Loading...
HomeMy WebLinkAboutPlan Review RecordFA ..........�.�.. -f 5 t_ ICC Copyright 20r09 International Code Council„ I'nc Reproduction by any means is prohibited ICC is „' 1 the trademark of International Code Council, Iri :, and is registered in the U.S,.,Patenit and Trademark Office. For additional forms, contact: • , r , INTERNATIONAL CODE COUNCIL, INC. PHONE 1-888-ICC-SAFE, WWW.ICCSAFE.ORG . ": Item,'' d CORRECTION LIST (cont'd.) Code No. DESCRIPTION Section -2- -CORRECTION LIST (cont'd.) Code No. DESCRIPTION Section '3- NOTES: N.R. —Not required N.A. — Not applicable ADMNSTRAMN. (Chapter 1) Complete construction documents Signed/sealed construction documents (107.1, 107.2) (107.1, State laws vary) BMDING PLANNNG (Chapters 3, 4, 5, 6) OCCUPANCY CLASSIFICATION (302 - 3'12, 508) ZSingle Occupancy (302.1) Incidental accessory occupancies Mixed Occupancy (508,1) (5082.5, Table 508.2.5) Accessory occupancies (508.2) GENERAL BUILDING LIMITATIONS (Chapters 5 & 6) Address identification (501.2) Apply Case 1 to determine the allowable height and area and permitted types of construction for a building containing a single occupancy or nonseparated mixed occupancies. Apply Case 2 to determine the allowable height and area and permitted types of construction for a building containing separated mixed occupancies. AREA MODIFICATIONS TO TABLE 503 Allowable tabular area, At (Table 503) 1 Area Increase Factor due to frontage, If (506.2) + Area Increase Factor due to automatic sprinklers, Is (506.3) + Conversion factor = Frontage (506.2) North East South West Total Frontage Width of open space (W) _ Area Increase Factor due to frontage, It= (506.2) Perimeter (P) ft. If = CP — 0.25] W CASE 1 — SINGLE OCCUPANCY OR NONSEPARATED MIXED OCCUPANCIES (508.3) Using Table 503, identify the allowable height and area of the single occupancy or the most restrictive of the nonseparated mixed occupancies. Construction types that provide an allowable tabular area equal to or greater than the adjusted building area and allowable heights (as modified by Section 504) equal to or greater than the actual building height are permitted. DETERMINE CONSTRUCTION TYPE CHECK ALLOWABLE AREA (506.4) Actual building area Allowable area per floor (Aa) Adjusted building area ft2 X = ft2 actual building area _ conversion factor conversion factor tabular area (Table 503) Actual building height feet stories Total floor area (all stories) ft2 Allowable building height Permitted types of construction Type of construction assumed for review (602.1) feet stories Allowable floor area (all stories) X = ft2 Allowable area per floor number of stories (AJ (maximum 3) Compliance verified -4- ' F CASE 2 —SEPARATED MIXED OCCUPANCIES (508.4) Using Table 503, identify the allowable height and area of each of the separated occupancies within the building. Construc- tion types that provide, for each story of the building, tabular areas (as modified by Section 506) which result in a surn of the ratios of 1.00 or less and allowable heights (as modified by Section 504) equal to or greater than the actual height of the occupancy are permitted. Actual Adjusted Actual Allowable . Story Group floor area floor area* height height ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft stories ft2 ff ft stories ft stories ft2 ft2 ft stories.. ft stories ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft -stories ft2 ft2 ft stories ft stories Adjusted floor area Area ratio (single floor)= + + + _ _<100 Allow. tab. area, A, (Table 503) *Adjusted floor area = actual floor area = conversion factor" CHECK ALLOWABLE AREA (506.5) Permitted types -of construction Three stories or less buildings Type of construction assumed for review (602..1) Four or more story buildings (Total area ratio < 3) Compliance verified MEZZANINES (505) Area limitation (505.2) Openness (505.4) Egress (505.3) Equipment platforms (505.5) UNLIMITED AREA BUILDINGS (507) Nonsprinklered, one story (507.2) Group H occupancies (507.8) Sprinklered, one story (507.3) Aircraft paint hangar (507.9) Two story (507.4) Group E buildings (507.10) Reduced open -space (507.5) Motion picture theaters (507.11) Group A-3 buildings (507.6, 507.7) Covered mall buildings/anchor stores . (507.12) SPECIAL PROVISIONS (509) Special condition applicable (509.1) Compliance verified SPECIAL DETAILED REQUIREMENTS EASED ON USE AND OCCUPANCY (Chapter 4) COVERED MALL AND OPEN MALL BUILDINGS (402) Smoke control (402.10) Egress (402.4) Kiosk requirements (402.11) Mall width (402.5) Playground structures (402.12) Unlimited area (402.6) Security grilles and doors (402.13) Fire separations (402.7) Standby power and emergency voice/alarm (402.14, 402.15) Interior finish (402.8) Plastic signs (402.16) Automatic sprinkler system (402.9) Standpipe system (402.9.1) Fire department access (402.17) -5- HIGH-RISE BUILDINGS (403) ATRIUMS (404) Construction (403.2) Automatic sprinkler system (403.3) Smoke detection (403.4.1) Fire alarm system (403.4.2) Emergency voice/alarm systems (403.4.3) Emergency responder radio coverage (403.4.4) Fire command center (403.4.5) Smoke removal (403.4.6) Elevators (403.6) Standby power (403.4.7) Emergency power (403.4.8) Stair remoteness (403.5.1) Additional stairway (403.5.2) Stairway doors (403.5.3) Smokeproof exit (403.5.4) Luminous egress path (403.5.5) Use (404.2) Automatic sprinkler system (404.3) Fire alarm system (404.4) Smoke control (404.5) Enclosure (404.6) Stariuvy power (404.7) Interior finish (404.8) Travel distance (404.9) OTHER SPECIAL USE AND OCCUPANCY Underground structures (405) Motor -vehicle -related occupancies (406, 509) Group 1-2 (407) Group 1-3 (408) Motion picture: ,projection rooms (409) Stages and platforms (410) Special amusement buildings (411) Aircraft -related occupancies (412) Combustible storage (413) Hazardous materials (307.1, 414) Groups H-1, H-2, H-3, H-4 and H-5 (415) Application of flammable finishes (416) Drying rooms (417) Organic coatings manufacturing (418) Live/work units (419) Groups 1-1, R-1, R-2, R-3 (420) Hydrogen cutoff rooms (421) Ambulatory health care facilities (422) Storm shelters (423) (FIRE PROTECTION (Chapters 6, 7, 8, 9) FIRE -RESISTANCE -RATED CONSTRUCTION (Tables 601 & 602 and Chapter 7) Note: Entry in ❑ indicates required rating in hours. NC indicates noncombustible construction required. FIRE -RESISTANCE RATINGS AND FIRE TESTS (703) Construction classification (602) Ratings / Combustibility (703.2, 703.4) COMBUSTIBILITY(602.2, 602.3, 602.4, 602.5, 603) Alternative methods (703.3, 718, 720, 721) Exterior walls Rated glazing (703.5) Interior elements Marking and identification (703.6) Roof 12 BUILDING ELEMENTS (Table 601) ❑ Structural frame (704) ❑ Interior bearing walls ❑ Interior nonbearing walls ❑ Floor construction (712) ❑ Roof construction (7.12) EXTERIOR WALLS (507, Table 602, 705, 707.4) North East South West Fire ' separation distance Bearing ❑ ❑ ❑ ❑ Nonbearing ❑ ❑ ❑ ❑ ❑ Opening protection (705.8.1 - 705.8.4) ❑ Vertical fire spread protection (705.8.5, 705.8.6) 0 Parapets (705.11) FIRE BARRIERS (707) ❑ Shaft enclosures (707.3.1) ❑ Exit enclosures/exit passageway . (707.3.2, 707.3.3) ❑ Horizontal exits (707.3.4) ❑ Atriums (707.3..5) ❑ yi Incidental accessory.occupancies (707.3.6) ❑ Control areas (707.3.7) ❑ Mixed occupancy and fire area separations (707..3.8, 707.3.9, 901.7) ❑ Construction (707.5 - 707.9) SHAFTS (708) ❑ Exceptions (708.2) ❑ Construction (708.3 - 708.12, 708.14) ❑ Refuse and laundry chutes (708.13) ❑ Elevator lobby (708.14.1, 708.14.2) OTHER FIRE-RESISTANT CONSTRUCTION ❑ Fire walls (706) ❑ Fire partitions (709) ❑ Smoke barriers (710) Smoke partitions (711) Penetrations (713) , Fire-resistant joint systems (714) Opening protectives (715) Dampers (716) Concealed spaces (717) Thermal- and sound -insulating materials (719, 807) INTERIOR FINISHES (Chapter 8) Smoke development (803.1.1, 803.9, Table 803.9) Flame spread (803.1.1, 803.9, Table 803.9) Textile/expanded vinyl coverings (803.1.2 - 803.1.4, 803.5 - 803.8) Floor finish (804) Combustible materials (805) Decorations and trim (806) Acoustical ceiling systems (808) -7- FIRE PROTECTION (Chapter 9) AUTOMATIC SPRINKLER SYSTEMS (903) (Where required) Assembly (A-1, A-2, A-3, A-4, A-5)• (903.2.1) Ambulatory health care facilities (B) (903.2.2) Educational (E) (903.2.3) Factory/Industrial (F-1) (903.2.4) High -hazard (H-1, H-2, H-3, H-4, H-5) (903: 2.5) Institutional (1-1, 1-2, 1-3, 1-4) (407.5, 903.2.6) Mercantile (M) (903.2..7) Residential (R) (903.2.8) Storage/Repair garage (S-1) (903.2.9) Parking garages (903.2.10) Windowless story (963.2.11.1) Rubbish and linen chutes (903.2.11.2) Buildings over 55 ft. high (903.2.11.3) Incidental accessory occupancies (Table 508.2.5) Additional required systems (Table 903.2.11.6) International Fire Code (IFC 903.2.11.6) AUTOMATIC SPRINKLER SYSTEMS* (903) (Design) Shop drawings (107.2.2) NFPA 13 system (903.3.1.1) NFPA 13R system (903.3.1.2) NFPA 13D system (903.3.1.3) Quick -response and residential heads (903.3.2) Actuation (903.3.4) Water supplies (903.3.5) Hose threads (903.3.6) Sprinkler monitoring and alarms (903.4) * Also see Fire Code Sprinkler Plan Review Record . ALTERNATIVE AUTOMATIC FIRE -EXTINGUISHING SYSTEMS (904) Installation (904.3) Wet -chemical systems (904.5) Dry -chemical systems (904.6) Foam systems (904.7) Carbon dioxide systems (904.8) Halon systems (904.9) Clean -agent systems (904.10) Commercial cooking systems (904.2.1, 904.11) STANDPIPE SYSTEMS (905) Installation standards (905.2) Building height (905.3.1) Group A (905.3.2) Covered malls (905.3.3) Stages (905.3.4) Underground buildings (905.3.5) Helistops/heliports (905.3.6) Marinas/boatyards (905.3.7) Hose connections and locations (905.1, 905.4, 905.5, 905.6) Cabinets (905.7) Dry standpipes (905.8) Valve supervision (905.9) PORTABLE FIRE EXTINGUISHERS (906) Required locations (906.1, 906.5, 906.6) Installation standard (906.2) Size and distribution (906.3) Cabinets (906.8) Installation (906.9) FIRE ALARM AND DETECTION SYSTEMS (907) (Where required) ' Construction documents/shop drawings (907.1.1, 