HomeMy WebLinkAboutBlower Door Test Planning_• ©evelopmem Services
Building&Code Regulatilon Division
2300 Virginia Ave,Rm 201
Fort Pierce,FL 34952
e Phone:772-4.62-2265 Far.772-462-6 3
BLOWER DOOR TEe s FORM
Mouse Irir)lgra-don Tess cerd)aaca ion
PrescriWelve and Pgr9ormance NVchod
Date, t 1 �_ S't � Z ' Permit
Contractor:
Job Address:
Construc%ion: J B;lls-dng—ffaier AddNdon
Souse lnfiltratlon Test Pass�14 SLC Unnate lone 2
CFM (50)_ ( 3 3 �— Test Date: r L
Volume= u 5 6 9 / Q
ACH (50)=CFM(50)n 601 Volume= v l Mac ar+ical Ventilation required less zhon 3 ACHI
Pass
ing results must be&ACH(50)or less Gass ( ) Fail
F 6C,Energv
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a
blower door at a pressure o;"0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5)or (7),Florida Statutes or individuals licensed as set f orth in Section A89.105 (3)(,, (g) or(i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. i esting shall be perormed at any time a ter creation of all penetrations of the building
thermal envelope.
=c'Resldenfti
Jdilere the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of'0.2 inch w.c.(50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3.
Testing Comnanv
Company Name: pro-Duct Services Address: 1995 Rio Vista Drive, rt. Pierce, FL 3^^—.9a9
1 hereby certify thatthe above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in acc?7�=
02.4.1.2 Climate Zone 2.
Signature:
Printed Name: Martin Mein
License/Certification#: 5061633