HomeMy WebLinkAboutTANK SPECS - 11-6-20am
OMMML
Quality Steel Corporation AG/UG Propane Tanks
APPROXIMATE
WATER
CAPACITY
ABOVEGROUND/UNDEGRUUP
DIAMETER HEAD
(OD) TYPE
OVERALL OVER
LENGTH HEIG
*120 wg.
24"
Ellip.
5'-8" 3'
*250 W9.
30"
Heml.
7'-10" 3'-1
*320 wg.
300
Hemi.
9'-7" 3'-1
500 wg.
371/2"
Hemi.
Hemi.
10' 4'-:
16 4'-!
1000 wg.
41"
1450 wg.
461/2"
Ellip.
17'-4" 4'4
100 w .
461/2"
Ellip.
23'-11" 4'-�
LF3ki RE
1450 wg. AND UP
D (AG/UG) VESSEL
DIMENSIONS AND SPECIFICATIONS
1LL
LEG*
LEG**
WEIGHT
**QUANTITY
jT
WIDTH
SPACING
(lbs.)
FULL LOAD
PER STACK
1'-11/2"
2'-101/2"
260
109196
16112
or 3 -11
4'-11"
480
54
9
"
1�.g"
5'
620
45
9
"
12.8"
5'
950
37130
816
1,800
17115
6I5
1
1'-9"
11=7"
2,650
12
4
1"
1'-9"
16'
3,520
8
4
Wmenslons and spec"Wagons shown are approodmate. lndMdual vessels =Y vary
' Leg sp-ating +/. 20. Leg widths and specing M3V vary based on mfg. locatlCM check with Your salesperson for deUgs. 120, 250, 320 w& standard tanks
- no Fames to legs (orte tomr We on request). 500 and 100a wg. standard tanks - 2 hales 16' on center. 14so wg. and up as shown above.
•• full load and stack quakes MY by shWIM tocaftm check wo Your salesperson for details.
General S eciflolo- s
- Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section Vlll, Division 1.
Complies with NFPA S8.
- Rated at 250 psig from -20° F to 125' F. All vessels registered with National Board.
-Two service options available:
Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish
or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite
AGjUG dame.
Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid
applied epoxy primer coat followed by urethane top coat, supplied with steel AG/UG dome.
- All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel.
Updated June 30, 2015
r - '
l 1� i .. • noro�w.�rrei •r11 ••
ri.
•� +
I i� t �I I i •I 11• • `•' I (• ••�! tl l 1' •i l s�!!1 i -+-�, j1s= �ji ,1i•.+
JUT.l A'
•r•
ITz • •T !
ill "'I.1
IF
are
Ll
9WAIL it,
CARM
t
/� ' f
e • � .1
sl��Mi� "tog I{ 1//�'f a wit _ �.• f r
1 list
• f
t
PROPANE CONSTRUCTION NOTES
1. All pipe and fittings above ground and inside building shall be
SCH..40 Galvanized ASTM A120 or AGA approved.corrugated
stainless steel •(C.S.S.T.) pipe. ,
2. All- polypipe and fitb*hgs shall be ASTM D251.3 or ASTM D2517
and shall be b urged -outside underground at a depth of 18" with
warning tape and (racer wire. -
3. All pipe and meter locations are approximate and subject to -
change.- -
.4. All polypipe shall be joined by heat fusion or approved mechanical .
couplings.
5. All'galvantzed p1pe shall be threaded.
6: A. pipeL shall be pressure tested to 20 PSI fot a period of 24
hours.
00010" - -
rid
UNDERGRO
uivd -TANK
INS'rALLAVON j
rj�•jj
•
DOWNGRADED AWAY
:
••
•
FROM DOME
• �•
�-•'
/ •
•�
•r
,'-i _ -" �''
•� • L •� I
mI
E ANODE CABLE
' • �•
•• • •
'
• -
SACRJFICiAL ANODE
:-.•�5• • .:
;• .• •
"
(MAGNESIUM 8A9)
-1
• rS
. ft i
•
•
�_ -
REGEM&TOR
�.t.
•
•
-
SIIUT DAS OFF AT
Q IVE
•
IN A60 YEGRADE
•
•
is o
Y
•
WARN Irc TAPE
• ..... ..
• • RISE
'
GRADE/CONCRETE . SIZEYfi
L
maw"•
�•O ...., . .• f•fe
e
4p
•. .
t I.I a
IF
• p • �"p p I •
•
f do•
•.�•+•� •• I • : I 0•f.
ga
•ors
•I-r
.
.. .. ••
••
r •-
",o -
SERVICE LIN�E
.m
° uHoenoaourro tr•o�S
..
CORTM t n
- -
•
TRACE NIRi