Loading...
HomeMy WebLinkAboutSubsurface Exploration & Geotechnical Engineering EvaluationIII ' Florida's Leading Engineering Source Environmental • Geotechnical-- Construction Materials Testing • Threshold and Special Inspections - Plan Review 3 Code Compliance Nq �,`'�0RNATXO Qy Commercial Contracting Division, Inc. Attention: Ms. April Laraway 709 SE 5 h Street Stuart, Florida 34994 Site: Proposed Community Center Building at Savanna Club 3492 Crabapple Drive St. Lucie County, Florida GFA Project # 14-0097.01 Dear Ms. Laraway: July 2, 2014 GFA International, Inc. (GFA) has completed the subsurface exploration and geotechnical engineering evaluation- for the above -referenced project in accordance with- the geotechnical and engineering service agreement for this project. The scope of services was completed in accordance with our Geotechnical Engineering Proposal (14-0097.01) dated July 1, 2014, planned in conjunction with and authorized by you. EXECUTIVE SUMMARY The purpose of our subsurface exploration was to classify the nature of the subsurface soils and general geomorphic conditions and evaluate their impact upon the proposed construction. This report contains the results of our subsurface exploration at the site and our engineering interpretations of these, with respect to the project characteristics described to us including providing recommendations for site preparation and the design of the foundation system. Based on a site plan prepared by McCarty & Associates latest revision dated 07-24-13 (reproduced in Appendix B - Test Location Plan) and conversations with the client, the project consists of demolishing and removing portions of an existing building and other structures, and then constructing a one-story clubhouse building with walls about 18 feet high. The new buiding will be connected to portions of the remaining structures. We have not received any information regarding structural loads. For the foundation recommendations presented in this report we assumed the maximum column load will be 70 kips and the maximum wall loading will be 4 kips per linear foot. GFA estimates that 0 to 1 foot of fill will be required to bring the foundation pad to design grade. The recommendations provided herein are based upon the above considerations. If the project description has been revised, please inform GFA International so that we may review our recommendations with respect to any modifications. A total of five (5) Cone Penetrometer Test (CPT) soundings to depths of approximately seventeen (17) and twenty (20) feet, and five (5) Auger Borings (AB) to approximately five (5) feet, below ground surface (BGS) were completed for this study. 521 NW Enterprise Drive - Port St. Lucie, Florida 34986 - I OFFICES 924.3575 - (772) 924.3580 r FLORIDA Proposed Community Center Building at Savanna Club 3492 Crabapple Drive, St. Lucie County, Florida GFA Project No. 14-0097.01 Geotechnica/ Report July 2, 2014 Page 2 of 9 The subsurface soil conditions encountered at this site generally consist of sand (SP) to slightly silty sand (SP-SM,SM) to the auger boring termination depths of 5 feet. The CPT soundings generally indicated BGS the soils were loose to a depth of 1 foot, and then medium dense to the sounding termination depths of 17 and 20 feet. Very dark brown organically stained sand with some slit (SM) was encountered with the top as shallow as 4 feet and the bottom as deep as 5 feet or more below ground surface was encountered. The CPT values were indicative of sandy soils below the auger boring termination depths. Please refer to Appendix D - Record of Test Borings for a detailed account of each boring and sounding. The subsurface soil conditions at the project site are generally favorable for the support of the proposed structures on shallow foundations. An allowable bearing capacity of 2,500 psf may be used for foundation design. The subgrade soils should be improved wii constructing the foundation pads. The top 2 f a minimum of 95% density prior to placing fi' backfill) should be placed in 12-inch lifts and After excavation for footings, the subgrade to be compacted to achieve a minimum 95% den compaction from the stripped grade prior to :t below stripped grade should be compacted to to achieve final grade. Fill (including stemwall ompacted to achieve a minimum 95% density. depth of 2 feet below bottom of footings should We appreciate the opportunity to be of servide to you on this project and look forward to a continued association. Please do not hesitate to contact us if you have any questions or comments, or if we may further assist you as your plans proceed. � ,,&111M11�1111, Respec *I; zm t q GFA I i ,inC. •. '�� Flori06'rewc �Authdl�j a n Number 493t3 ZaW% oZ l&r� �.E �OQ ��-r Florida F�dgt Q11 ,%. 