Loading...
HomeMy WebLinkAboutAPPROVED Roof Metal Business & Professional Regulation' eQS Heme ; Log In I Ustr Reg lstratien HntTepirs I Submit Surcharge Stets&Facts I Publications j Cantaa Us Ecis Slte Map € Lnls Search i lorida Product Approval USER:Public User Product Aaaroval Menu>Pmduer cr-Aoolkatlon Search>Awllcatian tier>Applicatien oxtail FL# FL17022-R7 Appiication Type Revision Code Version 20i7 Application Status Approved Comments 08/18/2017v.date reapply 08/21/17 Archived Ll Product Manufacturer Extreme Metal Fabricators,LLC Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 fivalidation@yahoo.com Authorized Signature Richard McKuhen flvalidetion@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 17 Evaluation Report-Hardcapy Received Florida Engineer or Architect Name who developed LOCKE BOWDEN the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/22/2024 -. Validated By Zachary R.Priest,P.E. Q Validation Checklist-Hardcopy Received Certificate of Independence FL17022 R7 COI FL 17022 i S V CRIMP car p_df Referenced Standard and Year(of Standard) 5andard Yvan TAS 125 2003 UL 1897 ,•• 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Z�) Product Approval Method Method i Option D Date Submitted 08/18/2017 Date Validated 08/25/2027 Date Pending FBC Approval 08/28/2017 Date Approved 1 0/1 012 0 17 Summary of Products FL# Model,Number or Name Description 17022.1 1-"5V Crimp"(116) 26 Gauge steel,3/8"rib height,24"wide lapped roof panel mechanically attached to 15/32"plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022 1 5 V CRIMP ssr odP Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions.Install the. FL17022 R7 AE FL 17022.1 5 V CRIMP sr odf assembly in compliance with the installation method listed in Created by Independent Third Party;Yes this report and applicable code sections of FBC.Refer to manufacturer's installation instructions. 17022.2 2-"5V Crimp"(R6) 0.032"Aluminum,3/8"Rib height,21'wide lapped roof panel,mechanically attached to 15/32"plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ:No FIL n R7 II FL 17022.2 5 V CRIMP 0 0 2 ALUM ssr.pdf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure.+N/A/-Table A Evaluation Reports Other;Refer to evaluation report for conditionsanstall the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr pdf assembly in compliance with the Installation method listed In Created by Independent Third Party:Yes this report and applicable code sections of FBC.Refer to manufacturer's Installation Instructions. 17022.3 3-"1.5"Mechanical Seam"(115) 1.5"rib height,16"wide,24 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with clips and fasteners. Limits of Use Installation Instructio Approved for use In HVHZ:No FL17022 R7 II FL 170ns 1 MFCHANICAL Approved for use outside HVHZ:Yes seam 24cia ssr.odf Impact Res➢scant:No Verified By: Locke Bowden,P.E.49704 Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes Other:Refer to evaluation report for conditions and Evaluation Reports limitations of use.Install the assembly in compliance with the FL17022 R7 AE FL 17022 3 1.5 MECHANICAL installation method listed in this report and applicable code seam 24aa ssr.odf sections of FBC.Refer to manufacturer's Installation Created by Independent Third Party:Yes Instructions. 17022.4 4-"1.5"Mechanical Seam"(R5) 1.5"rib height,15"wide,0.032"aluminum,standing seam roof panel mechanically attached to 15/32"plywood or Wood Deck with clips and fasteners. Limits of Use Installation Instructions Approved for use In HVHZ:No F-L17022 R7 IT FL 17022A MF_C_HANC_iAL_REAM Approved for use outside HVHZ:Yes ALUMINUM ssr.odf Impact Resistant:No Verified By:Locke Bowden,P.E.49704 Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes Other.Refer to evaluation report for conditions and Evaluation Reports limitations of use.Install the assembly in compliance with the FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM installation method listed in this report and applicable code ALUMINUM ssr.odf sections of FBC.Refer to manufacturer's installation Created by Independent Third Party:Yes instructions. 1702Z5 5-"1 in.Nail Strip"(115) 1"rib height,16"wide,26 gauge steel,standing seam roof panel mechanically attached to 15132"plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 TI FL 17022.5 1,0 NAILSrRIP ssr.odf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Parry:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 R7 AE FL17022.5 1,0 NAILSrRIP ssr.adf limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes Installation method listed In this report and applicable code sections of FBC.Refer to manufacturer's Installation instructions. 17022.6 6-"1 in.Nall Strip"(115) 1"rib height,16"wide,0.032'aluminum,standing seam roof pane(mechanically attached to attached to 13/32"plywood or Wood Deck with fasteners, Umits of Use Installation Instructions Approved for use In HVHZ:No FL17022_R7 II FL 17022.6 1.0 NAIL STRIP 0.032 Approved for use outside HVHZ:Yes ALUM ssr.pdF Impact Resistant:No Verified By:Locke Bowden,P.E.49704 Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes Other.Refer to evaluation report for conditions and Evaluation Reports limitations of use.Install the assembly in compliance with the FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 Installation method listed in this report and applicable code ALUM ssr.odf sections of FBC,Refer to manufacturer's Installation Created by Independent Third Party:Yes Instructions. 