HomeMy WebLinkAboutProduct Data Sheet; Glass Fiber batts & Blankets•rr i
I
BAY IN STRiFs INC
2929 WA ER DR
PO BOY 9 29.
i,
GREEN Y; W154308 USA
1i
Glass fib r- atts and. blankets with or
B1LNV .RI 1478
Batts. and Blankets
R114.78
The follo �ing products are..eligible to bear the Laboratories' Classification Marking incorporating the designation "F1-IC 25150" instead of the
individiia SturlIke Burning Charactet�istics value' for flame spread acid smoke developed.
nluininut I. oil Faced Blankets
Foil-Setlif ,I- -ail faced Blankets
Vinyl-Sc -Foil Faced.Blankets
1
Vinyl Face Blankets
Vinyl-Scr" ' -Polyester Faced Blankcis
i �.
Polyester S c rim -Kraft Faced Blankets-
, 1,
i
Polyprop hn Scrim -Kraft Faced Blankets
Polyliropylene;Scrini-Foil Faced Blanket's
li
Vinyl-Sq'r ni -Polyester• Faced Blankets
,
Polypropy16 e-Scrim-Pol31estet Faced Blankets
j
Polypron l'.e i.e.Scrim-Kraft-Polyester Faced Blankets
Fait-Fabri ;',Faced Blankets
PolypropyU.e.Fabric Faded Blankets
Coated F
i
I
The appear,.ttli
those prodL
14
UL pemtits t
(flies) musi �e
Certification 1
copyright no i
1
Faced Blankets
6tnri.ebt T) 2010 Underwriters Laboratories inc.0
of a company's name or product in this database does, not in-itsclf assure that produets so identified have been -manufactured under Ut: s Follow -Up Service. only
earinu the UL Mark should be considered tote Listed and covered under UL's Follo>v-Up Service. i\.hvuys look for the Mark an the product.
-eproduction of the nttaterial cyntaimed in the Unline Certification Directory subject. to, file following conditions: I. The Guido iiifottnatioti, Designs and/or Listings
resented in their entirety and init non -misleading inanner, withotit:any manipalation of the data (or drawings). 2. The statement "Reprinted front the Onlinc
(rectory with permission from Underwriters Laboratories Inc." must appear adjacent to -the extracted material. In addition, the reprinted material must include a
in the following format: "Copyright a') 20'10 Under{writers Laboratories InOW
An rndependenn organiz-ation workrnp Iol a safe, world wlllf in1colilr. orac— on and knowledge
t7Polyisocyanurate Foam Sheathing
a Continuous Insulation
Johns Manville
DESCRIPTION
Johns Manville AP" Foil -Faced Foam Sheathing board consists of a uniform closed -cell
polyisocyanurate foam core bonded on each side to a foil facer. One side has a reflective foil
facer and the other side has a white non -reflective foil facer to suit your building needs.
Polyiso provides one of the highest R-values per inch of any rigid insulation (R-6.0 at
1 inch). Furthermore, when properly installed, AP Foil -Faced Foam Sheathing functions
as a water resistive barrier, vapor barrier and air barrier, eliminating the need to install
additional components.
AP Foil -Faced Foam Sheathing is produced with an EPA -compliant hydrocarbon -based blowing
agent that has zero Ozone Depletion Potential (ODP) and virtually no Global Warming Potential
(GWP); it also meets both CFC- and HCFC-free specificationrequirements. Polyiso is one of
North America's most widely used insulation products and has been cited by the EPA for its
responsible impact on the environment.
AP Foil -Faced Foaim Sheathing provides exceptional heat, moisture and air control to protect your
building's exterior wall assembly.
INSTALLATION
AP Foil -Faced Foam Sheathing is lightweight and can be easily cut with a utility knife or saw.
Use maximum board lengths to minimize the number of joints. Vertical joints should be staggered.
Butt joints should be centered over framing. To create a water -resistive barrier or an air barrier,
treat seams and penetrations as instructed in the installation guide and in accordance with
manufacturer's guidelines. Once installed, AP Foil -Faced Foam Sheathing may be left exposed
for up to 60 days. Consult your local building department for code requirements.