075 Mf Copies: 2, Addressee Project Manager Proposed Community Center Building at Savanna Club Geotechnical Report 3492 Crabapple Drive, St. Lucie County, Florida July 2, 2014 GFA Project No. 14-0097.Of Page 3 of 9 TABLE OF CONTENTS 1.0 INTRODUCTION.................................................................................................................4 1.1 Scope of Services ...................................... .......................................................................4 1.2 Project Description..........................................................................................................4 2.0 OBSERVATIONS.................................................................................................................4 2.1 Site Inspection ;- 2.2 Field Exploration...........................................................................................................5 2.3 Laboratory Analysis................................M......................................................................5 2.4 Geomorphic Conditions ........................... ........................................................................ 5 2.5 Hydrogeological Conditions....................:......................................................................6 3.0 ENGINEERING EVALUATION AND RECOMMENDATIONS..............................................6 3.1 General...........................................................................................................................6 3.2 Site Preparation...............................................................................................................6 3.3 Design of Footings `° ..............8 ..................................:.................................................................... 3.4 Ground Floor Slabs .....................................................................8 F 4.0 REPORT LIMITATIONS.......................................................................................................8 5.0 BASIS FOR RECOMMENDATIONS..................................................................................9 Appendix A - Vicinity Map Appendix B - Test Location Plan Appendix C - Notes Related to Borings Appendix D - Record of Test Borings t Appendix E - Discussion of Soil Groups GF� Proposed Community Center Building at Savanna Club Geotechnical Report 3492 Crabapple Drive, St. Lucie County, Florida July 2, 2014 GFA Project No. 14-0097.01 Page 4 of 9 1.0 INTRODUCTION 1.1 Scope of Services The objective of our geotechnical services was to collect subsurface data for the subject project, summarize the test results, and discuss any apparent site conditions that may have geotechnical significance for building construction. The following scope of services is provided within this report: 1. Prepare records of the soil boring logs depicting the subsurface soil conditions encountered during our field exploration. 2. Conduct a review of each soil sample obtained during our field exploration for classification and additional testing if necessary. 3. Analyze the existing soil conditions found during our exploration with respect to foundation support for the proposed structure. 4: Provide recommendations with respect to foundation support of the structure, including allowable soil -bearing capacity, bearing elevations, and foundation design parameters. 5. Provide criteria and site preparation procedures to prepare the site for the proposed construction. 1.2 Project Description Based on a site plan prepared by McCarty & Associates latest revision dated 07-24-13 (reproduced in Appendix B - Test Location Plan) and conversations with the client, the project consists of demolishing and removing portions of an existing building and other structures, and then constructing a one-story clubhouse building with walls about 18 feet high. The new buiding will be connected to portions of the remaining structures. We have not received any information regarding structural loads. For the foundation recommendations presented in this report we assumed the maximum column load will be 70 kips and the maximum wall loading will be 4 kips per linear foot. GFA estimates that 0 to 1 foot of fill will be required to bring the foundation pad to design grade.. The recommendations provided herein are based upon the above considerations. If the project description has been revised, please inform GFA International so that we may review our recommendations with respect to any modifications. 2.0 OBSERVATIONS 2.1 Site Inspection The project site was generally flat. The location of the proposed building was occupied by an existing building and other structures. The grade at the site was estimated to be 2 feet above the adjacent road at the time of drilling. GF� Proposed Community Center Building at Savanna Club Geotechnical Report 3492 Crabapple Drive, St. Lucie County, Florida July 2, 2014 GFA Project No. 14-0097.01 Page 5 of 9 2.2 Field Exploration , A total of five (5) Cone Penetrometer Test (CPT) soundings to depths of approximately seventeen (17) and twenty (20) feet, and five (5) Auger Borings (AB) to approximately five (5) feet, below ground surface (BGS) were completed for this study. The locations of the soundings and borings performed are illustrated in Appendix B: "Test Location Plan". The Cone Penetrometer Test (CPT) methods were used as the investigative tools. CPT tests were performed in substantial accordance with ASTM Procedure D-3441, "Deep Quasi -Static, Cone and Friction Cone Penetration Tests of Soils" and the auger borings in substantial accordance with ASTM Procedure D-1452, "Practice for Soil Investigation and Sampling by Auger Borings". The soil samples recovered from the soil borings were visually classified and their stratification is illustrated in Appendix D: 'Record of Test Borings". It should be noted that soil conditions might vary between the strata interfaces, whichloare shown. The soil boring and sounding data reflect information from a specific test location*only. Site specific survey staking for the test locations was not provided for our field exploration. The indicated depth and location of each test was approximated based upon existing grade and estimated distances and relationships to obvious landmarks. The boring and sounding depths were confined to the zone of soil likely to be stressed by the proposed construction and khowledge of vicinity soils. 