HomeMy WebLinkAbout11.5.20 Brennan Residence M Sheets Digitally signed by L
yTPG'OCa1cs0 Thomas V Platania 0
'We are the missing piece'
® CAC1815254 ProCalcs, LLC Date: 2020.10.29
11 :28:20 -04'00' °
14; C, FT@CaIcs
`` 'we are the missing piece'
Signature can only be verified and
PO Box 882032
validated with electronic copy of Port Saint Lucie, FL 34988
We are the missingiece documents. Phone: 772-882-5700
p
www.ProCalcs.Net
tom@procalcs.net
License CAC 1815254
HVAC DESIGN FOR
AEM & ASSOCIATES LLC
BRENNAN RESIDENCE
U � M
� ow
� ct -+-j
eneral N
eov-
Please note not all notes may apply.
a I .
ct
1 . CONTRACTOR SHALL PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM. ARE NOTED ON THE MECHANICAL PLANS.
2. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE. CAREFUL ATTENTION SHALL BE PAID TO PRECISE LOCATION AND 15. FOR EACH RETURN AIR GRILLE, PROVIDE 3M FILTRETE 1000 MICRO ALLERGEN PLEATED AIR FILTERS (3M, 800-49403552,
COORDINATION OF DIFFUSERS, REGISTERS, AND GRILLES WITH STRUCTURAL FRAMING AND ELECTRICAL FIXTURES AT www.filtrete.com, MERV RATING: 11 , PRESSURE DROP: .2 @ 300 FPM, OR APPROVED SUBSTITUTE). PRIOR TO INSTALLATION,
CEILING LOCATIONS. ELECTRICAL FIXTURES AT CEILING TAKE PRIORITY OVER DUCT LAYOUT. ELECTRICAL FIXTURES AT THE CONTRACTOR SHALL VERIFY THAT THE AIR VELOCITY NOICE ACROSS EACH RETURN AIR FILTER WILL BE LOW, BASED Q
CEILING ARE NOT TO BE MOVED FROM THEIR PROPOSED LOCATIONS. SEE THE REFLECTED CEILING PLANS, WHERE ON THE PRESSURE DROP FOR PROPOSED FILTER TYPE AND THE PROPOSED RETURN AIR GRILLE SIZE(S). ANY RETURN AIR N
AVAILABLE, FOR EXACT LOCATIONS OF CEILING FIXTURES. NO STRUCTURAL MEMBER SHALL BE CUT WITHOUT PERMISSION FILTER GRILLES THAT ARE REQUIRED TO BE RESIZED BY THE CONTRACTOR, ARE TO BE SIZED FOR FILTER SIZES THAT ARE
FROM STRUCTURAL ENGINEER. READILY AVAILABLE AT HOME SUPPLY STORES. CUSTOM SIZES ARE NOT PERMITTED.
3. THE CONTRACTOR SHALL OBTAIN, AT HIS EXPENSE, ALL NECESSARY FEES, PERMITS, AND TESTS. 16. ALL BATH, KITCHEN, AND DRYER EXHAUST(S) SHALL BE VENTED TO THE EXTERIOR.
4. ALL WORK SHALL COMPLY WITH APPLICABLE CODES, REGULATIONS, ORDINANCES AND REQUIREMENTS OF AUTHORITIES 17. ALL BATH EXHAUST FANS SHALL BE DUCTED WITH 4" R-FIN. SLOPE AND FULLY SUPPORT ALL BATHROOM EXHAUST DUCTS
HAVING JURISDICTION. NO CONTRACTOR SHALL BID UNLESS FAMILIAR WITH THESE CODES. ALL WORK SHALL BE TO AVOID ANY SNAGS IN THE DUCT AND TO ALLOW FOR PROPER DRAINAGE. TERMINATE AT SOFFIT WITH SCREENED
EXECUTED IN A WORKMANLIKE MANNER AND SHALL PRESENT A NEAT, PROFESSIONAL APPEARANCE WHEN COMPLETED. GRILLE, UNLESS OTHERWISE NOTED.
