FL #FL11602-R10
Application Type
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning Roofing and Asphalt, LLC
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43645
(740)321-6345
Greg. Keeler@owenscorning.com
Authorized Signature Keeler Greg
Greg.Keeler@owenscorning.com
Technical Representative Greg Keeler
Address/Phone/Email 2790 Columbus Road
Granville, OH 43023
(740) 321-6345
greg.keeier@owenscorning.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE -59166
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2020
Validated By John W. Knezevich, PE
„' Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL11602 R10 COI 2019 01 COI NIEMINEN pdf
Standard
Year
ASTM D1970
2015
ASTM D226 (physicals)
2009
ASTM D4798
2011
FRSA/TRI April 2012
2012
TAS 117(6)
1995
UL1897
2012
https.Ilwww.floridabuilding.orglpr/pr app_dti.aspx?param=wGEVXQwtDgsQFG5Kp/o2fTrZeHYB7UCe5KMr%2fsMfWgra38u9whFr5gP6KA%3d%3d 112
3116/2020
Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
10/17/2019
Date Validated
10/17/2019
Date Pending FBC Approval
10/20/2019
Date Approved
12/10/2019
i PL Model, number or Name 'Description
j
316.1 Titanium Roof Underlayments synthetic sheet -type roof underiayments
f-�flfilt5 of Use
Approved for use in tfVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/ -45
Other: 1,) The design pressure noted herein pertains to use of
a specific underlayment system beneath foam -on the sytserns.
Refer to ER Section 5.6.3 for details. 2.) Refer to ER Sections 5
and 6 for other Limits of Use.
Installation Instructions
FL11602 RIO II 2019 SO FINAL ER FL11602-R1O.odf
Verified By: Robert Nieminen PE -59166
Created by Independent Third Party: Yes
Evaluation Reports
FL11602 RIO AE 2019 10 FINAL ER FL11602-RIO.odf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee R 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Qpydght 2007-2013 State of Florida.:: Privacy Statement r.. Accessibility Statement :: Refund Statement
Under Florida lava, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1),
Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be madeavailable to the public. To determine if you are a licensee under Chapter 455, F..S., please dick hexa .
Product Approval Accepts:
https.-Ilwww.to(idabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeHYB7UCe5KMr°lo2fsMfWgra38u9whFr5gP6KA°kid%3d 212
EMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
Owens Corning Roofing and Asphalt, LLC Evaluation Report 111980.11.08-1111
One Owens Corning Parkway FL11602-1110
Toledo, OH 43659 Date of Issuance: 11/03/2008
(740) 321-6345 Revision 11: 10/17/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: TitaniumT' Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEIVIOIetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
.a
Robert J.M. Nieminen, P.E.
The facsimile seal appearing was authorized by Robert
Florida Registration No, 59166, Florida DCA ANE1983 Nieminen, P.E. on 10/17/2019. This does not serve as an
CERTIFICATION Of INDEPENDENCE: electronically signed document.
1, NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2, NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
i]2018 NEMO ETC, LLC
(1Z1'NEM0JetC,
t
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: TitaniumTm Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC,
have demonstrated compliance with the intent of the following sections of the 611 Edition (2017) Florida Building
Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the
Installation Requirements and Limitations / Conditions of Use set forth herein.
