CORRECTION LIST (cont'd.)
Code
No. DESCRIPTION Section
-2-
-CORRECTION LIST (cont'd.)
Code
No. DESCRIPTION Section
'3-
NOTES: N.R. —Not required
N.A. — Not applicable
ADMNSTRAMN. (Chapter 1)
Complete construction documents Signed/sealed construction documents
(107.1, 107.2) (107.1, State laws vary)
BMDING PLANNNG (Chapters 3, 4, 5, 6)
OCCUPANCY CLASSIFICATION (302 - 3'12, 508)
ZSingle Occupancy (302.1) Incidental accessory occupancies
Mixed Occupancy (508,1) (5082.5, Table 508.2.5)
Accessory occupancies (508.2)
GENERAL BUILDING LIMITATIONS (Chapters 5 & 6)
Address identification (501.2)
Apply Case 1 to determine the allowable height and area and permitted types of construction for a building containing a
single occupancy or nonseparated mixed occupancies. Apply Case 2 to determine the allowable height and area and
permitted types of construction for a building containing separated mixed occupancies.
AREA MODIFICATIONS TO TABLE 503
Allowable tabular area, At (Table 503) 1
Area Increase Factor due
to frontage, If (506.2) +
Area Increase Factor due to
automatic sprinklers, Is (506.3) +
Conversion factor =
Frontage
(506.2)
North East South West
Total
Frontage
Width of open space (W) _
Area Increase Factor
due to frontage, It=
(506.2)
Perimeter (P) ft.
If = CP — 0.25] W
CASE 1 — SINGLE OCCUPANCY OR NONSEPARATED MIXED OCCUPANCIES (508.3)
Using Table 503, identify the allowable height and area of the single occupancy or the most restrictive of the nonseparated
mixed occupancies. Construction types that provide an allowable tabular area equal to or greater than the adjusted building
area and allowable heights (as modified by Section 504) equal to or greater than the actual building height are permitted.
DETERMINE CONSTRUCTION TYPE CHECK ALLOWABLE AREA (506.4)
Actual building area
Allowable area per floor (Aa)
Adjusted building area ft2 X = ft2
actual building area _ conversion factor conversion factor tabular area (Table 503)
Actual building height feet stories Total floor area (all stories) ft2
Allowable building height
Permitted types of construction
Type of construction assumed
for review (602.1)
feet stories Allowable floor area (all stories)
X = ft2
Allowable area per floor number of stories
(AJ (maximum 3)
Compliance verified
-4-
'
F
CASE 2 —SEPARATED MIXED OCCUPANCIES (508.4)
Using Table 503, identify the allowable height and area of each of the separated occupancies within the building. Construc-
tion types that provide, for each story of the building, tabular areas (as modified by Section 506) which result in a surn of the
ratios of 1.00 or less and allowable heights (as modified by Section 504) equal to or greater than the actual height of the
occupancy are permitted.
Actual Adjusted
Actual Allowable .
Story Group floor area floor area*
height height
ft2 ft2
ft stories ft stories
ft2 ft2
ft stories ft stories
ft2 ff
ft stories ft stories
ft2 ft2
ft stories.. ft stories
ft2 ft2
ft stories ft stories
ft2 ft2
ft stories ft -stories
ft2 ft2
ft stories ft stories
Adjusted floor area
Area ratio (single floor)=
+ + + _ _<100
Allow. tab. area, A, (Table 503)
*Adjusted floor area = actual floor area = conversion factor"
CHECK ALLOWABLE AREA (506.5)
Permitted types -of construction
Three stories or less buildings
Type of construction assumed
for review (602..1)
Four or more story buildings
(Total area ratio < 3)
Compliance verified
MEZZANINES
(505)
Area limitation (505.2)
Openness (505.4)
Egress (505.3)
Equipment platforms (505.5)
UNLIMITED AREA BUILDINGS (507)
Nonsprinklered, one story (507.2)
Group H occupancies (507.8)
Sprinklered, one story (507.3)
Aircraft paint hangar (507.9)
Two story (507.4)
Group E buildings (507.10)
Reduced open -space (507.5)
Motion picture theaters (507.11)
Group A-3 buildings (507.6, 507.7)
Covered mall buildings/anchor stores .