ALL MATERIALS AND EQUIPMENT SHALL BE NEW. STORE AND INSTALL MATERIALS AND EQUIPMENT IN ACCORDANCE WITH 18. PROVIDE BACKDRAFT DAMPERS FOR ALL EXHAUST FANS.
THE MANUFACTURER'S INSTRUCTIONS. 19. ALL EXHAUST AIR DUCTS SHALL BE GALVANIZED SHEET METAL CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE HVAC SYSTEM(S) TO BE INSTALLED (REFRIGERANT LINES, EQUIPMENT, ASHRAE AND SMACNA STANDARDS.D
DUCTWORK, GRILLES, ETC.). ADDITIONAL OFFSETS, TRANSITIONS, ETC. MAY BE REQUIRED TO PROVIDE A COMPLETE 20. TESTING, ADJUSTING, AND BALANCING: THE CONTRACTOR SHALL BALANCE THE AIRFLOW DISTRIBUTION SYSTEMS,
SYSTEM. NO ABRUPT TRANSITIONS SHALL BE PERMITTED. THE MECHANICAL WORK HEREIN INCLUDES COMPLETE INCLUDING SUB MAINS, BRANCHES, AND TERMINALS TO QUANTITIES INDICATED ON THE UPDATED MANUAL J LOAD No. Revision/Issue Date
SYSTEMS OF HEATING, AIR CONDITIONING (TEMPERATURE AND HUMIDITY CONTROL), VENTILATION, BATHROOM EXHAUST, ANALYSIS (FOR RESIDENTIAL PROPERTIES) AND MANUAL J (COMMERCIAL PROPERTIES).
KITCHEN EXHAUST, AND ALL DUCTWORK. THE CONTRACTOR SHALL PROVIDE EACH ELEMENT THEREOF, AS INDICATED 21 . PROVIDE DRAW-THROUGH CONDENSATE TRAP AT EACH UNIT CONDENSATE DRAIN. DEPTH SHALL BE AT LEAST 1-1/2 TIMES 1 Issue 10/29/2020
HEREIN, OR REASONABLY INFERRED (WHETHER OR NOT SPECIFICALLY CALLED FOR BY ITEM), REASONABLY NECESSARY TO THE TOTAL S.P DROP OF THE UNIT.
FACILITATE EACH SYSTEM'S FUNCTIONING AS INDICATED BY THE DESIGN AND EQUIPMENT SPECIFIED. CONTRACTOR SHALL 22. PROVIDE PROGRAMMABLE SERIES 7-DAY THERMOSTAT. PRIOR TO ORDERING THE THERMOSTAT, THE CONTRACTOR SHALL
VERIFY SPACE CONDITIONS PRIOR TO THE FABRICATION OR INSTALLATION OF ANY WORK. VERIFY THAT THE SPECIFIED THERMOSTAT WILL OPERATE PROPERLY WITH THE PROPOSED AIR CONDITIONING EQUIPMENT.
6. THE CONDENSING UNIT AND AIR HANDLING UNIT EQUIPMENT SHALL BE AS SPECIFIED OR ARCHITECT APPROVED IF A SUBSTITUTE IS REQUIRED, CONTRACTOR MUST SUBMIT PRODUCT INFORMATION TO ARCHITECT FOR PRODUCT
SUBSTITUTE. APPROVAL. COORDINATE THERMOSTAT LOCATION WITH FURNITURE/EQUIPMENT LAYOUTS, WINDOWS AND DOOR SWINGS.
7. PRIOR TO START OF THE HVAC WORK, THE CONTRACTOR SHALL SUBMIT, TO THE ARCHITECT, AN UPDATED MANUAL J LOAD THERMOSTAT MUST BE LOCATED AT 54" A.F.F. AND NOT LOCATED ON AN OUTSIDE WALL.
ANALYSIS, BASED ON THE FINAL CONTRACTOR DOCUMENTS AND ACTUAL MATERIALS AND PRODUCTS SELECTED (ie: 23. SUPPLY AND RETURN AIR GRILLES SHALL MAINTAIN A MINIMUM DISTANCE OF 3'-01, FROM CEILINGS FANS.
