Loading...
HomeMy WebLinkAboutResponses to Comments; Building & Structuralar it tureLA i e/MI /' 111 June 30, 2014 St.Lucie County Planning & Development Services 2300 Virginia Avenue Fort Pierce, FL 34982 RE: Permit Application Number: 1405-0345 Savannah Club HOA, Inc. 3492 Crabapple Drive Project Number: 13-0629 Dear Sirs: Please accept these responses to your conditions dated 6/25/2014: BUILDING & STRUCTURAL: 1. Comment: UL P521 2 HR Ceiling assembly requires 2 layers of 5/8 wallboard. Please show this requirement in all details and references. Response: Detail B3 on. Sheet A1.1 has been revised to show (2) layers of 518"type "X" grywall. Please refer to A1.1 2. Comment: Please replace 2 HR wall requirement detail 7, Sheet A1.0, with required detail U419,Ref on Sheet A1.1 Detail 7 top track attachment is required to be concrete deck, and cannot.be achieved.with this roof/ceiling assembly. Response: The detail 7 has been changed to the detail for UL #U419 2=hour fire rated wall. Please refer to sheet Al.0 3. Comment: Please include structural inspection plan for special inspector requirement for a threshold building complying with the requirements of FBC110.3.7 Response: Will comply please see revised Structural drawing Sheet S.1 4. Comment: Please note all kitchen hoods must be permitted separately. Response: A note has been added to sheet A6.1 that "all kitchen hoods shall be under separate permit". 5. Comment: This project does not appear to meet the requirements of Type II A Construction, please reclassify on plans to reflect correct construction type. Response: The construction type has been revised to type. II-B, please refer to A0.1 6. Comment: Please submit soil report, with conclusions and recommendations of Geotechnical Engineer. Response: Shall be supplied by General Contractor 7. Comment:.Please note all flame spread and smoke developed index for all finishes used on wall, ceiling and floor finishes, used. Response: The requested notations have. been provided.refer to finish schedule Sheet A2.4 8. Comment: Please include finish classifications for all wall,, ceiling and.floor finishes used. Response: The requested notations have been provided refer to finish schedule Sheet A2.4 9. Comment: Please include all flame spread and smoke developed index for all insulation used. Response:. The flame,spread and smoke developed index has been provided. Please refer to A1.1 & A1.2 for the information attached: 1235 SE Indian Street, Suite 1.03 Stuart, FL 34997 0: (772) 287-7330 F: (772) 287-8992 www.crossroadsarchitecture.biz Lic# AA26000832 I Ca crossroads ar Please contact our office should you have any further questions. t. A. 1235 SE Indian Street, Suite 103 Stuart, FL 34997 O: (772) 287-7330 f: (772) 287-8992 www.crossroadsarchitecture.biz Lic# AA26000832