HomeMy WebLinkAboutAPPROVED Attic Fan Professional Regulation .
BM Home I Login I User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff Boo Site Map E Links Search,i•
ba
OUSER.'Pubhe
Product Approval User
Product Aparoval Menu>Product or Application Search>Application List>Application petal]
® FL# FL13339-R6
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived []
Product Manufacturer Attic Breeze
Address/Phone/Email 1370 FM 116
Gatesville,TX 76528
(254)865-9999
travis.hipp@atticbreeze.net
Authorized Signature James Buckner
jimmy@cbuckinc.net
Technical Representative Travis Hipp
Address/Phone/Email 1370 FM 116
Gatesville,TX 76528
(877)288-4234
travis.hipp@atticbreeze.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
C1 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed James L.Buckner,P.E.@ CBUCK Engineering
the Evaluation Report
Florida License PE-31242
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 12/01/2029
Validated By Michael John Werner,P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence FL13339 R6 COI COI CertOf Indeo James BUCkner.P.E.sc.PDF
Referenced Standard and Year(of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
1708.2
Product Approval Method Method 2 Option B
Date Submitted 01/05/2018
Date Validated 01/05/2018
Date Pending FBC Approval O1/10/2018
Date Approved 04/10/2018
Summary of Products
FL# Model,Number or Name Description
13339.1 OS_Solar Attic Fan Models AB-201A,AB-202A,AB-251A,AB-252A,AB-2022A,
AB-3022A&AB-4022A.Self-flashing,solar powered fan
units,with solar panel directly attached to fan unit
shroud/dome
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL13339 R6 II 1-7 Attic Breeze-SPAF Panel Direct to Flush
Approved for use outside HVHZ:Yes Mount Unit EvalReportt.pdf
Impact Resistant:No Verified By:James L. Buckner, P.E. @ CBUCK,Inc.P.E.
Design Pressure:+115/-115 #31242
other: Refer to evaluation report for limitations and Created by Independent Third Party:Yes
conditions of use. Refer to manufacturer's installation Evaluation Reports
instructions as a supplemental guide. FL13339 R6 AE 1-7 Attic Breeze-SPAF Panel Direct to
Flush Mount Unit EvalReoort.pdf
Created by Independent Third Party:Yes
13339.2 02_Solar Attic Fan Models AB-201D,AB-202D,AB-251D,AB-252D,AB-401,AB-
402,AB-2022D,AB-3022D&AB-4022D.Self-flashing,solar
powered fan units,with solar panel(s)remotely attached
from fan unit,using low profile mounting brackets
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL13339 R6 II 2 7 Attic Breeze-SPAF Panel Remote to Low
Approved for use outside HVHZ:Yes Profile EvalReoort.oddf
Impact Resistant.No Verified By: James L. Buckner,P.E. @ CBUCK,Inc.P.E.
Design Pressure:+115/-115 #31242
Other:Refer to evaluation report for limitations and Created by Independent Third Party:Yes
conditions of use.Refer to manufacturer's Installation Evaluation Reports
Instructions as a supplemental guide. FL13339 R6 AE 2-7 Attic Breeze-SPAF Panel Remote to
Low Profile EvalReport.odf
Created by Independent Third Party;Yes
13339.3 03_Solar Attic Fan Models AB-201D,AB-202D,AB-251D,AB-252D,AB-401,AB-
402,AB-2022D,AB-3022D&AB-4022D. Self-flashing,solar
powered fan units,with solar panel(s)remotely attached
from fan unit,using universal mounting bracket
Limits of Use Installation Instructions
Approved for use in HVHZ:No Fi 13339 R6 II 3 7 Attic Breeze-SPAF Panel Remote
Approved for use outside HVHZ:Yes Inclined EvalReport.odf
Impact Resistant:No Verified By: James L.Buckner,P.E. @ CBUCK,Inc.P.E.
Design Pressure: +115/-115 #31242
Other:Refer to evaluation report for limitations and Created by Independent Third Party:Yes
conditions of use.Refer to manufacturer's installation Evaluation Reports
instructions as a supplemental guide. FL13339 R6 AE 3-7 Attic Breeze-SPAF Panel Remote
Inclined EvalReoort.odf
Created by Independent Third Party:Yes
13339.4 04_Solar Attic Fan Models AB-601,AB-602&AB-6022D.Self-flashing,solar
powered fan units,with solar panel remotely attached from
fan unit,using low profile mounting brackets
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL13339 R6 II 4-7 Attic Breeze-SPAF Panel Remote to Low
Approved for use outside HVHZ:Yes Profile EvalReoort.pdf
Impact Resistant:No Verified By:James L. Buckner,P.E. @ CBUCK,Inc.P.E.
