HomeMy WebLinkAboutAPPROVED Roof Metal Business & Professional Regulation'
eQS Heme ; Log In I Ustr Reg
lstratien HntTepirs I Submit Surcharge Stets&Facts I Publications j Cantaa Us Ecis Slte Map € Lnls Search i
lorida
Product Approval
USER:Public User
Product Aaaroval Menu>Pmduer cr-Aoolkatlon Search>Awllcatian tier>Applicatien oxtail
FL# FL17022-R7
Appiication Type Revision
Code Version 20i7
Application Status Approved
Comments 08/18/2017v.date reapply 08/21/17
Archived Ll
Product Manufacturer Extreme Metal Fabricators,LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
fivalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidetion@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
richard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
17 Evaluation Report-Hardcapy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2024 -.
Validated By Zachary R.Priest,P.E.
Q Validation Checklist-Hardcopy Received
Certificate of Independence FL17022 R7 COI FL 17022 i S V CRIMP car p_df
Referenced Standard and Year(of Standard) 5andard Yvan
TAS 125 2003
UL 1897 ,•• 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Z�)
Product Approval Method Method i Option D
Date Submitted 08/18/2017
Date Validated 08/25/2027
Date Pending FBC Approval 08/28/2017
Date Approved 1 0/1 012 0 17
Summary of Products
FL# Model,Number or Name Description
17022.1 1-"5V Crimp"(116) 26 Gauge steel,3/8"rib height,24"wide lapped roof panel
mechanically attached to 15/32"plywood or Wood Deck with
fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022 1 5 V CRIMP ssr odP
Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions.Install the. FL17022 R7 AE FL 17022.1 5 V CRIMP sr odf
assembly in compliance with the installation method listed in Created by Independent Third Party;Yes
this report and applicable code sections of FBC.Refer to
manufacturer's installation instructions.
17022.2 2-"5V Crimp"(R6) 0.032"Aluminum,3/8"Rib height,21'wide lapped roof
panel,mechanically attached to 15/32"plywood or Wood
Deck with exposed fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ:No FIL n R7 II FL 17022.2 5 V CRIMP 0 0 2 ALUM ssr.pdf
Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure.+N/A/-Table A Evaluation Reports
Other;Refer to evaluation report for conditionsanstall the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr pdf
assembly in compliance with the Installation method listed In Created by Independent Third Party:Yes
this report and applicable code sections of FBC.Refer to
manufacturer's Installation Instructions.
17022.3 3-"1.5"Mechanical Seam"(115) 1.5"rib height,16"wide,24 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with clips and fasteners.
Limits of Use Installation Instructio
Approved for use In HVHZ:No FL17022 R7 II FL 170ns 1 MFCHANICAL
Approved for use outside HVHZ:Yes seam 24cia ssr.odf
Impact Res➢scant:No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly in compliance with the FL17022 R7 AE FL 17022 3 1.5 MECHANICAL
installation method listed in this report and applicable code seam 24aa ssr.odf
sections of FBC.Refer to manufacturer's Installation Created by Independent Third Party:Yes
Instructions.
17022.4 4-"1.5"Mechanical Seam"(R5) 1.5"rib height,15"wide,0.032"aluminum,standing seam
roof panel mechanically attached to 15/32"plywood or Wood
Deck with clips and fasteners.
Limits of Use Installation Instructions
Approved for use In HVHZ:No F-L17022 R7 IT FL 17022A MF_C_HANC_iAL_REAM
Approved for use outside HVHZ:Yes ALUMINUM ssr.odf
Impact Resistant:No Verified By:Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other.Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly in compliance with the FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
installation method listed in this report and applicable code ALUMINUM ssr.odf
sections of FBC.Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
1702Z5 5-"1 in.Nail Strip"(115) 1"rib height,16"wide,26 gauge steel,standing seam roof
panel mechanically attached to 15132"plywood or wood deck
with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 TI FL 17022.5 1,0 NAILSrRIP ssr.odf
Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Parry:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions and FL17022 R7 AE FL17022.5 1,0 NAILSrRIP ssr.adf
limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes
Installation method listed In this report and applicable code
sections of FBC.Refer to manufacturer's Installation
instructions.
17022.6 6-"1 in.Nall Strip"(115) 1"rib height,16"wide,0.032'aluminum,standing seam roof
pane(mechanically attached to attached to 13/32"plywood or
Wood Deck with fasteners,
Umits of Use Installation Instructions
Approved for use In HVHZ:No FL17022_R7 II FL 17022.6 1.0 NAIL STRIP 0.032
Approved for use outside HVHZ:Yes ALUM ssr.pdF
Impact Resistant:No Verified By:Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other.Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly in compliance with the FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
Installation method listed in this report and applicable code ALUM ssr.odf
sections of FBC,Refer to manufacturer's Installation Created by Independent Third Party:Yes
Instructions.
17022.7 7-"1.5 in.Nail Strip"(115) 1.5"rib height,19"wide,26 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 11 FL 17022,7 1.5 Nall Strip 26GA ssr odf
Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022 7 1.5 Nail Strip 26GA ssr odf
limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes
installation method listed in this report and applicable code
sections of FBC.Refer to manufacturer's Installation
Instructions.