BUILDING ENVELOPE INSULATION, EXTERIOR DOOR GLAZING, AND ANY OTHER APPLICABLE FACTORS THAT WOULD AFFECT 24. ALL DUCT BRANCHES, PER ACCA MANUAL D, SHOULD INCLUDE DAMPERS FOR PROPER AIR FLOW AND BALANCING.
THE UPDATED MANUAL J LOAD ANALYSIS). THE SIZING OF THE ACTUAL HVAC SYSTEMS TO BE UTILIZED (REFRIGERANT 25. NO EQUIPMENT SHALL BE PURCHASED UNTIL REVIEW BY THE PROFESSIONAL OF RECORD, EVEN IF EQUIPMENT HAS BEEN
LINES, EQUIPMENT, DUCTWORK, GRILLES, ETC.) SHALL BE BASED ON THE UPDATED MANUAL J LOAD ANALYSIS. THE SPECIFIED. For:
CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR PROPERLY SIZING THE HVAC SYSTEM. 26. ANY VARIATION FROM THE DESIGN PRESENTED COULD AFFECT SYSTEM PERFORMANCE.
8. THE CONTRACTOR SHALL COORDINATE A "MECHANICAL WALK-THROUGH" MEETING, WHICH IS TO OCCUR PRIOR TO THE 27. EQUIPMENT SHALL BEAR A U.L. OR OTHER RECOGNIZED LABEL, NAMEPLATES, WIRING DIAGRAMS, AND ENERGY RATINGS, AEM Associates LLC
START OF THE MECHANICAL ROUGH-IN. THE PURPOSE FOR THIS MEETING IS TO ALLOW THE OWNER, ARCHITECT, AND AS APPLICABLE. 3 Ridgewood Circle
CONTRACTOR TO REVIEW AND COORDINATE FINAL DUCT AND AIR DEVICE LOCATIONS. THE MECHANICAL 28. CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND ACCESSORIES SO THAT IT IS READILY ACCESSIBLE FOR SERVICING, Jupiter, FL 33469
SUBCONTRACTOR'S FOREMAN IS TO ATTEND THIS MEETING AS WELL. TESTING, BALANCING AND REPLACEMENT. o
9. NO CHANGES TO THE HVAC PLANS OR NOTES SHALL BE PERMITTED WITHOUT PROCALCS, LLC. PRIOR APPROVAL. 29. CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE AGAINST DEFECTS INALL MATERIALS AND WORKMANSHIP FOR ONE o
10. REFRIGERANT PIPING SHALL BE TYPE "L" SOFT DRAN COPPER, ASTM B280, AND SHALL BE MILL CLEANED, DRIED AND (1) YEAR FROM ACCEPTANCE WITH FOUR ADDITIONAL YEARS OF WARRANTY ON COMPRESSORS. `y
CAPPED. INSULATE REFRIGERANT 1 SUCTION LINE WITH " WALL FOAMED PLASTIC INSULATION SLIPPED OVER TUBING AND 30. PRIOR TO ACCEPTANCE BY THE OWNER, THE SYSTEMS SHALL BE TESTED AND BALANCED BY A AABC OR NEBB CERTIFIED J
ALL JOINTS THOROUGHLY SEALED. PAINT REFRIGERANT PIPING 2 INSULATION WITH TWO (2) COATS OF ACRYLIC T&B CONTRACTOR EXPERIENCED WITH THIS SYSTEM. THE CONTRACTOR SHALL CERTIFY THE TESTING AND BALANCING y: Sheet
PROTECTIVE PAINT WHERE INSULATION IS EXPOSED TO WEATHER. WITHIN +/- 10% OF DESIGN CFMS AND PROVIDE BALANCE TEST SHEETS. Drawn B JQL
11 . ALL FIBERGLASS DUCTWORK SHALL BE 1-1/2" FIBROUS GLASS ANTI-MICROBIAL DUCTBOARD INSTALLED IN ACCORDANCE 31 . AIR BALANCE TO BE PERFORMED BY THE AIR CONDITIONING CONTRACTOR TO THE OWNER'S COMFORT. ALL SUPPLY AND U