Section
PropertV
Standard
Year
1504.3.1
Wind Uplift
UL 1897
2012
1507.1.1, R905.1.1 Exception
Unrolling, Breaking Strength, Pliability
ASTM D226
2009
1507.1.1, R905.1.1 Exception
Tear Strength
ASTM D1970
2015
1507.1.1, T1507.1.1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
TAS 110
Accelerated Weathering
ASTM D4798
2011
TAS 110
Pull-through resistance
TAS 117(8)
1995
IRE
Entity
Examination
Reference
Date
ERD (TST6049)
Physical Properties
115010.04.09
04/29/2009
ERD (TST6049)
Physical Properties
115010.05.10
05/14/2010
ERD (TST6049)
Physical Properties
135520.06.11
06/15/2011
ERD (TST6049)
ASTM D226
138010.08.11
08/11/2011
ERD (TST6049)
Wind Uplift
135520.08.11-1
08/12/2011
ITS(TST1509)
ASTM D226
311801000Q-003
04/26/2007
ITS(TST1509)
ASTM D226
3130639COQ-002A
08/21/2007
ITS (TST1509)
Physical Properties
3126617COQ-005
10/31/2007
ITS (TST1509)
ASTM D226
101823107COQ-011
01/23/2015
ERD (TST6049)
Physical Properties (NH)
4j-OC-19-SSUDL-01.A
06/14/2019
Owens Corning
Product equivalency
Declaration
06/18/2018
PRI (TST5878)
ASTM D1970
OCF-341-02-01
09/20/2017
PRI (TST5878)
ASTM D1970; Tear strength
OCF-331-02-02
10/03/2017
PRI (TST5878)
ASTM D1970; Tear strength
OCF-332-02-02
10/03/2017
PRI (TST5878)
ASTM D1970; Tear strength
OCF-334-02-02
10/03/2017
PRI (TST5878)
FRSA/TRI April 2012 (04-12), partial
OCF-343-02-01
11/09/2017
PRI (TST5878)
ASTM D4798
OCF-341-02-01
11/27/2017
PRI (TST5878)
TAS 117(B); Pull-through
OCF-422-02-02
04/03/2018
PRI (TST5878)
FRSA/TRI April 2012 (04-12), partial
OCF-425-02-01
08/13/2018
PRI (TST5878)
ASTM D226 / ASTM D4798
OCF-331-02-01 R1
05/07/2019
PRI (TST5878)
ASTM D226 / ASTM D4798
OCF-332-02-01 R1
05/07/2019
PRI (TST5878)
ASTM D226 / ASTM D4798
OCF-334-02-01 R1
05/07/2019
PRI (TST5878)
UL1897
1378TO02
07/10/2019
PRI (TST5878)
Tensile adhesion
OCF-507-02-01
08/13/2019
ITS (QUA1673)
Quality Control
ITS Listings
Current
ITS (QUA1673)
Quality Control
Service Confirmation
09/30/2017
NEMO ETC, LLC Evaluation Report 111980.11.08-R11
Certificate ofAutharization #32455 6TN EDITION (2017) FBC NON-HVHZ EVALUATION FL11502-R10
Titanium Roof Underlayments Revision 11:10/17/2019
Page 2 of 8
4.1
Product
Titanium'"" PSU-30
Specification
ASTM D1970
and FRSA/TRI
April 2012
Plants Description
Dubai, UAE & unreinforced polymer modified bitumen material adhered
Brentwood, NH to the underside of a polymer -coated, synthetic woven
sheet. The underside is backed with a release film. Unit
weight 24 lbs/square
4.2 TitaniUMTM UDL-25 FBC 1507.1.1
Qingdao, China
synthetic sheet -type underlayment comprised of a woven
& R905.1.1
core coated on one side with a polymer coating. Unit
(Exception)
weight 2.5 lbs./square
4.3 Titanium'"" UDL-30 FBC 1507.1.1
Mission, BC,
synthetic sheet -type underlayment comprised of a woven
& R905.1.1
Canada &
core coated on both sides with a polymer coating. Unit
(Exception)
Qingdao, China
weight 4.0 lbs./square
4.4 TitaniUMTM UDL-50 FBC 1507.1.1
Mission, BC,
synthetic sheet -type underlayment comprised of a woven
& R905.1.1
Canada &
core coated on both sides with a polymer coating. Unit
(Exception)
Qingdao, China
weight 4.7 lbs./square
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Titanium'" Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction
for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Asphalt
Wood Shakes
y ent
Shingles
Nail -On Tile
Metal
& Shingles
Siate
:Titaniu!mP-30
Yes
Yes
EFoam-On'lrlfle
Yes
Yes
Yes
um UDL-25
Yes
No
No
Yes
Yes
Yes
Titanium UDL-30
Yes
Yes
Yes
(Base Sheet in 2 -ply
(Base Sheet in 2 -ply
Yes
Yes
yes
system)
system)
Titanium UDL-50
Yes
No
No
Yes
Yes
Yes
NEMO ETC' LLC Evaluation Report 111988.11.08-RSl
Certificate o}Authadwtion#32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R10
Titanium Roof Underiayments Revision 11:10/17/2019
Page 3 of 8
5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives/ underlayment combinations.
