Loading...
HomeMy WebLinkAboutAPPROVED Attic Fan Professional Regulation . BM Home I Login I User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff Boo Site Map E Links Search,i• ba OUSER.'Pubhe Product Approval User Product Aparoval Menu>Product or Application Search>Application List>Application petal] ® FL# FL13339-R6 Application Type Revision Code Version 2017 Application Status Approved Comments Archived [] Product Manufacturer Attic Breeze Address/Phone/Email 1370 FM 116 Gatesville,TX 76528 (254)865-9999 travis.hipp@atticbreeze.net Authorized Signature James Buckner jimmy@cbuckinc.net Technical Representative Travis Hipp Address/Phone/Email 1370 FM 116 Gatesville,TX 76528 (877)288-4234 travis.hipp@atticbreeze.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer C1 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed James L.Buckner,P.E.@ CBUCK Engineering the Evaluation Report Florida License PE-31242 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 12/01/2029 Validated By Michael John Werner,P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL13339 R6 COI COI CertOf Indeo James BUCkner.P.E.sc.PDF Referenced Standard and Year(of Standard) Equivalence of Product Standards Certified By Sections from the Code 1708.2 Product Approval Method Method 2 Option B Date Submitted 01/05/2018 Date Validated 01/05/2018 Date Pending FBC Approval O1/10/2018 Date Approved 04/10/2018 Summary of Products FL# Model,Number or Name Description 13339.1 OS_Solar Attic Fan Models AB-201A,AB-202A,AB-251A,AB-252A,AB-2022A, AB-3022A&AB-4022A.Self-flashing,solar powered fan units,with solar panel directly attached to fan unit shroud/dome Limits of Use Installation Instructions Approved for use in HVHZ:No FL13339 R6 II 1-7 Attic Breeze-SPAF Panel Direct to Flush Approved for use outside HVHZ:Yes Mount Unit EvalReportt.pdf Impact Resistant:No Verified By:James L. Buckner, P.E. @ CBUCK,Inc.P.E. Design Pressure:+115/-115 #31242 other: Refer to evaluation report for limitations and Created by Independent Third Party:Yes conditions of use. Refer to manufacturer's installation Evaluation Reports instructions as a supplemental guide. FL13339 R6 AE 1-7 Attic Breeze-SPAF Panel Direct to Flush Mount Unit EvalReoort.pdf Created by Independent Third Party:Yes 13339.2 02_Solar Attic Fan Models AB-201D,AB-202D,AB-251D,AB-252D,AB-401,AB- 402,AB-2022D,AB-3022D&AB-4022D.Self-flashing,solar powered fan units,with solar panel(s)remotely attached from fan unit,using low profile mounting brackets Limits of Use Installation Instructions Approved for use in HVHZ:No FL13339 R6 II 2 7 Attic Breeze-SPAF Panel Remote to Low Approved for use outside HVHZ:Yes Profile EvalReoort.oddf Impact Resistant.No Verified By: James L. Buckner,P.E. @ CBUCK,Inc.P.E. Design Pressure:+115/-115 #31242 Other:Refer to evaluation report for limitations and Created by Independent Third Party:Yes conditions of use.Refer to manufacturer's Installation Evaluation Reports Instructions as a supplemental guide. FL13339 R6 AE 2-7 Attic Breeze-SPAF Panel Remote to Low Profile EvalReport.odf Created by Independent Third Party;Yes 13339.3 03_Solar Attic Fan Models AB-201D,AB-202D,AB-251D,AB-252D,AB-401,AB- 402,AB-2022D,AB-3022D&AB-4022D. Self-flashing,solar powered fan units,with solar panel(s)remotely attached from fan unit,using universal mounting bracket Limits of Use Installation Instructions Approved for use in HVHZ:No Fi 13339 R6 II 3 7 Attic Breeze-SPAF Panel Remote Approved for use outside HVHZ:Yes Inclined EvalReport.odf Impact Resistant:No Verified By: James L.Buckner,P.E. @ CBUCK,Inc.P.E. Design Pressure: +115/-115 #31242 Other:Refer to evaluation report for limitations and Created by Independent Third Party:Yes conditions of use.Refer to manufacturer's installation Evaluation Reports instructions as a supplemental guide. FL13339 R6 AE 3-7 Attic Breeze-SPAF Panel Remote Inclined EvalReoort.odf Created by Independent Third Party:Yes 13339.4 04_Solar Attic Fan Models