(507.12)
SPECIAL PROVISIONS (509)
Special condition applicable (509.1)
Compliance verified
SPECIAL DETAILED REQUIREMENTS EASED ON USE AND OCCUPANCY (Chapter 4)
COVERED MALL AND OPEN MALL BUILDINGS (402)
Smoke control (402.10)
Egress (402.4)
Kiosk requirements (402.11)
Mall width (402.5)
Playground structures (402.12)
Unlimited area (402.6)
Security grilles and doors (402.13)
Fire separations (402.7)
Standby power and emergency
voice/alarm (402.14, 402.15)
Interior finish (402.8)
Plastic signs (402.16)
Automatic sprinkler system (402.9)
Standpipe system (402.9.1)
Fire department access (402.17)
-5-
HIGH-RISE BUILDINGS (403)
ATRIUMS (404)
Construction (403.2)
Automatic sprinkler system (403.3)
Smoke detection (403.4.1)
Fire alarm system (403.4.2)
Emergency voice/alarm systems
(403.4.3)
Emergency responder radio coverage
(403.4.4)
Fire command center (403.4.5)
Smoke removal (403.4.6)
Elevators (403.6)
Standby power (403.4.7)
Emergency power (403.4.8)
Stair remoteness (403.5.1)
Additional stairway (403.5.2)
Stairway doors (403.5.3)
Smokeproof exit (403.5.4)
Luminous egress path (403.5.5)
Use (404.2)
Automatic sprinkler system (404.3)
Fire alarm system (404.4)
Smoke control (404.5)
Enclosure (404.6)
Stariuvy power (404.7)
Interior finish (404.8)
Travel distance (404.9)
OTHER SPECIAL USE AND OCCUPANCY
Underground structures (405)
Motor -vehicle -related occupancies
(406, 509)
Group 1-2 (407)
Group 1-3 (408)
Motion picture: ,projection rooms (409)
Stages and platforms (410)
Special amusement buildings (411)
Aircraft -related occupancies (412)
Combustible storage (413)
Hazardous materials (307.1, 414)
Groups H-1, H-2, H-3, H-4 and H-5
(415)
Application of flammable finishes (416)
Drying rooms (417)
Organic coatings manufacturing (418)
Live/work units (419)
Groups 1-1, R-1, R-2, R-3 (420)
Hydrogen cutoff rooms (421)
Ambulatory health care facilities (422)
Storm shelters (423)
(FIRE PROTECTION (Chapters 6, 7, 8, 9)
FIRE -RESISTANCE -RATED CONSTRUCTION (Tables 601 & 602 and Chapter 7)
Note: Entry in ❑ indicates required rating in hours. NC
indicates noncombustible construction required. FIRE -RESISTANCE RATINGS AND FIRE TESTS (703)
Construction classification (602) Ratings / Combustibility (703.2, 703.4)
COMBUSTIBILITY(602.2, 602.3, 602.4, 602.5, 603) Alternative methods
(703.3, 718, 720, 721)
Exterior walls
Rated glazing (703.5)
Interior elements
Marking and identification (703.6)
Roof
12
BUILDING
ELEMENTS (Table 601)
❑
Structural frame (704)
❑
Interior bearing walls
❑
Interior nonbearing walls
❑
Floor construction (712)
❑
Roof construction (7.12)
EXTERIOR WALLS (507, Table 602, 705, 707.4)
North East South West
Fire '
separation
distance
Bearing ❑ ❑ ❑ ❑
Nonbearing ❑ ❑ ❑ ❑
❑ Opening protection
(705.8.1 - 705.8.4)
❑ Vertical fire spread protection
(705.8.5, 705.8.6)
0 Parapets (705.11)
FIRE BARRIERS (707)
❑
Shaft enclosures (707.3.1)
❑
Exit enclosures/exit passageway .