COMPLIANCES
• ASTM C1289 Type 1, Class 1
• CAN/ULC S704,Type 1, Class 1
• ICC-ES Evaluation Report ESR-3398
• Canadian Construction Materials Centre 13104-L
• Air Barrier Association of America Evaluated Air Barrier Material,
Assembly & Water Resistive Barrier
• International Building Code
• International Residential Code
• International Energy Conservation Code
• ENERGY STAR
• ASH RAE 90.1
• California State Insulation Quality Standards
PERFORMANCE STANDARDS
• ASTM C1289, Standard Specification for Faced Rigid Cellular PolyisocyanurateThenmal
Insulation Board
• CAN/ULC-S704, Standard for Thermal Insulation, Polyurethane and Polyisocyanurate,
Boards, Faced
• ASTM E84, Test for Surface Burning Characteristics of Building Materials
• CAN/ULC S102; Standard Method of Test for Surface Burning Characteristics of Building
Materials and Assemblies
• NFPA 259, Standard Test Method for Potential Heat of Building Materials
• NFPA 285, Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of
Exterior Non -Load -Bearing Wall Assemblies Containing Combustible Components
• AC 71, Acceptance Criteria for Foam Plastic Sheathing Panels Used as Water -Resistive Barriers
• ASTM E331, Standard Test Method for Water Penetration of Exterior Windows, Skylights,
Doors, and Curtain Walls by Uniform Static Air Pressure Difference
• AATCC Test Method 127, Water Resistance: Hydro Static Pressure Test
• ASTM E1233, Standard Test Method for Structural Performance of Exterior Windows, Doors,
Skylights, and Curtain Walls by Cyclic Air Pressure Differential
• ASTM E2178, Standard Test Method for Air Permeance of Building Materials
• ASTM E2357, Standard Test Method for Determining Air Leakage of Air Barrier Assemblies
AVAILABILITY
AP Foil -Faced Foam Sheathing is available in the sizes shown in Table 1 (see reverse).
'For additional information or special size inquiries, please consult a sales representative
at 800-654-3103.
AP- FOIL -FACED
PERFORMANCE ADVANTAGES
Thermal Insulation: inch for inch, polyiso
has one of the highest energy efficiencies.
R-values for AP Foil -Faced Foam Sheathing
are shown in Table 1, and physical properties
are shown in Table 2'(see reverse). R means
resistance to heat flow. The higher the
R-value, the greater the insulating power.
Water -Resistive Barrier: when properly
installed as part of a Johns Manville Wall
System, AP Foil -Faced Foam Sheathing meets
the ICC-ES AC71 acceptance criteria for foam
plastic sheathing used as a water -resistive
barrier. Please see fhe installation guide for
qualifying assemblies and detailed instructions.
Vapor Barrier: at a minimum thickness
of one inch, AP Foil -Faced Foam Sheathing
has a vapor permeance of 0.05 perms and
qualifies as a Class I vapor retarder.
Air Barrier: when properly installed
as part of a Johns Manville Wall System,
AP Foil -Faced Foam Sheathing meets the
Air Barrier Association of America boardstock
criteria for materials and assemblies. Please
see installation guide for qualifying assemblies
and detailed instructions.
Noncorrosive: does not accelerate
corrosion of pipes, wiring or metal studs.
Lightweight: easy to handle, can be cut with
a utility knife or saw.
ENERGY, QUALITY & ENVIRONMENT
\J ei-s $ abaa
fiYAWATED
Intertelk +*+
Sealandinsulate
ith
POLYISO wENERGY STAR
th
The top performer.
Polyisocyanurate Foam Sheathing
bm"17 Continuous Insulation
Johns Manville
STORAGE
Store AP Foil -Faced Foam Sheathing elevated above the floor or ground
and standing water. If stored outdoors, keep dry by covering completely
with a waterproof tarpaulin.
LIMITATIONS
AP Foil -Faced Foam Sheathing is nonstructural. The walls must be
braced in accordance with the requirements of the applicable code.