WITH THE LATEST EDITION OF S.M.A.C.N.A. FIBROUS GLASS DUCT CONSTRUCTION STANDARDS. 1" FIBROUS GLASS RETURN DUCTWORK SHALL BE INSTALLED IN ACCORDANCE WITH SMACNA STANDARDS AND LOCAL BUILDING CODES. Checked By:
ANTI-MICROBIAL DUCTBOARD MAY BE USED IN THOSE LOCATIONS WHERE ALLOWED BY CODE. NO ABRUPT TRANSITIONS 32. PROVIDE ALL CONTROLS, STARTERS, CONTROL WIRING, DISCONNECTS, AND OTHER ELECTRICAL EQUIPMENT AS REQUIRED TP 1� /� 1
SHALL BE PERMITTED. PROVIDE AIR TURNING VEINS IN ALL 90 DEGREE RECTANGULAR DUCT ELBOWS. FOR A COMPLETE AND OPERATIONAL SYSTEM. MECHANICAL CONTRACTOR IS TO COORDINATE WITH OTHER Date: M_ 1 °'
12. FLEXIBLE DUCTWORK SHALL BE THERMAFLEX M-KA TYPE WITH 1-1/2" ONE-POUND DENSITY INSULATION AND VINYL VAPOR CONTRACTORS TO ENSURE THAT ALL ITEMS REQUIRED ARE INCLUDED IN 10/29/2020 0-
BARRIER OR ARCHITECT APPROVED SUBSTITUTE. NO ABRUPT TRANSITIONS SHALL BE PERMITTED. 33. COORDINATE ALL POWER AND CONTROL WIRING WITH ELECTRICIAN. Scale: U
13. DUCT SIZES SHOWN ARE INSIDE NET DIMENSIONS. As Shown 0
14. ALL AIR DEVICES SHALL BE MANUFACTURED BY TITUS, 250 SERIES, OR APPROVED SUBSTITUTE. COLOR TO BE APPROVED
BY THE PROFESSIONAL OF RECORD PRIOR TO PAINTING GRILLES BUT ASSUMED TO BE WHITE FOR BID/BUDGET PURPOSES.
SUPPLY AIR REGISTERS SHALL BE DOUBLE DEFLECTION TYPE WITH OPPOSED BLADE DAMPERS. ALL SIZES AND PATTERNS
� 00 000 000 � 0
N
EXISTING MECHANICAL NOTES:
a�
U
GRILLE SIZES ARE BASED ON EXISTING BAT 3
CONDITION. SHOULD THERE BE ANY
DIFFERENCE, IT IS RECOMMENDED TO FOLLOW NEW °
SIZES SHOWN IN MECHANICAL DRAWINGS FOR GREAT 12 x 12 � Cal
PANTRY 0 CS
BETTER AIR DISTRIBUTION. ROOM 196 cfm O 1 ! •' 'We are the missing piece'
12 x 12 T T 9„ ` 9
996 cfm � � � 8 x 4 54 fm o PO Box 882032
T 24 cfm 4„
4„ Port Saint Lucie, FL 34988
a Phone: 772-882-5700
can Signature only be verified and www.ProCalcs.Net
g y tom@procalcs.net
10 x 10
validated with electronic copy of License CAC1815254
Z12X
12 56 cfm documents.
0 12x12 ,� 96cfm BEDROOM 2
996 cfm 11 9
0 , Dw
0 El WF±11 GENERAL NOTES:
z 1 . All supply ducts are designed per ACCA Manual D. !�
2. All supply branches are designed according to ACCA Manual D for r
KITCHEN the highest CFM's required Heating or Cooling, for the room load
12 x 12 per ACCA Manual J.
10 x 10 x 4 131 cfm 3. It is the installing HVAC Contractor's responsibility to install air
60 cfm 8 „ volume dampers to adjust appropriate air flow accordingly.
