Loading...
HomeMy WebLinkAboutFl Product approval 30 lb felt NOA: 18-0409.06 Expiration Date: 03/28/23 Approval Date: 05/10/18 Page 1 of 6 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Gardner Asphalt Corporation 4161 W. 7th Avenue Tampa, FL. 33605 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Gardner Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 17-1221.15 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. NOA: 18-0409.06 Expiration Date: 03/28/23 Approval Date: 05/10/18 Page 2 of 6 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Underlayment Material: Asphalt TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Specification Product Description APOC Tuff-Felt 26 Manufacturing Location #1, 2 36” x 72’ rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 2 square #30. United FGUR20 Manufacturing Location #1, 2 36” x 72’ rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 2 square #30. APOC 25 Manufacturing Location #1, 2 36” x 72’ rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 2 square #30. No. 30 ASTM Manufacturing Location #1, 2 36” x 72’ rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 2 square #30. APOC Tuff-Felt 46 Manufacturing Location #1, 2 36” x 144’ rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment, 4 square #15. United FGUR10 Manufacturing Location #1, 2 36” x 144’ rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment, 4 square #15. APOC45 Manufacturing Location #1, 2 36” x 144’ rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment, 4 square #15. No. 15 ASTM Manufacturing Location #1, 2 36” x 144’ rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment, 4 square #15. United FGUR70 Manufacturing Location #1, 2 18” x 72’ rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 1 square #30. NOA: 18-0409.06 Expiration Date: 03/28/23 Approval Date: 05/10/18 Page 3 of 6 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Specification Product Description GatorSkin Manufacturing Location #3 42” x 285.8’ rolls ASTM D 226 Type II Synthetic roof underlayment comprised of layers of polyolefin film. GatorSkin-10 Manufacturing Location #5 42” x 285.8’ rolls ASTM D 226 Type II Synthetic roof underlayment comprised of layers of polyolefin film. Weather-Armor CX-L Manufacturing Location #3 37.25” x 145’ rolls ASTM D 226 Type II High strength hybrid underlayment comprised of two layers of polyolefin and polyester synthetic fabric with a thin layer of modified bitumen between the two plies. Weather-Armor SB-1 Manufacturing Location #4 36” x 65’ 8” rolls ASTM D 1970 Glass fiber reinforced, polymer modified asphalt, granulated self-adhered underlayment. Gard-Lock Manufacturing Location #4 36” x 65’ 8” rolls ASTM D 1970 Glass fiber reinforced, polymer modified asphalt, granulated self-adhered underlayment. Weather-Armor HT3 Manufacturing Location #4 39” x 65’ 8” rolls ASTM D 1970 60-mils thick (nominally), self-adhering membrane composed of elastic polymers, bitumen, glass reinforcements and a cross laminated sheet surfacing. Weather-Armor FT3 Manufacturing Location #4 39” x 65’ 8” rolls TAS 103 60-mils thick (nominally), self-adhering membrane composed of elastic polymers, bitumen polyester and glass reinforcement. MANUFACTURING LOCATIONS: 1. Tacoma, WA. 2. Eutaw, AL. 3. Hangzhou, China. 4. Springville, AL. 5. Tampa, FL. NOA: 18-0409.06 Expiration Date: 03/28/23 Approval Date: 05/10/18 Page 4 of 6 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials GGI-100-02-01 ASTM D 226 06/22/12 Technologies GGI-101-02-01 ASTM D 226 06/22/12 GGI-132-02-01 ASTM D 226 04/28/15 GGI-176-02-01 ASTM D 226 09/26/16 GGI-178-02-01 ASTM D 1970 10/25/16 GGI-194-02-01 ASTM D 1970 08/04/17 GGI-196-02-01 TAS 103 08/08/17 GGI-206-02-01 ASTM D 226 03/09/18 GGI-207-02-01 ASTM D 226 03/09/18 GGI-201-02-01 ASTM D 1623 01/29/18 GGI-178-02-01 ASTM D 1970 01/29/18 GGI-178-02-02 ASTM D 1970 01/29/18 GGI-199-02-02 ASTM D 226 12/12/17 APPROVED ASSEMBLIES: Deck Type 1: Wood, Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened to deck. Anchor Sheet: One or more plies of APOC Tuff-Felt 26, United FGUR20, United FGUR70, APOC 25, No. 30 ASTM, GatorSkin, GatorSkin-10 or Weather-Armor CX-L with a minimum 4” headlap and a 6” end lap mechanically fastened to deck with approved nails and tin caps 6 inches o.c. minimum at all laps and three staggered rows fastened at 12 inches o.c. minimum in the field of the roll. Nails shall be driven flush and 90 degrees to the roof deck. Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, metal roof applications, and as an anchor sheet in roof tile applications. Must Comply with applicable Roofing Application Standards and Building Codes. Deck Type 1: Wood, Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(2): Anchor sheet mechanically fastened to deck. Anchor Sheet: Minimum 2 plies or more of APOC Tuff-Felt 46, United FGUR10, APOC 45, or No. 15 ASTM with a minimum 19” headlap and a 6” end lap mechanically fastened to deck with approved nails and tin caps 6 inches o.c. minimum at all laps and three staggered rows fastened at 12 inches o.c. minimum in the field of the roll. Nails shall be driven flush and 90 degrees to the roof deck. Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, metal roof applications, and as an anchor sheet in roof tile applications. Must Comply with applicable Roofing Application Standards and Building Codes. NOA: 18-0409.06 Expiration Date: 03/28/23 Approval Date: 05/10/18 Page 5 of 6 Deck Type 1: Wood, Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(3): Anchor sheet mechanically fastened to deck, membrane adhered. Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4” headlap and a 6” end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Membrane: One or more plies of Weather-Armor SB-1, Gard-Lock, or Weather-Armor HT3 self-adhering membrane adhered to the anchor sheet with a minimum 3” headlap and 6” end lap. Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, and metal roof applications. Must Comply with applicable Roofing Application Standards and Building Codes. Deck Type 1: Wood, Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(4): Anchor sheet mechanically fastened to deck, membrane adhered. Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4” headlap and a 6” end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Membrane: One or more plies of Weather-Armor FT3 self-adhering membrane adhered to the anchor sheet with a minimum 3” headlap and 6” end lap. Surfacing: • Weather-Armor FT3 Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, metal roof, and mechanically fastened roof tile applications. • Weather-Armor FT3 may be used with any approved adhered roof tile system as specified in their current NOA using the following tile adhesives with current NOA: The Dow Chemical Company’s TILE BOND Roof Tile Adhesive ICP Adhesives and Sealants, Inc.’s ICP Adhesive Polyset AH-160 Must Comply with applicable Roofing Application Standards and Building Codes. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. NOA: 18-0409.06 Expiration Date: 03/28/23 Approval Date: 05/10/18 Page 6 of 6 BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Weather-Armor SB-1, and Weather-Armor HT3 shall not be hot mopped; refer to manufacturer’s published literature for product compatibility. 4. Gardner Underlayments listed herein are components used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance. 5. APOC-Tuff Felt 26, United FGUR20, APOC 25, No. 30 ASTM, APOC-Tuff Felt 46, United FGUR10, APOC 45, No. 15 ASTM, United FGUR70, GatorSkin, GatorSkin-10 and Weather Armor CX-L listed herein shall not be left exposed as a temporary roof for longer than 30 days of application. 6. Gard-Lock and Weather Armor SB-1 listed herein shall not be left exposed as a temporary roof for longer than 90 days of application. 7. Weather-Armor HT3 and Weather-Armor FT3 listed herein shall not be left exposed as a temporary roof for longer than 180 days of application. 8. Gardner Underlayments listed herein may be used with any approved roof covering Notice of Acceptance listing Gardner Underlayments listed herein as a component part of an assembly in the Notice of Acceptance. If Gardner Underlayments listed herein is not listed; a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 9. For fire classification of specific roof assemblies using Gardner Underlayments listed herein refer to a current Approved Roofing Materials Directory for fire ratings of this product. 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE