Loading...
HomeMy WebLinkAboutProduct approval, metal I 9 Fw- BCIS Home Log In I User Registration Hot Topics Submit Surcharge Stats&Facts ( Publications Contact Us ( BCIS Site Map Links I� Search f db a {� l, Product Approval {,(ram L,j USER:Public User Cj: r r.�c�wYu�EtiN '1,1� Product Approval Menu''>Product or Application Search>Application List>Application Detail --7 ®aI: FL# FL27499-R1 Application Type Revision Code Version 2017 Application Status Approved I I Comments I Archived _ i Product Manufacturer F3201 Metals Address/Phone/Email ominica Terace 34997 -8030 amicmetal.net I Authorized Signature amicmetal.net Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email I Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ( Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Scott Wolters Evaluation Report Florida License PE-62354 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 12/31/2026 Validated By Lucas A.Turner, P.E., MBA j t_j Validation Checklist-Hardcopy Received Certificate of Independence FL27499 R1 COI Dyn COI.pdf I Referenced Standard and Year(of Standard) Standard Year - i TAS 100 1995 i TAS 110 2003 TAS 125 2003 Equivalence of Product Standards Certified By �Q Sections from the Code file COPS I I I Product Approval Method Method 1 Option D Date Submitted I 02/22/2019 Date Validated i 08/29/2019 Date Pending FBC Approval 08/30/2019 Date Approved 10/15/2019 Date Revised j 10/24/2020 Summary of Products FL# Model,Number or Name Description 27499.1 DM Class 1000 1" Nailstrip 26 Ga.galvalume coated steel roof panel, 16"wide,with 1" snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 Rl II NSSI6HZ.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Please see Eva[report for Limits of Use. FL27499 Rl AE DM Evall.pdf Created by Independent Third Party: Yes 27499.2 DM Class 1000 1" Nailstrip, .032"Aluminum roof panel, 16"wide,with 1"snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 Rl II NSAI6HZ.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Eval2.pdf Created by Independent Third Party:Yes 27499.3 DM Class 1050 1 1/2" Nailstrip .032"Aluminum Roof Panel, 19"Wide,with 1 1/2"snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 Rl II NSAI9HZ.pdf Approved for:use outside HVHZ:Yes Verified By: Scott Wolters,P.E. FLPE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 Rl AE DM Eval3.pdf Created by Independent Third Party:Yes 27499.4 DM Class 1050 1 1/2" Nailstrip 24 Ga.Galvalume coated steel roof panel, 19"wide,with 1 ...,.�— 1/2"snap fit seams Limits of Use Installation Instructions Approved for,use in HVHZ:Yes FL27499 Rl II NSSI9HZ.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters, P.E. FLPE#62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Pleaseee Eval report for Limits of Use. FL27499 Rl AE DM Eval4.pdf Created by Independent Third Party:Yes i 27499.5 DM Class 1500 1 1/2"Mechanical .032"Aluminum roof panel, 20"wide,with 1 1/2"standing Seam seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 Rl II 15MSA20HZ.pdf j Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 Rl AE DM EvalS.pdf Created by Independent Third Party: Yes 27499.E DM Class 1500 1 1/2" Mechanical 16 oz.Copper roof panel, 16"wide,with 1 1/2"standing Seam seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 RI II 15MSCHZ.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 Rl AE DM Eva 16.pdf Created by Independent Third Party:Yes i 27499.7 DM Class 1500 1 1/2"Mechanical 26 Ga.galvalume coated steel roof panel, 16"wide,iwith 1 1/2" Seam standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 RI II 15MSS1626HZ.pdf I WOLTERS ENGINEERING ENGINEERING, DRAFTING,CONSULTING 15211 97th Road N West Palm Beach,FL 33412 Ph/Fx:(561)225-1982 I PRODUCT EVALUATION (FOR HVHZ APPROVED PRODUCT) PRODUCT: DM CLASS 1050 24 GAUGE GALVALUME 1%" NAILSTRIP 19"WIDE ROOF PANEL (FLPA#27499.4) MANUFACTURER: DYNAMIC METALS, LLC 340 PIKE ROAD WEST PALM BEACH, FL 33411 To all concerned, The DM Class 1050 Series 24 Gauge Galvalume 1W Nailstrip 19"Wide Roof Panel, manufactured by Dynamic Metals LLC, is a non-structural Galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the requirements of Sections 1507.4 and 1518.9 of the 6th Edition (2017) Florida Building Code. The panel , has been tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.96-450-44 and G3443.17-450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-02-01 and VLS-005-02-01. Technical Documentation: 1. Drawing "NSS19-HZ"dated 8/15/19, signed and sealed by Scott Wolters, PE. 