17022.7 7-"1.5 in.Nail Strip"(115) 1.5"rib height,19"wide,26 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 11 FL 17022,7 1.5 Nall Strip 26GA ssr odf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022 7 1.5 Nail Strip 26GA ssr odf limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes installation method listed in this report and applicable code sections of FBC.Refer to manufacturer's Installation Instructions. 17022.8 8-"EMAX Rib"(115) 29 gauge steel,lapped roof panel mechanically attached to 15/32"plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use In HVHZ:No EL17022 R7 II FL 177022.8 EMAX Rib_ssr odf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 177022.8 EMAX Rib ssr,odf limitations of use.Install the assembly In compliance with the Created by Independent Third Party:Yes Installation method listed in this report and applicable code sections of FBC.Refer to manufacturers installation instructions. 17022.9 9-"PBR MAX"(RS) 26 gauge steel,lapped roof panel mechanically attached to 15132"plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use In HVHZ:No FL17022 R7 II FL 17022.9 PBR RIB ssr.Ddf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022 9 PBR RIB ssr odf limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes installation method listed In this report and applicable code sections of FBC.Refer to manufacturer's installation instructions. Contact Us..-2rn1 Blair stone Road.Ta0a11assee FL 32399 Phone-85a-487-1824• ' The State of Florida is an AA/EEO employer.Copyright 2007-2013 state cf Florida.::Pdvaev statement::Actessibnity statement::Retind Statement Under Florida law,email addresses ate public records.Ifyou do not want your a•mall address released In response to a public-mcords request,do not send electronic - mail to this entity.Instead,contact.the ofBcc by phone or by traditional mall.If you have any questions,please contact 850.487.1395,*pursuant to Section 455.275(1), Flodda statutes,effecth,e octaber 1,2012,licensees licensed under Chapter 455,F.S.must provide the Dapartmwt with an emall address If they have one.The emails provided may be used for official communication with the licensee.However small addresses are publlc record.If ycu do net wish to supply a personal address,please provide the Department with an emall address which can be made available to the public.To determine If you area licensee under Chapter 455,F.S.,please dicks)—. Product Approval Accepts: ®®®ER® Credit Card Safe t :'ProdLfct Report 2160 SW Poma Dria►e Palm,City,FL 34990 7n)sn-8034 Product • Compliant with Florida Building Code 2017(6th ed.) Compliant with Florida Product Approval Rule#61620-3 ` Compliant: Keystone Certifications Product:5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2 Yield strength:50 ksi min.;Attached to min.15/32"plywood or Wood { Deck w/min.OA2 specific gravity with screws. 24rr Coverage Rib Height 318" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment):#9 x 11/2"Hex-Washer Head wood screw*to penetrate 3/16" min.thru deck or S/8"embedment into wood plank.(*or sufficient length to meet requirements) Fastener 2(Method 2,3,&4 Attachment):#10 x 1-1/2"Hex-Washer Head wood screw*to . penetrate 3/16"min.thru deck or 5/811 embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec.Chart 1S07.1.1 Slope:Shall be in compliance with FBC Sec.1507. See Fastener attachment specifications above install Details: Table A -Allowable Loads METHOD 1 . METHOD,2. METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF 2-28 PSF ROW SPACING 16r O.C. 16"o.c. 8"O.C. 6"O.C. FASTENER SPACING(Awns Panel width) 12"o.c. 12"o.c. 12"o.c. 12"O.C. FASTENER SIZE ##9 1 #10 #10 1 #10 Reference Data: ARCHITECTURAL TESTING,INC.TST Of 1527 UL 580-06&1897-041 Test Report =893A1-450-18 05/02/14 Test Report F3366 OI-450-18 12/18115 TAS 125-03 Test Report . D05893.02-450-18 07/22/14 *EQMVALEWY--UL 1897-04 is egniva/entiw•teststandard UL i897--•Z *Design pressure margin ofsafewz.,l t Itll! Locke Bowden,P.E.does not have,not will acquire a financial intgC"eF£ 4�mfacturing or distributing products under this evaluation. �' •; Locke Bowden,P.E.is not owned,operated,or controlled by a&cotnparft3mit413fittturer,or distributing products under this report, ,.,.visfr4i' a a i' ��.,�rONAL.�•,s i FL17022.1 5V Crimp(26GA Steel),24"Wide Roof Panel -Details L€rrlitatfons: 1.Underlayment to be compliance with current Florida Building Code(FBC)2017 6",ed. 2.Minimum slope to be compliant with Florida Building Code 2017 6th ed.,and per with Manufacturer's installation reference. 3.Products are compliant for State of Florida product approval per Rule 61G20-3.Compliance Method:1-D 4.Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5.Fire classification is not part of this acceptance.Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 6th ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty,Installation,recommended product use outside of this report. Fastenem #9x1-U2"Mh or #10 x 1 IMI Min.perrWe"A"far Row 5-v c mP Roof Panei r SPaa1nB 9deslgnPressrnes lie xwasherHeadlNoal Screws fit Deck IEWorgreaterPlM ,or .Nbod plank � 1 Pagel Profile Nominal 12" Nominal I Z' O.C. P.C. Fasten x 1-1121-M€n. or#10 x 1-1/2"Min.per abie"A" Hex Washer Head Screw Spaced 12"O.G.across the Panel Wdth Panel Referto Table"A'for Spacing Along Panel Overlap Length Deck 15/32"or greater Plywood,or -Wood plank