2.3 Laboratory Analysis Soil samples recovered from our field exploration were returned to our laboratory where they were visually examined in general accordance with ASTM D-2488. Samples were evaluated to obtain an accurate understanding of the soil properties and site geomorphic conditions. After a thorough visual examination of the recovered ;-site soils, no laboratory testing was deemed necessary. Bag samples of the soil encountered during our field exploration will be held in our laboratory for your inspection for 30 days and then discarded unless we are notified otherwise in writing. y.. The recovered samples were not examined either visually or analytically, for chemical composition or environmental hazards. GFA would be pleased to perform these services for an additional fee, if required. 2.4 Geomorphic Conditions The geology of the location of the proposed building as mapped on the USDA Soil Survey website consists of Waveland and Immokalee-fine sands (50). These are sandy soils and organic soils are not indicated. It should be rioted that the Soil Survey generally extends to a maximum depth of 80 inches (approximately 6%T6et) below ground surface and is not indicative of deeper soil conditions. Boring logs derived from our field exploration are presented in Appendix D: 'Record of Test Borings". The boring logs depict the observed soils in graphic detail. The CPT soundings indicate the penetration resistance values logged during the test. The classifications and descriptions shown on the logs are generally based upon visual characterizations of the recovered soil samples. All soil samples reviewbd'have been depicted and classified in general accordance with the Unified Soil Classification System, modified as necessary to describe GF Proposed Community Center Building at Savanna Club Geotechnical Report 3492 Crabapple Drive, St. Lucie County, Florida July 2, 2014 GFA Project No. 14-0097.01 Page 6 of 9 typical Florida conditions. See Appendix E: "Discussion of Soil Groups", for a detailed description of various soil groups. The subsurface soil conditions encountered at this site generally consist of sand (SP) to slightly silty sand (SP-SM,SM) to the auger boring termination depths of 5 feet. The CPT soundings generally indicated BGS the soils were loose to a depth of 1 foot, and then medium dense to the sounding termination depths of 17 and 20 feet. Very dark brown organically stained sand with some silt (SM) was encountered with the top as shallow as 4 feet and the bottom as deep as 5 feet or more below ground surface was encountered. The CPT values were indicative of sandy soils below the auger boring termination depths. Please refer to Appendix D - Record of Test Borings for a detailed account of each boring and sounding. 2.5 Hydrogeological Conditions On the dates of our field exploration, the groundwater table was encountered at depths ranging from approximately 2% to 5 feet below the existing ground surface. The groundwater table will fluctuate seasonally depending upon local rainfall and other site specific and/or local influences. Brief ponding of stormwater may occur across the site after heavy rains. No additional investigation was included in our scope of work in relation to the wet seasonal high groundwater table or any existing well fields in the vicinity. Well fields may influence water table levels and cause significant fluctuations. If a more comprehensive water table analysis is necessary, please contact our office for additional guidance. 3.0 ENGINEERING EVALUATION AND RECOMMENDATIONS 3.1 General ar A foundation system for any structure must be designed to resist bearing capacity failures, have settlements that are tolerable, and resist the environmental forces that the foundation may be subjected to over the life of the structure. The s4QQil bearing capacity is the soil's ability to support loads without plunging into the soil profile. Baring capacity failures are analogous to shear failures in structural design and are usually sudden and catastrophic. The amount of settlement that a structure may tolerate is dependent on several factors including: uniformity of settlement, time rate of settlement, structural dimensions and properties of the materials. Generally, total or uniform settlement does not damage a structure but may affect drainage and utility connections. These -,can generally tolerate movements of several inches for building construction. In contrast, differential settlement affects a structure's frame and is limited by the structural flexibility. The subsurface soil conditions at the project site are generally favorable for the support of