5 OVEN 7 � � Q
T 10 x 10 T II 10 cfm 4. Field coordinate all grille locations with other trades prior to
167 cfm
11
MICRO REF installation to maintain proper clearances required by applicable V
8" 01^1 W.I.C. codes.
LIVING (D 1 20 x 20 W.I.C.
ROOM F M
577 cfm
10 x 10 T 14" T g x 4 KEY NOTES: O L� 1
133 cfm U 15 cfm 1�1
7" 8 x 4 12 x 12 411 1 . 60 cfm minimum Bathroom exhaust an, 4 vent to outside.
T
117 cfm 2. Kitchen hood vent to be sized per manufacturer's instruction. Vent 40 cfm T 811 to outside.
11 3. 62 cfm minimum Bathroom exhaust fan, 4" vent to outside. ;-4
M• T 10 x 10 9" SUPPLY a 10 x 10 4. 50 cfm minimum Bathroom exhaust fan, 4" vent to outside. ct J--.)
BEDROOM 167 cfm TO ATRIUM BATH 2 92 cfm 5. Dryer vent to exterior, 4" vent to outside. ' rmm�
y 8" ABOVE o 6" 6. 100 cfm minimum Bathroom exhaust fan, 6" vent to outside.
y N
-> F 16x16 8 x 8 8 x 8 1/2 tAIr-i
335 cfm
12" 61 cfm 61 cfm 8 x 4
�5" 5" 10 cfm M
T `L_ 411
co
00 y FOYER 20 x 24 X
10 x 10 12 x 12 1 659 cfm N DEN/BEDROOM 3
133 cfm g x g T 121 cfm
14" a
F y
AHU - 1 N
7" �16 cfm DINsiv� 18 u 14 IN ATTIC) 23 x 24
2
8 x 8 T ( r�
CU-1 T ROOM 59 cfm F 18 x 6
8 x 8 5" (Transfer)
18x18 AHU - 2
2 nos. Legend
469 cfm 18 x 8 (IN ATTIC) 23 x 18 ------------------------------- 5
1211 LAI.. ND R Please note not all symbols may apply.
CU-2 W.I.t T T
8 x 4 T 185 cfm N.I.C. F F Supply grille
30 cfm
3 4„ No. Revision/Issue Date
ao - 1 Issue 10/29/2VERIFY X
02
OCA ION CO 8 x 8 -� Sidewall supply grille
ON SITE o 44 cfm
0 y y
411 ��F ��F Return grille
M. BA „i T T
OPEN TO
O BELOW Riser duct up/down
O 12x8
8 x s GARAGE
44 Isi
cfm 8 x 4 911 cfm (D Thermostat (AH-Zone) For:
27 cfm 1� 7
411 O Exhaust fan
AEM Associates LLC
y / Kitchen range hood exhaust fan
3 Ridgewood Circle
43 cfm L a 12 x 12 Grill Size Jupiter, FL 33469
4" 148 cfm Grill CFM N
CL PROPOSED ATRIUM PLAN 8" Branch Duct Size N
U
J
J
Condensing unit Drawn By: Sheet
JQL
U
Checked By: °
TP a
W Date: m-2 .7
7
First Floor and Atrium HVAC Plan 1 oi29i2o2o �@
S N Scale: As Shown
1/4"
E
N
L
Q)
U
t� o
'We are the missing piece'
PO Box 882032
Port Saint Lucie, FL 34988
NOTES:
1.ALLOW SUFFICIENT SPACE BELOW DRAIN (a)THIS DIMENSION IN INCHES MUST BE Pone. 772-882-5700
TO THEFAN
CONDENSING UNIT BOLTED TO PAN FOR TRAP. (NEGATIVE)EQUAL
STATIC PM EUM SSURE ININICOHES WC Signature can only be verified and www.ProCalcs.Net
CONCRETE PAD TO WITHSTAND ___ 2. PITCH DRAIN FOR PROPER RUNOFF. (WITH DIRTY FILTERS, COILS, AND MAXIMUM '
HURRICANE FORCE WINDS. AS 3. MANUALLY PRIME FILL TRAP BEFORE AIR FLOW)+ 1"W.C. validated with electronic copy of tom@procalcs.net
PER FBCM 301.12 START-UP TO FORM INITIAL DRAIN SEAL.