907.1.2) Assembly (A-1, A-2, A-3, A-4, A-5) . (907.2.1) Business (B) (907.2.2) Educational (E) (907.2.3) Factory (F-1, F-2) (907.2.4) High -hazard (H-1, H-2, H-3, H-4, H-5) (907.2.5) Institutional (1-1, 1-2, 1-3, 1-4) (907.2.6) Mercantile (M) (907.2.7) Residential (R-1, R-2, R-4) (907.2.8, 907.2.9, 907.2.10) Single/multiple station smoke alarms (907.2.11) High-rise buildings (907.2.13) Atriums (907.2.14) Other buildings/areas (907.2.12, 907.2.15 - 907.2.23) FIRE ALARM AND DETECTION SYSTEMS (907) (Design) Residential smoke alarm interconnection (907.2.11.3) Residential smoke alarm power source (907.2.11.4) t Fire safety functions (907.3) Initiating devices (907.4) Occupant notification (907.5) Installation (907.6, 907.7) EMERGENCY ALARM SYSTEMS (908) Detection system applicable (908.1 - 908.6) SMOKE CONTROL SYSTEMS (909) Where required (402.10, 404.5, 405.5, 408.9, 410>3.7.2, 1022.9, 1028.6.2.1) Design requirements (909.1 - 909.4) Smoke barriers (909.5) Pressurization method (909.6) Airflow design method (909.7) Exhaust method (909.8) Design fire (909.9) Equipment/Power (909.10, 909.11) Detection and control (909.12 - 909.18) Smokeproof enclosures (909.20) SMOKE AND HEAT VENTS (910) Requirements (910.1 - 910.3) Mechanical alternative (910.4) FIRE COMMAND CENTER (911.) Requirements (911.1.1 - 911.1.5) FIRE DEPARTMENT CONNECTIONS (912) Installation (912.1 - 912.5) FIRE PUMPS (913) Requirements (913.1 913.5) EMERGENCY RESPONDER SAFETY FEATURES/ RADIO COVERAGE (914, 915) Requirements (914.1, 914.2, 915.1) go OCCUPANT NEEDS (Chapters 10, il, 112) MEANS OF EGRESS (Chapter 10) .00CUPANT LOAD (1004. 1. land Table 1004.1.1) CAPACITY OF EGRESS COMPONENTS (1005.1) Other egress Location Stairways components Floor Sq.ft.% _ Occt. Other Location Area person load occt. Total loads NUMBER OF EXITS (1021.1, 1021.2) Location Required Shown -10- MEANS OF EGRESS (continued) GENERAL MEANS OF EGRESS Design requirements (1003.2 - 1003.7) Door/Hardware encroachment (1005.2, 1005.3) Means of egress illumination (1006) Exit signs (1011) Accessible means of egress (1007) Means of egress doors (1008.1 - 1008.1.3) Special doors/Gates/Turnstiles (1008.1.4, 1008.2, 1008.3) EXIT ACCESS Door number and arrangement (1014.2, 1015.1, 1015.2) Common path of egress travel (1014.3) Exit access travel distance (1016.1) EXITS / EXIT DISCHARGE Exits/Exit doors (1020, 1021) Vertical exit enclosures (1022) Exit passageways (1023) Door landings/Thresholds/Arrangement (1008.1. 5 - 1008,1, 8) Door hardware (1008.1.9, 1008.1.10) Stairways (1009) Roof access (1009.13) Ramps (1010) Handrails (1012) Guards (1013) Luminous egress path markings (1024) Aisles (1017) Egress balconies . (1016.2, 1019) Corridors (1018) Air movement in corridors (1018.5) OTHER MEANS OF EGRESS Horizontal exits (1025) Exterior exit ramps/stairways (1026) Exit discharge (1027) Miscellaneous egress requirements Assembly aisles & features (1015.3 - 1015.6) (1028.6 - 1028.15) Bleachers (1028.1.1) Emergency escape and rescue (1029) Assembly exits & egress (1028.2 - 1028.5) ACCESSIBILITY* (Chapter 11) Scoping requirements (1103) Accessible route (1104) Accessible entrances (1105) Parking and passenger loading (1106) *Also see Accessibility Plan Review Record Dwelling units and sleeping units (1107) Special occupancies (1108) Features and facilities (1109) Signage (1110) -11- INTERIOR ENVIRONMENT (Chapter 12) Ventilation (1203)* Sound transmission (1207) Temperature control (1204) Interior space dimensions (1208) Lighting (1205) Access to unoccupied spaces (1209) Yards or courts (1206) Surrounding materials (1210, 2509) *Also see Mechanical Code Plan Review Record BUILDING ENVELOPE (Chapters 13*, 149 15) *See Energy Conservation Code Plan Review Record EXTERIOR WALLS (Chapter 14) Performance requirements (1403) Combustible material restrictions (1406) Materials (1404) EIFS (1408) Exterior wall coverings/MCM's (1405, 1407) ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (Chapter 15) Weather protection (1503) Materials (1506) Flashing (1503.2, 1507.2.9, 1507.3.9, Roof coverings (1507) 1507.5.7, 1507.7.7, 1507.6.8, 1507.9.9) Roof insulation (1508) Performance requirements (1504) Rooftop structures (1509) Fire classification (1505) Reroofing (1510) STRUCTURAL SYSTEMS (Ch-apters 16, 17,18) STRUCTURAL DESIGN (Chapter 16) STRUCTURAL DESIGN CALCULATIONS Submitted for all structural members (106, 107.1, 107.2.1, 1604, 1605) DESIGN LOADS ON CONSTRUCTION DOCUMENTS (1603) Uniformly distributed floor live loads (1603.1.1, Table 1607.1) Floor Area Use Loads Shown Live load reduction (1603.1.1, 1667.9, 1607.10) Roof live loads (1603.1.2, 1607.11) Roof snow loads (1603.1.3, 1608; Chapter 7 of ASCE 7) Ground snow load, pg (1608.2, 7.2 of ASCE 7) If pg > 10 psf, flat -roof snow load, pf (7.3 of ASCE 7) If pg > 10 psf, snow exposure factor, Ce (Table 7-2, 7.3.1 of ASCE 7) If pg > 10 psf, snow load importance factor, 1(7.3.3, Table 7-4 of ASCE 7) If pg > 10 psf, roof thermal factor, Ct (Table 7-3, 7.3.2 of ASCE 7) Sloped roof snow load, ps (7.4 of ASCE 7) -12- DESIGN LOADS (continued) \ Wind loads (1603.1.4, 1609; Chapter 6 of ASCE 7) Design procedure (1609.6, 6.1.2 of ASCE 7) Alternate all -heights method (1609.6) Basic wind speed (1609.3, Fig. 6-1 of ASCE 7) Occupancy category (Table 1604.5, Table 14 of ASCE 7) Wind importance factor, / (Table 6-1, 6.5.5 of ASCE 7) Surface roughness/Exposure categories (1609.4, 6.5. 6 of ASCE 7) Internal pressure coefficient (Fig. 6-5, 6.5.11.1 of ASCE 7) Component and cladding pressures (6.1.4.2, 6.4.2.2, 6.5.12.4 of ASCE 7) Main wind -force resisting system (6.1.4.1, 6.4.2.1, 6.5.12.2 of ASCE 7) Earthquake design data (1603.1.5, 1613; Chapter 11- 13 and 15 - 23 of ASCE 7) Occupancy category . (Table 1604.5, Table 1-1 of ASCE 7) Seismic importance factor (11.5.1, Table 11.5-1 of ASCE 7) Mapped spectral response acceleration, Ss and SI (1613.5.1; 11.4.1 of ASCE 7) Spect,I:sponse coefficients, Sps & SDI (1613.5.4; 11.4.4 of ASCE 7) Site class (1613.5.2, 11.4.2 of ASCE 7) Seismic design category (1613.5.6, 11.6 of ASCE 7) Basic seismic -force -resisting system (Table 12.2-1 of ASCE 7) Response modification coefficient, R, and deflection amplification factor, Cd (Table 12.2-1 of ASCE 7) Analysis procedure (12.6 of ASCE 7) Design base shear (12.8 of ASCE 7) Flood loads (1603.1.7, 1612) Other loads Flood hazard area (1612.3) Elevation of structure (1612.5) Concentrated loads (1607.4) Partition loads (1607.5) Impact loads (1607.8) Misc. loads (Table 1607.6, 1607.6.1, 1607.7, 1607.12, 1607.13, 1610, 1611, 2404) Structural integrity (1614) Design requirements (1614.1 - 1614.4) QUALITY ASSURANCE (Chapter 17) Approvals/Research report(s)(1703, Sprayed fire-resistant materials and 1703.4.2) Report