17022.8 8-"EMAX Rib"(115) 29 gauge steel,lapped roof panel mechanically attached to
15/32"plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use In HVHZ:No EL17022 R7 II FL 177022.8 EMAX Rib_ssr odf
Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 177022.8 EMAX Rib ssr,odf
limitations of use.Install the assembly In compliance with the Created by Independent Third Party:Yes
Installation method listed in this report and applicable code
sections of FBC.Refer to manufacturers installation
instructions.
17022.9 9-"PBR MAX"(RS) 26 gauge steel,lapped roof panel mechanically attached to
15132"plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL17022 R7 II FL 17022.9 PBR RIB ssr.Ddf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022 9 PBR RIB ssr odf
limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes
installation method listed In this report and applicable code
sections of FBC.Refer to manufacturer's installation
instructions.
Contact Us..-2rn1 Blair stone Road.Ta0a11assee FL 32399 Phone-85a-487-1824• '
The State of Florida is an AA/EEO employer.Copyright 2007-2013 state cf Florida.::Pdvaev statement::Actessibnity statement::Retind Statement
Under Florida law,email addresses ate public records.Ifyou do not want your a•mall address released In response to a public-mcords request,do not send electronic -
mail to this entity.Instead,contact.the ofBcc by phone or by traditional mall.If you have any questions,please contact 850.487.1395,*pursuant to Section 455.275(1),
Flodda statutes,effecth,e octaber 1,2012,licensees licensed under Chapter 455,F.S.must provide the Dapartmwt with an emall address If they have one.The emails
provided may be used for official communication with the licensee.However small addresses are publlc record.If ycu do net wish to supply a personal address,please
provide the Department with an emall address which can be made available to the public.To determine If you area licensee under Chapter 455,F.S.,please dicks)—.
Product Approval Accepts:
®®®ER®
Credit Card
Safe
t
:'ProdLfct Report
2160 SW Poma Dria►e
Palm,City,FL 34990
7n)sn-8034
Product •
Compliant with Florida Building Code 2017(6th ed.)
Compliant with Florida Product Approval Rule#61620-3
` Compliant: Keystone Certifications
Product:5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2
Yield strength:50 ksi min.;Attached to min.15/32"plywood or Wood
{ Deck w/min.OA2 specific gravity with screws. 24rr Coverage
Rib Height 318"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1(Method 1 Attachment):#9 x 11/2"Hex-Washer Head wood screw*to penetrate
3/16" min.thru deck or S/8"embedment into wood plank.(*or sufficient length to meet
requirements)
Fastener 2(Method 2,3,&4 Attachment):#10 x 1-1/2"Hex-Washer Head wood screw*to .
penetrate 3/16"min.thru deck or 5/811 embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec.Chart 1S07.1.1
Slope:Shall be in compliance with FBC Sec.1507.
See Fastener attachment specifications above
install Details: Table A -Allowable Loads METHOD 1 . METHOD,2. METHOD 3 METHOD 4
DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF 2-28 PSF
ROW SPACING 16r O.C. 16"o.c. 8"O.C. 6"O.C.
FASTENER SPACING(Awns Panel width) 12"o.c. 12"o.c. 12"o.c. 12"O.C.
FASTENER SIZE ##9 1 #10 #10 1 #10
Reference Data: ARCHITECTURAL TESTING,INC.TST Of 1527
UL 580-06&1897-041 Test Report =893A1-450-18 05/02/14
Test Report F3366 OI-450-18 12/18115
TAS 125-03 Test Report . D05893.02-450-18 07/22/14
*EQMVALEWY--UL 1897-04 is egniva/entiw•teststandard UL i897--•Z *Design pressure margin ofsafewz.,l
t Itll!
Locke Bowden,P.E.does not have,not will acquire a financial intgC"eF£ 4�mfacturing or distributing products
under this evaluation. �' •;
Locke Bowden,P.E.is not owned,operated,or controlled by a&cotnparft3mit413fittturer,or distributing products under this
report, ,.,.visfr4i'
a a
i'
��.,�rONAL.�•,s
i
FL17022.1 5V Crimp(26GA Steel),24"Wide Roof Panel -Details
L€rrlitatfons:
1.Underlayment to be compliance with current Florida Building Code(FBC)2017 6",ed.
2.Minimum slope to be compliant with Florida Building Code 2017 6th ed.,and per with Manufacturer's installation reference.
3.Products are compliant for State of Florida product approval per Rule 61G20-3.Compliance Method:1-D
4.Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5.Fire classification is not part of this acceptance.Shear diaphragm values are outside this report.
6.Support framing in compliance w/FBC 2017 6th ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7.This report does not imply warranty,Installation,recommended product use outside of this report.
Fastenem
#9x1-U2"Mh or
#10 x 1 IMI Min.perrWe"A"far Row 5-v c mP Roof Panei
r SPaa1nB 9deslgnPressrnes
lie xwasherHeadlNoal Screws
fit
Deck
IEWorgreaterPlM ,or
.Nbod plank
� 1
Pagel Profile
Nominal 12" Nominal I Z'
O.C. P.C.
Fasten
x 1-1121-M€n. or#10 x 1-1/2"Min.per
abie"A" Hex Washer Head Screw
Spaced 12"O.G.across the Panel Wdth
Panel Referto Table"A'for Spacing Along Panel
Overlap Length
Deck 15/32"or greater
Plywood,or
-Wood plank