(707.3.2, 707.3.3)
❑
Horizontal exits (707.3.4)
❑
Atriums (707.3..5)
❑
yi
Incidental accessory.occupancies
(707.3.6)
❑
Control areas (707.3.7)
❑
Mixed occupancy and fire area
separations (707..3.8, 707.3.9, 901.7)
❑
Construction (707.5 - 707.9)
SHAFTS (708)
❑
Exceptions (708.2)
❑
Construction (708.3 - 708.12, 708.14)
❑
Refuse and laundry chutes (708.13)
❑
Elevator lobby (708.14.1, 708.14.2)
OTHER FIRE-RESISTANT CONSTRUCTION
❑
Fire walls (706)
❑
Fire partitions (709)
❑
Smoke barriers (710)
Smoke partitions (711)
Penetrations (713) ,
Fire-resistant joint systems (714)
Opening protectives (715)
Dampers (716)
Concealed spaces (717)
Thermal- and sound -insulating materials
(719, 807)
INTERIOR FINISHES (Chapter 8)
Smoke development (803.1.1, 803.9,
Table 803.9)
Flame spread (803.1.1, 803.9,
Table 803.9)
Textile/expanded vinyl coverings
(803.1.2 - 803.1.4, 803.5 - 803.8)
Floor finish (804)
Combustible materials (805)
Decorations and trim (806)
Acoustical ceiling systems (808)
-7-
FIRE PROTECTION (Chapter 9)
AUTOMATIC SPRINKLER SYSTEMS (903)
(Where required)
Assembly (A-1, A-2, A-3, A-4, A-5)•
(903.2.1)
Ambulatory health care facilities (B)
(903.2.2)
Educational (E) (903.2.3)
Factory/Industrial (F-1) (903.2.4)
High -hazard (H-1, H-2, H-3, H-4, H-5)
(903: 2.5)
Institutional (1-1, 1-2, 1-3, 1-4)
(407.5, 903.2.6)
Mercantile (M) (903.2..7)
Residential (R) (903.2.8)
Storage/Repair garage (S-1) (903.2.9)
Parking garages (903.2.10)
Windowless story (963.2.11.1)
Rubbish and linen chutes (903.2.11.2)
Buildings over 55 ft. high (903.2.11.3)
Incidental accessory occupancies
(Table 508.2.5)
Additional required systems
(Table 903.2.11.6)
International Fire Code
(IFC 903.2.11.6)
AUTOMATIC SPRINKLER SYSTEMS* (903)
(Design)
Shop drawings (107.2.2)
NFPA 13 system (903.3.1.1)
NFPA 13R system (903.3.1.2)
NFPA 13D system (903.3.1.3)
Quick -response and residential heads
(903.3.2)
Actuation (903.3.4)
Water supplies (903.3.5)
Hose threads (903.3.6)
Sprinkler monitoring and alarms
(903.4)
* Also see Fire Code Sprinkler Plan Review Record .
ALTERNATIVE AUTOMATIC FIRE -EXTINGUISHING
SYSTEMS (904)
Installation (904.3)
Wet -chemical systems (904.5)
Dry -chemical systems (904.6)
Foam systems (904.7)
Carbon dioxide systems (904.8)
Halon systems (904.9)
Clean -agent systems (904.10)
Commercial cooking systems
(904.2.1, 904.11)
STANDPIPE SYSTEMS (905)
Installation standards (905.2)
Building height (905.3.1)
Group A (905.3.2)
Covered malls (905.3.3)
Stages (905.3.4)
Underground buildings (905.3.5)
Helistops/heliports (905.3.6)
Marinas/boatyards (905.3.7)
Hose connections and locations
(905.1, 905.4, 905.5, 905.6)
Cabinets (905.7)
Dry standpipes (905.8)
Valve supervision (905.9)
PORTABLE FIRE EXTINGUISHERS (906)
Required locations
(906.1, 906.5, 906.6)
Installation standard (906.2)
Size and distribution (906.3)
Cabinets (906.8)
Installation (906.9)
FIRE ALARM AND DETECTION SYSTEMS (907)
(Where required) '
Construction documents/shop drawings
(907.1.1, 907.1.2)
Assembly (A-1, A-2, A-3, A-4, A-5) .