5.6
5.6.1
TABLE 1A: ALLOWABLE TiLE ADHESIVE/ UNDERLAYMENT COMBINATIONS'
Underlayment Adhesive Florida Product Approval
DUPONT Tile Bond -
Titanium PSU-30 iCP Adhesives Polyset- AH -160
ICP Adhesives Polyset® RTA -1
Allowable Substrates (for self -adhering):
FL22525
FL6332
FL6276
TABLE 2: SUBSTRATE OPTIONS
Underlayment
Primer Substrates
Titanium PSU-30
(Optional) ASTM D41 plywood
None ASTM D226 felt
ASTM D41 Titanium UDL-30
None Titanium UDL-30 (inverted)
#1
#2
Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April
2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
Maximum Design Pressure = -45 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTM D41
Underlayment: One or two plies, Titanium PSU-30, self -adhered and back -nailed max. 6" o.c. with 12 ga.
galvanized annular rink shank nails through 32 ga., 1 -5/8 -inch diameter tin caps in accordance with
Owens Corning Roofing and Asphalt, LLC published installation requirements.
Maximum Design Pressure = -30 psf*:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (inverted)
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16 -inch
with min. 32 ga., 1-5/8" diameter tin caps
Spacing: 6 -inch o.c. at 4 -inch wide side laps and 12 -inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required at all tin -caps.
Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized
annular rink shank nails through 32 ga., 1 -5/8 -inch diameter tin caps in accordance with Owens
Corning Roofing and Asphalt, LLC published installation requirements.
' Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance
NEMO ETC, LLC Evaluation Report 111980.11.08-Rll
Certificate of Authorization 1132455 6i" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-1110
Titanium Roof Underlayments Revision 11:10/17/2019
Page 4 of 8
#3 Maximum Design Pressure = -30 psf*: ONEMO I eta.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (printed side up)
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga., 1-5/8" diameter tin caps.
Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required over printed side of UDL-30.
Underlayment: One or two plies, Titanium PSU 30, self-adhered and back-nailed max. 6" o.c. with 12 ga. galvanized
annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens
Corning Roofing and Asphalt, LLC published installation requirements.
44 Maximum Design Pressure = -45 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (inverted)
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga., 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required at all tin-caps.
Underlayment: One or two plies, Titanium PSU 30, self-adhered and back-nailed 6" o.c. with 12 ga. galvanized
annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens
Corning Roofing and Asphalt, LLC published installation requirements.
#5 Maximum Design Pressure = -45 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (printed side up)
Fasteners: 12 ga, annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga., 1-5/8" diameter tin caps.
Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required over printed side of UDL-30.
Underlayment: One or two plies, Titanium PSU 30, self-adhered and back-nailed 6" o.c. with 12 ga. galvanized
annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens
Corning Roofing and Asphalt, LLC published installation requirements.
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table IA.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. Zones 2 and 3 shall employ an attachment density designed by
a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI
WDI, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an
asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016)
for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Titanium UDL-25, Titanium UDL-30, Titanium UDL-50 or Titanium PSU-30 shall not be left exposed for longer than
180 -days.
NEMO ETC, LLC Evaluation Report 111980.11.08-R11
Certificate of Authorization #32455 6T" EDITION (2017) FSC NON-HVHZ EVALUATION FL11602-RSO
Titanium Roof Underlayments Revision 11:10/17/2019
Page 5 of 8
5.8
6.1
6.2
6.3
6.3.1
6.3.2
6.3.2.1
Tile Slippage Limitations (per FRSA/TRI ADM 2012 (04-12)1
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 3: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile Staging Method
Maximum Slope
Titanium PSU-30
Flat Max. 10 the stack
5:12
Flat Max 5 -tile stack
6:12
Lugged Max. 10 -tile stack
4:12
Lugged Max. 5 -tile stack
5:12
Lugged
Max. 10 -tile stack (5 over 51
5:12
Titanium Roof Underlayments shall be installed in accordance with Owens Corning Roofing and Asphalt, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted
below.
Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
Titanium'"" UDL-25, Titanium UDL-30 or Titanium UDL-S0:
Shall be installed in compliance with the requirements for ASTM D226, Type I or 11 underlayment in FBC Table
1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width.
Fasteners:
Mechanical attachment of Titanium UDL-25 and Titanium UDL-30 is limited to ring shank roofing nails with
minimum 1 -inch diameter plastic caps.
Mechanical attachment of Titanium UDL-50 is limited to ring shank roofing nails with minimum 3/8 -inch diameter
heads; ring shank roofing nails with minimum 1 -inch diameter plastic caps; screws and plates; or plastic cap staples.
Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails shall
be required where the ultimate design wind speed, Vault, equals or exceeds 150 mph."
Owens Corning Roofing and Asphalt, LLC has furnished data to permit the use of 1 -inch diameter plastic cap nails
in lieu of metal cap nails for these applications, when the TitaniumTm UDL-25, Titanium UDL-30 or Titanium UDL-50
underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1
or R905.1.1.
MEMO ETC, LLC Evaluation Report 111980.11.08-R1I
Certificate of Authorization #32455 67" EDITION (2017) FSC NON-HVHZ EVALUATION FL11602-R30
Titanium Roof Underlayments Revision 11:10/17/2019
Page 6 of 8
6.3.3
6.3.4
Slopes of 4:12 or greater:
folINEM0 I eti
End (vertical) laps shall be minimum 6 -inches and side (horizontal) laps shall be minimum 4 -inches. End (vertical)
laps shall be offset from course to course not less than 6 feet.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. When batten systems are to be
installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the
battens.
Slopes of 2:12 to less than 4:12:
End (vertical) laps shall be minimum 12 -inches and side (horizontal) laps shall be minimum 25 -inches. End (vertical)
laps shall be offset from course to course not less than 6 feet.
Begin by fastening a 25 -inch wide strip along the eaves. Place a full -width sheet over the starter, completely
overlapping the starter course. Continue upslope, maintaining minimum 25 -inch side (horizontal) laps, resulting in
a double -layer application.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or 8905.1.1. Secure end laps 4 -inch o.c.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of the battens.
6.4 Titanium;"' PStt-30:
6.4.1 Non -Tile Installations:
Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed, and Owens Corning published requirements.
Titanium"' PSU-30 shall be back -nailed in accordance with Owens Corning published installation requirements.
6.4.2 Nail -On Tile Applications:
Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in
FRSA/TRI April 2012 (04-12), and Owens Corning published requirements. Titanium"' PSU-30 shall be back -nailed
max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1 -5/8 -inch diameter tin caps in
accordance with Owens Corning published installation requirements.
Refer to Section 5.8 for tile staging limitations.
6.4.3 Foam -On Tile Applications:
Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in
FRSA/TRI April 2012 (04-12), and Owens Corning published requirements. Titanium' PSU-30 shall be back -nailed
max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1 -5/8 -inch diameter tin caps in
accordance with Owens Corning published installation requirements.
Refer to Table 1A for allowable tile adhesives.
Refer to Section 5.6.1 for wind uplift limitations.
Refer to Section 5.8 for the staging limitations.
6.5 Titanium 2-P1ySystem:
6.5.1 The Titanium 2 -Ply System consists of a base layer of Titanium UDL-30 (top -surface primed or sheet inverted)
mechanically attached to the wood roof deck followed by Titanium PSU-301 self -adhered.
6.5.2 Non -Tile Applications:
Install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 6.3 followed by Titanium
PSU-30 in accordance with Section 6.4.
NEMO ETC, LLC Evaluation Report 111980.11.08-R11
Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R10
Titanium Roof Underlayments Revision 11:10/17/2019
Page 7 of 8
I
NEMO I etc.
6.5.3 Nail -On Tile Applications:
For nail -on tile installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with
FRSA/TRi April 2012 (04-12), using Section 6.3 as a guide, and considering the wider sheet width relative to ASTM
D226 felt. Then apply Titanium PSU-30 in accordance with Section 6.4.
Refer to Section 5.8 for the staging limitations.
6.5.4 Foam -On Tile Applications:
For foam -on the installations, install Titanium UDL-30 (tap surface primed or sheet inverted) in accordance with
Section 5.6.1 herein. Then apply Titanium PSU-30 in accordance with Section 6.4
Refer to Table 1A for allowable the adhesives.
Refer to Section 5.6.1 for wind uplift limitations.
Refer to Section 5.8 for the staging limitations.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Contact the manufacturer or the named QA entity for plants covered under Rule 61G20-3 QA requirements. Refer
to Section 4 herein for product & production locations having met codified physical properties specifications.
9. QUALITY
Intertek Testing Services NA inc. — QUA1673; (604) 520-3321
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 111980.11.08-Rll
Certificate of Authorization#32455 6t" EDITION (2017) FOC NON-HVHZ EVALUATION FL11602-RIO
Titanium Roof Underlayments Revision 11:10/17/2019