Loading...
HomeMy WebLinkAboutConstruction Plansr� SETUP AND INSTALLATION OF SINGLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BUILDING IS BLOCKED ON THE HIGH SPOT AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED. 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLED THRU THE 2"x4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. 6. IF THE UNIT HAS A FLOOR. EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE 1-1/2" OFF OF RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT IS A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. TABLE 1 ANCHORING TO CONCRETE SHED WIDTH UPLIFT (PLF) ANCHOR SPACING 20'-0" 400 3'--6" 13'-8" 280 3'--6" 240 10'-0" 200 3 160 3� 6'-0" 120 3 TABLE 2 SKID RUNNER SPACING* SHED WIDTH X1 X2 X3 13'-8" V-104" 1'-10)• V-10}" 11'-8" 2'-8" 6'-4" - 10'-0" V-7" 6'-10" - 8'-0" 0'-9" V-6" - 6'-0" 0'-10" 51" - •VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4'x4' SKIDS ONLY. 13'-8" WIDE SHEDS HAVE (4) SETS OF SKIDS. r 30- CHOR .INSTALLED P R, MANUFACTURER'S INSTRUCTIONS'., AT MAxIMuM"OF56" ABOVE GRADE. SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE01� T PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL Ng,Tlik C BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (S T-ABL-E 3� 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1 �-x44" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. TABLE 3A. PAD TYPES TYPE PAD DIMENSIONS MAX. LOAD* MATERIAL I 2"x8"x16" 1778LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX II 4"x8"x16" 3500LBS CO CREPE BLOCK QUALITY CEMENT AND SAND MIX III 16"0 6" 3950LBS ABS PLASTIC PADS IV 8"x8"x16" 1900LBS CO CRETE BLOCK QUALITY CEMENT AND SAND MIX • BASED ON 2000PSF SOIL BEARING CAPACITY (2000PSF IS TYPICAL) NOTES 1. HOLLOW OR SOLD CONCRETE BLOCKS (EINEINW) MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON 11'-8' AND 13'-8' WIDE SHEDS ONLY. TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS SHED DESCRIPTION PAD MAXIMUM LOAD AND PAD TYPE SHED WIDTH TYPE LW(PLF) END PAD MAX. SPACING END PAD SIDE RUNNER PAD TYPE INTERIOR PAD SIDE RUNNER PAD TYPE 13'-8" SW/DW 4.15/332 0" TO 6" 6'-0" 1936LB I, II, III, OR IV 1879LB I, II, III, OR fV 11'-8" SW/DW 6.00/480 0" TO 6' 6'-0" 2558LB I, II, III, OR IV 25581_8 I, II, III, OR IV 10'-0" SW/DW 5.00/400 0" TO 6' 6'-0" 2400LB I, II, III, OR fV 2400LB I, II, III, OR N 8'-0" SW 4.00/320 0" TO 6' 6'-O" 2029LB I, II, III, OR IV 2133LB I, II, III, OR IV 6'-0' SW 3.00/240 0" TO 6' 6'-0" 1658L8 I, II, III, OR IV1866LB I, II, III, OR N • LOAD WIDTH OF UPLIFT ON RUNNER NOTES 1. PAD SPACING IS END TO CENTER OF PAD. 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER. 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING. GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED PORTIONS OF SHEDS ON LEVELING BLOCKS. TABLE 4A 30" AUGER ANCHOR SPACING - SINGLE WIDE SHED WIDTH LW UPLIFT (PLF) END ANCHOR" MAX. INTERIOR SPACING- 13'-8" 7.00 243 0'-0" TO N-W 10'-O" 11'-8" 6.00 208 O'-0" TO S-O" 10'-O" 1LP 04 0 ` i', 174 ! 