HomeMy WebLinkAboutLetter; Plan Review Comments3 Rich Properties L.L.C. cad& V b to ap adMteab 1900 Bella Vista Way Port St. Lucie, FL 34952 11/26/01 Mr. William Hatcher Division of Building & Inspections 2300 Virginia Ave. Fort Pierce, FL 34982 RE: Savannah Club Apts. (aka; Bella Vista Apts.) Permit # 21090656 Garages Dear Mr. Hatcher, In response to the attached plan review comments, please find the attached revised plans and the following written response; 1) Page 53.1 reference ........... Agreed - plans have been revised to reference the details on 55.1. 2) Door Buck Fastener Detail... Agreed — Reference note # 9 on 55.1 ( Use 3/16" x 3-1/4" Tapcons, 36" O.C., Stgd.) 3) Roof Shtg. NO Patern ........ Agreed- Reference sheet 53.2 Note 4) 1 Hour Separation ............. Disagree- Ref. SBC 411.2.6 — Since the garages are not connected to other occupancies, 1 Hour separation is not required. Should you have any question concerning the above, please contact.this office at (561) 340-4440 or you can reach me on my cell phone at (561) 708-7876.. Sincerely, VC-C� Richard C. Lundy Project Manager cc: file i