Design Pressure:+115/-115 #31242
Other:Refer to evaluation report for limitations and Created by Independent Third Party:Yes
conditions of use.Refer to manufacturer's installation. Evaluation Reports
instructions as a supplemental guide. FL13339 3339 R6 AE 4-7 Attic Breeze-SPAF Panel Remote to
Low Profile EvalReoort.odf
Created by Independent Third Party:Yes
13339.5 05_Solar Attic Fan Models AB-601,AB-602&AB-6022D.Self-flashing,solar
powered fan units,with solar panel remotely attached from
fan unit,using universal mounting brackets
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL13339 R6 II 5-7 Attic Breeze-SPAF Panel Remote
Approved for use outside HVHZ:Yes Inclined EyaIReDort.Ddf
Impact Resistant:No Verified By:James L. Buckner,P.E. @ CBUCK,Inc..P.E.
Design Pressure:+115/-115 #31242
Other:Refer to evaluation report for limitations and Created by Independent Third Party:Yes
conditions of use.Refer to manufacturer's installation Evaluation Reports
instructions as a supplemental guide. FL13339 R6 AE 5-7 Attic Breeze-SPAF Panel Remote
Inclined EvalReoort.odf
Created by Independent Third Party; Yes
13339.6 06_Cardinal Ventilation Models CV-2000&CV-3000.Self-flashing,circular shaped
solar powered fan units,with solar panel directly attached to
fan unit hood/dome
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL13339 R6 iI 6-7 AS-Cardinal SPAF Panel Direct to Flush
Approved for use outside HVHZ:Yes Mount Unit EvalReoort.Ddf
Impact Resistant:No Verified By:James L. Buckner,P.E.@ CBUCK,Inc.P.E.
Design Pressure:+115/-115 #31242
Other:Refer to evaluation report for limitations and Created by Independent Third Party:Yes
conditions of use.Refer to manufacturer's installation Evaluation Reports
instructions as a supplemental guide. FL113339 R6 AE 6-7 AB-Cardinal SPAF Panel Direct to
Flush Mount Unit EvalReport.odf
Created by Independent Third Party:Yes
13339.7 Curb Mount Series Curb Profile vent fan base for attachment to roof curbs
Limits of Use Installation Instructions
Approved for use in HVHZ:No FI 13339 R6 II 7-7 Curb-SPA-CM-ER W 10 odf
Approved for use outside HVHZ:Yes Verified By:James L Buckner,P.E.@CBUCK,Inc P.E.#
Impact Resistant:No 31242
Design Pressure:+115/-115 Created by Independent Third Party:Yes
Other:Refer to evaluation report for limitations and Evaluation Reports
conditions of use. FI t3339 R6 AE 7-7 Curb-SPA-CM-ER W 10 odf
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stane Roatl Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.;please
click here.
Product Approval Accepts:
Credit Card
Safe
CBUCK Engineerinq
Specica tLj Structural Eriglr�erinq CBUCK,Inc.Certificate of Authorization#8064
Evaluation Report
"Solar Attic Fans"
Self-Flashing Series
with Low Profile Remote Mounted Solar Panel
20 Watts;30 WaM & 40 Watts Solar Panels
Manufacturer
Attic Breeze, LLC.
1370 F M 116
Gatesville, Texas 76528
(877)288-4234
for
Florida Product Approval
# FL 13339.2 R6
Florida Building Code 6th Edition (2017)
Per Rule 61G20-3
Method: 2- B
Category: Roofing
Sub - Category: Roofing Accessories that are an Integral
Part of the Roofing System
Product Names: Solar Attic Fans
Product Description: Self-Flashing Series
with Low Profile Remote Mounted Solar Panel
Facsimile of digital copy signed by
James L.Buckner,P.E.
Prepared by: Electronically signed and sealed documents sh
James L. Buckner, P.E.,SECB comply with the provisions of FAC Rule 61G15-:
Florida Professional Engineer#31242
Florida Evaluation ANE ID: 1916 �� ��cenlsF'•-cc,P
Report No. 18-101-SPAF-RemLP-S4W-ER =*' No31242 "
Date: 1/4/18 --o
Luz
Contents: =�i(�'. STATE OF
Evaluation Report Pages 1—8 Fs'' •F�oR...
/O N A\�\\\\
CBUCK,Inc. - Palm Beach County,Florida 2018.01.0415.00:37-05'00'
Phone:(561)491-9927•Email:cbuck@cbuckinc.net•Website:www.cbuckinc.net
FL#: FL 13339.2 R6.
//''''''�� Date: 1/4/18
(. BUCK Engineerinq Report No.: 2 of 081-SPAF-RemLP-S4W-ER
SpectaH-L j Structural Engtneertnq CBUCK,Inc.Certificate of Authorization#8064
Manufacturer: Attic Breeze,LLC.