0'-0" TO 3'-0" 10'-0" 8'-0"L- �4.00 138 O'-0" TO S-O" 10'-0" 6'-0" 3.00 104 0'-0" TO S-O" 10'-0" TABLE B 30" AUGER ANCHOR SPACING - DOUBLE WIDE SHED WIDTH LW UPLIFT (PLF) END ANCHOR" MAX. INTERIOR SPACING*** 20'-0" 10.00 400 0'-0" TO S-0" 1 5'-0' • LOAD WIDTH OF UPLIFT ON RUNNER •• LOCATION FROM END WALL OF AUGER ANCHOR ••• MAXIMUM SPACING BETWEEN ANCHORS NOTES 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7. 2. ALL MEASUREMENTS ARE CENTER -TO -CENTER. 3. THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER. ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0" BETWEEN ANCHORS.. 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN EXISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE SIDE AS POSSIBLE. b tb- F_VIF CODE COMi6l ST. L UCIE CO *Jj 2"x2' GALVANIZED WASHER % 2•x2" GALVANIZED WASHER WITH 1/2' NUT 1/2' THREADED ROD 'HIGH ���� WTI►{ 1/2• NUT � Ia OPTIONAL FOR SET' NOTCH OR COUNTERSINK BOLT 1/2' THREADED ROD G „ ' OPTIONAL FOR 'HIGH SEi /<< 1/2' COUPL/!� % EYES BOLTED TOGETHER WITH 1/2'x2' BOLT k NITr WITH (2)2'x2' GALVANIZED WASHERS (2.000LB SHEAR CAPACITY) 11 COUPLER - 1/2'x5" 400 LB. CONCRETE THRU 2°x4' BOTTOM PLATE Z: 2'x4' BOTTOM PLATE NAILED TO 2'x6' P.T. BASE 1/2'x12' FORGED EYEBOLT 9 Li-' '�"` C� e f° L • e a , y �b r '' n' ; . ' • . -MIN. o • WEDGE ANCHOR INTO SLAB THRU 2"x4' P.T. BOTTOM PLATE (SEE TABLE 1 FOR SPACING) MIN. -----=- - o EYES BOLTED TOGETHER WITH %�2"x2" BOLT k NUT WITH (2)2'x2 GALVANIZED F� TYPE`INb,5A, OR I PAD WTIH WASHERS (WITH (B SHEAR CABACfTY)" BLOCKINGrAS REQUIRED (SEE TABLE 3). 1/2'x3' (400 LB.) SIMPSON A-74 CONCRETE SLAB BY OTHERS THROUGH CONCRkS11 OTHERS THROUGH C,.r 30' EARTH AUGER ANCHOR r- ' CONCRETE WEDGE ANCHOR (SEE TABLE 1 FOR SPACING) CLIP OR EQUAL LOCAL CODES AND JURISDICTION LO D JURISDICTION (SEE TABLE 4 FOR SPACING) OSH' ED�WITiHSrKID ANCHORED SHED WITH SKID TO CONCRETE SHED ANCHORED WITH 'NO FLOOR" OPTION TO CONCRETE P"i4D�.A0R-_BLOCKING TIE -DOWN DETAILS CODE VERSION FBC 2017 5N EcI lon. A9CE-7 MANUFACTURER SUPERIOR SHEDS BUILDING TYPE R6mF U ILDING STORAGE CONSTRUCTION TYPE V-e FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE ALLOWABLE NUMBER OF STORIES I 1 ::�i BASIC WIND SPEED I v IBOm"h ENCLOSURE ENS, rm,. INTERNAL. PRESSURE COEFFICIENT +/- (L15 IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 2OPSF OR MOM. FLOOR DEAD LOAD 8PSF FLOOR LIVE LOAD STD. 76PSF - 125PSF OPT. •R' RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE No SQUARE FOOTAGE I LESS THAN 720 SOFT. REVISIONS REV I DESCRIPTON I DATE I BY 1 2017 MG 11/12/17 MTe 2 1 GROUND ANCHOR 6' A .G MAX, ANCHOR Ex V=N 5/26/1e MITI (/) 0 LLJ U) LLI 0 W_ J m R0 TLY Z LLJ ALL GENERAL NOTES I. FOUNDATION PLANS ARE NOT PART OF THIS PLAN SET AND ARE GOVERNED BY LOCAL JURISDICTION. 2. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION 1015.22. 3. REFER TO TIE -DOWN DETAILS FOR PROPER INSTALLATION REQUIREMENTS TO MEET CODE. 2/5/20 Cam= attheW T. Bdllawin P!E �i,eFlonda Lice�ss �64608 Sheet: AD- gI OF 2018-12-20 TOP LINE ENGINEERING APPROVAL PLAN #SS-B-180-C Side Wall Header Schedule (180C) End Wall Header Schedule (180C).._> Fasteners w/o strap r x, Building Width Size{d) Max. Span NJ(b) (each endxct u� D4 ALUMINUM ROOF SHEATHING Fasteners w/ strap - Size Up to 14' Wide 1-7'x4" 6-0' 0 4- 3' x 0.131' nails --..-- _.... ......... ... ...__. (each end) 3t' - ,—11-11-11, ,..�.. _ I 0 -0 MAX- I Ir) 0 I x RUNNERS 0 I w END W TRUSS 2"x4" TRUSS @24" O.C. DESIGN PRESSURES ROOF FRAMING PLAN ROOF +27.8 -94.7 ILLS/DOORS/ INDOWS +32.6 -29.2 Max. Span NJ{b} 2-Zk4 (c) 9' D D{d} 6-3 x 0.1 naps 1-0"X4" 6'-0" D 3 - 3° x 0.131 °nails a. Tabulatetl values an: for No. 2 grade Spruce -Pine -Fir lumber. b. NJ - Numberofjack studs required to support each end. 4"x4° w2"x4" 8'-0" c. 1 6 - 3' x 0.134' nails Laid flat �— A� a. Tabulated values are for No. 2 grade Spruce -Pine -Fir lumber. ) , d. No Jack studs, but 2x6 studs laid flat. 21" b. NJ -Number ofjack studs required to support each end. c. Window header for window openings that hake more than 50% combined stud wall abovey sa and below, otherwise use door header schedule. -NOTES 1. SEE FASTENER SCHEDULE FOR HARDWARE IREMFMS, d. See header details for aftemate layouts, i.e. 2-2"x4" or 4"x4" P.T. a SEE saHmuLEFDR� ADOMg, ar fAnat, 3. HEADERS FIVE COUB)NED 0W OR aE WALL FRAMING ABOVE e. The header can be attached to the top plate and thus have the combined strength �, GTE1W Z REFER 10 DOM HEADERS. CODE INFORMATION equivalent and use the maximum span stated. CODE VERSION FBC2of201177 61H �" ASCE-7 MANUFACTURER SUPERIOR SHEDS WALL MUDS BUILDING TYPE MANUFACTURED BUILDING RESIDENTIAL LASTORM•E " CONSTRUCTION TYPE V-B 'I 'i SHETTING HEADER FIRE PROTECTION NONE �' I '' FIRE SUPPRESSION SYSTEM NONE j ' i' (2) 2•x4• WOH 1/2• PLYWOOD - OR OSS RU.ER OR (1)4•.4• 2'IW OCCUPANCY STORAGE I 12'x1T OR 16'x4• BE1*UN 4'x4' ALLOWABLE NUMBER OF STORIES 1 '� wALL �ixac �PEa �� 12` MAX MANUFACTURERS aSmucnoNs Basic WIND SPEED Var,eornph HYDROVENT DETAIL SIDE WALL WINDOWS END WALLS WINDOWS & EXPOSURE c (OPTIONAL & DOORS DOOR 6' WIDE OR LESS 4"x4" �/2"x4" ENCLOSURE ENCLOSED INTERNAL PRESSURE cOEFFlCIENr +/- O.,B IMPORTANCE FACTOR 1.16 ROOF DEAD LOAD 1OPSF OTES OUTLET N-OPTIONAL ELECTRIC ROOF LIVE LOAD 3OPSF OR 300Ib POINT LOAD Tor 11NE Evrav>:rm�a cu FLOOR DEAD LOAD 1OPSF -ALL WIRING SHALL BE 14 GAGE 3-WIRE MC CABLE. ixfi3OaALtT'trw N t F -ENCASE IN ALL METAL BOXES. William E. Neary, III FLOOR LIVE LOAD SID. 76PW - 125PSF OPT. SOURCE - SFAP-5S1,41-79, ICC 5:E5040 W RATING OF WALLS, FLOOR, ROOF N/A L LL WIRING DIAGRAM 10649 Oakvierr Pointe Terrace (OPTIONAL) Gotha, Florida 34734 MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO 2W - END WALL DOOR & WaDOW LocAnoNs VAFO' SQUARE FOOTAGE 719 so -Fr. . OR LE OR �R�NE a REVISIONS r:< DouAR OR OR AURNE z• ,. E�tD DETAIL, REV DESCRIPTON DATE BY QUAL I 4a I � i � / i D4 Aw)INUM WALL � / � / � � sHFAn9Nc OPTIONS Ira• MAx I,IA1L zx4 �. OG SEE HEADER DETAIL g / / 1z4 RUNNER ONINSmE LLI DmYNn By. MTB 2:4 / ENDEMA.L. J Dote: 12/12/17 / WAL O SCOIG N A 2x4 STUDS O SOLE PWE Cn u = MAIL r=111D R FRAMNG g Cn SS-B-180C 2z4 SOLL: PIATE L4 SOLE PLATE 1. FO WON ARE NDT PART OF THIS PLAN SET AND ATE FLOOR FRAMING LLI STUDS SECURED TO EDIF PLATE LLJ J 2. 7H LANGLgCADLM NPr FROM THE FBC ENERGY CONSTAVATION CODE PER sEan 1D16.Z2 AND FLOOR FRAMING WDH O.W9' a_ 3. REFER TO ,E- DETALS FOR PROPER INSTALLATION LJ LJ x LJ x LJ (1mm)x12 STRAP W/B-10A NAILS STANDARD WALL DETAIL OR EQUAL NOTE WALL FRAMu+G MEifBETss ARE GarmN"D s FROM FTXINWRON SILL ro ROOF AND s�aLL� Tp ENAIFE A ¢ REaD'REaNE+ts To CODE 4. ALL STOW, RAFTERS, TRUSSES. ETC. ARE 2x4 #2 SPK EXCEPT uNs 6 O ro is e' AaFs FLOOR SHFATHa� WITH DOOR & WINDOW OPTIONS CON INUOW LOAD PATH WHETaE WALL NEx1eER5 ARE O As NmFJI. 6'-o ro t3�• _ 3/4• PLVWOOD Nor CONTINUOUS, SHEET META- PS, TI S, OR CLIPS SHALL BE FORMED OF G&VAN® STEEL OF Nor LESS U B. STRUCTURES OVER 400 SG Fr. WILL HAVE AN BO• MINIMUM ELEVATION CROSS—SECTION END ELEVATION 4514• ATTALEW. WITH - 3/4' P.T. PLYWOOD - 3/4' T&0 THAN 0.040• NoMNAL,IDawES4 LLl DOOR 6. GUTTERS TO BE INSrALLED ON -SITE BY OTHERS THRU LOCAL TYPICAL ARCH FRAME WITH DOOR R E FIz4 OR EOUNQUANT SEE TAaLE 2 FOR NxLANRIr AND SPICNc. - 3/4• P.T. T&G LLj IZ 7. 9 00ND0*S AND Doan 1. MEET THE MINIMUM SPECmb1TIONS �' MAx Cn O a MPER FLORIDATNABULDDIINNGIg ODE. AROUND STRUCTURAL MEMBERS 4F )TVA L &TLros. TRUSSES, awr+os, ETC._ To -HELP SECURE THESE g2.12X w2x4 LAnFw " ---- ---- -- --- ---- -- --- -_-- __-- --- __-- __-- -- --- SHED 41mH TABLE x1 2 SPACING - xx xS -7rr a- YRVYISTII i I THE N]oF1J BEAD WFS RDt INIFRFtw *ANY TTH1 I A fO! G BRAKE: BQ W 1! TINE STRAP. EXISTING `�P� :' ••�10ENSE••••'C%�i� 's v�� 6a-G� o- _ VK ES AM FKM 00 Or JmT TO GOEM Or LT) AW 905 •� i 9 w O19 1S-e• om 9E>a DUc (4) 4 OrLLJ = 2x4 Tam I P 2d TnOa4Nc 4 ; Q g 2•x1r TAD FLAT' = = I 2x6 P.T. 24' TP. OPTIONAL OONAL 126PW PSF O 16. O.C. .c - �. STATE .: � TM WTm 3/4' T&G PLYIEGUM I / \ / 0'•. OF •'• F 2,4 SOLE RATE f]", 4•x4' P.T. ATTACHED *M aEaDNAEM. SEE -i �` L 0 RION ' FLOOR FRAMNc 9. UAX_E ULLL 7H7A I TA13LE 2 FOR QUANTITY AND O •. •�` ; ``�� ' /0 C� N A.� OJT LJ LxJ LxJ ' I Matthew T. Baldwin P.E. Florida License #64608 -VARIES6•-0• TO 15-6 AAES 6•-G' ro ,S-e' -- -- ---- ---- ---- ---- ---- ---- --- ---- ---- ---- -- ---- ---- --- j� --- ---- ---- - --- ---- — __-- __-- __-- — __-- __-- � END ELEVATION END ELEVATION Z Sheet SSB-1 OF 1 WITHOUT DOOR WITH GARAGE DOOR BOOR 'OIST, SFE 5Q1EDULE FOR SUE F (ONLY ON ENAALL) FLOOR FRAMING PLAN m