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE. 3, Supplemental Calculations to support"NSS19-HZ"drawing, signed and sealed by Scott Wolters, PE. . I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. i Limitations: This panel is approved for use inside and outside of the HVHZ. i Overall Limitations: Maximum Panel Width: 19" (nominal) Fastener Spacing across panel: 19" (at Nailstrip) (Panels overlap with male/female snap fit) Min. Slope: HVHZ: 2712" Non-HVHZ: Y2'/12" (Lap Sealant Req'd —See Chart) 5P�1 0&0% IN IMPACT t?1�515TAW CLIPrAINWALL5,5f0PffF0NT5, & WINPOW5 Field Perimeter&Corner Installation Installation Max. Design Pressure: -112.5 psf -112.5 psf Fastener Spacing: 3" From Ends, 6" Max. O.C. 3" From Ends, 6" Max. O.C. Min Panel Fasteners: #10x1" Panclip Fasteners #10x1" Panclip Fasteners Panel Sealant: Continuous bead of Geocel 2300 Continuous bead of Geocel 2300 or 2320 on both sides of seam or 2320 on both sides of seam I Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well! as the location of the fire barrier within the assembly. (See note#2 below) Note: Outside of the HVHZ, 1"round plastic caps may be used to prevent galvanic reactions. I Underlayment: Minimum ASTM D 226 Type II with 4"overlaps and 6"end-laps, anchored with 12 Ga. x 1 W galvanized roof nails with 32 Ga. Tin caps spaced 6" O.C. in rows at the perimeter, at overlaps, and two intermediate rows staggered and spaced 12"O.C. (or) Any underlayment with a valid FLPA or Miami-Dade NOA Note: Outside of the HVHZ, 1"round plastic caps may be used to prevent galvanic reactions. i i Minimum Substrate: '/2' (15/32" min)4-ply CDX Plywood, nailed to 2x rafters spaced 24" max. O.C. with 8d ring-shank nails spaced 4" O.C. Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. 4. Rational analysis, provided by a Florida licensed Architect/Engineer per FAS 61 G20.3.005(e), may be used for project specific approval by I the local authorities having jurisdiction. 5. All panels shall be permanently labeled with the manfacturer's name and/or logo, and the following statement, "Dynamic Metals FL#27499.4, DM Class 1050". 5FE CKIZING IN IMPACT FF515TAW CUpTAINWALL5, 5forffroNf5, & WINI70W5 I Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per approval of 3rd party QA provider, to the dimensions shown on Drawing NSS19-HZ: SSQ-6800617 SSQ-5150216 SSQ-6810617 SSQ-6690517 SSQ-4560615 SSQ-8681118 5VC-0490718 5VC-0360516 5VC-0521218 Re-Roofing: The DM Class 1050 Series .24 Ga. Galvalume 1'/z"Nailstrip 19"Wide Roof Panel may be installed over a single layer of existing asphalt shingles, provide the existing roof meets the requirements of Section 1521 (HVHZ)or Section 1511 (outside of HVHZ)of thel Florida Building Code. If you have any questions or need more information concerning this approval please contact me. i i ,A`1?4L91Ft11?frr� Thank you, ♦,♦���0-v .WO/_T r,1� ♦ C IV �p No 62354 p Scott Wolters ®-o FL PE# 62354 +�'•• STATE 0 F 0 r �, AUG S �♦ i j j I i j i i I i 5FEC1' ,RING IN IMF FT515TANT CWTAIN AU5, 5TOFTFFONT5, & WINPON5 f 1 ryry'w _ P DID CLASS 1050 1 1/2" NAILSTRIP 24 CA® GALVALUME ROOF PANEL, s 19" WIDE (HVHZ) ----- - - - --- 19"Coverage yyy tL CO- Wood Deck x n Integral Snap Lock 2 � / tea, ` � ry Z_ fV V #lo X 1" Q e a Pancake-Head Screw I ' b 3 LU See Eval Report for Fastener Spacing u �o a �W Q 19"Coverage x Geocell 2300 or � �W --t— 2320 Sealant m S 4 Panel Profile w s s- z -- --- - - -- s/-Z-