(907.2.1)
Business (B) (907.2.2)
Educational (E) (907.2.3)
Factory (F-1, F-2) (907.2.4)
High -hazard (H-1, H-2, H-3, H-4, H-5)
(907.2.5)
Institutional (1-1, 1-2, 1-3, 1-4) (907.2.6)
Mercantile (M) (907.2.7)
Residential (R-1, R-2, R-4) (907.2.8,
907.2.9, 907.2.10)
Single/multiple station smoke alarms
(907.2.11)
High-rise buildings (907.2.13)
Atriums (907.2.14)
Other buildings/areas
(907.2.12, 907.2.15 - 907.2.23)
FIRE ALARM AND DETECTION SYSTEMS (907)
(Design)
Residential smoke alarm
interconnection (907.2.11.3)
Residential smoke alarm power source
(907.2.11.4)
t
Fire safety functions (907.3)
Initiating devices (907.4)
Occupant notification (907.5)
Installation (907.6, 907.7)
EMERGENCY ALARM SYSTEMS (908)
Detection system applicable
(908.1 - 908.6)
SMOKE CONTROL SYSTEMS (909)
Where required (402.10, 404.5, 405.5,
408.9, 410>3.7.2, 1022.9, 1028.6.2.1)
Design requirements (909.1 - 909.4)
Smoke barriers (909.5)
Pressurization method (909.6)
Airflow design method (909.7)
Exhaust method (909.8)
Design fire (909.9)
Equipment/Power (909.10, 909.11)
Detection and control (909.12 - 909.18)
Smokeproof enclosures (909.20)
SMOKE AND HEAT VENTS (910)
Requirements (910.1 - 910.3)
Mechanical alternative (910.4)
FIRE COMMAND CENTER (911.)
Requirements (911.1.1 - 911.1.5)
FIRE DEPARTMENT CONNECTIONS (912)
Installation (912.1 - 912.5)
FIRE PUMPS (913)
Requirements (913.1 913.5)
EMERGENCY RESPONDER SAFETY FEATURES/
RADIO COVERAGE (914, 915)
Requirements (914.1, 914.2, 915.1)
go
OCCUPANT NEEDS (Chapters 10, il, 112)
MEANS OF EGRESS (Chapter 10)
.00CUPANT LOAD (1004. 1. land Table 1004.1.1) CAPACITY OF EGRESS COMPONENTS (1005.1)
Other egress
Location Stairways components
Floor Sq.ft.% _ Occt. Other
Location Area person load occt. Total
loads
NUMBER OF EXITS (1021.1, 1021.2)
Location Required Shown
-10-
MEANS OF EGRESS (continued)
GENERAL MEANS OF EGRESS
Design requirements
(1003.2 - 1003.7)
Door/Hardware encroachment (1005.2,
1005.3)
Means of egress illumination (1006)
Exit signs (1011)
Accessible means of egress (1007)
Means of egress doors (1008.1 -
1008.1.3)
Special doors/Gates/Turnstiles
(1008.1.4, 1008.2, 1008.3)
EXIT ACCESS
Door number and arrangement (1014.2,
1015.1, 1015.2)
Common path of egress travel (1014.3)
Exit access travel distance
(1016.1)
EXITS / EXIT DISCHARGE
Exits/Exit doors (1020, 1021)
Vertical exit enclosures (1022)
Exit passageways (1023)
Door landings/Thresholds/Arrangement
(1008.1. 5 - 1008,1, 8)
Door hardware (1008.1.9, 1008.1.10)
Stairways (1009)
Roof access (1009.13)
Ramps (1010)
Handrails (1012)
Guards (1013)
Luminous egress path markings (1024)
Aisles (1017)
Egress balconies
. (1016.2, 1019)
Corridors (1018)
Air movement in corridors (1018.5)
OTHER MEANS OF EGRESS
Horizontal exits (1025)
Exterior exit ramps/stairways (1026)
Exit discharge (1027)
Miscellaneous egress requirements Assembly aisles & features
(1015.3 - 1015.6) (1028.6 - 1028.15)
Bleachers (1028.1.1) Emergency escape and rescue (1029)
Assembly exits & egress
(1028.2 - 1028.5)
ACCESSIBILITY* (Chapter 11)
Scoping requirements (1103)
Accessible route (1104)
Accessible entrances (1105)
Parking and passenger loading (1106)
*Also see Accessibility Plan Review Record
Dwelling units and sleeping units (1107)
Special occupancies (1108)
Features and facilities (1109)
Signage (1110)
-11-
INTERIOR ENVIRONMENT (Chapter 12)
