 Measured length of trunk 11 3 Equivalent length of fittings 125 75 Total length 149 90 Total effective length 239 Friction Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.151 OK 0.151 OK Return Ducts 0.151 OK 0.151 OK Fitting Equivalent LengthDetails Supply 4W=35,2B1=30, 11 G=5, 11 G=5,9L=20,9L=20, 1 D=10:TotalEL=125 Return 60=10,6C1=10, 11 G=5, 11 G=5, 11 G=5,5A=40:TotalE L=75 wrightsoft- 2020-Oct-29 21:34:12 ""'Y......, Right-Suite@ Universal 2019 19.0.21 RSU26566 Page ACCA ...rking Drawings\Brennan Residence Load Calcs.rup Cale=MJ8 Front Door faces: E