4. SUPPORT LENGTHY DRAIN LINES TO
PREVENT SAG AND CONDENSATE OVERFLOW. (b)THIS DIMENSION IN INCHES MUST BE documents.
License CAC 1815254
EQUAL TO MIN. 1/2 OF THE (a)ABOVE.
� 16 GA. HURRICANE
j STRAP THIS STANDARD DETAIL (c) EQUAL (a)+ (b)+ PIPE DIA. + INSULATION.
MUST BE REVIEWED AND
COND. UNIT 1/4"X 2"SELF-DRILLING SITE ADAPTED BY
SHEET METAL SCREW CONTRACTOR PRIOR TO USE LA TRAP SEAL SHALL BE 2" MIN. ON UNITS EQUIPMENT SCHEDULE
3/8" X 2 1/2" QUICK-BOLT FOR FINAL EQUIPMENT. LARGER THAN 3 TONS SHALL B 3. MIN. PER
EXPANSION ANCHOR. F.B.C. -4606.7 WHERE APPLICABLE.
CU NUMBER CU-1 CU-2
ISOMODE PAD (TYPICAL OF 4 ONE PER ` (e)TRAP SEAL SHALL BE 2" MIN.TO 4" MAX. NOMINAL TONNAGE 4.0 tons 2.0 ton s
CORNER OF UNIT) PER S.B.C.C.I. -1002.4 WHERE APPLICABLE. ( ) ( )
° A/C UNIT CLEANOUT ~ MODEL RAND-048JAZ RAND-024JAZ
(TYPICAL) Z SEER/EER/HSPF 13.50/12.10 14.00/12.05
4"CONC. PAD ° PITCH VENT LINE PERFORATED CAP. 1/2" 0
ABOVE BOTTOM OF DRAIN PAN O CAPACITY TOTAL/SENS. 43,644 / 34,489 22,344 / 17,298
4" CONCRETE SLAB. TOP OF ISOMODE PAD (TYPICAL) DRAIN PAN PITCH Z STAGES Single Single
SLAB. (a) Z RLA - LRA 20.2 - 137.0 10.4 - 54.0
(�) Z Voltage 208/230 460 208/230 460 Q
DRAIN PIPE TO (b) 0
-- Phase Single Three Single Three
LU
NOTE: MATCH DRAIN Z
CONDENSING UNITS TO BE INSTALLED ABOVE FLOOD LEVEL CRITERIA. OUTLET SIZE. O MCA/MOP 27.0/45.0 11 .0/15.0 V
v WEIGHT 225 145
CONDENSING UNIT MOUNTING DETAIL NITS DRAW THROUGH UNIT CONDENSATE TRAP NTs AHU NUMBER AIII AIII
4�
AHU-MODEL RBHP-24J11SHD RBHP-17J06SHD � (�
STATIC PRESSURE 0.60 0.60
REFRIGERANT R-22 R-22
LOCATION ATTIC ATTIC Q� 0
CFM 1605 804
FAN MOTOR HP - FLA 3/4 - 5.8 1/3 - 3.3
HANGER (TYP.) ELECTRIC HEATER Voltage 208 X1 230 X1 460 208 X1 230 X1 460
Phase Single X Three Single Three
kW 7.5 (208V) - 10.0 (230V) 3.7 (208V) - 4.9 (230V)
Model Number RBHP-24J11SH* RBHP-17JO6SH* v
1 1/2" MIN. 2" MIN. SUPPORT STRAP J MCA/MOP 40.3/60 208V - 45.9/60 230V 19.8/25 208V - 22.4/30 23OV ••��
STRAP HANGER�i 18" MAX. FROM DEVICE AND G
FLEXIBLE DUCT SAG Z DIMENSIONS H x W x D 35 x 24-1/2 x 22-1/2 35 x 17-1/2 x 22-1/2 Q�
NOT TO EXCEED 1/2" 5'-0" ON CENTER Q WEIGHT 134 99