Ventilation (1203)* Sound transmission (1207)
Temperature control (1204) Interior space dimensions (1208)
Lighting (1205) Access to unoccupied spaces (1209)
Yards or courts (1206) Surrounding materials (1210, 2509)
*Also see Mechanical Code Plan Review Record
BUILDING ENVELOPE (Chapters 13*, 149 15)
*See Energy Conservation Code Plan Review Record
EXTERIOR WALLS (Chapter 14)
Performance requirements (1403) Combustible material restrictions (1406)
Materials (1404) EIFS (1408)
Exterior wall coverings/MCM's (1405,
1407)
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (Chapter 15)
Weather protection (1503) Materials (1506)
Flashing (1503.2, 1507.2.9, 1507.3.9, Roof coverings (1507)
1507.5.7, 1507.7.7, 1507.6.8, 1507.9.9)
Roof insulation (1508)
Performance requirements (1504)
Rooftop structures (1509)
Fire classification (1505)
Reroofing (1510)
STRUCTURAL SYSTEMS (Ch-apters 16, 17,18)
STRUCTURAL DESIGN (Chapter 16)
STRUCTURAL DESIGN CALCULATIONS
Submitted for all structural members
(106, 107.1, 107.2.1, 1604, 1605)
DESIGN LOADS ON CONSTRUCTION DOCUMENTS
(1603)
Uniformly distributed floor live loads (1603.1.1,
Table 1607.1)
Floor Area Use Loads Shown
Live load reduction
(1603.1.1, 1667.9, 1607.10)
Roof live loads (1603.1.2, 1607.11)
Roof snow loads (1603.1.3, 1608; Chapter 7 of ASCE 7)
Ground snow load, pg (1608.2, 7.2 of
ASCE 7)
If pg > 10 psf, flat -roof snow load, pf (7.3 of
ASCE 7)
If pg > 10 psf, snow exposure factor, Ce
(Table 7-2, 7.3.1 of ASCE 7)
If pg > 10 psf, snow load importance
factor, 1(7.3.3, Table 7-4 of ASCE 7)
If pg > 10 psf, roof thermal factor, Ct (Table
7-3, 7.3.2 of ASCE 7)
Sloped roof snow load, ps (7.4 of ASCE 7)
-12-
DESIGN LOADS (continued) \
Wind loads (1603.1.4, 1609; Chapter 6 of ASCE 7)
Design procedure (1609.6, 6.1.2 of
ASCE 7)
Alternate all -heights method (1609.6)
Basic wind speed (1609.3, Fig. 6-1 of
ASCE 7)
Occupancy category
(Table 1604.5, Table 14 of ASCE 7)
Wind importance factor, / (Table 6-1,
6.5.5 of ASCE 7)
Surface roughness/Exposure categories
(1609.4, 6.5. 6 of ASCE 7)
Internal pressure coefficient (Fig. 6-5,
6.5.11.1 of ASCE 7)
Component and cladding pressures
(6.1.4.2, 6.4.2.2, 6.5.12.4 of ASCE 7)
Main wind -force resisting system
(6.1.4.1, 6.4.2.1, 6.5.12.2 of ASCE 7)
Earthquake design data (1603.1.5, 1613; Chapter 11- 13
and 15 - 23 of ASCE 7)
Occupancy category
. (Table 1604.5, Table 1-1 of ASCE 7)
Seismic importance factor (11.5.1, Table
11.5-1 of ASCE 7)
Mapped spectral response acceleration,
Ss and SI (1613.5.1; 11.4.1 of ASCE 7)
Spect,I:sponse coefficients, Sps &
SDI (1613.5.4; 11.4.4 of ASCE 7)
Site class (1613.5.2, 11.4.2 of ASCE 7)
Seismic design category (1613.5.6, 11.6
of ASCE 7)
Basic seismic -force -resisting system
(Table 12.2-1 of ASCE 7)
Response modification coefficient, R,
and deflection amplification factor, Cd
(Table 12.2-1 of ASCE 7)
Analysis procedure (12.6 of ASCE 7)
Design base shear (12.8 of ASCE 7)
Flood loads (1603.1.7, 1612)
Other loads
Flood hazard area (1612.3)
Elevation of structure (1612.5)
Concentrated loads (1607.4)
Partition loads (1607.5)
Impact loads (1607.8)
Misc. loads (Table 1607.6, 1607.6.1,
1607.7, 1607.12, 1607.13, 1610,
1611, 2404)
Structural integrity (1614)
Design requirements (1614.1 - 1614.4)
QUALITY ASSURANCE (Chapter 17)
Approvals/Research report(s)(1703, Sprayed fire-resistant materials and
1703.4.2) Report No. coatings (1704.12, 1704.13)
