BLOWER DOOR TM FORM
House Ira`ri M-don Test CertValc atior,
Prescriptive and Pei fomanice Method
Date; — I l 'f ]_ oz Permit•'.h: Z o ( — n 2 8
Contractor:Job Address- Z C¢ e L OS P aJ e®-g F— 3 'f�Sj
consiruction- New construction mComplete t IExas'irig—AoterAddlt€on
F?ouse insili:ration rest Results SLC ,linate Zone 2
CFM (So)= 17-IL Test Data: t
Volume= i t 5 6
ACH(50)=CFM (50)a 60 J Volume= b .3 mechanicOl ventiiatfon r egsired less than 3 Act•!
Passing results must be&ACH(50)or less (vf Pass ( ) Fail
Fat,Energy
She building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w.g.(50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or(7),Florida Statutes or individuals licensed as set forth in Section 439.105 (3)(f), (g) or(i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations or, the building
thermal envelope.
e3C,Residential
Where the air Infiltration rate of a dwelling unit is less than 3 air changes per hour When tested with a blower door at a
pressure of 0.2 inch w.c.(50 Pa) in accordance with Section P,402A.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3.
Testing Cornoanv
Company Name: Pro-Duct Services Address: -1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby card,y thatthe above House iinfiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance v�cd �.1.?Climate_one 2.
r
Signature:
Printed Name: Martin Klein
License/Certification a; 5061633