AB-601,AB-602&AB-6022D.Self-flashing,solar powered fan units,with solar panel remotely attached from fan unit,using low profile mounting brackets Limits of Use Installation Instructions Approved for use in HVHZ:No FL13339 R6 II 4-7 Attic Breeze-SPAF Panel Remote to Low Approved for use outside HVHZ:Yes Profile EvalReoort.pdf Impact Resistant:No Verified By:James L. Buckner,P.E. @ CBUCK,Inc.P.E. Design Pressure:+115/-115 #31242 Other:Refer to evaluation report for limitations and Created by Independent Third Party:Yes conditions of use.Refer to manufacturer's installation. Evaluation Reports instructions as a supplemental guide. FL13339 3339 R6 AE 4-7 Attic Breeze-SPAF Panel Remote to Low Profile EvalReoort.odf Created by Independent Third Party:Yes 13339.5 05_Solar Attic Fan Models AB-601,AB-602&AB-6022D.Self-flashing,solar powered fan units,with solar panel remotely attached from fan unit,using universal mounting brackets Limits of Use Installation Instructions Approved for use in HVHZ:No FL13339 R6 II 5-7 Attic Breeze-SPAF Panel Remote Approved for use outside HVHZ:Yes Inclined EyaIReDort.Ddf Impact Resistant:No Verified By:James L. Buckner,P.E. @ CBUCK,Inc..P.E. Design Pressure:+115/-115 #31242 Other:Refer to evaluation report for limitations and Created by Independent Third Party:Yes conditions of use.Refer to manufacturer's installation Evaluation Reports instructions as a supplemental guide. FL13339 R6 AE 5-7 Attic Breeze-SPAF Panel Remote Inclined EvalReoort.odf Created by Independent Third Party; Yes 13339.6 06_Cardinal Ventilation Models CV-2000&CV-3000.Self-flashing,circular shaped solar powered fan units,with solar panel directly attached to fan unit hood/dome Limits of Use Installation Instructions Approved for use in HVHZ:No FL13339 R6 iI 6-7 AS-Cardinal SPAF Panel Direct to Flush Approved for use outside HVHZ:Yes Mount Unit EvalReoort.Ddf Impact Resistant:No Verified By:James L. Buckner,P.E.@ CBUCK,Inc.P.E. Design Pressure:+115/-115 #31242 Other:Refer to evaluation report for limitations and Created by Independent Third Party:Yes conditions of use.Refer to manufacturer's installation Evaluation Reports instructions as a supplemental guide. FL113339 R6 AE 6-7 AB-Cardinal SPAF Panel Direct to Flush Mount Unit EvalReport.odf Created by Independent Third Party:Yes 13339.7 Curb Mount Series Curb Profile vent fan base for attachment to roof curbs Limits of Use Installation Instructions Approved for use in HVHZ:No FI 13339 R6 II 7-7 Curb-SPA-CM-ER W 10 odf Approved for use outside HVHZ:Yes Verified By:James L Buckner,P.E.@CBUCK,Inc P.E.# Impact Resistant:No 31242 Design Pressure:+115/-115 Created by Independent Third Party:Yes Other:Refer to evaluation report for limitations and Evaluation Reports conditions of use. FI t3339 R6 AE 7-7 Curb-SPA-CM-ER W 10 odf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stane Roatl Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.;please click here. Product Approval Accepts: Credit Card Safe CBUCK Engineerinq Specica tLj Structural Eriglr�erinq CBUCK,Inc.Certificate of Authorization#8064 Evaluation Report "Solar Attic Fans" Self-Flashing Series with Low Profile Remote Mounted Solar Panel 20 Watts;30 WaM & 40 Watts Solar Panels Manufacturer Attic Breeze, LLC. 1370 F M 116 Gatesville, Texas 76528 (877)288-4234 for Florida Product Approval # FL 13339.2 R6 Florida Building Code 6th Edition (2017) Per Rule 61G20-3 Method: 2- B Category: Roofing Sub - Category: Roofing Accessories that are an Integral Part of the Roofing System Product Names: Solar Attic Fans Product Description: Self-Flashing Series with Low Profile Remote Mounted Solar Panel Facsimile of digital copy signed by James L.Buckner,P.E. Prepared by: Electronically signed and sealed documents sh James L. Buckner, P.E.,SECB comply with the provisions of FAC Rule 61G15-: Florida Professional Engineer#31242 Florida Evaluation ANE ID: 1916 �� ��cenlsF'•-cc,P Report No. 18-101-SPAF-RemLP-S4W-ER =*' No31242 " Date: 