Statement of special inspections EIFS (1704.14)
(1704.1.1, 1705) Smoke control (1704.16)
Prefabricated items ,(1704.2)
Steel construction (1704.3)
Concrete construction (1704.4)
Masonry construction (1704.5)
Wood construction (1704.6)
Prepared fill and foundations
(1704.7 - 1704.11)
Wind requirements (1706)
Seismic resistance (1707)
Contractor responsibility (1709)
Structural testing/Observations (seismic)
(1708, 1710)
Testing (other) (1711 - 1716)
SOILS ARID FOUNDATIONS (Chapter 18)
Soils investigations/Reports Foundation walls, retaining walls and
(1803.1, 1803.2, 1803.3, 1803.6) embedded posts and poles (1807)
Soil classification (1803.5) Foundations (1808)
Excavation, grading and fill (1804) Shallow foundations (1809)
Dampproofing and waterproofing (1805) Deep foundations (1810)
Load -bearing values (1603.1.6, 1806)
-13-
STRUCTURAL MATEMALS (Chapters 19, 21, 22, 23)
CONCRETE (Chapter 19)
Plain and reinforced concrete
Minimum concrete strength
design/construction standard
(Table 1904.3)
specified (1901.2, 1908)
Cold weather and hot weather construc-
Construction documents (1901.4)
tion specified (1905.12, 1905.13)
Slab provisions (1910)
MASONRY (Chapter 21)
Design method, construction standard
Cold weather and hot weather construc-
specified (2101.2)
tion specified (2104.3, 2104.4)
Construction documents (2101.3)
Seismic design (2106)
Construction materials (2103)
Glass unit masonry'(2110)
Mortar type (2103.8)
Fireplaces/Heaters/Chimneys
(2101.3.1, 2111, 2112, 2113)
STEEL (Chapter 22)
Structural steel design/construction
Steel storage racks (2208)
standard specified (2205)
Cold -formed steel design/construction
Open -web steel joist design/construction
standard specified (2209)
standard specified (2206)
Cold -formed steel light -framed design/
Steel cable structures (2207)
construction standard -specified (2210)
WOOD (Chapter 23) '
Design method option used (2301.2)
MATERIAL STANDARDS / CONSTRUCTION
REQUIREMENTS (2303 - 2306)
Lumber (2303.1.1)
Wood I -joists (2303.1.2)
Glue -laminated timbers (2303.1.3)
Wood structural panels
(2303.1.4, 2304.6, 2304.7)
Fiber-, hard-, & particle-, boards
(2303.1.5 - 2303.1.7)
Decay and termite protection
(2303.1.8, 2304.11)
Structural composite lumber (2303.1.9)
Structural log members (2303.1.10)
Round timber poles and piles
(2303.1.11)
Fire -retardant -treated wood (2303.2)
Hardwood and plywood (2303.3)
Trusses (2303.4)
Joist hangers and connectors (2303.5)
Fasteners and fastening .
(2303.6, 2304.9, Table 2304.9.1)
Heavy timber construction (2304.10)
Shear walls and diaphragms
(2305, 2306)
CONVENTIONAL LIGHT -FRAME CONSTRUCTION
(2308)
Limitations satisfied (2308.2)
Wind/Seismic requirements (2368.2.1,
2308.2.2, 2308.11, 2308.12)
Braced walls (2308.3, 2308.9.3)
Foundation anchorage
(2308.3.3, 2308.6)
Floor joists (Tables 2308.8(1], 2308.8[2])
Wall studs (Table 2308.9.1)
Girders (Tables 2308.9.5 and 2308,9.6,
2308.7)
Ceiling joists (Tables 2308.10.2[1],
2308.10.2j2])
Roof rafters (Tables 2308.10.3.[1] -
2308.10.3[6])
Roof uplift (2308.10.1)
-14-
NONSTRUCT�U-dAL MATERIALS (Chapte ;5 24, 25, 25)
GLASS AND GLAZING (Chapter 24)
.Sloped glazing and skylights (2405) Safety glazing (2406, 2407, 2408, 2409)
GYPSUM BOARD AND PLASTER (Chapter 25)
Gypsum board materials
(2506, Table 2506.2, Table 2508.1)
PLASTIC (Chapter 26)
FOAM PLASTIC INSULATION (2603)
Labeling (2603.Z 2603.5.6)
