SLOWER DOOR TEa i MPH
House inTfitration Test CerIi$ication
Preser0dpie and Peeformance Method
Date, if ,/ 2°LO Permit#: Z 0"r
Contractor: w Na e 1/Rra
io�l5dciressc i $8 �a �f � d� L-ayrys �fi �e��t, FI_ 3 `Fgsl
Ca'9.nstr€action: ' 4 New Construction —corn 9lete F:=iscirag—Aa Ler Addidon
House Infiltration Test Results SLC climate Zone 2
CFM (50)_ Ki S b Test Late:_ l( 1 512-.t-o
Volume= 10 >-1 6 •-L
ACH (50)=CFM(50)n 60/Volume= Mechoniccl ilentiiaiion required less then,3:1CM
Passing results must be&ACH(50)or less (V`?ass ( ) Fail
I
F6C,Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w.g.(50 Pascals). Ti esting shall be conducted by either individuals as defined in
Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or(i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation as all penetrations of the building
thermal envelope.
r esicien ial
Where the air tnfiiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c.(50 Pa) in accordance with Section P.402-4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3.
Testiniz Companv
Company Name: Pro-Duct Services Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
1 hereby certify that the above House Infiltration results demonstrate compliance with FSC Energy Conservation
requirements in accords ce with 5 cd n R402.4.12 Climate%one 2.
Signature: Illy
Printed Name: Malin Klein
License/Certification=: 5061633