the proposed structure on shallow foundations. An allowable bearing capacity of 2,500 psf may be used for foundation design. Expected settlement of the structure is 1 inch or less total and less than'h inch differential. Please be aware that differential settlement between existing and new structures is to be expected. A construction joint between the existing and new structures should be considered if the addition will be attached to existing structure. GF Proposed Community Center Building at Savanna Club Geotechnical Report 3492 Crabapple Drive, St. Lucie County, Florida July 2, 2014 GFA Project No. 14-0097.01 Page 7 of 9 3.2 Site Preparation GFA recommends the following compaction requirements for this project: ➢ Proof Roll......................................................................95% of a Modified Proctor ➢ Building Pad Fill............................................................95% of a Modified Proctor ➢ Footings........................................................................95% of a Modified Proctor The compaction percentages presented above are based upon the maximum dry density as determined by a modified proctor' test (ASTM D-1557). All density tests should be performed to a depth of 2 feet below stripped surface and below bottom of footings. All density tests should be performed using the n rcrclear method (ASTM D-2922), the sand cone method (ASTM D-1556), or Hand Cone Penetrometer (HCP) tests. Our recommendations for preparation of the site for use of shallow foundation systems are presented below. This approach to improving and maintaining the site soils has been found to be successful on projects with similar soil condiilions. 1. Initial site preparation should consist of performing stripping (removing surface vegetation, near surface roots, and other deleterious matter) and clearing operations. This should be done within, and to a distance of five (5) fee beyond, the perimeter of the proposed building footprint (including exterior isolated column}. Foundations and any below grade remains of any structures that are within the footprint of the new construction should be removed, and utility lines should be removed or properly a andoned so as to not affect structures. 2. Following site stripping and prior the placement of any fill, areas of surficial sand (not exposed limestone) should be compacted ("'roof rolled") and tested. We recommend using a steel drum vibratory roller with sufficient static weight and vibratory impact energy to achieve the required compaction. Density+tests should be performed on the proof rolled surface at a frequency of not less than one t'st per 2,500 square feet, or a minimum of three (3) tests, whichever is greater. Areas of exposed intact limestone shall be visually confirmed by the project geotechnical engineer prior tofill placement, in lieu of proof rolling. 3. Fill material may then be placed in the bull ng pad as required. The fill material should be inorganic (classified as SP, SW, GP, GW, S , -SM, SW-SM, GW-GP, GP -GM) containing not more than 5 percent (by weight) organic rri "terials. Fill materials with silt/clay-size soil fines in excess of 12% should not be used. Fill should be placed in lifts with a maximum lift thickness not exceeding 12-inches. Eacl1'lift should be compacted and tested prior to the placement of the next lift. Density tests shobd be performed within the fill at a frequency of not less than one test per 2,500 square feat per lift in the building areas, or a minimum of three (3) tests per lift, whichever is greater. , 4. For any footings bearing on a limestone formation, the bottom of all footing excavation shall be examined by the engineer / geologist orris representative to determine the condition of the limestone. The limestone shall be probed for voids and loose pockets of sand. Such areas shall be cleaned to depth of 3 times the greatest horizontal dimension and backfilled with lean concrete. GF� Proposed Community Center Building at Savanna Club Geotechnical Report 3492 Crabapple Drive, St. Lucie County, Florida July 2, 2014 GFA Project No. 14-0097.01 Page 8 of 9 5. For footings placed on structural fill or compacted native granular soils, the bottom of all footings shall be tested for compaction and examined by the engineer / geologist or his representative to determine if the soil is free of organic and/or deleterious material. Density tests should be performed at a frequency of not less than one (1) density test per each isolated column footing and one (1) test per each seventy five (75) lineal feet of wall footings. If compaction cannot be attained due to persistent wetness or the water table near the bottom of the footing excavation, or due to silty/clayey soil 'pumping' during compaction, GFA recommends undercutting below bottom of footing and replacement with No. 57 stone, or rock/sand fill for subgrade that cannot be compacted per recommendations (upper 2 feet). The rock/sand fill should be compacted and tamped into the excavation and inspected and verified by a representative from GFA, and tested with hand cone penetrometers, probe rods, or density tests. 