Surface -burning characteristics
(2603.3, 2603.5.4)
Thermal barrier (2603.4)
Exterior walls/Roofs (2603.5, 2603.6)
Protection against termites (2603.8)
Plaster (2507, 2508, 2510 - 2513)
Special approval (2603.9)
MISCELLANEOUS PLASTICS
Interior finish and trim (2604)
Plastic veneer (2605)
Light -transmitting plastics (2606 - 2611)
Fiber reinforced and fiberglass
reinforced polymer (2612)
BUILDING SERVICES* (Chapters 27, 28, 29, 30)
ELEVATORS AND CONVEYING SYSTEMS (Chapter 30)
Construction standard specified (3001.2)
Conveying systems (3005)
Hoistway enclosures (3002)
Machine rooms (3006)
.Opening protectives (3002.1.1)
Fire service access elevator (3007)
Emergency operations (3003)
Occupant evacuation elevator (3008)
Hoistway venting (3004)
* Also see Electrical (Ch.27), Mechanical (Ch.28) and Plumbing (Ch.29) Plan Review Records
SPECIAL DEVICES AND CONDITIONS (Chapters 31, 34)
SPECIAL CONSTRUCTION (Chapter 31)
Membrane structures (3102).
Temporary structures (3103)
Awnings and canopies/Marquees
(3105, 3106)
Signs (3107)
Telecommunication and broadcast
towers (3108)
Swimming pool enclosures (3109)
Automatic vehicular gates (3110)
PEDESTRIAN WALKWAYS AND TUNNELS (3104)
Construction and use (3104.3, 3104.4)
Separation (3104.5, 3104,10)
Public way (3104.6)
Egress (3104.7 - 3104.9)
EXISTING STRUCTURES (Chapter 34)
Building materials (3401.4) Change of occupancy (3408)
Additions, alterations, repairs Accessibility (3411)
(3403 - 3405) Compliance alternatives (3412)
Fire escapes (3406)
-15-
BUILDING EVALUATION SUMMARY (Table 3412.7)
Existing occupancy:
Proposed occupancy:
Year building was constructed:
Number of stories: Height in feet:
Type of construction:
Area per floor:
Percentage of open perimeter increase:
%
Corridor wall rating:
Completely suppressed: Yes
No
Required door closers: Yes No
Compartmentation: Yes
No
Fire -resistance rating of vertical opening enclosures:
Type of HVAC system:
serving number of floors:
Automatic fire detection: Yes
No
type and location:
Fire alarm system: Yes
No
type: -
Smoke control: Yes
No
type:
Adequate exit routes: Yes
No
Dead ends: Yes No
Maximum exit access travel distance:
Elevator controls: YesNo
Means of egress emergency lighting: Yes
No
Mixed occupancies: Yes No
Safety
parameters
Fire Means General
safety (FS) of egress (ME) safety (GS)
3412.6.1 Building height
3412.6.2 Building area
3412.6.3 Compartmentation
3412.6.4 Tenant and dwelling unit separations
3412.6.5 Corridor walls
3412.6.6 Vertical openings
3412.6.7 HVAC systems
3412.6.8 Automatic fire detection
3412.6.9 Fire alarm system
3412.6.10 Smoke control
3412.6.11 Means of egress capacity
3412.6.12 Dead ends
3412.6.13 Max, exit access travel distance
3412.6.14 Elevator control
3412.6.15 Means of egress emergency lighting
3412.6.16 Mixed occupancies
3412.6.17 Automatic sprinklers
- 2 =
3412.6.18 Standpipes
3412.6.19 Incidental accessory occupancy
Building score — total value
No applicable value to be inserted.
BUILDING SAFETY EVALUATION SCORE (Table 3412.9)
Formula Table 3412.7
Table 3412.8 Score Pass Fail
FS—MFS
>_ 0 (FS) —
(MFS) =
ME—MME
>_ 0 (ME) —
(MME) =
GS—MGS
>_ 0 (GS) —
(MGS) =
FS =
Fire Safety
MFS = Mandatory Fire Safety
ME =
Means of Egress
MME = Mandatory Means of Egress
GS =
General Safety
MGS = Mandatory General Safety
APPENDICES A - K
Appendices adopted (101.2.1) Compliance verified
-16-