No. coatings (1704.12, 1704.13) Statement of special inspections EIFS (1704.14) (1704.1.1, 1705) Smoke control (1704.16) Prefabricated items ,(1704.2) Steel construction (1704.3) Concrete construction (1704.4) Masonry construction (1704.5) Wood construction (1704.6) Prepared fill and foundations (1704.7 - 1704.11) Wind requirements (1706) Seismic resistance (1707) Contractor responsibility (1709) Structural testing/Observations (seismic) (1708, 1710) Testing (other) (1711 - 1716) SOILS ARID FOUNDATIONS (Chapter 18) Soils investigations/Reports Foundation walls, retaining walls and (1803.1, 1803.2, 1803.3, 1803.6) embedded posts and poles (1807) Soil classification (1803.5) Foundations (1808) Excavation, grading and fill (1804) Shallow foundations (1809) Dampproofing and waterproofing (1805) Deep foundations (1810) Load -bearing values (1603.1.6, 1806) -13- STRUCTURAL MATEMALS (Chapters 19, 21, 22, 23) CONCRETE (Chapter 19) Plain and reinforced concrete Minimum concrete strength design/construction standard (Table 1904.3) specified (1901.2, 1908) Cold weather and hot weather construc- Construction documents (1901.4) tion specified (1905.12, 1905.13) Slab provisions (1910) MASONRY (Chapter 21) Design method, construction standard Cold weather and hot weather construc- specified (2101.2) tion specified (2104.3, 2104.4) Construction documents (2101.3) Seismic design (2106) Construction materials (2103) Glass unit masonry'(2110) Mortar type (2103.8) Fireplaces/Heaters/Chimneys (2101.3.1, 2111, 2112, 2113) STEEL (Chapter 22) Structural steel design/construction Steel storage racks (2208) standard specified (2205) Cold -formed steel design/construction Open -web steel joist design/construction standard specified (2209) standard specified (2206) Cold -formed steel light -framed design/ Steel cable structures (2207) construction standard -specified (2210) WOOD (Chapter 23) ' Design method option used (2301.2) MATERIAL STANDARDS / CONSTRUCTION REQUIREMENTS (2303 - 2306) Lumber (2303.1.1) Wood I -joists (2303.1.2) Glue -laminated timbers (2303.1.3) Wood structural panels (2303.1.4, 2304.6, 2304.7) Fiber-, hard-, & particle-, boards (2303.1.5 - 2303.1.7) Decay and termite protection (2303.1.8, 2304.11) Structural composite lumber (2303.1.9) Structural log members (2303.1.10) Round timber poles and piles (2303.1.11) Fire -retardant -treated wood (2303.2) Hardwood and plywood (2303.3) Trusses (2303.4) Joist hangers and connectors (2303.5) Fasteners and fastening . (2303.6, 2304.9, Table 2304.9.1) Heavy timber construction (2304.10) Shear walls and diaphragms (2305, 2306) CONVENTIONAL LIGHT -FRAME CONSTRUCTION (2308) Limitations satisfied (2308.2) Wind/Seismic requirements (2368.2.1, 2308.2.2, 2308.11, 2308.12) Braced walls (2308.3, 2308.9.3) Foundation anchorage (2308.3.3, 2308.6) Floor joists (Tables 2308.8(1], 2308.8[2]) Wall studs (Table 2308.9.1) Girders (Tables 2308.9.5 and 2308,9.6, 2308.7) Ceiling joists (Tables 2308.10.2[1], 2308.10.2j2]) Roof rafters (Tables 2308.10.3.