1/4/18 --o Luz Contents: =�i(�'. STATE OF Evaluation Report Pages 1—8 Fs'' •F�oR... /O N A\�\\\\ CBUCK,Inc. - Palm Beach County,Florida 2018.01.0415.00:37-05'00' Phone:(561)491-9927•Email:cbuck@cbuckinc.net•Website:www.cbuckinc.net FL#: FL 13339.2 R6. //''''''�� Date: 1/4/18 (. BUCK Engineerinq Report No.: 2 of 081-SPAF-RemLP-S4W-ER SpectaH-L j Structural Engtneertnq CBUCK,Inc.Certificate of Authorization#8064 Manufacturer: Attic Breeze,LLC. Product Name: Solar Attic Fans Product Category: Roofing Product Sub-Category Roofing Accessories that are an Integral part of the Roofing System Compliance Method: State Product Approval Rule 61G20-3.005 (2)(b) Product Description: The Solar Attic Fan is a roof mounted system powered by one or two solar panels. The unit consists of a 14 inch diameter fan,enclosed in a-self-flashing fan house base vent, with corrosion resistant zincalume alloy steel housing, including a thermal switch, and a rodent guard.solar panel is remotely attached from the fan house unit shroud/dome. Product Assembly as Self-flashing solar attic fan with low profile remote mounted solar panel Evaluated: - Fan house base unit component mechanically attached to deck Solar panel remotely attached to four (4) low profile mounting brackets with machine bolts - Low profile mounting brackets attached to roof deck with screws Model Numbers: No./Designation No.of Solar Panel AB-201D 1 Solar Panel AB-202D 1 Solar Panel AB-251D 1 Solar Panel AB-252D 1 Solar Panel AB-401 2 Solar Panels AB-402 2 Solar Panels AB-2022D 1 Solar Panel �t AB_ 3022D , 1 Solar Panel AB-4022D 1 Solar Panel AB-1015 0 Solar Panel Fan Unit Base&Solar Panel Type: Support: Wood Deck (Design of support system is outside the scope of this evaluation) Description: • 15/32"or greater Plywood,or • Wood plank deck(based on minimum density/specific gravity of 0.42) Roof Slope: Slope shall be in compliance with FBC, Chapter 15 based on the type of roof covering. Performance: Allowable Wind Resistance: * Positive Design Pressure: +115 PSF * Negative Design Pressure: -115 PSF *Allowable design pressures for allowable stress design(ASD). FL#: FL 13339.2 R6 `E3UCK EngineerinQ Date: 1/1/Z8 Report No.: 18- 01-SPAF-RemLP-S4W-ER Page 3 of 8 SPIPCtc31hy Strtx_hurcal EnginPPrinq CBUCK,Inc.Certificate of Authorization#8064 Performance Standards: The following test protocol was performed to demonstrate compliance with the intent of the code as this product does not specifically addressed the performance standard in the code. • ASTM E330-02--Standard Test Method forStructural Performance of Exterior Windows, Curtain Walls, and Doors and by Uniform Static Air Pressure Difference Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 6th Edition (2017),Section 1708.2. Evaluation Report Scope: This product evaluation demonstrates compliance of this product with the structural wind load requirements of the Florida Building Code, as related to Florida Product Approval Rule 61G20-3.001. Limits of Use: • The Solar Attic Fan including solar panel and electrical wiring shall be installed in compliance with Attic Breeze's installation instructions and in accordance with applicable Building Codes • Scope of"Limitations and Conditions of Use"for this evaluation: This evaluation report for "Optional Statewide Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61C20-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval". • Option for application outside"Limitations and Conditions of Use" Rule 61G20-3.005(l)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Refer to applicable building code section for ventilation requirements. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade&Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof vent products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certification,Inc.