6. The contractor should take into account the*tinal contours(and grades as established by the plan when executing his backfilling and compaction operations. Using vibratory compaction equipment at this site may disturb adjacent structures. We recommend that you monitor nearby structures beifore and during proof -compaction operations. A representative of GFA International can monitor the vibration disturbance of adjacent structures. A proposal for vibration monitonng'during compaction operations can be supplied upon request. 3.3 Design of Footings Footings may be designed using an allowably soil bearing pressure of 2,500 psf. Shallow foundations should be embedded a minimum 18 inches below final grade. This embedment shall be measured from the lowest adjacent g Vie. Isolated column footings should be at least 24 inches in width and continuous strip footinr�ggs should have a width of at least 18 inches regardless of contact pressure. Footings near trie pool should be extended so that the bottoms of the footings are below the nearby bottom of the pool. Once site preparation has been performed in accordance with the recommendations described in this report, the soil should readily supports the proposed structure resting on a shallow foundation system. Settlements have been projected to be less than 1-inch total and %z-inch differential. All footings and columns should ba structurally separated from the floor slab, as they will be loaded differently and at different' times, unless a monolithic mat foundation is designed. 3.4 Ground Floor Slabs The ground floor slabs may be supported directly on the existing grade or on granular fill following the foundation site preparation and fiH placement procedures outlined in this report. For purposes of design, a coefficient of subgrade modulus 150 pounds per cubic inch may be used. The ground floor slab should be structurally separated from all walls and columns to allow for differential vertical movement. Excessive moisture vapor transmission through floor slabs -on -grade can result in damage to floor coverings as well as cause other deleterious. affects. An appropriate moisture vapor GF� Proposed Community Center Building at Savanna Club Geotechnccal Report 3492 Crabapple Drive, St. Lucie County, Florida July 2, 2014 GFA Project No. 14-0097.01 Page 9 of 9 retarder should be placed beneath the floor slab to reduce moisture vapor from entering the building through the slab. The retarder should be installed in general accordance with applicable ASTM procedures including sealing around pipe penetrations and at the edges of foundations. 4.0 REPORT LIMITATIONS This consulting report has been prepared for the exclusive use of the current project owners and other members of the design team for the Proposed Community Center Building at Savanna Club located at 3492 Crabapple Drive, St. Lucie County, Florida. This report has been prepared in accordance with generally accepted local geotechnical engineering practices; no other warranty is expressed or implied. The evaluation submitted in this report, is based in part upon the data collected during a field exploration, however, the nature and extent of variations throughout the subsurface profile may not become evident until the time of construction. If variations then appear evident, it may be necessary to reevaluate information and professional opinions as provided in this report. In the event changes are made in the nature, design, or locations of the proposed structure, the evaluation and opinions contained in this report shall not be considered valid, unless the changes are reviewed and conclusions modified or verified in writing by GFA International. 5.0 BASIS FOR RECOMMENDATIONS The analysis and recommendations submitted in this report are based on the data obtained from the tests performed at the locations indicated on the attached figure in Appendix B. This report does not reflect any variations, which may occur between borings. While the borings are representative of the subsurface conditions at their respective locations and for their vertical reaches, local variations characteristic of the subsurface soils of the region are anticipated and may be encountered. The delineation between soil types shown on the soil logs is approximate and the description represents our interpretation of the subsurface conditions at the designated boring locations on the particular date drilled. Any third party reliance of our geotechnical report or parts thereof is strictly prohibited without the expressed written consent of GFA International. The applicable SPT methodology (ASTM D-1586), CPT methodology (ASTM D-3441), and Auger Boring methodology (ASTM D-1452) used in performing our borings and sounding, and for determining penetration and cone resistance is specific to the sampling tools utilized and does not reflect the ease or difficulty to advance other tools or materials. Gfi� Appendix A - Vicinity Map GF I f—e �.�F-' a a p S ow; gle Dr ell 288 R I 94p I F, I 'INP Isft t 1269 ft 9 Irig-Ei Dcjte at, Vo L Appendix B - Test Location Plan Gf 0 Test Location Plan: Proposed Community Center Building at Savanna Club, 3492 Crabapple Dr., St. Lucie Count FL P Y 9 PP Y� SITE, McGmr' &A,&x-mm ca+a.,ra..•n•..,wu , Dew p o.xAreaUrz ��l� f i..__—..---T---J caY»oaama.ra.»evAvrwn »r,.. .�». CPT-5 - - CPT-4_._ d II�twS,�aa»NYO0tY .