Product Name: Solar Attic Fans
Product Category: Roofing
Product Sub-Category Roofing Accessories that are an Integral part of the Roofing System
Compliance Method: State Product Approval Rule 61G20-3.005 (2)(b)
Product Description: The Solar Attic Fan is a roof mounted system powered by one or two solar panels.
The unit consists of a 14 inch diameter fan,enclosed in a-self-flashing fan house base
vent, with corrosion resistant zincalume alloy steel housing, including a thermal
switch, and a rodent guard.solar panel is remotely attached from the fan house unit
shroud/dome.
Product Assembly as Self-flashing solar attic fan with low profile remote mounted solar panel
Evaluated: - Fan house base unit component mechanically attached to deck
Solar panel remotely attached to four (4) low profile mounting brackets with
machine bolts
- Low profile mounting brackets attached to roof deck with screws
Model Numbers: No./Designation No.of Solar Panel
AB-201D 1 Solar Panel
AB-202D 1 Solar Panel
AB-251D 1 Solar Panel
AB-252D 1 Solar Panel
AB-401 2 Solar Panels
AB-402 2 Solar Panels
AB-2022D 1 Solar Panel
�t AB_ 3022D , 1 Solar Panel
AB-4022D 1 Solar Panel
AB-1015 0 Solar Panel
Fan Unit Base&Solar Panel Type:
Support: Wood Deck
(Design of support system is outside the scope of this evaluation)
Description:
• 15/32"or greater Plywood,or
• Wood plank deck(based on minimum density/specific gravity of 0.42)
Roof Slope: Slope shall be in compliance with FBC, Chapter 15 based on the type of roof covering.
Performance: Allowable Wind Resistance:
* Positive Design Pressure: +115 PSF
* Negative Design Pressure: -115 PSF
*Allowable design pressures for allowable stress design(ASD).
FL#: FL 13339.2 R6
`E3UCK EngineerinQ Date: 1/1/Z8
Report No.: 18- 01-SPAF-RemLP-S4W-ER
Page 3 of 8
SPIPCtc31hy Strtx_hurcal EnginPPrinq CBUCK,Inc.Certificate of Authorization#8064
Performance Standards: The following test protocol was performed to demonstrate compliance with the
intent of the code as this product does not specifically addressed the performance
standard in the code.
• ASTM E330-02--Standard Test Method forStructural Performance of Exterior
Windows, Curtain Walls, and Doors and by Uniform Static Air Pressure Difference
Code Compliance: The product described herein has demonstrated compliance with the Florida
Building Code 6th Edition (2017),Section 1708.2.
Evaluation Report Scope: This product evaluation demonstrates compliance of this product with the structural
wind load requirements of the Florida Building Code, as related to Florida Product
Approval Rule 61G20-3.001.
Limits of Use: • The Solar Attic Fan including solar panel and electrical wiring shall be installed in
compliance with Attic Breeze's installation instructions and in accordance with
applicable Building Codes
• Scope of"Limitations and Conditions of Use"for this evaluation:
This evaluation report for "Optional Statewide Approval" contains technical
documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61C20-3.004, the Florida Building Commission is
the authority to approve products under"Optional Statewide Approval".
• Option for application outside"Limitations and Conditions of Use"
Rule 61G20-3.005(l)(e) allows engineering analysis for "project specific
approval by the local authorities having jurisdiction in accordance with the
alternate methods and materials authorized in the Code". Any modification of
the product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the responsibility
of others.
• Refer to applicable building code section for ventilation requirements.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade&Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof vent products in accordance
with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a
quality assurance program audited by an approved quality assurance entity through
Keystone Certification,Inc.(FBC Organization#:QUA 1824)
FL#: FL 13339.2 R6
Date: 1/4/18
CBUCK Engineerinq Page Report
No.:
4 18-101-
g SPAF-RemLP-S4W-ER
SpeCialhy Structural Engineering CBUCK,Inc.Certificate of Authorization#8064
Component(s) Fan Unit
Material Standards: _ Nominal Dimension's
Fan House Base: 28" x 28"
Fan House Shroud/Dome: 21-1/2" x 21-1/2"
Overall Height: 10-3/4"
- Fan House Base&Shroud/Dome Material:
Material: Steel
Thickness: 22 ga.
Yield Strength: 33 ksi Minimum
Corrosion Resistance: Galvalume or Zincalume per ASTM A792 AZ 50
or in compliance with the FBC,Section 1507.4.3.