WARRANTY
All Johns Manville products are sold subject to Johns Manville's Limited
Warranty and Limitation of Remedy. For a copy of these documents,
call 800-654-3103.
PERFORMANCE DATA
Table 1: Thermal Performance
WARNING
AP Foil -Faced Foam Sheathing is combustible and shall only be used
as specified by the local building code with respect to flame spread
classification and to the use of a suitable thermal barrier when required.
TECHNICAL SERVICES
Johns Manville can provide technical information to assist in
addressing questions regarding AP Foil -Faced Foam Sheathing.
Please call 800-654-3103 for technical assistance.
THICKNESS
If
. R-VALUE'U.S.'
(°F•ftr•h/BTU) `
-THICKNESS °
(mm)"K•m'MI)
RSI-VALUE' ,
' BOARD SIZE `_'
Ihl
R-VALUE WITH REFLECTIVE AIR SPACEz �,
yz'"Air Space
3/0"Air Space : °
. 1"Air Space'
0.50
2.7
13
0.48
4 z 8, 9, or 10
5.2
5.5
5.4
0.625
3.5
16
0.62
4 x 8, 9, or 10
6.0
6.3
6.2
0.75
4.4
19
0.77
4 x 8, 9, or 10
6.8
7.1
7.0
1.00
6.0
25
1.06
4 x 8, 9, or 10
8.5
8.8
8.7
1.50
9.3
38
1.63
4 x 6, 9, or 10
11.7
12.0
12.0
2.00
13
51
2.21
4x8,9,or10
15
15
15
2.50
16
64
2.79
4 x 8, 9, or 10
18
19
19
3.00
19
76
3.36
4 x 8, 9, or 10
22
22
22
3.50
22
89
3.94
4 x 8, 9, or 10
25
25
25
4.00
26
102
4.52
4 x 8, 9, or 10
28
28
28
4.50
28
114
5.09
4 x 8, 9, or 10
30
31
31
'Aged R-value at 75° F in accordance with ASTM C1289.
zOn/y applies when an ideal rellecdve airspace and horizontal heat llowcondidons exist: The shiny foil side of product must face the airspace.
Determined in accordance'vvith FTC 16 CFR Part 460 requirements and published ASHRAE airspace R-values. Refer to the 2009 ASHRAE Handbook of fundamentals, Chapter 26, Table 3, for details
Table 2: Physical Properties
{PROPERTY
UNITS ., _- .
TESTMETHOD-, ,
'" . - RESULT I
Thermal Resistance, I inch
°F•ftz•hr/BTU
ASTM C518*
6.0
Compressive Strength
psi
ASTM D1621
z 16
Flexural Strength
psi-
ASTM C203
> 40
Water Absorption
% by volume
ASTM C209
0.1
Water VaporPermeance
perms
ASTME96
0.05
Surface Burning Characteristics**
Flame Spread'
index
ASTM E84
_< 25
Smoke Developed'
index
ASTM E84
_< 450
Service Temperature
°F
-100 to 250
Aged R-value at 75°Fin accordance with ASTM C1289.
"Numerical ratings are not intended to reflect hazards present in actual fire conditions.
'Foam core tested at 4 inches.
Johns Manville
Visit our website at www.JM.com or call 800-654-3103 1 Building Insulation Division P.O. Box 5108 ( Denver, CO 80217-5108
Data as shown in this literature is intended to be used as a general guideline only. The physical and chemical properties of.AP Foil -Faced
Polyisocyanu rate Foam Sheathing listed herein represent typical, average values obtained in accordance with accepted test methods and are subject
to normal manufacturing variations. They are supplied as a technical service and are subject to change without notice. Any references to numerical
flame spread or smoke developed ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions.
Check with the sales office nearest you for current information. All Johns Manville products are sold subject to Johns Manville's Limited Warranty and
Limitation of Remedy. For a copy of the Johns Manville Limited Warranty and Limitation of Remedy or for information on other Johns Manville thermal
and acoustical insulation and systems, visit the website or call the 800 number above. 71717th Street Denver CO, 80202
BID-0151 6/14
© 2014 Johns Manville. All Rights Reserved.