•�,. � I� ee�K\•-K: www,aa.wwa. nmr.,»ww.s, ��•". •ry ~ •-•• fr - ` m r. , M IL :.?.nrn•,s,-».w »onn•nu.,e.arri ...:...-•a..,... .: w»aoswua rwn, v;.nes,w.... a b-. .E ea CPT-3-�=,,.x.�-----•-----�, . � a »U.mson,wwaenro.e:__�•.,..........,.___.�.....- .r r _ I -", U -.�. wwrnarnnne•,a \ ': 1 - z' =-_'� _-�-- r'I LS 44 Legeroes�pBon a ,` \ `...• � �.�,U. 4E '�w.M..�n�aewwMY.w'.nr.w.•v`anm;n .. \ \.,`• , ; �� ^— _ .n•... .- wrw �..•,-.. '� ti\ : ... �; , CPT-2 m o �+t"iswsv,onnontFnawe� •'\ J(r I ' i icr �w.u�rw,ww•w.eaunaw, uwa � •,\•``y • \ t / -- F .... �.rn•„'ao Rr�rc mwlnn.m.wa.w.teas•ro ` \\ ii e1V�°'-4 ..., r. cvawcw,..: �r,�n"'.a."'�.v"n nm""n.�.w".."' \• a \�. ' Z 0M�Rw�M 14�-�'wldf'•'iW»a M+.C:r'M•Y. '\ `l '♦ •\• ` •� Sw tw.. ,� � !•f-2•LD,Y..,•sw!� ` 'w�e'»ciiLLw�'wnK.'L•Mµ G•,V�e.'•O"�Ou[ •�p•� • , \ X__.r. w"�"aa:i.�.wei°wra'�o..waue»w.ac+ rww•ua*no \ \ .:ram •. s •rs...,wcww.. n'.waono. wcow..ra�wwua ��. CPT-1 waiwaa,e+uawn!wbamn iiiewaroYv ''\ \ •4 \ , •'-r-'-+ ,oe+.aw..crwµmarr.o,o wrrna.nrwrr. www,a cnnkro..w». �, � • _ ••\ ` \ . \ •``• ..:.,. ' \1. I �� Dmwn a st. Drak,age Ndee _ ♦ """-••� •} �` \ 1. . e I ...... •. Checked ey " et. McCaey ..»•a•w.nx-w.ewee..wwe•.n.-Yu., \ I r=str.a- ...awcwanwnaanno.awuo.arv.awewwr»w ♦ `. � �. �.` ' \,•. �♦. .. .. SWe—_........ _..__._ +e+o•�• • \ fi, /• ♦ ' 1 13 kM Date 11•t&14 •wn•en»s+.:-»eww.ro..a,.ewrwmrwnawn +• '♦ � L 1••+•-.-.• � OS311S ranvvrowrwnm+'r»..'.'O1•<'+wr�.�r.,aeao•enra,ua .\ •,�flj ♦ '� �\ DO pM:roam �. �.i.., n,.:ow •,� j\S `y�` ..... �`�` `R. /�� _..Eremmmenn o7-?a.i3 `� �` '♦ `\tires. �w�:..:.� '.'u \ ` ♦c ♦ „ .'��� �, : " _ . NORTH w�a r . �..»...nm �.� w�_ \,. ,• b Sheet 2 of 2 •-Approximate Cone Penetrometer Test (CPT) Sounding & Auger Boring (AB) Locations Appendix C - Notes Related to Borings Gf� NOTES RELATED TO RECORDS OF TEST BORING AND GENERALIZED SUBSURFACE PROFILE 1. Groundwater level was encountered and recorded (if shown) following the completion of the soil test boring on the date indicated. Fluctuations in groundwater levels are common; consult report text for a discussion. 2. The boring location was identified in the field by offsetting from existing reference marks and using a cloth tape and survey wheel. 3. The borehole was backfilled to site grade following boring completion, and patched with asphalt cold patch mix when pavement was encountered. 4. The Record of Test Boring represents our interpretation of field conditions based on engineering examination of the soil samples. 5. The Record of Test Boring is subject to the limitations, conclusions and recommendations presented in the Report text. 6. "Field Test Data" shown on the Record of Test Boring indicated as 11/6 refers to the Standard Penetration Test (SPT) and means 11 hammer blows drove the sampler 6 inches. SPT uses a 140-pound hammer falling 30 inches. 7. The N-value from the SPT is the sum of the hammer blows required to drive the sampler the second and third 6- inch increments. 8. The soil/rock strata interfaces shown on the Records of Test Boring are approximate and may vary from those shown. The soil/rock conditions shown on the Records of Test Boring refer to conditions at the specific location tested; soil/rock conditions may vary between test locations. 9. Relative density for sandstgravels and consistency for silts/clays are described as follows: SPT CPT SANDS/GRAVELS SPT CPT SILTS/CLAYS BLOWS/FOOT KG/CM- RELATIVE DENSITY BLOWS/FOOT KG/CM- CONSISTENCY 0-4 0-16 Very loose 0-1 0-3 Vety soft 5-10 17-40 Loose 2-4 4-6 Soft 11-30 41-120 Medium Dense 5-8 7-12 Finn 31-50 121-200 Dense 9-15 13-25 Stiff 50+ over 200 Very Dense 16-30 25-50 Very stiff >30 >50 Hard 10. Grain size descriptions areas follows: NAME SIZE LIMIT Boulder 12 Inches or more Cobbles 3 to 12 Inches Coarse Gravel Y. to 3 Inches Fine Gravel No. 4 sieve to Y4 inch Coarse Sand No. 10 to No. 4 sieve Medium Sand No. 40 to No. 10 sieve Fine Sand No. 200 to No. 40 sieve Fines Smaller than No. 200 sieve 1 l . Definitions related to adjectives used in soil/rock descriptions: PROPORTION ADJECTIVE APPROXIMATE ROOT DIAMETER ADJECTIVE <5% Trace Less than 1/32" Fine roots 5% to 12% Little 1132" to''/o" Small roots 12% to 30% Some ''/a" to V Medium roots 30% to 50% And Greater than I" Large roots Organic Soils: Soils containing vegetable tissue in various stages of decomposition that has a fibrous to amorphous texture, usually a dark brown to black color, and an organic odor. Organic Content <25%: Slightly to Hi&ly Organic; 25% to 75%: Muck; >75%: Peat GFr � Appendix* D - Record of Test Borings 6FP GFA INTERNATIONAL 521 N.W. ENTERPRISE DRIVE, PORT ST. LUCIE, FLORIDA 34986 PHONE: (772) 924-3575 - FAx: (772) 924-3580 L CONE PENETRATION SOUNDING (ASTM D 3441) Client: Commercial Contracting Division, Inc. Date: 7/1/2014 Project No.: 14-0097.01 Project: Proposed Community Center Building at Savanna Club Lab No.: 3492 Crabapple Drive, St. Lucie County, FL Field Crew: PNI/WN Rig ID: OshKosh Location: CPT -1 N27.31587° W80.289170 Page: 1 of 1 Elevation: Existing Grade Field Data I 4, FR I (mP 7 14 4.7 0.2 10 15 20 13 0.4 25 27 50 2.6 0.6 20 30 40 1.7 0.8 40 45 8o 0.8 1.0 30 35 60 2.2 1.2 70 80 140 1.4 1.4 50 65 100 1.3 1.6 45 55 90 15 1.8 40 50 80 252.0 30 45 60 1.1 2.2 50 55 100 0.7 2.4 40 45 80 1.7 2.6 30 40 60 15 2.8 20 27 40 1.7 3.0 20 25 40 2.6 3.2 20 28 40 