[1] - 2308.10.3[6]) Roof uplift (2308.10.1) -14- NONSTRUCT�U-dAL MATERIALS (Chapte ;5 24, 25, 25) GLASS AND GLAZING (Chapter 24) .Sloped glazing and skylights (2405) Safety glazing (2406, 2407, 2408, 2409) GYPSUM BOARD AND PLASTER (Chapter 25) Gypsum board materials (2506, Table 2506.2, Table 2508.1) PLASTIC (Chapter 26) FOAM PLASTIC INSULATION (2603) Labeling (2603.Z 2603.5.6) Surface -burning characteristics (2603.3, 2603.5.4) Thermal barrier (2603.4) Exterior walls/Roofs (2603.5, 2603.6) Protection against termites (2603.8) Plaster (2507, 2508, 2510 - 2513) Special approval (2603.9) MISCELLANEOUS PLASTICS Interior finish and trim (2604) Plastic veneer (2605) Light -transmitting plastics (2606 - 2611) Fiber reinforced and fiberglass reinforced polymer (2612) BUILDING SERVICES* (Chapters 27, 28, 29, 30) ELEVATORS AND CONVEYING SYSTEMS (Chapter 30) Construction standard specified (3001.2) Conveying systems (3005) Hoistway enclosures (3002) Machine rooms (3006) .Opening protectives (3002.1.1) Fire service access elevator (3007) Emergency operations (3003) Occupant evacuation elevator (3008) Hoistway venting (3004) * Also see Electrical (Ch.27), Mechanical (Ch.28) and Plumbing (Ch.29) Plan Review Records SPECIAL DEVICES AND CONDITIONS (Chapters 31, 34) SPECIAL CONSTRUCTION (Chapter 31) Membrane structures (3102). Temporary structures (3103) Awnings and canopies/Marquees (3105, 3106) Signs (3107) Telecommunication and broadcast towers (3108) Swimming pool enclosures (3109) Automatic vehicular gates (3110) PEDESTRIAN WALKWAYS AND TUNNELS (3104) Construction and use (3104.3, 3104.4) Separation (3104.5, 3104,10) Public way (3104.6) Egress (3104.7 - 3104.9) EXISTING STRUCTURES (Chapter 34) Building materials (3401.4) Change of occupancy (3408) Additions, alterations, repairs Accessibility (3411) (3403 - 3405) Compliance alternatives (3412) Fire escapes (3406) -15- BUILDING EVALUATION SUMMARY (Table 3412.7) Existing occupancy: Proposed occupancy: Year building was constructed: Number of stories: Height in feet: Type of construction: Area per floor: Percentage of open perimeter increase: % Corridor wall rating: Completely suppressed: Yes No Required door closers: Yes No Compartmentation: Yes No Fire -resistance rating of vertical opening enclosures: Type of HVAC system: serving number of floors: Automatic fire detection: Yes No type and location: Fire alarm system: Yes No type: - Smoke control: Yes No type: Adequate exit routes: Yes No Dead ends: Yes No Maximum exit access travel distance: Elevator controls: YesNo Means of egress emergency lighting: Yes No Mixed occupancies: Yes No Safety parameters Fire Means General safety (FS) of egress (ME) safety (GS) 3412.6.1 Building height 3412.6.2 Building area 3412.6.3 Compartmentation 3412.6.4 Tenant and dwelling unit separations 3412.6.5 Corridor walls 3412.6.6 Vertical openings 3412.6.7 HVAC systems 3412.6.8 Automatic fire detection 3412.6.9 Fire alarm system 3412.6.10 Smoke control 3412.6.11 Means of egress capacity 3412.6.12 Dead ends 3412.6.13 Max, exit access travel distance 3412.6.14 Elevator control 3412.6.15 Means of egress emergency lighting 3412.6.16 Mixed occupancies 3412.6.17 Automatic sprinklers - 2 = 3412.6.18 Standpipes 3412.6.19 Incidental accessory occupancy Building score — total value No applicable value to be inserted. BUILDING SAFETY EVALUATION SCORE (Table 3412.9) Formula Table 3412.7 Table 3412.8 Score Pass Fail FS—MFS >_ 0 (FS) — (MFS) = ME—MME >_ 0 (ME) — (MME) = GS—MGS >_ 0 (GS) — (MGS) = FS = Fire Safety MFS = Mandatory Fire Safety ME = Means of Egress MME = Mandatory Means of Egress GS = General Safety MGS = Mandatory General Safety APPENDICES A - K Appendices adopted (101.2.1) Compliance verified -16-