Loading...
HomeMy WebLinkAboutEngineering CBUCK 'E=riginL=L=rinq Y CBUCK,Inc.Certificate of Authorization#18064 SpPCldlty Structurcal E=nq�lrlPPrlrlg3 Evaluation Report "Englert° Series 2000" Metal Roof Assembly Manufacturer: Englert, Inc. 1200 Amboy Avenue Perth Amboy, NJ 08862 (732)826-8614 for Florida Product Approval # FL 11751.2 113' Florida Building Code 5th Edition (2014) Method: 1 - D Category: Roofing Sub - Category: Metal Roofing Product: "Series 2000" Roof Panel Material: Aluminum Panel Thickness: 0.032" - Panel Width: 18" Panel.Seam:• 'Snap-Lock Support: Wood Deck Prepared by: seu rctWaonk seNrwt mex swam James L. Buckner, P.E.,SECB L $uc� ,�� Florida Professional Engineer#31242 aP•. ti�ovsF ..F�; Florida Evaluation ANE ID: 1916 =*: No31242 Project Manager: Diana Galloway Report No. 15-126-2000-A3W-ER `. STATE OF (Revises 12-171-2000-A3W-ER) '�,FS,'•FLo��oP.•`C��=� Date: 4/2/ 15 F f(Al Contents: t Evaluation Report Pages 1=8 . t8gita1lV Ngned M:Ja;nes t.@�rtncc P,E. CBUCK, Inc. 2015.04.27 09:58:14-04'00' 1399 N.Killian Drive,Suite 4,West Palm Beach,Florida 33403 Phone:(561)491-9927 Fax:(561)491-9928 Website:www.cbuckinc.net FL#: FL 11751.2 R3 Date: 4/2/15 Cps CK &nglineerin g Report No.: 25of2S6-2000-A3W-ER i �6..J 1� - 1 1 - SpeGdlty Structurcdl E=hgIneering CBUCK,Inc.Certificate of Authorization#8064, Manufacturer: Englert,Inc. Product Name: "Series 2000" Product.Category: _Roofing Product Sub-Category Metal Roofing Compliance Method:' State Product Approval Rule" 61G20-3.005 (1) (d) Product/System "Series 2000 Roof Panel Description: 0 032" Aluminum Snap-Lock roof panel mechanically !attached to Wood Deck . with fixed panel clips&screws.. Product Assembly as Refer to Page 4 of this report for'product assembly components/materials & Evaluated: standards. .- 1. Roof Panel 2.. Panel Clip 3. Fasteners 4. Underlayment 5. Insulation (Optional) Support: Type: Wood Deck (Design of support and its attachment to support framing is outside the scope of this evaluation.) Description' - ' • 15/32".,or 19/32" or greater plywood (Per Table A), • or Wood, plank(min. specific gravity of 0.42) - Slope: Minimum slope shall be; 3 : 12 or greater In 'compliance with, FBC. Chapter 15 based on .the type of roof covering, applicable- ,.code sections and- in accordance with - manufacturer's recommendations... Performance: Wind Uplift Resistance: ' • "Design Uplift Pressure: " See Table'"A" (Refer to"Table A" attachment details herein) FL#: FL 11751.2 R3 Date: 4/2/15 CBUCK ngineerin� Pagert No.:3 of8 2000-A3W-ER ;r i Specialty Structural Englm -ring CBUCK,Inc.Certificate of Authorization If8064 Performance The product described herein has demonstrated compliance with: Standards: • U L580-06—Test for Uplift Resistance of Roof Assemblies • U L 1897-04—Uplift test for roof covering systems • TAS 125-03—Standard Requirements for Metal Roofing Systems Standards Equivalency: The UL 580-94 & UL 1897-98 standard version used to test ,the evaluated product assembly is equivalent with the prescribed standards in UL 580-06 & UL 1897-04 adopted by the Florida Building Code 5th Edition (2014). Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 5th Edition (2014), Section 1504.3.2. Evaluation Report This building envelope product is evaluated for compliance with the structural Scope: requirements of the Florida Building Code, per the scope sections of Florida Product Approval Rule 61G20-3.001. Limitations and Scope of"Limitations and Conditions of Use"for this evaluation: Conditions of Use: This evaluation report for"Optional Statewide Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 9N-3.005. Per Rule 9N-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval'. • Option for application outside "Limitations and Conditions of Use" Rule 9N-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: 'The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID#QUA 1824). C � ' FL#: FL 11751.2 R3 Date: 4/2/15 CBUCK Engineering Page Report No.:4of8 -2000-A3W-ER r it Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Components/Materials Roof Panel: Englert Series 2000 (by Manufacturer): Material: Aluminum Thickness: 0.032" (min.) Panel Widths: 18" (max.) Coverage Rib Height: 1-3/4" Alloy Type: 3105 H14 Corrosion Resistance: Per FBC Section 1507.4.3 Roof Panel Clips: Product Name: Englert"Series 2000 Clip" Englert Part#: 05076B Type: One-piece,fixed clip Material: Galvanized Steel Thickness: 18 gauge Yield Strength: 40 ksi min. Dimensions: 1-3/4 (tall)x 3-1/2" (long)x 2-1/2" (wide) Corrosion Resistance: Per FBC Section 1506.7 Fastener: Type:. Pancake-Head Wood Screw Size : #10 x 1" Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.1 Components& Underlayment: Materials: Material and application shall be in compliance with FBC Chapter 15 based on the (by Others) type of roof covering, applicable codes and in accordance with manufacturer's recommendations. Insulation (Optional): Type: Rigid Insulation Board Thickness: 3" (max.) Properties: Density: 2.25 pcf(lbs/ft3) min. Or Compressive Strength: 20 psi min. Insulation Notes: • Rigid Insulation shall meet minimum density OR compressive strength. • Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". FL#: FL 11751.2 R3 Date: 4/2/15 CBUCK .ngineerinC) Report No.:5 -12 -2000-A3W-ER of 8 Y SpeclaltLj Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Installation: Installation Method: (Refer to"TABLE A" below and drawings at the end of this evaluation report.) ■ Clip Spacing: Refer to"TABLE A" Below (along the length of the panel) ■ Two (2)fasteners per Clip ■ Rib Interlock: Snap-Lock (Panel ribs shall be fully engaged to form an integral snap-lock.) ■ Minimum fastener penetration thru bottom of support, 3/16". ■ For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE"A" ALLOWABLE LOADS Min.Deck Clip #Fasteners Design Thickness Spacing per Clip Pressure METHOD 1 15/32" 18" 2 -82.5 PSF METHOD 2 15/32" 12" 2 -123.75 PSF METHOD 3 15/32" 6" 2 -180 PSF METHOD 4 1 19/32" 1 16" 2 - 107 PSF Notes: • Allowable design pressure(s)for allowable stress design(ASD).. Install the "Series 2000" roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 5th Edition (2014). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Referenced Data: 1. TAS 125-03 (UL580/UL1897) Uplift Test By Architectural Testing, Inc. (FBC Organization ID#TST 1558) Report#: B8193.02-109-18-r1, Dated: 10/16/12 - 2. TAS 125-03 (UL580/UL1897) Uplift Test By Architectural Testing, Inc. (FBC Organization ID#TST 1558) Report#: 92992.01-109-18, Dated: 7/16/10 3. TAS 125 Uplift Test By Hurricane Test Laboratory, LLC(FBC Organization ID#TST 1527) Report#0155-0510-05, Specimen#1, Date: 5/23/05 4. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID#QUA 1824) Englert, Inc. Licensee#420 5. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering 6. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering �* FL#: FL 11751.2 R3 Date: 4/2/15 CBUCK Engineering Pagert No.:6 -18 -2000-A3W-ER SpeClalty Structural EnglnePrinq CBUCK,Inc.Certificate of Authorization#8064 Installation Method Englert, Inc. "Series 2000" (0.032" Aluminum) Roof Panel attached to Wood Deck Drawings 18" Coverage 1-3/4" Typical Panel Profile 1 e Cn ` '> v2a CLIP s ��z• Panel Clip Profile Englert "Series 2000 Clip" (Part # 05076B) FL#: FL 11751.2 R3 Date: 4/2/15 C LJCK Engineering R port No.:7 -12 -2000-A3W-ER of 8 j rSpE-CIca5ItLj Structural EnglnePrinq CBUCK,Inc.Certificate of Authorization#8064 Installation Method Englert, Inc. "Series 2000" (0.032" Aluminum) Roof Panel attached to Wood Deck 18" Clips with TWO#10 CPancake-Head Screws Integral Snap Lock HI � Wood Deck Clips with TWO#10 Pancake-Head Screws 7Wbod Deck Typical Assembly Profile View (Typical Fastening Pattern Across Width) - FL#: FL 11751.2 R3•~' --;v 1 Date: 4/2/15 C UCK engineering Page ReportNo.:8 -12 -2000-A3W-ER of 8 Spealalty Structural Englneerinq CBUCK,Inc.Certificate of Authorization##8064 Installation Method Englert, Inc. "Series 2000" (0.032" Aluminum) Roof Panel attached to Wood Deck Two#10 Pancake-Head "Series 2000"Panel Screws per Clip rr I►a $ir 114 �e - -- Panel Clip r r' r rr .r r 18" Wood Deck Typical Roof Assembly Isometric View (Optional) Rigid Insulation Board per Page 4 of this report TABLE"A" Min.Deck Clip #Fasteners Design Thickness Spacing per Clip Pressure METHOD 1 15/32" 18" 2 -82.5 PSF METHOD 2 15/32" 12" 2 -123.75 PSF METHOD 3 15/32" 6" 2 -180 PSF METHOD 4 19/32" 16" 2 -107 PSF FL#: FL 11751.2-R2 1 Date: 10 f 23112 _ Report No.:32-17120CIO-A3W-ER Page 8 of 8 Sp �f'y S!'i f'>,te3�. Enq pt CDR%Ix cerdflcaWcf a a., 1 Installation Method Pnglart, Ins "Series 2OW (o o32n Aluminum)•Roof Panel attached to Wood Deck Two#10 Panes 'Suies 2at10°Panel Saetnrs per Clip W � Panel cup Wood Deck Typical Roof Assembly Isometric View (OptionaQ Rigid insulation Board per Page 4 of this report TABLE uA" Min.Deck clip #Fasteners Design Thickness Spacing per dip Pressure' METHOD 1 15/3r 18" 2 -8Z.5 PSF METHOD 2 15/3r 1r 2 -123.75 PSF eA _ METHOD 3 15�32 En 2 -180 PSF MET- OD 4 19/32" IV 2 -107 PSE AbdoAic! I' L v 7503-8.Indian River Drive '. Fort i?ierce,Florida FEB 2 7 2011 PAtAWl3 I,VIE PCi#3518-2-12-0©8ZW