Formaldehyde -Freer' Fiber Glass Insulation UNFACED
Ilm"17 Enhanced with Bio-Based Binder KRAFT FACED
FOIL FACED
Johns Manville
PRODUCT DATA,
COMPANY
Johns Manville is committed to creating more comfortable, healthier and energy
efficient indoor environments. We revolutionized the building insulation industry by
pioneering the development of Formaldehyde -free'" fiber glass building insulation
over a. decade ago. We continue to build on our legacy of innovation with a new
Formaldehyde -freer" fiber glass insulation solution that utilizes an innovative bio-based
binder, made mostly with rapidly renewable plant -based materials, that continues to
offer excellent thermal and acoustical performance as well as improved handling,
easier cutting and less dust than our previous. product. At JM, we believe that in
every detail, materials matter.
DESCRIPTION
JM Formaldehyde -free"' thermal and acoustical insulation is made of long, resilient
glass fibers bonded with our bio-based binder. A wide range of thermal resistance
R-values is available to provide thermal control for both vertical and horizontal
applications. JM insulation is available unfaced or faced with a variety of facings,
including kraft or foil vapor retarder.
USE
JM Formaldehyde -free'' thermal and acoustical insulation can be used in a
wide variety of wood frame, engineered wood and steel frame construction
applications, including:
New Construction: residential homes and commercial buildings interior and
exterior walls, floors and ceilings for thermal and sound control, as well as basement
wall insulation.
Retrofit: adding insulation to attics, crawl spaces and above suspended ceilings.
INSTALLATION
JM insulation cuts easily with an ordinary utility knife, and unfaced or tabless
versions install easily by simply pressing in place between studs or joists in standard
framing. Standard facings have stapling tabs for attachment to framing if additional
securement is required.
PACKAGING
JM insulation is compression -.packaged for savings in storage and freight costs
DESIGN CONSIDERATIONS
Kraft and standard foil facings on this product will burn and must not be left exposed.
It must be covered with gypsum board or another approved interior finish. Where an
exposed application is required, use FSK-25 flame -resistant faced insulation.
In colder climate areas, vapor retarders (whether attached to the insulation or applied
separately) are often placed toward the heated or conditioned side of the wall. This is
done to reduce water vapor penetration into the wall from the building interior.
Check your local building codes for vapor retarder requirements.
Refer to JM guide specifications for further design considerations and required
installation instructions.
LIMITATIONS OF USE
Check applicable building codes.
PERFORMANCE ADVANTAGES
Formaldehyde -free: will not off -gas
formaldehyde.in the indoor environment.
Thermal Efficiency: provides effective
resistance to heat transfer with R-values
up to R-38 (RSI-6.7).
Sound Control: reduces transmission of
sound through exterior and interior walls
and floor or ceiling assemblies.
Fire. Resistant and Noncombustible:
see Specification Compliance.
Durable Inorganic Glass: will not rot,
mildew or deteriorate and is noncorrosive
to pipes, wiring and metal studs.
Superior Performance: bonded glass
fibers are dimensionally stable and will
not slump within the wall cavity, settle or
break down during normal applications.
ENERGY AND ENVIRONMENT
U`.
- -. GRE6NGUAI
A w;.
ENERGIISTAR „�,•,
PARTNER, yrnn:
Formaldehyde-Freelm Fiber Glass
Enhanced with
APPLICABLE STANDARDS & BUILDING CODE CLASSIFICATION*
ASTM C665, Type I; ASTM El36 ASTM C665, Type II Class C, Category 1 ASTM C665, Type III, Class B, Category 1
IBC, ALL TYPES IBC TYPES ll, IV, V IBC TYPES III, IV, V
'JA4Insulation complies with 18C (International Building Code), model code requirements for building construction types listed above.
STANDARD SIZES'
R-VALUE
ihr "ft�e°FlBtul -., .