1.7 3.4 25 30 50 1.6 3.6 26 32 52 13 3.8 25 30 50 1.8 4.0 25 32 50 1.3 4.2 45 50 90 1.5 4.4 60 70 120 0.6 4.6 85 90 170 0.4 4.8 85 90 170 0.4 5.0 85 90 170 1.6 5.2 80 100 160 1.7 5.4 100 120 200 1.3 5.6 100 120 200 1.0 5.8 85 100 170 1.2 6.0 85 100 170 6.2 y 20 25 30 35 40 Cone Bearing, qc (tsf) Friction Ratio, FR 80 120 160 200 240 280 320 0 2 4 6 8 ,P. Wrojecis12014114-0097.01 Savanna Club Cmnnmrity Center (Commercial Contracting Divislon. lnc.)IGeoWppendicesWpp D - CPT-1 Page (20fl) GFA INTERNATIONAL 521 N.W. ENTERPRISE DRIVE, PORT ST. LuclE, FLOWDA 34986 PHONE: (772) 924-3575 - FAX: (772) 924-3580 CONE PENETRATION SOUNDING (ASTM D 3441) , Client: Commercial Contracting Division, Inc. Date: 7/1/2014 Project No.: 14-0097.01 Project: Proposed Community Center Building at Savanna Club Lab No.: 3492 Crabapple Drive, St. Lucie County, FL Field Crew: PM/WN Rig ID: OshKosh Location: CPT - 2 N27.316031 W80.289011 Page: 1 of 1 Elevation: Existing Grade Field Data q� (tsf) FR Depth (meters) p IP+S 10 20 33 0.2 15 20 30 4.4 0.4 25 35 50 2.6 0.6 80 90 160 1.7 0.8 90 110 180 0.7 1.0 100 110 200 1.0 1.2 75 90 150 13 1.4 35 50 70 2.8 1.6 40 55 80 1.7 1.8 45 55 90 iS 2.0 40 50 80 1.7 2.2 35 45 70 1.9 2.4 35 45 70 1.9 2.6 40 50 80 1.7 2.8 35 45 70 3.2 3.0 30 47 60 2.2 3.2 30 40 60 2.2 3.4 25 35 50 13 3.6 30 35 60 1.1 3.8 30 35 60 2.2 4.0 33 43 66 3.0 4.2 50 65 100 2.0 4.4 65 80 130 2.0 4.6 70 90 140 1.4 4.8 75 90 150 13 5.0 85 100 170 5.2 0 5 10 15 r w ,p 20 25 30 35 40 Cone Bearing, qc (tsf) Friction Ratio, FR 0 40 80 120 160 200 240 280 320 0 2 4 6 8 PAPro)ects12014114-0097.01 Savanna Club Conaumity Center (Commercial Contracting Division. 1na)1GeoWppendicesWpp D - CPT- I Page (20Ji) GFA INTERNATIONAL 521 N.W. ENTERPRISE DRIVE, PORT ST. LUCIE, FLORIDA 34986 PHONE: (772) 924-3575 - FAx: (772) 924 3580 I CONE PENETRATION SOUNDING (ASTM D 3441) Client: Commercial Contracting Division, Inc. Date: 7/1/2014 Project No.: 14-0097.01 Project: Proposed Community Center Building at Savanna Club Lab No.: 3492 Crabapple Drive, St. Lucie County, FL Field Crew: PNI/WN Rig ID: OshKosh Location: CPT - 3 N27.31617° W80.288791 Page: 1 of 1 Elevation: Existing Grade Field Data I ' (tsfl FR Depth (meters) P P+S 4 8 83 10 15 20 6.6 40 50 80 33 90 110 180 1.5 110 130 220 1.2 130 150 260 0.5 80 90 160 1.2 60 75 120 1.1 80 90 160 0.8 35 45 70 0.9 30 35 60 1.1 40 45 80 1.7 45 55 90 1.5 50 60 100 2.0 40 55 80 1.7 30 40 60 2.2 20 30 40 1.7 20 25 40 1.7 20 25 40 1.7 25 30 50 13 25 30 50 2.6 40 50 80 2.5 55 70 110 1.8 65 80 130 iS 70 85 140 1.4 75 90 150 13 65 80 130 IS 70 85 140 0.5 85 90 170 OA 55 60 110 1.2 80 90 160 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3A 3.6 3.8 4.0 4.2 4.4 4.6 4.8 5.0 5.2 5.4 5.6 51 6.0 6.2 0 5 10 15 ,p 20 25 30 35 40 Cone Bearing, qc (tsf) Friction Ratio, FR 0 40 80 120 160 200 240 280 320 0 2 4 6 8 P9Projectsl_7014114-0097.01 Savanna Club Community Center (Conmtercial Conlracling Division, btc.)IGeoWppendicesL4pp D - CPT- I Page (20ft) GFA INTERNATIONAL 521 N.W. ENTERPRISE DRIVE, PORT ST. LUCIE, FLORIDA 34986 PHONE: (772) 924-3575 - FAx: (772)_924 3580 L CONE PENETRATION SOUNDING (ASTM D 3441) Client: Commercial Contracting Division, Inc. Date: 7/1/2014 Project No.: 14-0097.01 Project: Proposed Community Center Building at Savanna Club Lab No.: 3492 Crabapple Drive, St. Lucie County, FL Field Crew: PM/WN Rig ID: OshKosh Location: CPT - 4 N27.316250 W80.288940 Page: 1 of 1 Elevation: Existing Grade Field Data 1 q� (tst) FR Depth (meters) P I P+S 4 8 83 0.2 10 15 20 33 0.4 45 50 90 1.5 0.6 60 70 120 1.1 0.9 80 90 160 0.8 1.0 80 90 160 1.7 1.2 65 85 130 2.0 1.4 50 70 100 2.0 1.6 35 50 70 1.9 1.8 35 45 70 2.8 2.0 35 50 70 2.8 2.2 55 70 110 1.2 2.4 60 70 120 1.7 2.6 30 45 60 2.2 2.8 25 35 50 13 3.0 20 25 40 1.7 3.2 15 20 30 2.2 3.4 15 20 30 2.2 3.6 20 25 40 1.7 3.8 25 30 50 13 4.0 25 30 50 2.6 4.2 30 40 60 33 4.4 40 55 80 2.5 4.6 60 75 120 1.7 4.8 60 75 120 2.2 5.0 70 90 140 5.2 Cone Bearing, qc (tsf) Friction Ratio, FR 0 40 80 120 160 200 240 280 320 0 2 4 6 8 0 l l , . l , . . 1 _ , _ 1 , . i K 15 25 30 35 40 PAProjecIA2014114-0097.01 Savanaa Chr6 Community Center (Commercial Contracting Division, lnc.) I GeoW ppendicesL4pp D -CPT -I Page (20jt) � , 1 GFA INTERNATIONAL 521 N.W. ENTERPRISE DRIVE, PORT ST. LUCIE, FLORIDA 34986 PHONE: (772) 924-3575 - FAx: (772) 924-3580 CONE PENETRATION SOUNDING (ASTM D 3441) I Client: Commercial Contracting Division, Inc.. Date: 7/1/2014 Project No.: 14-0097.01 Project: Proposed Community Center Building at Savanna Club Lab No.: 3492 Crabapple Drive, St. Lucie County, FL Field Crew: PM/WN Rig ID: OshKosh Location: CPT - 5 N27.316201 W80.289161 Page: 1 of 1 Elevation: Existing Grade Field Data 1 q� (tst) FR Depth (meters) P I P+S 9 18 3.7 0.2 10 15 20 3.3 0.4 25 30 50 2.6 0.6 50 60 100 1.3 0.8 80 90 160 0.8 1.0 90 100 180 1.1 1.2 70 85 140 1.4 1.4 50 65 100 1.3 1.6 30 40 60 2.2 1.8 27 37 54 2.4 2.0 50 60 100 1.3 2.2 55 65 110 1.8 2.4 45 60 90 2.2 2.6 40 55 80 1.7 2.8 40 5o 80 1.7 3.0 1 35 45 70 1.5 3.2 22 30 44 2.1 3.4 22 29 44 1.5 3.6 25 30 50 1.8 3.8 27 34 54 1.2 4.0 30 35 60 3.3 4.2 45 60 90 2.9 4A 65 85 130 0.5 4.6 15 85 90 170 0.8 4.8 90 100 180 0.7 5.0 90 100 180 5.2 y w v L� 20 a+ G. A 25 30 35 40 Cone Bearing, qc (tsf) Friction Ratio, FR 0 40 80 120 160 200 240 .280 320 