HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 3
-7
r
1 �
. �`' ��
BCIS Home Log In ; User Registration Hot Topics Submit Surcharge I Stats&Facts Publications FBC Staff BCIS Site Map Links Search
r_o;lLa CONCEALED FASTENERS OR ATTACHMENTS
Product UT USER:Public User al '
ARE THE RESPONSIMP OF THE
b. . _ .
Product ApprovalOF REC9RD Aooroval.Menu>Product or Application Search>Application List>Application Detail ,
FL# FL11651-112
Application Type Revision THESE FLANS AND ALL PROPOSED WORK
.Code Version 2014
Application Status Approved ARE SUBJECT-TOAI�IY CORRECTION
REQUIRE®BY-FIELD INSPECTORS THAT.
Comments "`�`«, 7idld'IY•�I:1'1111,�5ry�gEe�p'YAlRH� ��9R76AbyyI��;T�pV::"'z
Archived
Product Manufacturer Gulf Coast Supply&Manufacturing,LLC.
Address/Phone/Email 4020 S.W. 449th Street
Horseshoe Beach, FL 32648
(352)498-7852
ray@gulfcoasts upply.com
Authorized Signature Ray Bowen
ray@gulfcoasts upply.com
dry 0�t
Technical Representative St t,t1Cto-1)IN T!'QUITD�`G?DIVISION
Address/Phone/Email R-WrI IED FOR COIN CE
Quality Assurance Representative DATA—C"A I
Address/Phone/Email PLANS MENU MUST BE MPT ON JOB
OR NO IN8PECTd.ON, WM-L OV,WL-DE,
Category Roofing
Subcategory Metal Roofing
Compliance'Method Evaluation Report from a Florida Registered Architect or a
Licensed Florida Professional Engineer
0 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Daniel S.Kuhn.
Evaluation Report
Florida License PE-75519
Quality Assurance Entity ,Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/12/2024
Validated By Locke Bowden
0 Validation Checklist-Hardcopy Received
Certificate of Independence FL11651 'R2 COI'Cert of Ind Kuhn Eno.odf
FL11651 R2.COI Letter of Name chanoe.odf
.Referenced Standard,and Year(of Standard) Standard - Year
FM 4471 1992
TAS 100 1995
TAS 110' 2000'
TAS 125 2003
UL 1897 2004
UL 580 2006-
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr_app dtl.aspx?param=wOEVXQwtDgsQFc5K%2f Tr... . 2/10/2017
Florida Building Code Online Page,2 of 3
Y'
Product Approval Method Method 1 Option D
Date Submitted 07/01/2015
Date Validated 07/10/2015
Date Pending FBC Approval 07/18/2015
Date Approved 08/18/2015
Summary of Products
Go to Page it Page 2/2 V7
FL# Model,Number or Name Description
11651.21 26 Ga. GulfRib, 26 Ga.GulfRib over 1x4 Wood Purlins over'15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R2 II 21 R2 26GulfRib 1x4 15-32Plvwood NonHVHZ.Ddf
Approved for use outside HVHZ: Yes FL11651 R2 II 21 R2 Metal Roof Panel Detail.pdf
Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-164.2PSF Created by Independent Third Party:Yes
Other: -109.25 psf @ 24"o.c.fastener spacing. Evaluation Reports
-164.25 psf @ 12" fastener spacing. Install per FL11651 R2 AE 21 R2 26GulfRib 1x4 15-32Plvwood NonHVHZ.pdf
manufacturer's details. Not for use in HVHZ Created by Independent Third Party: Yes
Zones
11651.22 26 Ga. GulfRib 26 Ga.GulfRib over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R2 II 14FL11651 22 R2 26GulfRib 15-
Approved for use outside HVHZ: Yes 32Plvwood NonHVHZ.Ddf
Impact Resistant: N/A FL11651 R2 II 22 R2 Metal Roof Panel Detail.pdf
Design Pressure: +N/A/-159.2PSF Verified By: Dan Kuhn,P.E.75519
Other:-69.25 psf @ 24"o.c.fastener spacing. Created by Independent Third Party: Yes
-159.25 psf @ 12" fastener spacing. Install per Evaluation Reports
manufacturer's details.Not for use in HVHZ FL11651 R2 AE 14FL11651 22 R2 26GulfRib 15-
Zones 32Plvwood NonHVHZ.pdf
Created by Independent Third Party: Yes
11651.23 26 Ga. GulfRib 26 Ga.GulfRib over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL11651 R2 II 23 R2 26GulfRib 15-32Plvwood HVHZ.Ddf
Approved for use outside HVHZ: Yes FL11651 R2 II 23 R2 Metal Roof Panel Detail.pdf
Impact Resistant: N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure: +N/A/-159.2PSF Created by Independent Third Party: Yes
Other:-71.75 psf @ 24"o.c. fastener spacing. Evaluation Reports
-159.25 psf @ 12" fastener spacing. Install per FL11651 R2 AE 23 R2 26GulfRib 15-32Plvwood HVHZ.pdf
manufacturer's details. For use-in HVHZ Zones Created by Independent Third Party: Yes
11651.24 26 Ga. GulfRib 26 Ga.GulfRib over 1x4 Wood Purlins over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL11651 R2 II 24 R2 26GulfRib 1x4 15-32Plvwood HVHZ.odf
Approved for use outside HVHZ: Yes FL11651 R2 II 24 R2 Metal Roof Panel Detail.odf
Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-164.2PSF Created by Independent Third Party: Yes
Other:-106.75 psf @ 24"o.c.fastener spacing. Evaluation Reports
-164.25 psf @ 12" fastener spacing. Install per FL11651 R2 AE 24 R2 26GulfRib 1x4 15 32Plvwood HVHZ.pdf
manufacturer's details. For use in HVHZ Zones Created by Independent Third Party:Yes
11651.25 29 Ga. GulfRib 29 Ga.GulfRib over 1x4 Wood Purlins over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R2 II 25 R2 29GulfR1b 1x4 1S-32Plvwood NonHVHZ.pdf
Approved for use outside HVHZ: Yes FL11651 R2 II 25 R2 Metal Roof Panel Detail.pdf
Impact Resistant: N/A Verified By: Dan Kuhn, P.E.75519
Design Pressure: +N/A/-123.SPSF Created by Independent Third Party: Yes
Other:-76.75 psf @ 24"o.c. fastener spacing. Evaluation Reports
-123.5 psf @ 24" fastener spacing. Install per FL11651 R2 AE 25 R2 29G ulfRib 1x4 15-32Plvwood NonHVHZ.Ddf
manufacturer's details. Not for use in HVHZ Created by Independent Third Party: Yes
Zones
11651.26 29 Ga. GulfRib 29 Ga.GulfRib over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R2 II 26 R2 29GulfRib 15-32Plvwood NonHVHZ.pdf
Approved for use outside HVHZ: Yes FL11651 R2 II 26 R2 Metal Roof Panel Detail.pdf
Impact Resistant: N/A Verified By: Dan Kuhn, P.E.75519
i
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f rr... 2/10/2017