PER FOOT MAX.---,,,,., = REF LINES SIZES 3/8, 1-1/8 3/8, 1-1/8 M
DUCT ) MAXIMUM ALLOWABLE Q NOTES: RHEEM AHRI #: N/A AHRI #: N/A
LENGTH OF FLEX. DUCT
8'_0„
— — — — FLEX DUCIBEND
^O,
FASTENERS MAY BE ` V
OMITTED IF HANGER GRILLE SCHEDULE
LOOPS UNDER DUCT. Titus Series 250
FASTENER MAINTAIN RADIUS OFTO NOT LESS THAN Size Velocity (FPM) 400 500
RIGID RECTANGULAR DUCT DUCT DIAMETER FLEX DUCT CFM 50 60
4-way 12 14
DUCTWORK SUPPORT DETAILS 8 x 4 Throw (ft) 3-way 13 15
NITS 14 17
1-way 17 21
Date
NOTE:PROVIDE CABLE CONTROL DAMPER FOR HARD CEILING AREAS. CFM 140 N/A No. Revision/Issue
Throw (ft) 4-Way 15 N/A
LOCKING QUADRANT 8 x 8 3-way 15 N/A 1 Issue 10/29/2020
TO BE EXPOSED GALV.STEEL ROD OR
2-way 13 N/A
STRAP SUPPORTS PER
SMACNA STANDARDS 1-way 17 N/A
FLEXIBLE DUCT WITH SIDE TAKE-OFF FITTING
INSULATION& WITH DAMPER,BELL MOUTHVAPOR BARRIER CFM 250 310
OR SHOETAP TYPE(SEE NOTE)
4-way 17 N/A
MAIN SUPPLY AIR EYE BOLT THRU 10 x 10 3-way 18 N/A
TIE TO DUCT,SEE PLANS FOR CLAMP WRAPPED Throw (ft)
STRUCTURAL TYPE AND I SULATION ITHRU
AROUND TRUSS 2-way 20 N/A
SUPPORTS
— — — 1-way 20 N/A
2"WIDE METAL BAND \ \ TRUSS EYE CFM 350 N/A
SUPPORT CLAMP WRAPPED
� � I AROUND TRUSS 1/2" RODS 4-way 19 N/A For:
1/2" RODS (TYP. OF 4) 12 x 12 3-way 20 N/A
(TYP. OF 4) Throw (ft) AEM Associates LLC
Ridgewood Circle
I 1-1/2'X 1-1/2'X 1/E' GALV. 1-Way 22 N/A 2-way 22 N/A 3 Rid g
SQUARE TO ANGLE OR STRAP PER SMACNA
ROUND SUPPLY AHU RETURN Jupiter, FL 33469
ADAPTER CONNECT INNER DUCT WITH DRAWBAND AIR DUCT AIR DUCT O
AND SEAL WITH TAPE/MASTIC OUTERDUCT CV
AT NECK CONNECTION O
I I N
PROVIDE THERMAL INSULATION BLANKET U.
J
IF INSTALLED IN UNCONDITIONED SPACE AHU SHALL HAVE A CONDENSATE FLOAT UNIT STRUTS (2) J
SWITCH TO CONTROL OVERFLOW THAT WILL 3/4"CONDENSATE LINE Drawn By: Sheet
AUTOMATICALLY SHUT DOWN THE AC SYSTEM AUXILIARY DRAIN PAN TO P-TRAP JQL
SCEILING
EDT SYSTEM LOUVERED FACE CEILING DIFFUSER THE DEVICE SHALL BE ATTACHED TO THE SECURED TO UNISTRUT ()
SECONDARY DRAIN OUTLET ON THE AHU STAINLESS STEEL
Checked By:
L
TYPICAL DIFFUSER DETAIL NITS AIR HANGING UNIT INSTALLATION DETAILS NTs TP M-3
Date.
10/29/2020 a
0
Scale: v
As Shown