Solar Panel 20 Watts 30 Watts 40 Watts
Nominal Length: 19-1/4" 19-1/4" 26"
Nominal Width: 16-1/4" 16-1/4" 16-1/4"
Nominal Height: 1" 1" 1"
Frame Material: Aluminum
Frame Alloy 5052-H32
Low Profile Mounting Bracket(Four per Panel)
Material: Aluminum
Alloy: 5052-H32
Thickness: 0.125 in
Fastener(A) (Fan House Base to Roof Deck & Mounting Bracket to Roof Deck)
Type: Pancake Head Wood Screw
Size: #10 x 1 in. Minimum
Standard: Per ANSI/ASME B18.6.1
Corrosion Resistance: Per FBC Section 1506.6
Fastener(B) (Panel to Bracket)
Type: Hex-Head Machine Bolts and Nuts
Size 1/4 in.—20 x 3/4 in. Minimum
Washer: 1/4 in. Flat Washer&Lock Washer
Material: 18-8 Stainless Steel
Installation: Installation Method:
(Refer to Pages 6 through 8 of.this evaluation report.)
"The Solar Attic Fans" shall be installed in compliance with the installation method
listed in this report. The installation method described herein is in accordance with
the scope of this evaluation report. Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
FL M FL 13339.2 R6
rQ Date: 1/4/18
CBUCK Engineering Page rt No.:
5 18-10
81-5PAF-RemLP-S4W-ER
Spec-lcafi%j Structural Englneerinq CBUCK,Inc.Certificate of Authorization#8064
Evaluated Referenced Data: 1. ASTM E330-02 - Uniform Static Air Pressure Difference Test
By Certified Testing Laboratories, Inc.(FBC Organization ID#TST 1577)
Project M CTLA 2002W, Dated: 11/20/09
2. Quality Assurance
By Keystone Certification, Inc. (FBC Organization ID#QUA 1824)
Attic Breeze, LLC. Licensee#740
3. Certification of Independence
By James L. Buckner,P.E. @ CBUCK Engineering
(FBC Organization#AN 1916)
4. Engineering Analysis
By CBUCK Engineering
Report#C09-194, Dated:12/1/09
Report#C16-164,Dated: 10/20/16
FL#: FL 13339.2 R6
Date: 1/4/18
CE3UCKEngineering Page No• 1 - g SPAF-RemLP-S4W-ER
Speclalty structural Engineerinq CBUCK,inc.Certificate of Authorization#8064
Installation Method
Attic Breeze, LLC.
Solar Attic Fan Attachment Assembly
NIT
Fan House Shroud
4 /4"
10S3J4"
-Fan House Base
41/4"
20" Dander
Fastener(A) RW4c d Deck Plyuwod Deck
#10x 1 Nrcal a Head Typical Opening 15/32'MrL
Abod Saew
Assembly Front Section View
2-1/4"
Fan House Stroud
4-
-Fan House Base
4-'
20" Diarneter
Fastener(A) Plywood Deck Plywood Deck
#10 x 1" 9=ke-Head Typical Opening 1932"Mn.
Wad Sa'ew
Assembly Side Section View
FL#: FL 13339.2 R6
Date: 1/4/18
CBUCK r=f1Q1nPSr1nQ Report No.: 1- g-SPAF-RemLP-S4W-ER
Spe ctaN Struc-turcal Engincaerinq CBUCK,Inc.Certificate of Authorization#8064
Installation Method
Attic Breeze, I.I.C.
Solar Attic Fan Attachment Assembly
rjqg
r
. Da*
15132'Mn.
Assembly Top Plan View
FL#: FL 13339.2 R6
Date: 1/4/18
CSUCK Engineering Report No.: 188of 081-SPAF-RemLP-S4W-ER
rsp
ecialty Structural Engineering CBUCK,inc.Certificate of Authorization#8064
Installation Method
Attic Breeze, LLCI
Remote Mounted Solar Panel Attached Assembly
Table A
Wdth Solar Flanel
Model No. ; No.of Panels per Fan Unit
TjTical Low Profile AB-201D 1 S o-1-a-r Panel
Mamdng Bracket -
o AB-202D 1 Solar Panel
A13-2516 1 Solar Panel
AB-252D 1 Solar Panel
1-71 AB 401 2 Solar Panels
I AB-402 2 Solar Panels
Length 15' i AB-2022D 1 Solar Panel
AB-3022D 1 Solar Panel
AB-4022D 1 Solar Panel
AB-1015 0 Solar Panel
Table B
Solar Panel
F
Nominal Dimensions
j Type: 20 Watts 1 30 Watts 40 Watts
Solar Panel Assembly Length: 19-1/4" - 19-1/4" 25'
Plan View Width: 16-1/4" 16-1/4" 16-1/4"
Height.
Solar Panel
Solar Par�
r-astener(B)
114'-20 Hex Nut Low Profile Mounting Bracket
1/4'LockVlxher
1!4"Fiat V1a.shei°
1/4"Flat V4xsher Fastener(A)
1W-20 x314 #10 x 1"Pancake Head
Flex-Head VVmd Screw
Machine Bolt i4 Plywood Deck
15r32'Mn.
Solar Panel Assembly
Section View&Attachment Detail