0 2 4 6 8 P.Wrojects12014114-0097.01 Savanna C ib Conimmiity Center (Commercial Contracting Division, hic.)IGeoUppendicesUpp D - CPT- I Page (20fi) I Since 1988 - A FRNATIO� p to da's Leading Enghveer/rag Source AUGER BORING LOGS (ASTM D-1452)- Client: Commercial Contracting Division, Inc. Project No: 14-0097.01 Project: Proposed Community Center Building at Savanna Club Lab No: 3492 Crabapple Drive, St. Lucie County, FL Test Date: 7/1/2014 Elevation: Existing Grade Technician: PM/WM TEST LOCATION: AB@ CPT-1 Depth feet Description color, texture, consistency, remarks 0-1 Brown fine sand SP 1-2 Gray fine sand SP 2-3 Light gray fine sand SP 3-4 Gray fine sand SP 4-5 Dark brown organically stained fine sand, some silt (hardpan) SM Water table at 5 feet below ground surface TEST LOCATION: AB CPT-2 Depth feet Description color, texture, consistency, remarks 0-2 Brown fine sand, little silt SPSM 2-3 Light gray fine sand SP 3-4 Gray fine sand SP 4-5 Dark brown organically stained fine sand, some silt (hardpan) SM Water table at 4 feet below ground surface TEST LOCATION: AB CPT-3 Depth feet Description color, texture, consistency, remarks 0-3 Brown fine sand, little silt SP-SM 3-4 Light gray fine sand SP 4-5 Dark brown organically stained fine sand, some silt (hardpan) SM Water table at 3'/ feet below ground surface Since 1988 Florida's Leadir)g TEng1heefrr:g Source I AUGER BORING LOGS (ASTM D-1452) I Client: Commercial Contracting Division, Inc. Project No: Project: Proposed Community Center Building at Savanna Club Lab No: 3492 Crabapple Drive, St. Lucie County, FL Test Date: Elevation: Existing Grade Technician: 14-0097.01 7/1/2014 PMMM TEST LOCATION: AB@ CPT-4 Depth feet Description color, texture, consistency, remarks 0-3 Brown fine sand SP 3-4 Light gray fine sand SP 4-5 Dark brown organically stained fine sand, some silt (hardpan) SM Water table at 2Y2 feet below ground surface TEST LOCATION: AB@ CPT-5 Depth feet Description color, texture, consistency, remarks 0-3 Brown fine sand SP 3-4 Light gray fine sand SP 4-5 Dark brown organically stained fine sand, some silt (hardpan) SM Water table at 3'/ feet below ground surface Appendix E - Discussion of Soil Groups GFi� DISCUSSION OF SOIL GROUPS COARSE GRAINED SOILS GW and SW GROUPS. These groups comprise well -graded gravelly and sandy soils having little or no plastic fines (less than percent passing the No. 200 sieve). The presence of the fines must not noticeably change the strength characteristics of the coarse -grained friction and must not interface with it's free -draining characteristics. GP and SP GROUPS. Poorly graded gravels and sands containing little of no plastic fines (less than 5 percent passing the No. 200 sieve) are classed in GP and SP groups. The materials may be called uniform gravels, uniform sands or non -uniform mixtures of very coarse materials and very fine sand, with intermediate sizes lacking (sometimes called skip -graded, gap graded or step - graded). This last group often results from borrow pit excavation in which gravel and sand layers are mixed. GM and SM GROUPS. In general, the GM and SM groups comprise gravels or sands with fines (more than 12 percent the No. 200 sieve) having low or no plasticity. The plasticity index and liquid limit of soils in the group should plot below the "A" line on the plasticity chart. The gradation of the material is not considered significant and both well and poorly graded materials are included. GC and SC GROUPS. In general, the GC and SC groups comprise gravelly or sandy soils with fines (more than 12 percent passing the No, 200 sieve) which have a fairly high plasticity. The liquid limit and plasticity index should plat above the "A" line on the plasticity chart. FINE GRAINED SOILS ML and MH GROUPS. In these groups, the symbol M has been used to designate predominantly silty material. The symbols L and H represent low and high liquid limits, respectively, and an arbitrary dividing line between the two set at a liquid limit of 50. The soils in the ML and MH groups are sandy silts, clayey silts or inorganic silts with relatively low plasticity. Also included are loose type soils and rock flours. CL and CH GROUPS. In these groups the symbol C stands for clay, with L and H denoting low or high liquid limits, with the dividing line again set at a liquid of 50. The soils are primarily organic clays. Low plasticity clays are classified as CL and are usually lean clays, sandy clays or silty clays. The medium and high plasticity clays are classified as CH. These include the fat clays, gumbo clays and some volcanic clays. crp OL and OH GROUPS. The soil in the OL and OH groups are characterized by the presence of organic odor or color, hence the symbol O. Organic silts and clays are classified in these groups. The materials have a plasticity range that corresponds with the ML and MH groups. HIGHLY ORGANIC SOILS The highly organic soils are usually very soft and compressible and have undesirable construction characteristics. Particles of leaves, grasses, branches, or other fibrous vegetable matter are common components of these soils. They are not subdivided and are classified into one group with the symbol PT. Peat humus and swamp soils with a highly organic texture are typical soils of the group. Gf