RSI VALUE
.-•
' +( , "CIUUattsl . m °
THICKNESS**
WIDTH' :' a
:' ►n (tore'), '„
- METAL FRAMING rn (inro)�
t. WOOD FRAMING to im`ml-:. . .
a
2Y4 (70)
16. (406)
24 (610)
—
11
1.9
3Y2 (89) 3YB (92)
16 (406)
24 (610)
15 (381)
19.(483)
23 (584)
13
2.3
3Y2 (89) No (92)
16 (406)
24 (610)
15 (381)
23 (584)
15
2.6
3Y2 (89)
—
15 (381)
19
3.3
6Y2(166)
16(406)
24(61.0)
15(381)
19(483)
23(584)
21
3.7
5Y2(140)
16(406)
15(381)
23(584)
22
3.9
7Y2 (191)
—
15 (381)
25
4.4
8Y2 (216)
16 (406)
24 (610)
15.(Al)
19 (483)
23 (584)
30
5.3
10Y4 (260)
16 (406)
24 (610)
16 (406)
19 (483)
24 (610)
30c
5.3
8Y4 (210)
15Ys (394)
23%s(600)
38
6.7
13(330)
16(406)
24(610)
16(406)
24(610)
38c
1 6.7
1 10% 260)
1 15Y2 394
235/a 600
'Consult your local JM sales representative or product availability chart for available sizes and R-values (RSI-values) including wide -roll products.
—Thickness may varyby producing location.
Special widths and lengths may be available. Check with your localJM sales representative. Standard product lengths include 48 , 93" and 96' (1219 rum, 2362 and 2438 mm) batts.
AFor sound control applications in interior walls.
cCathedral ceiling application.
PHYSICAL PROPERTIES"
PRODUCTION
FLAME SPREAD, ;
SMOKE DEVELOPEDt
VAPOR RETARDER (PERMS►,
w WATER VAPOR SORPTION 1;
=DIMENSIONAL STABILITY-- J
Unfaced
<25
<50
N/A
<5%
Less than 0.1%
Foil Faced
<75
<150
0.05.
N/A .
Less than 0,1%
Kraft Faced
N/R
N/R
1
N/A
Less than 0.1%
"'Products are tested in accordance: R-value ASTM C518 I Surface'Sufning Characteristics ASTM E84 I Fami Rating ASTM E96 I Water Vapor Sorption ASTM Cl 104
Kraft and standard foil facing will burn. Do not leave exposed. Facing must be installed insubstantial contact with an approved ceiling, floor or wall material Keep open Same and other heat sources
away from facing. Do not place insulation within Y of light fixtures or similar electrical devices unless device is labeled for contact with insulation. Use only unfaced insulation between wood framing
and masonry chimneys. Do not use insulation in spaces around metal chimneys, (replaces, or flues. JM Unlaced insulation is considered non-combustible by model building codes. Flame Spread 25
products are flame spread rated and can be left exposed.where codes allow. See package for warnings, fire hazard and installation instructions, or call 800-654-3 103.
Due to potential skin irritation, unlaced insulation should not be used for exposed applications where it will be subject to human contact.
17"
Johns Manville
Visit our website.at www.JM.com or call 800-654-3103 1 Building Insulation Division P.O. Box 5108 1-Denver, CO 80217-5108
Technical specifications as shown in this literature are intended to be used as general guidelines only, The physical and chemical properties of thermal
and acoustical fiber glass insulation listed herein represent typical, average values obtained in accordance with accepted test methods and are subject
to normal manufacturing variations. They are supplied as a technical service and are subject to change without notice. Any references to numerical flame
spread or smoke developed ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions. Check with
the sales office nearest you for current information. All Johns Manville products are sold subject to Johns Manville's Limited Warranty and Limitation of
Remedy. For a copy of the Johns Manville Limited Warranty and Limitation of Remedy or for information on other Johns Manville thermal and acoustical
insulation and systems, visit the website or call the 800 number above. 717 17th Street Denver CO, 80202
BID-0144 6/14
© 2014 Johns Manville. All Rights Reserved.