(FBC Organization#:QUA 1824) FL#: FL 13339.2 R6 Date: 1/4/18 CBUCK Engineerinq Page Report No.: 4 18-101- g SPAF-RemLP-S4W-ER SpeCialhy Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Component(s) Fan Unit Material Standards: _ Nominal Dimension's Fan House Base: 28" x 28" Fan House Shroud/Dome: 21-1/2" x 21-1/2" Overall Height: 10-3/4" - Fan House Base&Shroud/Dome Material: Material: Steel Thickness: 22 ga. Yield Strength: 33 ksi Minimum Corrosion Resistance: Galvalume or Zincalume per ASTM A792 AZ 50 or in compliance with the FBC,Section 1507.4.3. Solar Panel 20 Watts 30 Watts 40 Watts Nominal Length: 19-1/4" 19-1/4" 26" Nominal Width: 16-1/4" 16-1/4" 16-1/4" Nominal Height: 1" 1" 1" Frame Material: Aluminum Frame Alloy 5052-H32 Low Profile Mounting Bracket(Four per Panel) Material: Aluminum Alloy: 5052-H32 Thickness: 0.125 in Fastener(A) (Fan House Base to Roof Deck & Mounting Bracket to Roof Deck) Type: Pancake Head Wood Screw Size: #10 x 1 in. Minimum Standard: Per ANSI/ASME B18.6.1 Corrosion Resistance: Per FBC Section 1506.6 Fastener(B) (Panel to Bracket) Type: Hex-Head Machine Bolts and Nuts Size 1/4 in.—20 x 3/4 in. Minimum Washer: 1/4 in. Flat Washer&Lock Washer Material: 18-8 Stainless Steel Installation: Installation Method: (Refer to Pages 6 through 8 of.this evaluation report.) "The Solar Attic Fans" shall be installed in compliance with the installation method listed in this report. The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. FL M FL 13339.2 R6 rQ Date: 1/4/18 CBUCK Engineering Page rt No.: 5 18-10 81-5PAF-RemLP-S4W-ER Spec-lcafi%j Structural Englneerinq CBUCK,Inc.Certificate of Authorization#8064 Evaluated Referenced Data: 1. ASTM E330-02 - Uniform Static Air Pressure Difference Test By Certified Testing Laboratories, Inc.(FBC Organization ID#TST 1577) Project M CTLA 2002W, Dated: 11/20/09 2. Quality Assurance By Keystone Certification, Inc. (FBC Organization ID#QUA 1824) Attic Breeze, LLC. Licensee#740 3. Certification of Independence By James L. Buckner,P.E. @ CBUCK Engineering (FBC Organization#AN 1916) 4. Engineering Analysis By CBUCK Engineering Report#C09-194, Dated:12/1/09 Report#C16-164,Dated: 10/20/16 FL#: FL 13339.2 R6 Date: 1/4/18 CE3UCKEngineering Page No• 1 - g SPAF-RemLP-S4W-ER Speclalty structural Engineerinq CBUCK,inc.Certificate of Authorization#8064 Installation Method Attic Breeze, LLC. Solar Attic Fan Attachment Assembly NIT Fan House Shroud 4 /4" 10S3J4" -Fan House Base 41/4" 20" Dander Fastener(A) RW4c d Deck Plyuwod Deck #10x 1 Nrcal a Head Typical Opening 15/32'MrL Abod Saew Assembly Front Section View 2-1/4" Fan House Stroud 4- -Fan House Base 4-' 20" Diarneter Fastener(A) Plywood Deck Plywood Deck #10 x 1" 9=ke-Head Typical Opening 1932"Mn. Wad Sa'ew Assembly Side Section View FL#: FL 13339.2 R6 Date: 1/4/18 CBUCK r=f1Q1nPSr1nQ Report No.: 1- g-SPAF-RemLP-S4W-ER Spe ctaN Struc-turcal Engincaerinq CBUCK,Inc.Certificate of Authorization#8064 Installation Method Attic Breeze, I.I.C. Solar Attic Fan Attachment Assembly rjqg r . Da* 15132'Mn. Assembly Top Plan View FL#: FL 13339.2 R6 Date: 1/4/18 CSUCK Engineering Report No.: 188of 081-SPAF-RemLP-S4W-ER rsp ecialty Structural Engineering CBUCK,inc.Certificate of Authorization#8064 Installation Method Attic Breeze, LLCI Remote Mounted Solar Panel Attached Assembly Table A Wdth Solar Flanel Model No. ; No.of Panels per Fan Unit TjTical Low Profile AB-201D 1 S o-1-a-r Panel Mamdng Bracket - o AB-202D 1 Solar Panel A13-2516 1 Solar Panel AB-252D 1 Solar Panel 1-71 AB 401 2 Solar Panels I AB-402 2 Solar Panels Length 15' i AB-2022D 1 Solar Panel AB-3022D 1 Solar Panel AB-4022D 1 Solar Panel AB-1015 0 Solar Panel Table B Solar Panel F Nominal Dimensions j Type: 20 Watts 1 30 Watts 40 Watts Solar Panel Assembly Length: 19-1/4" - 19-1/4" 25' Plan View Width: 16-1/4" 16-1/4" 16-1/4" Height. Solar Panel Solar Par� r-astener(B) 114'-20 Hex Nut Low Profile Mounting Bracket 1/4'LockVlxher 1!4"Fiat V1a.shei° 1/4"Flat V4xsher Fastener(A) 1W-20 x314 #10 x 1"Pancake Head Flex-Head VVmd Screw Machine Bolt i4 Plywood Deck 15r32'Mn. Solar Panel Assembly Section View&Attachment Detail